RESUMO
BACKGROUND: Dengue is a global public health challenge which requires accurate diagnostic methods for surveillance and control. The gold standard for detecting dengue neutralizing antibodies (nAbs) is the plaque reduction neutralization test (PRNT), which is both labor-intensive and time-consuming. This study aims to evaluate three alternative approaches, namely, the MTT-based (or (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) microneutralization assay, the xCELLigence real-time cell analysis (RTCA), and the immuno-plaque assay-focus reduction neutralization test (iPA-FRNT). METHODS: Twenty-two residual serum samples were tested for DENV-2 nAbs using all four assays at three neutralization endpoints of 50%, 70% and 90% inhibition in virus growth. For each neutralization endpoint, results were compared using linear regression and correlation analyses. Test performance characteristics were further obtained for iPA-FRNT using 38 additional serum samples. RESULTS: Positive correlation of DENV-2 neutralization titers for the MTT-based microneutralization assay and the PRNT assay was only observed at the neutralization endpoint of 50% (r = 0.690). In contrast, at all three neutralization end points, a linear trend and positive correlation of DENV-2 neutralization titers for the xCELLigence RTCA and the PRNT assays were observed, yielding strong or very strong correlation (r = 0.829 to 0.967). This was similarly observed for the iPA-FRNT assay (r = 0.821 to 0.916), which also offered the added advantage of measuring neutralizing titers to non-plaque forming viruses. CONCLUSION: The xCELLigence RTCA and iPA-FRNT assays could serve as suitable alternatives to PRNT for dengue serological testing. The decision to adopt these methods may depend on the laboratory setting, and the utility of additional applications offered by these technologies.
Assuntos
Anticorpos Neutralizantes , Anticorpos Antivirais , Vírus da Dengue , Dengue , Testes de Neutralização , Sorogrupo , Ensaio de Placa Viral , Vírus da Dengue/imunologia , Anticorpos Neutralizantes/sangue , Anticorpos Neutralizantes/imunologia , Humanos , Testes de Neutralização/métodos , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Ensaio de Placa Viral/métodos , Dengue/imunologia , Dengue/diagnóstico , Dengue/virologiaRESUMO
BACKGROUND: Patients recovering from COVID-19 may need vaccination against SARS-CoV-2 because acquired immunity from primary infection may wane, given the emergence of new SARS-CoV-2 variants. Understanding the trends of anti-spike IgG and neutralizing antibody titers in patients recovering from COVID-19 may inform the decision made on the appropriate interval between recovery and vaccination. METHODS: Participants aged 20 years or older and diagnosed with COVID-19 between January and December, 2020 were enrolled. Serum specimens were collected every three months from 10 days to 12 months after the onset of symptom for determinations of anti-spike IgG and neutralizing antibody titers against SARS-CoV-2 Wuhan strain with D614G mutation, alpha, gamma and delta variants. RESULTS: Of 19 participants, we found a decreasing trend of geometric mean titers of anti-spike IgG from 560.9 to 217 and 92 BAU/mL after a 4-month and a 7-month follow-up, respectively. The anti-spike IgG titers declined more quickly in the ten participants with severe or critical disease than the nine participants with only mild to moderate disease between one month and seven months after SARS-CoV-2 infection (-8.49 vs - 2.34-fold, p < 0.001). The neutralizing activity of the convalescent serum specimens collected from participants recovering from wild-type SARS-CoV-2 infection against different variants was lower, especially against the delta variants (p < 0.01 for each variant with Wuhan strain as reference). CONCLUSION: Acquired immunity from primary infection with SARS-CoV-2 waned within 4-7 months in COVID-19 patients, and neutralizing cross-activities against different SARS-CoV-2 variants were lower compared with those against wild-type strain.
Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Anticorpos Neutralizantes , Soroterapia para COVID-19 , Imunoglobulina G , Anticorpos AntiviraisRESUMO
OBJECTIVE: Reliable high-throughput serological assays for SARS-CoV-2 antibodies present an important role in the strength and duration of immunity after vaccination. The study investigated the analytical and clinical performances of neutralizing antibodies (NTAb) assay by chemiluminescent (CLIA), and SARS-CoV-2 neutralizing antibody after vaccination in real world. METHODS: The analytical performances of CLIA for SARS-CoV-2 NTAb were evaluated, followed by the sensitivity and specificity identified with a PRNT test from 50 volunteers. Then, a cohort of vaccine recipients (n = 37) were tracked with SARS-CoV-2 NTAb assay at prior to vaccination, one, three and six months post two doses. In real world, a total of 737 cases were recruited from physical examination center in Shenzhen Luohu People's Hospital (from Jun to August 2021) to analyze vaccination status. RESULTS: Serological assays on the CLIA were found with excellent characteristics including imprecision, repeatability and linearity. Besides, it was robust to icterus, lipemia and hemolysis. The good sensitivity and specificity were obtained at 98% and 100%, respectively. NTAb results showed a high correlation with PRNT50 titers (r 0.61). Until July 2021, the BBIBP-CorV (76.3%) and Sinovac CoronaVac (20.5%) were the predominant vaccines injection in Shenzhen, China. Adolescent less than 18 years was the main unvaccinated group (52.1%). The seropositive rate of inactive SRAR-CoV-2 vaccines exceeded 97% after inoculation. The NTAb generated by Sinovac CoronaVac with the schedule of 0-56 days was found significantly lower than that by BBIBP-CorV (P < 0.001). The follow-up of NTAb changes in a cohort and the dynamic variation of NTAb in real world disclosed steep downward by almost three times for NTAb level occurred at three months post twice vaccinations. The seropositive ratio was at least 50% over 6 months. CONCLUSIONS: SARS-CoV-2 neutralizing antibodies assay show excellent analytical and clinical performances, and a high correlation with neutralizing activity. Anti-epidemic measures and the urgent trial of SARS-CoV-2 vaccine was calling for adolescents.
Assuntos
Vacinas contra COVID-19 , COVID-19 , Adolescente , Anticorpos Neutralizantes , Anticorpos Antivirais , Humanos , Luminescência , SARS-CoV-2 , VacinaçãoRESUMO
INTRODUCTION: In regions where the endemic measles virus has been eliminated, early detection of contagious patients is important for preventing the spread of measles and sustaining elimination. To investigate whether serological assays can be used for the estimation of highly infectious patients with measles, we performed a seroepidemiologic study of a measles outbreak in Yamagata Prefecture, Japan, in 2017. METHODS: We tested plaque reduction neutralization (PRN), IgG avidity, and gelatin particle agglutination (PA) assays in 31 patients with measles, subdivided into two super-spreaders, three spreaders, and 26 non-spreaders. Simultaneously, these results were compared with the cycle threshold (Ct) of a semi-quantitative real-time reverse transcription PCR for the measles virus from throat swab specimens. RESULTS: In the PRN assay, one super-spreader and two spreaders lacked protective antibodies. The IgG avidity assay showed that two super-spreaders and one spreader had low avidity. The PA assay indicated that two super-spreaders and two spreaders lacked protective antibodies. Comparison of the results of the three serological assays and Ct revealed that patients whose antibody titers were judged as low in the IgG avidity and PA assays showed low Ct (i.e., high viral load), whereas non-spreaders tended to show low viral load. CONCLUSIONS: Our preliminary seroepidemiologic analysis of a population of 31 patients with measles suggests that PA and IgG avidity assays may be used for the identification of super-spreader/spreader candidates. However, further investigations are necessary to validate the robustness of these serological assays in detecting contagious measles cases.
Assuntos
Anticorpos Antivirais , Sarampo , Surtos de Doenças , Humanos , Imunoglobulina G , Japão/epidemiologia , Sarampo/diagnóstico , Sarampo/epidemiologia , Sarampo/prevenção & controle , Vírus do Sarampo/genética , Estudos SoroepidemiológicosRESUMO
In the past decade, multiple mumps outbreaks have occurred in the United States, primarily in close-contact, high-density settings such as colleges, with a high attack rate among young adults, many of whom had the recommended 2 doses of mumps-measles-rubella (MMR) vaccine. Waning humoral immunity and the circulation of divergent wild-type mumps strains have been proposed as contributing factors to mumps resurgence. Blood samples from 71 healthy 18- to 23-year-old college students living in a non-outbreak area were assayed for antibodies and memory B cells (MBCs) to mumps, measles, and rubella. Seroprevalence rates of mumps, measles, and rubella determined by IgG enzyme-linked immunosorbent assay (ELISA) were 93, 93, and 100%, respectively. The index standard ratio indicated that the concentration of IgG was significantly lower for mumps than rubella. High IgG avidity to mumps Enders strain was detected in sera of 59/71 participants who had sufficient IgG levels. The frequency of circulating mumps-specific MBCs was 5 to 10 times lower than measles and rubella, and 10% of the participants had no detectable MBCs to mumps. Geometric mean neutralizing antibody titers (GMTs) by plaque reduction neutralization to the predominant circulating wild-type mumps strain (genotype G) were 6-fold lower than the GMTs against the Jeryl Lynn vaccine strain (genotype A). The majority of the participants (80%) received their second MMR vaccine ≥10 years prior to study participation. Additional efforts are needed to fully characterize B and T cell immune responses to mumps vaccine and to develop strategies to improve the quality and durability of vaccine-induced immunity.
Assuntos
Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/imunologia , Imunidade Humoral/imunologia , Vacina contra Sarampo-Caxumba-Rubéola/administração & dosagem , Vírus da Caxumba/imunologia , Caxumba/imunologia , Adolescente , Adulto , Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Criança , Pré-Escolar , Feminino , Humanos , Imunidade Humoral/efeitos dos fármacos , Imunização , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Lactente , Masculino , Vacina contra Sarampo-Caxumba-Rubéola/farmacologia , Caxumba/prevenção & controle , Caxumba/virologia , Adulto JovemRESUMO
Serological assays are useful in investigating the development of humoral immunity against SARS-CoV-2 in the context of epidemiological studies focusing on the spread of protective immunity. The plaque reduction neutralization test (PRNT) is the gold standard method to assess the titer of protective antibodies in serum samples. However, to provide a result, the PRNT requires several days, skilled operators, and biosafety level 3 laboratories. Therefore, alternative methods are being assessed to establish a relationship between their outcomes and PRNT results. In this work, four different immunoassays (Roche Elecsys® Anti SARS-CoV-2 S, Snibe MAGLUMI® SARS-CoV-2 S-RBD IgG, Snibe MAGLUMI® 2019-nCoV IgG, and EUROIMMUN® SARS-CoV-2 NeutraLISA assays, respectively) have been performed on individuals healed after SARS-CoV-2 infection. The correlation between each assay and the reference method has been explored through linear regression modeling, as well as through the calculation of Pearson's and Spearman's coefficients. Furthermore, the ability of serological tests to discriminate samples with high titers of neutralizing antibodies (>160) has been assessed by ROC curve analyses, Cohen's Kappa coefficient, and positive predictive agreement. The EUROIMMUN® NeutraLISA assay displayed the best correlation with PRNT results (Pearson and Spearman coefficients equal to 0.660 and 0.784, respectively), as well as the ROC curve with the highest accuracy, sensitivity, and specificity (0.857, 0.889, and 0.829, respectively).
Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Neutralizantes , Anticorpos Antivirais , COVID-19/diagnóstico , Teste para COVID-19 , Humanos , Imunoglobulina G , Sensibilidade e Especificidade , Testes Sorológicos/métodosRESUMO
Convalescent plasma (CP) therapy has been used since the early 1900s to treat emerging infectious diseases; its efficacy was later associated with the evidence that polyclonal neutralizing antibodies can reduce the duration of viremia. Recent large outbreaks of viral diseases for which effective antivirals or vaccines are still lacking has renewed the interest in CP as a life-saving treatment. The ongoing COVID-19 pandemic has led to the scaling up of CP therapy to unprecedented levels. Compared with historical usage, pathogen reduction technologies have now added an extra layer of safety to the use of CP, and new manufacturing approaches are being explored. This review summarizes historical settings of application, with a focus on betacoronaviruses, and surveys current approaches for donor selection and CP collection, pooling technologies, pathogen inactivation systems, and banking of CP. We additionally list the ongoing registered clinical trials for CP throughout the world and discuss the trial results published thus far.
Assuntos
Infecções por Coronavirus/terapia , Pneumonia Viral/terapia , Anticorpos Neutralizantes/análise , Bancos de Espécimes Biológicos/normas , COVID-19 , Seleção do Doador/métodos , Seleção do Doador/normas , Ensaio de Imunoadsorção Enzimática , Humanos , Imunização Passiva/efeitos adversos , Imunização Passiva/normas , Testes de Neutralização/normas , Pandemias , Síndrome Respiratória Aguda Grave/terapia , Soroterapia para COVID-19RESUMO
Accurate diagnostics underpin effective public health responses to emerging viruses. For viruses, such as Zika virus (ZIKV), where the viremia clears quickly, antibody-based (IgM or IgG) diagnostics are recommended for patients who present 7 days after symptom onset. However, cross-reactive antibody responses can complicate test interpretation among populations where closely related viruses circulate. We examined the accuracy (proportion of samples correctly categorized as Zika positive or negative) for antibody-based diagnostics among Brazilian residents (Rio de Janeiro) during the ZIKV outbreak. Four ZIKV enzyme-linked immunosorbent assays (ELISAs; IgM and IgG Euroimmun, IgM Novagnost, and CDC MAC), two dengue ELISAs (IgM and IgG Panbio), and the ZIKV plaque reduction neutralization test (PRNT) were evaluated. Positive samples were ZIKV PCR confirmed clinical cases collected in 2015-2016 (n = 169); negative samples (n = 236) were collected before ZIKV was present in Brazil (≤2013). Among serum samples collected ≥7 days from symptom onset, PRNT exhibited the highest accuracy (93.7%), followed by the Euroimmun IgG ELISA (77.9%). All IgM assays exhibited lower accuracy (<75%). IgG was detected more consistently than IgM among ZIKV cases using Euroimmun ELISAs (68% versus 22%). Anti-dengue virus IgM ELISA was positive in 41.1% of confirmed ZIKV samples tested. The Euroimmun IgG assay, although misdiagnosing 22% of samples, provided the most accurate ELISA. Anti-ZIKV IgG was detected more reliably than IgM among ZIKV patients, suggesting a secondary antibody response to assay antigens following ZIKV infection. Antibody ELISAs need careful evaluation in their target population to optimize use and minimize misdiagnosis, prior to widespread deployment, particularly where related viruses cocirculate.
Assuntos
Infecção por Zika virus , Zika virus , Anticorpos Antivirais , Brasil , Ensaio de Imunoadsorção Enzimática , Humanos , Imunoglobulina G , Imunoglobulina M , Testes Sorológicos , Infecção por Zika virus/diagnósticoRESUMO
For the control of immunity in COVID-19 survivors and vaccinated subjects, there is an urgent need for reliable and rapid serological assays. Based on samples from 63 COVID-19 survivors up to 7 months after symptom onset, and on 50 serum samples taken before the beginning of the pandemic, we compared the performances of three commercial immunoassays for the detection of SARS-CoV-2 IgA and IgG antibodies (Euroimmun SARS-COV-2 IgA/IgG, Mikrogen recomWell SARS-CoV-2 IgA/IgG, and Serion ELISA agile SARS-CoV-2 IgA/IgG) and three rapid lateral flow (immunochromatographic) tests (Abbott PanBio COVID-19 IgG/IgM, Nadal COVID-19 IgG/IgM, and Cleartest Corona 2019-nCOV IgG/IgM) with a 50% plaque-reduction neutralization test (PRNT50) representing the gold standard. Fifty-seven out of 63 PCR-confirmed COVID-19 patients (90%) showed neutralizing antibodies. The sensitivity of the seven assays ranged from 7.0% to 98.3%, and the specificity ranged from 86.0% to 100.0%. Only one commercial immunoassay showed a sensitivity and specificity of greater than 98%.
Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , Humanos , Imunoensaio , Imunoglobulina M , Pandemias , Sensibilidade e EspecificidadeRESUMO
OBJECTIVES: SARS-CoV-2 serology presents an important role in several aspects of COVID-19 pandemic. Immunoassays performances have to be accurately evaluated and correlated with neutralizing antibodies. We investigated the analytical and clinical performances of a SARS-CoV-2 RBD IgG assay, automated on a high throughput platform, and the correlation of the antibodies (Ab) levels with the plaque reduction neutralization (PRNT50) Ab titers. METHODS: A series of 546 samples were evaluated by SARS-CoV-2 RBD IgG assay (Snibe diagnostics), including 171 negative and 168 positive SARS-CoV-2 subjects and a further group of 207 subjects of the COVID-19 family clusters follow-up cohort. RESULTS: Assay imprecision ranged from 3.98 to 12.18% being satisfactory at low and medium levels; linearity was excellent in all the measurement range. Considering specimens collected after 14 days post symptoms onset, overall sensitivity and specificity were 99.0 and 92.5%, respectively. A total of 281 leftover samples results of the PRNT50 test were available. An elevated correlation was obtained between the SARS-CoV-2 RBD IgG assay and the PRNT50 titer at univariate (ρ=0.689) and multivariate (ρ=0.712) analyses. CONCLUSIONS: SARS-CoV-2 S-RBD IgG assay shows satisfactory analytical and clinical performances, and a strong correlation with sera neutralizing activity.
Assuntos
Anticorpos Neutralizantes/imunologia , Imunoglobulina G/imunologia , Testes de Neutralização/métodos , SARS-CoV-2/metabolismo , Glicoproteína da Espícula de Coronavírus/imunologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , COVID-19/patologia , COVID-19/virologia , Criança , Feminino , Humanos , Imunoensaio/métodos , Imunoglobulina G/sangue , Masculino , Pessoa de Meia-Idade , Subunidades Proteicas/imunologia , SARS-CoV-2/isolamento & purificação , Índice de Gravidade de Doença , Adulto JovemRESUMO
There is an increasing demand for monoclonal antibody (mAb) therapies to confer passive immunity against viral diseases. Respiratory syncytial virus (RSV) is the most common cause of bronchiolitis, lower respiratory tract infections, and hospitalization in infants. Currently, there is no RSV vaccine but a humanized mAb available for high risk infants. MK-1654 is a fully human mAb with YTE mutation in the fragment crystallizable (Fc) region to extend the half-life in circulation. It binds to a highly conserved epitope of RSV Fusion protein with high affinity and neutralizes RSV infection. A functional cell-based assay is a regulatory requirement for clinical development, commercial release, and stability testing of MK-1654. In this study, we have evaluated three RSV neutralization assays to test the potency of MK-1654, including an imaging-based virus reduction neutralization test (VRNT) and two reporter virus-based assays (RSV-GFP and RSV-NLucP). All three methods showed good dose response curves of MK-1654 with similar EC50 values. RSV-NLucP method was chosen for further development because it is simple and can be easily adapted to quality control testing laboratories. After optimization, the RSV-NLucP assay was pre-qualified with good linearity, relative accuracy, intermediate precision, and specificity, therefore suitable for a cell-based potency assay.
Assuntos
Anticorpos Monoclonais , Anticorpos Antivirais , Infecções por Vírus Respiratório Sincicial , Vírus Sincicial Respiratório Humano , Anticorpos Monoclonais/farmacologia , Anticorpos Neutralizantes/farmacologia , Anticorpos Antivirais/farmacologia , Humanos , Testes de Neutralização , Infecções por Vírus Respiratório Sincicial/tratamento farmacológico , Proteínas Virais de Fusão/imunologiaRESUMO
Background & objectives: Coronavirus disease 2019 (COVID-19) caused by severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) continues to be a devastating pandemic. This study was aimed at performance assessment of SARS-CoV-2 IgM and IgG ELISAs, and investigation of their utility for patient diagnosis and sero-epidemiologic investigations. Methods: Serum/plasma samples from COVID-19 patients or asymptomatic contacts (n=180) and healthy donors (n=90) were tested in parallel using two commercial IgM ELISAs (Erbalisa and Inbios), and four IgG ELISAs (Kavach, Euroimmun, Erbalisa and Inbios) along with an indigenous ß-propiolactone inactivated virus-based ELISA (IRSHA-IgG-ELISA). Plaque reduction neutralization test (PRNT) was used as reference test. Results: Among 180 COVID-19 patients, 125 tested positive by PRNT. Inbios-IgM-ELISA showed sensitivity (Se)/specificity (Sp)/positive predictive value (PPV)/negative predictive value (NPV) of 93.6/97.8/98.4/94.4 per cent in relation to PRNT, and performed better than Erbalisa-IgM-ELISA (Se: 48%, Sp: 95.6%, PPV: 95.2%, NPV: 65.2%). During the first week of disease, only 47.4 per cent of the COVID-19 patients tested IgM positive by Inbios-IgM-ELISA, detection improving at two weeks and beyond (~86-100%). Among IgG tests, Inbios-IgG-ELISA ranked first in terms of sensitivity (83.2%), followed by IRSHA (64.8%), Euroimmun (64%), Erbalisa (57.6%) and Kavach (56%) tests. For all IgG tests, sensitivity improved during the third (73.9-95.7%) and fourth week (100%) of illness. The specificity (96.7-100%) and PPV (96.2-100%) of all IgG tests were high; NPV ranged between 71.9 and 87.1 per cent with Inbios-IgG-ELISA scoring highest. Interpretation & conclusions: Our results show that IgM detection by the current, most sensitive ELISAs cannot replace molecular diagnosis, but may aid as a supplement test. The available IgG tests are suitable for serosurveys for the assessment of previous virus exposure.
Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , Ensaio de Imunoadsorção Enzimática , Humanos , Imunoglobulina G , Imunoglobulina M , Testes de Neutralização , Sensibilidade e EspecificidadeRESUMO
Measurement of measles virus-specific IgG is used to assess presumptive evidence of immunity among immunocompetent individuals with uncertain immune or vaccination status. False-negative test results may lead to unnecessary quarantine and exclusion from activities such as employment, education, and travel or result in unnecessary revaccination. In contrast, false-positive results may fail to identify susceptible individuals and promote spread of disease by those who are exposed and unprotected. To better understand the performance characteristics of tests to detect measles IgG, we compared five widely used, commercially available measles IgG test platforms using a set of 223 well-characterized serum samples. Measles virus neutralizing antibodies were also measured by in vitro plaque reduction neutralization, the gold standard method, and compared to IgG test results. Discrepant results were observed for samples in the low-positive ranges of the most sensitive tests, but there was good agreement across platforms for IgG-negative sera and for samples with intermediate to high levels of IgG. False-negative test results occurred in approximately 11% of sera, which had low levels of neutralizing antibody.
Assuntos
Vírus do Sarampo , Sarampo , Anticorpos Antivirais , Ensaio de Imunoadsorção Enzimática , Humanos , Imunoensaio , Imunoglobulina G , Sarampo/diagnóstico , Testes de Neutralização , Sensibilidade e EspecificidadeRESUMO
BACKGROUND: The plaque reduction neutralization test (PRNT), which measures a subset of immunoglobulin antibodies (functional neutralizing antibodies), and the enzyme-linked immunosorbent assay (ELISA), which measures total immunoglobulin (neutralizing and nonneutralizing antibodies), characterize different aspects of the anti-mumps virus antibody response after vaccination. METHODS: Data from a recent phase 3 clinical trial (NCT01681992) of 2 measles-mumps-rubella vaccines were used to compare anti-mumps antibody responses measured using an unenhanced PRNT (GSK; seropositivity cutoff and threshold, 2.5 and 4 times the 50% end-point dilution, respectively) with those estimated using an ELISA (thresholds, 5 and 10 ELISA units/mL, respectively). RESULTS: Of 3990 initially seronegative samples, 3284 (82.3%) were seropositive after vaccination for anti-mumps antibodies in both assays. The Pearson correlation coefficient for double-positive samples was 0.57, indicative of a moderate correlation. Receiver operating characteristic curve analysis showed that an ELISA threshold of 51.7 ELISA units/mL best corresponded to the PRNT seroresponse threshold. There was no obvious vaccine brand effect on the correlation between assays. CONCLUSIONS: The moderate correlation between the anti-mumps antibody measurements obtained with PRNT and ELISA reflects different aspects of the serological response. In the absence of a well-defined protective serological threshold, PRNT provides complementary information on the antibody response, whereas ELISA remains a critically useful measurement of vaccine immunogenicity.
Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Ensaio de Imunoadsorção Enzimática/métodos , Vacina contra Sarampo-Caxumba-Rubéola/administração & dosagem , Vírus da Caxumba/imunologia , Testes de Neutralização/métodos , Ensaios Clínicos Fase III como Assunto , Feminino , Humanos , Lactente , Masculino , Curva ROC , Ensaio de Placa Viral/métodosRESUMO
Since its recent discovery, Bourbon virus has been isolated from a human and ticks. To assess exposure of potential vertebrate reservoirs, we assayed banked serum and plasma samples from wildlife and domestic animals in Missouri, USA, for Bourbon virus-neutralizing antibodies. We detected high seroprevalence in raccoons (50%) and white-tailed deer (86%).
Assuntos
Reservatórios de Doenças , Thogotovirus/isolamento & purificação , Animais , Animais Domésticos/virologia , Animais Selvagens/virologia , MissouriRESUMO
We tested a sample of 234 wild long-tailed macaques (Macaca fascicularis) trapped in Peninsular Malaysia in 2009, 2010, and 2016 for Zika virus RNA and antibodies. None were positive for RNA, and only 1.3% were seropositive for neutralizing antibodies. Long-tailed macaques are unlikely to be reservoirs for Zika virus in Malaysia.
Assuntos
Doenças dos Macacos/epidemiologia , Doenças dos Macacos/virologia , Infecção por Zika virus/veterinária , Zika virus , Animais , Animais Selvagens , Macaca fascicularis , Malásia/epidemiologia , RNA Viral , Sorogrupo , Zika virus/classificação , Zika virus/genéticaRESUMO
BACKGROUND: Dengue is an important mosquito-borne disease. There is currently only one licensed vaccine for dengue prevention. The vaccine provides higher efficacy in pre-vaccination dengue-seropositive persons but a higher risk of subsequent more severe dengue in dengue-seronegative persons. It is recommended that the dengue vaccine may be given in dengue-seropositive individuals or as mass vaccination without individual pre-vaccination screening in areas where the dengue seroprevalence is > 80% in children aged 9 years. We evaluated a dengue specific immunoglobulin G monoclonal antibody-based capture enzyme-linked immunosorbent assay (MAb-ELISA) in the diagnosis of previous dengue infection using serum samples from the cohort study in Ratchaburi Province, Thailand. METHODS: The MAb-ELISA was compared to 70% plaque reduction neutralization test (PRNT70) in 453 serum samples from children aged 3-11 years in Ratchaburi Province, Thailand. RESULTS: The sensitivity and specificity of MAb-ELISA at the positive to negative (P/N) ratio cut-off level of > 3 were both 0.91 in the diagnosis of previous dengue infection, compared to PRNT70. The false positivity was mainly in Japanese encephalitis (JE) seropositive subjects. CONCLUSIONS: This research provides evidence that MAb-ELISA is useful for dengue seroprevalence study and dengue pre-vaccination screening. JE seropositivity was the major cause of false positive result in the study population.
Assuntos
Vírus da Dengue/isolamento & purificação , Dengue/diagnóstico , Ensaio de Imunoadsorção Enzimática/normas , Técnicas Microbiológicas/métodos , Anticorpos Monoclonais/imunologia , Anticorpos Antivirais/sangue , Criança , Pré-Escolar , Estudos de Coortes , Dengue/sangue , Dengue/epidemiologia , Vírus da Dengue/imunologia , Humanos , Imunoglobulina M/sangue , Técnicas Microbiológicas/normas , Testes de Neutralização , Sensibilidade e Especificidade , Estudos Soroepidemiológicos , Tailândia/epidemiologiaRESUMO
BACKGROUND: Yellow fever, Dengue, West Nile and Zika viruses are re-emerging mosquito-borne Flaviviruses of public health concern. However, the extent of human exposure to these viruses and associated disease burden in Kenya and Africa at large remains unknown. We assessed the seroprevalence of Yellow fever and other Flaviviruses in human populations in West Pokot and Turkana Counties of Kenya. These areas border Uganda, South Sudan and Ethiopia where recent outbreaks of Yellow fever and Dengue have been reported, with possibility of spillover to Kenya. METHODOLOGY: Human serum samples collected through a cross-sectional survey in West Pokot and Turkana Counties were screened for neutralizing antibodies to Yellow fever, Dengue-2, West Nile and Zika virus using the Plaque Reduction Neutralization Test (PRNT). Seroprevalence was compared by county, site and important human demographic characteristics. Adjusted odds ratios (aOR) were estimated using Firth logistic regression model. RESULTS: Of 877 samples tested, 127 neutralized with at least one of the four flaviviruses (14.5, 95% CI 12.3-17.0%), with a higher proportion in Turkana (21.1%, n = 87/413) than in West Pokot (8.6%, n = 40/464). Zika virus seroprevalence was significantly higher in West Pokot (7.11%) than in Turkana County (0.24%; χ2 P < 0.0001). A significantly higher Yellow fever virus seroprevalence was also observed in Turkana (10.7%) compared to West Pokot (1.29%; χ2 P < 0.0001). A high prevalence of West Nile virus was detected in Turkana County only (10.2%) while Dengue was only detected in one sample, from West Pokot. The odds of infection with West Nile virus was significantly higher in males than in females (aOR = 2.55, 95% CI 1.22-5.34). Similarly, the risk of Zika virus infection in West Pokot was twice higher in males than females (aOR = 2.01, 95% CI 0.91-4.41). CONCLUSION: Evidence of neutralizing antibodies to West Nile and Zika viruses indicates that they have been circulating undetected in human populations in these areas. While the observed Yellow Fever prevalence in Turkana and West Pokot Counties may imply virus activity, we speculate that this could also be as a result of vaccination following the Yellow Fever outbreak in the Omo river valley, South Sudan and Uganda across the border.
Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Infecções por Flavivirus/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Animais , Criança , Estudos Transversais , Culicidae/virologia , Dengue/epidemiologia , Dengue/imunologia , Feminino , Flavivirus , Infecções por Flavivirus/imunologia , Humanos , Quênia/epidemiologia , Masculino , Pessoa de Meia-Idade , Testes de Neutralização , Fatores de Risco , Estudos Soroepidemiológicos , Febre do Nilo Ocidental/epidemiologia , Febre do Nilo Ocidental/imunologia , Adulto Jovem , Infecção por Zika virus/epidemiologia , Infecção por Zika virus/imunologiaRESUMO
BACKGROUND: We recently conducted a serosurvey of newly arrived workers in Taiwan from four Southeast Asian countries which revealed that 1% of the migrant workers had laboratory-confirmed recent Zika virus (ZIKV) infection. Taiwan, where Aedes mosquitoes are prevalent, has a close relationship with Southeast Asian countries. Up to now, 21 imported cases of ZIKV infection have been reported in Taiwan, but there has been no confirmed indigenous case. The aim of this serosurvey was to assess whether there was unrecognized ZIKV infections in Taiwan. METHODS: A total of 212 serum samples collected in a cross-sectional seroepidemiologic study conducted during the end of the 2015 dengue epidemic in Tainan, Taiwan, were analyzed. Anti-ZIKV IgM and IgG were tested using commercial enzyme-linked immunosorbent assays (ELISAs). Plaque reduction neutralization tests (PRNTs) for ZIKV and four dengue virus (DENV) serotypes were performed for samples with positive anti-ZIKV antibodies. A confirmed case of ZIKV infection was defined by ZIKV PRNT90 titer ratio ≥ 4 compared to four DENV serotypes. RESULTS: The mean age of the 212 participants was 54.0 years (standard deviation 13.7 years), and female was predominant (67.0%). Anti-ZIKV IgM and IgG were detected in 0 (0%) and 9 (4.2%) of the 212 participants, respectively. For the 9 samples with anti-ZIKV IgG, only 1 sample had 4 times higher ZIKV PRNT90 titers compared to PRNT90 titers against four dengue virus serotypes; this individual denied having traveled abroad. CONCLUSIONS: The results suggest that undetected indigenous ZIKV transmission might have occurred in Taiwan. The findings also suggest that the threat of epidemic transmission of ZIKV in Taiwan does exist due to extremely low-level of herd immunity. Our study also indicates that serological tests for ZIKV-specific IgG remain a big challenge due to cross-reactivity, even in dengue non-endemic countries.
Assuntos
Infecção por Zika virus/epidemiologia , Adulto , Idoso , Anticorpos Anti-Idiotípicos/sangue , Reações Cruzadas , Estudos Transversais , Dengue/epidemiologia , Dengue/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes de Neutralização , Estudos Soroepidemiológicos , Testes Sorológicos/métodos , Taiwan/epidemiologia , Infecção por Zika virus/imunologiaRESUMO
Background & objectives: West Nile virus (WNV) is a neurotropic flavivirus that has emerged globally as a significant cause of viral encephalitis. The early confirmatory diagnosis of WNV infections is important for timely clinical management and in areas where multiple flaviviruses are endemic. Diagnosis of WNV infection is primarily based on serodiagnosis, followed by virus isolation and identification. The aim of this study was to develop and evaluate a highly sensitive and specific immunoglobulin M (IgM) ELISA using the recombinant CprM protein (rWNV-CprM) for rapid, early and accurate diagnosis of WNV. Methods: The gene coding for the CprM protein of WNV was cloned and expressed in pET 28a vector followed by purification. An indirect IgM microplate ELISA using purified rWNV-CprM protein was optimized having no cross-reactivity with healthy human serum and serum samples obtained from patients with dengue and Japanese encephalitis viruses infection. Results: The comparative evaluation of this rWNV-CprM protein-specific IgM ELISA with plaque reduction neutralization test using 105 blood samples collected from patients suspected to have acute WNV infection revealed 98 per cent concordance with sensitivity and specificity of 100 and 97 per cent, respectively. Interpretation & conclusions: The recombinant CprM protein-based WNV-specific ELISA reported in this study may be useful for rapid screening of large numbers of blood samples in endemic areas during outbreaks.