1.
Clin Chem ; 63(7): 1248-1260, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28522444

RESUMO

BACKGROUND: The IFCC Committee for Standardization of Thyroid Function Tests developed a global harmonization approach for thyroid-stimulating hormone measurements. It is based on a multiassay method comparison study with clinical serum samples and target setting with a robust factor analysis method. Here we describe the Phase IV method comparison and reference interval (RI) studies conducted with the objective to recalibrate the participating assays and demonstrate the proof-of-concept. METHODS: Fourteen manufacturers measured the harmonization and RI panel; 4 of them quantified the harmonization and first follow-up panel in parallel. All recalibrated their assays to the statistically inferred targets. For validation, we used desirable specifications from the biological variation for the bias and total error (TE). The RI measurements were done with the assays' current calibrators, but data were also reported after transformation to the new calibration status. We estimated the pre- and postrecalibration RIs with a nonparametric bootstrap procedure. RESULTS: After recalibration, 14 of 15 assays met the bias specification with 95% confidence; 8 assays complied with the TE specification. The CV of the assay means for the harmonization panel was reduced from 9.5% to 4.2%. The RI study showed improved uniformity after recalibration: the ranges (i.e., maximum differences) exhibited by the assay-specific 2.5th, 50th, and 97.5th percentile estimates were reduced from 0.27, 0.89, and 2.13 mIU/L to 0.12, 0.29, and 0.77 mIU/L. CONCLUSIONS: We showed that harmonization increased the agreement of results from the participating immunoassays, and may allow them to adopt a more uniform RI in the future.


Assuntos
Imunoensaio , Tireotropina/sangue , Calibragem , Humanos , Imunoensaio/normas , Padrões de Referência , Valores de Referência , Tireotropina/normas
2.
Clin Chem ; 63(10): 1642-1652, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28720678

RESUMO

BACKGROUND: The IFCC Committee for Standardization of Thyroid Function Tests intended to standardize free thyroxine (FT4) immunoassays. We developed a Système International d'Unités traceable conventional reference measurement procedure (RMP) based on equilibrium dialysis and mass spectrometry. We describe here the latest studies intended to recalibrate against the RMP and supply a proof of concept, which should allow continued standardization efforts. METHODS: We used the RMP to target the standardization and reference interval (RI) panels, which were also measured by 13 manufacturers. We validated the suitability of the recalibrated results to meet specifications for bias (3.3%) and total error (8.0%) determined from biological variation. However, because these specifications were stringent, we expanded them to 10% and 13%, respectively. The results for the RI panel were reported as if the assays were recalibrated. We estimated all but 1 RI using parametric statistical procedures and hypothesized that the RI determined by the RMP was suitable for use by the recalibrated assays. RESULTS: Twelve of 13 recalibrated assays had a bias, meeting the 10% specification with 95% confidence; for 7 assays, this applied even for the 3.3% specification. Only 1 assay met the 13% total error specification. Recalibration reduced the CV of the assay means for the standardization panel from 13% to 5%. The proof-of-concept study confirmed our hypothesis regarding the RI but within constraints. CONCLUSIONS: Recalibration to the RMP significantly reduced the FT4 immunoassays' bias, so that the RI determined by the RMP was suitable for common use within a margin of 12.5%.


Assuntos
Testes de Função Tireóidea/métodos , Testes de Função Tireóidea/normas , Tiroxina/sangue , Calibragem , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Humanos , Imunoensaio/métodos , Imunoensaio/normas , Limite de Detecção , Valores de Referência , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Tiroxina/análise
3.
Clin Chem ; 67(12): 1589, 2021 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-34850842
4.
Endocr J ; 62(10): 855-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26211473

RESUMO

Given the prevalence of thyroid disorders and the subtle signs and symptoms that may accompany subclinical disease, reliable laboratory testing for serum TSH and free thyroid hormones is important for both primary care physicians and endocrinologists. The laboratory community has recognized the need for standardization of thyroid function tests to achieve comparability of measurement results between methods. This applies in particular to tests for free T4 (FT4), which may be considered controversial in terms of clinical and analytical validity. However, variability is also observed with TSH testing - a fact which has not been emphasized in ongoing discussions regarding lowering the upper limit of normal and/or common decision limits to start treatment for hypothyroidism. In response to this need, the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Committee for Standardization of Thyroid Function Tests worked over the years towards the goal of standardization of FT4 and TSH testing.


Assuntos
Testes de Função Tireóidea , Tireotropina/sangue , Tiroxina/sangue , Química Clínica/métodos , Química Clínica/tendências , Endocrinologia , Humanos , Agências Internacionais , Médicos , Guias de Prática Clínica como Assunto , Reprodutibilidade dos Testes , Medição de Risco , Sociedades Científicas , Testes de Função Tireóidea/normas , Testes de Função Tireóidea/tendências , Recursos Humanos
5.
Crit Rev Clin Lab Sci ; 50(1): 23-36, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23480440

RESUMO

Sepsis is an unusual systemic reaction to what is sometimes an otherwise ordinary infection, and it probably represents a pattern of response by the immune system to injury. A hyper-inflammatory response is followed by an immunosuppressive phase during which multiple organ dysfunction is present and the patient is susceptible to nosocomial infection. Biomarkers to diagnose sepsis may allow early intervention which, although primarily supportive, can reduce the risk of death. Although lactate is currently the most commonly used biomarker to identify sepsis, other biomarkers may help to enhance lactate's effectiveness; these include markers of the hyper-inflammatory phase of sepsis, such as pro-inflammatory cytokines and chemokines; proteins such as C-reactive protein and procalcitonin which are synthesized in response to infection and inflammation; and markers of neutrophil and monocyte activation. Recently, markers of the immunosuppressive phase of sepsis, such as anti-inflammatory cytokines, and alterations of the cell surface markers of monocytes and lymphocytes have been examined. Combinations of pro- and anti-inflammatory biomarkers in a multi-marker panel may help identify patients who are developing severe sepsis before organ dysfunction has advanced too far. Combined with innovative approaches to treatment that target the immunosuppressive phase, these biomarkers may help to reduce the mortality rate associated with severe sepsis which, despite advances in supportive measures, remains high.


Assuntos
Biomarcadores/metabolismo , Sepse/metabolismo , Citocinas/metabolismo , Humanos , Terapia de Imunossupressão , Inflamação/patologia , Ativação de Neutrófilo , Sepse/diagnóstico , Sepse/imunologia , Sepse/microbiologia
6.
Arch Pathol Lab Med ; 146(5): 575-590, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-34347866

RESUMO

CONTEXT.­: The process for identifying patients with monoclonal gammopathies is complex. Initial detection of a monoclonal immunoglobulin protein (M protein) in the serum or urine often requires compilation of analytical data from several areas of the laboratory. The detection of M proteins depends on adequacy of the sample provided, available clinical information, and the laboratory tests used. OBJECTIVE.­: To develop an evidence-based guideline for the initial laboratory detection of M proteins. DESIGN.­: To develop evidence-based recommendations, the College of American Pathologists convened a panel of experts in the diagnosis and treatment of monoclonal gammopathies and the laboratory procedures used for the initial detection of M proteins. The panel conducted a systematic literature review to address key questions. Using the Grading of Recommendations Assessment, Development, and Evaluation approach, recommendations were created based on the available evidence, strength of that evidence, and key judgements as defined in the Grading of Recommendations Assessment, Development, and Evaluation Evidence to Decision framework. RESULTS.­: Nine guideline statements were established to optimize sample selection and testing for the initial detection and quantitative measurement of M proteins used to diagnose monoclonal gammopathies. CONCLUSIONS.­: This guideline was constructed to harmonize and strengthen the initial detection of an M protein in patients displaying symptoms or laboratory features of a monoclonal gammopathy. It endorses more comprehensive initial testing when there is suspicion of amyloid light chain amyloidosis or neuropathies, such as POEMS (polyneuropathy, organomegaly, endocrinopathy, M protein, and skin changes) syndrome, associated with an M protein.


Assuntos
Paraproteinemias , Humanos , Laboratórios , Paraproteinemias/diagnóstico , Revisões Sistemáticas como Assunto
11.
mSphere ; 6(2)2021 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-33883259

RESUMO

The coronavirus disease 2019 (COVID-19) global pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) continues to place an immense burden on societies and health care systems. A key component of COVID-19 control efforts is serological testing to determine the community prevalence of SARS-CoV-2 exposure and quantify individual immune responses to prior SARS-CoV-2 infection or vaccination. Here, we describe a laboratory-developed antibody test that uses readily available research-grade reagents to detect SARS-CoV-2 exposure in patient blood samples with high sensitivity and specificity. We further show that this sensitive test affords the estimation of viral spike-specific IgG titers from a single sample measurement, thereby providing a simple and scalable method to measure the strength of an individual's immune response. The accuracy, adaptability, and cost-effectiveness of this test make it an excellent option for clinical deployment in the ongoing COVID-19 pandemic.IMPORTANCE Serological surveillance has become an important public health tool during the COVID-19 pandemic. Detection of protective antibodies and seroconversion after SARS-CoV-2 infection or vaccination can help guide patient care plans and public health policies. Serology tests can detect antibodies against past infections; consequently, they can help overcome the shortcomings of molecular tests, which can detect only active infections. This is important, especially when considering that many COVID-19 patients are asymptomatic. In this study, we describe an enzyme-linked immunosorbent assay (ELISA)-based qualitative and quantitative serology test developed to measure IgG and IgA antibodies against the SARS-CoV-2 spike glycoprotein. The test can be deployed using commonly available laboratory reagents and equipment and displays high specificity and sensitivity. Furthermore, we demonstrate that IgG titers in patient samples can be estimated from a single measurement, enabling the assay's use in high-throughput clinical environments.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/imunologia , SARS-CoV-2/imunologia , Adolescente , Adulto , Idoso , Especificidade de Anticorpos , COVID-19/epidemiologia , Teste Sorológico para COVID-19/estatística & dados numéricos , Estudos de Casos e Controles , Estudos de Coortes , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/estatística & dados numéricos , Monitoramento Epidemiológico , Feminino , Humanos , Imunoglobulina A/sangue , Imunoglobulina G/sangue , Masculino , Pessoa de Meia-Idade , Pandemias , Estudos Soroepidemiológicos , Glicoproteína da Espícula de Coronavírus/imunologia , Adulto Jovem
12.
Clin Chem ; 56(6): 921-9, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20395622

RESUMO

BACKGROUND: Because total thyroid hormone testing is performed on many automated clinical chemistry instruments, the IFCC Scientific Division commissioned the Working Group for Standardization of Thyroid Function Tests to include total thyroxine (TT4) and total triiodothyronine (TT3) in its standardization efforts. METHODS: Existing SI-traceable reference measurement procedures (RMPs) were used to assign TT4 and TT3 values to 40 single-donor serum samples for subsequent use in a method comparison study with 11 TT4 and 12 TT3 immunoassays. Data from comparison of each immunoassay with the RMPs provided a basis for mathematical assay recalibration. RESULTS: Seven TT4 assays had a mean bias within 10% of the RMP, but 2 deviated by an average of -12% and another 2 by +17%. All TT3 assays showed positive biases, 4 within and 8 outside 10%, up to 32%. Mathematical recalibration effectively eliminated assay-specific biases, but sample-related effects remained, particularly for TT3. Correlation coefficients with the RMPs ranged from 0.82 to 0.97 for TT4 and from 0.32 to 0.92 for TT3. The within-run and total imprecision ranges for TT4 were 1.4% to 9.1% and 3.0% to 9.4%, respectively, and for TT3 2.1% to 7.8% and 2.8% to 12.7%, respectively. Approximately one-half of the assays matched the internal QC targets within approximately 5%; however, we observed within-run drifts/shifts. CONCLUSIONS: The study showed that of the assays we examined, only 4 TT4 but the majority of the TT3 assays needed establishment of calibration traceability to the existing RMPs. Most assays performed well, but some would benefit from improved precision, within-run stability, and between-run consistency.


Assuntos
Testes de Função Tireóidea/métodos , Testes de Função Tireóidea/normas , Tiroxina/sangue , Tri-Iodotironina/sangue , Calibragem , Humanos , Imunoensaio/métodos , Imunoensaio/normas
13.
Clin Chem ; 56(6): 912-20, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20395623

RESUMO

BACKGROUND: Free thyroxine (FT4) and free triiodothyronine (FT3) measurements are useful in the diagnosis and treatment of a variety of thyroid disorders. The IFCC Scientific Division established a Working Group to resolve issues of method performance to meet clinical requirements. METHODS: We compared results for measurement of a panel of single donor sera using clinical laboratory procedures based on equilibrium dialysis-isotope dilution-mass spectrometry (ED-ID-MS) (2 for FT4, 1 for FT3) and immunoassays from 9 manufacturers (15 for FT4, 13 for FT3) to a candidate international conventional reference measurement procedure (cRMP) also based on ED-ID-MS. RESULTS: For FT4 (FT3), the mean bias of 2 (4) assays was within 10% of the cRMP, whereas for 15 (9) assays, negative biases up to -42% (-30%) were seen; 1 FT3 assay was positively biased by +22%. Recalibration to the cRMP eliminated assay-specific biases; however, sample-related effects remained, as judged from difference plots with biologic total error limits. Correlation coefficients to the cRMPs ranged for FT4 (FT3) from 0.92 to 0.78 (0.88 to 0.30). Within-run and total imprecision ranged for FT4 (FT3) from 1.0% to 11.1% (1.8% to 9.4%) and 1.5% to 14.1% (2.4% to 10.0%), respectively. Approximately half of the manufacturers matched the internal QC targets within approximately 5%; however, within-run instability was observed. CONCLUSIONS: The study showed that most assays had bias largely correctable by establishing calibration traceability to a cRMP and that the majority performed well. Some assays, however, would benefit from improved precision, within-run stability, and between-run consistency.


Assuntos
Testes de Função Tireóidea/métodos , Testes de Função Tireóidea/normas , Tiroxina/sangue , Tri-Iodotironina/sangue , Calibragem , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Humanos , Imunoensaio/métodos , Imunoensaio/normas , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas
14.
Clin Chem ; 56(6): 902-11, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20395624

RESUMO

BACKGROUND: Laboratory testing of serum thyroid-stimulating hormone (TSH) is an essential tool for the diagnosis and management of various thyroid disorders whose collective prevalence lies between 4% and 8%. However, between-assay discrepancies in TSH results limit the application of clinical practice guidelines. METHODS: We performed a method comparison study with 40 sera to assess the result comparability and performance attributes of 16 immunoassays. RESULTS: Thirteen of 16 assays gave mean results within 10% of the overall mean. The difference between the most extreme means was 39%. Assay-specific biases could be eliminated by recalibration to the overall mean. After recalibration of singlicate results, all assays showed results within the biological total error goal (22.8%), except for 1 result in each of 4 assays. For a sample with a TSH concentration of 0.016 mIU/L, 6 assays either did not report results or demonstrated CVs >20%. Within-run and total imprecision ranged from 1.5% to 5.5% and 2.5% to 7.7%, respectively. Most assays were able to match the internal QC targets within 5%. Within-run drifts and shifts were observed. CONCLUSIONS: Harmonization of TSH measurements would be particularly beneficial for 3 of the 16 examined assays. These data demonstrate that harmonization may be accomplished by establishing calibration traceability to the overall mean values for a panel of patient samples. However, the full impact of the approach must be further explored with a wider range of samples. Although a majority of assays showed excellent quality of performance, some would benefit from improved within-run stability.


Assuntos
Testes de Função Tireóidea/métodos , Testes de Função Tireóidea/normas , Tireotropina/sangue , Calibragem , Humanos , Imunoensaio/métodos , Imunoensaio/normas
15.
Transplantation ; 104(7): 1396-1402, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31651793

RESUMO

BACKGROUND: Model for End-Stage Liver Disease (MELD) score-based liver transplant allocation was implemented as a fair and objective measure to prioritize patients based upon disease severity. Accuracy and reproducibility of MELD is an essential assumption to ensure fairness in organ access. We hypothesized that variability in laboratory methodology between centers could impact allocation scores for individuals on the transplant waiting list. METHODS: Aliquots of 30 patient serum samples were analyzed for creatinine, bilirubin, and sodium in all transplant centers within United Network for Organ Sharing (UNOS) region 9. Descriptive statistics, intraclass correlation coefficients (ICCs), and linear mixed-effects regression were used to determine the relationship between center, bilirubin, and calculated MELD-sodium (MELD-Na) score. RESULTS: The mean MELD-Na score per sample ranged from 14 to 38. The mean range in MELD-Na per sample was 3 points, but 30% of samples had a range of 4-6 points. Correlation plots and intraclass correlation coefficient analysis confirmed bilirubin interfered with creatinine, with worsening agreement in creatinine at high bilirubin levels. Center and bilirubin were independently associated with creatinine reported in mixed-effects models. Unbiased hierarchical clustering suggested that samples from specific centers have consistently higher creatinine and MELD-Na values. CONCLUSIONS: Despite implementation of creatinine standardization, centers within a single UNOS region report clinically significant differences in MELD-Na on an identical sample, with differences of up to 6 points in high MELD-Na patients. The bias in MELD-Na scores based upon center choice within a region should be addressed in the current efforts to eliminate disparities in liver transplant access.


Assuntos
Doença Hepática Terminal/diagnóstico , Transplante de Fígado/normas , Alocação de Recursos/normas , Índice de Gravidade de Doença , Centros de Atenção Terciária/normas , Aloenxertos/provisão & distribuição , Bilirrubina/sangue , Serviços de Laboratório Clínico/normas , Creatinina/sangue , Definição da Elegibilidade/normas , Doença Hepática Terminal/sangue , Humanos , Seleção de Pacientes , Guias de Prática Clínica como Assunto , Padrões de Referência , Reprodutibilidade dos Testes , Sódio/sangue , Estados Unidos , Listas de Espera
16.
medRxiv ; 2020 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-32935116

RESUMO

The COVID-19 global pandemic caused by severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) continues to place an immense burden on societies and healthcare systems. A key component of COVID-19 control efforts is serologic testing to determine the community prevalence of SARS-CoV-2 exposure and quantify individual immune responses to prior infection or vaccination. Here, we describe a laboratory-developed antibody test that uses readily available research-grade reagents to detect SARS-CoV-2 exposure in patient blood samples with high sensitivity and specificity. We further show that this test affords the estimation of viral spike-specific IgG titers from a single sample measurement, thereby providing a simple and scalable method to measure the strength of an individual's immune response. The accuracy, adaptability, and cost-effectiveness of this test makes it an excellent option for clinical deployment in the ongoing COVID-19 pandemic.

18.
Cancer Res ; 65(14): 6151-8, 2005 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-16024616

RESUMO

Tumor hypoxia modifies the efficacy of conventional anticancer therapy and promotes malignant tumor progression. Human chorionic gonadotropin (hCG) is a glycoprotein secreted during pregnancy that has been used to monitor tumor burden in xenografts engineered to express this marker. We adapted this approach to use urinary beta-hCG as a secreted reporter protein for tumor hypoxia. We used a hypoxia-inducible promoter containing five tandem repeats of the hypoxia-response element (HRE) ligated upstream of the beta-hCG gene. This construct was stably integrated into two different cancer cell lines, FaDu, a human head and neck squamous cell carcinoma, and RKO, a human colorectal cancer cell line. In vitro studies showed that tumor cells stably transfected with this plasmid construct secrete beta-hCG in response to hypoxia or hypoxia-inducible factor 1alpha (HIF-1alpha) stabilizing agents. The hypoxia responsiveness of this construct can be blocked by treatment with agents that affect the HIF-1alpha pathways, including topotecan, 1-benzyl-3-(5'-hydroxymethyl-2'-furyl)indazole (YC-1), and flavopiridol. Immunofluorescent analysis of tumor sections and quantitative assessment with flow cytometry indicate colocalization between beta-hCG and 2-(2-nitro-1H-imidazol-1-yl)-N-(2,2,3,3,3-pentafluoropropyl)acetamide (EF5) and beta-hCG and pimonidazole, two extrinsic markers for tumor hypoxia. Secretion of beta-hCG from xenografts that contain these stable constructs is directly responsive to changes in tumor oxygenation, including exposure of the animals to 10% O2 and tumor bed irradiation. Similarly, urinary beta-hCG levels decline after treatment with flavopiridol, an inhibitor of HIF-1 transactivation. This effect was observed only in tumor cells expressing a HRE-regulated reporter gene and not in tumor cells expressing a cytomegalovirus-regulated reporter gene. The 5HRE beta-hCG reporter system described here enables serial, noninvasive monitoring of tumor hypoxia in a mouse model by measuring a urinary reporter protein.


Assuntos
Carcinoma de Células Escamosas/metabolismo , Gonadotropina Coriônica Humana Subunidade beta/genética , Neoplasias Colorretais/metabolismo , Neoplasias de Cabeça e Pescoço/metabolismo , Animais , Carcinoma de Células Escamosas/tratamento farmacológico , Carcinoma de Células Escamosas/genética , Carcinoma de Células Escamosas/urina , Hipóxia Celular/fisiologia , Linhagem Celular Tumoral , Gonadotropina Coriônica Humana Subunidade beta/urina , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/genética , Neoplasias Colorretais/urina , Proteínas de Ligação a DNA/genética , Flavonoides/farmacologia , Genes Reporter/genética , Vetores Genéticos/genética , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Neoplasias de Cabeça e Pescoço/genética , Neoplasias de Cabeça e Pescoço/urina , Humanos , Fator 1 Induzível por Hipóxia , Subunidade alfa do Fator 1 Induzível por Hipóxia , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos SENCAR , Transplante de Neoplasias , Proteínas Nucleares/genética , Piperidinas/farmacologia , Topotecan/farmacologia , Fatores de Transcrição/genética , Transfecção , Transplante Heterólogo
19.
Arch Pathol Lab Med ; 141(1): 93-97, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27763779

RESUMO

CONTEXT: -Syphilis serology screening in laboratory practice is evolving. Traditionally, the syphilis screening algorithm begins with a nontreponemal immunoassay, which is manually performed by a laboratory technologist. In contrast, the reverse algorithm begins with a treponemal immunoassay, which can be automated. The Centers for Disease Control and Prevention has recognized both approaches, but little is known about the current state of laboratory practice, which could impact test utilization and interpretation. OBJECTIVE: -To assess the current state of laboratory practice for syphilis serologic screening. DESIGN: -In August 2015, a voluntary questionnaire was sent to the 2360 laboratories that subscribe to the College of American Pathologists syphilis serology proficiency survey. RESULTS: -Of the laboratories surveyed, 98% (2316 of 2360) returned the questionnaire, and about 83% (1911 of 2316) responded to at least some questions. Twenty-eight percent (378 of 1364) reported revision of their syphilis screening algorithm within the past 2 years, and 9% (170 of 1905) of laboratories anticipated changing their screening algorithm in the coming year. Sixty-three percent (1205 of 1911) reported using the traditional algorithm, 16% (304 of 1911) reported using the reverse algorithm, and 2.5% (47 of 1911) reported using both algorithms, whereas 9% (169 of 1911) reported not performing a reflex confirmation test. Of those performing the reverse algorithm, 74% (282 of 380) implemented a new testing platform when introducing the new algorithm. CONCLUSION: -The majority of laboratories still perform the traditional algorithm, but a significant minority have implemented the reverse-screening algorithm. Although the nontreponemal immunologic response typically wanes after cure and becomes undetectable, treponemal immunoassays typically remain positive for life, and it is important for laboratorians and clinicians to consider these assay differences when implementing, using, and interpreting serologic syphilis screening algorithms.


Assuntos
Algoritmos , Laboratórios/estatística & dados numéricos , Ensaio de Proficiência Laboratorial/estatística & dados numéricos , Inquéritos e Questionários , Sorodiagnóstico da Sífilis/estatística & dados numéricos , American Medical Association , Humanos , Laboratórios/normas , Ensaio de Proficiência Laboratorial/normas , Programas de Rastreamento/métodos , Programas de Rastreamento/normas , Programas de Rastreamento/estatística & dados numéricos , Patologistas , Patologia Clínica/organização & administração , Patologia Clínica/normas , Patologia Clínica/estatística & dados numéricos , Prevalência , Sensibilidade e Especificidade , Sífilis/diagnóstico , Sífilis/epidemiologia , Sorodiagnóstico da Sífilis/métodos , Sorodiagnóstico da Sífilis/normas , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA