Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 95(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38456758

RESUMO

Multigap cavities are used extensively in linear accelerators to achieve velocities up to a few percent of the speed of light, driving nuclear physics research around the world. Unlike for single-gap structures, there is no closed-form expression to calculate the output beam parameters from the cavity voltage and phase. To overcome this, we propose to use a method based on the integration of the first and second moments of the beam distribution through the axially symmetric time-dependent fields of the cavity. A beam-based calibration between the model's electric field scaling and the machine's rf amplitudes is presented, yielding a fast online energy change method, returning cavity amplitude and phase necessary for a desired output beam energy and energy spread. The method is validated with 23Na6+ beam energy measurements.

2.
Rev Sci Instrum ; 92(11): 113306, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34852560

RESUMO

The upcoming commissioning of the superconducting (SC) continuous wave Helmholtz linear accelerators first of series cryomodule is going to demand precise alignment of the four internal SC cavities and two SC solenoids. For optimal results, a beam-based alignment method is used to reduce the misalignment of the whole cryomodule, as well as its individual components. A symmetric beam of low transverse emittance is required for this method, which is to be formed by a collimation system. It consists of two separate plates with milled slits, aligned in the horizontal and vertical direction. The collimation system and alignment measurements are proposed, investigated, and realized. The complete setup of this system and its integration into the existing environment at the GSI High Charge State Injector are presented, as well as the results of the recent reference measurements.

3.
Phys Rev Lett ; 94(17): 172501, 2005 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-15904283

RESUMO

We report on the first radioactive beam experiment performed at the recently commissioned REX-ISOLDE facility at CERN in conjunction with the highly efficient gamma spectrometer MINIBALL. Using 30Mg ions accelerated to an energy of 2.25 MeV/u together with a thin (nat)Ni target, Coulomb excitation of the first excited 2+ states of the projectile and target nuclei well below the Coulomb barrier was observed. From the measured relative deexcitation gamma-ray yields the B(E2;0(+)gs-->2(+)1) value of 30Mg was determined to be 241(31)e2 fm4. Our result is lower than values obtained at projectile fragmentation facilities using the intermediate-energy Coulomb excitation method, and confirms the theoretical conjecture that the neutron-rich magnesium isotope 30Mg resides outside the "island of inversion."

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA