Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.954
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
CA Cancer J Clin ; 72(1): 34-56, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34792808

RESUMO

Radiation therapy (RT) continues to play an important role in the treatment of cancer. Adaptive RT (ART) is a novel method through which RT treatments are evolving. With the ART approach, computed tomography or magnetic resonance (MR) images are obtained as part of the treatment delivery process. This enables the adaptation of the irradiated volume to account for changes in organ and/or tumor position, movement, size, or shape that may occur over the course of treatment. The advantages and challenges of ART maybe somewhat abstract to oncologists and clinicians outside of the specialty of radiation oncology. ART is positioned to affect many different types of cancer. There is a wide spectrum of hypothesized benefits, from small toxicity improvements to meaningful gains in overall survival. The use and application of this novel technology should be understood by the oncologic community at large, such that it can be appropriately contextualized within the landscape of cancer therapies. Likewise, the need to test these advances is pressing. MR-guided ART (MRgART) is an emerging, extended modality of ART that expands upon and further advances the capabilities of ART. MRgART presents unique opportunities to iteratively improve adaptive image guidance. However, although the MRgART adaptive process advances ART to previously unattained levels, it can be more expensive, time-consuming, and complex. In this review, the authors present an overview for clinicians describing the process of ART and specifically MRgART.


Assuntos
Imagem por Ressonância Magnética Intervencionista/métodos , Neoplasias/radioterapia , Aceleradores de Partículas , Radioterapia (Especialidade)/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , História do Século XX , História do Século XXI , Humanos , Imagem por Ressonância Magnética Intervencionista/história , Imagem por Ressonância Magnética Intervencionista/instrumentação , Imagem por Ressonância Magnética Intervencionista/tendências , Neoplasias/diagnóstico por imagem , Radioterapia (Especialidade)/história , Radioterapia (Especialidade)/instrumentação , Radioterapia (Especialidade)/tendências , Planejamento da Radioterapia Assistida por Computador/história , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/tendências
2.
Radiology ; 311(3): e231383, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38860899

RESUMO

Background Biparametric MRI (bpMRI) of the prostate is an alternative to multiparametric MRI (mpMRI), with lower cost and increased accessibility. Studies investigating the positive predictive value (PPV) of bpMRI-directed compared with mpMRI-directed targeted biopsy are lacking in the literature. Purpose To compare the PPVs of bpMRI-directed and mpMRI-directed targeted prostate biopsies. Materials and Methods This retrospective cross-sectional study evaluated men who underwent bpMRI-directed or mpMRI-directed transrectal US (TRUS)-guided targeted prostate biopsy at a single institution from January 2015 to December 2022. The PPVs for any prostate cancer (PCa) and clinically significant PCa (International Society of Urological Pathology grade ≥2) were calculated for bpMRI and mpMRI using mixed-effects logistic regression modeling. Results A total of 1538 patients (mean age, 67 years ± 8 [SD]) with 1860 lesions underwent bpMRI-directed (55%, 849 of 1538) or mpMRI-directed (45%, 689 of 1538) prostate biopsy. When adjusted for the number of lesions and Prostate Imaging Reporting and Data System (PI-RADS) score, there was no difference in PPVs for any PCa or clinically significant PCa (P = .61 and .97, respectively) with bpMRI-directed (55% [95% CI: 51, 59] and 34% [95% CI: 30, 38], respectively) or mpMRI-directed (56% [95% CI: 52, 61] and 34% [95% CI: 30, 39], respectively) TRUS-guided targeted biopsy. PPVs for any PCa and clinically significant PCa stratified according to clinical indication were as follows: biopsy-naive men, 64% (95% CI: 59, 69) and 43% (95% CI: 39, 48) for bpMRI, 67% (95% CI: 59, 75) and 51% (95% CI: 43, 59) for mpMRI (P = .65 and .26, respectively); and active surveillance, 59% (95% CI: 49, 69) and 30% (95% CI: 22, 39) for bpMRI, 73% (95% CI: 65, 89) and 38% (95% CI: 31, 47) for mpMRI (P = .04 and .23, respectively). Conclusion There was no evidence of a difference in PPV for clinically significant PCa between bpMRI- and mpMRI-directed TRUS-guided targeted biopsy. © RSNA, 2024 Supplemental material is available for this article.


Assuntos
Biópsia Guiada por Imagem , Imageamento por Ressonância Magnética Multiparamétrica , Valor Preditivo dos Testes , Próstata , Neoplasias da Próstata , Ultrassonografia de Intervenção , Humanos , Masculino , Idoso , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Estudos Transversais , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética Multiparamétrica/métodos , Próstata/diagnóstico por imagem , Próstata/patologia , Ultrassonografia de Intervenção/métodos , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Imagem por Ressonância Magnética Intervencionista/métodos
3.
Magn Reson Med ; 92(1): 346-360, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38394163

RESUMO

PURPOSE: To introduce alternating current-controlled, conductive ink-printed marker that could be implemented with both custom and commercial interventional devices for device tracking under MRI using gradient echo, balanced SSFP, and turbo spin-echo sequences. METHODS: Tracking markers were designed as solenoid coils and printed on heat shrink tubes using conductive ink. These markers were then placed on three MR-compatible test samples that are typically challenging to visualize during MRI scans. MRI visibility of markers was tested by applying alternating and direct current to the markers, and the effects of applied current parameters (amplitude, frequency) on marker artifacts were tested for three sequences (gradient echo, turbo spin echo, and balanced SSFP) in a gel phantom, using 0.55T and 1.5T MRI scanners. Furthermore, an MR-compatible current supply circuit was designed, and the performance of the current-controlled markers was tested in one postmortem animal experiment using the current supply circuit. RESULTS: Direction and parameters of the applied current were determined to provide the highest conspicuity for all three sequences. Marker artifact size was controlled by adjusting the current amplitude, successfully. Visibility of a custom-designed, 20-gauge nitinol needle was increased in both in vitro and postmortem animal experiments using the current supply circuit. CONCLUSION: Current-controlled conductive ink-printed markers can be placed on custom or commercial MR-compatible interventional tools and can provide an easy and effective solution to device tracking under MRI for three sequences by adjusting the applied current parameters with respect to pulse sequence parameters using the current supply circuit.


Assuntos
Desenho de Equipamento , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Animais , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Artefatos , Imagem por Ressonância Magnética Intervencionista/instrumentação
4.
BJU Int ; 133(6): 709-716, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38294145

RESUMO

OBJECTIVE: To report the learning curve of multiple operators for fusion magnetic resonance imaging (MRI) targeted biopsy and to determine the number of cases needed to achieve proficiency. MATERIALS AND METHODS: All adult males who underwent fusion MRI targeted biopsy between February 2012 and July 2021 for clinically suspected prostate cancer (PCa) in a single centre were included. Fusion transrectal MRI targeted biopsy was performed under local anaesthesia using the Koelis platform. Learning curves for segmentation of transrectal ultrasonography (TRUS) images and the overall MRI targeted biopsy procedure were estimated with locally weighted scatterplot smoothing by computing each operator's timestamps for consecutive procedures. Non-risk-adjusted cumulative sum (CUSUM) methods were used to create learning curves for clinically significant (i.e., International Society of Urological Pathology grade ≥ 2) PCa detection. RESULTS: Overall, 1721 patients underwent MRI targeted biopsy in our centre during the study period. The median (interquartile range) times for TRUS segmentation and for the MRI targeted biopsy procedure were 4.5 (3.5, 6.0) min and 13.2 (10.6, 16.9) min, respectively. Among the 14 operators with experience of more than 50 cases, a plateau was reached after 40 cases for TRUS segmentation time and 50 cases for overall MRI targeted biopsy procedure time. CUSUM analysis showed that the learning curve for clinically significant PCa detection required 25 to 45 procedures to achieve clinical proficiency. Pain scores ranged between 0 and 1 for 84% of patients, and a plateau phase was reached after 20 to 100 cases. CONCLUSIONS: A minimum of 50 cases of MRI targeted biopsy are necessary to achieve clinical and technical proficiency and to reach reproducibility in terms of timing, clinically significant PCa detection, and pain.


Assuntos
Biópsia Guiada por Imagem , Curva de Aprendizado , Próstata , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Biópsia Guiada por Imagem/métodos , Idoso , Pessoa de Meia-Idade , Próstata/patologia , Próstata/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Imagem por Ressonância Magnética Intervencionista , Competência Clínica , Estudos Retrospectivos
5.
J Comput Assist Tomogr ; 48(3): 378-381, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38213070

RESUMO

ABSTRACT: We describe early ex vivo proof-of-concept testing of a novel system composed of a disposable endorectal coil and converging multichannel needle guide with a reusable clamp stand, embedded electronics, and baseplate to allow for endorectal magnetic resonance (MR) imaging and in-bore MRI-targeted biopsy of the prostate as a single integrated procedure. Using prostate phantoms imaged with standard T 2 -weighted sequences in a Siemens 3T Prisma MR scanner, we measured the signal-to-noise ratio in successive 1-cm distances from the novel coil and from a commercially available inflatable balloon coil and measured the lateral and longitudinal deviation of the tip of a deployed MR compatible needle from the intended target point. Signal-to-noise ratio obtained with the novel system was significantly better than the inflatable balloon coil at each of five 1-cm intervals, with a mean improvement of 78% ( P < 0.05). In a representative sampling of 15 guidance channels, the mean lateral deviation for MR imaging-guided needle positioning was 1.7 mm and the mean longitudinal deviation was 2.0 mm. Our ex vivo results suggest that our novel system provides significantly improved signal-to-noise ratio when compared with an inflatable balloon coil and is capable of accurate MRI-guided needle deployment.


Assuntos
Desenho de Equipamento , Biópsia Guiada por Imagem , Imagens de Fantasmas , Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Biópsia Guiada por Imagem/métodos , Biópsia Guiada por Imagem/instrumentação , Imagem por Ressonância Magnética Intervencionista/métodos , Imagem por Ressonância Magnética Intervencionista/instrumentação , Razão Sinal-Ruído , Imageamento por Ressonância Magnética/métodos , Reto/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia
6.
Radiol Med ; 129(5): 767-775, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38512628

RESUMO

PURPOSE: Breast magnetic resonance imaging (MRI) can detect some malignant lesions that are not visible on mammography (MX) or ultrasound (US). If a targeted, second-look fails, MRI-guided breast biopsy is the only available tool to obtain a tissue sample and pathological proof of these "MRI-only lesions". The aim of this study is to report the performance and underestimation rate of 9G MRI-guided vacuum-assisted breast biopsy (VABB) over 12 years at a single center. MATERIAL AND METHODS: All 9G MRI-VABB procedures performed from January 2010 to December 2021 were retrospectively reviewed. Two MRI scanners (1.5 T and 3 T) were used with the same image resolution and contrast media. All suspicious lesions detected only by breast MRI underwent biopsy. Reference standard was histological diagnosis or at least 1-year negative follow-up. All malignant and atypical lesions underwent surgery, which was used as the reference standard. RESULTS: A total of 293 biopsies were retrospectively reviewed. Histopathological VABB results revealed 142/293 (48.4%) benign lesions, 77/293 (26.2%) high-risk lesions, and 74/293 (25.2%) malignant lesions. No significant complications were observed. Surgical pathology results allowed for the reclassification of n = 7/48 B3b lesions: n = 4 were ductal carcinoma in situ, while n = 3 presented invasive features at surgical histology (2 IDC; 1 ILC). B3b underestimation occurred overall in 14.6% of B3 cases. Breast follow-up was achieved for all benign VABB results, and only one false-negative case was observed. CONCLUSION: Our results confirm that 1.5 T and 3 T MRI-guided VABB is an accurate and safe procedure for histopathologic final diagnosis of MRI-only lesions. Critical issues remain the potential high-risk underestimation rate of B3b VABB results and management of follow-up of benign lesions.


Assuntos
Neoplasias da Mama , Biópsia Guiada por Imagem , Humanos , Feminino , Estudos Retrospectivos , Neoplasias da Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Pessoa de Meia-Idade , Biópsia Guiada por Imagem/métodos , Adulto , Vácuo , Idoso , Mama/diagnóstico por imagem , Mama/patologia , Imageamento por Ressonância Magnética/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Idoso de 80 Anos ou mais
7.
Magn Reson Med ; 89(5): 2005-2013, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36585913

RESUMO

PURPOSE: To evaluate a silent MR active catheter tracking sequence that allows conducting catheter interventions with low acoustic noise levels. METHODS: To reduce the acoustic noise associated with MR catheter tracking, we implemented a technique previously used in conventional MRI. The gradient waveforms are modified to reduce the sound pressure level (SPL) and avoid acoustic resonances of the MRI system. The efficacy of the noise reduction was assessed by software-predicted SPL and verified by measurements. Furthermore, the quality of the catheter tracking signal was assessed in a phantom experiment and during interventional cardiovascular MRI sessions targeted at isthmus-related flutter ablation. RESULTS: The maximum measured SPL in the scanner room was 104 dB(A) for real-time imaging, and 88 dB(A) and 69 dB(A) for conventional and silent tracking, respectively. The SPL measured at different positions in the MR suite using silent tracking were 65-69 dB(A), and thus within the range of a normal conversation. Equivalent signal quality and tracking accuracy were obtained using the silent variant of the catheter tracking sequence. CONCLUSION: Our results indicate that silent MR catheter tracking capabilities are identical to conventional catheter tracking. The achieved acoustic noise reduction comes at no penalty in terms of tracking quality or temporal resolution, improves comfort and safety, and can overcome the need for MR-compatible communication equipment and background noise suppression during the actual interventional procedure.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Catéteres , Software , Imagem por Ressonância Magnética Intervencionista/métodos , Imagens de Fantasmas
8.
Magn Reson Med ; 89(2): 845-858, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36198118

RESUMO

PURPOSE: We describe a clinical grade, "active", monopole antenna-based metallic guidewire that has a continuous shaft-to-tip image profile, a pre-shaped tip-curve, standard 0.89 mm (0.035″) outer diameter, and a detachable connector for catheter exchange during cardiovascular catheterization at 0.55T. METHODS: Electromagnetic simulations were performed to characterize the magnetic field around the antenna whip for continuous tip visibility. The active guidewire was manufactured using medical grade materials in an ISO Class 7 cleanroom. RF-induced heating of the active guidewire prototype was tested in one gel phantom per ASTM 2182-19a, alone and in tandem with clinical metal-braided catheters. Real-time MRI visibility was tested in one gel phantom and in-vivo in two swine. Mechanical performance was compared with commercial equivalents. RESULTS: The active guidewire provided continuous "profile" shaft and tip visibility in-vitro and in-vivo, analogous to guidewire shaft-and-tip profiles under X-ray. The MRI signal signature matched simulation results. Maximum unscaled RF-induced temperature rise was 5.2°C and 6.5°C (3.47 W/kg local background specific absorption rate), alone and in tandem with a steel-braided catheter, respectively. Mechanical characteristics matched commercial comparator guidewires. CONCLUSION: The active guidewire was clearly visible via real-time MRI at 0.55T and exhibits a favorable geometric sensitivity profile depicting the guidewire continuously from shaft-to-tip including a unique curved-tip signature. RF-induced heating is clinically acceptable. This design allows safe device navigation through luminal structures and heart chambers. The detachable connector allows delivery and exchange of cardiovascular catheters while maintaining guidewire position. This enhanced guidewire design affords the expected performance of X-ray guidewires during human MRI catheterization.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Suínos , Humanos , Animais , Cateterismo Cardíaco/métodos , Desenho de Equipamento , Cateteres Cardíacos , Imagens de Fantasmas
9.
World J Urol ; 41(12): 3867-3876, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37823940

RESUMO

PURPOSE: Transperineal mpMRI-targeted fusion prostate biopsies (TPFBx) are recommended for prostate cancer diagnosis, but little is known about their learning curve (LC), especially when performed under local anaesthesia (LA). We investigated how operators' and institutions' experience might affect biopsy results. METHODS: Baseline, procedure and pathology data of consecutive TPFBx under LA were prospectively collected at two academic Institutions, from Sep 2016 to May 2019. Main inclusion criterion was a positive MRI. Endpoints were biopsy duration, clinically significant prostate cancer detection rate on targeted cores (csCDR-T), complications, pain and urinary function. Data were analysed per-centre and per-operator (with ≥ 50 procedures), comparing groups of consecutive patient, and subsequently through regression and CUSUM analyses. Learning curves were plotted using an adjusted lowess smoothing function. RESULTS: We included 1014 patients, with 27.3% csCDR-T and a median duration was 15 min (IQR 12-18). A LC for biopsy duration was detected, with the steeper phase ending after around 50 procedures, in most operators. No reproducible evidence in favour of an impact of experience on csPCa detection was found at operator's level, whilst a possible gentle LC of limited clinical relevance emerged at Institutional level; complications, pain and IPSS variations were not related to operator experience. CONCLUSION: The implementation of TPFBx under LA was feasible, safe and efficient since early phases with a relatively short learning curve for procedure time.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Masculino , Humanos , Próstata/patologia , Curva de Aprendizado , Anestesia Local , Estudos Prospectivos , Imagem por Ressonância Magnética Intervencionista/métodos , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Dor
10.
J Cardiovasc Magn Reson ; 25(1): 48, 2023 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-37574552

RESUMO

Transcatheter cardiovascular interventions increasingly rely on advanced imaging. X-ray fluoroscopy provides excellent visualization of catheters and devices, but poor visualization of anatomy. In contrast, magnetic resonance imaging (MRI) provides excellent visualization of anatomy and can generate real-time imaging with frame rates similar to X-ray fluoroscopy. Realization of MRI as a primary imaging modality for cardiovascular interventions has been slow, largely because existing guidewires, catheters and other devices create imaging artifacts and can heat dangerously. Nonetheless, numerous clinical centers have started interventional cardiovascular magnetic resonance (iCMR) programs for invasive hemodynamic studies or electrophysiology procedures to leverage the clear advantages of MRI tissue characterization, to quantify cardiac chamber function and flow, and to avoid ionizing radiation exposure. Clinical implementation of more complex cardiovascular interventions has been challenging because catheters and other tools require re-engineering for safety and conspicuity in the iCMR environment. However, recent innovations in scanner and interventional device technology, in particular availability of high performance low-field MRI scanners could be the inflection point, enabling a new generation of iCMR procedures. In this review we review these technical considerations, summarize contemporary clinical iCMR experience, and consider potential future applications.


Assuntos
Cateterismo Cardíaco , Imagem por Ressonância Magnética Intervencionista , Humanos , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
11.
Int J Hyperthermia ; 40(1): 2174274, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36775655

RESUMO

OBJECTIVES: The aim of this review was to analyze and summarize the most common adverse events (AEs) and complications after magnetic resonance-guided focused ultrasound (MRgFUS) therapy in uterine fibroids (UFs) and to establish the risk factors of their occurrence. METHODS: We searched for original research studies evaluating MRgFUS therapy in UFs with outcomes containing AEs and/or complications in different databases (PubMed/MEDLINE, SCOPUS, COCHRANE) until March 2022. Reviews, editorials, opinions or letters, case studies, conference papers and abstracts were excluded from the analysis. The systematic literature search identified 446 articles, 43 of which were analyzed. RESULTS: According to available evidence, the overall incidence of serious complications in MRgFUS therapy is relatively low. No AEs/complications were reported in 11 out of 43 analyzed studies. The mean occurrence of all AEs in the analyzed material was 24.67%. The most commonly described AEs included pain, skin burns, urinary tract infections and sciatic neuropraxia. Major AEs, such as skin ulcerations or deep vein thrombosis, occurred in 0.41% of cases in the analyzed material. CONCLUSION: MRgFUS seems to be safe in UF therapy. The occurrence of AEs, especially major ones, is relatively low in comparison with other methods. The new devices and more experience of their users seem to reduce AE rate. The lack of unification in AE reporting and missing data are the main issues in this area. More prospective, randomized studies with unified reporting and long follow-up are needed to determine the safety in a long-term perspective.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Leiomioma , Imagem por Ressonância Magnética Intervencionista , Neoplasias Uterinas , Humanos , Feminino , Estudos Prospectivos , Resultado do Tratamento , Imagem por Ressonância Magnética Intervencionista/métodos , Leiomioma/diagnóstico por imagem , Leiomioma/terapia , Ablação por Ultrassom Focalizado de Alta Intensidade/efeitos adversos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética
12.
J Urol ; 208(1): 109-118, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35272477

RESUMO

PURPOSE: The aim of our study was to compare infectious complication rates between different prostate biopsy techniques with various number of biopsy cores. MATERIALS AND METHODS: In this retrospective study, all patients from 2 hospitals who underwent prostate biopsy between 2012 and 2019 were identified. Cohorts with different types of prostate biopsies were compiled within these hospitals. Primary outcome measure was any registered infectious complication within 7 days post-biopsy. Secondary outcomes were infectious complications within 30 days, hospitalization and bacteremia. To compare the risk of infection following different prostate biopsy techniques, data was fitted into a logistic regression model adjusting for potential confounders. RESULTS: In total, 4,233 prostate biopsies in 3,707 patients were included. After systematic transrectal ultrasound-guided prostate biopsy (TRUSPB; 12±1.4 biopsy cores), 4.0% (2,607) of all patients had infectious complications within 7 days post-biopsy. Transperineal magnetic resonance imaging (MRI)-ultrasound fusion guided prostate biopsy (16±3.7 biopsy cores) was associated with significantly lower infection rates than systematic TRUSPB (adjusted OR: 0.29 [0.09-0.73] 95% confidence interval [CI]). Transrectal targeted MRI-ultrasound fusion guided prostate biopsy (3.1±0.8 biopsy cores) and transrectal targeted in-bore MRI guided prostate biopsy (2.8±0.8 biopsy cores) also showed fewer infectious complications than systematic TRUSPB (adjusted OR: 0.41 [0.12-1.12] 95% CI and 0.68 [0.37-1.20] 95% CI, respectively). CONCLUSIONS: Transperineal prostate biopsy, or transrectal prostate biopsy with reduced number of biopsy cores, could lower the risk of infectious complications.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Neoplasias da Próstata , Humanos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Masculino , Próstata/patologia , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Ultrassonografia de Intervenção/métodos
13.
J Urol ; 207(2): 333-340, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34555925

RESUMO

PURPOSE: We assessed whether sampling of the transitional zone can be spared in patients with exclusively peripheral prostate cancer (PCa)-suspicious multiparametric magnetic resonance imaging (mpMRI) lesions who undergo combined mpMRI targeted (TBx) and systematic prostate biopsies (SBx). MATERIALS AND METHODS: Of 1,685 patients who underwent extended SBx including transitional zone sampling and had TBx of ≥1 lesion in the peripheral and/or transitional zone, we selected 863 patients with exclusively peripheral PCa-suspicious lesions and negative transitional zone mpMRI. Clinically significant PCa (csPCa) was defined as Gleason score (GS) ≥3+4. Within the selected cohort we performed a retrospective head-to-head comparison of csPCa detection rates between biopsy protocols: A) combination of peripheral TBx plus extended SBx including transitional zone sampling vs B) peripheral TBx plus SBx without any transitional zone sampling. Analyses were complemented with multivariable logistic regression models (LRMs) in the total cohort for predicting csPCa in SBx transitional zone sampling. RESULTS: Compared to the extended protocol (A), omission of systematic transitional zone sampling (B) yielded similar PCa detection for csPCa (48% vs 47%) and GS 3+3 (21% vs 20%). Only 2.0% csPCa was additionally detected with transitional zone SBx sampling (A). LRM confirmed that intraprostatic zonal distribution of mpMRI lesions independently influences csPCa detection rates of transitional zone SBx sampling. CONCLUSIONS: A peripheral TBx plus SBx without any transitional zone sampling protocol (B) yields similar csPCa detection rates as the standard extended protocol (A) but may reduce biopsy-related morbidity. This zone-dependent biopsy strategy warrants prospective evaluation to optimize the extent of systematic biopsies in presence of suspicious mpMRI lesions.


Assuntos
Imagem Multimodal/métodos , Imageamento por Ressonância Magnética Multiparamétrica , Próstata/patologia , Neoplasias da Próstata/diagnóstico , Idoso , Humanos , Biópsia Guiada por Imagem/métodos , Imagem por Ressonância Magnética Intervencionista , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Ultrassonografia
14.
NMR Biomed ; 35(4): e4231, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-31856431

RESUMO

Real-time interventional MRI (I-MRI) could help to visualize the position of the interventional feature, thus improving patient outcomes in MR-guided neurosurgery. In particular, in deep brain stimulation, real-time visualization of the intervention procedure using I-MRI could improve the accuracy of the electrode placement. However, the requirements of a high undersampling rate and fast reconstruction speed for real-time imaging pose a great challenge for reconstruction of the interventional images. Based on recent advances in deep learning (DL), we proposed a feature-based convolutional neural network (FbCNN) for reconstructing interventional images from golden-angle radially sampled data. The method was composed of two stages: (a) reconstruction of the interventional feature and (b) feature refinement and postprocessing. With only five radially sampled spokes, the interventional feature was reconstructed with a cascade CNN. The final interventional image was constructed with a refined feature and a fully sampled reference image. With a comparison of traditional reconstruction techniques and recent DL-based methods, it was shown that only FbCNN could reconstruct the interventional feature and the final interventional image. With a reconstruction time of ~ 500 ms per frame and an acceleration factor of ~ 80, it was demonstrated that FbCNN had the potential for application in real-time I-MRI.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Humanos , Imageamento por Ressonância Magnética/métodos , Redes Neurais de Computação
15.
J Cardiovasc Magn Reson ; 24(1): 32, 2022 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-35650624

RESUMO

INTRODUCTION: Cardiovascular magnetic resonance (CMR)-guided cardiac catheterization is becoming more widespread due to the ability to acquire both functional CMR measurements and diagnostic catheterization data without exposing patients to ionizing radiation. However, the real-time imaging sequences used for catheter guidance during these procedures are limited in resolution and the anatomical detail they can provide. In this study, we propose a passive catheter tracking approach which simultaneously improves catheter tracking and visualization of the anatomy. METHODS: 60 patients with congenital heart disease underwent CMR-guided cardiac catheterization on a 1.5T CMR scanner (Ingenia, Philips Healthcare, Best the Netherlands) using the Philips iSuite system. The proposed T1-overlay technique uses a commercially available heavily T1-weighted sequence to image the catheter, and overlays it on a high-resolution 3D dataset within iSuite in real-time. Suppressed tissue in the real-time images enables the use of a thick imaging slab to assist in tracking of the catheter. Improvement in catheter visualization time was compared between T1-overlay and the conventional invasive CMR (iCMR) balanced steady state free precession (bSSFP) sequence. This technique also enabled selective angiography visualization for real-time evaluation of blood flow dynamics (such as pulmonary transit time), similar to direct contrast injection under standard fluoroscopy. Estimates of pulmonary transit time using iCMR were validated using x-ray fluoroscopy in 16 patients. RESULTS: The T1-overlay approach significantly increased the time that the catheter tip was kept in view by the technologist compared to the bSSFP sequence conventionally used for iCMR. The resulting images received higher ratings for blood/balloon contrast, anatomy visualization, and overall suitability for iCMR guidance by three cardiologists. iCMR selective angiography using T1-overlay also provided accurate estimates of pulmonary transit time that agreed well with x-ray fluoroscopy. CONCLUSION: We demonstrate a new passive catheter tracking technique using the iSuite platform that improves visualization of the catheter and cardiac anatomy. These improvements significantly increase the time that the catheter tip is seen throughout the procedure. We also demonstrate the feasibility of iCMR selective angiography for the measurement of pulmonary transit time.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Cateterismo Cardíaco/métodos , Catéteres , Humanos , Imagem por Ressonância Magnética Intervencionista/métodos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes
16.
BMC Urol ; 22(1): 74, 2022 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-35513861

RESUMO

OBJECTIVES: To investigate the causes of missed diagnosis in mpMRI/TRUS fusion-guided targeted prostate biopsy. METHODS: The clinical data of 759 patients who underwent transperineal prostate biopsy from March 2021 to June 2021 at Nanjing DrumTower Hospital were retrospectively analyzed. Twenty-one patients had MRI contraindications. Ultimately, 738 patients completed mpMRI/TRUS fusion-guided targeted prostate biopsy + 12-core transperineal systematic biopsy after mpMRI and PI-RADS scoring. The pathological diagnoses from targeted and systematic biopsy were compared to evaluate and analyze the reasons for missed diagnoses in targeted biopsy. RESULTS: A total of 388 prostate cancer patients were identified, including 37 (9%) missed diagnoses with targeted biopsy and 44 (11.34%) with systematic biopsy. Between the target biopsy missed diagnosis group and not missed diagnosis group, there was no significant difference in age (71.08 ± 7.11 vs. 71.80 ± 7.94), but PSA (13.63 ± 12.41 vs. 54.54 ± 177.25 ng/ml), prostate volume (61.82 ± 40.64 vs. 44.34 ± 25.07 cm3), PSAD (0.27 ± 0.28 vs. 1.07 ± 2.91), and ISUP grade [1(1) vs. 3(2)] were significantly different. The pathological results of the 37 targeted biopsy missed diagnoses were recompared with MRI: 21 prostate cancers were normal on MRI; 9 cancer areas were abnormal on MRI; and 7 cancer areas on MRI were PI-RADS 3. CONCLUSIONS: Early prostate cancer, large prostate, effect of local anesthesia, doctor-patient cooperation, MRI diagnosis, and operator technology were possible factors for missed diagnosis in targeted biopsy. Improvements imaging technology, greater experience, and personalized biopsy may lead to an accurate pathological diagnosis.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Humanos , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Masculino , Diagnóstico Ausente , Estudos Prospectivos , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Ultrassonografia de Intervenção/métodos
17.
MAGMA ; 35(4): 523-532, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35596009

RESUMO

Multiparametric MRI of the prostate gland has become the initial evaluation of biopsy naïve men with a clinical suspicion for prostate cancer. PI-RADS 2.1 is a joint initiative and framework for prostate MRI acquisition and reporting, which aims to standardize technique and interpretation across centers. Building upon experience accrued following the introduction of PI-RADS 2.0, version 2.1 provides key updates and important clarifications, although it is intended to be an active document, which continues to be updated. Continued advances in our understanding of prostate cancer and progress in imaging technology will undoubtedly shape future iterations of the reporting system.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Humanos , Imageamento por Ressonância Magnética/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Masculino , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia
18.
Neurosurg Rev ; 45(2): 1421-1429, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34613525

RESUMO

Glioblastoma is the most common primary malignant brain tumor with an incidence of 5/100,000 inhabitants/year and a 5-year survival rate of 6.8%. Despite recent advances in the molecular biology understanding of glioblastoma, CNS chemotherapy remains challenging because of the impermeable blood-brain barrier (BBB). Interventional MRI-guided brain cryotherapy (IMRgC) is technique that creates a tissue lesion by making a severe targeted hypothermia and possibly a BBB disruption. This study goal was to analyze the effect of IMRgC on human BBB glioblastoma through its gadolinium enhancing features. All patients harboring a local glioblastoma recurrence and meeting all the inclusion criteria were consecutively included into this retrospective study during a 2-year period. The primary endpoint was to analyze the modification of the gadolinium enhancement on MRI T1 sequences using MR perfusion weighted images during follow-up. The secondary endpoint was to assess any ischemic/hemorrhagic complication following cryotherapy procedure using diffusion weighted imaging (DWI), susceptibility weighted imaging (SWI), or fluid-attenuated inversion recovery (FLAIR). Among the 6 patients studied, all (100%) showed a BBB disruption on the cryotherapy site through the analysis of the perfusion weighted images with an average delay of 2.83 months following the procedure. The gadolinium enhancement located around the cavity then spontaneously decreased in 4/6 patients (67%). No ischemic or hemorrhagic complication was recorded. This study confirms the IMRgC capacity to disrupt BBB as already suggested by the literature. IMRgC might represent a new option in the management of GBM allowing the combined effect of direct cryoablation and enhanced chemotherapy.


Assuntos
Neoplasias Encefálicas , Glioblastoma , Imagem por Ressonância Magnética Intervencionista , Barreira Hematoencefálica/patologia , Encéfalo/patologia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/terapia , Meios de Contraste , Crioterapia , Gadolínio , Glioblastoma/diagnóstico por imagem , Glioblastoma/terapia , Humanos , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos
19.
Urol Int ; 106(1): 83-89, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34350895

RESUMO

INTRODUCTION: Active surveillance (AS) strategies were established to avoid overtreatment of low-risk prostate cancer (PCa) patients. Low tumor volume represents one indication criteria; however, applying this criterion after MRI-targeted prostate biopsies may lead to overestimation of tumor volume; wherefore, patients suitable for AS would be exposed to the risk of overtreatment. METHODS: This retrospective analysis included 318 patients in which PCa was detected by MRI-TRUS fusion prostate biopsy. Classic and extended indication for AS included Gleason 6 and Gleason 3 + 4 cancer, respectively. We assessed the effect of targeted biopsies and temporary rating strategies on eligibility for AS and developed new "composite" algorithms to more accurately assess eligibility for AS. RESULTS: Forty-four (13.8%) and 60 (18.9%) of the 318 patients qualified for AS according to "classic" and "extended" criteria, respectively. Application of the "composite 1" definition led to AS eligibility of 52 of 248 patients (20.97%) in the classic and of 77 of 248 patients (31.05%) in the "extended" group. CONCLUSIONS: We could demonstrate that classic algorithms led to ineligibility of patients for AS. We propose a new rating algorithm to improve tumor assessment for a more accurate indication for AS.


Assuntos
Biópsia Guiada por Imagem , Imagem por Ressonância Magnética Intervencionista , Neoplasias da Próstata/patologia , Conduta Expectante , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Sobretratamento , Estudos Retrospectivos
20.
Urol Int ; 106(1): 90-96, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34404057

RESUMO

INTRODUCTION: There is still a lack of availability of high-quality multiparametric magnetic resonance imaging (mpMRI) interpreted by experienced uro-radiologists to rule out clinically significant PC (csPC). Consequently, we developed a new imaging method based on computed tomographic ultrasound (US) supported by artificial neural network analysis (ANNA). METHODS: Two hundred and two consecutive patients with visible mpMRI lesions were scanned and recorded by robotic CT-US during mpMRI-TRUS biopsy. Only significant index lesions (ISUP ≥2) verified by whole-mount pathology were retrospectively analyzed. Their visibility was reevaluated by 2 blinded investigators by grayscale US and ANNA. RESULTS: In the cohort, csPC was detected in 105 cases (52%) by mpMRI-TRUS biopsy. Whole-mount histology was available in 44 cases (36%). In this subgroup, mean PSA level was 8.6 ng/mL, mean prostate volume was 33 cm3, and mean tumor volume was 0.5 cm3. Median PI-RADS and ISUP of index lesions were 4 and 3, respectively. Index lesions were visible in grayscale US and ANNA in 25 cases (57%) and 30 cases (68%), respectively. Combining CT-US-ANNA, we detected index lesions in 35 patients (80%). CONCLUSIONS: The first results of multiparametric CT-US-ANNA imaging showed promising detection rates in patients with csPC. US imaging with ANNA has the potential to complement PC diagnosis.


Assuntos
Biópsia Guiada por Imagem , Imagem por Ressonância Magnética Intervencionista , Redes Neurais de Computação , Prostatectomia/métodos , Neoplasias da Próstata/cirurgia , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia de Intervenção/métodos , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Reto , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa