Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
1.
Eur Heart J ; 45(20): 1783-1800, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38606889

RESUMO

Clinical risk scores based on traditional risk factors of atherosclerosis correlate imprecisely to an individual's complex pathophysiological predisposition to atherosclerosis and provide limited accuracy for predicting major adverse cardiovascular events (MACE). Over the past two decades, computed tomography scanners and techniques for coronary computed tomography angiography (CCTA) analysis have substantially improved, enabling more precise atherosclerotic plaque quantification and characterization. The accuracy of CCTA for quantifying stenosis and atherosclerosis has been validated in numerous multicentre studies and has shown consistent incremental prognostic value for MACE over the clinical risk spectrum in different populations. Serial CCTA studies have advanced our understanding of vascular biology and atherosclerotic disease progression. The direct disease visualization of CCTA has the potential to be used synergistically with indirect markers of risk to significantly improve prevention of MACE, pending large-scale randomized evaluation.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Humanos , Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico , Medição de Risco/métodos , Angiografia Coronária/métodos , Placa Aterosclerótica/diagnóstico por imagem , Fatores de Risco de Doenças Cardíacas , Prognóstico , Estenose Coronária/diagnóstico por imagem
2.
Heart Vessels ; 39(4): 299-309, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38367040

RESUMO

Fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) are invasive techniques used to evaluate the hemodynamic significance of coronary artery stenosis. These methods have been validated through perfusion imaging and clinical trials. New invasive pressure ratios that do not require hyperemia have recently emerged, and it is essential to confirm their diagnostic efficacy. The aim of this study was to validate the resting full-cycle ratio (RFR) and the diastolic pressure ratio (dPR), against [15O]H2O positron emission tomography (PET) imaging. A total of 129 symptomatic patients with an intermediate risk of coronary artery disease (CAD) were included. All patients underwent cardiac [15O]H2O PET with quantitative assessment of resting and hyperemic myocardial perfusion. Within a 2 week period, coronary angiography was performed. Intracoronary pressure measurements were obtained in 320 vessels and RFR, dPR, and FFR were computed. PET derived regional hyperemic myocardial blood flow (hMBF) and myocardial perfusion reserve (MPR) served as reference standards. In coronary arteries with stenoses (43%, 136 of 320), the overall diagnostic accuracies of RFR, dPR, and FFR did not differ when PET hyperemic MBF < 2.3 ml min-1 (69.9%, 70.6%, and 77.1%, respectively) and PET MPR < 2.5 (70.6%, 71.3%, and 66.9%, respectively) were considered as the reference for myocardial ischemia. Non-significant differences between the areas under the receiver operating characteristic (ROC) curve were found between the different indices. Furthermore, the integration of FFR with RFR (or dPR) does not enhance the diagnostic information already achieved by FFR in the characterization of ischemia via PET perfusion. In conclusion, the novel non-hyperemic pressure ratios, RFR and dPR, have a diagnostic performance comparable to FFR in assessing regional myocardial ischemia. These findings suggest that RFR and dPR may be considered as an FFR alternative for invasively guiding revascularization treatment in symptomatic patients with CAD.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Pressão Sanguínea , Cateterismo Cardíaco , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Valor Preditivo dos Testes
3.
Echocardiography ; 41(6): e15849, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38837443

RESUMO

Heart failure (HF) is a chronic and progressive disease that often progresses to an advanced stage where conventional therapy is insufficient to relieve patients' symptoms. Despite the availability of advanced therapies such as mechanical circulatory support or heart transplantation, the complexity of defining advanced HF, which requires multiple parameters and multimodality assessment, often leads to delays in referral to dedicated specialists with the result of a worsening prognosis. In this review, we aim to explore the role of cardiac magnetic resonance (CMR) in advanced HF by showing how CMR is useful at every step in managing these patients: from diagnosis to prognostic stratification, hemodynamic evaluation, follow-up and advanced therapies such as heart transplantation. The technical challenges of scanning advanced HF patients, which often require troubleshooting of intracardiac devices and dedicated scans, will be also discussed.


Assuntos
Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos
4.
Eur J Nucl Med Mol Imaging ; 50(13): 3897-3909, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37561140

RESUMO

PURPOSE: We sought to assess the impact of coronary revascularization on myocardial perfusion and fractional flow reserve (FFR) in patients without a cardiac history, with prior myocardial infarction (MI) or non-MI percutaneous coronary intervention (PCI). Furthermore, we studied the impact of scar tissue. METHODS: Symptomatic patients underwent [15O]H2O positron emission tomography (PET) and FFR before and after revascularization. Patients with prior CAD, defined as prior MI or PCI, underwent scar quantification by magnetic resonance imaging late gadolinium enhancement. RESULTS: Among 137 patients (87% male, age 62.2 ± 9.5 years) 84 (61%) had a prior MI or PCI. The increase in FFR and hyperemic myocardial blood flow (hMBF) was less in patients with prior MI or non-MI PCI compared to those without a cardiac history (FFR: 0.23 ± 0.14 vs. 0.20 ± 0.12 vs. 0.31 ± 0.18, p = 0.02; hMBF: 0.54 ± 0.75 vs. 0.62 ± 0.97 vs. 0.91 ± 0.96 ml/min/g, p = 0.04). Post-revascularization FFR and hMBF were similar across patients without a cardiac history or with prior MI or non-MI PCI. An increase in FFR was strongly associated to hMBF increase in patients without a cardiac history or with prior MI/non-MI PCI (r = 0.60 and r = 0.60, p < 0.01 for both). Similar results were found for coronary flow reserve. In patients with prior MI scar was negatively correlated to hMBF increase and independently predictive of an attenuated CFR increase. CONCLUSIONS: Post revascularization FFR and perfusion were similar among patients without a cardiac history, with prior MI or non-MI PCI. In patients with prior MI scar burden was associated to an attenuated perfusion increase.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Angiografia Coronária/métodos , Cicatriz/diagnóstico por imagem , Meios de Contraste , Resultado do Tratamento , Gadolínio , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/terapia
5.
Catheter Cardiovasc Interv ; 102(5): 844-856, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37671770

RESUMO

BACKGROUND: The Japanese Channel (J-Channel) score was introduced to aid in retrograde percutaneous coronary intervention (PCI) of chronic total coronary occlusions (CTOs). The predictive value of the J-Channel score has not been compared with established collateral grading systems such as the Rentrop classification and Werner grade. AIMS: To investigate the predictive value of the J-Channel score, Rentrop classification and Werner grade for successful collateral channel (CC) guidewire crossing and technical CTO PCI success. METHODS: A total of 600 prospectively recruited patients underwent CTO PCI. All grading systems were assessed under dual catheter injection. CC guidewire crossing was considered successful if the guidewire reached the distal segment of the CTO vessel through a retrograde approach. Technical CTO PCI success was defined as thrombolysis in myocardial infarction flow grade 3 and residual stenosis <30%. RESULTS: Of 600 patients, 257 (43%) underwent CTO PCI through a retrograde approach. Successful CC guidewire crossing was achieved in 208 (81%) patients. The predictive value of the J-Channel score for CC guidewire crossing (area under curve 0.743) was comparable with the Rentrop classification (0.699, p = 0.094) and superior to the Werner grade (0.663, p = 0.002). Technical CTO PCI success was reported in 232 (90%) patients. The Rentrop classification exhibited a numerically higher discriminatory ability (0.676) compared to the J-Channel score (0.664) and Werner grade (0.589). CONCLUSIONS: The J-channel score might aid in strategic collateral channel selection during retrograde CTO PCI. However, the J-Channel score, Rentrop classification, and Werner grade have limited value in predicting technical CTO PCI success.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Angiografia Coronária , Doença Crônica , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Fatores de Risco , Sistema de Registros
6.
J Nucl Cardiol ; 30(4): 1558-1569, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36645580

RESUMO

BACKGROUND: Positron emission tomography (PET) is the clinical gold standard for quantifying myocardial blood flow (MBF). Pericoronary adipose tissue (PCAT) attenuation may detect vascular inflammation indirectly. We examined the relationship between MBF by PET and plaque burden and PCAT on coronary CT angiography (CCTA). METHODS: This post hoc analysis of the PACIFIC trial included 208 patients with suspected coronary artery disease (CAD) who underwent [15O]H2O PET and CCTA. Low-attenuation plaque (LAP, < 30HU), non-calcified plaque (NCP), and PCAT attenuation were measured by CCTA. RESULTS: In 582 vessels, 211 (36.3%) had impaired per-vessel hyperemic MBF (≤ 2.30 mL/min/g). In multivariable analysis, LAP burden was independently and consistently associated with impaired hyperemic MBF (P = 0.016); over NCP burden (P = 0.997). Addition of LAP burden improved predictive performance for impaired hyperemic MBF from a model with CAD severity and calcified plaque burden (P < 0.001). There was no correlation between PCAT attenuation and hyperemic MBF (r = - 0.11), and PCAT attenuation was not associated with impaired hyperemic MBF in univariable or multivariable analysis of all vessels (P > 0.1). CONCLUSION: In patients with stable CAD, LAP burden was independently associated with impaired hyperemic MBF and a stronger predictor of impaired hyperemic MBF than NCP burden. There was no association between PCAT attenuation and hyperemic MBF.


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Estudos Prospectivos , Doença da Artéria Coronariana/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Tomografia por Emissão de Pósitrons , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Tecido Adiposo/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Valor Preditivo dos Testes
7.
Eur Heart J ; 43(33): 3118-3128, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35708168

RESUMO

AIMS: The diagnostic performance of non-invasive imaging in patients with prior coronary artery disease (CAD) has not been tested in prospective head-to-head comparative studies. The aim of this study was to compare the diagnostic performance of qualitative single-photon emission computed tomography (SPECT), quantitative positron emission tomography (PET), and qualitative magnetic resonance imaging (MRI) in patients with a prior myocardial infarction (MI) or percutaneous coronary intervention (PCI). METHODS AND RESULTS: In this prospective clinical study, all patients with prior MI and/or PCI and new symptoms of ischaemic CAD underwent 99mTc-tetrofosmin SPECT, [15O]H2O PET, and MRI, followed by invasive coronary angiography with fractional flow reserve (FFR) in all coronary arteries. All modalities were interpreted by core laboratories. Haemodynamically significant CAD was defined by at least one coronary artery with an FFR ≤0.80. Among the 189 enrolled patients, 63% had significant CAD. Sensitivity was 67% (95% confidence interval 58-76%) for SPECT, 81% (72-87%) for PET, and 66% (56-75%) for MRI. Specificity was 61% (48-72%) for SPECT, 65% (53-76%) for PET, and 62% (49-74%) for MRI. Sensitivity of PET was higher than SPECT (P = 0.016) and MRI (P = 0.014), whereas specificity did not differ among the modalities. Diagnostic accuracy for PET (75%, 68-81%) did not statistically differ from SPECT (65%, 58-72%, P = 0.03) and MRI (64%, 57-72%, P = 0.052). Using FFR < 0.75 as a reference, accuracies increased to 69% (SPECT), 79% (PET), and 71% (MRI). CONCLUSION: In this prospective head-to-head comparative study, SPECT, PET, and MRI did not show a significantly different accuracy for diagnosing FFR defined significant CAD in patients with prior PCI and/or MI. Overall diagnostic performances, however, were discouraging and the additive value of non-invasive imaging in this high-risk population is questionable.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Intervenção Coronária Percutânea , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Imagem de Perfusão do Miocárdio/métodos , Valor Preditivo dos Testes , Estudos Prospectivos , Tomografia Computadorizada por Raios X
8.
Curr Cardiol Rep ; 24(10): 1309-1325, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35925511

RESUMO

PURPOSE OF REVIEW: This review will outline the current evidence on the anatomical, functional, and physiological tools that may be applied in the evaluation of patients with late recurrent angina after coronary artery bypass grafting (CABG). Furthermore, we discuss management strategies and propose an algorithm to guide decision-making for this complex patient population. RECENT FINDINGS: Patients with prior CABG often present with late recurrent angina as a result of bypass graft failure and progression of native coronary artery disease (CAD). These patients are generally older, have a higher prevalence of comorbidities, and more complex atherosclerotic lesion morphology compared to CABG-naïve patients. In addition, guideline recommendations are based on studies in which post-CABG patients have been largely excluded. Several invasive and non-invasive diagnostic tools are currently available to assess graft patency, the hemodynamic significance of native CAD progression, left ventricular function, and myocardial viability. Such tools, in particular the latest generation coronary computed tomography angiography, are part of a systematic diagnostic work-up to guide optimal repeat revascularization strategy in patients presenting with late recurrent angina after CABG.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana , Angina Pectoris/diagnóstico , Angina Pectoris/etiologia , Angina Pectoris/terapia , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Humanos , Reoperação , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 97(4): 614-622, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32845067

RESUMO

OBJECTIVES: This study aimed to investigate the performance of computed tomography derived fractional flow reserve based interactive planner (FFRCT planner) to predict the physiological benefits of percutaneous coronary intervention (PCI) as defined by invasive post-PCI FFR. BACKGROUND: Advances in FFRCT technology have enabled the simulation of hyperemic pressure changes after virtual removal of stenoses. METHODS: In 56 patients (63 vessels) invasive FFR measurements before and after PCI were obtained and FFRCT was calculated using pre-PCI coronary CT angiography. Subsequently, FFRCT and invasive coronary angiography models were aligned allowing virtual removal of coronary stenoses on pre-PCI FFRCT models in the same locations as PCI was performed. Relationships between invasive FFR and FFRCT , between post-PCI FFR and FFRCT planner, and between delta FFR and delta FFRCT were evaluated. RESULTS: Pre PCI, invasive FFR was 0.65 ± 0.12 and FFRCT was 0.64 ± 0.13 (p = .34) with a mean difference of 0.015 (95% CI: -0.23-0.26). Post-PCI invasive FFR was 0.89 ± 0.07 and FFRCT planner was 0.85 ± 0.07 (p < .001) with a mean difference of 0.040 (95% CI: -0.10-0.18). Delta invasive FFR and delta FFRCT were 0.23 ± 0.12 and 0.21 ± 0.12 (p = .09) with a mean difference of 0.025 (95% CI: -0.20-0.25). Significant correlations were found between pre-PCI FFR and FFRCT (r = 0.53, p < .001), between post-PCI FFR and FFRCT planner (r = 0.41, p = .001), and between delta FFR and delta FFRCT (r = 0.57, p < .001). CONCLUSIONS: The non-invasive FFRCT planner tool demonstrated significant albeit modest agreement with post-PCI FFR and change in FFR values after PCI. The FFRCT planner tool may hold promise for PCI procedural planning; however, improvement in technology is warranted before clinical application.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X , Resultado do Tratamento
10.
J Interv Cardiol ; 2021: 4339451, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34548847

RESUMO

OBJECTIVES: Quantitative flow ratio (QFR) computes fractional flow reserve (FFR) based on invasive coronary angiography (ICA). Residual QFR estimates post-percutaneous coronary intervention (PCI) FFR. This study sought to assess the relationship of residual QFR with post-PCI FFR. METHODS: Residual QFR analysis, using pre-PCI ICA, was attempted in 159 vessels with post-PCI FFR. QFR lesion location was matched with the PCI location to simulate the performed intervention and allow computation of residual QFR. A post-PCI FFR < 0.90 was used to define a suboptimal PCI result. RESULTS: Residual QFR computation was successful in 128 (81%) vessels. Median residual QFR was higher than post-PCI FFR (0.96 Q1-Q3: 0.91-0.99 vs. 0.91 Q1-Q3: 0.86-0.96, p < 0.001). A significant correlation and agreement were observed between residual QFR and post-PCI FFR (R = 0.56 and intraclass correlation coefficient = 0.47, p < 0.001 for both). Following PCI, an FFR < 0.90 was observed in 54 (42%) vessels. Specificity, positive predictive value, sensitivity, and negative predictive value of residual QFR for assessment of the PCI result were 96% (95% confidence interval (CI): 87-99%), 89% (95% CI: 72-96%), 44% (95% CI: 31-59%), and 70% (95% CI: 65-75%), respectively. Residual QFR had an accuracy of 74% (95% CI: 66-82%) and an area under the receiver operating characteristic curve of 0.79 (95% CI: 0.71-0.86). CONCLUSIONS: A significant correlation and agreement between residual QFR and post-PCI FFR were observed. Residual QFR ≥ 0.90 did not necessarily commensurate with a satisfactory PCI (post-PCI FFR ≥ 0.90). In contrast, residual QFR exhibited a high specificity for prediction of a suboptimal PCI result.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos
11.
Arterioscler Thromb Vasc Biol ; 40(2): 462-472, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31801376

RESUMO

OBJECTIVE: Netrin-1 has been shown to play a role in the initiation of atherosclerosis in mice models. However, little is known about the role of Netrin-1 in humans. We set out to study whether Netrin-1 is associated with different stages of atherosclerosis. Approach and Results: Plasma Netrin-1 levels were measured in different patient cohorts: (1) 22 patients with high cardiovascular risk who underwent arterial wall inflammation assessment using positron-emission tomography / computed tomography, (2) 168 patients with a positive family history of premature atherosclerosis in whom coronary artery calcium scores were obtained, and (3) 104 patients with chest pain who underwent coronary computed tomography angiography imaging to evaluate plaque vulnerability and burden. Netrin-1 plasma levels were negatively correlated with arterial wall inflammation (ß, -0.01 [95% CI, 0.02 to -0.01] R2, 0.61; P<0.0001), and concentrations of Netrin-1 were significantly lower when atherosclerosis was present compared with individuals without atherosclerosis (28.01 versus 10.51 ng/mL, P<0.001). There was no difference in Netrin-1 plasma concentrations between patients with stable versus unstable plaques (11.17 versus 11.74 ng/mL, P=0.511). However, Netrin-1 plasma levels were negatively correlated to total plaque volume (ß, -0.09 [95% CI, -0.11 to -0.08] R2, 0.57, P<0.0001), calcified plaque volumes (ß, -0.10 [95% CI, -0.12 to -0.08] R2, 0.53; P<0.0001), and noncalcified plaque volumes (ß, -0.08 [95% CI, -0.10 to -0.06] R2, 0.41; P<0.0001). Treatment of inflammatory stimulated endothelial cells with plasma with high Netrin-1 level resulted in reduced endothelial inflammation and consequently, less monocyte adhesion. CONCLUSIONS: Netrin-1 plasma levels are lower in patients with subclinical atherosclerosis and in patients with arterial wall inflammation. Netrin-1 is not associated with plaque vulnerability; however, it is negatively correlated to plaque burden, suggesting that Netrin-1 is involved in some, but not all, stages of atherosclerosis.


Assuntos
Aterosclerose/sangue , Doença da Artéria Coronariana/sangue , Vasos Coronários/diagnóstico por imagem , Netrina-1/sangue , Aterosclerose/diagnóstico , Biomarcadores/sangue , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Prognóstico
12.
Eur J Nucl Med Mol Imaging ; 47(7): 1688-1697, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31822958

RESUMO

PURPOSE: To compare cardiac magnetic resonance imaging (CMR) with [15O]H2O positron emission tomography (PET) for quantification of absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) in patients with coronary artery disease (CAD). METHODS: Fifty-nine patients with stable CAD underwent CMR and [15O]H2O PET. The CMR imaging protocol included late gadolinium enhancement to rule out presence of scar tissue and perfusion imaging using a dual sequence, single bolus technique. Absolute MBF was determined for the three main vascular territories at rest and during vasodilator stress. RESULTS: CMR measurements of regional stress MBF and MFR showed only moderate correlation to those obtained using PET (r = 0.39; P < 0.001 for stress MBF and r = 0.36; P < 0.001 for MFR). Bland-Altman analysis revealed a significant bias of 0.2 ± 1.0 mL/min/g for stress MBF and - 0.5 ± 1.2 for MFR. CMR-derived stress MBF and MFR demonstrated area under the curves of respectively 0.72 (95% CI: 0.65 to 0.79) and 0.76 (95% CI: 0.69 to 0.83) and had optimal cutoff values of 2.35 mL/min/g and 2.25 for detecting abnormal myocardial perfusion, defined as [15O]H2O PET-derived stress MBF ≤ 2.3 mL/min/g and MFR ≤ 2.5. Using these cutoff values, CMR and PET were concordant in 137 (77%) vascular territories for stress MBF and 135 (80%) vascular territories for MFR. CONCLUSION: CMR measurements of stress MBF and MFR showed modest agreement to those obtained with [15O]H2O PET. Nevertheless, stress MBF and MFR were concordant between CMR and [15O]H2O PET in 77% and 80% of vascular territories, respectively.


Assuntos
Doença da Artéria Coronariana , Circulação Coronária , Espectroscopia de Ressonância Magnética , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Idoso , Meios de Contraste , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Reserva Fracionada de Fluxo Miocárdico , Gadolínio , Humanos , Espectroscopia de Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/normas , Radioisótopos de Oxigênio , Tomografia por Emissão de Pósitrons/normas , Reprodutibilidade dos Testes
13.
Catheter Cardiovasc Interv ; 93(6): 1059-1066, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30430715

RESUMO

BACKGROUND: The benefits of chronic coronary total occlusion (CTO) percutaneous coronary intervention (PCI) are being questioned. The aim of this study was to assess the effects of CTO PCI on absolute myocardial perfusion, as compared with PCI of hemodynamically significant non-CTO lesions. METHODS: Consecutive patients with a preserved left ventricular ejection fraction (≥50%) and a CTO or non-CTO lesion, in whom [15 O]H2 O positron emission tomography was performed prior and after successful PCI, were included. Change in quantitative (hyperemic) myocardial blood flow (MBF), coronary flow reserve (CFR) and perfusion defect size (in myocardial segments) were compared between CTOs and non-CTO lesions. RESULTS: In total 92 patients with a CTO and 31 patients with a non-CTO lesion were included. CTOs induced larger perfusion defect sizes (4.51 ± 1.69 vs. 3.23 ± 2.38 segments, P < 0.01) with lower hyperemic MBF (1.30 ± 0.37 vs. 1.58 ± 0.62 mL·min-1 ·g-1 , P < 0.01) and similarly impaired CFR (1.66 ± 0.75 vs. 1.89 ± 0.77, P = 0.17) compared with non-CTO lesions. After PCI both hyperemic MBF and CFR increased similarly between groups (P = 0.57 and 0.35) to normal ranges with higher hyperemic MBF values in non-CTO compared with CTO (2.89 ± 0.94 vs. 2.48 ± 0.73 mL·min-1 ·g-1 , P = 0.03). Perfusion defect sizes decreased similarly after CTO PCI and non-CTO PCI (P = 0.14), leading to small residual defect sizes in both groups (1.15 ± 1.44 vs. 0.61 ± 1.45 segments, P = 0.054). CONCLUSIONS: Myocardial perfusion findings are slightly more hampered in patients with a CTO before and after PCI. Percutaneous revascularization of CTOs, however, improves absolute myocardial perfusion similarly to PCI of hemodynamically significant non-CTO lesions, leading to satisfying results.


Assuntos
Oclusão Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Hemodinâmica , Imagem de Perfusão do Miocárdio , Intervenção Coronária Percutânea , Tomografia por Emissão de Pósitrons , Idoso , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
15.
Eur Heart J ; 39(46): 4072-4081, 2018 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-30452609

RESUMO

Aims: Guidelines recommend the use of fractional flow reserve (FFR) to guide percutaneous coronary intervention. For this purpose, physiological lesion assessment without adenosine may have a similar diagnostic accuracy as FFR. We aimed to investigate the performances of FFR, resting instantaneous wave-free ratio (iFR), and resting Pd/Pa compared with [15O]H2O positron emission tomography (PET) perfusion imaging. Methods and results: [15O]H2O PET and intracoronary pressure measurements were evaluated in 320 coronary arteries (of which 136 coronary stenoses) in 129 stable patients. The primary analysis consisting of the area-under-the-receiver-operating-characteristic curve for impaired PET hyperaemic myocardial blood flow (MBF) <2.3 mL⋅min-1⋅g-1 in coronary stenoses was 0.78 [95% confidence interval (CI): 0.70-0.85] for FFR, 0.74 (95% CI: 0.66-0.81) for iFR, and 0.75 (95% CI: 0.67-0.82) for Pd/Pa. No significant differences between area-under-the-receiver-operating-characteristic curve were observed for any two indices compared. In a secondary analysis, the diagnostic accuracy compared with impaired PET hyperaemic MBF in coronary stenoses was 72% (95% CI: 64-79%, κ: 0.44) for FFR ≤0.80, 72% (95% CI: 64-80%, κ: 0.44) for iFR ≤0.89, and 70% (95% CI: 62-78%, κ: 0.40) for Pd/Pa ≤0.92. Other secondary analyses included a comparison of physiological indices with PET hyperaemic MBF in all vessels and all of the aforementioned analyses using PET myocardial perfusion reserve as comparator. Statistical testing for the secondary analyses showed results that were consistent with the results of the primary analysis. Conclusion: Fractional flow reserve, iFR, and Pd/Pa showed a similar performance when compared with PET imaging. Our results support the validity of invasive physiological lesion assessment under resting conditions by iFR or Pd/Pa. Trial registration: Sub-study of the PACIFIC trial with clinicaltrials.gov identifier: NCT01521468.


Assuntos
Pressão Arterial/fisiologia , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Tomografia por Emissão de Pósitrons/métodos , Cateterismo Cardíaco , Angiografia Coronária , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
16.
Eur Heart J ; 38(13): 991-998, 2017 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-27141095

RESUMO

Aims: The aim of this study was to determine the diagnostic performance of single-photon emission computed tomography (SPECT), stress echocardiography (SE), invasive coronary angiography (ICA), coronary computed tomography angiography (CCTA), fractional flow reserve (FFR) derived from CCTA (FFRCT), and cardiac magnetic resonance (MRI) imaging when directly compared with an FFR reference standard. Method and results: PubMed and Web of Knowledge were searched for investigations published between 1 January 2002 and 28 February 2015. Studies performing FFR in at least 75% of coronary vessels for the diagnosis of ischaemic coronary artery disease (CAD) were included. Twenty-three articles reporting on 3788 patients and 5323 vessels were identified. Meta-analysis was performed for pooled sensitivity, specificity, likelihood ratios (LR), diagnostic odds ratio, and summary receiver operating characteristic curves. In contrast to ICA, CCTA, and FFRCT reports, studies evaluating SPECT, SE, and MRI were largely retrospective, single-centre and with generally smaller study samples. On a per-patient basis, the sensitivity of CCTA (90%, 95% CI: 86-93), FFRCT (90%, 95% CI: 85-93), and MRI (90%, 95% CI: 75-97) were higher than for SPECT (70%, 95% CI: 59-80), SE (77%, 95% CI: 61-88), and ICA (69%, 95% CI: 65-75). The highest and lowest per-patient specificity was observed for MRI (94%, 95% CI: 79-99) and for CCTA (39%, 95% CI: 34-44), respectively. Similar specificities were noted for SPECT (78%, 95% CI: 68-87), SE (75%, 95% CI: 63-85), FFRCT (71%, 95% CI: 65-75%), and ICA (67%, 95% CI: 63-71). On a per-vessel basis, the highest sensitivity was for CCTA (pooled sensitivity, 91%: 88-93), MRI (91%: 84-95), and FFRCT (83%, 78-87), with lower sensitivities for ICA (71%, 69-74), and SPECT (57%: 49-64). Per-vessel specificity was highest for MRI (85%, 79-89), FFRCT (78%: 78-81), and SPECT (75%: 69-80), whereas ICA (66%: 64-68) and CCTA (58%: 55-61) yielded a lower specificity. Conclusions: In this meta-analysis comparing cardiac imaging methods directly to FFR, MRI had the highest performance for diagnosis of ischaemia-causing CAD, with lower performance for SPECT and SE. Anatomic methods of CCTA and ICA yielded lower specificity, with functional assessment of coronary atherosclerosis by SE, SPECT, and FFRCT improving accuracy.


Assuntos
Técnicas de Imagem Cardíaca/normas , Isquemia Miocárdica/diagnóstico , Técnicas de Imagem Cardíaca/métodos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/etiologia , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Variações Dependentes do Observador , Padrões de Referência , Sensibilidade e Especificidade
17.
J Nucl Cardiol ; 24(2): 657-667, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-26843199

RESUMO

BACKGROUND: Early recognition of viable myocardium after acute myocardial infarction (AMI) is of clinical relevance, since affected segments have the potential of functional recovery. Delayed contrast-enhanced magnetic resonance imaging (DCE-CMR) has been validated extensively for the detection of viable myocardium. An alternative parameter for detecting viability is the perfusable tissue index (PTI), derived using [15O]H2O positron emission tomography (PET), which is inversely related to the extent of myocardial scar (non-perfusable tissue). The aim of the present study was to investigate the predictive value of PTI on recovery of LV function as compared to DCE-CMR in patients with AMI, after successful percutaneous coronary intervention (PCI). METHODS: Thirty-eight patients with ST elevation myocardial infarction (STEMI) successfully treated by PCI were prospectively recruited. Subjects were examined 1 week and 3 months (mean follow-up time: 97 ± 10 days) after AMI using [15O]H2O PET and DCE-CMR to assess PTI, regional function and scar. Viability was defined as recovery of systolic wall thickening ≥3.0 mm at follow-up by use of CMR. A total of 588 segments were available for serial analysis. RESULTS: At baseline, 180 segments were dysfunctional and exhibited DCE. Seventy-three (41%) of these dysfunctional segments showed full recovery during follow-up (viable), whereas 107 (59%) segments remained dysfunctional (nonviable). Baseline PTI of viable segments was 0.94 ± 0.09 and was significantly higher compared to nonviable segments (0.80 ± 0.13, P < .001). The optimal cut-off value for PTI was ≥0.85 with a sensitivity of 85% and specificity of 72%, and an area under the curve (AUC) of 0.82. In comparison, a cut-off value of <32% for the extent of DCE resulted in a sensitivity of 72% and a specificity of 69%, and an AUC of 0.75 (AUC PTI vs DCE P = .14). CONCLUSION: Assessment of myocardial viability shortly after reperfused AMI is feasible using PET. PET-derived PTI yields a good predictive value for the recovery of LV function in PCI-treated STEMI patients, in excellent agreement with DCE-CMR.


Assuntos
Imagem Cinética por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Miocárdio Atordoado/diagnóstico por imagem , Miocárdio Atordoado/etiologia , Tomografia por Emissão de Pósitrons/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Meios de Contraste , Diagnóstico Precoce , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Oxigênio , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Água
18.
Eur Heart J ; 37(26): 2069-80, 2016 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-26612582

RESUMO

BACKGROUND: Our understanding of human coronary physiological behaviour is derived from animal models. We sought to describe physiological behaviour across a large collection of invasive pressure and flow velocity measurements, to provide a better understanding of the relationships between these physiological parameters and to evaluate the rationale for resting stenosis assessment. METHODS AND RESULTS: Five hundred and sixty-seven simultaneous intracoronary pressure and flow velocity assessments from 301 patients were analysed for coronary flow velocity, trans-stenotic pressure gradient (TG), and microvascular resistance (MVR). Measurements were made during baseline and hyperaemic conditions. The whole cardiac cycle and the diastolic wave-free period were assessed. Stenoses were assessed according to fractional flow reserve (FFR) and quantitative coronary angiography DS%. With progressive worsening of stenoses, from unobstructed angiographic normal vessels to those with FFR ≤ 0.50, hyperaemic flow falls significantly from 45 to 19 cm/s, Ptrend < 0.001 in a curvilinear pattern. Resting flow was unaffected by stenosis severity and was consistent across all strata of stenosis (Ptrend > 0.05 for all). Trans-stenotic pressure gradient rose with stenosis severity for both rest and hyperaemic measures (Ptrend < 0.001 for both). Microvascular resistance declines with stenosis severity under resting conditions (Ptrend < 0.001), but was unchanged at hyperaemia (2.3 ± 1.1 mmHg/cm/s; Ptrend = 0.19). CONCLUSIONS: With progressive stenosis severity, TG rises. However, while hyperaemic flow falls significantly, resting coronary flow is maintained by compensatory reduction of MVR, demonstrating coronary auto-regulation. These data support the translation of coronary physiological concepts derived from animals to patients with coronary artery disease and furthermore, suggest that resting pressure indices can be used to detect the haemodynamic significance of coronary artery stenoses.


Assuntos
Constrição Patológica , Velocidade do Fluxo Sanguíneo , Angiografia Coronária , Circulação Coronária , Estenose Coronária , Vasos Coronários , Reserva Fracionada de Fluxo Miocárdico , Humanos
20.
Eur Heart J ; 35(31): 2094-105, 2014 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-24780500

RESUMO

BACKGROUND: Myocardial ischaemia occurs principally in the subendocardial layer, whereas conventional myocardial perfusion imaging provides no information on the transmural myocardial blood flow (MBF) distribution. Subendocardial perfusion measurements and quantification of the transmural perfusion gradient (TPG) could be more sensitive and specific for the detection of coronary artery disease (CAD). The current study aimed to determine the impact of lesion severity as assessed by the fractional flow reserve (FFR) on subendocardial perfusion and the TPG using [(15)O]H2O positron emission tomography (PET) imaging in patients evaluated for CAD. METHODS AND RESULTS: Sixty-six patients with anginal chest pain were prospectively enrolled and underwent [(15)O]H2O myocardial perfusion PET imaging. Subsequently, invasive coronary angiography was performed and FFR obtained in all coronary arteries irrespective of the PET imaging results. Thirty (45%) patients were diagnosed with significant CAD (i.e. FFR ≤0.80), whereas on a per vessel analysis (n = 198), 53 (27%) displayed a positive FFR. Transmural hyperaemic MBF decreased significantly from 3.09 ± 1.16 to 1.67 ± 0.57 mL min(-1) g(-1) (P < 0.001) in non-ischaemic and ischaemic myocardium, respectively. The TPG decreased during hyperaemia when compared with baseline (1.20 ± 0.14 vs. 0.94 ± 0.17, P < 0.001), and was lower in arteries with a positive FFR (0.97 ± 0.16 vs. 0.88 ± 0.18, P < 0.01). A TPG threshold of 0.94 yielded an accuracy to detect CAD of 59%, which was inferior to transmural MBF with an optimal cutoff of 2.20 mL min(-1) g(-1) and an accuracy of 85% (P < 0.001). Diagnostic accuracy of subendocardial perfusion measurements was comparable with transmural MBF (83 vs. 85%, respectively, P = NS). CONCLUSION: Cardiac [(15)O]H2O PET imaging is able to distinguish subendocardial from subepicardial perfusion in the myocardium of normal dimensions. Hyperaemic TPG is significantly lower in ischaemic myocardium. This technique can potentially be employed to study subendocardial perfusion impairment in more detail. However, the diagnostic accuracy of subendocardial hyperaemic perfusion and TPG appears to be limited compared with quantitative transmural MBF, warranting further study.


Assuntos
Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Placa Aterosclerótica/fisiopatologia , Angina Pectoris/fisiopatologia , Circulação Coronária/fisiologia , Feminino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/métodos , Radioisótopos de Oxigênio , Tomografia por Emissão de Pósitrons/métodos , Estudos Prospectivos , Compostos Radiofarmacêuticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA