Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Anal Chem ; 2023 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-36634199

RESUMO

Mass spectrometry imaging (MSI) has been widely used to discover natural products (NPs) from underexplored microbiological sources. However, the technique is limited by incompatibility with complicated/uneven surface topography and labor-intensive sample preparation, as well as lengthy compound profiling procedures. Here, liquid micro-junction surface sampling probe (LMJ-SSP)-based MSI is used for rapid profiling of natural products from Gram-negative marine bacteria Pseudoalteromonas on nutrient agar media without any sample preparation. A conductance-based autosampling platform with 1 mm spatial resolution and an innovative multivariant analysis-driven method was used to create one hyperspectral image for the sampling area. NP discovery requires general spatial correlation between m/z and colony location but not highly precise spatial resolution. The hyperspectral image was used to annotate different m/z by straightforward color differences without the need to directly interrogate the spectra. To demonstrate the utility of our approach, the rapid analysis of Pseudoalteromonas rubra DSM6842, Pseudoalteromonas tunicata DSM14096, Pseudoalteromonas piscicida JCM20779, and Pseudoalteromonas elyakovii ATCC700519 cultures was directly performed on Agar. Various natural products, including prodiginine and tambjamine analogues, were quickly identified from the hyperspectral image, and the dynamic extracellular environment was shown with compound heatmaps. Hyperspectral visualization-based MSI is an efficient and sensitive strategy for direct and rapid natural product profiling from different Pseudoalteromonas strains.

2.
J Proteome Res ; 21(10): 2462-2471, 2022 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-36074808

RESUMO

We describe a method to obtain a comprehensive profile of multiple glycosylations in glycopeptide isoforms. We detected a wide range of abundances of various O-glycoforms in isomeric glycopeptides using hot electron capture dissociation (hot ECD) in liquid chromatography-tandem mass spectrometry. To capture low abundant glycosylated species, a prototype of a ZenoTOF 7600 system incorporating an efficient electron-activated dissociation device to perform hot ECD was operated in targeted or scheduled high-resolution multiple reaction monitoring workflows. In addition, Zeno trap pulsing was activated to enhance the sensitivity of the time-of-flight mass spectrometer. Sixty-nine O-glycopeptides of the long O-glycopeptides in tryptic bovine fetuin digest were obtained with a relative abundance range from 100 to 0.2%, which included sialylated glycans with Neu5Ac and Neu5Gc.


Assuntos
Glicopeptídeos , Espectrometria de Massas em Tandem , Animais , Bovinos , Elétrons , Fetuínas , Glicopeptídeos/análise , Polissacarídeos/química , Isoformas de Proteínas , Espectrometria de Massas em Tandem/métodos
3.
Anal Chem ; 94(27): 9519-9524, 2022 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-35767324

RESUMO

Molecular stream separation (MSS) is a promising complement for continuous-flow synthesis. MSS is driven by forces exerted on molecules by a field applied at an angle to the stream-carrying flow. MSS has only been performed with a 90° field-to-flow angle because of a rectangular geometry of canonic MSS; the second-order rotational symmetry of a rectangle prevents any other angle. Here, we propose a noncanonic circular geometry for MSS, which better aligns with the polar nature of MSS and allows changing the field-to-flow. We conducted in silico and experimental studies of circular geometry for continuous-flow electrophoresis (CFE, an MSS method). We proved two advantages of circular CFE over its rectangular counterpart. First, circular CFE can support better flow and electric-field uniformity than rectangular CFE. Second, the nonorthogonal field-to-flow orientation, achievable in circular CFE, can result in a higher stream resolution than the orthogonal one. Considering that circular CFE devices are not more complex in fabrication than rectangular ones, we foresee that circular CFE will serve as a new standard and a testbed for the investigation and creation of new CFE modalities.


Assuntos
Eletricidade , Rios , Eletroforese/métodos , Matemática
4.
Anal Chem ; 94(20): 7219-7228, 2022 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-35537093

RESUMO

We describe a new liquid tissue stamping method called poly-synchronous surface extraction (PSSE) that utilizes an omniphobic substrate patterned with hydrophilic surface energy traps (SETs), which when wet with a solvent form a dense microdroplet array. When contacted with a tissue sample, each droplet locally extracts analytes from the tissue surface, which subsequentially can be analyzed by matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-IMS) or ambient ionization-MS techniques. Optimization of the patterned surface with six different solvents was carried out to increase the droplet density, height, and reproducibility of volume deposition. Once optimized, sister slices of a strawberry (Fragaria × ananassa) were spatially extracted using the PSSE technique and the chemical distribution of selected compounds was analyzed with both MALDI-IMS and a lower resolution but faster ambient liquid microjunction surface sampling probe (LMJ-SSP) approach. Heat maps for target analytes for the PSSE approach are compared to those produced using traditional MALDI-IMS analysis. The PSSE method aligned well with direct analysis and demonstrated the potential to increase the speed of ambient MS tissue imaging techniques by decreasing the number of steps required for sample preparation.


Assuntos
Diagnóstico por Imagem , Interações Hidrofóbicas e Hidrofílicas , Reprodutibilidade dos Testes , Solventes , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
5.
Anal Chem ; 94(44): 15415-15422, 2022 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-36301587

RESUMO

Large molecules can be generically separated from small ones, though partially and temporarily, in a pressure-driven flow inside a capillary. This transient incomplete separation has been only applied to species with diffusion coefficients different by at least an order of magnitude. Here, we demonstrate, for the first time, the analytical utility of transient incomplete separation for species with close diffusion coefficients. First, we prove in silico that even a small difference in diffusivity can lead to detectable transient incomplete separation of species. Second, we use computer simulation to prove that such a separation can be used for the reliable determination of equilibrium dissociation constant (Kd) of complexes composed of similar-sized molecules. Finally, we demonstrate experimentally the use of this separation for the accurate determination of Kd value for a protein-aptamer complex. We conclude that "accurate constant via transient incomplete separation" (ACTIS) can serve as a reference method for affinity characterization of protein-aptamer binding in solution.


Assuntos
Eletroforese Capilar , Oligonucleotídeos , Eletroforese Capilar/métodos , Simulação por Computador , Ligação Proteica , Oligonucleotídeos/química , Entropia
6.
Anal Chem ; 93(34): 11654-11659, 2021 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-34410698

RESUMO

Accurate Constant via Transient Incomplete Separation (ACTIS) is a new method for finding the equilibrium dissociation constant Kd of a protein-small molecule complex based on transient incomplete separation of the complex from the unbound small molecule in a capillary. This separation is caused by differential transverse diffusion of the complex and the small molecule in a pressure-driven flow. The advection-diffusion processes underlying ACTIS can be described by a system of partial differential equations allowing for a virtual ACTIS instrument to be built and ACTIS to be studied in silico. The previous in silico studies show that large variations in the fluidic system geometry do not affect the accuracy of Kd determination, thus, proving that ACTIS is conceptually accurate. The conceptual accuracy does not preclude, however, instrumental inaccuracy caused by run-to-run signal drifts. Here we report on assembling a physical ACTIS instrument with a fluidic system that mimics the virtual one and proving the absence of signal drifts. Furthermore, we confirmed method ruggedness by assembling a second ACTIS instrument and comparing the results of experiments performed with both instruments in parallel. Despite some unintentional differences between the instruments (caused by tolerances in sizes, positions, etc.) and noticeable differences in their respective separagrams, we found that the Kd values determined for identical samples with these instruments were equal. Conclusively, the fluidic system presented here can serve as a template for reliable ACTIS instrumentation.


Assuntos
Entropia
7.
Phys Chem Chem Phys ; 23(36): 20607-20614, 2021 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-34505849

RESUMO

para-Aminobenzoic acid (PABA) was electrosprayed from mixtures of protic and aprotic solvents, leading to formation of two prototropic isomers in the gas phase whose relative populations depended on the composition of the electrospray solvent. The two ion populations were separated in the gas phase using differential mobility spectrometry (DMS) within a nitrogen-only environment at atmospheric pressure. Under high-field conditions, the two prototropic isomers eluted with baseline signal separation with the N-protonated isomer having a more negative CV shift than the O-protonated isomer, in accord with previous DMS studies. The conditions most favorable for formation and separation of each tautomer were used to trap each prototropic isomer in a quadrupole ion trap for photodissociation action spectroscopy experiments. Spectral interrogation of each prototropic isomer in the UV region (3-6 eV) showed good agreement with previously recorded spectra, although a previously reported band (4.8-5.4 eV) was less intense for the O-protonated isomer in our measured spectrum. Without DMS selection, the measured spectra contained features corresponding to both protonated isomers even when solvent conditions were optimised for formation of a single isomer. Interconversion between protonated isomers within the ion trap was observed when protic ESI solvents were employed, leading to spectral cross contamination even with mobility selection. CCSD vertical excitation energies and vertical gradient (VG) Franck-Condon simulations are presented and reproduce the measured spectral features with near-quantitative agreement, providing supporting evidence for spectral assignments.

8.
Phys Chem Chem Phys ; 23(35): 19892-19900, 2021 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-34525152

RESUMO

Two prototropic isomers of adenine are formed in an electrospray ion source and are resolved spatially in a differential mobility spectrometer before detection in a triple quadrupole mass spectrometer. Each isomer is gated in CV space before being trapped in the linear ion trap of the modified mass spectrometer, where they are irradiated by the tuneable output of an optical parametric oscillator and undergo photodissociation to form charged fragments with m/z 119, 109, and 94. The photon-normalised intensity of each fragmentation channel is measured and the action spectra for each DMS-gated tautomer are obtained. Our analysis of the action spectra, aided by calculated vibronic spectra and thermochemical data, allow us to assign the two signals in our measured ionograms to specific tautomers of protonated adenine.


Assuntos
Adenina/química , Espectrofotometria Infravermelho , Isomerismo , Fotólise , Prótons , Termodinâmica , Raios Ultravioleta
9.
J Phys Chem A ; 125(37): 8187-8195, 2021 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-34432451

RESUMO

Two ion populations of protonated Rivaroxaban, [C19H18ClN3O5S + H]+, are separated under pure N2 conditions using differential mobility spectrometry prior to characterization in a hybrid triple quadrupole linear ion trap mass spectrometer. These populations are attributed to bare protonated Rivaroxaban and to a proton-bound Rivaroxaban-ammonia complex, which dissociates prior to mass-selecting the parent ion. Ultraviolet photodissociation (UVPD) and collision-induced dissociation (CID) studies indicate that both protonated Rivaroxaban ion populations are comprised of the computed global minimum prototropic isomer. Two ion populations are also observed when the collision environment is modified with 1.5% (v/v) acetonitrile. In this case, the protonated Rivaroxaban ion populations are produced by the dissociation of the ammonium complex and by the dissociation of a proton-bound Rivaroxaban-acetonitrile complex prior to mass selection. Again, both populations exhibit a similar CID behavior; however, UVPD spectra indicate that the two ion populations are associated with different prototropic isomers. The experimentally acquired spectra are compared with computed spectra and are assigned to two prototropic isomers that exhibit proton sharing between distal oxygen centers.


Assuntos
Prótons , Rivaroxabana/química , Raios Ultravioleta , Teoria da Densidade Funcional , Isomerismo , Espectrometria de Massas , Estrutura Molecular
10.
Anal Chem ; 92(16): 11053-11061, 2020 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-32698568

RESUMO

Cyclosporins are an invaluable class of drug used to prevent the rejection of transplanted tissue. While the most popular drug in this group is cyclosporin A, several other analogues are available, including some enantiomeric and structurally isomeric forms. Unfortunately, the presence of such isomers can make the detection and identification of these drugs by mass spectrometry (MS) alone quite challenging. Here, we demonstrate the separation and analysis of six cyclosporin analogues using liquid chromatography (LC) and differential mobility spectroscopy (DMS) coupled to MS. Using DMS, we demonstrate the separation of three isomers: CycA and CycH (cyclosporin H), which are enantiomers, and isocyclosporin A (a structural isomer of CycA and CycH). For several of the cyclosporins, we can separate different conformers for each isomeric form. After DMS separation, tandem mass spectrometry (MS/MS) analyses of the separated isomers also distinguish these isomeric forms of cyclosporin. In addition, we have probed differences between each isomer by using gas-phase hydrogen-deuterium exchange (HDX) immediately after DMS separation, which reveals differences in the levels of intramolecular hydrogen bonding between each of the cyclosporins.

11.
Anal Chem ; 92(17): 11973-11980, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32786479

RESUMO

Analytical methods may not have reference standards required for testing their accuracy. We postulate that the accuracy of an analytical method can be assessed in the absence of reference standards in silico if the method is built upon deterministic processes. A deterministic process can be precisely computer-simulated, thus allowing virtual experiments with virtual reference standards. Here, we apply this in silico approach to study "Accurate Constant via Transient Incomplete Separation" (ACTIS), a method for finding the equilibrium dissociation constant (Kd) of protein-small-molecule complexes. ACTIS is based on a deterministic process: molecular diffusion of the interacting protein-small-molecule pair in a laminar pipe flow. We used COMSOL software to construct a virtual ACTIS setup with a fluidic system mimicking that of a physical ACTIS instrument. Virtual ACTIS experiments performed with virtual samples-mixtures of a protein and a small molecule with defined rate constants and, thus, Kd of their interaction-allowed us to assess ACTIS accuracy by comparing the determined Kd value to the input Kd value. Further, the influence of multiple system parameters on ACTIS accuracy was investigated. Within multifold ranges of parameter values, the values of Kd did not deviate from the input Kd values by more than a factor of 1.25, strongly suggesting that ACTIS is intrinsically accurate and that its accuracy is robust. Accordingly, further development of ACTIS can focus on achieving high reproducibility and precision. We foresee that in silico accuracy assessment, demonstrated here with ACTIS, will be applicable to other analytical methods built upon deterministic processes.

12.
Anal Chem ; 92(15): 10768-10776, 2020 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-32628467

RESUMO

We present herein rPTMDetermine, an adaptive and fully automated methodology for validation of the identification of rarely occurring post-translational modifications (PTMs), using a semisupervised approach with a linear discriminant analysis (LDA) algorithm. With this strategy, verification is enhanced through similarity scoring of tandem mass spectrometry (MS/MS) comparisons between modified peptides and their unmodified analogues. We applied rPTMDetermine to (1) perform fully automated validation steps for modified peptides identified from an in silico database and (2) retrieve potential yet-to-be-identified modified peptides from raw data (that had been missed through conventional database searches). In part (1), 99 of 125 3-nitrotyrosyl-containing (nitrated) peptides obtained from a ProteinPilot search were validated and localized. Twenty nitrated peptides were falsely assigned because of incorrect monoisotopic peak assignments, leading to erroneous identification of deamidation and nitration. Five additional nitrated peptides were, however, validated after performing nonmonoisotopic peak correction. In part (2), an additional 236 unique nitrated peptides were retrieved and localized, containing 113 previously unreported nitration sites; 25 endogenous nitrated peptides with novel sites were selected and verified by comparison with synthetic analogues. In summary, we identified and confidently validated 296 unique nitrated peptides-collectively representing the largest number of endogenously identified 3-nitrotyrosyl-containing peptides from the cerebral cortex proteome of a Macaca fascicularis model of stroke. Furthermore, we harnessed the rPTMDetermine strategy to complement conventional database searching and enhance the confidence of assigning rarely occurring PTMs, while recovering many missed peptides. In a final demonstration, we successfully extended the application of rPTMDetermine to peptides featuring tryptophan oxidation.


Assuntos
Nitratos/metabolismo , Processamento de Proteína Pós-Traducional , Aprendizado de Máquina Supervisionado , Tirosina/metabolismo , Sequência de Aminoácidos , Automação , Análise Discriminante , Peptídeos/química , Peptídeos/metabolismo
13.
Anal Bioanal Chem ; 411(24): 6365-6376, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31422431

RESUMO

Up-front CID fragmentation is a phenomenon where molecular ions are activated and fragment as they enter the atmosphere-to-vacuum region of the mass spectrometer, and consequently can complicate the mass spectra and their analysis. This phenomenon can be minimized by controlling the voltages on lens/optic elements where ions are sampled from the atmospheric region, but this approach can also have a negative effect on overall ion sensitivity. In this study, we introduce gas-phase modifiers (acetonitrile, acetone, cyclohexane, water, and methanol) to the curtain gas to mitigate up-front CID fragmentation. These modifiers cluster with incoming ions, increasing the energy barrier to fragmentation and consequently reducing the complexity of mass spectra. The clustering is monitored by differential mobility spectrometry-mass spectrometry (DMS-MS) and precursor mass spectrum-scanning. Unlike typical singly charged species, peptide ion-modifier clusters were found to survive through the atmosphere-to-vacuum interface of the mass spectrometer, showing that highly charged peptides cluster most strongly with acetonitrile and acetone. In addition, when peptides cluster with acetonitrile, they produce a large increase in signal intensity for the most highly charged and fragile ions. This results in a significant reduction, up to 90% with some modifiers, in up-front CID fragmentation for these fragile highly charged peptides, increasing the overall analytical sensitivity and decreasing the limits of detection by up to 82% depending on the analyte. The proposed technique has no significant detrimental effect on the peptide mass fingerprinting of a BSA or mAb protein digest, but it does reduce the amount of redundant and data-deficient spectra needed to produce adequate sequence coverage using information-dependent acquisition methods by ~ 40%. We propose that this technique could have a benefit in the fields of proteomics and peptidomics where up-front CID fragmentation and chemical noise routinely mask targets of biological importance. Graphical abstract.


Assuntos
Espectrometria de Mobilidade Iônica/métodos , Fragmentos de Peptídeos/química , Sequência de Aminoácidos , Gases , Limite de Detecção , Fragmentos de Peptídeos/análise , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
14.
Angew Chem Int Ed Engl ; 58(20): 6635-6639, 2019 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-30901510

RESUMO

Current practical methods for finding the equilibrium dissociation constant, Kd , of protein-small molecule complexes have inherent sources of inaccuracy. Introduced here is "accurate constant via transient incomplete separation" (ACTIS), which appears to be free of inherent sources of inaccuracy. Conceptually, a short plug of the pre-equilibrated protein-small molecule mixture is pressure-propagated in a capillary, causing fast transient incomplete separation of the complex from the unbound small molecule. A superposition of signals from these two components is measured near the capillary exit and used to calculate a fraction of unbound small molecule, which, in turn, is used to calculate Kd . Herein the validity of ACTIS is proven theoretically, its accuracy is verified by computer simulation, and its practical use is demonstrated. ACTIS has the potential to become a reference-standard method for determining Kd  values of protein-small molecule complexes.


Assuntos
Eletroforese Capilar/métodos , Proteínas/química
15.
J Lipid Res ; 59(5): 910-919, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29540574

RESUMO

We report a method for comprehensive structural characterization of lipids in animal tissues using a combination of differential ion mobility spectrometry (DMS) with electron-impact excitation of ions from organics (EIEIO) mass spectrometry. Singly charged lipid ions in protonated or sodiated forms were dissociated by an electron beam having a kinetic energy of 10 eV in a branched radio-frequency ion trap. We established a comprehensive set of diagnostics to characterize the structures of glycerophospholipids, sphingolipids, and acylglycerols, including glycosylated, plasmalogen, and ester forms. This EIEIO mass spectrometer was combined with DMS as a separation tool to analyze complex lipid extracts. Deuterated quantitative standards, which were added during extraction, allowed for the quantitative analysis of the lipid molecular species in various lipid classes. We applied this technique to the total lipids extracted from porcine brain, and we structurally characterized over 300 lipids (with the exception of cis/trans double-bond isomerism in the acyl chains). The structural dataset of the lipidomes, whose regioisomers were distinguished, exhibit a uniquely defined distribution of acyl chains within each lipid class; that is, sn-1 and sn-2 in the cases of glycerophospholipids or sn-2 and (sn-1, sn-3) in the cases of triacylglycerols.


Assuntos
Elétrons , Lipídeos/análise , Espectrometria de Massas/métodos , Íons/química , Estrutura Molecular
16.
Anal Chem ; 89(14): 7307-7315, 2017 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-28613874

RESUMO

We present a mass spectrometry-based method for the identification of cis and trans double-bond isomers within intact complex lipid mixtures using electron impact excitation of ions from organics (EIEIO) mass spectrometry. EIEIO involves irradiating singly charged lipid ions with electrons having kinetic energies of 5-16 eV. The resulting EIEIO spectra can be used to discern cis and trans double-bond isomers by virtue of the differences in the fragmentation patterns at the carbon-carbon single bonds neighboring the double bonds. For trans double bonds, these characteristic fragments include unique closed-shell and open-shell (radical) products. To explain this fragmentation pattern in trans double bonds, we have proposed a reaction mechanism involving excitation of the double bond's π electrons followed by hydrogen atom rearrangement. Several lipid standards were analyzed using the EIEIO method, including mixtures of these standards. Prior to EIEIO, some of the lipid species in these mixtures were separated from their isomeric forms by using differential mobility spectrometry (DMS). For example, mixed cis and trans forms of triacylglycerols and phosphatidylcholines were identified by this DMS-EIEIO workflow. With this combined gas-phase separation and subsequent fragmentation, we could eliminate the need for authentic standards for identification. When DMS could not separate cis and trans isomers completely, as was the case with sphingomyelins, we relied upon the aforementioned diagnostic EIEIO fragment peaks to determine the relative contribution of the trans double-bond isomer in the mixed samples. We also applied the DMS-EIEIO methodology to natural samples extracted from a ruminant (bovine), which serve as common origins of trans fatty acids in a typical Western diet that includes dairy products.

17.
Anal Chem ; 89(3): 1421-1426, 2017 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-28029036

RESUMO

Targeted mass spectrometry of a surrogate peptide panel is a powerful method to study the dynamics of protein networks, but chromatographic time scheduling remains a major limitation for dissemination and implementation of robust and large multiplexed assays. We unveil a Multiple Reaction Monitoring method (Scout-MRM) where the use of spiked scout peptides triggers complex transition lists, regardless of the retention time of targeted surrogate peptides. The interest of Scout-MRM method regarding the retention time independency, multiplexing capability, reproducibility, and putative interest in facilitating method transfer was illustrated by a 782-peptide-plex relative assay targeting 445 proteins of the phytopathogen Dickeya dadantii during plant infection.


Assuntos
Cichorium intybus/metabolismo , Enterobacteriaceae/patogenicidade , Espectrometria de Massas , Peptídeos/análise , Proteômica/métodos , Cichorium intybus/microbiologia , Cromatografia Líquida de Alta Pressão , Folhas de Planta/metabolismo , Folhas de Planta/microbiologia
18.
J Lipid Res ; 57(11): 2015-2027, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27457033

RESUMO

Electron-induced dissociation or electron impact excitation of ions from organics (EIEIO) was applied to triacylglycerols (TAGs) for in-depth molecular structure analysis using MS. In EIEIO, energetic electrons (∼10 eV) fragmented TAG ions to allow for regioisomeric assignment of identified acyl groups at the sn-2 or sn-1/3 positions of the glycerol backbone. In addition, carbon-carbon double bond locations within the acyl chains could also be assigned by EIEIO. Beyond the analysis of lipid standards, this technique was applied to edible oils and natural lipid extracts to demonstrate the power of this method to provide in-depth structural elucidation of TAG molecular species.


Assuntos
Glicerol/química , Íons/química , Lipídeos/química , Triglicerídeos/química , Elétrons , Isomerismo , Espectrometria de Massas , Óleos de Plantas/química
19.
J Lipid Res ; 57(5): 858-67, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27005317

RESUMO

Electron impact excitation of ions from organics (EIEIO), also referred to as electron-induced dissociation, was applied to singly charged SM molecular species in the gas phase. Using ESI and a quadrupole TOF mass spectrometer equipped with an electron-ion reaction device, we found that SMs fragmented sufficiently to identify their lipid class, acyl group structure, and the location of double bond(s). Using this technique, nearly 200 SM molecular species were found in four natural lipid extracts: bovine milk, porcine brain, chicken egg yolk, and bovine heart. In addition to the most common backbone, d18:1, sphingosines with a range of carbon chain lengths, sphingadienes, and some sphinganine backbones were also detected. Modifications in natural SMs were also identified, including addition of iodine/methanol across a carbon-carbon double bond. This unparalleled new approach to SM analysis using EIEIO-MS shows promise as a unique and powerful tool for structural characterization.


Assuntos
Esfingomielinas/química , Animais , Química Encefálica , Bovinos , Galinhas , Gema de Ovo/química , Íons , Leite , Miocárdio/química , Oxirredução , Espectrometria de Massas por Ionização por Electrospray , Sus scrofa
20.
Anal Chem ; 87(1): 785-92, 2015 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-25423608

RESUMO

We have developed a high-throughput electron capture dissociation (ECD) device coupled to a quadrupole time-of-flight mass spectrometer using novel branched radio frequency ion trap architecture. With this device, a low-energy electron beam can be injected orthogonally into the analytical ion beam with independent control of both the ion and electron beams. While ions and electrons can interact in a "flow-through" mode, we observed a large enhancement in ECD efficiency by introducing a short ion trapping period at the region of ion and electron beam intersection. This simultaneous trapping mode still provides up to five ECD spectra per second while operating in an information-dependent acquisition workflow. Coupled to liquid chromatography (LC), this LC-ECD workflow provides good sequence coverage for both trypsin and Lys C digests of bovine serum albumin, providing ECD spectra for doubly charged precursor ions with very good efficiency.


Assuntos
Cromatografia Líquida/métodos , Elétrons , Soroalbumina Bovina/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Animais , Bovinos , Íons , Lisina/química , Ondas de Rádio , Espectroscopia de Infravermelho com Transformada de Fourier , Tripsina/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA