Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 120
Filtrar
1.
Eur Radiol ; 34(1): 214-225, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37530810

RESUMO

OBJECTIVES: To evaluate the prevalence of intra-myocardial fatty scars (IMFS) most likely indicating previous silent myocardial infarction (SMI), as detected on coronary artery calcium (CAC) computed tomography (CT) scans in diabetic patients without history of coronary heart disease (CHD). METHODS: Diabetic patients screened for silent coronary insufficiency in a tertiary-care, university hospital between Jan-2015 and Dec-2016 were categorized according to their CAC score in two groups comprising 242 patients with CACS = 0 and 145 patients with CACS ≥ 300. CAC-CT scans were retrospectively evaluated for subendorcardial and transmural IMFS of the left ventricle. Adipose remodeling, patients' characteristics, cardiovascular risk factors and metabolic profile were compared between groups. RESULTS: Eighty-three (21%) patients with IMFS were identified, 55 (37.9%) in the group CACS ≥ 300 and 28 (11.6%) in the CACS = 0 (OR = 4.67; 95% CI = 2.78-7.84; p < 0.001). Total and average surface of IMFS and their number per patient were similar in both groups (p = 0.55; p = 0.29; p = 0.61, respectively). In the group CACS ≥ 300, patients with IMFS were older (p = 0.03) and had longer-lasting diabetes (p = 0.04). Patients with IMFS were older and had longer history of diabetes, reduced glomerular filtration rate, more coronary calcifications (all p < 0.05), and higher prevalence of carotid plaques (OR = 3.03; 95% CI = 1.43-6.39, p = 0.004). After correction for other variables, only a CACS ≥ 300 (OR = 5.12; 95% CI = 2.66-9.85; p < 0.001) was associated with an increased risk of having IMFS. CONCLUSIONS: In diabetic patients without known CHD, IMFSs were found in patients without coronary calcifications, although not as frequently as in patients with heavily calcified coronary arteries. It remains to be established if this marker translates in an upwards cardiovascular risk restratification especially in diabetic patients with CACS = 0. CLINICAL RELEVANCE STATEMENT: In diabetic patients without history of coronary heart disease, intramyocardial fatty scars, presumably of post-infarction origin, can be detected on coronary artery calcium CT scans more frequently, but not exclusively, if the coronary arteries are heavily calcified as compared to those without calcifications. KEY POINTS: • Intramyocardial fatty scars (IMFS), presumably of post-infarction origin, can be detected on coronary artery calcium (CAC) CT scans more frequently, but not exclusively, in diabetic patients with CACS ≥ 300 as compared to patients CACS = 0. • Patients with IMFS were older and had longer history of diabetes, reduced glomerular filtration rate, and more coronary calcifications. • Carotid plaques and CACS ≥ 300 were associated with an increased risk of having IMFS, about three and five folds respectively.


Assuntos
Calcinose , Doença da Artéria Coronariana , Diabetes Mellitus , Infarto do Miocárdio , Calcificação Vascular , Humanos , Cálcio/metabolismo , Angiografia Coronária/métodos , Estudos Retrospectivos , Cicatriz , Fatores de Risco , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico por imagem , Diabetes Mellitus/epidemiologia , Calcinose/complicações , Calcinose/diagnóstico por imagem , Calcinose/epidemiologia , Valor Preditivo dos Testes
2.
Radiology ; 309(1): e222432, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37787672

RESUMO

CT systems equipped with photon-counting detectors (PCDs), referred to as photon-counting CT (PCCT), are beginning to change imaging in several subspecialties, such as cardiac, vascular, thoracic, and musculoskeletal radiology. Evidence has been building in the literature underpinning the many advantages of PCCT for different clinical applications. These benefits derive from the distinct features of PCDs, which are made of semiconductor materials capable of converting photons directly into electric signal. PCCT advancements include, among the most important, improved spatial resolution, noise reduction, and spectral properties. PCCT spatial resolution on the order of 0.25 mm allows for the improved visualization of small structures (eg, small vessels, arterial walls, distal bronchi, and bone trabeculations) and their pathologies, as well as the identification of previously undetectable anomalies. In addition, blooming artifacts from calcifications, stents, and other dense structures are reduced. The benefits of the spectral capabilities of PCCT are broad and include reducing radiation and contrast material dose for patients. In addition, multiple types of information can be extracted from a single data set (ie, multiparametric imaging), including quantitative data often regarded as surrogates of functional information (eg, lung perfusion). PCCT also allows for a novel type of CT imaging, K-edge imaging. This technique, combined with new contrast materials specifically designed for this modality, opens the door to new applications for imaging in the future.


Assuntos
Artérias , Tomografia Computadorizada por Raios X , Humanos , Artefatos , Brônquios , Meios de Contraste
3.
Eur Radiol ; 33(8): 5476-5488, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36920517

RESUMO

OBJECTIVES: To evaluate the quality of virtual monochromatic images (VMIs) from spectral photon-counting CT (SPCCT) and two energy-integrating detector dual-energy CT (EID-DECT) scanners from the same manufacturer, for the coronary lumen. METHODS: A 21-cm section of the Mercury v4.0 phantom was scanned using a cardiac CT protocol. VMIs from 40 to 90 keV were reconstructed using high-resolution (HR) parameters for EID-DECT and SPCCT (CB and HRB kernels at 0.67 mm slice thickness, respectively). Ultra-high-resolution (UHR) parameters were used in addition to SPCCT (detailed-2 kernel, 0.43 mm slice thickness). Noise-power-spectrum (NPS), task-based transfer function (TTF), and detectability index (d') were computed for 2-mm-diameter lumen detection. In consensus, two radiologists analyzed the quality of the images from 8 patients who underwent coronary CTA on both CT systems. RESULTS: For all keV images, fpeak, f50, and d' were higher with SPCCT. The fpeak and f50 were higher with UHR-SPCCT with greater noise and lower d' compared to those of the HR-SPCCT images. Noise magnitude was constant for all energy levels (keV) with both systems, and lower with HR images, and d' decreased as keV decreased. Subjective analysis showed greater lumen sharpness and overall quality for HR and UHR-SPCCT images using all keV, with a greater difference at low keV compared to HR-EID-DECT images. CONCLUSION: HR and UHR-SPCCT images gave greater detectability of the coronary lumen for 40 to 90 keV VMIs compared to two EID-DECT systems, with benefits of higher lumen sharpness and overall quality. KEY POINTS: • Compared with 2 dual-energy CT systems, spectral photon-counting CT (SPCCT) improved spatial resolution, noise texture, noise magnitude, and detectability of the coronary lumen. • Use of ultra-high-resolution parameters with SPCCT improved spatial resolution and noise texture and provided high detectability of the coronary lumen, despite an increase in noise magnitude. • In eight patients, radiologists found greater overall image quality with SPCCT for all virtual monochromatic images with a greater difference at low keV, compared with dual-energy CT systems.


Assuntos
Vasos Coronários , Tomografia Computadorizada por Raios X , Humanos , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Coração , Fótons
4.
Radiology ; 303(2): 303-313, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35166583

RESUMO

Background Spatial resolution, soft-tissue contrast, and dose-efficient capabilities of photon-counting CT (PCCT) potentially allow a better quality and diagnostic confidence of coronary CT angiography (CCTA) in comparison to conventional CT. Purpose To compare the quality of CCTA scans obtained with a clinical prototype PCCT system and an energy-integrating detector (EID) dual-layer CT (DLCT) system. Materials and Methods In this prospective board-approved study with informed consent, participants with coronary artery disease underwent retrospective electrocardiographically gated CCTA with both systems after injection of 65-75 mL of 400 mg/mL iodinated contrast agent at 5 mL/sec. A prior phantom task-based quality assessment of the detectability index of coronary lesions was performed. Ultra-high-resolution parameters were used for PCCT (1024 matrix, 0.25-mm section thickness) and EID DLCT (512 matrix, 0.67-mm section thickness). Three cardiac radiologists independently performed a blinded analysis using a five-point quality score (1 = insufficient, 5 = excellent) for overall image quality, diagnostic confidence, and diagnostic quality of calcifications, stents, and noncalcified plaques. A logistic regression model, adjusted for radiologists, was used to evaluate the proportion of improvement in scores with the best method. Results Fourteen consecutive participants (12 men; mean age, 61 years ± 17) were enrolled. Scores of overall quality and diagnostic confidence were higher with PCCT images with a median of 5 (interquartile range [IQR], 2) and 5 (IQR, 1) versus 4 (IQR, 1) and 4 (IQR, 3) with EID DLCT images, using a mean tube current of 255 mAs ± 0 versus 349 mAs ± 111 for EID DLCT images (P < .01). Proportions of improvement with PCCT images for quality of calcification, stent, and noncalcified plaque were 100%, 92% (95% CI: 71, 98), and 45% (95% CI: 28, 63), respectively. In the phantom study, detectability indexes were 2.3-fold higher for lumen and 2.9-fold higher for noncalcified plaques with PCCT images. Conclusion Coronary CT angiography with a photon-counting CT system demonstrated in humans an improved image quality and diagnostic confidence compared with an energy-integrating dual-layer CT. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Sandfort and Bluemke in this issue.


Assuntos
Angiografia por Tomografia Computadorizada , Fótons , Angiografia por Tomografia Computadorizada/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
5.
Eur Radiol ; 32(1): 524-532, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34185147

RESUMO

OBJECTIVES: To evaluate the image quality (IQ) of a spectral photon-counting CT (SPCCT) using filtered back projection (FBP) and hybrid iterative reconstruction (IR) algorithms (iDose4), in comparison with a dual-layer CT (DLCT) system, and to choose the best image quality according to the IR level for SPCCT. METHODS: Two phantoms were scanned using a standard lung protocol (120 kVp, 40 mAs) with SPCCT and DLCT systems. Raw data were reconstructed using FBP and 9 iDose4 levels (i1/i2/i3/i4/i5/i6/i7/i9/i11) for SPCCT and 7 for DLCT (i1/i2/i3/i4/i5/i6/i7). Noise power spectrum and task-based transfer function (TTF) were computed. Detectability index (d') was computed for detection of 4 mm ground-glass nodule (GGN) and solid nodule. Two chest radiologists performed an IQ evaluation (noise/nodule sharpness/nodule conspicuity/overall IQ) in consensus, and chose the best image for SPCCT. RESULTS: Noise magnitude was -47% ± 2% lower on average with SPCCT than with DLCT for iDose4 range from i1 to i6. Average NPS spatial frequencies increased for SPCCT in comparison with DLCT. TTF also increased, except for the air insert with FBP, and i1/i2/i3. Higher detectability was found for SPCCT for both GGN and solid nodules. IQ for both types of nodule was rated consistently higher with SPCCT than with DLCT for the same iDose4 level. For SPCCT and both nodules, the scores for noise and conspicuity improved with increasing iDose4 level. iDose4 level 6 provided the best subjective IQ for both types of nodule. CONCLUSIONS: Higher IQ for GGN and solid nodules was demonstrated with SPCCT compared with DLCT with better detectability using iDose4. KEY POINTS: Using spectral photon-counting CT compared with dual-layer CT, noise magnitude was reduced with improvements in spatial resolution and detectability of ground-glass nodules and solid lung nodules. As the iDose4 level increased, noise magnitude was reduced and detectability of ground-glass and solid lung nodules was better for both CT systems. For spectral photon-counting CT imaging, two chest radiologists determined iDose4 level 6 as the best image quality for detecting ground-glass nodules and solid lung nodules.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Algoritmos , Humanos , Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação
6.
J Nucl Cardiol ; 29(3): 1064-1074, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33145738

RESUMO

BACKGROUND: Previous studies have suggested the role of microcalcifications in plaque vulnerability. This exploratory study sought to assess the potential of hybrid positron-emission tomography (PET)/magnetic resonance imaging (MRI) using 18F-sodium fluoride (18F-NaF) to check simultaneously 18F-NaF uptake, a marker of microcalcifications, and morphological criteria of vulnerability. METHODS AND RESULTS: We included 12 patients with either recently symptomatic or asymptomatic carotid stenosis. All patients underwent 18F-NaF PET/MRI. 18F-NaF target-to-background ratio (TBR) was measured in culprit and nonculprit (including contralateral plaques of symptomatic patients) plaques as well as in other arterial walls. Morphological criteria of vulnerability were assessed on MRI. Mineral metabolism markers were also collected. 18F-NaF uptake was higher in culprit compared to nonculprit plaques (median TBR 2.6 [2.2-2.8] vs 1.7 [1.3-2.2]; P = 0.03) but was not associated with morphological criteria of vulnerability on MRI. We found a positive correlation between 18F-NaF uptake and calcium plaque volume and ratio but not with circulating tissue-nonspecific alkaline phosphatase (TNAP) activity and inorganic pyrophosphate (PPi) levels. 18F-NaF uptake in the other arterial walls did not differ between symptomatic and asymptomatic patients. CONCLUSIONS: 18F-NaF PET/MRI may be a promising tool for providing additional insights into the plaque vulnerability.


Assuntos
Calcinose , Estenose das Carótidas , Placa Aterosclerótica , Calcinose/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Placa Aterosclerótica/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Fluoreto de Sódio
7.
Radiology ; 300(1): 98-107, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33944628

RESUMO

Background Macrophage burden is a major factor in the risk of atherosclerotic plaque rupture, and its evaluation remains challenging with molecular noninvasive imaging approaches. Photon-counting CT (PCCT) with k-edge imaging aims to allow for the specific detection of macrophages using gold nanoparticles. Purpose To perform k-edge imaging in combination with gold nanoparticles to detect and quantify the macrophage burden within the atherosclerotic aortas of rabbits. Materials and Methods Atherosclerotic and control New Zealand white rabbits were imaged before and at several time points up to 2 days after intravenous injection of gold nanoparticles (3.5 mL/kg, 65 mg gold per milliliter). Aortic CT angiography was performed at the end of the follow-up using an intravenous injection of an iodinated contrast material. Gold k-edge and conventional CT images were reconstructed for qualitative and quantitative assessment of the macrophage burden. PCCT imaging results were compared with findings at histologic examination, quantitative histomorphometry, transmission electron microscopy, and quantitative inductively coupled plasma optical emission spectrometry. Pearson correlations between the macrophage area measured in immunostained sections and the concentration of gold and attenuation measured in the corresponding PCCT sections were calculated. Results Seven rabbits with atherosclerosis and four control rabbits without atherosclerosis were analyzed. In atherosclerotic rabbits, calcifications were observed along the aortic wall before injection. At 2 days after injection of gold nanoparticles, only gold k-edge images allowed for the distinction of plaque enhancement within calcifications and for lumen enhancement during angiography. A good correlation was observed between the gold concentration measured within the wall and the macrophage area in 35 plaques (five per rabbit) (r = 0.82; 95% CI: 0.67, 0.91; P < .001), which was higher than that observed on conventional CT images (r = 0.41; 95% CI: 0.09, 0.65; P = .01). Transmission electron microscopy and inductively coupled plasma optical emission spectrometry analyses confirmed the gold k-edge imaging findings. Conclusion Photon-counting CT with gold nanoparticles allowed for the noninvasive evaluation of both molecular and anatomic information in vivo in rabbits with atherosclerotic plaques. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Leiner in this issue.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Placa Aterosclerótica/diagnóstico por imagem , Animais , Aorta/diagnóstico por imagem , Modelos Animais de Doenças , Ouro , Macrófagos , Nanopartículas Metálicas , Fótons , Coelhos
8.
Eur Radiol ; 31(9): 7132-7142, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33740093

RESUMO

OBJECTIVES: To quantitatively evaluate the impact of virtual monochromatic images (VMI) on reduced-iodine-dose dual-energy coronary computed tomography angiography (CCTA) in terms of coronary lumen segmentation in vitro, and secondly to assess the image quality in vivo, compared with conventional CT obtained with regular iodine dose. MATERIALS AND METHODS: A phantom simulating regular and reduced iodine injection was used to determine the accuracy and precision of lumen area segmentation for various VMI energy levels. We retrospectively included 203 patients from December 2017 to August 2018 (mean age, 51.7 ± 16.8 years) who underwent CCTA using either standard (group A, n = 103) or reduced (group B, n = 100) iodine doses. Conventional images (group A) were qualitatively and quantitatively compared with 55-keV VMI (group B). We recorded the location of venous catheters. RESULTS: In vitro, VMI outperformed conventional CT, with a segmentation accuracy of 0.998 vs. 1.684 mm2, respectively (p < 0.001), and a precision of 0.982 vs. 1.229 mm2, respectively (p < 0.001), in simulated overweight adult subjects. In vivo, the rate of diagnostic CCTA in groups A and B was 88.4% (n = 91/103) vs. 89% (n = 89/100), respectively, and noninferiority of protocol B was inferred. Contrast-to-noise ratios (CNR) of lumen versus fat and muscle were higher in group B (p < 0.001) and comparable for lumen versus calcium (p = 0.423). Venous catheters were more often placed on the forearm or hand in group B (p < 0.001). CONCLUSION: In vitro, low-keV VMI improve vessel area segmentation. In vivo, low-keV VMI allows for a 40% iodine dose and injection rate reduction while maintaining diagnostic image quality and improves the CNR between lumen versus fat and muscle. KEY POINTS: • Dual-energy coronary CT angiography is becoming increasingly available and might help improve patient management. • Compared with regular-iodine-dose coronary CT angiography, reduced-iodine-dose dual-energy CT with low-keV monochromatic image reconstructions performed better in phantom-based vessel cross-sectional segmentation and proved to be noninferior in vivo. • Patients receiving reduced-iodine-dose dual-energy coronary CT angiography often had the venous catheter placed on the forearm or wrist without compromising image quality.


Assuntos
Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Adulto , Idoso , Angiografia por Tomografia Computadorizada , Meios de Contraste , Relação Dose-Resposta a Droga , Humanos , Iodo/administração & dosagem , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
9.
Eur Radiol ; 31(2): 795-803, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32813105

RESUMO

OBJECTIVES: To assess the diagnostic performances of chest CT for triage of patients in multiple emergency departments during COVID-19 epidemic, in comparison with reverse transcription polymerase chain reaction (RT-PCR) test. METHOD: From March 3 to April 4, 2020, 694 consecutive patients from three emergency departments of a large university hospital, for which a hospitalization was planned whatever the reasons, i.e., COVID- or non-COVID-related, underwent a chest CT and one or several RT-PCR tests. Chest CTs were rated as "Surely COVID+," "Possible COVID+," or "COVID-" by experienced radiologists. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated using the final RT-PCR test as standard of reference. The delays for CT reports and RT-PCR results were recorded and compared. RESULTS: Among the 694 patients, 287 were positive on the final RT-PCR exam. Concerning the 694 chest CT, 308 were rated as "Surely COVID+", 34 as "Possible COVID+," and 352 as "COVID-." When considering only the "Surely COVID+" CT as positive, accuracy, sensitivity, specificity, PPV, and NPV reached 88.9%, 90.2%, 88%, 84.1%, and 92.7%, respectively, with respect to final RT-PCR test. The mean delay for CT reports was three times shorter than for RT-PCR results (187 ± 148 min versus 573 ± 327 min, p < 0.0001). CONCLUSION: During COVID-19 epidemic phase, chest CT is a rapid and most probably an adequately reliable tool to refer patients requiring hospitalization to the COVID+ or COVID- hospital units, when response times for virological tests are too long. KEY POINTS: • In a large university hospital in Lyon, France, the accuracy, sensitivity, specificity, PPV, and NPV of chest CT for COVID-19 reached 88.9%, 90.2%, 88%, 84.1%, and 92.7%, respectively, using RT-PCR as standard of reference. • The mean delay for CT reports was three times shorter than for RT-PCR results (187 ± 148 min versus 573 ± 327 min, p < 0.0001). • Due to high accuracy of chest CT for COVID-19 and shorter time for CT reports than RT-PCR results, chest CT can be used to orient patients suspected to be positive towards the COVID+ unit to decrease congestion in the emergency departments.


Assuntos
COVID-19/diagnóstico por imagem , Triagem , Idoso , Idoso de 80 Anos ou mais , COVID-19/epidemiologia , Serviço Hospitalar de Emergência , Epidemias , Feminino , França , Hospitais Universitários , Humanos , Masculino , Valor Preditivo dos Testes , SARS-CoV-2 , Fatores de Tempo , Tomografia Computadorizada por Raios X
10.
Eur Radiol ; 30(1): 425-431, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31332557

RESUMO

OBJECTIVES: To assess the capability of a newly developed material decomposition method from contrast-enhanced dual-energy CT images, aiming to better visualize the aortic wall and aortic intramural hematoma (IMH), compared with true non-contrast (TNC) CT. MATERIALS AND METHODS: Twenty-two patients (11 women; mean age, 61 ± 20 years) with acute chest pain underwent 25 dual-layer non-contrast and contrast-enhanced CT. CT-angiography images were retrospectively processed using two-material decomposition analysis, where we defined the first material as the content of a region of interest placed in the ascending aorta for each patient, and the second material as water. Two independent radiologists assessed the images from the second material termed "dark-blood" images and the TNC images regarding contrast-to-noise ratio (CNR) between the wall and the lumen, diagnostic quality regarding the presence of aortic wall thickening, and the inner/outer vessel wall conspicuity. RESULTS: Diagnostic quality scores in normal aortic segments were 0.9 ± 0.3 and 2.7 ± 0.6 (p < 0.001) and wall conspicuity scores were 0.7 ± 0.5 and 1.8 ± 0.3 (p < 0.001) on TNC and dark-blood images, respectively. In aortic segments with IMH, diagnostic quality scores were 1.7 ± 0.5 and 2.4 ± 0.6 (p < 0.001) and wall conspicuity scores were 0.7 ± 0.7 and 1.8 ± 0.3 (p < 0.001) on TNC and dark-blood images, respectively. In normal aortic segments, CNRs were 0.3 ± 0.2 and 2.8 ± 0.9 on TNC and dark-blood images, respectively (p < 0.001). In aortic segments with IMH, CNRs were 0.3 ± 0.2 and 4.0 ± 1.0 on TNC and dark-blood images, respectively (p < 0.001). CONCLUSIONS: Compared with true non-contrast CT, dark-blood material decomposition maps enhance quantitative and qualitative image quality for the assessment of normal aortic wall and IMH. KEY POINTS: • Current dual-energy CT-angiography provides virtual non-contrast and bright-blood images. • Dark-blood images represent a new way to assess the vascular wall structure with dual-energy CT and can improve the lumen-to-wall contrast compared with true non-contrast CT. • This dual-energy CT material decomposition method is likely to improve contrast resolution in other applications as well, taking advantage of the high spatial resolution of CT.


Assuntos
Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Hematoma/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
12.
Eur Radiol ; 29(12): 6762-6771, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31264015

RESUMO

PURPOSE: To assess whether virtual non-contrast (VNC) images derived from contrast dual-layer dual-energy computed tomography (DL-DECT) images could replace true non-contrast (TNC) images for aortic intramural hematoma (IMH) diagnosis in acute aortic syndrome (AAS) imaging protocols by performing quantitative as well as qualitative phantom and clinical studies. MATERIALS AND METHODS: Patients with confirmed IMH were included retrospectively in two centers. For in vitro imaging, a custom-made phantom of IMH was placed in a semi-anthropomorphic thorax phantom (QRM GmbH) and imaged on a DL-DECT at 120 kVp under various conditions of patient size, radiation exposure, and reconstruction modes. For in vivo imaging, 21 patients (70 ± 13 years) who underwent AAS imaging protocols at 120 kVp were included. In both studies, contrast-to-noise ratio (CNR) between hematoma and lumen was compared using a paired t test. Diagnostic confidence (1 = non-diagnostic, 4 = exemplary) for VNC and TNC images was rated by two radiologists and compared. Effective radiation doses for each acquisition were calculated. RESULTS: In both the phantom and clinical studies, we observed that the CNRs were similar between the VNC and TNC images. Moreover, both methods allowed differentiating the hyper-attenuation within the hematoma from the blood. Finally, we obtained equivalent high diagnostic confidence with both VNC and TNC images (VNC = 3.2 ± 0.7, TNC = 3.1 ± 0.7; p = 0.3). Finally, by suppressing TNC acquisition and using VNC, the mean effective dose reduction would be 40%. CONCLUSION: DL-DECT offers similar performances with VNC and TNC images for IMH diagnosis without compromise in diagnostic image quality. KEY POINTS: • Dual-layer dual-energy CT enables virtual non-contrast imaging from a contrast-enhanced acquisition. • Virtual non-contrast imaging with dual-layer dual-energy CT reduces the number of acquisitions and radiation exposure in acute aortic syndrome imaging protocol. • Dual-layer dual-energy CT has the potential to become a suitable imaging tool for acute aortic syndrome.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Hematoma/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Feminino , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
14.
Eur Radiol ; 28(8): 3355-3361, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29468341

RESUMO

OBJECTIVES: Endovascular renal denervation (RDN) using catheter-based radiofrequency (RF) ablation has emerged as a potential treatment option for drug-resistant hypertension. Its efficacy is currently under debate. We aimed to evaluate the capability of contrast-enhanced magnetic resonance imaging (MRI) to assess the effects of RDN on the renal arterial wall in patients presenting with drug-resistant hypertension. METHODS: Patients were included prospectively following institutional review board approval and written informed consent. Renal arteries were imaged using a two-dimensional T1-weighted TSE sequence pre- and post-administration of a gadolinium-based contrast agent, before (D0), 2 days (D2) and 6 months (M6) after RDN. Mean enhancement of the wall (mENH) and mean wall thickness (mWT) were compared across time using an ANOVA with repeated measures and post-hoc paired t-test. RESULTS: Follow-up was completed for 23 patients (median age, 57 years; 16 men). The mENH at D2 (96.3 ± 36.0 %) was significantly higher than at D0 (61.1 ± 26.3%, p < 0.001) and M6 (66.1±22.7%, p < 0.001). Similarly, mWT was significantly higher at D2 (3.1 ± 0.4 m) than at D0 (2.7 ± 0.4mm, p < 0.001) and M6 (2.9 ± 0. 5 mm, p = 0.002). CONCLUSIONS: MRI demonstrated abnormalities of the arterial wall 2 days after RDN that had resolved at 6 months. KEY POINTS: • Contrast-enhanced MRI provides anatomic evidence of renal artery RF ablation • Temperature increase related to RF ablation induces transient arterial wall inflammation • Morphological effects observed 2 days post RF ablation are not visible after 6 months.


Assuntos
Ablação por Cateter/efeitos adversos , Hipertensão/cirurgia , Complicações Intraoperatórias/diagnóstico , Artéria Renal/lesões , Simpatectomia/efeitos adversos , Idoso , Análise de Variância , Anti-Hipertensivos/uso terapêutico , Ablação por Cateter/métodos , Resistência a Medicamentos , Feminino , Humanos , Hipertensão/tratamento farmacológico , Hipertensão/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Simpatectomia/métodos
15.
Eur Radiol ; 28(8): 3318-3325, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29460069

RESUMO

OBJECTIVES: After endovascular aortic repair (EVAR), discrimination of endoleaks and intra-aneurysmatic calcifications within the aneurysm often requires multiphase computed tomography (CT). Spectral photon-counting CT (SPCCT) in combination with a two-contrast agent injection protocol may provide reliable detection of endoleaks with a single CT acquisition. METHODS: To evaluate the feasibility of SPCCT, the stent-lined compartment of an abdominal aortic aneurysm phantom was filled with a mixture of iodine and gadolinium mimicking enhanced blood. To represent endoleaks of different flow rates, the adjacent compartments contained either one of the contrast agents or calcium chloride to mimic intra-aneurysmatic calcifications. After data acquisition with a SPCCT prototype scanner with multi-energy bins, material decomposition was performed to generate iodine, gadolinium and calcium maps. RESULTS: In a conventional CT slice, Hounsfield units (HU) of the compartments were similar ranging from 147 to 168 HU. Material-specific maps differentiate the distributions within the compartments filled with iodine, gadolinium or calcium. CONCLUSION: SPCCT may replace multiphase CT to detect endoleaks without sacrificing diagnostic accuracy. It is a unique feature of our method to capture endoleak dynamics and allow reliable distinction from intra-aneurysmatic calcifications in a single scan, thereby enabling a significant reduction of radiation exposure. KEY POINTS: • SPCCT might enable advanced endoleak detection. • Material maps derived from SPCCT can differentiate iodine, gadolinium and calcium. • SPCCT may potentially reduce radiation burden for EVAR patients under post-interventional surveillance.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Meios de Contraste , Endoleak/diagnóstico por imagem , Procedimentos Endovasculares/métodos , Fótons , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Gadolínio , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Stents
16.
Radiology ; 283(3): 723-728, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27918709

RESUMO

Purpose To investigate the feasibility of using spectral photon-counting computed tomography (CT) to differentiate between gadolinium-based and nonionic iodine-based contrast material in a colon phantom by using the characteristic k edge of gadolinium. Materials and Methods A custom-made colon phantom was filled with nonionic iodine-based contrast material, and a gadolinium-filled capsule representing a contrast material-enhanced polyp was positioned on the colon wall. The colon phantom was scanned with a preclinical spectral photon-counting CT system to obtain spectral and conventional data. By fully using the multibin spectral information, material decomposition was performed to generate iodine and gadolinium maps. Quantitative measurements were performed within the lumen and polyp to quantitatively determine the absolute content of iodine and gadolinium. Results In a conventional CT section, absorption values of both contrast agents were similar at approximately 110 HU. Contrast material maps clearly differentiated the distributions, with gadolinium solely in the polyp and iodine in the lumen of the colon. Quantitative measurements of contrast material concentrations in the colon and polyp matched well with those of actual prepared mixtures. Conclusion Dual-contrast spectral photon-counting CT colonography with iodine-filled lumen and gadolinium-tagged polyps may enable ready differentiation between polyps and tagged fecal material. © RSNA, 2016.


Assuntos
Colonografia Tomográfica Computadorizada , Colonografia Tomográfica Computadorizada/métodos , Meios de Contraste , Gadolínio , Compostos de Iodo , Imagens de Fantasmas , Fótons
17.
Eur Radiol ; 26(8): 2723-9, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26560716

RESUMO

OBJECTIVE: To evaluate the value of the diameter of the draining vein of pulmonary arteriovenous malformation (PAVM) on unenhanced chest MDCT in diagnosing reperfusion after percutaneous vaso-occlusion therapy. METHODS: We retrospectively reviewed our long-term experience of patients with hereditary haemorrhagic telangiectasia and selected cases on the following criteria: an initial pulmonary angiogram with embolotherapy of at least one PAVM, a follow-up MDCT examination in the following year followed by a second pulmonary angiogram with embolotherapy if needed. Follow-up unenhanced chest MDCT examinations were analyzed blindly from results of pulmonary artery angiogram and clinical data, the diameter of the efferent vein close to the PAVM sac was measured, then compared to those of pulmonary artery angiogram as a gold standard. RESULTS: Eighty-eight of 100 patients met inclusion criteria, in whom 62 of 176 PAVMs were reperfused at angiogram. The mean diameter of the efferent vein on MDCT was 4.3 ± 2.1 mm in patent PAVMs and 1.8 ± 0.9 mm in non-patent PAVMs (p < 0.0001). The optimal cutoff diameter based on ROC analysis was 2.5 mm (sensitivity = 98.4 %; specificity = 87.7 %). CONCLUSION: A diameter of the draining vein of PAVM of 2.5 mm or greater on unenhanced MDCT is a strong predictor of reperfusion. KEY POINTS: • Diameter of draining vein of 2.5 mm or greater is associated with reperfusion. • Unenhanced chest MDCT predicts reperfusion of PAVMs with good sensitivity and specificity. • Unenhanced MDCT can guide a decision of repeat pulmonary angiogram and embolotherapy. • The mean vein diameter change of PAVMs occluded at follow-up is 3.8 mm. • Overall success rate after a median of 6 months embolotherapy was 64.7 %.


Assuntos
Angiografia/métodos , Malformações Arteriovenosas/diagnóstico , Embolização Terapêutica/métodos , Tomografia Computadorizada Multidetectores/métodos , Artéria Pulmonar/anormalidades , Embolia Pulmonar/diagnóstico , Veias Pulmonares/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Malformações Arteriovenosas/complicações , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/etiologia , Embolia Pulmonar/terapia , Veias Pulmonares/anormalidades , Estudos Retrospectivos , Adulto Jovem
19.
J Xray Sci Technol ; 22(2): 253-70, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24699351

RESUMO

BACKGROUND: 4D cardiac computed tomography aims at reconstructing the beating heart from a series of 2D projections and the simultaneously acquired electrocardiogram. Each cardiac phase is reconstructed by exploiting the subset of projections acquired during this particular cardiac phase only. In these conditions, the Feldkamp, Davis and Kress method (FDK) generates large streak artifacts in the reconstructed volumes, hampering the medical interpretation. These artifacts can be substantially reduced by deconvolution methods. OBJECTIVE: The aim of this paper is to compare two 4D cardiac CT reconstruction methods based on deconvolution, and to evaluate their practical benefits on two applications: cardiac micro CT and human cardiac C-arm CT. METHODS: The first evaluated method builds upon inverse filtering. It has been proposed recently and demonstrated on 4D cardiac micro CT. The second one is an iterative deconvolution method, and turns out equivalent to an ECG-gated Iterative Filtered Back Projection (ECG-gated IFBP). RESULTS: Results are presented on simulated data in 2D parallel beam, 2D fan beam and 3D cone beam geometries. CONCLUSIONS: Both methods are efficient on the cardiac micro CT simulations, but insufficient to handle 4D human cardiac C-Arm CT simulations. Overall, ECG-gated IFPB largely outperforms the inverse filtering method.


Assuntos
Artefatos , Eletrocardiografia/métodos , Tomografia Computadorizada Quadridimensional/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Simulação por Computador , Humanos , Imagens de Fantasmas
20.
bioRxiv ; 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38464166

RESUMO

3D printed biomaterial implants are revolutionizing personalized medicine for tissue repair, especially in orthopedics. In this study, a radiopaque Bi 2 O 3 doped polycaprolactone ( PCL ) composite is developed and implemented to enable the use of diagnostic X-ray technologies, especially photon counting X-ray computed tomography ( PCCT ), for comprehensive in vivo device monitoring. PCL filament with homogeneous Bi 2 O 3 nanoparticle ( NP ) dispersion (0.8 to 11.7 wt%) are first fabricated. Tissue engineered scaffolds ( TES ) are then 3D printed with the composite filament, optimizing printing parameters for small feature size and severely overhung geometries. These composite TES are characterized via micro-computed tomography ( µ CT ), tensile testing, and a cytocompatibility study, with Bi 2 O 3 mass fractions as low as 2 wt% providing excellent radiographic distinguishability, improved tensile properties, and equivalent cytocompatibility of neat PCL. The excellent radiographic distinguishability is validated in situ by imaging 4 and 7 wt% TES in a mouse model with µCT, showing excellent agreement with in vitro measurements. Subsequently, CT image-derived swine menisci are 3D printed with composite filament and re-implanted in their corresponding swine legs ex vivo . Re-imaging the swine legs via clinical CT allows facile identification of device location and alignment. Finally, the emergent technology of PCCT unambiguously distinguishes implanted menisci in situ.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA