Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Anal Biochem ; 611: 113953, 2020 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-32946834

RESUMO

Conjugated proteins and enzymes are often formed using N-hydroxysuccinimide (NHS) chemistry, which reacts with free primary amines resulting in a loss of charge and a reduction in isoelectric point (pI). Measurement of the extent of reaction of these conjugates is critical for biopharmaceutical developers. Due to this change in protein charge state, denaturing capillary isoelectric focussing (cIEF) offers a potentially straightforward and convenient approach for extent-of-reaction quantification. Here, we demonstrate the potential of this technique with poly(ethylene glycol) (PEG) conjugates of Erwinia chrysanthemil-asparaginase (ErA). Development of an appropriate sample preparation technique is critical to achieving reproducible cIEF electropherograms, particularly for denaturation-resistant proteins such as ErA, and an emphasis was placed on this during development of the PEG-ErA cIEF method. cIEF electropherograms demonstrating a distribution of PEGylation states in a bell-shaped curve were obtained, and assignment of PEGylation states to these peaks was critical to routine use of the method. The method is sensitive enough to resolve non-lysine adducts of PEG (such as those conjugated to histidine residues) and was shown to give reproducible results over a 2 year period. Biopharmaceutical developers should consider cIEF for extent of reaction monitoring and measurement for conjugates of free amine groups.


Assuntos
Asparaginase , Proteínas de Bactérias , Dickeya chrysanthemi/enzimologia , Polietilenoglicóis , Asparaginase/análise , Asparaginase/química , Proteínas de Bactérias/análise , Proteínas de Bactérias/química , Eletroforese Capilar , Focalização Isoelétrica , Polietilenoglicóis/análise , Polietilenoglicóis/química
2.
J Chromatogr A ; 1317: 148-54, 2013 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-24011724

RESUMO

In this work, the suitability of employing shallow pH gradients generated using single component buffer systems as eluents through cation-exchange (CEX) monolithic columns is demonstrated for the high-resolution separation of monoclonal antibody (mAb) charge variants in three different biopharmaceuticals. A useful selection of small molecule buffer species is described that can be used within very narrow pH ranges (typically 1 pH unit) defined by their buffer capacity for producing controlled and smooth pH profiles when used together with porous polymer monoliths. Using very low ionic strength eluents also enabled direct coupling with electrospray ionisation mass spectrometry. The results obtained by the developed pH gradient approach for the separation of closely related antibody species appear to be consistent with those obtained by imaged capillary isoelectric focusing (iCE) in terms of both resolution and separation profile. Both determinants of resolution, i.e., peak compression and peak separation contribute to the gains in resolution, evidently through the Donnan potential effect, which is increased by decreasing the eluent concentration, and also through the way electrostatic charges are distributed on the protein surface. Retention mechanisms based on the trends observed in retention of proteins at pH values higher than the electrophoretic pI are also discussed using applicable theories. Employing monolithic ion-exchangers is shown to enable fast method development, short analysis time, and high sample throughput owing to the accelerated mass transport of the monolithic media. The possibility of short analysis time, typically less than 15 min, and high sample throughput is extremely useful in the assessment of charge-based changes to the mAb products, such as during manufacturing or storage.


Assuntos
Anticorpos Monoclonais/química , Anticorpos Monoclonais/isolamento & purificação , Cromatografia por Troca Iônica/instrumentação , Cromatografia por Troca Iônica/métodos , Anticorpos Monoclonais/análise , Soluções Tampão , Concentração de Íons de Hidrogênio , Focalização Isoelétrica/métodos , Espectrometria de Massas , Concentração Osmolar , Polímeros , Proteínas Recombinantes/análise , Proteínas Recombinantes/química , Proteínas Recombinantes/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa