Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Medicina (Kaunas) ; 58(5)2022 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-35630105

RESUMO

Background and Objectives: Minimally invasive spine surgery reduces destruction of the paraspinal musculature and improves spinal stability. Nevertheless, screw loosening remains a challenging issue in osteoporosis patients receiving spinal fixation and fusion surgery. Moreover, adjacent vertebral compression fracture is a major complication, particularly in patients with osteoporosis. We assessed long-term imaging results to investigate the outcomes of osteoporosis patients with two-level degenerative spine disease receiving minimally invasive surgery with the assistance of a robotic system. Materials and Methods: We retrospectively analyzed consecutive osteoporosis patients who underwent minimally invasive surgery with the assistance of a robotic system at our institution during 2013-2016. All patients were diagnosed with osteoporosis according to the World Health Organization criteria. All patients were diagnosed with two levels of spinal degenerative disease, including L34, L45, or L5S1. The study endpoints included screw-loosening condition, cage fusion, and vertebral body heights of the adjacent, first fixation segment, and second fixation segments before and after surgery, including the anterior, middle, and posterior third parts of the vertebral body. Differences in vertebral body heights before and after surgery were evaluated using the F-test. Results: Nineteen consecutive osteoporosis patients were analyzed. A lower rate of screw loosening was observed in osteoporosis patients in our study. There were no significant differences between the preoperative and postoperative vertebral body heights, including adjacent and fixation segments. Conclusions: According to our retrospective study, we report that minimally invasive surgery with the assistance of a robotic system provided better screw fixation, a lower rate of screw loosening, and a lesser extent of vertebral compression fracture after spinal fixation and fusion surgery in osteoporosis patients.


Assuntos
Fraturas por Compressão , Osteoporose , Procedimentos Cirúrgicos Robóticos , Fraturas da Coluna Vertebral , Fusão Vertebral , Fraturas por Compressão/etiologia , Fraturas por Compressão/cirurgia , Humanos , Vértebras Lombares/cirurgia , Osteoporose/etiologia , Estudos Retrospectivos , Fraturas da Coluna Vertebral/cirurgia , Fusão Vertebral/métodos
2.
J Clin Med ; 11(17)2022 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-36078918

RESUMO

Robot-assisted pedicle screw placement for spine surgery has become popular in recent years. This study compares clinical, radiographic outcomes and the screw loosening rate between robot-assisted and fluoroscopy-guided pedicle screw placement in patients who underwent transforaminal lumbar interbody fusion (TLIF). We retrospectively examined 108 patients with the degenerative lumbar disease who underwent TLIF. According to whether the robotic system was used, patients were assigned to either the robot-assisted (Ro TLIF, n = 29) or fluoroscopy-guided TLIF (FG TLIF, n = 79) group. Radiographic parameters and patient-reported outcomes, including leg and back pain visual analog scale (VAS) and Oswestry Disability Index (ODI), were assessed. Loosening signs were noted in 48 out of 552 pedicle screws. The screw loosening rate was higher in the FG TLIF (10.2%) than Ro TLIF group (4.3%). A significant correlation was found between screw loosening and age, the number of level(s) fused, and the ratio of the average distance from the pedicle screw to the upper endplate to vertebral body height. VAS-leg, VAS-back, and ODI showed significant improvements in both groups postoperatively (all p < 0.05). These results indicated that robot-assisted pedicle screw placement in TLIF had a lower screw loosening rate and similar patient-reported outcomes compared with the fluoroscopy-guided technique.

3.
Clin Interv Aging ; 17: 589-599, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35497053

RESUMO

Purpose: Severe complications, including screw loosening events and low fusion rates, in spinal fusion surgery using the traditional open method are problematic. This retrospective study aimed to evaluate the rate of screw loosening and the clinical outcomes of bone-mounted miniature robot-assisted pedicle screw placement in patients treated for degenerative spinal disease. Patients and Methods: Data were collected from the medical records of 118 patients (mean age, 69 years). Differences in clinical outcomes, including the Oswestry disability index, visual analog scale score, screw loosening rate, cage fusion rate, and complications, were evaluated among different bone mineral densities. Results: The screw loosening and cage fusion rates for all patients, normal bone mineral density, osteopenia, and osteoporosis groups were 12%, 8.6%, 13.1%, and 14%, respectively, and 85.3%, 93%, 82.5%, and 81.4%, respectively. There was a higher screw loosening rate and a lower cage fusion rate in the osteopenia and osteoporosis groups than in the normal bone density group. The accuracy of the screw placement was 97.3%. There were no statistically significant differences in the Oswestry disability index and visual analog scale scores, and no major complications for dural tear or vascular or visceral injury. Conclusion: Our study demonstrated an acceptable screw loosening rate in patients with osteoporosis compared to that in patients with normal bone mineral density. The robotic system resulted in accurate screw placement in patients with osteoporosis.


Assuntos
Doenças Ósseas Metabólicas , Osteoporose , Procedimentos Cirúrgicos Robóticos , Idoso , Doenças Ósseas Metabólicas/diagnóstico por imagem , Humanos , Osteoporose/cirurgia , Radiografia , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa