Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 327
Filtrar
1.
Clin Oral Investig ; 28(9): 478, 2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39122868

RESUMO

OBJECTIVES: This study aimed to evaluate the dentin bond performance of various resin luting cement (RLC) systems combined with universal adhesives in different luting strategies. MATERIALS AND METHODS: Three self-adhesive resin luting cements (SRLCs) were used with universal adhesives as primers. Twelve specimens per group were prepared to measure shear bond strength (SBS) under distinct luting strategies in etch-&-rinse and self-etch modes. Regarding luting strategies, the bonded specimens were categorized into four groups based on tooth primer application and the curing mode of the SRLC paste: (i) with light irradiation of the tooth primer (wL) + dual-cure mode (DC) of the SRLC paste, (ii) wL + self-cure mode (SC) of the SRLC paste, (iii) without light irradiation of the tooth primer (woL) + DC mode of the SRLC paste, and (iv) woL + SC mode of the SRLC paste. Specimens were also subjected to different storage conditions: 24 h in water (baseline condition) and 10,000 cycles of thermal cycling. RESULTS: Luting strategy, storage condition, and SRLC system type significantly influenced dentin SBS values in both etching modes. Notably, certain SRLCs exhibited significantly higher dentin SBS when the primer was light-irradiated compared with no primer irradiation. CONCLUSION: Most SRLCs demonstrated higher dentin bond strength with light-irradiated primers, suggesting potential enhancement of dentin bond performance via primer light irradiation.


Assuntos
Colagem Dentária , Análise do Estresse Dentário , Teste de Materiais , Cimentos de Resina , Resistência ao Cisalhamento , Cimentos de Resina/química , Colagem Dentária/métodos , Adesivos Dentinários/química , Propriedades de Superfície , Técnicas In Vitro , Cimentos Dentários/química , Dentina , Humanos
2.
Odontology ; 112(1): 158-168, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37173534

RESUMO

Detachment is the major cause of failure of endodontic fibre posts. Hollow posts have been recently introduced to overcome such issue. The primary aim of this pilot study was to compare the push-out bond strength of hollow posts and traditional solid posts. Eight round-shaped single-canal premolars extracted for periodontal reason were selected as sample and equally randomized into two groups: (i) traditional solid fibre posts-TECH21xop and ii) hollow fibre posts-TECHOLE. A dual-curing self-adhesive cement (new TECHCEM) was used for posts placement. Six horizontal sections-two from each portion of the root (coronal, middle and apical)-were obtained from each sample root, yielding a total of 24 sections for each group. Push-out test was performed on the sections and bond strength values were compared between groups and within each group. Scanning electron microscope (SEM) fractographical analysis was conducted on each section. Additional SEM and EDX analyses were performed on new samples of both posts, to assess fibres density and distribution, and the chemical composition of the fibres and the matrix. Hollow posts showed a significantly higher push-out bond strength (6.36 ± 1.22 MPa) than solid posts (3.64 ± 1.62 MPa). Among the three root portions of the same group, there was no significant difference in bond strength. In both groups, the most frequent type of fracture was a mixed adhesive failure with the cement covering 0 to 50% of the post perimeter. Hollow post fibres appear more similar in size and have a more homogeneous distribution, compared to solid posts. The two post types also have different chemical compositions.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Cimentos de Resina/química , Projetos Piloto , Teste de Materiais , Análise do Estresse Dentário , Dentina , Vidro
3.
J Esthet Restor Dent ; 36(5): 723-736, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38174898

RESUMO

OBJECTIVES: This randomized clinical trial evaluated and compared the 2-year clinical performance of two ion-releasing bulk-fill composites (Cention N and Surefil One) with that of a conventional bulk-fill resin composite (Powerfil) in Class I and II cavities. METHODS: Thirty-two patients, each with 3 Class I and/or Class II cavities under occlusion, were enrolled in this trial. A total of 96 restorations were placed, 32 for each material, as follows: a self-adhesive composite; Surefil-one, alkasite; Cention N, and a bulk-fill resin composite; Powerfil. The restorations were placed by a single operator. Clinical evaluation was performed at baseline (1-week), 6-months, 1-year, and 2-years by two independent examiners using the FDI criteria. Intergroup and intragroup comparisons were analyzed using the Kruskal-Wallis and Friedman Tests. Multiple comparisons between groups were analyzed using the Mann-Whitney and Wilcoxon-rank tests. The level of significance was set at α = 0.05. RESULTS: Twenty-seven patients with a total of 81 restorations were evaluated at the end of the 2-years with 84.35% recall rates. Clinical success rates were 100%, 100%, and 96.3% for Powerfil, Surefil-one, and Cention N, respectively. Cention N showed a statistically significant (p < 0.05) decreased marginal integrity in comparison with resin composite at the 2-year evaluation. No recurrent decay was detected in any restoration. CONCLUSIONS: Both ion-releasing bulk-fill composites provided acceptable clinical performance similar to bulk-fill composite in Class I and II restorations over a 2-year period. CLINICAL RELEVANCE: The results of this trial suggests that there is a promising evidence supporting the use of ion-releasing composites.


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Humanos , Restauração Dentária Permanente/métodos , Resinas Compostas
4.
J Esthet Restor Dent ; 36(9): 1311-1325, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38655672

RESUMO

OBJECTIVE: This randomized controlled clinical trial compared the clinical efficacy of self-adhesive bulk-fill Surefil One with a traditional bulk-fill composite in class II restorations. MATERIALS AND METHODS: Sixty-four direct class II composite restorations were categorized into two groups. Group I, control group (n = 32): cavities were restored by Filtek One bulk-fill composite with Scotchbond Universal (SBU) adhesive in self-etch mode, Group II, test group (n = 32): cavities were restored by Surefil One self-adhesive bulk-fill composite. The study involved a follow-up period of 1 year, during which restorations were assessed at baseline (BL), 6 months, and 12 months using Federation Dentaire Internationale (FDI) criteria. Data analysis was performed using nonparametric tests. A comparison of restoration characteristics was performed utilizing the chi-square test (X2). The significance level was set at 0.05. RESULTS: Filtek One and Surefil One bulk-fill composites revealed clinically acceptable FDI scores over 12-month recalls. Thirty-two patients (64 restorations) were available for all follow-up visits; 100% of the restorations survived. For esthetic properties, Filtek One was far better than Surefil One at all time points. However, in terms of functional and biological properties, both restorations demonstrated comparable performances. CONCLUSIONS: Filtek One bulk-fill restorations were superior in terms of surface luster, surface staining, color match, and translucency, but Surefil One restorations performed well and were similar to Filtek One restorations; however, additional advancements and research are needed to obtain better esthetics. Furthermore, longitudinal studies with extended follow-up periods are needed to assess the clinical potential of both materials. CLINICAL SIGNIFICANCE: Both Filtek One and Surefil One met the FDI criteria, with Filtek One demonstrating superior esthetic and functional qualities and similar performance regarding biological criteria. Both innovative restorative materials show potential for clinical use. Trial registered on ClinicalTrials.gov under registration number; NCT06120868:07/11/2023.


Assuntos
Resinas Compostas , Restauração Dentária Permanente , Humanos , Feminino , Masculino , Restauração Dentária Permanente/métodos , Adulto , Cimentos de Resina/química , Pessoa de Meia-Idade , Cárie Dentária/terapia , Preparo da Cavidade Dentária/métodos , Adulto Jovem
5.
Clin Oral Investig ; 27(3): 1071-1078, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36030454

RESUMO

OBJECTIVES: To evaluate the longevity of metal-ceramic single crowns cemented onto resin composite prosthetic cores using a self-adhesive resin cement in a prospective clinical descriptive study. METHODS: A total of 152 teeth were endodontically treated and received resin composite prosthetic cores and metal-ceramic crowns cemented with a self-adhesive resin cement. The patients included in the sample were recalled for clinical and radiography evaluation in an up-to-106-month period after the final cementation procedures, with an average of 62 months of follow-up. 91.5% of the sample (142 teeth) were evaluated regarding the treatment survival rate, analyzed considering the loss of crown retention (crown debonding) and tooth loss as the primary outcome. In addition, post debonding, and root fracture occurrences were also recorded as secondary outcomes to evaluate the success rate of the prosthetic treatment. The aesthetic parameters were also evaluated according to the FDI criteria. The Kaplan-Meier method and Cox regression with 95% confidence interval were applied for the statistical analysis. RESULTS: Regarding the primary outcome, the metal-ceramic crowns cemented with self-adhesive resin cement presented a high survival rate (91.5%), with 8 crown debondings and 3 tooth losses (1 due to caries and 2 due to periodontal disease) occurring after the evaluation period. For secondary outcomes, 9 root fractures and 4 post debondings occurred, generating a success rate of 72%. All crowns had a score 1 on the FDI criteria, indicating that they were clinically excellent or very good regarding the aesthetic parameters. CONCLUSION: The metal-ceramic crowns luted with a self-adhesive resin cement presented a survival rate of 91.5% after an average of 62 months of follow-up. Furthermore, the restorations remained aesthetically satisfactory over time, without changes that would indicate prosthetic retreatment. A success rate of 72% was obtained considering the secondary outcome, mainly related to intraradicular retainer failures (root fractures or post debonding). CLINICAL SIGNIFICANCE: The self-adhesive resin cement is clinically indicated for cementation of metal-ceramic crowns onto resin composite prosthetic cores.


Assuntos
Cimentos Dentários , Cimentos de Resina , Humanos , Seguimentos , Estética Dentária , Resinas Compostas , Coroas , Cimentação/métodos , Cerâmica , Teste de Materiais , Falha de Restauração Dentária
6.
Clin Oral Investig ; 27(7): 3983-3989, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37083987

RESUMO

OBJECTIVES: To investigate the clinical performance of chairside fabricated tooth-supported posterior single crowns from lithium disilicate ceramic. MATERIALS AND METHODS: Thirty-four crowns (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein) were inserted between 2006 and 2007 and again evaluated after 15 years. Survival and success rates were calculated according to Kaplan-Meier, and the quality of the crowns was evaluated by using modified United States Public Health (USPHS) criteria. RESULTS: Twenty-two crowns were available for recall; six patients were defined as dropouts. The mean observation period was 15.2 years (± 0.2). Six failures occurred (1 technical/5 biological) resulting in a survival rate of 80.1%. The success rate was 64.2%. The roughness of the crowns increased (p = 0.021) and the majority of adhesive gaps were discolored (p = 0.001) in comparison to baseline. The color, tooth, and crown integrity remained stable over the follow-up period (p ≥ 0.317). CONCLUSION: The fabrication of tooth-supported lithium disilicate crowns using a chairside approach yielded acceptable long-term survival and success rates. Due to discoloration, the long-term use of dual-cure self-adhesive resin cements might result in unpleasing esthetic results. CLINICAL RELEVANCE: The performance of posterior lithium disilicate single crowns revealed excellent to good clinical quality and an acceptable number of events after 15 years of clinical service.


Assuntos
Desenho Assistido por Computador , Planejamento de Prótese Dentária , Humanos , Estética Dentária , Porcelana Dentária , Coroas , Cerâmica , Falha de Restauração Dentária
7.
BMC Oral Health ; 23(1): 458, 2023 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-37420233

RESUMO

BACKGROUND: The aim of this study was to assess the impact of abutments with angled screw access channel on the retention of zirconia crowns. METHODS: Seven implant replicas were inserted in epoxy resin blocks. Fourteen zirconia crowns for central incisor tooth were digitally fabricated and cemented to titanium bases (Ti-bases) with resin cement. Titanium bases were categorized into 2 groups (n = 7). Control group (Group STA) included straight screw access channel abutments. Study group (Group ASC) included angled screw access channel abutments. Following aging (5 °C-55 °C, 60 s; 250,000 cycles, 100 N, 1.67 Hz), the pull-off forces (N) were recorded by using retention test (1 mm/min). Types of failure were defined as (Type 1; Adhesive failure when luting agent predominantly remained on the Ti-base surface (> 90%); Type 2; Cohesive failure when luting agent remained on both Ti-base and crown surfaces; and Type 3; Adhesive failure when luting agent predominantly remained on the crown (> 90%). Statistical analysis was conducted by using (IBM SPSS version 28). Normality was checked by using Shapiro Wilk test and Q-Q plots. Independent t-test was then used to analogize the groups. RESULTS: Mean ± standard deviation of retention force records ranged from 1731.57 (63.68) N (group STA) to 1032.29 (89.82) N (group ASC), and there was a statistically significant variation between the 2 groups (P < .05). Failure modes were Type 2 for group STA and Type 3 for group ASC. CONCLUSIONS: The retention of zirconia crowns to abutments with a straight screw access channel is significantly higher than abutments with angled screw access channel.


Assuntos
Cimentos Dentários , Titânio , Humanos , Coroas , Parafusos Ósseos , Teste de Materiais , Análise do Estresse Dentário
8.
BMC Oral Health ; 23(1): 907, 2023 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-37993834

RESUMO

PURPOSE: To evaluate the effect of zirconia priming with MDP-Salt before MDP containing primers and self-adhesive cement on the shear bond strength. MATERIALS AND METHODS: Fully sintered high translucent zirconia specimens (n = 120) were assigned into 2 groups (n = 60 each): Control (No Pretreatment) and Methacryloyloxydecyl dihydrogen phosphate salt (MDP-Salt) pretreated. Each group was divided into 3 subgroups (n = 20) according to cementation protocol: 1) MDP + Silane primer and conventional resin cement, 2) MDP+ Bisphenyl dimethacrylate (BPDM) primer and conventional resin cement, and 3) MDP containing self-adhesive resin cement. Shear bond strength (SBS) was measured after 10,000 thermocycling. Contact angle was measured for tested groups. Surface topography was assessed using a 3D confocal laser scanning microscope (CLSM). Weibull analysis was performed for SBS and one-way ANOVA for contact angle and surface topography measurements (α = 0.05). RESULTS: The use of MDP-Salt significantly improved the SBS (p < .05) for all tested subgroups. Self-adhesive cement showed an insignificant difference with MDP + Silane group for both groups (p > .05). MDP + BPDM showed a significantly lower characteristic strength compared to self-adhesive resin cement when both were pretreated with MDP-Salt. No difference between all tested groups in the surface topographic measurements while MDP-Salt showed the highest contact angle. CONCLUSION: MDP-Salt pretreatment can improve bonding performance between zirconia and MDP containing products.


Assuntos
Colagem Dentária , Cimentos de Resina , Humanos , Cimentos de Resina/química , Cimentação , Cimentos Dentários , Sais , Silanos/química , Metacrilatos , Resistência ao Cisalhamento , Teste de Materiais , Propriedades de Superfície , Análise do Estresse Dentário
9.
Medicina (Kaunas) ; 59(10)2023 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-37893515

RESUMO

Background and Objectives: Although fiber posts are widely used in the restoration of endodontically treated teeth (ETT), their ideal cementation depth into the root canal is still debated in literature. The aim of the present study was to evaluate whether the different intra-radicular insertion lengths of the fiber posts influence the fracture strength of ETT. Materials and Methods: A total of 10 permanent human lower incisors with straight roots of similar length and volume extracted for periodontal reason were sectioned 2 mm above the cement-enamel junction (CEJ) to a total length of 18 mm and endodontically treated in the same manner, then randomly divided into two groups of five each (Groups 1 and 2, n = 5). Two sound incisors, with no endodontic treatment, were used as the control group (Group 3, n = 2). After one week of storage in a humid environment, spaces for fiber post no. 1 (Reforpost, Angelus, Londrina, PR, Brazil) were prepared in the first two groups at a depth of 5 mm (Group 1) and 7 mm (Group 2), and the fiber posts were adhesively cemented using self-adhesive resin cement (Maxcem Elite, Kerr GmbH, Herzogenrath, Germany). After 7 days, the samples were vertically positioned and fixed in a self-curing transparent acrylic resin, up to 2 mm below the CEJ level, and mechanically tested in compression after another week of storage using a displacement-controlled testing machine up to each sample's fracture. The force-displacement curves were recorded for each sample, the means were calculated for each group and a statistical comparative analysis between groups was conducted. Results: Although no statistically significant differences between groups were observed, the highest mean fracture force (N) was recorded in Group 2 (1099.41 ± 481.89) in comparison to Group 1 (985.09 ± 330.28), even when compared to the sound, non-treated teeth (1045.69 ± 146.19). Conclusions: Within the limitations of this in vitro study, teeth where fiber posts were placed deeper into the root canal (7 mm) recorded slightly higher fracture forces in comparison with shorter lengths (5 mm). However, similar biomechanical performances obtained in the mechanical tests showed no statistical differences between the 7 mm and the 5 mm inserted posts.


Assuntos
Fraturas dos Dentes , Dente não Vital , Humanos , Resistência à Flexão , Resinas Compostas , Dente não Vital/terapia , Incisivo
10.
Clin Oral Investig ; 26(1): 449-461, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34129074

RESUMO

OBJECTIVES: In the context of the phase-down of amalgam, development of easily applicable, permanent restorative materials is of high clinical interest. Aim of this study was to evaluate the clinical performance of a novel, tooth-colored, self-adhesive bulk-fill restorative (SABF, 3M Oral Care) and a conventional bulk-fill composite (Filtek One, 3M Oral Care; FOBF) for restoring class II cavities. The null-hypothesis tested was that both materials perform similar regarding clinical performance. MATERIALS AND METHODS: In this randomized split-mouth study, 30 patients received one SABF and one FOBF restoration each. Scotchbond Universal (3M Oral Care) was used as adhesive for FOBF (self-etch mode), while SABF was applied directly without adhesive. Restorations were evaluated by two blinded examiners at baseline, 6 months and 12 months employing FDI criteria. Non-parametric statistical analyses and χ2-tests (α = 0.05) were applied. RESULTS: Thirty patients (60 restorations) were available for the 6- and 12-month recalls exhibiting 100% restoration survival. All restorations revealed clinically acceptable FDI scores at all time points and for all criteria. Only regarding esthetic properties, FOBF performed significantly better than SABF regarding surface lustre (A1) and color match and translucency (A3) at all time points and marginal staining (A2b) at 12 months. CONCLUSIONS: The null-hypothesis could not be rejected. Both materials performed similarly regarding clinical performance within the first year of clinical service. SABF exhibited slightly inferior, but clinically fully acceptable esthetic properties as compared to FOBF. CLINICAL RELEVANCE: Within the limitations of this study, the self-adhesive bulk-fill restorative showed promising results and may be recommended for clinical use.


Assuntos
Restauração Dentária Permanente , Cimentos de Resina , Resinas Compostas , Cimentos Dentários , Estética Dentária , Humanos , Boca
11.
J Esthet Restor Dent ; 34(4): 721-728, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34542233

RESUMO

OBJECTIVE: This in vitro study investigated the influence of resin coating on the bonding performance of self-adhesive resin cements in single-visit computer-aided design (CAD)/computer-aided manufacturing (CAM) resin restorations. MATERIALS AND METHOD: CAD/CAM resin (1.5-mm thick) was mounted on 20 noncoated and 20 resin-coated human dentin surfaces using dual-cured self-adhesive resin cements (Panavia SA Cement Plus or Panavia SA Cement Universal, Kuraray Noritake Dental) in either self-curing or dual-curing mode. These specimens were sectioned into beam-shaped sticks and subjected to microtensile bond strength tests after 24 h of water storage. The obtained data were statistically analyzed with three-way analysis of variance (ANOVA) and t tests (α = 0.05). RESULTS: The three-way ANOVA results revealed the significant influence of resin coating, resin cement, and curing mode. Resin coating and light curing led to higher bond strengths in almost all groups. Resin-coated dentin with Panavia SA Cement Plus exhibited a mean bond strength greater than 35 MPa in both self-curing and dual-curing modes. CONCLUSIONS: In single-visit CAD/CAM resin restorations, resin coating, resin cement selection, and curing mode influenced the bonding performance of self-adhesive resin cements. In addition, resin coating and light curing increased the bond strength of self-adhesive resin cements. Resin coating and light curing are encouraged for predictable bonding performance of dual-cured self-adhesive resin cements in single-visit CAD/CAM resin restorations.


Assuntos
Colagem Dentária , Cimentos de Resina , Desenho Assistido por Computador , Colagem Dentária/métodos , Cimentos Dentários , Materiais Dentários , Dentina , Adesivos Dentinários/química , Humanos , Teste de Materiais/métodos , Cimentos de Resina/química , Propriedades de Superfície , Resistência à Tração
12.
Int J Mol Sci ; 23(2)2022 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-35054931

RESUMO

The aim of the study was to evaluate the influence of thermocycling on the shear bond strength of self-adhesive, self-etching resin cements luted to human dentin and computer-aided design/computer-aided manufacturing (CAD/CAM) ceramics. Three modern self-adhesive dental cements (Maxcem Elite, RelyX U200, Panavia SA) were used to lute three CAD/CAM ceramics (IPS Empress CAD, IPS e.max CAD, IPS e.max ZirCAD) onto the dentin. One conventional cement (Panavia V5) served as a control. After preparation, the samples were subjected to thermocycling as a method of artificial aging of dental materials applied to simulate long-term use in oral conditions. Shear bond strength was evaluated according to PN-EN ISO 29022:2013-10 and failure modes were observed under a light microscope. Statistical analysis was performed. The study demonstrated that a combination of ceramics and cements directly impacts the bond strength. The highest bond strength was observed in Panavia V5, lower in Panavia SA and Maxcem Elite and the lowest-in RelyX U200. Adhesive failure between human dentin and cements was the most common failure mode. Moreover, thermocycling highly decreased bond strength of self-adhesive, self-etching cements.


Assuntos
Cerâmica , Desenho Assistido por Computador , Adesivos Dentinários/química , Dentina/química , Cimentos de Resina/química , Temperatura , Cerâmica/química , Fenômenos Químicos , Colagem Dentária , Humanos , Teste de Materiais , Resistência ao Cisalhamento , Propriedades de Superfície
13.
Gen Dent ; 70(1): 30-33, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34978987

RESUMO

The purpose of this in vitro study was to compare the 3- and 90-day bond strengths of 3 cements used for luting metal-ceramic crowns. Zinc phosphate cement (ZPC; SS White), resin-modified glass ionomer cement (RMGIC; Fuji Plus), and self-adhesive resin cement (SARC; RelyX U200) were assessed in 2 different treatment conditions (with and without microsandblasting of the alloy) and at 2 experimental times (3 days [E1] and 90 days [E2] after cementation). The buccal surfaces of 84 bovine teeth were ground until the dentin was exposed, and 84 nickel-chromium alloy plates cast from a resin model were cemented to the dentin surfaces with 1 of the 3 cements (n = 28). In half of the specimens of each group (n = 14), the bonding surfaces of the nickel-chromium plates received 6 seconds of microsandblasting with 45-µm aluminum oxide particles prior to cementation. The compressive shear bond strengths of the specimens were evaluated in a universal testing machine at E1 and E2 (n = 7). The SARC group showed the greatest bond strength, followed by the RMGIC group, while the bond strength of the ZPC group was significantly lower (P < 0.01). For the RMGIC specimens subjected to microsandblasting, there was a statistically significant difference between the mean bond strengths at E1 and E2 (P = 0.040). All of the other cement and treatment groups showed statistically similar adhesion results at E1 and E2 (P > 0.05). The complementary test by Sidák revealed that the cements Fuji Plus and RelyX U200 showed higher values at E2 and were statistically similar to each other (P > 0.05). Although RMGIC specimens showed a lower initial bond strength than SARC specimens, the fact that the microsandblasted RMGIC subgroup was the only one that demonstrated a significant increase in bond strength with aging suggests that RMGIC can be a material of first choice because it also costs less than SARC.


Assuntos
Colagem Dentária , Animais , Bovinos , Ligas de Cromo , Cimentos Dentários/uso terapêutico , Análise do Estresse Dentário , Cimentos de Ionômeros de Vidro , Humanos , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície
14.
Lasers Med Sci ; 36(1): 219-226, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32869119

RESUMO

This study aims to evaluate the effect of Nd:YAG and femtosecond lasers irradiation on the shear bond strength (SBS) of a self-adhesive resin cement to the human dentin surface. One hundred extracted third molar teeth were randomly divided into 10 experimental groups according to dentin surface treatments; with and without the bonding agent, Nd:YAG 302 J/cm2 and 440 J/cm2, femtosecond 4 J/cm2 and 7 J/cm2, and control groups were prepared. After surface treatments, a self-adhesive resin cement was luted by using a bonding jig (Ultradent Products Inc.). The specimens were then subjected to shear test at a crosshead speed of 0.5 mm/min, and failure loads were recorded as megapascal (MPa). Two-way analysis of variance and Tukey HSD tests were performed (p Ë‚ 0.05). Representative specimens from each experimental subgroup were examined by means of SEM. The highest SBS values were obtained in Group 302 J/cm2 Nd:YAG with bonding agent, and there is no statistical difference between Group 440 J/cm2 Nd:YAG with bonding and Group 7 J/cm2 femtosecond with bonding (p > 0.05). The lowest SBS values were observed in Group control without bonding agent. Nd:YAG and femtosecond laser treatments improved the adhesion between the dentin surface and the self-adhesive resin cement.


Assuntos
Dentina/efeitos dos fármacos , Dentina/efeitos da radiação , Lasers de Estado Sólido , Cimentos de Resina/farmacologia , Análise de Variância , Colagem Dentária , Dentina/ultraestrutura , Humanos , Resistência ao Cisalhamento , Estresse Mecânico
15.
Clin Oral Investig ; 25(3): 1011-1018, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32556662

RESUMO

OBJECTIVES: To test the polymerization stress of nine self-adhesive resin composite cements (G-CEM, iCEM, Bifix SE, Maxcem Elite, PANAVIA SA, SoloCem, SmartCem 2, SpeedCEM, RelyX Unicem 2) and one glass ionomer cement (control group; Ketac Cem). MATERIALS AND METHODS: The crack propagation of a feldspar ceramic (n = 130) was determined by measuring crack lengths that originated from Vickers indentations, prior to and after the application and polymerization of the self-adhesive resin cements. Results for crack propagation were converted to polymerization stress values, and statistical analysis was performed using one-way ANOVA followed by Scheffé post hoc test. RESULTS: SmartCem 2 presented higher stress values than iCEM, SoloCem, and Ketac Cem, while Ketac Cem showed lower values than Bifix SE, Maxcem Elite, SmartCem 2, SpeedCEM, and RelyX Unicem 2. CONCLUSIONS: Self-adhesive resin composite cements differ in their polymerization stress, which may affect the durability of the restoration. For restorations made from ceramics with lower flexural strength, such as feldspar ceramics, resin composite cement materials with less polymerization stress should be preferred. CLINICAL RELEVANCE: As a high polymerization shrinkage may increase crack propagation, the determination of the polymerization stress of self-adhesive resin composite cements employed for fixing all-ceramic restorations is an important factor.


Assuntos
Colagem Dentária , Cimentos de Resina , Resinas Compostas , Cimentos Dentários , Análise do Estresse Dentário , Cimentos de Ionômeros de Vidro , Teste de Materiais , Polimerização
16.
J Contemp Dent Pract ; 22(9): 998-1002, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35000942

RESUMO

AIM: This study aimed to investigate the fibroblast cells proliferation in periradicular tissue using mineral trioxide aggregate (MTA) and self-adhesive resin cement as the adhesive material for vertical root fracture fragments following intentional replantation. MATERIALS AND METHODS: This study used 27 male New Zealand rabbits aged 8-12 weeks. The mandibular incisor of each rabbit was extracted, and to simulate vertical fracture, the incisor tooth was sectioned vertically from the cervical to the 2/3 apical. The samples were randomly divided into three groups of nine each. Group 1 (control group), no application of any material. Group 2, the fracture line was sealed using MTA. Group 3, with self-adhesive resin cement. All teeth in all groups were then inserted back (replanted) into the socket of the rabbits. Each group was further divided into three subgroups according to the duration of replantation, namely, group A: week 1, group B: week 2, and group C: week 3. Rabbits were sacrificed according to each duration of replantation for histological preparations. The number of fibroblast cells was evaluated by counting at the three viewpoints under the light-microscope (400× magnification) and Optilab camera; finally, the calculation results were averaged. Data were analyzed using a two-way ANOVA and post hoc LSD test, with a significance level of 95%. RESULTS: Following MTA application in the third week produced the highest number of fibroblast cells (104 + 29.5) compared to other groups. Conversely, the lowest number of fibroblast cells occurred in the control group in the first week of observation (4.33 + 3.5). CONCLUSION: MTA produced the greatest fibroblast cell proliferation than self-adhesive resin cement, particularly in week 3 of vertical root fractures replantation. CLINICAL SIGNIFICANCE: As the adhesive material for vertical root fracture fragments, MTA generated greater fibroblast proliferation than self-adhesive resin cement. Therefore, it is recommended to use MTA to attach vertical root fracture fragments.


Assuntos
Materiais Restauradores do Canal Radicular , Fraturas dos Dentes , Animais , Masculino , Coelhos , Compostos de Alumínio/farmacologia , Compostos de Cálcio , Proliferação de Células , Combinação de Medicamentos , Fibroblastos , Óxidos , Silicatos/farmacologia , Reimplante Dentário , Raiz Dentária/cirurgia
17.
Macromol Rapid Commun ; 41(2): e1900450, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31778252

RESUMO

The latest generation of wearable devices features materials that are flexible, conductive, and stretchable, thus meeting the requirements of stability and reliability. However, the metal conductors that are currently used in various equipments cannot achieve these high performance expectations. Hence, a mussel-inspired conductive hydrogel (HAC-B-PAM) is prepared with a facile approach by employing polyacrylamide (PAM), dopamine-functionalized hyaluronic acid (HAC), borax as a dynamic cross-linker agent, and Li+ and Na+ as conductive ions. HAC-B-PAM hydrogels demonstrate an excellent stretchability (up to 2800%), high tensile toughness (42.4 kPa), self-adhesive properties (adhesion strength to porcine skin of 49.6 kPa), and good self-healing properties without any stimuli at room temperature. Furthermore, the fabricated hydrogel-based strain sensor is sensitive to deformation and can detect human body motion. Multifunctional hydrogels can be assembled into flexible wearable devices with potential applications in the field of electronic skin and soft robotics.


Assuntos
Adesivos/química , Bivalves/química , Hidrogéis/química , Dispositivos Eletrônicos Vestíveis , Resinas Acrílicas/química , Animais , Técnicas Biossensoriais , Boratos/química , Dopamina/química , Elasticidade , Condutividade Elétrica , Humanos , Ácido Hialurônico/química , Íons/química , Movimento (Física) , Resistência ao Cisalhamento
18.
Macromol Rapid Commun ; 41(23): e2000439, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33174274

RESUMO

Nature has often been the main source of inspiration for designing smart functional materials. As an example, mussels can attach to almost any wet surfaces, for example, wood, rocks, metal, etc., due to the presence of catechols containing amino acid 3,4-dihydroxyphenyl-l-alanine (DOPA). Fabrication of mussel-inspired hydrogels using dynamic catecholato-metal coordination bonds has recently been in the limelight because of the hydrogels' ease of gelation, interesting self-healing, self-recovery, adhesiveness, and pH-responsiveness, as well as shear-thinning and mechanical properties. Mussel inspired hydrogels take advantage of catechols, for example, DOPA in the blue mussel, to undergo catecholatometal gelation through coordination chemistry. This review explores the latest developments in the fabrication of such hydrogels using catecholato-metal coordination bonds, and discusses their potential applications in sensors, flexible electronics, tissue engineering, and wound dressing. Moreover, current challenges and prospects of such hydrogels are discussed. The main focus of this paper is on providing a deeper understanding of this growing field in terms of chemistry, physics, and associated properties.


Assuntos
Bivalves , Hidrogéis , Animais , Bandagens , Catecóis , Eletrônica , Metais
19.
Int Endod J ; 53(3): 392-402, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31587321

RESUMO

AIM: To assess the extent of gaps between root dentine and titanium or fibreglass post restorations following cementation with a self-adhesive resin cement. METHODOLOGY: Fourteen root filled maxillary central incisors restored with prefabricated posts made of Fibreglass (n = 7) or Titanium (n = 7) and cemented with RelyX Unicem 2 were imaged by rapid, high-resolution phase contrast-enhanced micro-CT (PCE-CT) in a synchrotron X-ray imaging facility (ID19, ESRF, 34 KeV, 0.65 µm pixel resolution). Reconstructions were used to measure canal, cement and post perimeters and cross-sectional areas and interfacial gaps at 0.1 mm increments in the root canal space, along the cervical region of the tooth. Remnants of endodontic sealer (AH Plus), when present, were also quantified. Mann-Whitney and 2-way ANOVA tests were used to compare findings within slices and between the two post groups. Pearson correlation coefficients (r) were determined between the interfacial gaps and the other measured parameters. RESULTS: Clearly detectable gaps were found in 45% (±14%) of the interfaces between dentine and cement, along the canal in the cervical area of the tooth beneath the core. The length of interfacial gaps was moderately correlated to the canal cross-sectional area, to the canal perimeter and to the canal area filled by cement (R = 0.52 ~ 0.55, P < 0.001). There was no significant difference between samples with fibreglass or titanium (P > 0.01). Both post types had defect-free interfaces with cement. Endodontic sealer remnants were found on ~10% of the canal walls and were moderately correlated to the presence of gaps. Approximately 30% of the sealer-affected interfaces exhibited no detachment between dentine, sealer and cement. CONCLUSIONS: Self-adhesive cements had interfacial gaps along substantial regions of the root canal surface, which was not correlated with the amount of cement in the canal. PCE-CT proved to be an excellent non-destructive method to study root canal restorations of hydrated samples in 3D.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Cimentos Dentários , Cavidade Pulpar , Dentina , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície , Microtomografia por Raio-X
20.
J Esthet Restor Dent ; 32(7): 707-714, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32785989

RESUMO

AIM: To evaluate the effects of energy drinks and soft beverages on the surface degradation of different self-adhesive materials. MATERIALS AND METHODS: A 156 disc shaped specimens of each of the following materials were prepared: Alkasite (Cention N, CN), High viscozity glass ionomer (Equia Forte, EF), Glass Carbomer (GCP Fill, GC) (n = 52). After specimen preparations, baseline surface roughness measurements were done using a 3D non-contact optical profilometer. Then, specimens were subdivided into 4 subgroups (n = 13) and stored in petri dish containing Red Bull; Burn; Coca-Cola and Distilled water. The surface roughness of the specimens were measured after 1-day, 1-week, and 1-month of immersion in beverages. RESULT: It was observed that 1-month Red Bull immersion revealed the highest roughness difference (ΔRa) for each self-adhesive restorative material and this was followed by Burn. Whereas, the lowest ΔRa values were observed after 1-day coke and distilled water immersion in all tested material groups (P < 0.05). Coke and distilled water presented the energy drinks' 1-day immersion affect, after 1-week immersion (P < 0.05). CONCLUSION: The energy drinks have a substantially damaging effect on roughness of self adhesive materials compared with soft drinks and distilled water; and this effect is increasing with exposure duration.


Assuntos
Resinas Compostas , Bebidas Energéticas , Cimentos Dentários , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa