Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 300
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Lupus ; 23(12): 1324-6, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25228739

RESUMO

Activation of the complement cascade is an important mechanism for antiphospholipid antibody-mediated thrombosis. We examined the effects of rEV576 (coversin), a recombinant protein inhibitor of complement factor 5 activation, on antiphospholipid antibody-mediated tissue factor up-regulation and thrombosis. Groups of C57BL/6J mice (n=5) received either IgG from a patient with antiphospholipid syndrome (APS) or control IgG from normal human serum (NHS). Each of these groups of mice had IgG administration preceded by either rEV576, or phosphate buffer control. For each of the four treatment groups, the size of induced thrombus, tissue factor activity in carotid homogenates, anticardiolipin and anti-ß2glycoprotein I (anti-ß2GPI) levels were measured 72 h after the first injection. Mice treated with IgG-APS had significantly higher titers of anticardiolipin antibodies and anti-ß2GPI at thrombus induction compared with those treated with IgG-NHS. The IgG-APS/phosphate buffer treatment induced significantly larger thrombi and tissue factor activity compared with other groups. Mice treated with IgG-APS/rEV576 had significantly smaller thrombi and reduced tissue factor activity than those treated with IgG-APS/phosphate buffer. The data confirm involvement of complement activation in antiphospholipid antibody-mediated thrombogenesis and suggest that complement inhibition might ameliorate this effect.


Assuntos
Anticorpos Antifosfolipídeos/imunologia , Complemento C5/antagonistas & inibidores , Trombose/prevenção & controle , Animais , Camundongos , Camundongos Endogâmicos C57BL , Proteínas Recombinantes/farmacologia , Tromboplastina/análise , Trombose/etiologia , beta 2-Glicoproteína I/imunologia
2.
Haemophilia ; 19(2): 338-42, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23205618

RESUMO

The ristocetin cofactor assay (VWF:RCo) is the reference method for assessing von Willebrand factor (VWF) activity in the diagnosis of von Willebrand's Disease (VWD). However, the assay suffers from poor reproducibility and sensitivity at low levels of VWF and is labour intensive. We have undertaken an evaluation of a new immunoturbidimetric VWF activity (VWF:Ac) assay (INNOVANCE(®) VWF Ac. Siemens Healthcare Diagnostics, Marburg, Germany) relative to an established platelet-based VWF:RCo method. Samples from 50 healthy normal subjects, 80 patients with VWD and 50 samples that exhibited 'HIL' (i.e. Haemolysis, Icterus or Lipaemia) were studied. VWF:Ac, VWF:RCo and VWF:Ag were performed on a CS-analyser (Sysmex UK Ltd, Milton Keynes, UK), all reagents were from Siemens Healthcare Diagnostics. The VWF:Ac assay, gave low intra- and inter-assay imprecision (over a 31-day period, n = 200 replicate readings) using commercial normal (Mean 96.2 IU dL(-1), CV < 3.0%) and pathological (Mean 36.1 IU dL(-1), CV < 3.5%) control plasmas. The normal and clinical samples exhibited good correlation between VWF:RCo (range 3-753 IU dL(-1)) and VWF:Ac (rs = 0.97, P < 0.0001), with a mean bias of 5.6 IU dL(-1). Ratios of VWF:Ac and VWF:RCo to VWF:Ag in the VWD samples were comparable, although VWF:Ac had a superior lower level of detection to that of VWF:RCo (3% and 5% respectively). A subset (n = 97) of VWD and HIL samples were analysed for VWF:Ac at two different dilutions to assess the effect on relative potency, no significant difference was observed (P = 0.111). The INNOVANCE(®) VWF Ac assay was shown to be reliable and precise.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Doenças de von Willebrand/diagnóstico , Fator de von Willebrand/análise , Anticorpos Monoclonais , Humanos , Receptores de GABA-B/metabolismo , Reprodutibilidade dos Testes
3.
Lupus ; 22(1): 18-25, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22988029

RESUMO

The updated international consensus criteria for definite antiphospholipid syndrome (APS) are useful for scientific clinical studies. However, there remains a need for diagnostic criteria for routine clinical use. We audited the results of routine antiphospholipid antibodies (aPLs) in a cohort of 193 consecutive patients with aPL positivity-based testing for lupus anticoagulant (LA), IgG and IgM anticardiolipin (aCL) and anti-ß(2)glycoprotein-1 antibodies (aß(2)GPI). Medium/high-titre aCL/aß(2)GPI was defined as >99th percentile. Low-titre aCL/aß(2)GPI positivity (>95(th )< 99(th) percentile) was considered positive for obstetric but not for thrombotic APS. One hundred of the 145 patients fulfilled both clinical and laboratory criteria for definite APS. Twenty-six women with purely obstetric APS had persistent low-titre aCL and/or aß(2)GPI. With the inclusion of these patients, 126 of the 145 patients were considered to have APS. Sixty-seven out of 126 patients were LA-negative, of whom 12 had aCL only, 37 had aß(2)GPI only and 18 positive were for both. The omission of aCL or aß(2)GPI testing from investigation of APS would have led to a failure to diagnose APS in 9.5% and 29.4% of patients, respectively. Our data suggest that LA, aCL and aß(2)GPI testing are all required for the accurate diagnosis of APS and that low-titre antibodies should be included in the diagnosis of obstetric APS.


Assuntos
Anticorpos Anticardiolipina/sangue , Síndrome Antifosfolipídica/diagnóstico , Inibidor de Coagulação do Lúpus/sangue , Complicações na Gravidez/diagnóstico , Trombose/diagnóstico , beta 2-Glicoproteína I/imunologia , Síndrome Antifosfolipídica/sangue , Síndrome Antifosfolipídica/imunologia , Biomarcadores/sangue , Feminino , Humanos , Modelos Lineares , Masculino , Valor Preditivo dos Testes , Gravidez , Complicações na Gravidez/sangue , Complicações na Gravidez/imunologia , Estudos Retrospectivos , Trombose/sangue , Trombose/imunologia
4.
Haemophilia ; 17(2): 252-6, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21070498

RESUMO

von Willebrand's disease (VWD) is regarded as the most common congenital bleeding disorder, and although not available in all laboratories von Willebrand factor (VWF) activity is most frequently assessed as ristocetin cofactor (VWF:RCo). This test can be technically challenging, is subject to poor sensitivity (∼20 IU dL(-1) VWF:RCo) and has a high degree of inter- and intra-assay imprecision [coefficient of variation (cv) > 25%]. We studied an automated assay using a combined fixed platelet/ristocetin reagent (BC von Willebrand reagent, Siemens Healthcare Diagnostics) on the CS-2000i analyser (Sysmex UK Ltd). Initially inter- and intra-assay imprecision was assessed. The automated method showed good day-to-day reproducibility and linearity of standard curves. This technique, also gave low intra- and inter-assay imprecision using commercial normal (cv < 4.5%) and pathological (cv < 8.1%) control plasmas. We then compared automated technique results from 30 healthy normal subjects and 39 VWD patients to those obtained using standard aggregometry (Bio/Data, PAP4) with lyophilised fixed platelets (Helena BioSciences) and ristocetin (American Biochemical and Pharmaceutical Ltd). The automated method had a sensitivity limit of approximately 10 IU dL(-1) vs. 20 IU dL(-1) for aggregometry. Samples giving results within the aggregometry measurable range (n = 50) exhibited good correlation with the automated technique (median 70 IU dL(-1), range 7-184 IU dL(-1); and 64 IU dL(-1), 6-138 IU dL(-1) respectively; R(2) = 0.85). We subsequently compared 3 different batches of BC von Willebrand reagent, using a second group of normal subjects and VWD patients (n = 35, 55-139 IU dL(-1) and n = 30, <10-50 IU dL(-1)). The CS-2000i results exhibited no clinically significant variation between batches (mean cv = 7%). The automated VWF:RCo assay offers a more sensitive, reproducible, robust and less laborious alternative to standard aggregometry.


Assuntos
Testes de Coagulação Sanguínea/métodos , Doenças de von Willebrand/diagnóstico , Fator de von Willebrand/análise , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Doenças de von Willebrand/sangue
5.
Lupus ; 20(2): 219-24, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21303838

RESUMO

The Antiphospholipid Syndrome (APS) Clinical Research Task Force (CRTF) was one of six Task Forces developed by the 13(th) International Congress on Antiphospholipid Antibodies (aPL) organization committee with the purpose of: a) evaluating the limitations of APS clinical research and developing guidelines for researchers to help improve the quality of APS research; and b) prioritizing the ideas for a well-designed multicenter clinical trial and discussing the pragmatics of getting such a trial done. Following a systematic working algorithm, the Task Force identified five major issues that impede APS clinical research and the ability to develop evidence-based recommendations for the management of aPL-positive patients: (1) aPL detection has been based on partially or non-standardized tests, and clinical (and basic) APS research studies have included patients with heterogeneous aPL profiles with different clinical event risks; (2) clinical (and basic) APS research studies have included a heterogeneous group of patients with different aPL-related manifestations (some controversial); (3) thrombosis and/or pregnancy risk stratification and quantification are rarely incorporated in APS clinical research; (4) most APS clinical studies include patients with single positive aPL results and/or low-titer aPL ELISA results; furthermore, study designs are mostly retrospective and not population based, with limited number of prospective and/or controlled population studies; and (5) lack of the understanding the particular mechanisms of aPL-mediated clinical events limits the optimal clinical study design. The Task Force recommended that there is an urgent need for a truly international collaborative approach to design and conduct well-designed prospective large-scale multi-center clinical trials of patients with persistent and clinically significant aPL profiles. An international collaborative meeting to formulate a good research question using 'FINER' (Feasible; Interesting; Novel; Ethical; and Relevant) criteria took place in November 2010.


Assuntos
Comitês Consultivos , Síndrome Antifosfolipídica , Pesquisa Biomédica , Anticorpos Antifosfolipídeos , Ensaios Clínicos como Assunto , Congressos como Assunto , Feminino , Humanos , Gravidez
6.
Lupus ; 20(2): 206-18, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21303837

RESUMO

The antiphospholipid syndrome (APS) is defined by the presence of thrombosis and/or pregnancy morbidity in combination with the persistent presence of circulating antiphospholipid antibodies: lupus anticoagulant, anticardiolipin antibodies and/or anti-ß2-glycoprotein I antibodies in medium to high titers. The management of thrombosis in patients with APS is a subject of controversy. This set of recommendations is the result of an effort to produce guidelines for therapy within a group of specialist physicians in Cardiology, Neurology, Hematology, Rheumatology and Internal Medicine, with a clinical and research focus on APS.


Assuntos
Anticorpos Antifosfolipídeos/sangue , Síndrome Antifosfolipídica/sangue , Síndrome Antifosfolipídica/imunologia , Trombose/prevenção & controle , Trombose/terapia , Comitês Consultivos , Anticorpos Antifosfolipídeos/efeitos adversos , Síndrome Antifosfolipídica/complicações , Ensaios Clínicos como Assunto , Congressos como Assunto , Feminino , Humanos , Gravidez , Texas , Trombose/sangue , Trombose/etiologia
7.
Lupus ; 19(4): 486-91, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20353992

RESUMO

Anticoagulation with oral vitamin K antagonists (VKA) is the mainstay of the treatment of venous and/or arterial thromboembolism in patients with antiphospholipid syndrome (APS), although the optimal intensity of anticoagulation remains controversial. The limitations of existing anticoagulants have driven a search for novel agents. Dabigatran etexilate (Pradaxa), a direct thrombin inhibitor (DTI), and rivaroxaban (Xarelto), the first in a new class of drugs, the oral direct factor Xa (FXa) inhibitors, are both fixed-dose orally administered agents. They are now licensed in the UK and Europe for the prevention of venous thromboembolism (VTE) in adult patients undergoing elective total hip replacement (THR) or total knee replacement (TKR). Prospective randomized clinical trials suggest that these agents, and also apixaban, a further oral direct anti-Xa inhibitor, may have potential in other areas including the treatment of acute VTE, prevention of stroke or systemic embolism in patients with atrial fibrillation (AF) and acute coronary syndromes. Here, we summarize current indications for these agents and address the potential for their use in patients with thrombotic APS.


Assuntos
Anticoagulantes/uso terapêutico , Síndrome Antifosfolipídica/tratamento farmacológico , Fibrinolíticos/uso terapêutico , Adulto , Animais , Anticoagulantes/farmacologia , Síndrome Antifosfolipídica/complicações , Desenho de Fármacos , Fibrinolíticos/farmacologia , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Tromboembolia/tratamento farmacológico , Tromboembolia/etiologia , Resultado do Tratamento , Vitamina K/antagonistas & inibidores
8.
Vox Sang ; 99(3): 232-8, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20840338

RESUMO

BACKGROUND: Octapharma PPGmbH has recently modified its manufacturing process for solvent/detergent-treated plasma to incorporate a prion reduction step, in which a 3 log reduction has been demonstrated. The current study was undertaken to assess the impact of this procedure on haemostatic variables in the new product OctaplasLG in comparison with standard Octaplas. METHODS: Production batches of standard Octaplas (n=4) and OctaplasLG (n=16) were assessed for levels of coagulation factors, physiological protease inhibitors, markers of activation and procoagulant microparticles. Global haemostasis was assessed by a thrombin generation test (TGT) and rotational thromboelastometry (ROTEM). RESULTS: Mean levels of factors: II, V, VII, IX, X, XI, XII and XIII, VWF:Ag, antithrombin, protein C and free protein S were all >75 u/dl. ADAMTS-13 activity levels were normal. Factor VIII and VWF:RCo were >55 u/dl. TGT and ROTEM were similar in both preparations, and microparticles were present at negligible levels. Two units of OctaplasLG had slightly elevated levels of Prothrombin Fragments 1+2, but D-Dimer and thrombin-antithrombin complexes were normal in all batches. CONCLUSION: These studies indicate that the affinity chromatography procedure used in OctaplasLG does not appear to adversely affect the proven haemostatic quality of Octaplas, while offering a selective reduction in the concentration of pathological prion proteins.


Assuntos
Proteínas Sanguíneas/análise , Hemostáticos/análise , Plasma/química , Príons , Cromatografia de Afinidade/métodos , Humanos
9.
Br J Haematol ; 144(3): 430-3, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19036107

RESUMO

Thrombotic thrombocytopenic purpura (TTP) may be idiopathic or secondary. We report seven TTP cases precipitated by pancreatitis. The patients were admitted with acute pancreatitis and at that time had no clinical or laboratory features of TTP. The median time to develop TTP after pancreatitis was 3 d. The patients had moderately reduced ADAMTS13 activity (mean activity 49%; normal range 66-126%) with no evidence of anti-ADAMTS13 inhibitory autoantibodies. The median number of plasma exchanges to remission was 10 (range 7-14) and no additional treatment with immunosuppression was required to maintain remission. There have been no relapses to date.


Assuntos
Pancreatite/complicações , Púrpura Trombocitopênica Trombótica/etiologia , Proteínas ADAM/análise , Proteína ADAMTS13 , Doença Aguda , Adulto , Idoso , Autoanticorpos/análise , Feminino , Seguimentos , Humanos , Imunoglobulina G/análise , Masculino , Pancreatite/imunologia , Pancreatite/terapia , Troca Plasmática , Púrpura Trombocitopênica Trombótica/imunologia , Púrpura Trombocitopênica Trombótica/terapia , Resultado do Tratamento , Adulto Jovem
10.
Br J Haematol ; 141(4): 536-44, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18341632

RESUMO

Autoantibodies to ADAMTS13 (a disintegrin-like and metalloprotease with thrombospondin type I motif, member 13) play an important role in the development of microthrombosis in thrombotic thrombocytopenic purpura (TTP). In severe cases of antiphospholipid syndrome (APS), microthrombosis can occur similar to that seen in TTP, suggesting possible mutual pathogenic factors. However, the role of ADAMTS13 in APS is unknown. We hypothesised that aberrations in ADAMTS13 may occur in APS and evaluated ADAMTS13 and von Willebrand factor (VWF) in 68 patients with antiphospholipid antibodies (aPA) including 52 with APS. Thirty-three (49%) had IgG anti-ADAMTS13 with 12 of these patients having reduced ADAMTS13 activity, suggesting neutralising antibodies. Low ADAMTS13 activity (median 34%) was demonstrated in 22/68 (33%), all with normal ADAMTS13 antigen levels consistent with dysfunctional ADAMTS13. Reduced ADAMTS13 activity was not secondary to elevated von Willebrand factor (VWF), or increased VWF secretion (normal VWF propeptide), although a reduced VWF clearance was noted in APS. Analysis found no associations between the ADAMTS13 abnormalities and any aPA profile or thrombotic/obstetric complications, although this study was not adequately powered to address clinical associations. Nevertheless, these findings highlight that ADAMTS13 autoantibodies and ADAMTS13 dysfunction can occur in APS, and although the clinical significance remains undetermined, ADAMTS13 dysfunction may be contributory to thrombogenesis in autoimmune conditions other than TTP.


