Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
J Nanobiotechnology ; 21(1): 115, 2023 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-36978078

RESUMO

BACKGROUND: The lack of predictive models that mimic the blood-brain barrier (BBB) hinders the development of effective drugs for neurodegenerative diseases. Animal models behave differently from humans, are expensive and have ethical constraints. Organ-on-a-chip (OoC) platforms offer several advantages to resembling physiological and pathological conditions in a versatile, reproducible, and animal-free manner. In addition, OoC give us the possibility to incorporate sensors to determine cell culture features such as trans-endothelial electrical resistance (TEER). Here, we developed a BBB-on-a-chip (BBB-oC) platform with a TEER measurement system in close distance to the barrier used for the first time for the evaluation of the permeability performance of targeted gold nanorods for theranostics of Alzheimer's disease. GNR-PEG-Ang2/D1 is a therapeutic nanosystem previously developed by us consisting of gold nanorods (GNR) functionalized with polyethylene glycol (PEG), angiopep-2 peptide (Ang2) to overcome the BBB and the D1 peptide as beta amyloid fibrillation inhibitor, finally obtaining GNR-PEG-Ang2/D1 which showed to be useful for disaggregation of the amyloid in in vitro and in vivo models. In this work, we evaluated its cytotoxicity, permeability, and some indications of its impact on the brain endothelium by employing an animal-free device based on neurovascular human cells. RESULTS: In this work, we fabricated a BBB-oC with human astrocytes, pericytes and endothelial cells and a TEER measuring system (TEER-BBB-oC) integrated at a micrometric distance of the endothelial barrier. The characterization displayed a neurovascular network and the expression of tight junctions in the endothelium. We produced GNR-PEG-Ang2/D1 and determined its non-cytotoxic range (0.05-0.4 nM) for plated cells included in the BBB-oC and confirmed its harmless effect at the highest concentration (0.4 nM) in the microfluidic device. The permeability assays revealed that GNR-PEG-Ang2/D1 cross the BBB and this entry is facilitated by Ang2 peptide. Parallel to the permeability analysis of GNR-PEG-Ang2/D1, an interesting behavior of the TJs expression was observed after its administration probably related to the ligands on the nanoparticle surface. CONCLUSIONS: BBB-oC with a novel TEER integrated setup which allow a correct read-out and cell imaging monitoring was proven as a functional and throughput platform to evaluate the brain permeability performance of nanotherapeutics in a physiological environment with human cells, putting forward a viable alternative to animal experimentation.


Assuntos
Doença de Alzheimer , Barreira Hematoencefálica , Humanos , Barreira Hematoencefálica/metabolismo , Células Endoteliais/metabolismo , Doença de Alzheimer/tratamento farmacológico , Doença de Alzheimer/metabolismo , Impedância Elétrica , Ouro/farmacologia , Astrócitos/metabolismo , Peptídeos beta-Amiloides/metabolismo , Endotélio/metabolismo , Permeabilidade , Dispositivos Lab-On-A-Chip
2.
Clin Transplant ; 36(3): e14550, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34851532

RESUMO

Multicenter, prospective, observational study to compare the relative bioavailability of once-daily tacrolimus formulations in de novo kidney transplant recipients. De novo kidney transplant recipients who started a tacrolimus-based regimen were included 14 days post-transplant and followed up for 6 months. Data from 218 participants were evaluated: 129 in the LCPT group (Envarsus) and 89 in the PR-Tac (Advagraf) group. Patients in the LCPT group exhibited higher relative bioavailability (Cmin /total daily dose [TDD]) vs. PR-Tac (61% increase; P < .001) with similar Cmin and 30% lower TDD levels (P < .0001). The incidence of treatment failure was 3.9% in the LCPT group and 9.0% in the PR-Tac group (P = .117). Study discontinuation rates were 6.2% in the LCPT group and 12.4% in the PR-Tac group (P = .113). Adverse events, renal function and other complications were comparable between groups. The median accumulated dose of tacrolimus in the LCPT group from day 14 to month 6 was 889 mg. Compared to PR-Tac, LCPT showed higher relative bioavailability, similar effectiveness at preventing allograft rejection, comparable effect on renal function, safety, adherence, treatment failure and premature discontinuation rates.


Assuntos
Transplante de Rim , Tacrolimo , Disponibilidade Biológica , Esquema de Medicação , Rejeição de Enxerto/tratamento farmacológico , Rejeição de Enxerto/etiologia , Rejeição de Enxerto/prevenção & controle , Humanos , Imunossupressores/uso terapêutico , Transplante de Rim/efeitos adversos , Estudos Prospectivos , Tacrolimo/uso terapêutico , Transplantados
3.
J Transl Med ; 19(1): 53, 2021 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-33541374

RESUMO

BACKGROUND: One of the most prevalent causes of fetal hypoxia leading to stillbirth is placental insufficiency. Hemodynamic changes evaluated with Doppler ultrasound have been used as a surrogate marker of fetal hypoxia. However, Doppler evaluation cannot be performed continuously. As a first step, the present work aimed to evaluate the performance of miniaturized electrochemical sensors in the continuous monitoring of oxygen and pH changes in a model of acute hypoxia-acidosis. METHODS: pH and oxygen electrochemical sensors were evaluated in a ventilatory hypoxia rabbit model. The ventilator hypoxia protocol included 3 differential phases: basal (100% FiO2), the hypoxia-acidosis period (10% FiO2) and recovery (100% FiO2). Sensors were tested in blood tissue (ex vivo sensing) and in muscular tissue (in vivo sensing). pH electrochemical and oxygen sensors were evaluated on the day of insertion (short-term evaluation) and pH electrochemical sensors were also tested after 5 days of insertion (long-term evaluation). pH and oxygen sensing were registered throughout the ventilatory hypoxia protocol (basal, hypoxia-acidosis, and recovery) and were compared with blood gas metabolites results from carotid artery catheterization (obtained with the EPOC blood analyzer). Finally, histological assessment was performed on the sensor insertion site. One-way ANOVA was used for the analysis of the evolution of acid-based metabolites and electrochemical sensor signaling results; a t-test was used for pre- and post-calibration analyses; and chi-square analyses for categorical variables. RESULTS: At the short-term evaluation, both the pH and oxygen electrochemical sensors distinguished the basal and hypoxia-acidosis periods in both the in vivo and ex vivo sensing. However, only the ex vivo sensing detected the recovery period. In the long-term evaluation, the pH electrochemical sensor signal seemed to lose sensibility. Finally, histological assessment revealed no signs of alteration on the day of evaluation (short-term), whereas in the long-term evaluation a sub-acute inflammatory reaction adjacent to the implantation site was detected. CONCLUSIONS: Miniaturized electrochemical sensors represent a new generation of tools for the continuous monitoring of hypoxia-acidosis, which is especially indicated in high-risk pregnancies. Further studies including more tissue-compatible material would be required in order to improve long-term electrochemical sensing.


Assuntos
Acidose , Oxigênio , Animais , Feminino , Concentração de Íons de Hidrogênio , Hipóxia , Modelos Animais , Gravidez , Coelhos
4.
Clin Transplant ; 35(5): e14256, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33599030

RESUMO

BACKGROUND: The use of mycophenolic acid (MPA) in women during pregnancy causes an increase in miscarriages and birth defects with a typical embryopathy profile. Although epidemiological data does not suggest a greater risk among the offspring of male kidney transplant recipients, the European Medicines Agency and The Spanish Agency of Medicines and Medical Devices introduced the recommendation of using contraceptive methods. METHODS: We conducted a national retrospective study in 15 Spanish Kidney Transplant Centers to evaluate the frequency of miscarriages and birth defects between the offspring from male kidney transplants recipients. We included 151 males who had fathered 239 offspring, 225 under MPA and 14 without MPA. RESULTS: The results of our study showed an incidence of miscarriages in the MPA group of 9.8%, and of birth defects of 4%. CONCLUSIONS: We observed an incidence of miscarriages between the offspring fathered by kidney transplant males under MPA lower than the general population. The incidence of birth defects was similar to the incidence described in other studies and the fact that we did not find the typical embryopathy profile makes it difficult to associate them to the use of MPA. Because of that, we urge the European and Spanish Agencies to reconsider their recommendations for males.


Assuntos
Transplante de Rim , Ácido Micofenólico , Feminino , Humanos , Imunossupressores , Masculino , Gravidez , Estudos Retrospectivos , Comprimidos com Revestimento Entérico , Transplantados
5.
Sensors (Basel) ; 20(5)2020 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-32121271

RESUMO

Cancer represents one of the conditions with the most causes of death worldwide. Common methods for its diagnosis are based on tissue biopsies-the extraction of tissue from the primary tumor, which is used for its histological analysis. However, this technique represents a risk for the patient, along with being expensive and time-consuming and so it cannot be frequently used to follow the progress of the disease. Liquid biopsy is a new cancer diagnostic alternative, which allows the analysis of the molecular information of the solid tumors via a body fluid draw. This fluid-based diagnostic method displays relevant advantages, including its minimal invasiveness, lower risk, use as often as required, it can be analyzed with the use of microfluidic-based platforms with low consumption of reagent, and it does not require specialized personnel and expensive equipment for the diagnosis. In recent years, the integration of sensors in microfluidics lab-on-a-chip devices was performed for liquid biopsies applications, granting significant advantages in the separation and detection of circulating tumor nucleic acids (ctNAs), circulating tumor cells (CTCs) and exosomes. The improvements in isolation and detection technologies offer increasingly sensitive and selective equipment's, and the integration in microfluidic devices provides a better characterization and analysis of these biomarkers. These fully integrated systems will facilitate the generation of fully automatized platforms at low-cost for compact cancer diagnosis systems at an early stage and for the prediction and prognosis of cancer treatment through the biomarkers for personalized tumor analysis.


Assuntos
Detecção Precoce de Câncer/métodos , Biópsia Líquida/métodos , Microfluídica/métodos , Biomarcadores Tumorais/sangue , Ácidos Nucleicos Livres/sangue , Exossomos/patologia , Humanos , Dispositivos Lab-On-A-Chip , Células Neoplásicas Circulantes/patologia
6.
Int J Mol Sci ; 19(10)2018 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-30248975

RESUMO

Cancer is one of the greatest threats facing our society, being the second leading cause of death globally. Currents strategies for cancer diagnosis consist of the extraction of a solid tissue from the affected area. This sample enables the study of specific biomarkers and the genetic nature of the tumor. However, the tissue extraction is risky and painful for the patient and in some cases is unavailable in inaccessible tumors. Moreover, a solid biopsy is expensive and time consuming and cannot be applied repeatedly. New alternatives that overcome these drawbacks are rising up nowadays, such as liquid biopsy. A liquid biopsy is the analysis of biomarkers in a non-solid biological tissue, mainly blood, which has remarkable advantages over the traditional method; it has no risk, it is non-invasive and painless, it does not require surgery and reduces cost and diagnosis time. The most studied cancer non-invasive biomarkers are circulating tumor cells (CTCs), circulating tumor DNA (ctDNA), and exosomes. These circulating biomarkers play a key role in the understanding of metastasis and tumorigenesis, which could provide a better insight into the evolution of the tumor dynamics during treatment and disease progression. Improvements in isolation technologies, based on a higher grade of purification of CTCs, exosomes, and ctDNA, will provide a better characterization of biomarkers and give rise to a wide range of clinical applications, such as early detection of diseases, and the prediction of treatment responses due to the discovery of personalized tumor-related biomarkers.


Assuntos
Biomarcadores Tumorais/sangue , Biópsia/métodos , Biópsia Líquida/métodos , Humanos , Células Neoplásicas Circulantes/metabolismo
7.
Electrophoresis ; 38(21): 2712-2720, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28504351

RESUMO

Nanogap electrodes have attracted a lot of consideration as promising platform for molecular electronic and biomolecules detection. This is mainly for their higher aspect ratio, and because their electrical properties are easily accessed by current-voltage measurements. Nevertheless, application of standard current-voltages measurements used to characterize nanogap response, and/or to modify specific nanogap electrodes properties, represents an issue. Since the strength of electrical fields in nanoscaled devices can reach high values, even at low voltages. Here, we analyzed the effects induced by different methods of surface modification of nanogap electrodes, in test-voltage application, employed for the electrical detection of a desoxyribonucleic acid (DNA) target. Nanogap electrodes were functionalized with two antisymmetric oligo-probes designed to have 20 terminal bases complementary to the edges of the target, which after hybridization bridges the nanogap, closing the electrical circuit. Two methods of functionalization were studied for this purpose; a random self-assembling of a mixture of the two oligo-probes (OPs) used in the platform, and a selective method that controls the position of each OP at selected side of nanogap electrodes. We used for this aim, the electrophoretic effect induced on negatively charged probes by the application of an external direct current voltage. The results obtained with both functionalization methods where characterized and compared in terms of electrode surface covering, calculated by using voltammetry analysis. Moreover, we contrasted the electrical detection of a DNA target in the nanogap platform either in site-selective and in randomly assembled nanogap. According to our results, a denser, although not selective surface functionalization, is advantageous for such kind of applications.


Assuntos
Técnicas Biossensoriais/instrumentação , DNA/análise , Nanoestruturas/química , Sondas de Oligonucleotídeos/química , Técnicas Eletroquímicas/instrumentação , Eletrodos , Campos Eletromagnéticos , Eletroforese/instrumentação , Ouro/química , Humanos , Nanotecnologia , Dióxido de Silício/química , Propriedades de Superfície , Titânio/química
8.
Nanotechnology ; 28(13): 135702, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28151432

RESUMO

Carbon nanotubes (CNTs) have been the subject of many studies due to their unique structure and desirable properties. However, the ability to solubilize and separate single CNTs from the bundles they form is still a challenge that needs to be overcome in order to extend their applications in the field of Nanotechnology. Covalent interactions are designed to modify CNTs surface and so prevent agglomeration. Though, this method alters the structures and intrinsic properties of CNTs. In the present work, noncovalent approaches to functionalize and solubilize CNTs are studied in detail. A dispersion kinetic study was performed to characterize the ability of different type of surfactants (non-ionic, anionic, cationic and biopolymer) to unzip CNT bundles. The dispersion kinetic study performed depicts the distinct CNTs bundles unzipping behavior of the different type of surfactants and the results elucidate specific wavelengths in relation with the degree of CNT clustering, which provides new tools for a deeper understanding and characterization of CNTs. Small angle x-ray scattering and transmission electron microscopy results are in agreement with UV-vis-NIR observations, revealing perfectly monodispersed CNTs for the biopolymer and cationic surfactant.

9.
Nanotechnology ; 27(46): 465102, 2016 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-27734811

RESUMO

The accumulation of iron oxides-mainly magnetite-with amyloid peptide is a key process in the development of Alzheimer's disease (AD). However, the mechanism for biogeneration of magnetite inside the brain of someone with AD is still unclear. The iron-storing protein ferritin has been identified as the main magnetite-storing molecule. However, accumulations of magnetite in AD are not correlated with an increase in ferritin, leaving this question unresolved. Here we demonstrate the key role of amyloid peptide Aß 42, one of the main hallmarks of AD, in the generation of magnetite nanoparticles in the absence of ferritin. The capacity of amyloid peptide to bind and concentrate iron hydroxides, the basis for the formation of magnetite, benefits the spontaneous synthesis of these nanoparticles, even under unfavorable conditions for their formation. Using scanning and transmission electron microscopy, electron energy loss spectroscopy and magnetic force microscopy we characterized the capacity of amyloid peptide Aß 42 to promote magnetite formation.


Assuntos
Nanopartículas de Magnetita , Doença de Alzheimer , Amiloide , Peptídeos beta-Amiloides , Óxido Ferroso-Férrico
10.
Electrophoresis ; 36(16): 1905-11, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25999089

RESUMO

The ability of holding back the undesired molecules, but at the same time to provide the right distribution and orientation of the bioreceptors, are critical targets to reach an efficient hybridization and enhanced detection in electrochemical DNA biosensors. The main actors responsible of these key functions are the substrate of the sensor and the interface auto-assembled on it. In this paper we present the annealing as a method to improve commercial gold evaporated substrates for biosensor applications. The restructuring of granulated gold surface by means of annealing heating treatment leads to the formation of ultraflat gold lamellar terraces. The formation of terraces was characterized with scanning tunneling microscopy and optical interferometry. The performance of the sensor sensitivity on granular substrates and ultraflat substrates was studied, concerning the orientation and surface coverage of the bioreceptor interface applied in electrochemical biosensor. The hybridization efficiency of ferrocene-labeled DNA amplified by PCR was characterized with surface plasmon resonance and electrochemistry. The experimental results demonstrate that annealing process, positive influence on optical and voltammetric readings, due to a structured organization of the bioreceptors on the flat substrate, gaining more efficient immobilization and DNA hybridization. The results suggest the annealing as a powerful tool for improving gold substrates in biosensors applications.


Assuntos
Técnicas Biossensoriais/instrumentação , DNA/química , Técnicas Eletroquímicas/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Hibridização de Ácido Nucleico , Propriedades de Superfície
11.
Sensors (Basel) ; 14(7): 11844-54, 2014 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-24999717

RESUMO

Poly(vinylchloride) (PVC) is the most common polymer matrix used in the fabrication of ion-selective electrodes (ISEs). However, the surfaces of PVC-based sensors have been reported to show membrane instability. In an attempt to overcome this limitation, here we developed two alternative methods for the preparation of highly stable and robust ion-selective sensors. These platforms are based on the selective electropolymerization of poly(3,4-ethylenedioxythiophene) (PEDOT), where the sulfur atoms contained in the polymer covalently interact with the gold electrode, also permitting controlled selective attachment on a miniaturized electrode in an array format. This platform sensor was improved with the crosslinking of the membrane compounds with poly(ethyleneglycol) diglycidyl ether (PEG), thus also increasing the biocompatibility of the sensor. The resulting ISE membranes showed faster signal stabilization of the sensor response compared with that of the PVC matrix and also better reproducibility and stability, thus making these platforms highly suitable candidates for the manufacture of robust implantable sensors.


Assuntos
Materiais Biocompatíveis/química , Compostos Bicíclicos Heterocíclicos com Pontes/química , Eletrodos Implantados , Eletrodos Seletivos de Íons , Membranas Artificiais , Análise em Microsséries/instrumentação , Polietilenoglicóis/química , Polímeros/química , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Miniaturização
12.
Sensors (Basel) ; 14(7): 11416-26, 2014 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-24971473

RESUMO

Here we have developed a simple method for the fabrication of disposable implantable all-solid-state ion-selective electrodes (ISE) in an array format without using complex fabrication equipment or clean room facilities. The electrodes were designed in a needle shape instead of planar electrodes for a full contact with the tissue. The needle-shape platform comprises 12 metallic pins which were functionalized with conductive inks and ISE membranes. The modified microelectrodes were characterized with cyclic voltammetry, scanning electron microscope (SEM), and optical interferometry. The surface area and roughness factor of each microelectrode were determined and reproducible values were obtained for all the microelectrodes on the array. In this work, the microelectrodes were modified with membranes for the detection of pH and nitrate ions to prove the reliability of the fabricated sensor array platform adapted to an endoscope.


Assuntos
Condutometria/instrumentação , Equipamentos Descartáveis , Eletrodos Implantados , Endoscópios , Endoscopia/instrumentação , Endoscopia/métodos , Análise em Microsséries/instrumentação , Condutometria/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Análise em Microsséries/métodos , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos , Transdutores
13.
Lab Chip ; 24(7): 2094-2106, 2024 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-38444329

RESUMO

Organ-on-chip (OOC) technology has recently emerged as a powerful tool to mimic physiological or pathophysiological conditions through cell culture in microfluidic devices. One of its main goals is bypassing animal testing and encouraging more personalized medicine. The recent incorporation of hydrogels as 3D scaffolds into microfluidic devices has changed biomedical research since they provide a biomimetic extracellular matrix to recreate tissue architectures. However, this technology presents some drawbacks such as the necessity for physical structures as pillars to confine these hydrogels, as well as the difficulty in reaching different shapes and patterns to create convoluted gradients or more realistic biological structures. In addition, pillars can also interfere with the fluid flow, altering the local shear forces and, therefore, modifying the mechanical environment in the OOC model. In this work, we present a methodology based on a plasma surface treatment that allows building cell culture chambers with abutment-free patterns capable of producing precise shear stress distributions. Therefore, pillarless devices with arbitrary geometries are needed to obtain more versatile, reliable, and biomimetic experimental models. Through computational simulation studies, these shear stress changes are demonstrated in different designed and fabricated geometries. To prove the versatility of this new technique, a blood-brain barrier model has been recreated, achieving an uninterrupted endothelial barrier that emulates part of the neurovascular network of the brain. Finally, we developed a new technology that could avoid the limitations mentioned above, allowing the development of biomimetic OOC models with complex and adaptable geometries, with cell-to-cell contact if required, and where fluid flow and shear stress conditions could be controlled.


Assuntos
Técnicas de Cultura de Células , Hidrogéis , Animais , Hidrogéis/química , Endotélio , Matriz Extracelular/química , Dispositivos Lab-On-A-Chip
14.
Nanomaterials (Basel) ; 13(19)2023 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-37836338

RESUMO

Alzheimer's disease is characterized by a combination of several neuropathological hallmarks, such as extracellular aggregates of beta amyloid (Aß). Numerous alternatives have been studied for inhibiting Aß aggregation but, at this time, there are no effective treatments available. Here, we developed the tri-component nanohybrid system AuNPs@POM@PEG based on gold nanoparticles (AuNPs) covered with polyoxometalates (POMs) and polyethylene glycol (PEG). In this work, AuNPs@POM@PEG demonstrated the inhibition of the formation of amyloid fibrils, showing a 75% decrease in Aß aggregation in vitro. As it is a potential candidate for the treatment of Alzheimer's disease, we evaluated the cytotoxicity of AuNPs@POM@PEG and its ability to cross the blood-brain barrier (BBB). We achieved a stable nanosystem that is non-cytotoxic below 2.5 nM to human neurovascular cells. The brain permeability of AuNPs@POM@PEG was analyzed in an in vitro microphysiological model of the BBB (BBB-on-a-chip), containing 3D human neurovascular cell co-cultures and microfluidics. The results show that AuNPs@POM@PEG was able to cross the brain endothelial barrier in the chip and demonstrated that POM does not affect the barrier integrity, giving the green light to further studies into this system as a nanotherapeutic.

15.
Nanoscale ; 15(17): 7929-7944, 2023 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-37067009

RESUMO

A hydroxycinnamic acid derivative, namely ferulic acid (FA) has been successfully encapsulated in polymeric nanoparticles (NPs) based on poly(lactic-co-glycolic acid) (PLGA). FA-loaded polymeric NPs were prepared from O/W nano-emulsion templates using the phase inversion composition (PIC) low-energy emulsification method. The obtained PLGA NPs exhibited high colloidal stability, good drug-loading capacity, and particle hydrodynamic diameters in the range of 74 to 117 nm, depending on the FA concentration used. In vitro drug release studies confirmed a diffusion-controlled mechanism through which the amount of released FA reached a plateau at 60% after 6 hours-incubation. Five kinetic models were used to fit the FA release data as a function of time. The Weibull distribution and Korsmeyer-Peppas equation models provided the best fit to our experimental data and suggested quasi-Fickian diffusion behaviour. Moderate dose-response antioxidant and radical scavenging activities of FA-loaded PLGA NPs were demonstrated using the DPPH˙ assay achieving inhibition activities close to 60 and 40%, respectively. Cell culture studies confirmed that FA-loaded NPs were not toxic according to the MTT colorimetric assay, were able to internalise efficiently SH-SY5Y neuronal cells and supressed the intracellular ROS-level induced by H2O2 leading to 52% and 24.7% of cellular viability at 0.082 and 0.041 mg mL-1, respectively. The permeability of the NPs through the blood brain barrier was tested with an in vitro organ-on-a-chip model to evaluate the ability of the FA-loaded PLGA and non-loaded PLGA NPs to penetrate to the brain. NPs were able to penetrate the barrier, but permeability decreased when FA was loaded. These results are promising for the use of loaded PLGA NPs for the management of neurological diseases.


Assuntos
Nanopartículas , Neuroblastoma , Humanos , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Ácidos Cumáricos/farmacologia , Ácido Poliglicólico , Ácido Láctico , Barreira Hematoencefálica , Peróxido de Hidrogênio , Tamanho da Partícula , Portadores de Fármacos/farmacologia
16.
Nanomedicine ; 8(6): 974-80, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22115601

RESUMO

Biogenic magnetite (Fe(3)O(4)) has been identified in human brain tissue. However, abnormal concentration of magnetite nanoparticles in the brain has been observed in different neurodegenerative pathologies. In the case of Alzheimer's disease (AD), these magnetic nanoparticles have been identified attached to the characteristic brain plaques, which are mainly formed by fibrils of amyloid ß peptide (Aß). However, few clues about the formation of the magnetite-Aß complex have been reported. We have investigated the interaction between these important players in AD with superconducting quantum interference, scanning electron microscope, surface plasmon resonance, and magnetic force microscopy. The results support the notion that the magnetite-Aß complex is created before the synthesis of the magnetic nanoparticles, bringing a highly stable interaction of this couple. .


Assuntos
Peptídeos beta-Amiloides/química , Peptídeos beta-Amiloides/ultraestrutura , Nanopartículas de Magnetita/química , Nanopartículas de Magnetita/ultraestrutura , Sítios de Ligação , Teste de Materiais , Tamanho da Partícula , Ligação Proteica , Propriedades de Superfície
17.
ACS Sens ; 7(5): 1237-1247, 2022 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-35559649

RESUMO

Over the most recent decades, the development of new biological platforms to study disease progression and drug efficacy has been of great interest due to the high increase in the rate of neurodegenerative diseases (NDDs). Therefore, blood-brain barrier (BBB) as an organ-on-a-chip (OoC) platform to mimic brain-barrier performance could offer a deeper understanding of NDDs as well as a very valuable tool for drug permeability testing for new treatments. A very attractive improvement of BBB-oC technology is the integration of detection systems to provide continuous monitoring of biomarkers in real time and a fully automated analysis of drug permeably, rendering more efficient platforms for commercialization. In this Perspective, an overview of the main BBB-oC configurations is introduced and a critical vision of the BBB-oC platforms integrating electronic read out systems is detailed, indicating the strengths and weaknesses of current devices, proposing the great potential for biosensors integration in BBB-oC. In this direction, we name potential biomarkers to monitor the evolution of NDDs related to the BBB and/or drug cytotoxicity using biosensor technology in BBB-oC.


Assuntos
Técnicas Biossensoriais , Doenças Neurodegenerativas , Barreira Hematoencefálica , Encéfalo , Humanos , Dispositivos Lab-On-A-Chip , Doenças Neurodegenerativas/diagnóstico
18.
Transplant Proc ; 54(1): 80-86, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34911620

RESUMO

BACKGROUND: Neurotoxicity secondary to anticalcineurinics is a prevalent side effect in transplant recipients. Optical coherence tomography (OCT) scans the central nervous system by direct access to the retina. OCT assesses central nervous system involvement by measuring the thickness of the retinal layers, especially the ganglion cell layer (GCL). The retinal scan divides the scanned area into affected and unaffected segments, which can be quantified for each eye. The aim of this study was to determine retinal GCL thickness by means of OCT, analyzing the proportion of affected segments in individuals exposed to tacrolimus compared with a control group. MATERIALS AND METHODS: We evaluated 20 renal transplant recipients exposed to tacrolimus for ≥6 months. The number of affected segments in the GCL of the retina was quantified by OCT. The control group was drawn from the general population attending routine ophthalmologic checkups. RESULTS: Patients exposed to tacrolimus had a pathologic examination in 50% of cases compared with 20% in the control group (P < .044). Furthermore, among patients with an exposure time to tacrolimus >5 years, the examination was pathologic in 80% (P < .005). Linear regression analysis showed the presence of GCL segments with decreased thickness to be associated with the duration of exposure to tacrolimus (P = .036) and the time in dialysis before kidney transplant (P = .030). CONCLUSION: Although this is a preliminary study, OCT scanning could serve to detect the neurotoxic effect of tacrolimus on the retinal GCL and central nervous system in renal transplant recipients.


Assuntos
Tacrolimo , Tomografia de Coerência Óptica , Humanos , Diálise Renal , Retina/diagnóstico por imagem , Células Ganglionares da Retina , Tacrolimo/efeitos adversos
19.
Electrophoresis ; 32(8): 811-21, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21425177

RESUMO

Electrokinetic techniques are contact-free methods currently used in many applications, where precise handling of biological entities, such as cells, bacteria or nucleic acids, is needed. These techniques are based on the effect of electric fields on molecules suspended in a fluid, and the corresponding induced motion, which can be tuned according to some known physical laws and observed behaviours. Increasing interest on the application of such strategies in order to improve the detection of DNA strands has appeared during the recent decades. Classical electrode-based DNA electrochemical biosensors with combined electrokinetic techniques present the advantage of being able to improve the working electrode's bioactive part during their fabrication and also the hybridization yield during the sensor detection phase. This can be achieved by selectively manipulating, driving and directing the molecules towards the electrodes increasing the speed and yield of the floating DNA strands attached to them. On the other hand, this technique can be also used in order to make biosensors reusable, or reconfigurable, by simply inverting its working principle and pulling DNA strands away from the electrodes. Finally, the combination of these techniques with nanostructures, such as nanopores or nanochannels, has recently boosted the appearance of new types of electrochemical sensors that exploit the time-varying position of DNA strands in order to continuously scan these molecules and to detect their properties. This review gives an insight into the main forces involved in DNA electrokinetics and discusses the state of the art and uses of these techniques in recent years.


Assuntos
Técnicas Biossensoriais/métodos , DNA/análise , Técnicas Eletroquímicas/métodos , Dispositivos Lab-On-A-Chip , Algoritmos , DNA/química , DNA/isolamento & purificação , Nanoporos , Viscosidade
20.
Talanta ; 225: 121898, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33592692

RESUMO

The current situation of the Covid-19 pandemic is indicated by a huge number of infections, high lethality, and rapid spread. These circumstances have stopped the activity of almost the entire world, affecting severely the global economy. A rapid diagnosis of the Covid-19 and a generalized testing protocol is essential to fight against the pandemic and to maintain health control in the population. Principal biosensing and diagnostic technologies used to monitor the spread of the SARS-CoV-2 are based on specific genomic analysis and rapid immune tests, both with different technology platforms that include advantages and disadvantages. Most of the in vitro diagnosis companies are competing to be the first on validating under different regulations their technology for placing their platforms for Covid-19 detection as fast as possible in this big international market. A comprehensive analysis of the commercialized technologies for the genomic based sensing and the antibody/antigen detection methods devoted to Covid-19 diagnosis is described in this review, which have been detailed and listed under different countries regulations. The effectiveness of the described technologies throughout the different stages of the disease and a critical comparison of the emerging technologies in the market to counterattack this pandemic have been discussed.


Assuntos
COVID-19/diagnóstico , Imunoensaio/métodos , Técnicas de Diagnóstico Molecular/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , SARS-CoV-2/isolamento & purificação , Anticorpos Antivirais/imunologia , Antígenos Virais/imunologia , COVID-19/epidemiologia , COVID-19/virologia , Humanos , Pandemias , SARS-CoV-2/genética , SARS-CoV-2/fisiologia , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA