RESUMO
We describe the concept of a new imaging modality based on the tracking and dynamic modeling of local intensity changes (ICs) observed in conventional ultrasound images collected during a medium-temperature change. We computed the pixel-by-pixel IC from averaged B-mode images that exhibited different behaviors with varying temperature resulting from changes in the speed of sound, which consequently induce changes in the backscattered energy. Moreover, for each pixel, a first-order polynomial model was adjusted to the different temperature-dependent ICs. The representation of the polynomial angular parameter in 2D pixel space was used to obtain a parametric image. The results obtained by simulations and with real B-mode images indicated that this new ultrasound imaging modality was able to enhance the contrast and highlight structures that were poorly visible or even undetected in conventional images. A temperature change of 3°C was found to be sufficient to generate appropriate images with the proposed method. In addition, if a temperature change of 6°C was considered, the thermal dose, measured as the cumulative number of equivalent minutes at 43°C (CEM43°C), was 2.4 CEM43°C, which is a value that is considered safe according to the literature. We provide a proof-of-concept of a new imaging modality that opens new opportunities for the enhancement of ultrasound images and consequently contributes to improvements in ultrasound-based diagnoses. Our approach is based on images returned by commercial ultrasound scanners. Therefore, it can be implemented in any ultrasound system and is independent of specific ultrasound hardware and software data acquisition characteristics.
Assuntos
Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Temperatura , Ultrassonografia/métodos , Algoritmos , Animais , Simulação por Computador , Estudos de Viabilidade , Modelos Animais , Modelos Estatísticos , SuínosRESUMO
A simple experimental protocol applying a quantitative ultrasound (QUS) pulse-echo technique was used to measure the acoustic parameters of healthy femoral diaphyses of Wistar rats in vivo. Five quantitative parameters [apparent integrated backscatter (AIB), frequency slope of apparent backscatter (FSAB), time slope of apparent backscatter (TSAB), integrated reflection coefficient (IRC), and frequency slope of integrated reflection (FSIR)] were calculated using the echoes from cortical and trabecular bone in the femurs of 14 Wistar rats. Signal acquisition was performed three times in each rat, with the ultrasound signal acquired along the femur's central region from three positions 1 mm apart from each other. The parameters estimated for the three positions were averaged to represent the femur diaphysis. The results showed that AIB, FSAB, TSAB, and IRC values were statistically similar, but the FSIR values from Experiments 1 and 3 were different. Furthermore, Pearson's correlation coefficient showed, in general, strong correlations among the parameters. The proposed protocol and calculated parameters demonstrated the potential to characterize the femur diaphysis of rats in vivo. The results are relevant because rats have a bone structure very similar to humans, and thus are an important step toward preclinical trials and subsequent application of QUS in humans.
Assuntos
Densidade Óssea/fisiologia , Fêmur/diagnóstico por imagem , Ultrassonografia/métodos , Animais , Diáfises/diagnóstico por imagem , Invenções , Modelos Biológicos , Ratos Wistar , Estatísticas não ParamétricasRESUMO
A simple experimental protocol applying a quantitative ultrasound (QUS) pulse-echo technique was used to measure the acoustic parameters of healthy femoral diaphyses of Wistar rats in vivo. Five quantitative parameters [apparent integrated backscatter (AIB), frequency slope of apparent backscatter (FSAB), time slope of apparent backscatter (TSAB), integrated reflection coefficient (IRC), and frequency slope of integrated reflection (FSIR)] were calculated using the echoes from cortical and trabecular bone in the femurs of 14 Wistar rats. Signal acquisition was performed three times in each rat, with the ultrasound signal acquired along the femur's central region from three positions 1 mm apart from each other. The parameters estimated for the three positions were averaged to represent the femur diaphysis. The results showed that AIB, FSAB, TSAB, and IRC values were statistically similar, but the FSIR values from Experiments 1 and 3 were different. Furthermore, Pearson's correlation coefficient showed, in general, strong correlations among the parameters. The proposed protocol and calculated parameters demonstrated the potential to characterize the femur diaphysis of rats in vivo. The results are relevant because rats have a bone structure very similar to humans, and thus are an important step toward preclinical trials and subsequent application of QUS in humans.