Ann Vasc Surg ; 99: 305-311, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37858669

RESUMO

BACKGROUND: Popliteal artery injury (PAI) is a challenging trauma that requires prompt and accurate treatment since the probability of lower-limb amputation increases with the ischemic time. Intravascular shunting and cross-limb vascular shunting (CLS) are used as temporary vascular shunting (TVS) methods to shorten the ischemic time for limb vascular injury. CLS involves sending blood from an artery in a healthy body part to a peripheral vessel in an injured part to immediately resume blood flow to the injured limb. For closed injuries including PAI, CLS may be performed without exploring and identifying the arterial stumps and it enables early reperfusion to the ischemic limb. We report the case series of traumatic PAI treated using CLS and verify the usefulness of CLS. METHODS: All patients with traumatic PAI treated with CLS at our institution between August 2013 and December 2021 were included. Demographic and clinical patient characteristics were extracted from the medical records. Comorbid injuries, severity of acute limb ischemia based on the Rutherford grading scale, time from injury to reperfusion by CLS, time from injury to completion of artery, and the use of fasciotomy were investigated. As outcomes, we investigated the presence or absence of lower extremity amputation during the course of treatment. RESULTS: We used CLS as treatment for 5 cases with traumatic PAI. Based on the Rutherford grading scale for acute limb ischemia, there were one limb with grade 2B and 4 with grade 3. Amputation of the lower extremities was avoided except for 1 extremity in which arterial reconstruction was not achieved due to unexplained cardiac arrest during surgery. CONCLUSIONS: CLS enables early reperfusion of the injured limb and is effective as a TVS method for traumatic PAI with severe ischemia or soft tissue damage.


Assuntos
Artéria Poplítea , Lesões do Sistema Vascular , Humanos , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/cirurgia , Artéria Poplítea/lesões , Salvamento de Membro/efeitos adversos , Resultado do Tratamento , Extremidade Inferior/cirurgia , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/cirurgia , Isquemia/diagnóstico por imagem , Isquemia/etiologia , Isquemia/cirurgia , Estudos Retrospectivos
2.
J Orthop Sci ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38604874

RESUMO

BACKGROUND: Although the concept of the "fix and flap" approach, in which definitive fracture fixation and flap coverage are completed in a single procedure at the earliest opportunity may seem ideal for the treatment of Gustilo type IIIB open fractures, the individual circumstances of patients, such as polytrauma or multiple fracture cases may not allow for the immediate fracture fixation and flap coverage ("fix and flap" approach). In our hospital, patients with Gustilo type IIIB open fractures are treated with definitive internal fixation of the fracture followed by staged flap coverage ("fix followed by flap" protocol) when the "fix and flap" approach was not feasible due to the patient's condition or difficulty in coordinating surgery schedules. The "fix followed by flap" protocol provides benefits in terms of flexibility in adjusting the surgical timetable, simplifying the planning of flap coverage following fracture fixation, and minimizing individual surgical invasion. METHODS: We reviewed 10 cases of severe open fractures treated with the "fix followed by flap" protocol and evaluated their outcomes. All surgical procedures, including wound debridement, fracture fixation, and flap coverage, were performed by orthoplastic surgeons specializing in both fracture surgery and microsurgery including soft tissue reconstruction. RESULTS: All free flaps survived, and no partial necrosis was observed. None of the patients developed postoperative deep infection up to the last follow-up. Fracture union was achieved in all patients with or without autologous bone grafts. The median time for union was 9.4 months (range, 4-12 months). CONCLUSIONS: This study presents favorable outcomes of treatment for Gustilo type IIIB open fractures with fracture fixation followed by staged flap coverage ("fix followed by flap" protocol). Despite a delay in flap coverage, the consistency of treatment provided by orthoplastic surgeons may have contributed to the favorable outcomes in this study.

3.
Int Orthop ; 47(6): 1565-1573, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36932220

RESUMO

PURPOSE: The present study investigated the outcomes of bone loss associated with acute open tibial fractures classified as Gustilo-Anderson classification grade III B (GIIIB) using a bone length preservation strategy. METHODS: Among acute GIIIB open tibial fractures, 29 limbs of 29 patients requiring bone loss treatment were included. The reconstruction methods for bone loss were selected among the Masquelet technique (MT), bone transport (BT), acute shortening followed by gradual lengthening (ASGL), and free vascularized fibula graft (FVFG). Primary outcome measures were the rate of bone union and time to bone union. RESULTS: The median radiographic apparent bone gap (RABG) was 46.75 mm. Bone loss was treated with ASGL only in two patients in whom it was not possible to cover large soft tissue defects by a single free latissimus dorsi (LD) myocutaneous flap (with the serratus anterior (SA) muscle). The other 27 patients underwent soft tissue reconstruction and bone loss treatment with the preservation of bone length, including the MT for 23, BT for six, and FVFG for one. The bone union rate was 75.9%, and the median time to bone union was six months. Salvage surgeries were performed on all seven patients with nonunion; all of whom eventually achieved bony union. CONCLUSION: Bone loss associated with acute GIIIB open tibial fractures were treated with "bone length preservation" if the size of the soft tissue defect was less than the size that was covered by a single LD myocutaneous flap (with the SA muscle).


Assuntos
Doenças Ósseas Metabólicas , Fraturas Expostas , Procedimentos de Cirurgia Plástica , Fraturas da Tíbia , Humanos , Estudos Retrospectivos , Retalhos Cirúrgicos , Fraturas da Tíbia/complicações , Fraturas da Tíbia/cirurgia , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Fraturas Expostas/complicações , Fraturas Expostas/cirurgia , Doenças Ósseas Metabólicas/cirurgia , Resultado do Tratamento
4.
Eur J Orthop Surg Traumatol ; 33(4): 1101-1107, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35403907

RESUMO

PURPOSE: Postoperative over-telescoping (OT) with lag screws is often observed in reverse oblique intertrochanteric fractures. This study aimed to clarify the risk factors of OT in patients with reverse oblique intertrochanteric fractures. METHODS: Electronic medical records of patients diagnosed with reverse oblique intertrochanteric fractures using plain radiography who underwent operative fixation with an intramedullary nail between August 2013 and December 2019 were reviewed. Patients were classified into two groups according to the Futamura classification: lateral wall pattern (LW) and reverse oblique pattern (RO). The incidence of OT in the LW and RO groups was compared. Also, we compared the incidence of OT for each reduction type in the LW group. RESULTS: Twenty patients had LW, and nine had RO. OT was observed in eight fractures (42.1%) in the LW group but not in the RO group. The incidence of OT was significantly higher in the LW group than in the RO group (P = 0.0261). Among the 19 fractures with LW, OT was observed in 7 of 10 and 1 of 9 fractures with postoperative reduction in the intramedullary and extramedullary or anatomical types, respectively. In the LW group, the incidence of OT was significantly higher in fractures with postoperative reduction in the intramedullary type than in those of the extramedullary or anatomical type (P = 0.0198). CONCLUSION: Our study showed that the incidence of OT was significantly higher in LW than in RO and that postoperative reduction in the intramedullary type in LW was a risk factor for OT.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Humanos , Pinos Ortopédicos , Fixação Intramedular de Fraturas/efeitos adversos , Fraturas do Quadril/cirurgia , Parafusos Ósseos , Fatores de Risco , Resultado do Tratamento
5.
J Artif Organs ; 24(2): 120-125, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33136218

RESUMO

A suitable index is needed for hemolysis tests that use low-flow pumps, such as pediatric blood pumps or blood purification pumps. To create such an index, the present study investigates the change of plasma-free hemoglobin in the pump circuit with time and the change of the hemolysis rate with flow rate and impeller rotational speed. The results show that the hemolysis rate or the increase rate of the total free hemoglobin are suitable measures for hemolysis evaluation for low-flow pumps.


Assuntos
Coração Auxiliar , Hemólise , Algoritmos , Animais , Bovinos , Hemodinâmica , Hemoglobinas
6.
J Artif Organs ; 24(2): 126-134, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33113050

RESUMO

This work investigates the plasma skimming effect in a spiral groove bearing within a hydrodynamically levitated centrifugal blood pump when working with human blood having a hematocrit value from 0 to 40%. The present study assessed the evaluation based on a method that clarified the limitations associated with such assessments. Human blood was circulated in a closed-loop circuit via a pump operating at 4000 rpm at a flow rate of 5 L/min. Red blood cells flowing through a ridge area of the bearing were directly observed using a high-speed microscope. The hematocrit value in the ridge area was calculated using the mean corpuscular volume, the bearing gap, the cross-sectional area of a red blood cell, and the occupancy of red blood cells. The latter value was obtained from photographic images by dividing the number of pixels showing red blood cells in the evaluation area by the total number of pixels in this area. The plasma skimming efficiency was calculated as the extent to which the hematocrit of the working blood was reduced in the ridge area. For the hematocrit in the circuit from 0 to 40%, the plasma skimming efficiency was approximately 90%, meaning that the hematocrit in the ridge area became 10% as compared to that in the circuit. For a hematocrit of 20% and over, red blood cells almost completely occupied the ridge. Thus, a valid assessment of plasma skimming was only possible when the hematocrit was less than 20%.


Assuntos
Eritrócitos , Coração Auxiliar , Circulação Assistida , Centrifugação , Hematócrito , Hemólise , Humanos , Hidrodinâmica , Desenho de Prótese
7.
J Artif Organs ; 24(2): 157-163, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33428006

RESUMO

We have developed a hydrodynamically levitated centrifugal blood pump. In the blood pump having hydrodynamic bearings, the narrow bearing gap has a potential for high hemolysis. The purpose of the this study is to improve hemolysis performance in a hydrodynamically levitated centrifugal blood pump by optimizing a shroud size. The impeller was levitated passively at the position where the thrust forces acting on the impeller were balanced. We focused on a size of a bottom shroud with a hydrodynamic bearing that could change the bottom hydrodynamic force to balance the thrust force at the wide bearing gap for reducing hemolysis. Five test models with various shroud size were compared: 989 mm2 (HH-10.5), 962 mm2 (HH-12), 932 mm2 (HH-13.5), 874 mm2 (HH-16), and 821 mm2 (HH-18). A numerical analysis was first performed to estimate the bearing gaps in the test model. The bearing gaps were then measured to validate the numerical analysis. Finally, an in vitro hemolysis test was performed. The numerical analysis revealed that the HH-13.5 model had the widest bearing gap of 129 µm. In the measurement test, the estimation error for the bearing gap was less than 10%. In the hemolysis test, the HH-13.5 model achieved the lowest hemolysis level among the five models. The present study demonstrated that the numerical analysis was found to be effective for determining the optimal should size, and the HH-13.5 model had the optimal shroud size in the developed hydrodynamically levitated centrifugal blood pump to reduce hemolysis.


Assuntos
Coração Auxiliar , Hemólise , Centrifugação , Desenho de Equipamento , Humanos , Hidrodinâmica , Desenho de Prótese
9.
Bioorg Med Chem Lett ; 28(14): 2408-2412, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29934246

RESUMO

We describe a medicinal chemistry approach to the discovery of a novel EP1 antagonist exhibiting high potency and good pharmacokinetics. Our starting point is 1, an EP1 receptor antagonist that exhibits pharmacological efficacy in cystometry models following intravenous administration. Despite its good potency in vitro, the high lipophilicity of 1 is a concern in long-term in vivo studies. Further medicinal chemistry efforts identified 4 as an improved lead compound with good in vitro ADME profile applicable to long term in vivo studies. A rat fracture study was conducted with 4 for 4 weeks to validate its utility in bone fracture healing. The results suggest that this EP1 receptor antagonist stimulates callus formation and thus 4 has potential for enhancing fracture healing.


Assuntos
Descoberta de Drogas , Consolidação da Fratura/efeitos dos fármacos , Fraturas Ósseas/tratamento farmacológico , Receptores de Prostaglandina E Subtipo EP1/antagonistas & inibidores , Tiazóis/farmacologia , Animais , Modelos Animais de Doenças , Cães , Relação Dose-Resposta a Droga , Fraturas Ósseas/metabolismo , Células Madin Darby de Rim Canino/efeitos dos fármacos , Células Madin Darby de Rim Canino/metabolismo , Células Madin Darby de Rim Canino/patologia , Camundongos , Camundongos Knockout , Estrutura Molecular , Receptores de Prostaglandina E Subtipo EP1/deficiência , Receptores de Prostaglandina E Subtipo EP1/metabolismo , Relação Estrutura-Atividade , Tiazóis/química
11.
J Artif Organs ; 20(3): 187-193, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28620709

RESUMO

This review was created based on a translation of the Japanese review written in the Japanese Journal of Artificial Organs in 2015 (Vol.44, No. 3, pp.130-135), with some modifications regarding several references published in 2015 or later.


Assuntos
Cardiologia , Coração Artificial/tendências , Publicações Periódicas como Assunto , Sistema de Registros , Humanos , Japão
12.
J Artif Organs ; 20(1): 26-33, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27815718

RESUMO

A long-term durability test was conducted on a newly developed axial-flow ventricular assist device (VAD) with hydrodynamic bearings. The mock circulatory loop consisted of a diaphragm pump with a mechanical heart valve, a reservoir, a compliance tank, a resistance valve, and flow paths made of polymer or titanium. The VAD was installed behind the diaphragm pump. The blood analog fluid was a saline solution with added glycerin at a temperature of 37 °C. A pulsatile flow was introduced into the VAD over a range of flow rates to realize a positive flow rate and a positive pressure head at a given impeller rotational speed, yielding a flow rate of 5 L/min and a pressure of 100 mmHg. Pulsatile flow conditions were achieved with the diastolic and systolic flow rates of ~0 and 9.5 L/min, respectively, and an average flow rate of ~5 L/min at a pulse rate of 72 bpm. The VAD operation was judged by not only the rotational speed of the impeller, but also the diastolic, systolic, and average flow rates and the average pressure head of the VAD. The conditions of the mock circulatory loop, including the pulse rate of the diaphragm pump, the fluid temperature, and the fluid viscosity were maintained. Eight VADs were tested with testing periods of 2 years, during which they were continuously in operation. The VAD performance factors, including the power consumption and the vibration characteristics, were kept almost constant. The long-term durability of the developed VAD was successfully demonstrated.


Assuntos
Coração Auxiliar , Fluxo Pulsátil , Pressão Sanguínea , Humanos , Hidrodinâmica , Teste de Materiais , Pressão
13.
Artif Organs ; 40(6): E89-E101, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27097844

RESUMO

The effect of the flow path geometry of the impeller on the lift-off and tilt of the rotational axis of the impeller against the hydrodynamic force was investigated in a centrifugal blood pump with an impeller supported by a single-contact pivot bearing. Four types of impeller were compared: the FR model with the flow path having both front and rear cutouts on the tip, the F model with the flow path having only a front cutout, the R model with only a rear cutout, and the N model with a straight flow path. First, the axial thrust and the movement about the pivot point, which was loaded on the surface of the impeller, were calculated using computational fluid dynamics (CFD) analysis. Next, the lift-off point and the tilt of the rotational axis of the impeller were measured experimentally. The CFD analysis showed that the axial thrust increased gently in the FR and R models as the flow rate increased, whereas it increased drastically in the F and N models. This difference in axial thrust was likely from the higher pressure caused by the smaller circumferential velocity in the gap between the top surface of the impeller and the casing in the FR and R models than in the F and N models, which was caused by the rear cutout. These results corresponded with the experimental results showing that the impellers lifted off in the F and N models as the flow rate increased, whereas it did not in the FR and R models. Conversely, the movement about the pivot point increased in the direction opposite the side with the pump outlet as the flow rate increased. However, the tilt of the rotational axis of the impeller, which oriented away from the pump outlet, was less than 0.8° in any model under any conditions, and was considered to negligibly affect the rotational attitude of the impeller. These results confirm that a rear cutout prevents lift-off of the impeller caused by a decrease in the axial thrust.


Assuntos
Circulação Assistida/instrumentação , Hidrodinâmica , Engenharia Biomédica , Simulação por Computador , Desenho de Equipamento , Humanos
14.
Artif Organs ; 40(9): 856-66, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27645396

RESUMO

Plasma skimming is a phenomenon in which discharge hematocrit is lower than feed hematocrit in microvessels. Plasma skimming has been investigated at a bearing gap in a spiral groove bearing (SGB), as this has the potential to prevent hemolysis in the SGB of a blood pump. However, it is not clear whether plasma skimming occurs in a blood pump with the SGB, because the hematocrit has not been obtained. The purpose of this study is to verify plasma skimming in an SGB of a centrifugal blood pump by developing a hematocrit measurement method in an SGB. Erythrocyte observation using a high-speed microscope and a bearing gap measurement using a laser confocal displacement meter was performed five times. In these tests, bovine blood as a working fluid was diluted with autologous plasma to adjust the hematocrit to 1.0%. A resistor was adjusted to achieve a pressure head of 100 mm Hg and a flow rate of 5.0 L/min at a rotational speed of 2800 rpm. Hematocrit on the ridge region in the SGB was measured using an image analysis based on motion image of erythrocytes, mean corpuscular volume, the measured bearing gap, and a cross-sectional area of erythrocyte. Mean hematocrit on the ridge region in the SGB was linearly reduced from 0.97 to 0.07% with the decreasing mean bearing gap from 38 to 21 µm when the rotational speed was changed from 2250 to 3000 rpm. A maximum plasma skimming efficiency of 93% was obtained with a gap of 21 µm. In conclusion, we succeeded in measuring the hematocrit on the ridge region in the SGB of the blood pump. Hematocrit decreased on the ridge region in the SGB and plasma skimming occurred with a bearing gap of less than 30 µm in the hydrodynamically levitated centrifugal blood pump.


Assuntos
Circulação Assistida/instrumentação , Eritrócitos/citologia , Hematócrito/métodos , Algoritmos , Animais , Bovinos , Centrifugação/instrumentação , Desenho de Equipamento , Índices de Eritrócitos , Hidrodinâmica , Microvasos/fisiologia
15.
J Artif Organs ; 19(3): 241-8, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27010641

RESUMO

The aggregability of red blood cell (RBCs) is associated with the contribution of plasma proteins, such as fibrinogen and lipoproteids, to blood-clotting. Hence, we hypothesized that RBC aggregability reflects the blood-clotting reaction. A noninvasive optical monitoring method to measure RBC aggregability for the assessment of blood-clotting stage during mechanical circulatory support was developed. An in vitro thrombogenic test was conducted with a rotary blood pump using heparinized fresh porcine blood. Near-infrared laser light at a wavelength of 785 nm was guided by an optical fiber. The fibers for detecting incident, forward-, and backward-scattered light were fixed on the circuit tubing with an inner diameter of 1/4 inch. Because there is substantial RBC aggregation at low shear flow rates, a pulsatile flow was generated by controlling the pump rotational speed. The flow rate was changed from 0 to 8.5 L/min at a period of 40 s. The intensities of forward- and backward-scattered light changed dramatically when the flow stopped. The aggregability was evaluated by the increase ratio of the transmitted light intensity from the flow stopping in the low-flow condition. The experiment started when the anticoagulation was stopped by the addition of protamine into the circulating blood. Reduction in RBC aggregability was associated with a decrease in the amount of fibrinogen and the number of platelets. Continuous, noninvasive monitoring of thrombosis risk is possible using optical measurements combining pulsatile flow control of a rotary blood pump. RBC aggregometry is a potential label-free method for evaluating blood-clotting risk.


Assuntos
Agregação Eritrocítica/fisiologia , Eritrócitos/citologia , Circulação Extracorpórea , Animais , Suínos
16.
J Artif Organs ; 19(4): 322-329, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27370698

RESUMO

An impeller the same geometry as the impeller of a commercial monopivot cardiopulmonary bypass pump was manufactured using 3D printing. The 3D-printed impeller was integrated into the pump casing of the commercially available pump to form a 3D-printed pump model. The surface roughness of the impeller, the hydraulic performance, the axial displacement of the rotating impeller, and the hemolytic properties of the 3D-printed model were measured and compared with those of the commercially available model. Although the surface roughness of the 3D-printed model was significantly larger than that of the commercially available model, the hydraulic performance of the two models almost coincided. The hemolysis level of the 3D-printed model roughly coincided with that of the commercially available model under low-pressure head conditions, but increased greatly under high-pressure head conditions, as a result of the narrow gap between the rotating impeller and the pump casing. The gap became narrow under high-pressure head conditions, because the axial thrust applied to the impeller increased with increasing impeller rotational speed. Moreover, the axial displacement of the rotating impeller was twice that of the commercially available model, confirming that the elastic deformation of the 3D-printed impeller was larger than that of the commercially available impeller. These results suggest that trial models manufactured by 3D printing can reproduce the hydraulic performance of the commercial product. However, both the surface roughness and the deformation of the trial models must be considered to precisely evaluate the hemolytic properties of the model.


Assuntos
Coração Auxiliar , Impressão Tridimensional , Ponte Cardiopulmonar , Desenho de Equipamento , Hemólise , Hemorreologia , Humanos , Pressão
17.
Kekkaku ; 91(7): 569-577, 2016 Jul.
Artigo em Japonês | MEDLINE | ID: mdl-30646451

RESUMO

[Aim] To determine genotypes of Mycobacterium tuberculosis strains in Fukuoka Prefecture, Japan. [Methods] A total of 296 isolates from 296 tuberculosis patients is tested using 24-locus variable-number tandem- repeat (VNTR) typing. We also determined whether these isolates and a further 10 were Beijing lineage. [Results] The 296 isolates were classified into 264 VNTR types, and re-classified into 25 clusters when each cluster was defined as isolates being identical to VNTR types in 24 regions, or in 23 regions with the exception of one hypervariable region. Two clusters were shown to be identical to that of the Kansai regional epidemic. Regarding regional diversity, hypervariable regions showed relatively higher variation of isolate types. The Beijing lineage accounted for 78.1% of all isolates, which was similar to the value obtained from Kobe (78.5% in 2009) in the Kansai region. [Discussion] Six isolates from Fukuoka Prefecture over- lapped with those from Kansai region with respect to domi- nant VNTR type, while clusters from Fukuoka Prefectural isolates were unique, which may be a feature of Fukuoka prefectural isolates. [Conclusion] These data are likely to be useful for public health measures in the area.


Assuntos
DNA Bacteriano/genética , Mycobacterium tuberculosis/genética , Tuberculose , Genótipo , Humanos , Japão/epidemiologia , Repetições Minissatélites , Mycobacterium tuberculosis/isolamento & purificação , Tuberculose/epidemiologia
18.
Artif Organs ; 39(8): 714-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26234451

RESUMO

Understanding the thrombus formation in cardiovascular devices such as rotary blood pumps is the most important issue in developing more hemocompatible devices. The objective of this study was to develop a hyperspectral imaging (HSI) method to visualize the thrombus growth process within a rotary blood pump and investigate the optical properties of the thrombus. An in vitro thrombogenic test was conducted using fresh porcine blood and a specially designed hydrodynamically levitated centrifugal blood pump with a transparent bottom. The pump rotating at 3000 rpm circulated the blood at 1.0 L/min. The bottom surface of the pump was illuminated with white light pulsed at the same frequency as the pump rotation, and the backward-scattered light was imaged using the HSI system. Using stroboscopic HSI and an image construction algorithm, dynamic spectral imaging at wavelengths ranging from 608 to 752 nm within the rotating pump was achieved. After completing the experiment, we collected the red thrombus formed in the pump impeller and quantified the thrombus hemoglobin concentration (Hbthrombus ). The spectrum changed around the center of the impeller, and the area of change expanded toward the impeller flow path. The shape corresponded approximately to the shape of the thrombus. The spectrum change indicated that the light scattering derived from red blood cells decreased. The Hbthrombus was 4.7 ± 1.3 g/dL versus a total hemoglobin of 13 ± 0.87 g/dL. The study revealed that Hbthrombus was reduced by the surrounding blood flow.


Assuntos
Coração Auxiliar/efeitos adversos , Hemodinâmica , Espectroscopia de Luz Próxima ao Infravermelho , Estroboscopia , Trombose/etiologia , Algoritmos , Animais , Hidrodinâmica , Processamento de Imagem Assistida por Computador , Desenho de Prótese , Suínos , Trombose/sangue , Fatores de Tempo
19.
Artif Organs ; 39(8): 710-4, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26146791

RESUMO

The purpose of this study is to evaluate a spiral groove geometry for a thrust bearing to improve the hemolysis level in a hydrodynamically levitated centrifugal blood pump. We compared three geometric models: (i) the groove width is the same as the ridge width at any given polar coordinate (conventional model); (ii) the groove width contracts inward from 9.7 to 0.5 mm (contraction model); and (iii) the groove width expands inward from 0.5 to 4.2 mm (expansion model). To evaluate the hemolysis level, an impeller levitation performance test and in vitro hemolysis test were conducted using a mock circulation loop. In these tests, the driving conditions were set at a pressure head of 200 mm Hg and a flow rate of 4.0 L/min. As a result of the impeller levitation performance test, the bottom bearing gaps of the contraction and conventional models were 88 and 25 µm, respectively. The impeller of the expansion model touched the bottom housing. In the hemolysis test, the relative normalized index of hemolysis (NIH) ratios of the contraction model in comparison with BPX-80 and HPM-15 were 0.6 and 0.9, respectively. In contrast, the relative NIH ratios of the conventional model in comparison with BPX-80 and HPM-15 were 9.6 and 13.7, respectively. We confirmed that the contraction model achieved a large bearing gap and improved the hemolysis level in a hydrodynamically levitated centrifugal blood pump.


Assuntos
Coração Auxiliar/efeitos adversos , Hemodinâmica , Hemólise , Animais , Bovinos , Centrifugação , Modelos Anatômicos , Modelos Cardiovasculares , Desenho de Prótese , Estresse Mecânico , Fatores de Tempo
20.
J Artif Organs ; 18(3): 206-12, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25784463

RESUMO

The helical flow pump (HFP) was invented to be an ideal pump for developing the TAH and the helical flow TAH (HFTAH) using two HFPs has been developed. However, since the HFP is quite a new pump, hydrodynamic characteristics inside the pump are not clarified. To analyze hydrodynamic characteristics of the HFP, flow visualization study using the particle image velocimetry and computational fluid dynamics analysis were performed. The experimental and computational models were developed to simulate the left HFP of the HFTAH and distributions of flow velocity vectors, shear stress and pressure inside the pump were examined. In distribution of flow velocity vectors, the vortexes in the vane were observed, which indicated that the HFP has a novel and quite unique working principle in which centrifugal force rotates the fluid in the helical volutes and the fluid is transferred from the inlet to the outlet helical volutes according to the helical structure. In distribution of shear stress, the highest shear stress that was considered to be occurred by the shunt flow across the impeller was found around the entrance of the inlet helical volute. However, it was not so high to cause hemolysis. This shunt flow is thought to be improved by redesigning the inlet and outlet helical volutes. In distribution of pressure, negative pressure was found near the entrance of the inlet helical volute. However, it was not high. Negative pressure is thought to be reduced with an improvement in the design of the impeller or the vane shape.


Assuntos
Circulação Assistida/instrumentação , Coração Artificial , Simulação por Computador , Desenho de Equipamento , Hemorreologia , Humanos , Modelos Cardiovasculares , Reologia , Estresse Mecânico