Assuntos
Proteínas ADAM/imunologia , Síndrome Antifosfolipídica/imunologia , Autoanticorpos/sangue , Fator de von Willebrand/metabolismo , Proteínas ADAM/sangue , Proteínas ADAM/fisiologia , Proteína ADAMTS13 , Adulto , Idoso , Feminino , Meia-Vida , Humanos , Imunoglobulina G/sangue , Masculino , Pessoa de Meia-Idade
11.
Vox Sang ; 94(4): 306-14, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18266780

RESUMO

BACKGROUND: Factor VIII (FVIII) levels are used as a quality marker of fresh-frozen plasma (FFP); however, other clotting factors are not routinely measured. METHODS: We assessed additional haemostatic parameters and the dynamics of coagulation using Thrombelastography (TEG) and a thrombin generation test (TGT). FFP was prepared on the day of donation (Day 0) or after overnight hold at 4 degrees C (Day 1). RESULTS: Factor VIII in Day 1 FFP was 18% lower than in Day 0. TEG parameters in Day 1 FFP were consistent with increased coagulability and did not correlate with altered levels of clotting factors, but were consistent with the increased levels of microparticles seen in the Day 1 samples. TGT studies exhibited increased lag time, time to peak and reduced peak thrombin generation, but no change in endogenous thrombin potential (ETP) on Day 1. There was a weak association between FVIII level and both ETP and peak thrombin (ETP r(s)> or = 0.22, P< or = 0.003; peak thrombin r(s)> or = 0.48, P< or = 0.0001), which was influenced by ABO group, with the lowest levels in group O. CONCLUSION: We conclude that levels of FVIII do not predict the haemostatic potential of FFP and that there may be a role for alternative technologies in monitoring the quality of FFP.


Assuntos
Coagulação Sanguínea/fisiologia , Fator VIII/análise , Plasma/fisiologia , Humanos , Plasma/química , Controle de Qualidade , Tromboelastografia
12.
Int J Lab Hematol ; 39(6): 585-589, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28649771

RESUMO

INTRODUCTION: The XN-550 is a new, automated, compact, haematology analyser designed to generate a full blood count with a standard five-part white blood cell differential and an immature granulocyte count, as well as an optional reticulocyte and optical platelet (PLT) counts. The aim of the study was to evaluate the performance of the XN-550 and compare it to the established XN-20 system. METHODS: We evaluated the basic parameter and special measurement channels of the XN-550, using the XN-20 (which has a similar operating system), as a reference analyser. Precision, carry-over and throughput evaluations were performed. In addition, a total of 202 samples including normal controls and various pathological samples were studied for comparability. RESULTS: Good correlations with the reference analyser were obtained for all parameters except basophils. The XN-550 offers impedance and optical PLT counts and the latter showed a better correlation and less scatter than the impedance count and was comparable to the XN-20 fluorescent count at PLT counts ≤40×109 /L. Precision was good, and no significant carry-over was detected. CONCLUSIONS: The XN-550 was simple and easy to use, while maintaining the good diagnostic sensitivity seen with high-range systems such as the XN-20, making this compact device suitable for near-patient services and smaller satellite laboratories.


Assuntos
Testes Hematológicos/instrumentação , Testes Hematológicos/métodos , Feminino , Humanos , Masculino
13.
Int J Lab Hematol ; 39(5): 448-457, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28497537

RESUMO

INTRODUCTION: The gold standard for the determination of the erythrocyte sedimentation rate (ESR) is the Westergren method. Other methods to measure the ESR have become available. They range from modest modifications of the Westergren method to very different methodologies. The ICSH therefore established a Working Group to investigate these new approaches and compile recommendations for their validation and verification. METHODS: A panel of six experts in laboratory hematology examined the peer-reviewed literature and EQA surveys from over 6000 laboratories on four continents performing ESR testing. This information was used to create lists of ESR instrument manufacturers and their methods. RESULTS: Only 28% of laboratories surveyed used the unmodified Westergren method, while 72% of sites used modified or alternate methods. Results obtained with the new instruments could differ from results obtained with the Westergren method by up to 142%. Different non-Westergren methods showed differences from each other of up to 42%. The new methods were often significantly faster, safer, and less labor-intensive. They reduced costs and often used standard EDTA tubes, eliminating the need for a dedicated ESR tube. CONCLUSION: Based on the consensus of the Working Group, recommendations for manufacturers for the validation of new ESR methods were developed. In addition, a list of recommendations for laboratories that are moving to modified or alternate methods was compiled, addressing instrument performance verification and communications of results to clinical users.


Assuntos
Sedimentação Sanguínea , Testes Hematológicos/métodos , Testes Hematológicos/normas , Automação Laboratorial , Prova Pericial , Testes Hematológicos/instrumentação , Humanos , Guias de Prática Clínica como Assunto
14.
Int J Lab Hematol ; 39(5): 532-538, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28603894

RESUMO

INTRODUCTION: A new prothrombin time reagent (Revohem™ PT) based on recombinant human tissue factor produced by the silkworm-baculovirus expression system was tested. The aim of this study was to compare the performance of the new PT reagent with two widely used routine PT reagents. METHODS: All testing was performed on a Sysmex CS-5100 coagulometer. Revohem™ PT was tested for imprecision and stability using normal and abnormal lyophilized commercial control plasmas. Comparability was assessed with two widely used reagents: one containing recombinant human tissue factor (Reagent A) and the other a human placental thromboplastin (Reagent B) using a wide range of normal and abnormal plasmas and analyser-specific ISI values. RESULTS: Excellent between-day imprecision was obtained for Revohem™ PT (CV <1.0%) and acceptable open-vial on-board stability over 7 days. There was good agreement between methods in samples from patients with liver disease and patients receiving warfarin and no significant differences between methods with increasing INR values. Both recombinant reagents suffered less interference from lupus anticoagulant than the placental thromboplastin. Revohem™ PT had similar sensitivity to reagents A and B for FII, V, VII and X deficiency and demonstrated dose responsiveness to dabigatran, apixaban and rivaroxaban with steeper response curves than the comparison reagents. CONCLUSION: Revohem™ PT showed comparable or improved performance relative to two widely used reagents and is suitable for use in warfarin control, detection of inherited factor II, V, VII and X deficiency and assessment of liver disease coagulopathy.


Assuntos
Tempo de Protrombina/métodos , Tempo de Protrombina/normas , Kit de Reagentes para Diagnóstico/normas , Humanos , Coeficiente Internacional Normatizado , Protrombina , Tempo de Protrombina/instrumentação , Proteínas Recombinantes , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
15.
J Thromb Haemost ; 14(11): 2177-2186, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27541499

RESUMO

Essentials Complement activation has a pathogenic role in thrombotic antiphospholipid syndrome (APS). Coagulation proteases such as factor Xa can activate complement proteins. Complement activation markers were elevated in anticoagulated thrombotic APS patients. Complement activation decreased in APS patients switching from warfarin to rivaroxaban. SUMMARY: Background Complement activation may play a major role in the pathogenesis of thrombotic antiphospholipid syndrome (APS). Coagulation proteases such as factor Xa can activate complement proteins. Aims To establish whether rivaroxaban, a direct factor Xa inhibitor, limits complement activation compared with warfarin in APS patients with previous venous thromboembolism (VTE). Methods A total of 111 APS patients with previous VTE, on warfarin target INR 2.5, had blood samples taken at baseline and at day 42 after randomization in the RAPS (Rivaroxaban in Antiphospholipid Syndrome) trial. Fifty-six patients remained on warfarin and 55 switched to rivaroxaban. Fifty-five normal controls (NC) were also studied. Markers of complement activation (C3a, C5a, terminal complement complex [SC5b-9] and Bb fragment) were assessed. Results APS patients had significantly higher complement activation markers compared with NC at both time-points irrespective of the anticoagulant. There were no differences between the two patient groups at baseline, or patients remaining on warfarin at day 42. In 55 patients randomized to rivaroxaban, C3a, C5a and SC5b-9 were lower at day 42 (median (ng mL-1 ) [confidence interval] 64 [29-125] vs. 83 [35-147], 9 [2-15] vs. 12 [4-18] and 171 [56-245] vs. 201 [66-350], respectively) but levels of Bb fragment were unchanged. There were no correlations between rivaroxaban levels and complement activation markers. Conclusions APS patients with previous VTE on warfarin exhibit increased complement activation, which is likely to occur via the classical pathway and is decreased by rivaroxaban administration. Rivaroxaban may therefore potentially provide an additional benefit to its anticoagulant effect in this patient group by limiting complement activation.


Assuntos
Anticoagulantes/uso terapêutico , Síndrome Antifosfolipídica/tratamento farmacológico , Coagulação Sanguínea/efeitos dos fármacos , Inibidores do Fator Xa/uso terapêutico , Rivaroxabana/uso terapêutico , Tromboembolia Venosa/tratamento farmacológico , Varfarina/uso terapêutico , Adulto , Síndrome Antifosfolipídica/sangue , Síndrome Antifosfolipídica/complicações , Ativação do Complemento , Fator Xa/química , Feminino , Humanos , Inflamação/tratamento farmacológico , Coeficiente Internacional Normatizado , Masculino , Pessoa de Meia-Idade , Trombose/sangue , Tromboembolia Venosa/sangue , Tromboembolia Venosa/complicações
16.
J Thromb Haemost ; 3(6): 1266-73, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15946217

RESUMO

BACKGROUND: Cellular prion protein (PrP(C)) is a naturally occurring protein in normal individuals which adopts an abnormal conformation, termed scrapie prion protein (PrP(Sc)) that is associated with disease. There is great concern that clinically asymptomatic variant Creutzfeldt-Jacob disease (vCJD) may transmit PrP(Sc) in blood transfusion products. PrP(C) is widely expressed and has been found in human blood. The majority of cellular borne PrP(C) is associated with platelets (84%). Although PrP(C) mRNA has been demonstrated in platelets, the quantity is unknown and may not reflect the total PrP(C) present. OBJECTIVE: To investigate the expression of PrP(C) in the megakaryocyte lineage. METHODS: The expression of PrP(C) was studied in CD34+ cells, cultured megakaryocytes and platelets using electron microscopy, flow cytometry, semi-quantitative RT-PCR and immunofluorescence confocal microscopy. RESULTS AND CONCLUSIONS: The expression of PrP(C) appeared to increase with differentiation and polyploidization in the megakaryocyte lineage. PrP(C) was located within platelet alpha-granules and its source is likely to be from megakaryocyte precursors. If PrP(Sc) has a similar distribution, these results have implications for the selection of blood donors and preparation of cell-depleted blood products.


Assuntos
Megacariócitos/química , Proteínas PrPC/análise , Antígenos CD34 , Plaquetas/química , Diferenciação Celular , Linhagem da Célula , Células Cultivadas , Grânulos Citoplasmáticos/química , Células-Tronco Hematopoéticas/química , Humanos , Megacariócitos/citologia , Proteínas PrPC/genética , RNA Mensageiro/análise
17.
Int J STD AIDS ; 16(8): 538-42, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16105187

RESUMO

Thrombotic thrombocytopaenic purpura (TTP) results from deficiency of von Willebrand factor-cleaving protease (vWF-cp) activity. Eight HIV-infected patients presented with TTP, representing 12.5% of all TTP treated at this centre. In four patients presentation with TTP revealed underlying HIV infection, the other four patients were previously known to be HIV infected, with plasma exchange and highly active antiretroviral therapy (HAART) all recovered. Normalization of vWF-cp activity was associated with recovery. Relapse occurred in two patients who discontinued HAART against medical advice, suggesting that HIV has a causal role in this condition. Given the clear benefit from HAART in addition to plasma exchange, these data suggest that all patients presenting with TTP should undergo HIV testing.


Assuntos
Infecções por HIV/complicações , Metaloendopeptidases/deficiência , Púrpura Trombocitopênica Trombótica/etiologia , Terapia Antirretroviral de Alta Atividade , HIV , Infecções por HIV/tratamento farmacológico , Humanos , Púrpura Trombocitopênica Trombótica/sangue , Recidiva , Fator de von Willebrand/metabolismo
18.
J Thromb Haemost ; 13(7): 1264-73, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25850997

RESUMO

INTRODUCTION: Rivaroxaban can affect lupus anticoagulant (LA) testing and antiphospholipid antibodies (aPL) may interfere with the anticoagulant action of rivaroxaban. AIMS: To establish the influence of rivaroxaban on LA detection and of aPL on the anticoagulant action of rivaroxaban. METHODS: Rivaroxaban and 52 IgG preparations (20 LA+ve, 12 LA-ve thrombotic antiphospholipid syndrome [APS] patients, and 20 normal controls [NC]) were spiked into pooled normal plasma (PNP) for relevant studies. LA detection was also studied in APS patients receiving rivaroxaban 20 mg once daily. RESULTS: In vitro spiking of samples with rivaroxaban showed no false positive LA with Textarin time, Taipan venom time/Ecarin clotting time (TVT/ECT), dilute prothrombin time (dPT) and in-house dilute Russell's viper venom time (DRVVT), but false positives in the majority of NC and LA negative IgG with two commercial DRVVT reagents at 250 ng/mL but not 50 ng/mL rivaroxaban. Ex vivo studies: six LA+ve patients on rivaroxaban remained LA positive with TVT/ECT and DRVVT at peak (162-278 ng/mL) and trough (30-85 ng/mL) rivaroxaban levels. Six LA-ve patients became (apparently) LA+ve with two DRVVT reagents (test/confirm ratio median [confidence interval], 1.6 [1.3-1.8], 1.6 [1.4-1.9]) but not with TVT/ECT at peak rivaroxaban levels, and remained LA-ve with both DRVVT reagents and TVT/ECT at trough levels. aPL positive IgG spiking of PNP had no effect on rivaroxaban's anticoagulant action on thrombin generation or rivaroxaban anti-Xa levels. CONCLUSIONS: The TVT/ECT ratio and Textarin time were not affected even at peak rivaroxaban levels, enabling detection of LA ex vivo. aPL had no effects on rivaroxaban's anticoagulant action in vitro.


Assuntos
Anticorpos Antifosfolipídeos/sangue , Síndrome Antifosfolipídica/tratamento farmacológico , Coagulação Sanguínea/efeitos dos fármacos , Inibidores do Fator Xa/uso terapêutico , Imunoglobulina G/sangue , Rivaroxabana/uso terapêutico , Trombose/tratamento farmacológico , Síndrome Antifosfolipídica/sangue , Síndrome Antifosfolipídica/diagnóstico , Biomarcadores/sangue , Testes de Coagulação Sanguínea , Estudos de Casos e Controles , Inibidores do Fator Xa/efeitos adversos , Reações Falso-Positivas , Humanos , Inibidor de Coagulação do Lúpus/sangue , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Rivaroxabana/efeitos adversos , Trombose/sangue , Trombose/diagnóstico , Resultado do Tratamento
19.
Thromb Res ; 135(2): 388-93, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25555316

RESUMO

INTRODUCTION: Rivaroxaban is non-inferior to warfarin for the treatment of venous thromboembolism, with regard to clinical efficacy and safety. The ex-vivo effects of warfarin versus therapeutic dose rivaroxaban on in-vivo markers of coagulation activation and thrombin generation remain undefined. The aim of this study was to compare the effects of warfarin and therapeutic dose rivaroxaban on ex-vivo thrombin generation (TG), and the in-vivo markers of coagulation activation, prothrombin fragment 1.2 (F1.2), thrombin-antithrombin complex (TAT), and D-dimer. METHODS: Eighty-five patients with venous thromboembolism were studied, 45 on warfarin, target INR 2.5 and 40 on rivaroxaban 20mg once daily. RESULTS: Anticoagulation was in therapeutic range in 71% (32/45) warfarin and 65% (26/40) rivaroxaban treated patients. 8 patients on warfarin and 9 patients on rivaroxaban had subtherapeutic INR and rivaroxaban levels respectively. Both rivaroxaban and warfarin reduced endogenous thrombin potential (ETP) and peak thrombin, and prolonged lag time and time to peak, compared to normal controls (p<0.0001). The lag time and time to peak TG were longer, and peak thrombin was lower in patients receiving rivaroxaban (p<0.0001) compared with warfarin, although warfarin-treated patients had lower ETP (p=0.0008). In-vivo coagulation activation markers were within the normal ranges in all rivaroxaban-treated patients (including those with levels considered to be subtherapeutic) and in 37/45 warfarin-treated patients who had an INR≥2.0. The warfarin-treated patients with subtherapeutic INRs exhibited slightly raised F1.2 and/or TAT. CONCLUSION: In conclusion, both rivaroxaban and warfarin provided effective anticoagulation, as assessed by inhibition of TG and makers of in-vivo coagulation activation.


Assuntos
Anticoagulantes/uso terapêutico , Inibidores do Fator Xa/uso terapêutico , Coeficiente Internacional Normatizado/métodos , Morfolinas/uso terapêutico , Tiofenos/uso terapêutico , Tromboembolia Venosa/tratamento farmacológico , Adulto , Idoso , Coagulação Sanguínea/efeitos dos fármacos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Rivaroxabana , Varfarina/uso terapêutico
20.
Int J Lab Hematol ; 37(3): 287-303, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25728865

RESUMO

These guidelines provide information on how to reliably and consistently report abnormal red blood cells, white blood cells and platelets using manual microscopy. Grading of abnormal cells, nomenclature and a brief description of the cells are provided. It is important that all countries in the world use consistent reporting of blood cells. An international group of morphology experts have decided on these guidelines using consensus opinion. For some red blood cell abnormalities, it was decided that parameters produced by the automated haematology analyser might be more accurate and less subjective than grading using microscopy or automated image analysis and laboratories might like to investigate this further. A link is provided to show examples of many of the cells discussed in this guideline.


Assuntos
Células Sanguíneas/citologia , Células Sanguíneas/patologia , Testes Hematológicos/normas , Microscopia , Humanos , Guias de Prática Clínica como Assunto , Terminologia como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA