Resultados 1 - 20 de 35
Filtrar
1.
Stroke ; 55(2): 474-483, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38018832

RESUMO

Stroke is a leading cause of paralysis, most frequently affecting the upper limbs and vocal folds. Despite recent advances in care, stroke recovery invariably reaches a plateau, after which there are permanent neurological impairments. Implantable brain-computer interface devices offer the potential to bypass permanent neurological lesions. They function by (1) recording neural activity, (2) decoding the neural signal occurring in response to volitional motor intentions, and (3) generating digital control signals that may be used to control external devices. While brain-computer interface technology has the potential to revolutionize neurological care, clinical translation has been limited. Endovascular arrays present a novel form of minimally invasive brain-computer interface devices that have been deployed in human subjects during early feasibility studies. This article provides an overview of endovascular brain-computer interface devices and critically evaluates the patient with stroke as an implant candidate. Future opportunities are mapped, along with the challenges arising when decoding neural activity following infarction. Limitations arise when considering intracerebral hemorrhage and motor cortex lesions; however, future directions are outlined that aim to address these challenges.


Assuntos
Interfaces Cérebro-Computador , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Paralisia/etiologia , Acidente Vascular Cerebral/complicações , Próteses e Implantes
2.
Artif Organs ; 46(3): 337-348, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34101849

RESUMO

Over the last few decades, biomedical implants have successfully delivered therapeutic electrical stimulation to reduce the frequency and severity of seizures in people with drug-resistant epilepsy. However, neurostimulation approaches require invasive surgery to implant stimulating electrodes, and surgical, medical, and hardware complications are not uncommon. An endovascular approach provides a potentially safer and less invasive surgical alternative. This article critically evaluates the feasibility of endovascular closed-loop neuromodulation for the treatment of epilepsy. By reviewing literature that reported the impact of direct electrical stimulation to reduce the frequency of epileptic seizures, we identified clinically validated extracranial, cortical, and deep cortical neural targets. We identified veins in close proximity to these targets and evaluated the potential of delivering an endovascular implant to these veins based on their diameter. We then compared the risks and benefits of existing technology to describe a benchmark of clinical safety and efficacy that would need to be achieved for endovascular neuromodulation to provide therapeutic benefit. For the majority of brain regions that have been clinically demonstrated to reduce seizure occurrence in response to delivered electrical stimulation, vessels of appropriate diameter for delivery of an endovascular electrode to these regions could be achieved. This includes delivery to the vagus nerve via the 13.2 ± 0.9 mm diameter internal jugular vein, the motor cortex via the 6.5 ± 1.7 mm diameter superior sagittal sinus, and the cerebellum via the 7.7 ± 1.4 mm diameter sigmoid sinus or 6.2 ± 1.4 mm diameter transverse sinus. Deep cerebral targets can also be accessed with an endovascular approach, with the 1.9 ± 0.5 mm diameter internal cerebral vein and 1.2-mm-diameter thalamostriate vein lying in close proximity to the anterior and centromedian nuclei of the thalamus, respectively. This work identified numerous veins that are in close proximity to conventional stimulation targets that are of a diameter large enough for delivery and deployment of an endovascular electrode array, supporting future work to assess clinical efficacy and chronic safety of an endovascular approach to deliver therapeutic neurostimulation.


Assuntos
Terapia por Estimulação Elétrica/métodos , Eletrodos Implantados , Procedimentos Endovasculares , Epilepsia/terapia , Encéfalo/irrigação sanguínea , Circulação Cerebrovascular , Resistência a Medicamentos , Humanos
3.
Neuroimage ; 164: 214-229, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-28286317

RESUMO

Recent developments in accelerated imaging methods allow faster acquisition of high spatial resolution images. This could improve the applications of functional magnetic resonance imaging at 7 Tesla (7T-fMRI), such as neurosurgical planning and Brain Computer Interfaces (BCIs). However, increasing the spatial and temporal resolution will both lead to signal-to-noise ratio (SNR) losses due to decreased net magnetization per voxel and T1-relaxation effect, respectively. This could potentially offset the SNR efficiency gains made with increasing temporal resolution. We investigated the effects of varying spatial and temporal resolution on fMRI sensitivity measures and their implications on fMRI-based BCI simulations. We compared temporal signal-to-noise ratio (tSNR), observed percent signal change (%∆S), volumes of significant activation, Z-scores and decoding performance of linear classifiers commonly used in BCIs across a range of spatial and temporal resolution images acquired during an ankle-tapping task. Our results revealed an average increase of 22% in %∆S (p=0.006) and 9% in decoding performance (p=0.015) with temporal resolution only at the highest spatial resolution of 1.5×1.5×1.5mm3, despite a 29% decrease in tSNR (p<0.001) and plateaued Z-scores. Further, the volume of significant activation was indifferent (p>0.05) across spatial resolution specifically at the highest temporal resolution of 500ms. These results demonstrate that the overall BOLD sensitivity can be increased significantly with temporal resolution, granted an adequately high spatial resolution with minimal physiological noise level. This shows the feasibility of diffuse motor-network imaging at high spatial and temporal resolution with robust BOLD sensitivity with 7T-fMRI. Importantly, we show that this sensitivity improvement could be extended to an fMRI application such as BCIs.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Rede Nervosa/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Adulto Jovem
4.
Hum Brain Mapp ; 39(6): 2635-2650, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29516636

RESUMO

Performing voluntary movements involves many regions of the brain, but it is unknown how they work together to plan and execute specific movements. We recorded high-resolution ultra-high-field blood-oxygen-level-dependent signal during a cued ankle-dorsiflexion task. The spatiotemporal dynamics and the patterns of task-relevant information flow across the dorsal motor network were investigated. We show that task-relevant information appears and decays earlier in the higher order areas of the dorsal motor network then in the primary motor cortex. Furthermore, the results show that task-relevant information is encoded in general initially, and then selective goals are subsequently encoded in specifics subregions across the network. Importantly, the patterns of recurrent information flow across the network vary across different subregions depending on the goal. Recurrent information flow was observed across all higher order areas of the dorsal motor network in the subregions encoding for the current goal. In contrast, only the top-down information flow from the supplementary motor cortex to the frontoparietal regions, with weakened recurrent information flow between the frontoparietal regions and bottom-up information flow from the frontoparietal regions to the supplementary cortex were observed in the subregions encoding for the opposing goal. We conclude that selective motor goal encoding and execution rely on goal-dependent differences in subregional recurrent information flow patterns across the long-range dorsal motor network areas that exhibit graded functional specialization.


Assuntos
Tomada de Decisões/fisiologia , Vias Eferentes/fisiologia , Objetivos , Atividade Motora/fisiologia , Desempenho Psicomotor/fisiologia , Adulto , Corpo Estriado/diagnóstico por imagem , Vias Eferentes/diagnóstico por imagem , Feminino , Lobo Frontal/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Oxigênio/sangue , Fatores de Tempo , Adulto Jovem
5.
MAGMA ; 31(5): 621-632, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29845434

RESUMO

OBJECTIVE: Ultra-high-field functional MRI (UHF-fMRI) allows for higher spatiotemporal resolution imaging. However, higher-resolution imaging entails coverage limitations. Processing partial-coverage images using standard pipelines leads to sub-optimal results. We aimed to develop a simple, semi-automated pipeline for processing partial-coverage UHF-fMRI data using widely used image processing algorithms. MATERIALS AND METHODS: We developed automated pipelines for optimized skull stripping and co-registration of partial-coverage UHF functional images, using built-in functions of the Centre for Functional Magnetic Resonance Imaging of the Brain's (FMRIB's) Software library (FSL) and advanced normalization tools. We incorporated the pipelines into the FSL's functional analysis pipeline and provide a semi-automated optimized partial-coverage functional analysis pipeline (OPFAP). RESULTS: Compared to the standard pipeline, the OPFAP yielded images with 15 and 30% greater volume of non-zero voxels after skull stripping the functional and anatomical images, respectively (all p = 0.0004), which reflected the conservation of cortical voxels lost when the standard pipeline was used. The OPFAP yielded the greatest Dice and Jaccard coefficients (87 and 80%, respectively; all p < 0.0001) between the co-registered participant gyri maps and the template gyri maps, demonstrating the goodness of the co-registration results. Furthermore, the greatest volume of group-level activation in the most number of functionally relevant regions was observed when the OPFAP was used. Importantly, group-level activations were not observed when using the standard pipeline. CONCLUSION: These results suggest that the OPFAP should be used for processing partial-coverage UHF-fMRI data for detecting high-resolution macroscopic blood oxygenation level-dependent activations.


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Neuroimagem , Adulto , Algoritmos , Feminino , Voluntários Saudáveis , Humanos , Imageamento Tridimensional , Masculino , Oxigênio/química , Software , Adulto Jovem
6.
Artif Organs ; 40(3): E12-24, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26416723

RESUMO

Successful visual prostheses require stable, long-term attachment. Epiretinal prostheses, in particular, require attachment methods to fix the prosthesis onto the retina. The most common method is fixation with a retinal tack; however, tacks cause retinal trauma, and surgical proficiency is important to ensure optimal placement of the prosthesis near the macula. Accordingly, alternate attachment methods are required. In this study, we detail a novel method of magnetic attachment for an epiretinal prosthesis using two prostheses components positioned on opposing sides of the retina. The magnetic attachment technique was piloted in a feline animal model (chronic, nonrecovery implantation). We also detail a new method to reliably control the magnet coupling force using heat. It was found that the force exerted upon the tissue that separates the two components could be minimized as the measured force is proportionately smaller at the working distance. We thus detail, for the first time, a surgical method using customized magnets to position and affix an epiretinal prosthesis on the retina. The position of the epiretinal prosthesis is reliable, and its location on the retina is accurately controlled by the placement of a secondary magnet in the suprachoroidal location. The electrode position above the retina is less than 50 microns at the center of the device, although there were pressure points seen at the two edges due to curvature misalignment. The degree of retinal compression found in this study was unacceptably high; nevertheless, the normal structure of the retina remained intact under the electrodes.


Assuntos
Imãs/química , Implantação de Prótese/métodos , Retina/cirurgia , Próteses Visuais/química , Animais , Gatos , Eletrodos Implantados , Temperatura Alta , Magnetismo/métodos , Desenho de Prótese , Retina/ultraestrutura
7.
Neurosurg Focus ; 40(5): E7, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27132528

RESUMO

Current standard practice requires an invasive approach to the recording of electroencephalography (EEG) for epilepsy surgery, deep brain stimulation (DBS), and brain-machine interfaces (BMIs). The development of endovascular techniques offers a minimally invasive route to recording EEG from deep brain structures. This historical perspective aims to describe the technical progress in endovascular EEG by reviewing the first endovascular recordings made using a wire electrode, which was followed by the development of nanowire and catheter recordings and, finally, the most recent progress in stent-electrode recordings. The technical progress in device technology over time and the development of the ability to record chronic intravenous EEG from electrode arrays is described. Future applications for the use of endovascular EEG in the preoperative and operative management of epilepsy surgery are then discussed, followed by the possibility of the technique's future application in minimally invasive operative approaches to DBS and BMI.


Assuntos
Estimulação Encefálica Profunda/métodos , Eletroencefalografia , Procedimentos Endovasculares/métodos , Epilepsia/terapia , Animais , Interfaces Cérebro-Computador , Eletroencefalografia/história , Eletroencefalografia/métodos , Eletroencefalografia/tendências , Procedimentos Endovasculares/tendências , História do Século XX , História do Século XXI , Humanos
8.
Dev Med Child Neurol ; 56(4): 378-85, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24102238

RESUMO

AIM: The aims of this study were to (1) determine whether an instrumented measure will reduce measurement error to less than 5° in children with cerebral palsy (CP), (2) determine agreement and reliability of this instrumented measure in both conscious and anaesthetized participants, and (3) compare the method with previously reported measures. METHOD: Thirty-four ambulant children (15 males, 19 females), aged 3 to 9 years, with spastic CP were studied in a tertiary-care paediatric hospital (21 with hemiplegia, 11 with diplegia, and two with quadriplegia). The majority of children functioned at Gross Motor Function Classification System level I (n=11) or II (n=18), with five children at level III. Ankle dorsiflexion at 50% bodyweight was photographed and measured. Each child was measured when conscious and when under mask anaesthesia by two experienced assessors. RESULTS: The standard error of measurement (SEM) ranged from 3.9° (anaesthetized; 95% confidence interval [CI] 3.3-4.0°) to 6.7° (conscious; 95% CI 5.3-8.0°). This compared favourably with previously reported dorsiflexion measures (SEM range 6.5-7.8°) in conscious children with CP. Intrarater reliability was good in both conditions (intraclass correlation coefficient [ICC]: range 0.95 [anaesthetized; 95% CI 0.92-0.98] to 0.86 [conscious; 95% CI 0.76-0.95]). The ICC for interrater reliability ranged from 0.87 (anaesthetized; 95% CI 0.81-0.93) to 0.65 (conscious; 95% CI 0.50-0.81). INTERPRETATION: Passive ankle dorsiflexion using an instrumented measure has face validity and may assist in the improvement of reproducibility under anaesthesia for clinical research. When an individual is conscious, this technique is not better than trained assessors using conventional goniometry reported in the literature and is not recommended for routine clinical use.


Assuntos
Anestésicos/farmacologia , Tornozelo/fisiopatologia , Paralisia Cerebral/patologia , Estado de Consciência/fisiologia , Reflexo/efeitos dos fármacos , Tornozelo/inervação , Fenômenos Biomecânicos , Toxinas Botulínicas Tipo A/uso terapêutico , Paralisia Cerebral/tratamento farmacológico , Paralisia Cerebral/fisiopatologia , Criança , Pré-Escolar , Avaliação da Deficiência , Feminino , Humanos , Modelos Lineares , Masculino , Reflexo/fisiologia , Reprodutibilidade dos Testes
9.
Artif Organs ; 38(6): E82-94, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24689741

RESUMO

Retinitis pigmentosa affects over 1.5 million people worldwide and is a leading cause of vision loss and blindness. While retinal prostheses have shown some success in restoring basic levels of vision, only generic, "one-size-fits-all" devices are currently being implanted. In this study, we used optical coherence tomography scans of the degenerated retina from 88 patients with retinitis pigmentosa to generate models of retinal thickness and curvature for the design of customized implants. We found the average retinal thickness at the fovea to be 152.9 ± 61.3 µm, increasing to a maximum retinal thickness of 250.9 ± 57.5 µm at a nasal eccentricity of 5°. These measures could be used to assist the development of custom-made penetrating electrodes to enhance and optimize epiretinal prostheses. From the retinal thickness measurements, we determined that the optimal length of penetrating electrodes to selectively stimulate retinal ganglion cell bodies and interneuron axons in the ganglion cell layer should be 30-100 µm, and to preferentially stimulate interneurons in the inner nuclear layer, electrodes should be 100-200 µm long. Electrodes greater than 200 µm long had the potential to penetrate through the retina into the choroid, which could cause devastating complications to the eye and should be avoided. The two- and three-dimensional models of retinal thickness developed in this study can be used to design patient-specific epiretinal implants that will help with safety and to optimize the efficacy of neuronal stimulation, ensuring the best functional performance of the device for patients.


Assuntos
Desenho Assistido por Computador , Desenho de Prótese , Implantação de Prótese/instrumentação , Retina/cirurgia , Retinose Pigmentar/cirurgia , Tomografia de Coerência Óptica , Próteses Visuais , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Simulação por Computador , Análise de Elementos Finitos , Humanos , Pessoa de Meia-Idade , Modelos Anatômicos , Valor Preditivo dos Testes , Retina/patologia , Retina/fisiopatologia , Retinose Pigmentar/patologia , Retinose Pigmentar/fisiopatologia , Acuidade Visual , Adulto Jovem
10.
Clin Exp Ophthalmol ; 42(7): 665-74, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24330322

RESUMO

BACKGROUND: Current surgical techniques for retinal prosthetic implantation require long and complicated surgery, which can increase the risk of complications and adverse outcomes. METHOD: The suprachoroidal position is known to be an easier location to access surgically, and so this study aimed to develop a surgical procedure for implanting a prototype suprachoroidal retinal prosthesis. The array implantation procedure was developed in 14 enucleated eyes. A full-thickness scleral incision was made parallel to the intermuscular septum and superotemporal to the lateral rectus muscle. A pocket was created in the suprachoroidal space, and the moulded electrode array was inserted. The scleral incision was closed and scleral anchor point sutured. In 9 of the 14 eyes examined, the device insertion was obstructed by the posterior ciliary neurovascular bundle. Subsequently, the position of this neurovascular bundle in 10 eyes was characterized. Implantation and lead routing procedure was then developed in six human cadavers. The array was tunnelled forward from behind the pinna to the orbit. Next, a lateral canthotomy was made. Lead fixation was established by creating an orbitotomy drilled in the frontal process of the zygomatic bone. The lateral rectus muscle was detached, and implantation was carried out. Finally, pinna to lateral canthus measurements were taken on 61 patients in order to determine optimal lead length. RESULTS: These results identified potential anatomical obstructions and informed the anatomical fitting of the suprachoroidal retinal prosthesis. CONCLUSION: As a result of this work, a straightforward surgical approach for accurate anatomical suprachoroidal array and lead placement was developed for clinical application.


Assuntos
Corioide/cirurgia , Procedimentos Cirúrgicos Oftalmológicos , Implantação de Prótese/métodos , Próteses Visuais , Cadáver , Feminino , Humanos , Masculino , Teste de Materiais , Retalhos Cirúrgicos , Técnicas de Sutura , Doadores de Tecidos
11.
Sci Rep ; 14(1): 7212, 2024 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-38532013

RESUMO

The endovascular neural interface provides an appealing minimally invasive alternative to invasive brain electrodes for recording and stimulation. However, stents placed in blood vessels have long been known to affect blood flow (haemodynamics) and lead to neointimal growth within the blood vessel. Both the stent elements (struts and electrodes) and blood vessel wall geometries can affect the mechanical environment on the blood vessel wall, which could lead to unfavourable vascular remodelling after stent placement. With increasing applications of stents and stent-like neural interfaces in venous blood vessels in the brain, it is necessary to understand how stents affect blood flow and tissue growth in veins. We explored the haemodynamics of a stent-mounted neural interface in a blood vessel model. Results indicated that blood vessel deformation and tapering caused a substantial change to the lumen geometry and the haemodynamics. The neointimal proliferation was evaluated in sheep implanted with an endovascular neural interface. Analysis showed a negative correlation with the mean Wall Shear Stress pattern. The results presented here indicate that the optimal stent oversizing ratio must be considered to minimise the haemodynamic impact of stenting.


Assuntos
Hemodinâmica , Stents , Animais , Ovinos , Circulação Coronária/fisiologia , Neointima
12.
JAMA Neurol ; 80(3): 270-278, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36622685

RESUMO

Importance: Brain-computer interface (BCI) implants have previously required craniotomy to deliver penetrating or surface electrodes to the brain. Whether a minimally invasive endovascular technique to deliver recording electrodes through the jugular vein to superior sagittal sinus is safe and feasible is unknown. Objective: To assess the safety of an endovascular BCI and feasibility of using the system to control a computer by thought. Design, Setting, and Participants: The Stentrode With Thought-Controlled Digital Switch (SWITCH) study, a single-center, prospective, first in-human study, evaluated 5 patients with severe bilateral upper-limb paralysis, with a follow-up of 12 months. From a referred sample, 4 patients with amyotrophic lateral sclerosis and 1 with primary lateral sclerosis met inclusion criteria and were enrolled in the study. Surgical procedures and follow-up visits were performed at the Royal Melbourne Hospital, Parkville, Australia. Training sessions were performed at patients' homes and at a university clinic. The study start date was May 27, 2019, and final follow-up was completed January 9, 2022. Interventions: Recording devices were delivered via catheter and connected to subcutaneous electronic units. Devices communicated wirelessly to an external device for personal computer control. Main Outcomes and Measures: The primary safety end point was device-related serious adverse events resulting in death or permanent increased disability. Secondary end points were blood vessel occlusion and device migration. Exploratory end points were signal fidelity and stability over 12 months, number of distinct commands created by neuronal activity, and use of system for digital device control. Results: Of 4 patients included in analyses, all were male, and the mean (SD) age was 61 (17) years. Patients with preserved motor cortex activity and suitable venous anatomy were implanted. Each completed 12-month follow-up with no serious adverse events and no vessel occlusion or device migration. Mean (SD) signal bandwidth was 233 (16) Hz and was stable throughout study in all 4 patients (SD range across all sessions, 7-32 Hz). At least 5 attempted movement types were decoded offline, and each patient successfully controlled a computer with the BCI. Conclusions and Relevance: Endovascular access to the sensorimotor cortex is an alternative to placing BCI electrodes in or on the dura by open-brain surgery. These final safety and feasibility data from the first in-human SWITCH study indicate that it is possible to record neural signals from a blood vessel. The favorable safety profile could promote wider and more rapid translation of BCI to people with paralysis. Trial Registration: ClinicalTrials.gov Identifier: NCT03834857.


Assuntos
Interfaces Cérebro-Computador , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Encéfalo , Córtex Cerebral , Paralisia/etiologia , Estudos Prospectivos
13.
J Neural Eng ; 19(5)2022 10 28.
Artigo em Inglês | MEDLINE | ID: mdl-36240737

RESUMO

Objective.The aim of this work was to assess vascular remodeling after the placement of an endovascular neural interface (ENI) in the superior sagittal sinus (SSS) of sheep. We also assessed the efficacy of neural recording using an ENI.Approach.The study used histological analysis to assess the composition of the foreign body response. Micro-CT images were analyzed to assess the profiles of the foreign body response and create a model of a blood vessel. Computational fluid dynamic modeling was performed on a reconstructed blood vessel to evaluate the blood flow within the vessel. Recording of brain activity in sheep was used to evaluate efficacy of neural recordings.Main results.Histological analysis showed accumulated extracellular matrix material in and around the implanted ENI. The extracellular matrix contained numerous macrophages, foreign body giant cells, and new vascular channels lined by endothelium. Image analysis of CT slices demonstrated an uneven narrowing of the SSS lumen proportional to the stent material within the blood vessel. However, the foreign body response did not occlude blood flow. The ENI was able to record epileptiform spiking activity with distinct spike morphologies.Significance. This is the first study to show high-resolution tissue profiles, the histological response to an implanted ENI and blood flow dynamic modeling based on blood vessels implanted with an ENI. The results from this study can be used to guide surgical planning and future ENI designs; stent oversizing parameters to blood vessel diameter should be considered to minimize detrimental vascular remodeling.


Assuntos
Procedimentos Endovasculares , Corpos Estranhos , Animais , Ovinos , Remodelação Vascular , Stents , Seio Sagital Superior
14.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 5686-5689, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34892412

RESUMO

AIM: Brain-Computer Interfaces (BCIs) hold promise to provide people with partial or complete paralysis, the ability to control assistive technology. This study reports offline classification of imagined and executed movements of the upper and lower limb in one participant with multiple sclerosis and people with no limb function deficits. METHODS: We collected neural signals using electroencephalography (EEG) while participants performed executed and imagined motor tasks as directed by prompts shown on a screen. RESULTS: Participants with no limb function attained >70% decoding accuracy on their best-imagined task compared to rest and on at-least one task comparison. The participant with multiple sclerosis also achieved accuracies within the range of participants with no limb function loss.Clinical Relevance - While only one case study is provided it was promising that the participant with MS was able to achieve comparable classification to that of the seven healthy controls. Further studies are needed to assess whether people suffering from MS may be able to use a BCI to improve their quality of life.


Assuntos
Interfaces Cérebro-Computador , Esclerose Múltipla , Eletroencefalografia , Estudos de Viabilidade , Humanos , Qualidade de Vida
15.
J Neurointerv Surg ; 13(2): 102-108, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33115813

RESUMO

BACKGROUND: Implantable brain-computer interfaces (BCIs), functioning as motor neuroprostheses, have the potential to restore voluntary motor impulses to control digital devices and improve functional independence in patients with severe paralysis due to brain, spinal cord, peripheral nerve or muscle dysfunction. However, reports to date have had limited clinical translation. METHODS: Two participants with amyotrophic lateral sclerosis (ALS) underwent implant in a single-arm, open-label, prospective, early feasibility study. Using a minimally invasive neurointervention procedure, a novel endovascular Stentrode BCI was implanted in the superior sagittal sinus adjacent to primary motor cortex. The participants undertook machine-learning-assisted training to use wirelessly transmitted electrocorticography signal associated with attempted movements to control multiple mouse-click actions, including zoom and left-click. Used in combination with an eye-tracker for cursor navigation, participants achieved Windows 10 operating system control to conduct instrumental activities of daily living (IADL) tasks. RESULTS: Unsupervised home use commenced from day 86 onwards for participant 1, and day 71 for participant 2. Participant 1 achieved a typing task average click selection accuracy of 92.63% (100.00%, 87.50%-100.00%) (trial mean (median, Q1-Q3)) at a rate of 13.81 (13.44, 10.96-16.09) correct characters per minute (CCPM) with predictive text disabled. Participant 2 achieved an average click selection accuracy of 93.18% (100.00%, 88.19%-100.00%) at 20.10 (17.73, 12.27-26.50) CCPM. Completion of IADL tasks including text messaging, online shopping and managing finances independently was demonstrated in both participants. CONCLUSION: We describe the first-in-human experience of a minimally invasive, fully implanted, wireless, ambulatory motor neuroprosthesis using an endovascular stent-electrode array to transmit electrocorticography signals from the motor cortex for multiple command control of digital devices in two participants with flaccid upper limb paralysis.


Assuntos
Atividades Cotidianas , Interfaces Cérebro-Computador , Neuroestimuladores Implantáveis , Córtex Motor/fisiologia , Paralisia/terapia , Índice de Gravidade de Doença , Atividades Cotidianas/psicologia , Idoso , Interfaces Cérebro-Computador/psicologia , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Córtex Motor/diagnóstico por imagem , Paralisia/diagnóstico por imagem , Paralisia/fisiopatologia , Estudos Prospectivos
16.
Front Neurol ; 11: 351, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32390937

RESUMO

Endovascular neuromodulation is an emerging technology that represents a synthesis between interventional neurology and neural engineering. The prototypical endovascular neural interface is the StentrodeTM, a stent-electrode array which can be implanted into the superior sagittal sinus via percutaneous catheter venography, and transmits signals through a transvenous lead to a receiver located subcutaneously in the chest. Whilst the StentrodeTM has been conceptually validated in ovine models, questions remain about the long term viability and safety of this device in human recipients. Although technical precedence for venous sinus stenting already exists in the setting of idiopathic intracranial hypertension, long term implantation of a lead within the intracranial veins has never been previously achieved. Contrastingly, transvenous leads have been successfully employed for decades in the setting of implantable cardiac pacemakers and defibrillators. In the current absence of human data on the StentrodeTM, the literature on these structurally comparable devices provides valuable lessons that can be translated to the setting of endovascular neuromodulation. This review will explore this literature in order to understand the potential risks of the StentrodeTM and define avenues where further research and development are necessary in order to optimize this device for human application.

17.
Neurosurgery ; 86(2): E108-E117, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31361011

RESUMO

Brain-computer interface (BCI) technology is rapidly developing and changing the paradigm of neurorestoration by linking cortical activity with control of an external effector to provide patients with tangible improvements in their ability to interact with the environment. The sensor component of a BCI circuit dictates the resolution of brain pattern recognition and therefore plays an integral role in the technology. Several sensor modalities are currently in use for BCI applications and are broadly either electrode-based or functional neuroimaging-based. Sensors vary in their inherent spatial and temporal resolutions, as well as in practical aspects such as invasiveness, portability, and maintenance. Hybrid BCI systems with multimodal sensory inputs represent a promising development in the field allowing for complimentary function. Artificial intelligence and deep learning algorithms have been applied to BCI systems to achieve faster and more accurate classifications of sensory input and improve user performance in various tasks. Neurofeedback is an important advancement in the field that has been implemented in several types of BCI systems by showing users a real-time display of their recorded brain activity during a task to facilitate their control over their own cortical activity. In this way, neurofeedback has improved BCI classification and enhanced user control over BCI output. Taken together, BCI systems have progressed significantly in recent years in terms of accuracy, speed, and communication. Understanding the sensory components of a BCI is essential for neurosurgeons and clinicians as they help advance this technology in the clinical setting.


Assuntos
Algoritmos , Interfaces Cérebro-Computador/tendências , Encéfalo/fisiologia , Inteligência Artificial/tendências , Encéfalo/diagnóstico por imagem , Eletrocorticografia/métodos , Eletrocorticografia/tendências , Eletrodos Implantados , Eletroencefalografia/métodos , Eletroencefalografia/tendências , Humanos , Neuroimagem/métodos , Neuroimagem/tendências
18.
Front Behav Neurosci ; 14: 77, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32581737

RESUMO

There is evidence to suggest that motor execution and motor imagery both involve planning and execution of the same motor plan, however, in the latter the output is inhibited. Currently, little is known about the underlying neural mechanisms of motor output inhibition during motor imagery. Uncovering the distinctive characteristics of motor imagery may help us better understand how we abstract complex thoughts and acquire new motor skills. The current study aimed to dissociate the cognitive processes involved in two distinct inhibitory mechanisms of motor inhibition and motor imagery restraint. Eleven healthy participants engaged in an imagined GO/NO-GO task during a 7 Tesla fMRI experiment. Participants planned a specific type of motor imagery, then, imagined the movements during the GO condition and restrained from making a response during the NO-GO condition. The results revealed that specific sub-regions of the supplementary motor cortex (SMC) and the primary motor cortex (M1) were recruited during the imagination of specific movements and information flowed from the SMC to the M1. Such condition-specific recruitment was not observed when motor imagery was restrained. Instead, general recruitment of the posterior parietal cortex (PPC) was observed, while the BOLD activity in the SMC and the M1 decreased below the baseline at the same time. Information flowed from the PPC to the SMC, and recurrently between the M1 and the SMC, and the M1 and the PPC. These results suggest that motor imagery involves task-specific motor output inhibition partly imposed by the SMC to the M1, while the PPC globally inhibits motor plans before they are passed on for execution during the restraint of responses.

19.
J Neural Eng ; 17(4): 045014, 2020 08 05.
Artigo em Inglês | MEDLINE | ID: mdl-32659750

RESUMO

OBJECTIVE: Due to their increased proximity to retinal ganglion cells (RGCs), epiretinal visual prostheses present the opportunity for eliciting phosphenes with low thresholds through direct RGC activation. This study characterised the in vivo performance of a novel prototype monolithic epiretinal prosthesis, containing Nitrogen incorporated ultrananocrystalline (N-UNCD) diamond electrodes. APPROACH: A prototype implant containing up to twenty-five 120 × 120 µm N-UNCD electrodes was implanted into 16 anaesthetised cats and attached to the retina either using a single tack or via magnetic coupling with a suprachoroidally placed magnet. Multiunit responses to retinal stimulation using charge-balanced biphasic current pulses were recorded acutely in the visual cortex using a multichannel planar array. Several stimulus parameters were varied including; the stimulating electrode, stimulus polarity, phase duration, return configuration and the number of electrodes stimulated simultaneously. MAIN RESULTS: The rigid nature of the device and its form factor necessitated complex surgical procedures. Surgeries were considered successful in 10/16 animals and cortical responses to single electrode stimulation obtained in eight animals. Clinical imaging and histological outcomes showed severe retinal trauma caused by the device in situ in many instances. Cortical measures were found to significantly depend on the surgical outcomes of individual experiments, phase duration, return configuration and the number of electrodes stimulated simultaneously, but not stimulus polarity. Cortical thresholds were also found to increase over time within an experiment. SIGNIFICANCE: The study successfully demonstrated that an epiretinal prosthesis containing diamond electrodes could produce cortical activity with high precision, albeit only in a small number of cases. Both surgical approaches were highly challenging in terms of reliable and consistent attachment to and stabilisation against the retina, and often resulted in severe retinal trauma. There are key challenges (device form factor and attachment technique) to be resolved for such a device to progress towards clinical application, as current surgical techniques are unable to address these issues.


Assuntos
Diamante , Próteses Visuais , Animais , Gatos , Estimulação Elétrica , Eletrodos , Eletrodos Implantados , Estudos de Viabilidade , Retina
20.
IEEE Trans Biomed Eng ; 66(3): 675-681, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30004867

RESUMO

OBJECTIVE: Neural prostheses are improving the quality of life for those suffering from neurological impairments. Electrocorticography electrodes located in subdural, epidural, and intravascular positions show promise as long-term neural prostheses. However, chronic implantation affects the electrochemical environments of these arrays. METHODS: In the present work, the effect of electrode location on the electrochemical properties of the interface was compared. The impedances of the electrode arrays were measured using electrochemical impedance spectroscopy in vitro in saline and in vivo four-week postimplantation. RESULTS: There was not a significant effect of electrode location (subdural, intravascular, or epidural) on the impedance magnitude, and the effect of the electrode size on the impedance magnitude was frequency dependent. There was a frequency-dependent statistically significant effect of electrode location and electrode size on the phase angles of the three arrays. The subdural and epidural arrays showed phase shifts closer to -90° indicating the capacitive nature of the interface in these locations. The impact of placing electrodes within a blood vessel and adjacent to the blood vessel wall was most obvious when looking at the phase responses at frequencies below 10 kHz. CONCLUSION: Our results show that intravascular electrodes, like those in subdural and epidural positions, show electrical properties that are suitable for recording. These results provide support for the use of intravascular arrays in clinically relevant neural prostheses and diagnostic devices. SIGNIFICANCE: Comparison of electrochemical impedance of the epidural, intravascular, and subdural electrode array showed that all three locations are possible placement options, since impedances are in comparable ranges.


Assuntos
Espectroscopia Dielétrica/métodos , Impedância Elétrica , Próteses Neurais , Animais , Encéfalo/irrigação sanguínea , Encéfalo/fisiologia , Procedimentos Endovasculares , Espaço Epidural/fisiologia , Ovinos
SELEÇÃO DE REFERÊNCIAS