RESUMO
PURPOSE: In Germany, Austria, and Switzerland, pretreatment radiotherapy quality control (RT-QC) for tumor bed boost (TB) in non-metastatic medulloblastoma (MB) was not mandatory but was recommended for patients enrolled in the SIOP PNET5 MB trial between 2014 and 2018. This individual case review (ICR) analysis aimed to evaluate types of deviations in the initial plan proposals and develop uniform review criteria for TB boost. PATIENTS AND METHODS: A total of 78 patients were registered in this trial, of whom a subgroup of 65 patients were available for evaluation of the TB treatment plans. Dose uniformity was evaluated according to the definitions of the protocol. Additional RT-QC criteria for standardized review of target contours were elaborated and data evaluated accordingly. RESULTS: Of 65 initial TB plan proposals, 27 (41.5%) revealed deviations of target volume delineation. Deviations according to the dose uniformity criteria were present in 14 (21.5%) TB plans. In 25 (38.5%) cases a modification of the RT plan was recommended. Rejection of the TB plans was rather related to unacceptable target volume delineation than to insufficient dose uniformity. CONCLUSION: In this analysis of pretreatment RT-QC, protocol deviations were present in a high proportion of initial TB plan proposals. These findings emphasize the importance of pretreatment RT-QC in clinical trials for MB. Based on these data, a proposal for RT-QC criteria for tumor bed boost in non-metastatic MB was developed.
Assuntos
Neoplasias Cerebelares , Meduloblastoma , Radioterapia (Especialidade) , Neoplasias Cerebelares/radioterapia , Alemanha , Humanos , Meduloblastoma/radioterapia , Controle de Qualidade , Planejamento da Radioterapia Assistida por ComputadorRESUMO
BACKGROUND: Eye-preserving therapy in retinoblastoma comprises systemic chemotherapy, but studies analyzing the efficacy of different chemotherapy regimens are scarce. METHODS: The efficacy and side effects of two different eye-preserving chemotherapy regimens containing either vincristine, etoposide, and carboplatin (VEC) or cyclophosphamide, vincristine, etoposide, and carboplatin (CyVEC) were compared in a prospective non-interventional observational study including children diagnosed with retinoblastoma between 2013 and 2019 in Germany and Austria. Event-free eye survival (EFES) and overall eye survival (OES) of all 164 eyes treated with both regimens and risk factors were investigated. RESULTS: The EFES after VEC (2-year EFES 72.3%) was higher than after CyVEC (2-year EFES 50.4%) (plogrank < .001). The OES did not differ significantly between the two treatment groups (plogrank = .77; 2-year OES VEC: 82.1% vs. CyVEC: 84.8%). Advanced International Classification of Retinoblastoma (ICRB) group was prognostic for a lower EFES (plogrank < .0001; 2-year EFES ICRB A/B/C 71.3% vs. ICRB D/E 43.0%) and OES (plogrank < .0001; 2-year OES ICRB A/B/C 93.1% vs. ICRB D/E 61.5%). The multivariate analysis showed that age at diagnosis older than 12 months and ICRB A/B/C were associated with better EFES. No second malignancies or ototoxicities were reported after a follow-up of median 3.1 years after diagnosis of retinoblastoma (range 0.1-6.9 years). CONCLUSIONS: Despite omitting cyclophosphamide, the EFES was higher after VEC chemotherapy that contains higher doses of carboplatin compared to CyVEC. The major risk factor for enucleation was advanced ICRB tumor grouping. Randomized clinical trials on efficacy and side effects of eye-preserving chemotherapy are required to tailor treatment protocols for retinoblastoma patients.
Assuntos
Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Neoplasias da Retina , Retinoblastoma , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Carboplatina , Criança , Ciclofosfamida , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/tratamento farmacológico , Etoposídeo , Enucleação Ocular , Humanos , Estudos Prospectivos , Neoplasias da Retina/tratamento farmacológico , Neoplasias da Retina/patologia , Retinoblastoma/tratamento farmacológico , Retinoblastoma/patologia , VincristinaRESUMO
PURPOSE: Several studies have demonstrated the negative impact of radiotherapy protocol deviations on tumor control in medulloblastoma. In the SIOP PNET5 MB trial, a pretreatment radiotherapy quality control (RT-QC) program was introduced. A first analysis for patients enrolled in Germany, Switzerland and Austria with focus on types of deviations in the initial plan proposals and review criteria for modern radiation technologies was performed. METHODS AND PATIENTS: Sixty-nine craniospinal irradiation (CSI) plans were available for detailed analyses. RT-QC was performed according to protocol definitions on dose uniformity. Because of the lack of definitions for high-precision 3D conformal radiotherapy within the protocol, additional criteria for RT-QC on delineation and coverage of clinical target volume (CTV) and planning target volume (PTV) were defined and evaluated. RESULTS: Target volume (CTV/PTV) deviations occurred in 49.3% of initial CSI plan proposals (33.3% minor, 15.9% major). Dose uniformity deviations were less frequent (43.5%). Modification of the RT plan was recommended in 43.5% of CSI plans. Unacceptable RT plans were predominantly related to incorrect target delineation rather than dose uniformity. Unacceptable plans were negatively correlated to the number of enrolled patients per institution with a cutoff of 5 patients (pâ¯= 0.001). CONCLUSION: This prospective pretreatment individual case review study revealed a high rate of deviations and emphasizes the strong need of pretreatment RT-QC in clinical trials for medulloblastoma. Furthermore, the experiences point out the necessity of new RT-QC criteria for high-precision CSI techniques.
Assuntos
Neoplasias Cerebelares/radioterapia , Radiação Cranioespinal/métodos , Meduloblastoma/radioterapia , Adolescente , Adulto , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Alemanha , Humanos , Masculino , Estudos Prospectivos , Controle de Qualidade , Radioterapia (Especialidade) , Adulto JovemRESUMO
BACKGROUND: Adequate management of retinoblastoma requires a multidisciplinary and individual approach to treatment. Intraarterial chemotherapy (IAC) is one of the most commonly used treatment modalities, and enables supraselective application of chemotherapy via the ophthalmic artery and is now established in almost all treatment centres. However, published treatment success rates are heterogeneous. There are some unanswered issues regarding sight-threatening ocular complications and the long-term occurrence of secondary malignancies and metastatic disease. The objective of the present study is to analyse the results of a German national reference centre. METHODS: Retrospective analysis of all children with an indication for at least one IAC from April 2010 to April 2020. IAC was used either as primary or recurrence therapy. Obligatory follow-up was at least 6 months. RESULTS: 137 eyes of 127 children with an indication for IAC could be included. 12 eyes with a follow-up of less than 6 months and 37 eyes in which IAC was technically not feasible were excluded. In summary, 88 eyes of 79 children were finally analysed. Mean follow-up was 38 months, ranging from 7 to 117 months. In total, 195 procedures were completed. In 30 eyes (34.1%) IAC was conducted as primary and in 58 (65.9%) as secondary therapy. There was an initial IAC treatment response in 75 eyes (85.2%) with a recurrence-free rate of 61.3%. Eye salvage rate was 68.1% with 28 enucleated eyes in total. Ocular complications were observed in 36 eyes (40.9%), with 19 eyes (21.6%) showing severe sight-threatening and 11 eyes (12.5%) presenting minor non-sight-threatening toxic reactions. During follow-up, 1 child developed a secondary malignancy, 1 child developed metastasis and 1 child died as a consequence of trilateral retinoblastoma. CONCLUSION: In summary, IAC is a potent modality for retinoblastoma treatment and has been very successful, even in advanced disease and heavily pretreated eyes. However, ocular complications should be taken in consideration, especially when the only seeing eye is treated. Long term incidences of secondary malignancies and metastatic diseases should be further investigated in prospective studies.
Assuntos
Neoplasias da Retina , Retinoblastoma , Criança , Humanos , Lactente , Recidiva Local de Neoplasia , Estudos Prospectivos , Neoplasias da Retina/tratamento farmacológico , Retinoblastoma/tratamento farmacológico , Estudos RetrospectivosRESUMO
BACKGROUND: The aim of this study is to examine the dosimetric influence of endorectal balloons (ERB) on rectal sparing in prostate cancer patients with implanted hydrogel rectum spacers treated with dose-escalated or hypofractionated intensity-modulated proton beam therapy (IMPT). METHODS: Ten patients with localized prostate cancer included in the ProRegPros study and treated at our center were investigated. All patients underwent placement of hydrogel rectum spacers before planning. Two planning CTs (with and without 120 cm3 fluid-filled ERB) were applied for each patient. Dose prescription was set according to the h strategy, with 72 Gray (Gy)/2.4 Gy/5× weekly to prostate + 1 cm of the seminal vesicle, and 60 Gy/2 Gy/5× weekly to prostate + 2 cm of the seminal vesicle. Planning with two laterally opposed IMPT beams was performed in both CTs. Rectal dosimetry values including dose-volume statistics and normal tissue complication probability (NTCP) were compared for both plans (non-ERB plans vs. ERB plans). RESULTS: For ERB plans compared with non-ERB, the reductions were 8.51 ± 5.25 Gy (RBE) (p = 0.000) and 15.76 ± 11.11 Gy (p = 0.001) for the mean and the median rectal doses, respectively. No significant reductions in rectal volumes were found after high dose levels. The use of ERB resulted in significant reduction in rectal volume after receiving 50 Gy (RBE), 40 Gy (RBE), 30 Gy (RBE), 20 Gy (RBE), and 10 Gy (RBE) with p values of 0.034, 0.008, 0.003, 0.001, and 0.001, respectively. No differences between ERB and non-ERB plans for the anterior rectum were observed. ERB reduced posterior rectal volumes in patients who received 30 Gy (RBE), 20 Gy (RBE), or 10 Gy (RBE), with p values of 0.019, 0.003, and 0.001, respectively. According to the NTCP models, no significant reductions were observed in mean or median rectal toxicity (late rectal bleeding ≥ 2, necrosis or stenosis, and late rectal toxicity ≥ 3) when using the ERB. CONCLUSION: ERB reduced rectal volumes exposed to intermediate or low dose levels. However, no significant reduction in rectal volume was observed in patients receiving high or intermediate doses. There was no benefit and also no disadvantage associated with the use of ERB for late rectal toxicity, according to available NTCP models.
Assuntos
Neoplasias da Próstata , Terapia com Prótons , Masculino , Humanos , Reto , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias da Próstata/radioterapia , HidrogéisRESUMO
Proton radiotherapy of the prostate basal or whole seminal vesicles using scattering delivery systems is an effective treatment of prostate cancer that has been evaluated in prospective trials. Meanwhile, the use of pencil beam scanning (PBS) can further reduce the dose in the beam entrance channels and reduce the dose to the normal tissues. However, PBS dose distributions can be affected by intra- and interfractional motion. In this treatment planning study, the effects of intra- and interfractional organ motion on PBS dose distributions are investigated using repeated CT scans at close and distant time intervals. The minimum dose (Dmin) and the dose to 2% and 98% of the volumes (D2% and D98%), as well as EUD in the clinical target volumes (CTV), is used as measure of robustness. In all patients, D98% was larger than 96% and D2% was less than 106% of the prescribed dose. The combined information from Dmin, D98% and EUD led to the conclusion that there are no relevant cold spots observed in any of the verification plans. Moreover, it was found that results of single field optimization are more robust than results from multiple field optimizations.
Assuntos
Neoplasias da Próstata/radioterapia , Prótons , Humanos , Masculino , Movimento (Física) , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios XRESUMO
PURPOSE: To evaluate the impact of beam quality in terms of distal fall-off (DFO, 90%-10%) and lateral penumbra (LP, 80%-20%) of single beam ocular proton therapy (OPT) and to derive resulting ideal requirements for future systems. METHODS: Nine different beam models with DFO varying between 1 and 4 mm and LP between 1 and 4 mm were created. Beam models were incorporated into the RayStation with RayOcular treatment planning system version 10 B (RaySearch Laboratories, Stockholm, Sweden). Each beam model was applied for eight typical clinical cases, covering different sizes and locations of uveal melanoma. Plans with and without an additional wedge were created, resulting in 117 plans with a total prescribed median dose of 60 Gy(RBE) to the clinical target volume. Treatment plans were analyzed in terms of V20-V80 penumbra volume, D1 (dose to 1% of the volume) for optic disc and macula, optic nerve V30 (volume receiving 30 Gy(RBE), i.e., 50% of prescription), as well as average dose to lens and ciliary body. An LP-dependent aperture margin was based on estimated uncertainties, ranging from 1.7 to 4.0 mm. RESULTS: V20-V80 showed a strong influence by LP, while DFO was less relevant. The optic disc D1 reached an extra dose of up to 3000 cGy(RBE), comparing the defined technical limit of DFO = LP = 1 mm with DFO = 3 mm/LP = 4 mm. The latter may result from a pencil-beam scanning (PBS) system with static apertures. Plans employing a wedge showed an improvement for organs at risk sparing. CONCLUSION: Plan quality is strongly influenced by initial beam parameters. The impact of LP is more pronounced when compared to DFO. The latter becomes important in the treatment of posterior tumors near the macula, optic disc or optic nerve. The plan quality achieved by dedicated OPT nozzles in single- or double-scattering design might not be achievable with modified PBS systems.
Assuntos
Terapia com Prótons , Neoplasias Uveais , Humanos , Melanoma , Órgãos em Risco , Terapia com Prótons/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Uveais/radioterapiaRESUMO
PURPOSE: To examine the dosimetric feasibility of hypofractionated/dose escalated radiation therapy in patients with localized prostate carcinoma using simultaneous integrated boost intensity-modulated proton beam therapy (SIB-IMPT) in absence or presence of prostate-rectum spacer. METHODS: IMPT technique was implemented in 23 patients with intermediate- and high-risk prostate cancer treated at West German Proton Therapy Centre from March 2016 till June 2018, using SIB technique prescribing 60 GyRBE and 72â¯GyRBE in 30 fractions to PTV1 (prostate and seminal vesicle) and PTV2 boost (prostate and proximal seminal vesicle), respectively. In 15 patients, a transperineal injection of hydrogel was applied prior to radiotherapy to increase the distance between prostate and rectum. Planning and all treatments were performed with a 120 ml fluid-filled endorectal balloon customised daily for each patient. For each patient, 2 lateral IMPT beams were implemented taking a field-specific range uncertainty (RU) into account. Dose volume histograms (DVH) were analyzed for PTV2, PTV2 with range uncertainty margin (PTV2RU), rectum, bladder, right/left femoral heads, and penile bulb. For late rectal toxicities, the normal tissue complication probabilities (NTCP) were calculated using different biological models. A DVH- and NTCP-based dosimetric comparison was carried out between non-spacer and spacer groups. RESULTS: For the 23 patients, high-quality plans could be achieved for target volume and for other organs at risk (OARs). For PTV2, the V107% was 0% and the Dmax did not exceed 106.2% of the prescribed dose. The volume PTV2RU covered by 95% of the dose ranged from 96.16 to 99.95%. The conformality index for PTV2RU was 1.12 ± 0.057 and the homogeneity index (HI) was 1.04 ± 0.014. Rectum Dmax and rectal volume receiving 73-50 Gy could be further reduced for the spacer-group. Significant reductions in mean and median rectal NTCPs (stenosis/necrosis, late rectal bleeding ≥ 2, and late rectal toxicities ≥ 3) were predicted for the spacer group in comparison to the non-spacer group. CONCLUSION: Hypofractionated/dose escalated radiotherapy with SIB-IMPT is dosimetrically feasible. Further reduction of the rectal volumes receiving high and medium dose levels (73-50 Gy) and rectal NTCP could be achieved through injection of spacers between rectum and prostate.
Assuntos
Neoplasias da Próstata , Terapia com Prótons , Estudos de Viabilidade , Humanos , Hidrogéis , Masculino , Próstata/patologia , Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Reto/patologiaRESUMO
Proton therapy makes use of the favorable depth-dose distribution with its characteristic Bragg peak to spare normal tissue distal of the target volume. A steep dose gradient would be desired in lateral dimensions, too. The widespread spot scanning delivery technique is based, however, on pencil-beams with in-air spot full-widths-at-half-maximum of typically 1 cm or more. This hampers the sparing of organs-at-risk if small-scale structures adjacent to the target volume are concerned. The trimming of spot scanning fields with collimating apertures constitutes a simple measure to increase the transversal dose gradient. The current study describes the clinical implementation of brass apertures in conjunction with the pencil-beam scanning delivery mode at a horizontal, clinical treatment head based on commercial hardware and software components. Furthermore, clinical cases, which comprised craniopharyngiomas, re-irradiations and ocular tumors, were evaluated. The dosimetric benefits of 31 treatment plans using apertures were compared to the corresponding plans without aperture. Furthermore, an overview of the radiation protection aspects is given. Regarding the results, robust optimization considering range and setup uncertainties was combined with apertures. The treatment plan optimizations followed a single-field uniform dose or a restricted multi-field optimization approach. Robustness evaluation was expanded to account for possible deviations of the center of the pencil-beam delivery and the mechanical center of the aperture holder. Supplementary apertures improved the conformity index on average by 15.3%. The volume of the dose gradient surrounding the PTV (evaluated between 80 and 20% dose levels) was decreased on average by 17.6%. The mean dose of the hippocampi could be reduced on average by 2.9 GyRBE. In particular cases the apertures facilitated a sparing of an organ-at-risk, e.g. the eye lens or the brainstem. For six craniopharyngioma cases the inclusion of apertures led to a reduction of the mean dose of 1.5 GyRBE (13%) for the brain and 3.1 GyRBE (16%) for the hippocampi.
RESUMO
The comparison between intensity-modulated proton therapy (IMPT) and volume-modulated arc therapy (VMAT) plans, based on models of normal tissue complication probabilities (NTCP), can support the choice of radiation modality. IMPT irradiation plans for 50 patients with head and neck tumours originally treated with photon therapy have been robustly optimised against density and setup uncertainties. The dose distribution has been calculated with a Monte Carlo (MC) algorithm. The comparison of the plans was based on dose-volume parameters in organs at risk (OARs) and NTCP-calculations for xerostomia, sticky saliva, dysphagia and tube feeding using Langendijk's model-based approach. While the dose distribution in the target volumes is similar, the IMPT plans show better protection of OARs. Therefore, it is not the high dose confirmation that constitutes the advantage of protons, but it is the reduction of the mid-to-low dose levels compared to photons. This work investigates to what extent the advantages of proton radiation are beneficial for the patient's post-therapeutic quality of life (QoL). As a result, approximately one third of the patients examined benefit significantly from proton therapy with regard to possible late side effects. Clinical data is needed to confirm the model-based calculations.
Assuntos
Modelos Teóricos , Órgãos em Risco/efeitos da radiação , Radioterapia de Intensidade Modulada/efeitos adversos , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Probabilidade , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por ComputadorRESUMO
BACKGROUND: The limited availability of proton beam therapy (PBT) requires individual treatment selection strategies, such as the model-based approach. In this study, we assessed the dosimetric benefit of PBT compared to photon therapy (XRT), analysed the corresponding changes in normal tissue complication probability (NTCP) on a variety of available models, and illustrated model-based patient selection in an in-silico study for patients with brain tumours. METHODS: For 92 patients treated at two PBT centres, volumetric modulated arc therapy treatment plans were retrospectively created for comparison with the clinically applied PBT plans. Several dosimetric parameters for the brain excluding tumour and margins, cerebellum, brain stem, frontal and temporal lobes, hippocampi, cochleae, chiasm, optic nerves, lacrimal glands, lenses, pituitary gland, and skin were compared between both modalities using Wilcoxon signed-rank tests. NTCP differences (ΔNTCP) were calculated for 11 models predicting brain necrosis, delayed recall, temporal lobe injury, hearing loss, tinnitus, blindness, ocular toxicity, cataract, endocrine dysfunction, alopecia, and erythema. A patient was assumed to be selected for PBT if ΔNTCP exceeded a threshold of 10 percentage points for at least one of the side-effects. RESULTS: PBT substantially reduced the dose in almost all investigated OARs, especially in the low and intermediate dose ranges and for contralateral organs. In general, NTCP predictions were significantly lower for PBT compared to XRT, in particular in ipsilateral organs. Considering ΔNTCP of all models, 80 patients (87.0%) would have been selected for PBT in this in-silico study, mainly due to predictions of a model on delayed recall (51 patients). CONCLUSION: In this study, substantial dose reductions for PBT were observed, mainly in contralateral organs. However, due to the sigmoidal dose response, NTCP was particularly reduced in ipsilateral organs. This underlines that physical dose-volume parameters alone may not be sufficient to describe the clinical relevance between different treatment techniques and highlights potential benefits of NTCP models. Further NTCP models for different modern treatment techniques are mandatory and existing models have to be externally validated in order to implement the model-based approach in clinical practice for cranial radiotherapy.
Assuntos
Neoplasias Encefálicas , Terapia com Prótons , Radioterapia de Intensidade Modulada , Neoplasias Encefálicas/radioterapia , Humanos , Órgãos em Risco , Probabilidade , Terapia com Prótons/efeitos adversos , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/efeitos adversos , Estudos RetrospectivosRESUMO
Despite the increased risk of subsequent primary tumors (SPTs) external beam radiation (EBRT) may be the only therapeutic option to preserve a retinoblastoma eye. Due to their physical properties, proton beam therapy (PBT) offers the possibility to use the effectiveness of EBRT in tumor treatment and to decisively reduce the treatment-related morbidity. We report our experiences of PBT as rescue therapy in a retrospectively studied cohort of 15 advanced retinoblastoma eyes as final option for eye-preserving therapy. The average age at the initiation of PBT was 35 (14-97) months, mean follow-up was 22 (2-46) months. Prior to PBT, all eyes were treated with systemic chemotherapy and a mean number of 7.1 additional treatments. Indication for PBT was non-feasibility of intra-arterial chemotherapy (IAC) in 10 eyes, tumor recurrence after IAC in another 3 eyes and diffuse infiltrating retinoblastoma in 2 eyes. Six eyes (40%) were enucleated after a mean time interval of 4.8 (1-8) months. Cataract formation was the most common complication affecting 44.4% of the preserved eyes, yet 77.8% achieved a visual acuity of >20/200. Two of the 15 children treated developed metastatic disease during follow-up, resulting in a 13.3% metastasis rate. PBT is a useful treatment modality as a rescue therapy in retinoblastoma eyes with an eye-preserving rate of 60%. As patients are at lifetime risk of SPTs consistent monitoring is mandatory.
RESUMO
BACKGROUND: The limited availability of proton beam therapy (PBT) requires individual treatment selection strategies that can be based on normal tissue complication probability (NTCP) models. We developed and externally validated NTCP models for common late side-effects following PBT in brain tumour patients to optimise patients' quality of life. METHODS: Cohorts from three PBT centres (216 patients) were investigated for several physician-rated endpoints at 12 and 24 months after PBT: alopecia, dry eye syndrome, fatigue, headache, hearing and memory impairment, and optic neuropathy. Dose-volume parameters of associated normal tissues and clinical factors were used for logistic regression modelling in a development cohort. Statistically significant parameters showing high area under the receiver operating characteristic curve (AUC) values in internal cross-validation were externally validated. In addition, analyses of the pooled cohorts and of time-dependent generalised estimating equations including all patient data were performed. RESULTS: In the validation study, mild alopecia was related to high dose parameters to the skin [e.g. the dose to 2% of the volume (D2%)] at 12 and 24 months after PBT. Mild hearing impairment at 24 months after PBT was associated with the mean dose to the ipsilateral cochlea. Additionally, the pooled analyses revealed dose-response relations between memory impairment and intermediate to high doses to the remaining brain as well as D2% of the hippocampi. Mild fatigue at 24 months after PBT was associated with D2% to the brainstem as well as with concurrent chemotherapy. Moreover, in generalised estimating equations analysis, dry eye syndrome was associated with the mean dose to the ipsilateral lacrimal gland. CONCLUSION: We developed and in part validated NTCP models for several common late side-effects following PBT in brain tumour patients. Validation studies are required for further confirmation.
Assuntos
Neoplasias Encefálicas , Terapia com Prótons , Estudos de Coortes , Humanos , Probabilidade , Terapia com Prótons/efeitos adversos , Qualidade de VidaRESUMO
Retinoblastoma and other eye tumors in childhood are rare diseases. Many eye tumors are the first signs of a genetic tumor predisposition syndrome and the affected children carry a higher risk of developing other cancers later in life. Clinical and genetic data of all children with eye tumors diagnosed between 2013-2018 in Germany and Austria were collected in a multicenter prospective observational study. In five years, 300 children were recruited into the study: 287 with retinoblastoma, 7 uveal melanoma, 3 ciliary body medulloepithelioma, 2 retinal astrocytoma, 1 meningioma of the optic nerve extending into the eye. Heritable retinoblastoma was diagnosed in 44% of children with retinoblastoma. One child with meningioma of the optic nerve extending into the eye was diagnosed with neurofibromatosis 2. No pathogenic constitutional variant in DICER1 was detected in a child with medulloepithelioma while two children did not receive genetic analysis. Because of the known association with tumor predisposition syndromes, genetic counseling should be offered to all children with eye tumors. Children with a genetic predisposition to cancer should receive a tailored surveillance including detailed history, physical examinations and, if indicated, imaging to screen for other cancer. Early detection of cancers may reduce mortality.
RESUMO
INTRODUCTION: Given the rarity of retinoblastoma and the consequences of accidental vitrectomy in the event of misdiagnosis, reporting on clinical experience in this area is important. OBJECTIVE: The aim of this study was to analyse the management and complications with a focus on local orbital recurrence and metastatic disease in 10 children vitrectomized in an undetected retinoblastoma eye. METHODS: This is a retrospective descriptive case series conducted in a single-centre referral university hospital. RESULTS: From October 1991 to June 2019, 10 patients with a vitrectomy in an unsuspected retinoblastoma eye were included in this study. The main preoperative diagnoses were unilateral inflammation with a suspected lymphoma, uveitis or toxocariasis in 5 cases, vitreous haemorrhage after trauma in 2 cases, and the last 3 were misdiagnosed with Coats disease, rhegmatogenous retinal detachment and congenital cataract. Mean age at surgery was 3 years, ranging from 14 months to 6 and a half years. Nine patients were suffering from unilateral retinoblastoma; these were enucleated and treated with 4-6 cycles of chemotherapy and/or radiation therapy. The sclerotomy sites were infiltrated with tumour cells in 3 cases. In 1 patient, the differential diagnosis of a malignant medulloepithelioma could not be excluded. One patient had bone marrow infiltration on initial presentation; all other patients are healthy without any signs of orbital recurrence or metastatic disease with a mean follow-up of 5.4 years. CONCLUSION: In children, intraocular tumours, including retinoblastoma and medulloepithelioma, should be ruled out before pars plana vitrectomy is performed. If no doubtless preoperative diagnosis can be established, preoperative magnetic resonance imaging is mandatory. If a vitrectomy in a retinoblastoma eye has been performed, immediate enucleation of the eye with subsequent chemotherapy and orbital radiation is effective to avoid local recurrence and systemic metastases.
RESUMO
PURPOSE: The standard of care of childhood parameningeal rhabdomyosarcoma (pRMS) is chemotherapy and local radiation therapy. Protons are increasingly being used to decrease late effects. The aim of the present study is to analyze the pattern of relapse and the correlation with dosimetric factors in pRMS treated with proton therapy. METHODS AND MATERIALS: This retrospective evaluation includes children treated in our institution for pRMS. Information on demographics, treatment, tumor characteristics, and toxicities and outcome was prospectively collected within the in-house registry. For patients presenting with local relapse, a fusion of the dosimetry with magnetic resonance imaging displaying site and geometry of recurrence was performed. RESULTS: Median follow-up time was 2.9 years (0.5-4.7). Forty-six patients were identified in our institution between July 2013 and November 2017. Main characteristics of patients were as follows: 56.5% male, median age 5.1 years (1.3-17.5), 39.1% alveolar histology, 26.1%, 52.2%, 8.7%, and 13% patients with subgroup risk classification D, E/F/G, H, or metastatic, respectively, median total prescribed dose 55.8 Gy (50.4-56.4). Estimated 2-year local control, metastasis-free survival, event-free survival, and overall survival were 83.8%, 87.8%, 76.9%, and 88.9%, respectively. No acute or late local toxicity exceeding grade 3 was observed. Risk-group was identified as prognostic factor for metastasis-free survival in univariate analysis but not in multivariate analysis (trend: P = .09). In this cohort, dosimetric factors did not correlate with outcome. Isolated local failure happened in 5 of the 11 relapses. Local relapses were matched with dosimetry for 6 patients: 4 of them occurred in the high dose volume and 2 in the intermediate or low dose volume. CONCLUSIONS: Proton therapy was effective and well feasible even in a critical cohort. Still, local relapse within the target volume of the radiation therapy remains an important issue in pRMS and new treatment strategies are needed.
Assuntos
Neoplasias Meníngeas/radioterapia , Recidiva Local de Neoplasia , Terapia com Prótons , Rabdomiossarcoma/radioterapia , Adolescente , Análise de Variância , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Criança , Pré-Escolar , Intervalo Livre de Doença , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Lactente , Imageamento por Ressonância Magnética/métodos , Masculino , Neoplasias Meníngeas/diagnóstico por imagem , Neoplasias Meníngeas/mortalidade , Neoplasias Meníngeas/cirurgia , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/mortalidade , Prognóstico , Terapia com Prótons/efeitos adversos , Lesões por Radiação/patologia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Rabdomiossarcoma/diagnóstico por imagem , Rabdomiossarcoma/mortalidade , Rabdomiossarcoma/cirurgia , Rabdomiossarcoma Alveolar/diagnóstico por imagem , Rabdomiossarcoma Alveolar/mortalidade , Rabdomiossarcoma Alveolar/radioterapia , Rabdomiossarcoma Alveolar/cirurgia , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: The limited availability of proton beam therapy (PBT) requires individual treatment selection strategies, such as based on normal tissue complication probability (NTCP). We developed and externally validated NTCP models for common acute side-effects following PBT in brain tumour patients in effort to provide guidance on optimising patient quality of life. METHODS: An exploration cohort including 113 adult brain tumour patients who underwent PBT was investigated for the following endpoints: alopecia, scalp erythema, headache, fatigue and nausea. Dose-volume parameters of associated normal tissues were used for logistic regression modelling. Statistically significant parameters showing high area under the receiver operating characteristic curve (AUC) values in internal cross-validation were externally validated on two cohorts of 71 and 96 patients, respectively. RESULTS: Statistically significant correlations of dose-volume parameters of the skin for erythema and alopecia were found. In internal cross-validation, the following prognostic parameters were selected: V35Gy (absolute volume receiving 35â¯Gy) for erythema grade ≥1, D2% (dose to 2% of the volume) for alopecia grade ≥1 and D5% for alopecia grade ≥2. Validation was successful for both cohorts with AUC >0.75. A bivariable model for fatigue grade ≥1 could not be validated externally. No correlations of dose-volume parameters of the brain were seen for headache or nausea. CONCLUSION: We developed and successfully validated NTCP models for scalp erythema and alopecia in primary brain tumour patients treated with PBT.
Assuntos
Neoplasias Encefálicas/radioterapia , Terapia com Prótons/efeitos adversos , Lesões por Radiação/etiologia , Doença Aguda , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Encefálicas/psicologia , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Probabilidade , Qualidade de Vida , Adulto JovemRESUMO
Respiratory induced organ motion poses a major challenge for high-precision radiotherapy such as pencil beam scanning proton therapy (PBS). In order to employ PBS for target regions affected by respiratory motion, the implementation of dedicated motion mitigation techniques should be considered and residual uncertainties need to be assessed. For the latter purpose, a routine simulating the delivery of a scanned proton beam to a moving target was developed and implemented in the commercial treatment planning system RayStation. The time structure of the beam delivery was extracted from electronic irradiation protocols of the delivery system. Alternatively to electronic irradiation protocols, an empirical time model of the beam delivery was created to allow for prospective estimations of interplay effects between target motion and pencil beam scanning. The experimental validation of the routine was performed using a two-dimensional ionization chamber array and a dynamic phantom. A 4D CT data set, including 10 respiratory phases, provided the spatial temporal information about the phantom motion. The dosimetric comparison of the measured and the calculated dose distribution yielded gamma pass rates above 96% using a 3% dose difference and a 3mm distance to agreement criterion. Thus, a tool for the evaluation of interplay effects is available in a clinical software environment and patient-specific quality assurance can be extended to dynamic treatment scenarios.
Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Simulação por Computador , Tomografia Computadorizada Quadridimensional/normas , Humanos , Neoplasias Pulmonares/radioterapia , Movimentos dos Órgãos , Imagens de Fantasmas , Terapia com Prótons/normas , SoftwareRESUMO
Pencil beam scanning (PBS) proton therapy enables better dose conformality for complex anatomical geometries than passive proton scattering techniques, but is more susceptible to organ motion. This becomes an issue when treating moving tumours in the thorax or abdomen. Novel four-dimensional treatment planning approaches have been developed to increase the robustness of PBS plans against motion. However, their efficacy still needs to be examined by means of 4D dynamically accumulated dose (4DDD) analyses. This study investigates the potential use of 4D robust optimisation to maintain sufficient target coverage in the presence of organ motion, while sparing surrounding healthy tissue, for hepatocellular carcinoma (HCC). The liver is particularly suited to study motion interplay effects since the treatment region exhibits smaller density gradients and more homogeneous tissue than targets in the thorax, making it less prone to range errors. A facility-specific beam time model, developed and experimentally validated previously, was used for the clinical evaluation. 4DDD analyses of eleven target volumes did not show a significant improvement of the target coverage using 4D robust optimisation, but a reduction of the dose to close-by organs at risk. Interplay effects were averaged out for the applied fractionation scheme of 15 fractions. Contrary to PBS, passive double scattering (DS) plans yielded homogeneous 4DDD dose distributions in a single fraction. But, in some cases, they exceeded organ at risk dose limits, which were only satisfied in PBS. The average normal liver dose could be decreased by almost 6% compared to non-robustly optimised PBS plans and by 16% compared to DS plans when implementing 4D robust optimisation. Except for some very small tumours with large motion amplitudes, 4D robustly optimised PBS plans were found to be clinically acceptable even without supplementary motion mitigation techniques.
Assuntos
Carcinoma Hepatocelular/radioterapia , Tomografia Computadorizada Quadridimensional/métodos , Neoplasias Hepáticas/radioterapia , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , HumanosRESUMO
BACKGROUND: We performed a survey using the modified EORTC Facility questionnaire (pFQ) to evaluate the human, technical and organizational resources of particle centers in Europe. MATERIAL AND METHODS: The modified pFQ consisted of 235 questions distributed in 11 sections accessible on line on an EORTC server. Fifteen centers from 8 countries completed the pFQ between May 2015 and December 2015. RESULTS: The average number of patients treated per year and per particle center was 221 (range, 40-557). The majority (66.7%) of centers had pencil beam or raster scanning capability. Four (27%) centers were dedicated to eye treatment only. An increase in the patients-health professional FTE ratio was observed for eye tumor only centers when compared to other centers. All centers treated routinely chordomas/chondrosarcomas, brain tumors and sarcomas but rarely breast cancer. The majority of centers treated pediatric cases with particles. Only a minority of the queried institutions treated non-static targets. CONCLUSIONS: As the number of particle centers coming online will increase, the experience with this treatment modality will rise in Europe. Children can currently be treated in these facilities in a majority of cases. The majority of these centers provide state of the art particle beam therapy.