Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Chem Chem Phys ; 26(27): 19008-19020, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38953886

RESUMO

Improved molecular strong-field approximation theory is used to calculate the ionisation probability for the high-order above-threshold ionisation process induced by a few-cycle pulse with two carrier frequencies and one envelope. The asymmetry in the photoelectron momentum distribution is due to the ultrashort nature of the driving pulse and due to the relative orientation of the molecule with respect to the laser field. We introduce the generalised asymmetry parameter, which can be used to quantitatively measure the asymmetry between the photoelectron spectra along arbitrarily many selected directions. We investigate the difference between the asymmetry parameters calculated for atomic and molecular targets and show that the contributions to the asymmetry strongly depend on the type of the employed driving pulse. For the driving pulse with components that are linearly polarised with mutually orthogonal polarisations, we find that the main source of the asymmetry, especially in the high-energy part of the spectrum, is the ultrashort nature of the pulse. The relative orientation of the molecule with respect to the laser pulse only affects the low- and medium-energy parts of the spectrum. On the other hand, for the driving pulse with circularly polarised counterrotating components, the asymmetry introduced by molecular orientation is more pronounced. We also analyse the influence of the characteristics of molecular orbitals on the asymmetries using the examples of N2 and O2 molecules.

2.
J Phys Chem A ; 127(39): 8209-8219, 2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37733609

RESUMO

Using a strong-field-approximation theory, we investigate the high-order above-threshold ionization of diatomic molecules exposed to the monochromatic and bichromatic elliptically polarized fields. We devote particular attention to the difference between the photoelectron momentum distributions obtained with fields with opposite helicity. This difference is quantified using the elliptic-dichroism parameter, which represents the normalized difference between the differential ionization rates calculated with driving fields with opposite helicity. We find that this parameter strongly depends on the molecular orientation with respect to the laser field. In addition, this dependence is different for molecules with different types of highest-occupied molecular orbital. In other words, we show that the molecular structure is imprinted onto the elliptic-dichroism parameter for both monochromatic and bichromatic driving fields. This is explained by analyzing the interferences between various partial contributions to the differential ionization rate. In this way, elliptic dichroism also serves as a tool to analyze the electron dynamics. Finally, for heteronuclear diatomic molecules, we show that the elliptic dichroism is different from zero even for the direct electrons, i.e., the electrons that after liberation go directly to the detector. In this case, the dependence on the molecular orientation is far more pronounced for a bichromatic driving field.

3.
Diagnostics (Basel) ; 14(6)2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38535063

RESUMO

A Computed Tomography Urography (CTU) scan is a medical imaging test that examines the urinary tract, including the bladder, kidneys, and ureters. It helps diagnose various urinary tract diseases with precision. However, patients undergoing CTU imaging receive a relatively high dose of radiation, which can be a concern. In our research paper, we analyzed the Computed Tomography Dose Index (CTDIvol) and Dose-Length Product (DLP) for 203 adult patients who underwent CTU at one of the most important regional centers in Bosnia and Herzegovina that sees a large number of patients. Our study included the distribution of age and sex, the number of phases within one examination, and different clinical indications. We compared our findings with the results available in the scientific literature, particularly the recently published results from 20 European countries. Furthermore, we established the local diagnostic reference levels (LDRLs) that can help set the national diagnostic reference levels (NDRLs). We believe our research is a significant step towards optimizing the protocols used in different hospitals in our country.

4.
Diagnostics (Basel) ; 13(2)2023 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-36673137

RESUMO

Computed tomography (CT) is a diagnostic imaging process that uses ionising radiation to obtain information about the interior anatomic structure of the human body. Considering that the medical use of ionising radiation implies exposing patients to radiation that may lead to unwanted stochastic effects and that those effects are less probable at lower doses, optimising imaging protocols is of great importance. In this paper, we used an assembled 3D-printed infant head phantom and matched its image quality parameters with those obtained for a commercially available adult head phantom using the imaging protocol dedicated for adult patients. In accordance with the results, an optimised scanning protocol was designed which resulted in dose reductions for paediatric patients while keeping image quality at an adequate level.

5.
Diagnostics (Basel) ; 12(8)2022 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-36010362

RESUMO

For more than two years, coronavirus disease 19 (COVID-19) has represented a threat to global health and lifestyles. Computed tomography (CT) imaging provides useful information in patients with COVID-19 pneumonia. However, this diagnostic modality is based on exposure to ionizing radiation, which is associated with an increased risk of radiation-induced cancer. In this study, we evaluated the common dose descriptors, CTDIvol and DLP, for 1180 adult patients. This data was used to estimate the effective dose, and risk of exposure-induced death (REID). Awareness of the extensive use of CT as a diagnostic tool in the management of COVID-19 during the pandemic is vital for the evaluation of radiation exposure parameters, dose reduction methods development and radiation protection.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA