Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 146
Filtrar
1.
Int J Mol Sci ; 25(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38612777

RESUMO

High-grade gliomas (HGGs) and glioblastoma multiforme (GBM) are characterized by a heterogeneous and aggressive population of tissue-infiltrating cells that promote both destructive tissue remodeling and aberrant vascularization of the brain. The formation of defective and permeable blood vessels and microchannels and destructive tissue remodeling prevent efficient vascular delivery of pharmacological agents to tumor cells and are the significant reason why therapeutic chemotherapy and immunotherapy intervention are primarily ineffective. Vessel-forming endothelial cells and microchannel-forming glial cells that recapitulate vascular mimicry have both infiltration and destructive remodeling tissue capacities. The transmembrane protein TMEM230 (C20orf30) is a master regulator of infiltration, sprouting of endothelial cells, and microchannel formation of glial and phagocytic cells. A high level of TMEM230 expression was identified in patients with HGG, GBM, and U87-MG cells. In this study, we identified candidate genes and molecular pathways that support that aberrantly elevated levels of TMEM230 play an important role in regulating genes associated with the initial stages of cell infiltration and blood vessel and microchannel (also referred to as tumor microtubule) formation in the progression from low-grade to high-grade gliomas. As TMEM230 regulates infiltration, vascularization, and tissue destruction capacities of diverse cell types in the brain, TMEM230 is a promising cancer target for heterogeneous HGG tumors.


Assuntos
Glioblastoma , Glioma , Doença de Parkinson , Humanos , Glioblastoma/genética , Proteínas de Membrana/genética , Células Endoteliais , Angiogênese , Glioma/genética , Neuroglia , Neovascularização Patológica/genética
2.
J Endovasc Ther ; : 15266028231177047, 2023 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-37271989

RESUMO

AIM: We present a case of successful endovascular repair of late ruptured aortic anastomotic pseudoaneurysm following previous left subclavian artery-descending thoracic aorta bypass and concomitant emergency thoracic endovascular aortic repair (TEVAR) of complicated endovascular aortic de-coarctation never previously described is also presented. A review of the intraoperative, 30-day, and follow-up morbidity, mortality, and complications of TEVAR as endovascular treatment of late aneurysm/pseudoaneurysms after surgical aortic de-coarctation was also performed. METHODS: The systematic review was performed in accordance with the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) statement and following PICO model. A literature search was conducted on MEDLINE, PubMed, EMBASE, Cochrane Library, Google Scholar, Science Direct, and Web of Science using the words "tevar of late complication of aortic coarctation surgical repair" and "endovascular repair of anastomotic pseudoaneurysm in coarctation" up to June 17, 2022. Data were extracted from study documents about study design, patient's demographics and comorbidities, details about primary surgical repair, type of late complication, time between open surgery and occurrence of complications, details of the secondary endovascular procedure with technical success, early, and follow-up mortality and morbidity. RESULTS: A total of 18 papers were included with 78 patients (48 men, 69.5%). The most frequent type of primary open surgical repair was patch aortoplasty (46, 58.9%). Focusing on aneurysm and pseudoaneurysm as late complications, most of the patients were asymptomatic (45, 57.7%). All patients underwent TEVAR, 14 of them (17.9%) in urgent/emergent setting. The technical success was 98.7%, with 1 intraoperative death due to rupture of the aorta. In total, 31 patients out of 78 (39.7%) showed different complications in the immediate postoperative time, with type II endoleak being the most observed (8/31, 25.8%). The mean follow-up time was about 2 years (26.5 months, range 3-92). Overall, 30-day mortality was 2.6%. Complications occurred in 30 patients (39.4%), 23 of them resolved during the follow-up period. CONCLUSIONS: With the limit of low-quality data, TEVAR can be considered a safe and effective option for the treatment of late complications after open surgery for aortic coarctation, even in urgent settings. CLINICAL IMPACT: Different specialists have to face the technical complexities and risks related to treatment of late complications after surgical de-coartaction, which can be either surgical or endovascular, and depend on patient's ages. Although covered stents appear to have some protection from the development of stent fractures, doesn't provide complete protection from late aneurysm formation. In this setting, TEVAR may represent a valuable option, combining the advantages of the covered stent with those of a device that can cover a wider range of aortic length, especially in adult patients. This study shows thoracic endovascular repair can be considered a safe and effective option in clincal practice for the treatment of late complications after open surgery for AC, even in urgent settings.

3.
J Endovasc Ther ; 30(5): 756-768, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-35588222

RESUMO

PURPOSE: Displacement forces (DFs) identify hostile landing zones for stent graft deployment in thoracic endovascular aortic repair (TEVAR). However, their use in TEVAR planning is hampered by the need for time-expensive computational fluid dynamics (CFD). We propose a novel fast-approximate computation of DFs merely exploiting aortic arch anatomy, as derived from the computed tomography (CT) and a measure of central aortic pressure. MATERIALS AND METHODS: We tested the fast-approximate approach against CFD gold-standard in 34 subjects with the "bovine" aortic arch variant. For each dataset, a 3-dimensional (3D) model of the aortic arch lumen was reconstructed from computed tomography angiography and CFD then employed to compute DFs within the aortic proximal landing zones. To quantify fast-approximate DFs, the wall shear stress contribution to the DF was neglected and blood pressure space-distribution was averaged on the entire aortic wall to reliably approximate the patient-specific central blood pressure. Also, DF values were normalized on the corresponding proximal landing zone area to obtain the equivalent surface traction (EST). RESULTS: Fast-approximate approach consistently reflected (r2=0.99, p<0.0001) the DF pattern obtained by CFD, with a -1.1% and 0.7° bias in DFs magnitude and orientation, respectively. The normalized EST progressively increased (p<0.0001) from zone 0 to zone 3 regardless of the type of arch, with proximal landing zone 3 showing significantly greater forces than zone 2 (p<0.0001). Upon DF normalization to the corresponding aortic surface, fast-approximate EST was decoupled in blood pressure and a dimensionless shape vector (S) reflecting aortic arch morphology. S showed a zone-specific pattern of orientation and proved a valid biomechanical blueprint of DF impact on the thoracic aortic wall. CONCLUSION: Requiring only a few seconds and quantifying clinically relevant biomechanical parameters of proximal landing zones for arch TEVAR, our method suits the real preoperative decision-making process. It paves the way toward analyzing large population of patients and hence to define threshold values for a future patient-specific preoperative TEVAR planning.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Resultado do Tratamento , Stents
4.
Ann Vasc Surg ; 93: 252-260, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36739080

RESUMO

BACKGROUND: To compare the outcomes of patients who were submitted to partial carotid endarterectomy (P-CEA) to those of patients who underwent standard conventional CEA with patch closure (C-CEA) and eversion CEA (E-CEA) for a significant carotid stenosis. METHODS: Data of patients who consecutively underwent CEA from January 2014 to December 2018 for a significant carotid stenosis were retrospectively collected. Primary outcomes included mortality and the occurrence of neurologic and cardiologic complications, both at 30 days and during follow-up. Secondary outcomes included the occurrence of perioperative local complications (i.e. cranial nerve injuries, hematomas) and restenosis during follow-up. P values < 0.5 were considered statistically significant. RESULTS: Three-hundred twenty-seven patients (241 males, 74%) underwent CEA for carotid stenosis (28.6% symptomatic). P-CEA was performed in 202 patients (61.8%), while C-CEA and E-CEA were performed in 103 and 22 cases respectively. At 30 days, neurologic complications were not significantly different among the 3 groups (2.8% in the group of C-CEA, 2.4% after P-CEA and 0% in E-CEA patients, P = 0.81), neither during follow-up. Perioperative local complications also were not significantly different among the 3 groups (P = 0.16). CONCLUSIONS: P-CEA had similar outcomes if compared to C-CEA and to E-CEA in terms of perioperative mortality, occurrence of neurologic and cardiologic complications, and occurrence of local complications. Also, in the long-term, P-CEA, C-CEA, and E-CEA were burdened by similar rates of mortality, neurologic, and cardiologic complications and restenosis.


Assuntos
Estenose das Carótidas , Endarterectomia das Carótidas , Acidente Vascular Cerebral , Masculino , Humanos , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Constrição Patológica/etiologia , Recidiva , Acidente Vascular Cerebral/complicações , Fatores de Risco
5.
Ann Vasc Surg ; 90: 128-136, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36270550

RESUMO

BACKGROUNDS: Resistance to the pharmacological effect of clopidogrel in patients undergoing dual antiplatelet therapy for carotid stenting may increase the risk of periprocedural neurological events. The purpose of the study was to describe the phenomenon of clopidogrel resistance in a series of patients undergoing carotid stenting. METHODS: Data of patients who consecutively underwent carotid stenting from November 2016 to December 2020 for a significant stenosis and who underwent a dual antiplatelet therapy using acetyl-salicylic acid and clopidogrel were prospectively collected. Patients who were already taking a different thienopyridine were excluded. The effectiveness of antiplatelet drugs was assessed by the impedance aggregometry test. Primary endpoint was to evaluate the incidence of clopidogrel resistance and the effectiveness of ticagrelor as alternative therapy. P values < 0.05 were considered statistically significant. RESULTS: Two-hundred patients (80 females, 40%) underwent stenting for carotid stenosis (94% asymptomatic). The phenomenon of clopidogrel resistance was observed in 38 patients (19%), in whom clopidogrel was replaced by ticagrelor (90 mg/bis in die) with 100% effectiveness at aggregometry test. Platelet counts was associated to clopidogrel resistance (P = 0.001). There was no stent thrombosis at 30 days, neither major hemorrhagic events; a total of 12/200 major adverse cardiovascular events occurred (6%), including 1 in the group of patients who took ticagrelor and 11 in group of patients under clopidogrel (2.6% versus 6.7%, P = 0.55). CONCLUSIONS: Clopidogrel was ineffective in 19% of patients undergoing carotid stenting. Platelet count seemed to affect this phenomenon. In these patients, clopidogrel was effectively replaced by ticagrelor.


Assuntos
Estenose das Carótidas , Intervenção Coronária Percutânea , Feminino , Humanos , Inibidores da Agregação Plaquetária/uso terapêutico , Clopidogrel , Ticagrelor/farmacologia , Estenose das Carótidas/terapia , Stents , Resultado do Tratamento , Artérias Carótidas
6.
J Vasc Surg ; 75(4): 1242-1252.e2, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34634415

RESUMO

OBJECTIVE: In recent years, manufacturers have developed new stent grafts with lower profiles to increase the endovascular aneurysm repair applicability. As reported by the current European Society for Vascular Surgery guidelines, long-term evaluation of such low-profile platforms is strongly recommended. This study aims to report outcomes beyond 5 years from a multicenter registry, including a real-world cohort of patients electively treated with low-profile stent grafts. METHODS: A retrospective data collection of patients who had undergone elective implantation of low-profile endograft ≤16 Fr. (Zenith LP, Ovation, Incraft) was performed in nine centers. The primary endpoint was a long-term primary clinical success. Secondary endpoints were survival rate, freedom from abdominal aortic aneurysm (AAA)-related death, freedom from type I to III endoleak, limb patency, and freedom from all reinterventions. The Kaplan-Meier curves were stratified for investigative devices. A multivariate analysis evaluated predictors of primary clinical success and reintervention rate. RESULTS: A total of 619 patients were enrolled (Ovation, n = 373; Incraft, n = 111; and Zenith LP, n = 135), with a mean follow-up of 56.8 ± 22.8 months. The overall primary and the secondary clinical success rate at 8 years was 72.1% and 93.8%, respectively. At 8 years, overall survival was 53.2%, freedom from AAA-related death was 94.4%, freedom from reintervention was 74%, freedom from type I/III endoleak was 86.9%, and limb patency was 90.4%. A significantly worse primary clinical success of the Zenith LP was recorded as dependent on more limb-related events. No differences between platforms were registered in the rate of AAA-related deaths, open conversion, sac enlargement, and type I/III endoleaks (P = .26). Multivariate analysis identified iliac tortuosity (hazard ratio, 2.053) and Zenith LP (hazard ratio, 3.818) as significant independent predictors of clinical failure and reintervention. CONCLUSIONS: Low-profile stent grafts have acceptable long-term outcomes. Overall survival and AAA-related death were in line with those reported for traditional devices. Long-term surveillance and reintervention, when necessary, remain crucial to guarantee durability.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Endoleak/epidemiologia , Endoleak/etiologia , Endoleak/terapia , Humanos , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Stents , Resultado do Tratamento
7.
Ann Vasc Surg ; 81: 113-120, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34743010

RESUMO

BACKGROUND: To assess the factors affecting visceral suitability of the use of the Zenith T-branchTM system in a group of patients with thoraco-adbominal aortic aneurysms (TAAAs). METHODS: Computer tomography angiography (CTA) of patients who presented a TAAA from 01/2015 to 12/2019 were retrospectively examined. Multi-Planar Reconstructions were performed on CTA images to assess the anatomic suitability of the Zenith T-branch in the visceral district. In particular, the branch deviation angle (BDA), and the branch-length were computed for each target vessel. RESULTS: Fifty-four CTA were examined. In 33.3% of these patients the presence of either a common origin of the superior mesenteric artery and the celiac trunk, or the diameter of 1 or more visceral/renal artery limited the visceral suitability of the device. All patients except 1 (97.9%) fitted the BDA criterion when the graft was placed in a position in which the BDA for the SMA was 5 degrees to the left. The branch-length criteria was met in all patients, except for 1 (97.9%), when the graft was placed in the center of the aorta. The eccentrical placement of the endograft decreased the suitability to 93.7%. CONCLUSIONS: The Zenith T-branch system can be suitable in the visceral district for about 67% of patients. The target artery diameter was the most limiting criterion. The central location of the graft within the aortic lumen significantly affected the branch-length distance criteria.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/etiologia , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/cirurgia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Humanos , Desenho de Prótese , Estudos Retrospectivos , Stents , Resultado do Tratamento
8.
Ann Vasc Surg ; 82: 325-333, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34902464

RESUMO

BACKGROUND: To investigate the presence of genetic material of viral agents and the serum level of inflammatory cytokines in patients submitted to carotid endarterectomy having vulnerable versus stable atherosclerotic plaques. METHODS: Data of patients consecutively submitted to carotid endarterectomy for a significant stenosis from July 2019 to December 2019 were prospectively collected. The genetic material of Epstein-Barr (EBV), CitoMegalo (CMV), Herpes Simplex (HSV), Varicella-Zoster (VZV) and Influenza (IV) Viruses was searched in the patient's plaques, both in the "mid" of the plaque and in an adjacent lateral portion of no-plaque area. The serum levels of TNF-α, IL-1ß, IL-6, IL10 and CCL5 were determined. The obtained results were then correlated to the histologic vulnerability of the removed carotid plaque. P values < 0.05 were considered statistically significant. RESULTS: Data of 50 patients were analyzed. A vulnerable plaque was found in 31 patients (62%). The genome of CMV, HSV, VZV and IV was not found in any of the vascular samples, while the EBV genome was found in the "mid" of 2 vulnerable plaques, but not in their respective control area. Eighty-two percent of patients who did not receive anti-IV vaccination (23/28) had vulnerable carotid plaque, compared with 36% of vaccinated patients (8/22, P = 0.001). Serum levels of TNF-α and IL-6 were higher in patients with a vulnerable plaque compared to patients with a stable plaque (73.6 ± 238.2 vs. 3.9 ± 13.1 pg/ml, P= 0.01, and 45.9 ± 103.6 vs. 10.1 ± 25.3 pg/ml, P= 0.01, respectively), independent of comorbidities, viral exposure or flu vaccination. CONCLUSIONS: The EBV genome was found in the "core" of 2 vulnerable carotid plaques, but not in their respective adjacent control. Influenza vaccination was associated with a lower incidence of carotid plaque vulnerability. Serum levels of TNF-α and IL-6 were higher in patients with a vulnerable plaque compared to patients with a stable plaque.


Assuntos
Estenose das Carótidas , Citocinas , Infecções por Citomegalovirus , Endarterectomia das Carótidas , Interleucina-6 , Placa Aterosclerótica , Fator de Necrose Tumoral alfa , Estenose das Carótidas/diagnóstico por imagem , Citocinas/sangue , Infecções por Citomegalovirus/diagnóstico , Infecções por Citomegalovirus/genética , Endarterectomia das Carótidas/efeitos adversos , Infecções por Vírus Epstein-Barr/diagnóstico , Infecções por Vírus Epstein-Barr/genética , Humanos , Inflamação/diagnóstico , Influenza Humana/diagnóstico , Influenza Humana/genética , Interleucina-6/sangue , Placa Aterosclerótica/genética , Resultado do Tratamento , Fator de Necrose Tumoral alfa/sangue
9.
Vascular ; : 17085381221081626, 2022 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-35420537

RESUMO

Although exostosis or osteochondroma is a common bone tumor, associated vascular complications are rare. Clinical and radiological diagnoses are sometimes challenging, and there is no codification for surgical management. We report two cases of popliteal arterial pseudoaneurysms due to osteochondroma of the distal femur. A review of the current literature about case series and case reports of patients affected by arterial pseudoaneurysm complicating osteochondroma was also performed.

10.
J Digit Imaging ; 35(2): 226-239, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35083618

RESUMO

Feasibility assessment and planning of thoracic endovascular aortic repair (TEVAR) require computed tomography (CT)-based analysis of geometric aortic features to identify adequate landing zones (LZs) for endograft deployment. However, no consensus exists on how to take the necessary measurements from CT image data. We trained and applied a fully automated pipeline embedding a convolutional neural network (CNN), which feeds on 3D CT images to automatically segment the thoracic aorta, detects proximal landing zones (PLZs), and quantifies geometric features that are relevant for TEVAR planning. For 465 CT scans, the thoracic aorta and pulmonary arteries were manually segmented; 395 randomly selected scans with the corresponding ground truth segmentations were used to train a CNN with a 3D U-Net architecture. The remaining 70 scans were used for testing. The trained CNN was embedded within computational geometry processing pipeline which provides aortic metrics of interest for TEVAR planning. The resulting metrics included aortic arch centerline radius of curvature, proximal landing zones (PLZs) maximum diameters, angulation, and tortuosity. These parameters were statistically analyzed to compare standard arches vs. arches with a common origin of the innominate and left carotid artery (CILCA). The trained CNN yielded a mean Dice score of 0.95 and was able to generalize to 9 pathological cases of thoracic aortic aneurysm, providing accurate segmentations. CILCA arches were characterized by significantly greater angulation (p = 0.015) and tortuosity (p = 0.048) in PLZ 3 vs. standard arches. For both arch configurations, comparisons among PLZs revealed statistically significant differences in maximum zone diameters (p < 0.0001), angulation (p < 0.0001), and tortuosity (p < 0.0001). Our tool allows clinicians to obtain objective and repeatable PLZs mapping, and a range of automatically derived complex aortic metrics.


Assuntos
Implante de Prótese Vascular , Aprendizado Profundo , Procedimentos Endovasculares , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aortografia/métodos , Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/métodos , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
11.
J Vasc Surg ; 73(4): 1277-1281, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32987147

RESUMO

OBJECTIVE: The type III arch configuration has been inconsistently reported as a stroke risk factor during carotid artery stenting. However, at least three different methods for the definition of type III arch can be identified in the literature, related to the level of the origin of the innominate artery (IA). According to Casserly's definition, a type III arch presents with an origin of the IA below the horizontal plane of the inner curvature. According to Madhwal's definition, a type III arch has a distance greater than twice the diameter of the left common carotid artery between the highest point of the arch and the origin of the IA. According to MacDonald's definition, a type III arch presents with a distance of ≥2 cm between the highest point of the arch and the origin of the IA. Our aim was to assess the level of concordance between these different methods. METHODS: Anonymized thoracic computed tomography scans of 100 healthy patients were reviewed. Two of us independently stratified the selected cases as a type I to III arch, according to the three considered definitions. The interobserver level of concordance for each type III arch classification and level of concordance among the three definitions were assessed. RESULTS: The 100 selected patients (64% male) were 76 ± 7 years old. For each definition, the interobserver repeatability was almost perfect for all three (Madhwal, κ = 0.81; 95% confidence interval [CI], 0.71-0.99; MacDonald, κ = 0.82; 95% CI, 0.72-0.92; Casserly, κ = 0.84; 95% CI, 0.74-0.93). The level of concordance among the different definitions was very low (Madhwal vs MacDonald, 85% [P = .002]; 33% for type III arch; Madhwal vs Casserly, 60% [P < .0001]; 12% for type III arch; MacDonald vs Casserly, 75% [P < .0001]; 12% for type III arch). CONCLUSIONS: The three definitions of the type III arch have a very low level of concordance, which might account for the varying clinical relevance of this configuration. Our findings have relevant implications for risk prediction for carotid artery stenting based on the presence of a type III arch, for comparisons of the results from different studies, and for comparisons of different datasets from multicenter trials.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aortografia , Doenças das Artérias Carótidas/terapia , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Stents , Malformações Vasculares/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Aorta Torácica/anormalidades , Doenças das Artérias Carótidas/complicações , Doenças das Artérias Carótidas/diagnóstico por imagem , Tomada de Decisão Clínica , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Malformações Vasculares/complicações
12.
Lupus ; 30(6): 1005-1009, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33852325

RESUMO

Catastrophic antiphospholipid syndrome (CAPS) is a life-threatening condition characterized by multiple thromboembolic events occurring in a short period of time, frequently accompanied by significant systemic inflammation. Aortic involvement is rare in antiphospholipid syndrome and it had been never described in the context of its catastrophic variant. Here, we report an unusual case of aortic occlusion as a debut manifestation of CAPS and discuss its clinical features with an up-to-date review of the literature to identify risk factors and clues for clinical practice.


Assuntos
Síndrome Antifosfolipídica/complicações , Doenças da Aorta/complicações , Artéria Ilíaca , Trombose/complicações , Amputação Cirúrgica , Anticorpos Antifosfolipídeos/análise , Síndrome Antifosfolipídica/diagnóstico , Humanos , Inibidor de Coagulação do Lúpus , Masculino , Pessoa de Meia-Idade , Trombose/terapia
13.
Catheter Cardiovasc Interv ; 96(4): E479-E483, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32681707

RESUMO

OBJECTIVE: To describe the results of the reversed bell-bottom (ReBel-B) technique for the endovascular treatment of iliac aneurysms (IA) involving the origin of hypogastric artery (HA). METHODS: The ReBel-B technique is a strategy for the occlusion of HA in selected patients presenting with IA, in whom the HA cannot be spared or safely occluded with coils or vascular plugs. When employing this technique, an iliac flared ("bell-bottom") extension is deployed in a reverse fashion, through a contralateral crossover femoral access that allows the occlusion of the HA at its origin, by exploiting the flared "bell" part of the reversed endograft. A second limb is then deployed to complete the implant, from the common iliac to the external iliac artery, inside the previous graft. Data of all consecutive patients treated with this technique in our experience were then retrospectively reviewed, and outcomes analyzed. RESULTS: The ReBel-B technique was employed in total of six patients who came in an emergent setting for the rupture of a common IA, from January 2014 to December 2018. Endovascular exclusion was performed using a ReBel-B graft plus iliac leg in five out of six cases. In the remaining case, a bifurcated aortic endograft was used to complete the aneurysm exclusion. Technical success was 100%. No complications occurred. CONCLUSIONS: In selected cases, the ReBel-B technique can be used for the complete exclusion of IA preventing type II endoleak from the HA, when the embolization with coils or plug or the preservation of the HA is anatomically unfeasible.


Assuntos
Aneurisma Roto/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco/cirurgia , Pelve/irrigação sanguínea , Idoso , Idoso de 80 Anos ou mais , Aneurisma Roto/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Masculino , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
14.
Catheter Cardiovasc Interv ; 95(5): 971-977, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-31231978

RESUMO

We report a case of a celiac trunk stenting using a steerable guiding catheter, to fix a residual endoleak following fenestrated endovascular repair (FEVAR) of a thoraco-abdominal aortic aneurysm (TAAA). A systematic search of the literature about the use of steerable catheters was also performed on Pubmed according to the PRISMA Guidelines, including all papers in which the device was used for in vivo endovascular procedures. In our case report, the patient had undergone a failed attempt of cannulation due to the presence of a severely angulated and stenosed ostium of the vessel. A steerable catheter was then used to fix the residual endoleak. The search of the Literature retrieved 544 papers. Of them, 13 met the inclusion criteria and were therefore assessed. The use of steerable sheaths and catheters was reported as effective and safe for the cannulation of 157 target vessels in 131 endovascular procedures, with a success rate of 95.5% and no complications. The use of a steerable guiding catheter in our experience was safe and effective for the selective cannulation of a severely stenosed and angulated celiac trunk, to correct a residual endoleak after FEVAR for TAAA. Steerable catheters could be useful tools for the selective cannulation of target vessels with a challenging ostium.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Cateterismo Periférico/instrumentação , Endoleak/terapia , Procedimentos Endovasculares/instrumentação , Dispositivos de Acesso Vascular , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/fisiopatologia , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/fisiopatologia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Cateterismo Periférico/efeitos adversos , Artéria Celíaca/diagnóstico por imagem , Artéria Celíaca/fisiopatologia , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/fisiopatologia , Procedimentos Endovasculares/efeitos adversos , Humanos , Masculino , Obstrução da Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/fisiopatologia , Stents , Resultado do Tratamento
15.
J Endovasc Ther ; 27(2): 304-315, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31989855

RESUMO

Purpose: To further investigate the safety and performance of the Passeo-18 Lux drug-coated balloon (DCB) for the treatment of atherosclerotic infrainguinal disease under real-world conditions. Materials and Methods: BIOLUX P-III is an international, prospective, observational registry (ClinicalTrials.gov identifier NCT02276313) conducted at 41 centers in Europe, Asia, and Australia with follow-up visits at 6, 12, and 24 months. Of 700 patients (mean age 70.0±10.2 years; 439 men) with 863 lesions in the all-comers cohort, 330 (47.1%) patients had diabetes and 234 (37.7%) had chronic limb-threatening ischemia. The majority (79.3%) of lesions were in the femoropopliteal segment; of all lesions, 645 (74.9%) were calcified and 99 (11.5%) had in-stent restenosis (ISR). The mean lesion length was 84.7±73.3 mm. The primary clinical endpoint was major adverse events (MAEs) within 6 months, a composite of device- and procedure-related mortality through 30 days, major target limb amputation, and clinically-driven target lesion revascularization (TLR). The primary performance endpoint was clinically-driven TLR within 12 months. Results: At 6 and 12 months, freedom from MAEs was 94.0% and 89.5% in the all-comers cohort: 95.0% and 91.2% in the femoropopliteal group and 95.3% and 88.0% in the ISR subgroup, respectively. Freedom from clinically-driven TLR at 12 months was 93.1% in the all-comers cohort, 93.9% in the femoropopliteal lesions, and 89.4% for ISR lesions. All-cause mortality was 6.1% in the all-comers cohort: 5.9% in both the femoropopliteal and ISR subgroups. There were no device- or procedure-related deaths at up to 12 months. The Rutherford category improved in >80% of all subgroups at 12 months. Conclusion: In a real-world patient population, the safety and performance of the Passeo-18 Lux DCB for the treatment of atherosclerotic infrainguinal lesions are maintained, with good performance outcomes and low complication rates at 12 months.


Assuntos
Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Artéria Femoral , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Artéria Poplítea , Dispositivos de Acesso Vascular , Idoso , Amputação Cirúrgica , Angioplastia com Balão/efeitos adversos , Ásia , Austrália , Fármacos Cardiovasculares/efeitos adversos , Desenho de Equipamento , Europa (Continente) , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Salvamento de Membro , Masculino , Paclitaxel/efeitos adversos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Intervalo Livre de Progressão , Estudos Prospectivos , Sistema de Registros , Fatores de Tempo , Grau de Desobstrução Vascular
16.
Eur J Vasc Endovasc Surg ; 59(5): 808-816, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31889656

RESUMO

OBJECTIVE: The aim was to investigate whether the "bovine" aortic arch (i.e. arch variant with a common origin of the innominate and left carotid artery (CILCA)) is associated with a consistent geometric configuration of proximal landing zones for thoracic endovascular aortic repair (TEVAR). METHODS: Anonymised thoracic computed tomography (CT) scans of healthy aortas were reviewed to retrieve 100 cases of CILCA. Suitable cases were stratified according to type 1 and 2 CILCA, and also based on type of arch (I, II, and III). Further processing allowed calculation of angulation and tortuosity of the proximal landing zones. Centre lumen line lengths of each proximal landing zone were measured in a view perpendicular to the centre line. All geometric features were compared with those measured in healthy patients with a standard arch configuration (n = 60). Two senior authors independently evaluated the CT scans, and intra- and interobserver repeatability were assessed. RESULTS: The 100 selected patients (63% male) were 71.4 ± 7.7 years old. Type 1 CILCA (62/100) was more prevalent than type 2 CILCA (38/100), and the two groups were comparable in age (p = .11). Zone 3 presented a severe angulation (i.e. > 60°), which was greater than in Zone 2 (p < .001), and a consistently greater tortuosity than Zone 2 (p = .003). This pattern did not differ between type 1 and type 2 CILCA. A greater tortuosity was also observed in Zone 0, which was related to increased elongation of the ascending aorta (i.e. Zone 0), than the standard configuration. The CILCA had an overall greater elongation, and Zone 2 also was specifically longer. When stratifying by type of arch, reversely from Type III to Type I, the CILCA presented a gradual flattening of its transverse tract, which entailed a consistent progressive elongation (p = .03) and kinking of the ascending aorta, with a significant increase of Zone 0 angulation to even a severe degree (p = .001). Also, from Type III to Type I, Zone 2 presented a progressively shorter length (p = .004), which was associated with increased tortuosity (p < .05). Mean intra- and interobserver differences for angulation measurements were 1.4° ± 6.8° (p = .17) and 2.0° ± 10.1° (p = .19), respectively. CONCLUSION: CILCA presents a consistent and peculiar geometric pattern compared with standard arch configuration, which provides relevant information for TEVAR planning, and may have prognostic implications.


Assuntos
Variação Anatômica , Aorta Torácica/anatomia & histologia , Aorta Torácica/diagnóstico por imagem , Tronco Braquiocefálico/anatomia & histologia , Tronco Braquiocefálico/diagnóstico por imagem , Artérias Carótidas/anatomia & histologia , Artérias Carótidas/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
17.
Ann Vasc Surg ; 66: 462-469, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31863950

RESUMO

BACKGROUND: The aim of the study was to report early and late outcomes of surgical and endovascular management of subclavian artery atherosclerotic disease (SAAD). METHODS: Data about consecutive patients treated for subclavian artery atherosclerotic occlusive disease between 2001 and 2018 either by open surgical repair (OSR) or by endovascular repair (ER) were retrospectively collected and analyzed. Primary outcomes included 30-day death, as well as cardiac and neurologic events, reported separately for occlusion and stenosis. Secondary outcomes included primary patency in the long term, reported separately for occlusive and stenotic lesions. The Kaplan-Meier analysis with the logrank test was used to estimate long-term primary patency. Chi-squared and t-tests were used as appropriate to compare the outcomes of the 2 groups. A P value < 0.05 was considered statistically significant. RESULTS: Sixty-eight patients were treated using ER (49 patients) and OSR (19). Technical success rate was 100% in both groups. During in-hospital stay, 1 brachial hematoma and 2 acute upper limb ischemia occurred in the ER group and in the OSR group, respectively. At 30 days, no deaths or neurological/cardiac events were recorded in both ER and OSR groups. Symptoms resolution and upper limb salvage were 100% in both groups. In the ER group, primary patency was 100% at 7 years in patients who had been treated for stenotic lesions and 62.5 ± 21.3% in patients who had been treated for occlusive lesions (P = 0.0035). In the OSR group, primary patency was 100% at 7 years in patients treated for stenotic lesions and 25 ± 21.6% in patients who had been treated for occlusive lesions (P < 0.0001). Overall, long-term primary patency in the OSR group was 76.9 ± 11.7% at 7 years, being lower than that reported after ER (93.4 ± 4.5%, P = 0.02). CONCLUSIONS: Both ER and OSR proved to be safe, effective, and durable in the treatment of SAAD. In particular, the primary patency rates at long term for both ER and OSR showed better outcomes for stenotic lesions.


Assuntos
Arteriopatias Oclusivas/terapia , Implante de Prótese Vascular , Procedimentos Endovasculares , Veia Safena/transplante , Artéria Subclávia/cirurgia , Síndrome do Roubo Subclávio/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/fisiopatologia , Síndrome do Roubo Subclávio/diagnóstico por imagem , Síndrome do Roubo Subclávio/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
18.
Ann Vasc Surg ; 69: 413-417, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32479874

RESUMO

BACKGROUND: To assess the endograft displacement forces (DF), which quantify the forces exerted by the pulsatile blood flow on the vessel wall and transmitted on the terminal fixation site of the endograft after its deployment in proximal landing zones (PLZs) of the bovine aortic arch variant. METHODS: Thirty healthy aortic computed tomographic angiographies of subjects with bovine arch configuration (10 per type of arch, I-III) were selected for the purpose of the study. A 3-dimensional model of the aortic arch lumen was reconstructed. Computational fluid dynamics modeling was then used to compute DF magnitude and orientation (i.e., x, y, and z axes) in PLZs of each case. DF values were normalized to the corresponding aortic wall area to estimate equivalent surface traction (EST). RESULTS: DF were highest in zone 0, consistently with the greater surface area. DF in zone 3 were much greater than in zone 2 because of a 3-fold greater upward component (z axis) (P < 0.001), being therefore mainly oriented orthogonally to the aortic blood flow and to the vessel longitudinal axis in that zone. EST progressively increased from zone 0 toward more distal PLZs, with EST in zone 3 being much greater than that in zone 2 (P < 0.001). The same pattern was observed after stratification by type of arch. CONCLUSIONS: The bovine arch is associated with a consistent fluid dynamic pattern, which identifies in zone 3 an unfavorable biomechanical environment for endograft deployment.


Assuntos
Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Simulação por Computador , Procedimentos Endovasculares/instrumentação , Hemodinâmica , Modelos Cardiovasculares , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Aortografia , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Hidrodinâmica , Masculino , Fluxo Pulsátil , Estudos Retrospectivos , Estresse Mecânico
19.
Ann Vasc Surg ; 68: 505-509, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32339684

RESUMO

BACKGROUND: Type III arch configuration is frequently reported as a stroke risk factor for carotid angioplasty and stenting (CAS). We reviewed contemporary guidelines on management of carotid artery stenosis to assess the clinical relevance attributed to this anatomic feature in current clinical practice. METHODS: The study was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. The PubMed, EMBASE, and Web of Science databases were searched to identify all guidelines on extracranial carotid disease published between January 2008 and March 2020. A total of 435 articles were screened. For multiple guidelines from the same writing group, only the most recent updated version was considered. Eighteen documents were identified for qualitative analysis. RESULTS: Four guidelines specifically reported type III arch as a predictive factor of periprocedural complications after CAS. Two of them also provided a low level of evidence of their recommendation. None of the documents indicated the exact criteria for aortic arch classification. Three different methods to describe type III arch configuration were identified. CONCLUSIONS: Type III arch configuration is inconsistently included among stroke risk factors for CAS in contemporary guidelines, and variably defined. Further studies on the level of concordance between the 3 existing definition criteria are warranted.


Assuntos
Angioplastia/instrumentação , Aorta Torácica/anormalidades , Estenose das Carótidas/terapia , Stents , Malformações Vasculares/complicações , Angioplastia/efeitos adversos , Aorta Torácica/diagnóstico por imagem , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Humanos , Guias de Prática Clínica como Assunto , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Malformações Vasculares/diagnóstico por imagem
20.
Ann Vasc Surg ; 65: 282.e5-282.e8, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31863958

RESUMO

Iatrogenic femoral arteriovenous fistulas (AVFs) and deep venous thrombosis (DVT) can complicate femoral artery catheterization procedures. However, the co-occurrence of both is rare. We report the unique case of AVF with DVT, which occurred in the right femoral vessels of a 59-year-old man with a right iliac fossa kidney transplant, after percutaneous puncture for cardiac catheterization. Duplex ultrasound examination and computed tomography venography scan confirmed the diagnosis. Both the AVF and the DVT were managed surgically.


Assuntos
Fístula Arteriovenosa/etiologia , Ablação por Cateter/efeitos adversos , Cateterismo Periférico/efeitos adversos , Artéria Femoral/lesões , Veia Femoral/lesões , Doença Iatrogênica , Transplante de Rim , Lesões do Sistema Vascular/etiologia , Trombose Venosa/etiologia , Anticoagulantes/uso terapêutico , Fístula Arteriovenosa/diagnóstico por imagem , Fístula Arteriovenosa/cirurgia , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Veia Femoral/diagnóstico por imagem , Veia Femoral/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Meias de Compressão , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/cirurgia , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA