RESUMO
ß-arrestins regulate many cellular functions including intracellular signaling and desensitization of G protein-coupled receptors (GPCRs). Previous studies show that ß-arrestin signaling and receptor endocytosis are modulated by the plasma membrane phosphoinositide lipid phosphatidylinositol-(4, 5)-bisphosphate (PI(4,5)P2). We found that ß-arrestin also helped promote synthesis of PI(4,5)P2 and up-regulated GPCR endocytosis. We studied these questions with the Gq-coupled protease-activated receptor 2 (PAR2), which activates phospholipase C, desensitizes quickly, and undergoes extensive endocytosis. Phosphoinositides were monitored and controlled in live cells using lipid-specific fluorescent probes and genetic tools. Applying PAR2 agonist initiated depletion of PI(4,5)P2, which then recovered during rapid receptor desensitization, giving way to endocytosis. This endocytosis could be reduced by various manipulations that depleted phosphoinositides again right after phosphoinositide recovery: PI(4)P, a precusor of PI(4,5)P2, could be depleted at either the Golgi or the plasma membrane (PM) using a recruitable lipid 4-phosphatase enzyme and PI(4,5)P2 could be depleted at the PM using a recruitable 5-phosphatase. Endocytosis required the phosphoinositides. Knock-down of ß-arrestin revealed that endogenous ß-arrestin normally doubles the rate of PIP5-kinase (PIP5K) after PAR2 desensitization, boosting PI(4,5)P2-dependent formation of clathrin-coated pits (CCPs) at the PM. Desensitized PAR2 receptors were swiftly immobilized when they encountered CCPs, showing a dwell time of â¼90 s, 100 times longer than for unactivated receptors. PAR2/ß-arrestin complexes eventually accumulated around the edges or across the surface of CCPs promoting transient binding of PIP5K-Iγ. Taken together, ß-arrestins can coordinate potentiation of PIP5K activity at CCPs to induce local PI(4,5)P2 generation that promotes recruitment of PI(4,5)P2-dependent endocytic machinery.
Assuntos
Fosfatidilinositol 4,5-Difosfato/metabolismo , Receptores Acoplados a Proteínas G/metabolismo , beta-Arrestinas/metabolismo , Arrestinas/metabolismo , Membrana Celular/metabolismo , Clatrina/metabolismo , Endocitose/fisiologia , Células HEK293 , Humanos , Fosfatidilinositol 4,5-Difosfato/fisiologia , Fosfatidilinositóis/metabolismo , Fosforilação , Ligação Proteica , Receptor PAR-2/metabolismo , Receptores Acoplados a Proteínas G/fisiologia , Transdução de Sinais , beta-Arrestina 1/metabolismo , beta-Arrestinas/fisiologiaRESUMO
Immunophenotyping of vesicles, such as extracellular vesicles (EVs), is essential to understanding their origin and biological role. We previously described a custom-built flow analyzer that utilizes a gravity-driven flow, high numerical aperture objective, and micrometer-sized flow channels to reach the sensitivity needed for fast multidimensional analysis of the surface proteins of EVs, even down to the smallest EVs (e.g., â¼30-40 nm). It is difficult to flow focus small EVs, and thus, the transiting EVs exhibit a distribution in particle velocities due to the laminar flow. This distribution of vesicle velocities leads to potentially incorrect results when immunophenotyping nanometer-sized vesicles using cross-correlation analysis (Xcorr), as the order of appearance of the vesicles might not be the same at different spatially offset laser excitation regions. Here, we describe an alternative cross-correlation analysis strategy (Scorr), which uses information on particle transit time across the laser excitation beam width to improve multicolor colocalization in single-vesicle immunoprofiling. We tested the performance of the algorithm for colocalization analysis of multicolor nanobeads and EVs experimentally and via simulations and found that Scorr improved both the efficiency and accuracy of colocalization versus Xcorr. As shown from Monte Carlo simulations, Scorr provided an â¼1.2-4.7-fold increase in the number of colocalized peaks and ensured negligible colocalization of peaks. In silico results were in good agreement with experimental data, which showed an increase in colocalized peaks of â¼1.3-2.5-fold and â¼1.2-2-fold for multicolor beads and EVs, respectively.
Assuntos
Vesículas Extracelulares , Citometria de Fluxo/métodos , Vesículas Extracelulares/metabolismo , Luz , ImunofenotipagemRESUMO
The spatial resolution of single-molecule localization microscopy is limited by the photon number of a single switching event because of the difficulty of correlating switching events dispersed in time. Here we overcome this limitation by developing a new class of photoswitching semiconducting polymer dots (Pdots) with structured and highly dispersed single-particle spectra. We imaged the Pdots at the first and the second vibronic emission peaks and used the ratio of peak intensities as a spectral coding. By correlating switching events using the spectral coding and performing 4-9 frame binning, we achieved a 2-3 fold experimental resolution improvement versus conventional superresolution imaging. We applied this method to count and map SV2 and proton ATPase proteins on synaptic vesicles (SVs). The results reveal that these proteins are trafficked and organized with high precision, showing unprecedented level of detail about the composition and structure of SVs.
Assuntos
Pontos Quânticos , Semicondutores , Proteínas de Membrana , Vesículas Sinápticas , Pontos Quânticos/química , Diagnóstico por Imagem , Polímeros/química , Corantes Fluorescentes/químicaRESUMO
Optical sensors have attracted a great deal of interest for glucose detection. However, their practical applications for continuous glucose monitoring are still constrained by operational reliability in subcutaneous tissues. Here, we show an implantable hydrogel platform embedded with luminescent polymer dots (Pdots) for sensitive and long-term glucose monitoring. We use Pdot transducer in a polyacrylamide hydrogel matrix to construct an implantable platform. The hydrogel-Pdot transducer showed bright luminescence with ratiometric response to glucose changes. The in vitro and in vivo sensitivities of the hydrogel implant were enhanced by varying the enzyme concentration and injection volume. After implantation, the hydrogel with Pdot transducer remained at the implanted site without migration for 1 month and can be removed from the subcutaneous tissue for further analysis. Our results indicate that the hydrogel-Pdot platform maintains the intrinsic sensing property with excellent stability during 1 month implantation, while fibrous capsule formation on the implant in some cases needs to be solved for long-term continuous glucose monitoring.
Assuntos
Hidrogéis , Polímeros , Glicemia/análise , Automonitorização da Glicemia , Glucose , Reprodutibilidade dos Testes , TransdutoresRESUMO
Aberrant cerebral glucose metabolism is related to many brain diseases, especially brain tumor. However, it remains challenging to measure the dynamic changes in cerebral glucose. Here, we developed a near-infrared (NIR) optical transducer to sensitively monitor the glucose variations in cerebrospinal fluid in vivo. The transducer consists of an oxygen-sensitive nanoparticle combined with glucose oxidase (GOx), yielding highly sensitive NIR phosphorescence in response to blood glucose change. We demonstrated long-term continuous glucose monitoring by using the NIR transducer. After subcutaneous implantation, the glucose transducer provides a strong luminescence signal that can continuously monitor blood glucose fluctuations for weeks. By using the NIR emission of the transducer, we further observed abnormal dynamic changes in cerebrospinal fluid glucose and quantitatively assessed cerebral glucose uptake rates in transgenic mice bearing brain tumors. This study provides a promising method for the diagnosis of various metabolic diseases with altered glucose metabolism.
Assuntos
Neoplasias Encefálicas , Glucose , Animais , Glicemia , Automonitorização da Glicemia , Neoplasias Encefálicas/diagnóstico por imagem , Glucose Oxidase , Camundongos , Imagem Óptica , Oxigênio , Espectroscopia de Luz Próxima ao Infravermelho/métodos , TransdutoresRESUMO
Here, we developed a novel, multimode superresolution method to perform full-scale structural mapping and measure the energy landscape for single carrier transport along conjugated polymer nanowires. Through quenching of the local emission, the motion of a single photogenerated hole was tracked using blinking-assisted localization microscopy. Then, utilizing binding and unbinding dynamics of quenchers onto the nanowires, local emission spectra were collected sequentially and assembled to create a superresolution map of emission sites throughout the structure. The hole polaron trajectories were overlaid with the superresolution maps to correlate structures with charge transport properties. Using this method, we compared the efficiency of inter- and intrachain hole transport inside the nanowires and for the first time directly measured the depth of carrier traps originated from torsional disorder and chemical defects.
Assuntos
Nanofios , Microscopia , PolímerosRESUMO
Extracellular vesicles (EVs) are membranous particles released by most cells in our body, which are involved in many cell-to-cell signaling processes. Given the nanometer sizes and heterogeneity of EVs, highly sensitive methods with single-molecule resolution are fundamental to investigating their biophysical properties. Here, we demonstrate the sizing of EVs using a fluorescence-based flow analyzer with single-molecule sensitivity. Using a dye that selectively partitions into the vesicle's membrane, we show that the fluorescence intensity of a vesicle is proportional to its diameter. We discuss the constraints in sample preparation which are inherent to sizing nanoscale vesicles with a fluorescent membrane dye and propose several guidelines to improve data consistency. After optimizing staining conditions, we were able to measure the size of vesicles in the range â¼35-300 nm, covering the spectrum of EV sizes. Lastly, we developed a method to correct the signal intensity from each vesicle based on its traveling speed inside the microfluidic channel, by operating at a high sampling rate (10 kHz) and measuring the time required for the particle to cross the laser beam. Using this correction, we obtained a threefold greater accuracy in EV sizing, with a precision of ±15-25%.
Assuntos
Vesículas Extracelulares , Citometria de Fluxo , Corantes Fluorescentes , Luz , Coloração e RotulagemRESUMO
Single-cell manipulation, sorting, and dispensing into multiwell plates is useful for single-cell multiomics studies. Here, we develop a single-cell dispenser inspired by electrohydrodynamic jet printing that achieves accurate droplet generation and single-cell sorting and dispensing using fused silica capillary tubing as both the optical detection window and nozzle for droplet dispensing. Parameters that affect droplet dispensing performance-capillary inner and outer diameter, flow rate, applied voltage, and solution properties-were optimized systematically with COMSOL simulations and experimentation. Small (5-10 nL) droplets were obtained by using 100-µm inner diameter and 160-µm outer diameter capillary tubing and allowed efficient encapsulation and dispensing of single cells. We demonstrate an application of this easy-to-assemble single-cell dispenser by sorting and dispensing cells into multiwell plates for single-cell PCR analysis.
Assuntos
Dióxido de Silício , Análise de Célula Única , Separação Celular , Reação em Cadeia da Polimerase , Impressão TridimensionalRESUMO
Continuous glucose monitoring (CGM) allows type I and II diabetes patients to track changes in their glucose levels, allowing detection of impending hypoglycemia or hyperglycemia. Polymer dots (Pdots) are candidates for use in implanted CGM systems due to their exceptional brightness, photostability, sensitivity, and biocompatibility. However, Pdot glucose transducers are oxygen-dependent, and changes in tissue oxygen levels affect their measurement accuracy. Here, we describe an external ratiometric calibration method that corrects for changes in tissue oxygen levels to improve measurement accuracy. This method uses the ratio of oxygen concentrations inside and outside the Pdot glucose transducer as an indicator of glucose concentration to correct for signal deviations caused by tissue oxygen fluctuations. A second oxygen-sensitive Pdot that is not conjugated with glucose oxidase is used to measure the oxygen concentration outside the Pdot glucose transducer. We describe the theoretical basis for this approach and demonstrate its effectiveness experimentally in a subcutaneous mouse implant model. This external ratiometric system achieves higher accuracy glucose measurements than previous Pdot-based CGM systems and comparable accuracy to current commercial CGM systems, demonstrating the utility of the external ratiometric calibration strategy.
Assuntos
Glicemia/análise , Calibragem , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Transdutores , Animais , Feminino , Corantes Fluorescentes , Camundongos , Camundongos Endogâmicos BALB C , PolímerosRESUMO
Isolation and analysis of circulating rare cells is a promising approach for early detection of cancer and other diseases and for prenatal diagnosis. Isolation of rare cells is usually difficult due to their heterogeneity as well as their low abundance in peripheral blood. We previously reported a two-stage ensemble-decision aliquot ranking platform (S-eDAR) for isolating circulating tumor cells from whole blood with high throughput, high recovery rate (>90%), and good purity (>70%), allowing detection of low surface antigen-expressing cancer cells linked to metastasis. However, due to the scarcity of these cells, large sample volumes and large quantities of antibodies were required to isolate sufficient cells for downstream analysis. Here, we drastically increased the number of nucleated cells analyzed by first concentrating peripheral blood mononuclear cells (PBMCs) from whole blood by density gradient centrifugation. The S-eDAR platform was capable of isolating rare cells from concentrated PBMCs (108/mL, equivalent to processing â¼20 mL of whole blood in the 1 mL sample volume used by our instrument) at a high recovery rate (>85%). We then applied the S-eDAR platform for isolating rare fetal nucleated red blood cells (fNRBCs) from concentrated PBMCs spiked with umbilical cord blood cells and confirmed fNRBC recovery by immunostaining and fluorescence in situ hybridization, demonstrating the potential of the S-eDAR system for isolating rare fetal cells from maternal PBMCs to improve noninvasive prenatal diagnosis.
Assuntos
Leucócitos Mononucleares , Células Neoplásicas Circulantes , Separação Celular , Feminino , Sangue Fetal , Humanos , Hibridização in Situ Fluorescente , Leucócitos , GravidezRESUMO
Cervical cancer is the fourth-leading cause of cancer deaths among women worldwide and most cases occur in developing countries. Detection of high-risk (HR) HPV, the etiologic agent of cervical cancer, is a primary screening method for cervical cancer. However, the current gold standard for HPV detection, real-time PCR, is expensive, time-consuming, and instrumentation-intensive. A rapid, low-cost HPV detection method is needed for cervical cancer screening in low-resource settings. We previously developed a digital loop-mediated isothermal amplification (dLAMP) assay for rapid, quantitative detection of nucleic acids without the need for thermocycling. This assay employs a microfluidic self-digitization chip to automatically digitize a sample into an array of nanoliter wells in a simple assay format. Here we evaluate the dLAMP assay and self-digitization chip for detection of the commonly tested 14 high-risk HPVs in clinical samples. The dLAMP platform provided reliable genotyping and quantitative detection of the 14 high-risk HPVs with high sensitivity, demonstrating its potential for simple, rapid, and low-cost diagnosis of HPV infection.
Assuntos
Alphapapillomavirus , Neoplasias do Colo do Útero , Detecção Precoce de Câncer , Feminino , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido NucleicoRESUMO
A method for high-throughput counting and superresolution mapping of surface proteins on exosomes is described. The method combines a single-molecule sensitive flow technique and an adaptive superresolution imaging method. Exosomes stained with membrane dye and dye-conjugated antibodies were analyzed using a microfluidic platform at a flow rate of 100â exosome s-1 to determine size and protein copy number. Superresolution mapping was performed with exosomes labeled with novel transistor-like, semiconducting polymer dots (Pdots), which exhibit spontaneous blinking with <5â nm localization error and a broad range of optical-adjustable duty cycles. Based on the copy numbers extracted from the flow analysis, the switch-on frequency of the Pdots were finely adjusted so that structures of hundreds of exosomes were obtained within five minutes. The high throughput and high sensitivity of this method offer clear advantages for characterization of exosomes and similar biological vesicles.
Assuntos
Exossomos/metabolismo , Microfluídica/métodos , Tetraspaninas/análise , Anticorpos/química , Anticorpos/imunologia , Corantes Fluorescentes/química , Ensaios de Triagem em Larga Escala , Humanos , Polímeros/química , Pontos Quânticos/química , Semicondutores , Tetraspaninas/imunologiaRESUMO
Reduced nicotinamide adenine dinucleotide (NADH) is a key coenzyme in living cells due to its role as an electron carrier in redox reactions, and its concentration is an important indicator of cell metabolic state. Abnormal NADH levels are associated with age-related metabolic diseases and neurodegenerative disorders, creating a demand for a simple, rapid analytical method for point-of-care NADH sensing. Here we develop a series of NADH-sensitive semiconducting polymer dots (Pdots) as nanoprobes for NADH measurement, and test their performance in vitro and in vivo. NADH sensing is based on electron transfer from semiconducting polymer chains in the Pdot to NADH upon UV excitation, quenching Pdot fluorescence emission. In polyfluorene-based Pdots, this mechanism resulted in an on-off NADH sensor; in DPA-CNPPV Pdots, UV excitation resulted in NADH-sensitive emission at two wavelengths, enabling ratiometric detection. Ratiometric NADH detection using DPA-CNPPV Pdots exhibits high sensitivity (3.1â µM limit of detection), excellent selectivity versus other analytes, reversibility, and a fast response (less than 5â s). We demonstrate applications of the ratiometric NADH-sensing Pdots including smartphone-based NADH imaging for point-of-care use.
Assuntos
Fluorenos/química , Corantes Fluorescentes/química , NAD/análise , Polímeros/química , Pontos Quânticos/química , Algoritmos , Animais , Colorimetria/instrumentação , Colorimetria/métodos , Feminino , Humanos , Limite de Detecção , Células MCF-7 , Camundongos Endogâmicos BALB C , Camundongos Nus , NAD/química , Oxirredução , Testes Imediatos , Smartphone , Espectrometria de FluorescênciaRESUMO
We introduce an NAD(P)H-sensitive polymer dot (Pdot) biosensor for point-of-care monitoring of metabolites. The Pdot is combined with a metabolite-specific NAD(P)H-dependent enzyme that catalyzes the oxidation of the metabolite, generating NAD(P)H. Upon UV illumination, the NAD(P)H quenches the fluorescence emission of Pdot at 627â nm via electron transfer, and also fluoresces at 458â nm, resulting in a shift from red to blue emission at higher NAD(P)H concentrations. Metabolite concentration is quantified ratiometrically-based on the ratio of blue-to-red channel emission intensities, with a digital camera-with high sensitivity and specificity. We demonstrate phenylalanine biosensing in human plasma for a phenylketonuria screening test, quantifying several other disease-related metabolites (lactate, glucose, glutamate, and ß-hydroxybutyrate), and a paper-based assay with smartphore imaging for point-of-care use.
Assuntos
Aminoácido Oxirredutases/metabolismo , NADP/metabolismo , Polímeros/metabolismo , Aminoácido Oxirredutases/química , Técnicas Biossensoriais , Humanos , Estrutura Molecular , NADP/química , Polímeros/químicaRESUMO
In a conjugated polymer-based single-particle heterojunction, stochastic fluctuations of the photogenerated hole population lead to spontaneous fluorescence switching. We found that 405â nm irradiation can induce charge recombination and activate the single-particle emission. Based on these phenomena, we developed a novel class of semiconducting polymer dots that can operate in two superresolution imaging modes. The spontaneous switching mode offers efficient imaging of large areas, with <10â nm localization precision, while the photoactivation/deactivation mode offers slower imaging, with further improved localization precision (ca. 1â nm), showing advantages in resolving small structures that require high spatial resolution. Superresolution imaging of microtubules and clathrin-coated pits was demonstrated, under both modes. The excellent localization precision and versatile imaging options provided by these nanoparticles offer clear advantages for imaging of various biological systems.
Assuntos
Polímeros/química , Semicondutores , Clatrina/metabolismo , Invaginações Revestidas da Membrana Celular/metabolismo , Fluorescência , Microscopia de Fluorescência , Microtúbulos/metabolismoRESUMO
We present a method to determine the concentration of nucleic acids in a sample by partitioning it into droplets with a nonuniform volume distribution. This digital PCR method requires no special equipment for partitioning, unlike other methods that require nearly identical volumes. Droplets are generated by vortexing a sample in an immiscible oil to create an emulsion. PCR is performed, and droplets in the emulsion are imaged. Droplets with one or more copies of a nucleic acid are identified, and the nucleic acid concentration of the sample is determined. Numerical simulations of droplet distributions were used to estimate measurement error and dynamic range and to examine the effects of the total volume of droplets imaged and the shape of the droplet size distribution on measurement accuracy. The ability of the method to resolve 1.5- and 3-fold differences in concentration was assessed by using simulations of statistical power. The method was validated experimentally; droplet shrinkage and fusion during amplification were also assessed experimentally and showed negligible effects on measured concentration.
Assuntos
Reação em Cadeia da Polimerase/métodos , Estatística como Assunto , Emulsões , Dispositivos Lab-On-A-Chip , Distribuição de Poisson , Reação em Cadeia da Polimerase/instrumentaçãoRESUMO
The ability to sort and dispense droplets accurately is essential to droplet-based single-cell analysis. Here, we describe a fluorescence-activated single-droplet dispenser (FASD) that is analogous to a conventional fluorescence-activated cell sorter, but sorts droplets containing single cells within an oil emulsion. The FASD system uses cytometric detection and electrohydrodynamic actuation-based single-droplet manipulation, allowing droplet isolation and dispensing with high efficiency and accuracy. The system is compatible with multiwell plates and can be integrated with existing microfluidic devices and large-scale screening systems. By enabling sorting based on single-cell reactions such as PCR, this platform will help expand the basis of cell sorting from mainly protein biomarkers to nucleic acid sequences and secreted biomolecules.
Assuntos
Separação Celular/instrumentação , Citometria de Fluxo/instrumentação , Análise de Célula Única/instrumentação , Fluorescência , Humanos , Células K562 , Dispositivos Lab-On-A-ChipRESUMO
Isolation and analysis of circulating tumor cells (CTCs) from the blood of patients at risk of metastatic cancers is a promising approach to improving cancer treatment. However, CTC isolation is difficult due to low CTC abundance and heterogeneity. Previously, we reported an ensemble-decision aliquot ranking (eDAR) platform for the rare cell and CTC isolation with high throughput, greater than 90% recovery, and high sensitivity, allowing detection of low surface antigen-expressing cells linked to metastasis. Here we demonstrate a sequential eDAR platform capable of isolating rare cells from whole blood with high purity. This improvement in purity is achieved by using a sequential sorting and flow stretching design in which whole blood is sorted and fluid elements are stretched using herringbone features and the parabolic flow profile being sorted a second time. This platform can be used to collect single CTCs in a multiwell plate for downstream analysis.
Assuntos
Células Sanguíneas , Separação Celular/métodos , Células Neoplásicas Circulantes , Humanos , Dispositivos Lab-On-A-Chip , Células MCF-7 , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodosRESUMO
Bright long-wavelength-excitable semiconducting polymer dots (LWE-Pdots) are highly desirable for inâ vivo imaging and multiplexed inâ vitro bioassays. LWE-Pdots have been obtained by incorporating a near-infrared (NIR) emitter into the backbone of a polymer host to develop a binary donor-acceptor (D-A) system. However, they usually suffer from severe concentration quenching and a trade-off between fluorescence quantum yield (Φf ) and absorption cross-section (σ). Herein, we describe a ternary component (D1 /D2 -A) strategy to achieve ultrabright, green laser-excitable Pdots with narrow-band NIR emission by introducing a BODIPY-based assistant polymer donor as D1 . The D1 /D2 -A Pdots possess improved Φf and σ compared to corresponding binary D2 -A Pdots. Their Φf is as high as 40.2 %, one of the most efficient NIR Pdots reported. The D1 /D2 -A Pdots show ultrahigh single-particle brightness, 83-fold brighter than Qdot 705 when excited by a 532â nm laser. When injected into mice, higher contrast inâ vivo tumor imaging was achieved using the ternary Pdots versus the binary D-A Pdots.
Assuntos
Compostos de Boro/química , Raios Infravermelhos , Neoplasias Experimentais/patologia , Polímeros/química , Pontos Quânticos , Semicondutores , Animais , Fluorescência , CamundongosRESUMO
Semiconducting polymer dots (Pdots) as fluorescent probes have shown promising applications because of their excellent optical properties. However, apparent differences were observed in cytotoxicity assays, which might originate from impurities introduced in polymer synthesis or nanoparticle preparation. A simple gel-filtration-based purification method was used to address this issue. Purified Pdots displayed obviously decreased cytotoxicity as compared with the same batch of unpurified Pdots. The purified Pdots were further examined in a cytotoxicity study on mesenchymal stem cells (MSCs), which are very sensitive to exogenous probes. The results indicated that purified Pdots did not affect the proliferation ability of MSCs, while unpurified Pdots could have obvious cytotoxicity. In addition, the purified Pdots did not show cytotoxicity even after 6 months of storage. Our results demonstrated that gel filtration is an effective method for obtaining Pdots with minimal cytotoxicity, which are more suitable for biological applications.