J Comput Assist Tomogr ; 40(1): 80-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26466115

RESUMO

OBJECTIVE: The aim of the study was to evaluate objective and subjective image qualities of virtual monoenergetic imaging (VMI) in dual-source dual-energy computed tomography (DECT) and optimal kiloelectron-volt (keV) levels for lung cancer. METHODS: Fifty-nine lung cancer patients underwent chest DECT. Images were reconstructed as VMI series at energy levels of 40, 60, 80, and 100 keV and standard linear blending (M_0.3) for comparison. Objective and subjective image qualities were assessed. RESULTS: Lesion contrast peaked in 40-keV VMI reconstructions (2.5 ± 2.9) and 60 keV (1.9 ± 3.0), which was superior to M_0.3 (0.5 ± 2.7) for both comparisons (P < 0.001). Compared with M_0.3, subjective ratings were highest for 60-keV VMI series regarding general image quality (4.48 vs 4.52; P = 0.74) and increased for lesion demarcation (4.07 vs 4.84; P < 0.001), superior to all other VMI series (P < 0.001). Image sharpness was similar between both series. Image noise was rated superior in the 80-keV and M_0.3 series, followed by 60 keV. CONCLUSIONS: Virtual monoenergetic imaging reconstructions at 60-keV provided the best combination of subjective and objective image qualities in DECT of lung cancer.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Imageamento Tridimensional , Iopamidol/análogos & derivados , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído
2.
Eur Radiol ; 25(6): 1714-20, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25481639

RESUMO

OBJECTIVES: To evaluate quantitative dual-energy computed tomography (DECT) for phantomless analysis of cancellous bone mineral density (BMD) of vertebral pedicles and to assess the correlation with pedicle screw pull-out strength. METHODS: Twenty-nine thoracic and lumbar vertebrae from cadaver specimens were examined with DECT. Using dedicated post-processing software, a pedicle screw vector was mapped (R1, intrapedicular segment of the pedicle vector; R2, intermediate segment; R3, intracorporal segment; global, all segments) and BMD was calculated. To invasively evaluate pedicle stability, pedicle screws were drilled through both pedicles and left pedicle screw pull-out strength was measured. Resulting values were correlated using the paired t test and Pearson's linear correlation. RESULTS: Average pedicle screw vector BMD (R1, 0.232 g/cm(3); R2, 0.166 g/cm(3); R3, 0.173 g/cm(3); global, 0.236 g/cm(3)) showed significant differences between R1-R2 (P < 0.002) and R1-R3 (P < 0.034) segments while comparison of R2-R3 did not reach significance (P > 0.668). Average screw pull-out strength (639.2 N) showed a far stronger correlation with R1 (r = 0.80; P < 0.0001) than global BMD (r = 0.42; P = 0.025), R2 (r = 0.37; P = 0.048) and R3 (r = -0.33; P = 0.078) segments. CONCLUSIONS: Quantitative DECT allows for phantomless BMD assessment of the vertebral pedicle. BMD of the intrapedicular segment shows a significantly stronger correlation with pedicle screw pull-out strength than other segments. KEY POINTS: • Quantitative dual-energy CT enables evaluation of pedicle bone mineral density. • Intrapedicular segments show significant differences regarding bone mineral density. • Pedicle screw pull-out strength correlated strongest with R1 values. • Dual-energy CT may improve preoperative assessment before transpedicular screw fixation.


Assuntos
Densidade Óssea/fisiologia , Vértebras Lombares/fisiologia , Parafusos Pediculares , Vértebras Torácicas/fisiologia , Absorciometria de Fóton/métodos , Idoso , Fenômenos Biomecânicos , Cadáver , Estudos de Casos e Controles , Remoção de Dispositivo , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Vértebras Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
3.
Eur Radiol ; 25(8): 2493-501, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25680727

RESUMO

OBJECTIVES: To define optimal keV settings for advanced monoenergetic (Mono+) dual-energy computed tomography (DECT) in patients with head and neck squamous cell carcinoma (SCC). METHODS: DECT data of 44 patients (34 men, mean age 55.5 ± 16.0 years) with histopathologically confirmed SCC were reconstructed as 40, 55, 70 keV Mono + and M_0.3 (30 % 80 kV) linearly blended series. Attenuation of tumour, sternocleidomastoid muscle, internal jugular vein, submandibular gland, and noise were measured. Three radiologists with >3 years of experience subjectively assessed image quality, lesion delineation, image sharpness, and noise. RESULTS: The highest lesion attenuation was shown for 40 keV series (248.1 ± 94.1 HU), followed by 55 keV (150.2 ± 55.5 HU; P = 0.001). Contrast-to-noise ratio (CNR) at 40 keV (19.09 ± 13.84) was significantly superior to all other reconstructions (55 keV, 10.25 ± 9.11; 70 keV, 7.68 ± 6.31; M_0.3, 5.49 ± 3.28; all P < 0.005). Subjective image quality was highest for 55 keV images (4.53; κ = 0.38, P = 0.003), followed by 40 keV (4.14; κ = 0.43, P < 0.001) and 70 keV reconstructions (4.06; κ = 0.32, P = 0.005), all superior (P < 0.004) to linear blending M_0.3 (3.81; κ = 0.280, P = 0.056). CONCLUSIONS: Mono + DECT at low keV levels significantly improves CNR and subjective image quality in patients with head and neck SCC, as tumour CNR peaks at 40 keV, and 55 keV images are preferred by observers. KEY POINTS: • Mono + DECT combines increased contrast with reduced image noise, unlike linearly blended images. • Mono + DECT imaging allows for superior CNR and subjective image quality. • Head and neck tumour contrast-to-noise ratio peaks at 40 keV. • 55 keV images are preferred over all other series by observers.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos
4.
Neuroradiology ; 57(6): 645-51, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25808122

RESUMO

INTRODUCTION: To investigate low-tube-voltage 80-kVp computed tomography (CT) of head and neck primary and recurrent squamous cell carcinoma (SCC) regarding objective and subjective image quality. METHODS: We retrospectively evaluated 65 patients (47 male, 18 female; mean age: 62.1 years) who underwent head and neck dual-energy CT (DECT) due to biopsy-proven primary (n = 50) or recurrent (n = 15) SCC. Eighty peak kilovoltage and standard blended 120-kVp images were compared. Attenuation and noise of malignancy and various soft tissue structures were measured. Tumor signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Subjective image quality was rated by three reviewers using 5-point grading scales regarding overall image quality, lesion delineation, image sharpness, and image noise. Radiation dose was assessed as CT dose index volume (CTDIvol). Interobserver agreement was calculated using intraclass correlation coefficient (ICC). RESULTS: Mean tumor attenuation (153.8 Hounsfield unit (HU) vs. 97.1 HU), SNR (10.7 vs. 8.3), CNR (8.1 vs. 4.8), and subjective tumor delineation (score, 4.46 vs. 4.13) were significantly increased (all P < 0.001) with 80-kVp acquisition compared to standard blended 120-kVp images. Noise of all measured structures was increased in 80-kVp acquisition (P < 0.001). Overall interobserver agreement was good (ICC, 0.86; 95 % confidence intervals: 0.82-0.89). CTDIvol was reduced by 48.7 % with 80-kVp acquisition compared to standard DECT (4.85 ± 0.51 vs. 9.94 ± 0.81 mGy cm, P < 0.001). CONCLUSIONS: Head and neck CT with low-tube-voltage 80-kVp acquisition provides increased tumor delineation, SNR, and CNR for CT imaging of primary and recurrent SCC compared to standard 120-kVp acquisition with an accompanying significant reduction of radiation exposure.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Doses de Radiação , Estudos Retrospectivos , Razão Sinal-Ruído , Adulto Jovem
5.
Radiol Med ; 120(7): 595-602, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25644250

RESUMO

PURPOSE: This study was done to investigate the dynamic changes of the aortic root during systole and diastole in patients with coronary artery calcification (CAC) using dual-source computed tomography (DSCT). MATERIALS AND METHODS: We retrospectively analysed 77 consecutive patients who underwent calcium-scoring and angiographic cardiac DSCT. The long- and short-axis dimensions, axis areas of the aortic annulus, sinotubular junction and ascending aorta at the level of the pulmonary trunk in diastole and systole were measured. Average dimensions and relative areal changes between diastole and systole (%RA) of aortic annulus, sinotubular junction and ascending aorta were compared. RESULTS: Systolic and diastolic long- and short-axis dimensions of the aortic annulus in patients with CAC (n = 44) demonstrated statistically significant differences (27.00 ± 2.84 mm vs. 28.04 ± 2.62 mm; P < 0.001; 21.78 ± 2.55 mm vs. 20.88 ± 2.31 mm; P < 0.001), while differences in average diameters and areas of the aortic annulus were nonsignificant (P > 0.586). Systolic and diastolic axial areas of the sinotubular junction in patients with CAC demonstrated significant differences (7.21 ± 1.80 cm(2) vs. 6.92 ± 1.75 cm(2); P < 0.001). The %RA of the ascending aorta in patients with severe CAC (CAC score >400; n = 15) was significantly reduced compared to patients with minimal-to-moderate CAC (CAC score <400; n = 29; 4.77 ± 2.88 vs. 7.51 ± 3.81, P = 0.014). CONCLUSIONS: In comparison with patients without CAC, the long- and short-axis dimensions of the aortic annulus and areas of the sinotubular junction show significant differences during the cardiac cycle in patients with CAC. The presence of severe CAC significantly influences the flexibility of the wall of the ascending aorta.


Assuntos
Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Diástole , Sístole , Tomografia Computadorizada por Raios X , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
6.
Radiol Med ; 120(12): 1112-21, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25981379

RESUMO

OBJECTIVES: To compare radiation exposure and image quality of second-generation 128-slice dual-source CT (DSCT) coronary angiography (cCTA) protocols. MATERIALS AND METHODS: We retrospectively analyzed data from four groups with 25 patients, each examined by one of the following DSCT cCTA protocols: prospectively ECG-gated high-pitch (group 1) or sequential (group 2) acquisition, retrospectively ECG-gated acquisition in dual-energy (DECT, group 3) or dual-source (group 4) mode. CT dose index volume, dose length product, estimated radiation dose, contrast-to-noise- and signal-to-noise-ratios were compared. Subjective image quality was rated by two observers blinded to the protocols. RESULTS: High-pitch DSCT showed a mean estimated radiation dose of 1.27 ± 0.62 mSv, significantly (p < 0.01) lower than sequential (2.04 ± 0.94 mSv), dual-energy (3.97 ± 1.29 mSv) or dual-source (8.11 ± 4.95 mSv) acquisition. Image noise showed no statistical difference (p > 0.91), ranging from 15.2 ± 4.4 (group 2) up to 24.5 ± 22.0 (group 4). Each protocol showed diagnostic image quality in at least 98.1 % of evaluated coronary segments without significant differences (p > 0.05). CONCLUSIONS: Prospectively ECG-gated DSCT protocols enable cCTA with significant dose reduction and consistently diagnostic image quality. In patients requiring retrospectively ECG-gated DSCT for functional analysis or due to arrhythmia, dual-energy mode should be preferred over dual-source mode as it significantly decreases estimated dose without compromising image quality.


Assuntos
Angiografia Coronária/métodos , Aumento da Imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Idoso , Humanos , Estudos Retrospectivos
7.
Radiology ; 271(3): 778-84, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24475863

RESUMO

PURPOSE: To evaluate the feasibility of phantomless in vivo dual-energy computed tomography (CT)-based three-dimensional (3D) bone mineral density (BMD) assessment in comparison with dual x-ray absorptiometry (DXA). MATERIALS AND METHODS: This retrospective study was approved by the institutional review board, and the requirement to obtain informed consent was waived. Data from clinically indicated dual-energy CT and DXA examinations within 2 months, comprising the lumbar spine of 40 patients, were included. By using automated dedicated postprocessing dual-energy CT software, the trabecular bone of lumbar vertebrae L1-L4 were analyzed and segmented. A mixed-effects model was used to assess the correlations between BMD values derived from dual-energy CT and DXA. RESULTS: One hundred sixty lumbar vertebrae were analyzed in 40 patients (mean age, 57.1 years; range, 24-85 years), 21 male (mean age, 54.3 years; range, 24-85 years) and 19 female (mean age, 58.5 years; range, 31-80 years). Mean BMD of L1-L4 determined with DXA was 0.995 g/cm(2), and 18 patients (45%) showed an osteoporotic BMD (T score less than -2.5) of at least two vertebrae. Mean dual-energy CT-based BMD of L1-L4 was 0.254 g/cm(3). Bland-Altman analysis with mixed effects demonstrated a lack of correlation between dual-energy CT-based and DXA-based BMD values, with a mean difference of 0.7441 and 95% limits of agreement of 0.7441 ± 0.4080. CONCLUSION: Dedicated postprocessing of dual-energy CT data allows for phantomless in vivo BMD assessment of the trabecular bone of lumbar vertebrae and enables freely rotatable color-coded 3D visualization of intravertebral BMD distribution.


Assuntos
Densidade Óssea , Doenças Ósseas Metabólicas/diagnóstico por imagem , Imageamento Tridimensional , Vértebras Lombares/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Absorciometria de Fóton , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Ósseas Metabólicas/patologia , Feminino , Humanos , Vértebras Lombares/patologia , Masculino , Pessoa de Meia-Idade , Osteoporose/patologia , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
8.
Eur Radiol ; 24(6): 1211-8, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24599623

RESUMO

OBJECTIVES: To evaluate image quality and diagnostic accuracy of selective monoenergetic reconstructions of late iodine enhancement (LIE) dual-energy computed tomography (DECT) for imaging of chronic myocardial infarction (CMI). METHODS: Twenty patients with a history of coronary bypass surgery underwent cardiac LIE-DECT and late gadolinium enhancement (LGE) magnetic resonance imaging (MRI). LIE-DECT images were reconstructed as selective monoenergetic spectral images with photon energies of 40, 60, 80, and 100 keV and the standard linear blending setting (M_0.6). Images were assessed for late enhancement, transmural extent, signal characteristics and subjective image quality. RESULTS: Seventy-nine myocardial segments (23 %) showed LGE. LIE-DECT detected 76 lesions. Images obtained at 80 keV and M_0.6 showed a high signal-to-noise ratio (15.9; 15.1), contrast-to-noise ratio (4.2; 4.0) and sensitivity (94.9 %; 92.4 %) while specificity was identical (99.6 %). Differences between these series were not statistically significant. Transmural extent of LIE was overestimated in both series (80 keV: 40 %; M_0.6: 35 %) in comparison to MRI. However, observers preferred 80 keV in 13/20 cases (65 %, κ = 0.634) over M_0.6 (4/20 cases) regarding subjective image quality. CONCLUSIONS: Post-processing of LIE-DECT data with selective monoenergetic reconstructions at 80 keV significantly improves subjective image quality while objective image quality shows no significant difference compared to standard linear blending. KEY POINTS: Late enhancement dual-energy CT allows for detection of chronic myocardial infarction. Monoenergetic reconstructions at 80 keV significantly improve subjective image quality. 80 keV and standard linear blending reconstructions show no significant differences. Extent of CMI detected with LIE-DECT is overestimated compared with MRI.


Assuntos
Aumento da Imagem/métodos , Iodo , Infarto do Miocárdio/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Doença Crônica , Meios de Contraste , Ponte de Artéria Coronária , Feminino , Gadolínio , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/cirurgia , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído
9.
Eur Radiol ; 24(3): 574-80, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24081649

RESUMO

OBJECTIVES: To evaluate whether dual-energy computed tomography (DECT)-derived iodine content and iodine overlay could differentiate between normal, inflammatory and metastatic squamous cell carcinoma (SCC) cervical lymph nodes. METHODS: This study was approved by the institutional review board. Sixteen patients with normal lymph nodes, 20 patients with enlarged nodes draining deep cervical inflammations and 23 patients with pathologically proved metastatic SCC nodes who underwent contrast enhanced DECT were retrospectively identified. Iodine content and overlay of 36 normal, 43 inflammatory and 52 metastatic lymph nodes were calculated using circular regions of interest and compared among the three groups. A receiver operating characteristic (ROC) curve was used to determine the sensitivity and specificity of iodine content and overlay for diagnosis of metastatic nodes. RESULTS: Iodine content (mg/ml) was significantly lower for metastatic lymph nodes (2.34 ± 0.45) than for normal (2.86 ± 0.37) and inflammatory (3.53 ± 0.56) lymph nodes, P < 0.0001. Iodine overlay (HU) was also significantly lower for metastatic lymph nodes (47 ± 11.6) than normal (57.4 ± 8.2) and inflammatory nodes (69.3 ± 11.5), P < 0.0001. The areas under the ROC curve for iodine content and iodine overlay were 0.923 and 0.896. CONCLUSIONS: DECT-derived iodine content and overlay differ significantly among normal, inflammatory and metastatic SCC cervical lymph nodes. KEY POINTS: • Derived iodine content can be calculated from contrast-enhanced dual-energy CT. • Derived iodine content and iodine overlay could help characterise cervical lymph nodes. • Iodine parameters were significantly lower in metastatic lymph nodes than normal/inflammatory lymph nodes. • Iodine content appears more sensitive than iodine overlay for lymph node characterisation.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Iodo/metabolismo , Linfadenite/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Escamosas/metabolismo , Carcinoma de Células Escamosas/secundário , Feminino , Neoplasias de Cabeça e Pescoço/metabolismo , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/metabolismo , Linfadenite/metabolismo , Linfadenite/patologia , Metástase Linfática/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Pescoço/patologia , Variações Dependentes do Observador , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adulto Jovem
10.
Eur Radiol ; 24(7): 1725-34, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24816940

RESUMO

OBJECTIVE: To investigate the impact of automated attenuation-based tube potential selection on image quality and exposure parameters in polytrauma patients undergoing contrast-enhanced thoraco-abdominal CT. METHODS: One hundred patients were examined on a 16-slice device at 120 kV with 190 ref.mAs and automated mA modulation only. Another 100 patients underwent 128-slice CT with automated mA modulation and topogram-based automated tube potential selection (autokV) at 100, 120 or 140 kV. Volume CT dose index (CTDI(vol)), dose-length product (DLP), body diameters, noise, signal-to-noise ratio (SNR) and subjective image quality were compared. RESULTS: In the autokV group, 100 kV was automatically selected in 82 patients, 120 kV in 12 patients and 140 kV in 6 patients. Patient diameters increased with higher kV settings. The median CTDI(vol) (8.3 vs. 12.4 mGy; -33%) and DLP (594 vs. 909 mGy cm; -35%) in the entire autokV group were significantly lower than in the group with fixed 120 kV (p < 0.05 for both). Image quality remained at a constantly high level at any selected kV level. CONCLUSION: Topogram-based automated selection of the tube potential allows for significant dose savings in thoraco-abdominal trauma CT while image quality remains at a constantly high level. KEY POINTS: • Automated kV selection in thoraco-abdominal trauma CT results in significant dose savings • Most patients benefit from a 100-kV protocol with relevant DLP reduction • Constantly good image quality is ensured • Image quality benefits from higher kV when arms are positioned downward.


Assuntos
Traumatismos Abdominais/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada Multidetectores/instrumentação , Traumatismo Múltiplo/diagnóstico por imagem , Traumatismos Torácicos/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
11.
Eur Radiol ; 24(11): 2927-35, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25030462

RESUMO

OBJECTIVES: To intra-individually compare single-portal-phase low-tube-voltage (100-kVp) computed tomography (CT) with 120-kVp images for short-term follow-up assessment of CT severity index (CTSI) of acute pancreatitis, interobserver agreement and radiation dose. METHODS: We retrospectively analysed 66 patients with acute pancreatitis who underwent initial dual-contrast-phase CT (unenhanced, arterial, portal phase) at admission and short-term (mean interval 11.4 days) follow-up dual-contrast-phase dual-energy CT. The 100-kVp and linearly blended images representing 120-kVp acquisition follow-up CT images were independently evaluated by three radiologists using a modified CTSI assessing pancreatic inflammation, necrosis and extrapancreatic complications. Scores were compared with paired t test and interobserver agreement was evaluated using intraclass correlation coefficients (ICC). RESULTS: Mean CTSI scores on unenhanced, portal- and dual-contrast-phase images were 4.9, 6.1 and 6.2 (120 kVp) and 5.0, 6.0 and 6.1 (100 kVp), respectively. Contrast-enhanced series showed a higher CTSI compared to unenhanced images (P < 0.05) but no significant differences between single- and dual-contrast-phase series (P > 0.7). CTSI scores were comparable for 100-kVp and 120-kVp images (P > 0.05). Interobserver agreement was substantial for all evaluated series and subcategories (ICC 0.67-0.93). DLP of single-portal-phase 100-kVp images was reduced by 41 % compared to 120-kVp images (363.8 versus 615.9 mGy cm). CONCLUSIONS: Low-tube-voltage single-phase 100-kVp CT provides sufficient information for follow-up evaluation of acute pancreatitis and significantly reduces radiation exposure. KEY POINTS: • Single-portal-phase CT provides sufficient evaluation for follow-up of acute pancreatitis. • Follow-up CT does not benefit from unenhanced or arterial-phase acquisition. • CT severity index scores are equal for dual-contrast-phase 100-/120-kVp acquisition (P > 0.05). • 100-kVp single-portal-phase follow-up CT of acute pancreatitis significantly reduces radiation exposure.


Assuntos
Tomografia Computadorizada Multidetectores/métodos , Pancreatite Necrosante Aguda/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Doses de Radiação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Adulto Jovem
12.
Radiology ; 260(2): 390-9, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21693660

RESUMO

PURPOSE: To prospectively compare traditional filtered back projection (FBP) and iterative image reconstruction for the evaluation of heavily calcified arteries with coronary computed tomography (CT) angiography. MATERIALS AND METHODS: The study had institutional review board approval and was HIPAA compliant. Written informed consent was obtained from all patients. Fifty-five consecutive patients (35 men, 20 women; mean age, 58 years ± 12 [standard deviation]) with Agatston scores of at least 400 underwent coronary CT angiography and cardiac catheterization. Image data were reconstructed with both FBP and iterative reconstruction techniques with corresponding cardiac algorithms. Image noise and subjective image quality were compared. To objectively assess the effect of FBP and iterative reconstruction on blooming artifacts, volumes of circumscribed calcifications were measured with dedicated volume analysis software. FBP and iterative reconstruction series were independently evaluated for coronary artery stenosis greater than 50%, and their diagnostic accuracy was compared, with cardiac catheterization as the reference standard. Statistical analyses included paired t tests, Kruskal-Wallis analysis of variance, and a modified McNemar test. RESULTS: Image noise measured significantly lower (P = .011-.035) with iterative reconstruction instead of FBP. Image quality was rated significantly higher (P = .031 and .042) with iterative reconstruction series than with FBP. Calcification volumes measured significantly lower (P = .019 and .026) with iterative reconstruction (44.3 mm(3) ± 64.7 and 46.2 mm(3) ± 68.8) than with FBP (54.5 mm(3) ± 69.5 and 56.3 mm(3) ± 72.5). Iterative reconstruction significantly improved some measures of per-segment diagnostic accuracy of coronary CT angiography for the detection of significant stenosis compared with FBP (accuracy: 95.9% vs 91.8%, P = .0001; specificity: 95.8% vs 91.2%, P = .0001; positive predictive value: 76.9% vs 61.1%, P = .0001). CONCLUSION: Iterative reconstruction reduces image noise and blooming artifacts from calcifications, leading to improved diagnostic accuracy of coronary CT angiography in patients with heavily calcified coronary arteries.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Análise de Variância , Artefatos , Distribuição de Qui-Quadrado , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
13.
Eur Radiol ; 21(9): 1895-903, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21533864

RESUMO

OBJECTIVE: To prospectively compare the accuracy of coronary CT angiography (CCTA) and conventional coronary angiography (CCA) for stenosis detection using composite findings from both tests as an enhanced reference standard. METHODS: One hundred thirteen patients underwent CCTA and CCA. Per-segment and per-patient accuracy of CCTA compared with initial CCA interpretation were determined. Angiographers were then unblinded to the CCTA results and re-evaluation of the CCA studies was performed with knowledge of CCTA findings, which was used as an enhanced reference standard to compare the diagnostic accuracy of CCTA versus CCA. RESULTS: When using the enhanced reference standard instead of initial CCA interpretation, CCTA accuracy for identifying segments (patients) with ≥50% stenosis increased from 97.7% (96.5%) to 98.1% (98.2%), sensitivity from 90.5% (100%) to 90.8% (100%), and specificity from 98.4% (94.3%) to 98.9% (97.1%). CCTA identified six segments and two patients with stenoses ≥50% missed on initial CCA interpretation. Compared with the enhanced reference standard the accuracies of CCTA and of initial CCA interpretation were not different (p = 0.87). CONCLUSION: CCTA compares favourably with CCA for stenosis detection. Use of a composite reference standard combining findings from both tests can control for the effect of false-negative CCA results when evaluating the accuracy of CCTA.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Meios de Contraste , Estenose Coronária/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Padrões de Referência , Sensibilidade e Especificidade , Índice de Gravidade de Doença
14.
Eur Radiol ; 21(1): 107-12, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20644936

RESUMO

OBJECTIVE: Computed tomography (CT) of the paranasal sinus is the standard diagnostic tool for a wide range of indications in mostly younger patients. This study aims to assess the image quality of CT of the sinus by using a high-pitch dual-source technique with special regard to the radiation dose. METHODS: Examinations were performed on a second-generation dual-source CT with a pitch factor of 3.0 (dual-source mode). Images were compared with those with a pitch factor of 0.9 on the same system (single-source mode) and with those of 16-slice CT. Image quality was evaluated by four blinded readers using a 5-point scale (1=poor, 5=excellent). Comparison of the dose length product (DLP) was used to estimate radiation exposure. RESULTS: Seventy-three consecutive patients underwent imaging with the proposed CT protocols. The viewers rated the image quality of the dual-source image sets as nearly as good (3.62) as the single-source images on the same device (4.18) and those on 16-slice CT (3.7). DLP was cut to half of the dose [51 mGycm vs. 97.8 mGycm vs. 116.9 mGycm (p<0.01)]. CONCLUSIONS: Using the proposed dual-source mode when examining the paranasal sinus, diagnostic image quality can be achieved while drastically lowering the patient's radiation exposure.


Assuntos
Seios Paranasais/diagnóstico por imagem , Crânio/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Humanos , Pessoa de Meia-Idade , Monitoramento de Radiação
15.
Eur Radiol ; 21(3): 530-7, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20862476

RESUMO

PURPOSE: To compare the dose estimates and image quality of Dual Energy CT (DECT), Dual Source CT (DSCT) and 16-slice CT for coronary CT angiography (cCTA). METHODS: Sixty-eight patients were examined with 16 - slice MDCT (group 1), 68 patients with DSCT (group 2) and 68 patients using DSCT in dual energy mode (DECT group 3). CT dose index volume, dose length product, effective dose, signal-to-noise, and contrast-to-noise ratio were compared. Subjective image quality was rated by two observers, blinded to technique. RESULTS: The mean estimated radiation dose of all patients investigated on a 16 - slice MDCT was 12 ± 3.59 mSv, for DSCT in single energy 9.8 ± 4.77 mSv and for DECT 4.54 ± 1.87 mSv. Dose for CTA was significantly lower in group 3 compared to group 1 and 2. The image noise was significantly lower in Group 2 in comparison to group 1 and group 3. There was no significant difference in diagnostic image quality comparing DECT and DSCT. CONCLUSION: cCTA shows better dose levels at both DECT and DSCT compared to 16-slice CT. Further, DECT delivers significantly less dose than regular DSCT or single source single energy cCTA while maintaining diagnostic image quality.


Assuntos
Carga Corporal (Radioterapia) , Angiografia Coronária/métodos , Doses de Radiação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Eur Radiol ; 21(9): 1914-21, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21533631

RESUMO

OBJECTIVE: To investigate the role of perfusion defect (PD) size on dual energy CT pulmonary blood volume assessment as predictor of right heart strain and patient outcome and its correlation with d-dimer levels in acute pulmonary embolism (PE). METHODS: 53 patients with acute PE who underwent DECT pulmonary angiography were retrospectively analyzed. Pulmonary PD size caused by PE was measured on DE iodine maps and quantified absolutely (VolPD) and relatively to the total lung volume (RelPD). Signs of right heart strain (RHS) on CT were determined. Information on d-dimer levels and readmission for recurrent onset of PE and death was collected. RESULTS: D-dimer level was mildly (r = 0.43-0.47) correlated with PD size. Patients with RHS had significantly higher VolPD (215 vs. 73 ml) and RelPD (9.9 vs. 2.9%) than patients without RHS (p < 0.003). There were 2 deaths and 1 readmission due of PE in 18 patients with >5% RelPD, while no such events were found for patients with <5% RelPD. CONCLUSION: Pulmonary blood volume on DECT in acute PE correlates with RHS and appears to be a predictor of patient outcome in this pilot study.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Produtos de Degradação da Fibrina e do Fibrinogênio/metabolismo , Pulmão/irrigação sanguínea , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/mortalidade , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Função do Átrio Esquerdo/fisiologia , Biomarcadores/sangue , Estudos de Casos e Controles , Estudos de Coortes , Intervalos de Confiança , Feminino , Testes de Função Cardíaca , Humanos , Estimativa de Kaplan-Meier , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Circulação Pulmonar/fisiologia , Embolia Pulmonar/sangue , Estudos Retrospectivos , Índice de Gravidade de Doença , Análise de Sobrevida , Função Ventricular Direita/fisiologia
17.
AJR Am J Roentgenol ; 196(6): 1374-80, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21606302

RESUMO

OBJECTIVE: The purpose of this study is to evaluate the effect of arterial input selection on perfusion CT parameters of head and neck tumors. MATERIALS AND METHODS: Perfusion calculations were done for 50 cases using deconvolution-based software. Peak enhancement values of the ipsilateral internal carotid artery (ICA) and external carotid artery (ECA) were recorded. Blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability surface area product were calculated using ipsilateral ECA, ipsilateral ICA, and contralateral ICA as input arteries. Values were compared using Wilcoxon's matched pair test and Pearson's correlation coefficients (r). RESULTS: A highly significant correlation was observed between peak enhancement values of the ICA and ECA (r = 0.97; p < 0.0001). A high correlation was observed between perfusion calculations obtained using ipsilateral ICA and ECA (BF, r = 0.98; BV, r = 0.92; MTT, r = 0.91; and permeability surface area product, r = 0.89), ipsilateral and contralateral ICA (BF, r = 0.97; BV, r = 0.95; MTT, r = 0.93; and permeability surface area product, r = 0.89), as well as left and right ICA (BF, r = 0.97; BV, r = 0.95; MTT, r = 0.94; and permeability surface area product, r = 0.88). All correlations were statistically significant (p < 0.0001). No significant differences were observed between perfusion calculations obtained using ipsilateral ICA versus ECA, ipsilateral versus contralateral ICA, or left versus right ICA (p > 0.05). CONCLUSION: Arterial input selection has no significant effect on perfusion CT calculation of head and neck cancer. For standardization and simplification of postprocessing, we recommend the use of the ICA instead of the ECA as the arterial input because of its better visualization, perpendicular course, and larger caliber, all of which decrease partial volume effects.


Assuntos
Artéria Carótida Externa/diagnóstico por imagem , Artéria Carótida Interna/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Feminino , Neoplasias de Cabeça e Pescoço/irrigação sanguínea , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Software , Estatísticas não Paramétricas
18.
AJR Am J Roentgenol ; 197(6): 1399-403, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22109295

RESUMO

OBJECTIVE: The purpose of this article is to determine the degree to which the skin entrance dose could be lowered, by adjusting exposure parameters and filtration, and the subsequent effect on readers' confidence levels of digital radiographs. MATERIALS AND METHODS: The study was prospectively performed on a cadaver. Digital radiographs of bones were evaluated and scored on a 9-point scale separately by four radiologists who were blinded to the types of filtration and doses used. The study entailed three phases: phase 1, random dose and filter; phase 2, fixed filter and varying radiation doses (100%, 75%, 50%, and 25% of the standard recommended dose); and phase 3, fixed dose and varying filtration (no filtration, aluminum filter, and aluminum-copper filter). Skin entrance dose was measured using a dosimeter placed on the skin. Differences in scores were tested using a Friedman test. RESULTS: The mean scores given to images with 100%, 75%, 50%, and 25% of the recommended standard dose were 6.18, 6.1, 5.11, and 4.07, respectively. No significant difference was noted between 100%- and 75%-dose images (p = 0.1). A significant difference (p < 0.0001) was noted when we compared the 100%- and 75%-dose images with the 50%- and 25%-dose images. The mean scores given for no filtration, aluminum filtration, and aluminum-copper filtration were 5.67, 5.43, and 5.18, respectively. No significant difference between no filtration and aluminum filtration (p = 0.411) was noted. A significant difference was detected between no filtration and aluminum-copper filtration (p = 0.012). The combination of an aluminum filter and a 75% standard dose achieved a 31.1% reduction in skin entrance dose. CONCLUSION: It is possible to achieve a 31.1% reduction in skin entrance dose for imaging bony structures by using 75% of the standard dose and aluminum filtration without significantly affecting image quality.


Assuntos
Osso e Ossos/diagnóstico por imagem , Doses de Radiação , Intensificação de Imagem Radiográfica/instrumentação , Pele/efeitos da radiação , Alumínio , Cadáver , Cobre , Filtração/instrumentação , Humanos , Masculino , Estudos Prospectivos , Radiometria
19.
Acta Radiol ; 52(8): 834-9, 2011 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-21873508

RESUMO

BACKGROUND: Detection of myocardial infarction has been the focus of considerable research over the past few decades. Recently developed dual source computed tomography (DSCT) scanners with dual energy mode have been used to detect myocardial infarction, but the studies on this topic are few. PURPOSE: To evaluate the feasibility and performance of dual energy CT (DECT) during arterial phase in coronary CT angiography for the detection of chronic infarction compared with late enhancement MRI (LE-MRI) and histopathology in a porcine model of reperfused myocardial infarction. MATERIAL AND METHODS: Myocardial infarctions were induced by 30 min occlusion of the proximal left anterior descending coronary artery in eight minipigs. DECT, post-contrast LE-MRI and histopathology were performed 60 days after infarct induction. The CT scan was performed in dual energy mode using a dedicated protocol. Myocardial iodine distribution was superimposed as color maps on grey scale multiplanar reformats of the heart. Two radiologists in consensus interpreted all imaging studies for presence of gadolinium uptake at LE-MRI reduced iodine content at DECT and hypoenhanced areas in the initial 100 kV coronary CT angiography images that were acquired during the DECT-acquisition. Results were compared with histopathology. RESULTS: Based on evaluable segments, DECT showed a sensitivity and specificity of 0.72 and 0.88; LE-MRI showed a sensitivity and specificity of 0.78 and 0.92; and the 100 kV data-set of the DECT scan showed a sensitivity and specificity of 0.60 and 0.93, respectively, for the detection of histological proved ischemia. CONCLUSION: DECT during arterial phase coronary CT angiography, which is ordinarily used for coronary artery evaluation, is feasible for the detection of a chronic reperfused myocardial infarction.


Assuntos
Infarto do Miocárdio/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Animais , Doença Crônica , Meios de Contraste , Modelos Animais de Doenças , Estudos de Viabilidade , Imageamento por Ressonância Magnética , Infarto do Miocárdio/patologia , Reperfusão Miocárdica , Sensibilidade e Especificidade , Suínos , Porco Miniatura
20.
AJR Am J Roentgenol ; 195(3): 639-46, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20729440

RESUMO

OBJECTIVE: The purpose of this article is to compare the performance of dual-energy CT with that of 3-T MRI with late enhancement for the detection of chronic myocardial infarction during first-pass coronary CT angiography (CTA). SUBJECTS AND METHODS: Thirty-six patients underwent coronary CTA for the assessment of coronary bypass graft patency on a first-generation dual-source CT scanner in dual-energy mode. Gray-scale images (100 kV, 140 kV, and blended virtual 120 kV) were assessed for areas of hypodense myocardium during the arterial phase. In addition, a color-coded map of myocardial iodine distribution was calculated from the dual-energy data for perfusion analysis. Dual-energy CT data were compared with data from 3-T MRI with late enhancement, which served as the reference standard for scar detection using the American Heart Association's 17-segment model of the left ventricle. RESULTS: One hundred one (17%) of 612 myocardial segments in 22 (61%) of 36 patients showed late enhancement on MRI. Although myocardial iodine mapping was prone to artifacts, mostly arising from sternal wires (70% sensitivity), 100-kV gray-scale images showed the highest sensitivity (80%) for the detection of myocardial scar. Blended virtual 120-kV images with lower noise and higher resolution had the best diagnostic accuracy (77% sensitivity, 97% specificity, 85% positive predictive value, 96% negative predictive value, and 94% accuracy). CONCLUSION: Detection of chronic myocardial infarction on color-coded iodine distribution analysis with first-generation dual-energy CT is impeded by thoracic metallic devices. This group of patients benefits more from adequate blending of high- and low-kilovoltage gray-scale images. Further technical improvements are desirable to lower artifact burden and improve sensitivity on myocardial iodine distribution mapping.


Assuntos
Doença das Coronárias/patologia , Infarto do Miocárdio/patologia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Artefatos , Doença Crônica , Meios de Contraste , Angiografia Coronária , Ponte de Artéria Coronária , Doença das Coronárias/diagnóstico por imagem , Eletrocardiografia , Feminino , Gadolínio , Compostos Heterocíclicos , Humanos , Interpretação de Imagem Assistida por Computador , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/cirurgia , Compostos Organometálicos , Valor Preditivo dos Testes , Sensibilidade e Especificidade