Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
J Clin Psychopharmacol ; 43(4): 339-349, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37335211

RESUMO

BACKGROUND: Serotonergic hallucinogens and cannabinoids may alter the recognition of emotions in facial expressions (REFE). Cannabidiol (CBD) attenuates the psychoactive effects of the cannabinoid-1 agonist tetrahydrocannabinol. Ayahuasca is a dimethyltryptamine-containing hallucinogenic decoction. It is unknown if CBD may moderate and attenuate the effects of ayahuasca on REFE. PROCEDURES: Seventeen healthy volunteers participated in a 1-week preliminary parallel-arm, randomized controlled trial for 18 months. Volunteers received a placebo or 600 mg of oral CBD followed by oral ayahuasca (1 mL/kg) 90 minutes later. Primary outcomes included REFE and empathy tasks (coprimary outcome). Tasks were performed at baseline and 6.5 hours, 1 and 7 days after the interventions. Secondary outcome measures included subjective effects, tolerability, and biochemical assessments. RESULTS: Significant reductions (all P values <0.05) only in reaction times were observed in the 2 tasks in both groups, without between-group differences. Furthermore, significant reductions in anxiety, sedation, cognitive deterioration, and discomfort were observed in both groups, without between-group differences. Ayahuasca, with or without CBD, was well tolerated, producing mainly nausea and gastrointestinal discomfort. No clinically significant effects were observed on cardiovascular measurements and liver enzymes. CONCLUSIONS: There was no evidence of interactive effects between ayahuasca and CBD. The safety of separate and concomitant drug intake suggests that both drugs could be applied to clinical populations with anxiety disorders and in further trials with larger samples to confirm findings.


Assuntos
Banisteriopsis , Canabidiol , Humanos , Canabidiol/efeitos adversos , Cognição Social , Estudos de Viabilidade , Dronabinol/farmacologia , Agonistas de Receptores de Canabinoides , Método Duplo-Cego
2.
Anal Bioanal Chem ; 415(18): 4003-4021, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36877264

RESUMO

Alzheimer's disease (AD), a neurological disorder, is a major public health concern and the most common form of dementia. Its typical symptoms include memory loss, confusion, changes in personality, and cognitive impairment, which result in patients gradually losing independence. Over the last decades, some studies have focused on searching for effective biomarkers as early diagnostic indicators of AD. Amyloid-ß (Aß) peptides have been consolidated as reliable AD biomarkers and have been incorporated into modern diagnostic research criteria. However, quantitative analysis of Aß peptides in biological samples remains a challenge because both the sample and the physical-chemical properties of these peptides are complex. During clinical routine, Aß peptides are measured in the cerebrospinal fluid by immunoassays, but the availability of a specific antibody is critical-in some cases, an antibody may not exist, or its specificity may be inadequate, leading to low sensitivity and false results. HPLC-MS/MS has been reported as a sensitive and selective method for determining different fragments of Aß peptides in biological samples simultaneously. Developments in sample preparation techniques (preconcentration platforms) such as immunoprecipitation, 96-well plate SPME, online SPME, and fiber-in-tube SPME have enabled not only effective enrichment of Aß peptides present at trace levels in biological samples, but also efficient exclusion of interferents from the sample matrix (sample cleanup). This high extraction efficiency has provided MS platforms with higher sensitivity. Recently, methods affording LLOQ values as low as 5 pg mL-1 have been reported. Such low LLOQ values are adequate for quantifying Aß peptides in complex matrixes including cerebrospinal fluid (CSF) and plasma samples. This review summarizes the advances in mass spectrometry (MS)-based methods for quantifying Aß peptides and covers the period 1992-2022. Important considerations regarding the development of the HPLC-MS/MS method such as the sample preparation step, optimization of the HPLC-MS/MS parameters, and matrix effects are described. Clinical applications, difficulties related to analysis of plasma samples, and future trends of these MS/MS-based methods are also discussed.


Assuntos
Doença de Alzheimer , Peptídeos beta-Amiloides , Humanos , Peptídeos beta-Amiloides/química , Espectrometria de Massas em Tandem , Cromatografia Líquida de Alta Pressão , Doença de Alzheimer/diagnóstico , Anticorpos , Biomarcadores/líquido cefalorraquidiano , Fragmentos de Peptídeos/química
3.
Hum Psychopharmacol ; 37(4): e2834, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35107855

RESUMO

OBJECTIVE: To assess endocannabinoid (anandamide, AEA; 2-arachidonoylglycerol, 2-AG) plasma levels in healthy volunteers and in volunteers with social anxiety disorder (SAD) after a single oral dose of ayahuasca or placebo. METHODS: Post hoc analysis of endocannabinoid plasma levels (baseline, 90 and 240 min after drug intake) from two parallel-group, randomized, placebo-controlled trials. In Study 1, 20 healthy volunteers ingested ayahuasca (average 1.58 mg/ml dimethyltryptamine (DMT)) or placebo, and in Study 2, 17 volunteers with SAD received ayahuasca (average 0.680 mg/ml DMT) or placebo. RESULTS: A significant difference was observed in AEA concentrations in Study 2 after ayahuasca intake (Χ2 (2) = 6.5, p = 0.03, Friedman test), and near significant differences (increases) were observed between baseline and 90 (Z = 0, p = 0.06, Wilcoxon test) and 240 (Z = 10, p = 0.06) minutes after ayahuasca intake. CONCLUSIONS: Although our findings suggest that ayahuasca could modulate AEA levels in SAD patients, the high interindividual variability in both trials and the small samples preclude definitive conclusions. More research with larger samples is needed to better understand the effects of ayahuasca and other hallucinogens in the endocannabinoid system.


Assuntos
Banisteriopsis , Alucinógenos , Fobia Social , Endocanabinoides , Voluntários Saudáveis , Humanos , N,N-Dimetiltriptamina/farmacologia , Fobia Social/tratamento farmacológico
4.
J Sep Sci ; 44(8): 1621-1632, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33387419

RESUMO

This manuscript describes the development of an innovative method to determine cannabinoids (cannabidiol and tetrahydrocannabinol) in human plasma samples by pipette tip micro-solid phase extraction and liquid chromatography-mass spectrometry/mass spectromtery. An octyl-functionalized hybrid silica monolith, which had been synthesized and characterized, was used as a selective stationary phase. The octyl-functionalized hybrid silica monoliths presented high permeability and adequate mechanical strength. The micro-solid phase extraction variables (sample pH, draw-eject cycles, solvent for phase clean-up, and desorption conditions) were investigated to improve not only the selectivity but also the sorption capacity. The method was linear at concentrations ranging from the lower limit of quantification (10.00 ng/mL) to the upper limit of quantification (150.0 ng/mL). The lack of fit and homoscedasticity tests, as well as the determination coefficients (r2 greater than 0.995), certified that linearity was adequate. The precision assays presented coefficient of variation values lower than 15%, and the accuracy tests provided relative error values ranging from 3.2 to 14%. Neither significant carry-over nor matrix effects were detected. Therefore, the pipette tip micro-solid phase extraction/liquid chromatography-mass spectrometry/mass spectrometry method has demonstrated to be adequate to determine cannabidiol and tetrahydrocannabinol simultaneously in plasma samples for therapeutic drug monitoring of patients undergoing treatment with cannabinoids.


Assuntos
Canabidiol/sangue , Dronabinol/sangue , Dióxido de Silício/química , Microextração em Fase Sólida , Cromatografia Líquida de Alta Pressão , Humanos , Tamanho da Partícula , Propriedades de Superfície , Espectrometria de Massas em Tandem
5.
J Sep Sci ; 44(8): 1662-1693, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33528909

RESUMO

In-tube solid-phase microextraction with a capillary column as extraction device can be directly coupled with high-performance liquid chromatography systems (HPLC). The in-tube solid-phase microextraction technique has been continuously developed since it was introduced in 1997. New couplings have also been evaluated on the basis of state-of-the-art HPLC instruments. Different types of capillaries (wall-coated open tubular, porous layer open tubular, sorbent-packed, porous monolithic rods, or fiber-packed) with selective stationary phases (monoliths, magnetic nanoparticles, conducting polymers, restricted access materials, ionic liquids, carbon, deep eutectic solvents, and hybrid materials) have been developed to boost in-tube solid-phase microextraction performance (sorption capacity and selectivity). This technique has been successfully applied to analyze biological samples (serum, plasma, whole blood, hair, urine, milk, skin, and saliva) for therapeutic drug monitoring, to study biomarkers, to detect illicit drugs, to conduct metabolomics studies, and to assess exposure to drugs. This review describes current advances in in-tube solid-phase microextraction extraction devices and their application in bioanalysis.


Assuntos
Carbono/química , Líquidos Iônicos/química , Microextração em Fase Sólida , Cromatografia Líquida de Alta Pressão , Tamanho da Partícula , Porosidade , Solventes/química , Propriedades de Superfície
6.
J Neural Transm (Vienna) ; 127(10): 1359-1367, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32797288

RESUMO

Levodopa-induced dyskinesias (LID) in Parkinson's disease (PD) are frequent complications, and the endocannabinoid system has a role on its pathophysiology. To test the hypothesis that the functioning of the endocannabinoid system would be altered in PD and in LID by measuring plasma and CSF levels of α-N-arachidonoylethanolamine (AEA) and 2-arachidonoyl-glycerol (2-AG) in patients with PD with and without LID and in healthy controls. Blood and CSF samples were collected from 20 healthy controls, 23 patients with PD without LID, and 24 patients with PD with LID. The levels of AEA and 2-AG were measured using a highly sensitive column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry method. When pooled together, patients with PD had lower plasma and CSF levels of 2-AG and higher CSF levels of AEA compared to healthy controls (Mann-Whitney statistics = 303.0, p = 0.02). Patients with PD without LID had lower CSF levels of 2-AG (Kruskal-Wallis statistics = 7.76, p = 0.02) and higher CSF levels of AEA levels than healthy controls (Kruskal-Wallis statistics = 8.81, p = 0.01). The findings suggest that the endocannabinoid system participates in the pathophysiology of PD symptoms, but its role in the pathophysiology of LID is still unclear.


Assuntos
Discinesia Induzida por Medicamentos , Doença de Parkinson , Antiparkinsonianos/efeitos adversos , Cromatografia Líquida de Alta Pressão , Endocanabinoides , Humanos , Levodopa/efeitos adversos , Doença de Parkinson/tratamento farmacológico
7.
Anal Bioanal Chem ; 412(11): 2465-2475, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32025768

RESUMO

This manuscript describes the development of the restricted access carbon nanotube (RACNT) as a selective stationary phase for microextraction by packed sorbent (MEPS) to determine antipsychotics (chlorpromazine, clozapine, olanzapine, and quetiapine) in untreated plasma samples from schizophrenic patients by ultra-high liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The synthesis was achieved by chemically covering commercial multi-walled carbon nanotubes with bovine serum albumin (BSA) to subsequently pack the material in a polyethylene conical tube (1000 µL). The RACNTs' sorbents were able to exclude about 97% of the plasma proteins, maintaining the same performance for about 100 assays. The MEPS variables (sample pH, draw-eject cycles, desorption and phase cleanup) were evaluated to improve sensibility and selectivity. The MEPS/UHPLC-MS/MS method was linear at concentrations ranging from the lower limit of quantification (10.0 ng mL-1) to the upper limit of quantification (200-700 ng mL-1) with coefficients of determinations higher than 0.99. The precision assays presented relative standard deviation (RSD) values lower than 13%, and the accuracy assays presented relative error (RE) values that ranged from - 8.01 to 11.53%. Neither significant matrix effects nor carryover was observed. The developed method was successfully applied to determine antipsychotics drugs for therapeutic drug monitoring of schizophrenic patients.


Assuntos
Antipsicóticos/sangue , Monitoramento de Medicamentos/métodos , Nanotubos de Carbono/química , Microextração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Antipsicóticos/isolamento & purificação , Cromatografia Líquida de Alta Pressão/métodos , Humanos , Limite de Detecção , Esquizofrenia/tratamento farmacológico
8.
Anal Chem ; 91(8): 4969-4974, 2019 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-30901521

RESUMO

To achieve high separation power of complex samples using multidimensional gas chromatography (MDGC), the selectivity of the employed stationary phases is crucial. The nonpolar × polar column combination remains the most popular column set used in MDGC. However, resolution of mixtures containing light analytes possessing very similar properties remains a formidable challenge. The development of stationary phases that offer unique separation mechanisms have the potential to significantly improve MDGC separations, particularly in resolving coeluting peaks in complex samples. For the first time, a stationary phase containing silver(I) ions was successfully designed and employed as a second-dimension column using comprehensive two-dimensional gas chromatography (GC × GC) for the separation of mixtures containing alkynes, dienes, terpenes, esters, aldehydes, and ketones. Compared with a widely used nonpolar and polar column set, the silver-based column exhibited superior performance by providing better chromatographic resolution of coeluting compounds. A mixture of unsaturated fatty acids was successfully separated using a GC × GC method in which the elution order in the second dimension was highly dependent on the number of double bonds within the analytes.

9.
Molecules ; 24(2)2019 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-30654481

RESUMO

This manuscript describes a sensitive, selective, and online in-tube solid-phase microextraction coupled with an ultrahigh performance liquid chromatography-tandem mass spectrometry (in-tube SPME-UHPLC-MS/MS) method to determine chlopromazine, clozapine, quetiapine, olanzapine, and their metabolites in plasma samples from schizophrenic patients. Organic poly(butyl methacrylate-co-ethylene glycol dimethacrylate) monolith was synthesized on the internal surface of a fused silica capillary (covalent bonds) for in-tube SPME. Analyte extraction and analysis was conducted by connecting the monolithic capillary to an UHPLC-MS/MS system. The monolith was characterized by scanning electron microscopy (SEM) and Fourier transform infrared spectrometry (FTIR). The developed method presented adequate linearity for all the target antipsychotics: R² was higher than 0.9975, lack-of-fit ranged from 0.115 to 0.955, precision had variation coefficients lower than 14.2%, and accuracy had relative standard error values ranging from -13.5% to 14.6%, with the exception of the lower limit of quantification (LLOQ). The LLOQ values in plasma samples were 10 ng mL-1 for all analytes. The developed method was successfully applied to determine antipsychotics and their metabolites in plasma samples from schizophrenic patients.


Assuntos
Antipsicóticos/sangue , Metabolômica/métodos , Esquizofrenia/sangue , Microextração em Fase Sólida/métodos , Clorpromazina/sangue , Cromatografia Líquida de Alta Pressão , Clozapina/sangue , Humanos , Olanzapina/sangue , Fumarato de Quetiapina/sangue , Esquizofrenia/tratamento farmacológico , Espectrometria de Massas em Tandem
10.
Anal Bioanal Chem ; 409(14): 3587-3596, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28337517

RESUMO

This study reports a fast, sensitive, and selective column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method to determine the endocannabinoids (eCBs), anandamide (AEA), and 2-arachidonoylglycerol (2-AG) in plasma samples. This bidimensional system used a restricted access media column (RP-8 ADS, 25 mm × 4 mm × 25 µM) in the first dimension and a core-shell Kinetex C18 (100 mm × 2, 1.7 mm × 1 µM) column in the second dimension, followed by detection in a mass spectrometer triple quadrupole (multiple reactions monitoring mode) operating in the positive mode. RP-8 ADS was used for trace enrichment of eCBs (reverse phase partitioning) and macromolecular matrix size exclusion; the core-shell column was used for the chromatographic separation. The column switching UHPLC-MS/MS method presented a linear range spanning from 0.1 ng mL-1 (LOQ) to 6 ng mL-1 for AEA and from 0.04 ng mL-1 (LOQ) to 10 ng mL-1 for 2-AG. Excluding the LLOQ values, the precision assays provided coefficients of variation lower than 8% and accuracy with relative standard error values lower than 14%. Neither carryover nor matrix effects were detected. This high-throughput column switching method compared to conventional methods is time saving as it involves fewer steps, consumes less solvent, and presents lower LLOQ. The column switching UHPLC-MS/MS method was successfully applied to determine AEA and 2-AG in plasma samples obtained from Alzheimer's disease patients. Graphical abstract A column switching ultra high-performance liquid chromatography-tandem mass spectrometry method using RP-8 ADS column and core shell column to determine endocannabinoids in plasma samples.


Assuntos
Ácidos Araquidônicos/sangue , Cromatografia Líquida de Alta Pressão/métodos , Endocanabinoides/sangue , Glicerídeos/sangue , Alcamidas Poli-Insaturadas/sangue , Espectrometria de Massas em Tandem/métodos , Doença de Alzheimer/sangue , Cromatografia Líquida de Alta Pressão/instrumentação , Desenho de Equipamento , Humanos , Limite de Detecção , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/instrumentação
11.
Am J Orthod Dentofacial Orthop ; 151(3): 477-483, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28257732

RESUMO

INTRODUCTION: The objectives of this study were to quantify in vitro the Bisphenol A (BPA) release from 5 orthodontic composites and to assess in vivo the BPA level in patients' saliva and urine after bracket bonding with an orthodontic adhesive system. METHODS: For the in-vitro portion of this study, 5 orthodontic composites were evaluated: Eagle Spectrum (American Orthodontics, Sheboygan, Wis), Enlight (Ormco, Orange, Calif), Light Bond (Reliance Orthodontic Products, Itasca, Ill), Mono Lok II (Rocky Mountain Orthodontics, Denver, Colo), and Transbond XT (3M Unitek, Monrovia, Calif). Simulating intraoral conditions, the specimens were immersed in a water/ethanol solution, and the BPA (ng.g-1) liberation was measured after 30 minutes, 24 hours, 1 day, 1 week, and 1 month by the gas chromatography system coupled with mass spectrometry. Twenty patients indicated for fixed orthodontic treatment participated in the in-vivo study. Saliva samples were collected before bracket bonding and then 30 minutes, 24 hours, 1 day, 1 week, and 1 month after bonding the brackets. Urine samples were collected before bonding and then at 1 day, 1 week, and 1 month after bonding. The results were analyzed statistically using analysis of variance and Tukey posttest, with a significance level of 5%. RESULTS: All composites evaluated in vitro released small amounts of BPA. Enlight composite showed the greatest release, at 1 month. Regarding the in-vivo study, the mean BPA level in saliva increased significantly only at 30 minutes after bonding in comparison with measurements recorded before bonding. CONCLUSIONS: All orthodontic composites released BPA in vitro. Enlight and Light Bond had, respectively, the highest and lowest BPA releases in vitro. The in-vivo experiment showed that bracket bonding with the Transbond XT orthodontic adhesive system resulted in increased BPA levels in saliva and urine. The levels were significant but still lower than the reference dose for daily ingestion.


Assuntos
Compostos Benzidrílicos/análise , Cimentos Dentários/química , Fenóis/análise , Cimentos de Resina/química , Saliva/química , Urina/química , Cromatografia Gasosa , Resinas Compostas , Humanos , Técnicas In Vitro , Braquetes Ortodônticos
12.
J Sep Sci ; 38(5): 780-7, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25545460

RESUMO

A sensitive, reproducible, and rapid method was developed for the simultaneous determination of underivatized amino acids (aspartate, serine, glycine, alanine, methionine, leucine, tyrosine, and tryptophan) and neurotransmitters (glutamate and γ-aminobutyric acid) in plasma samples using hydrophilic interaction liquid chromatography coupled to triple quadrupole tandem mass spectrometry. The plasma concentrations of amino acids and neurotransmitters obtained from 35 schizophrenic patients in treatment with clozapine (27 patients) and olanzapine (eight patients) were compared with those obtained from 38 healthy volunteers to monitor the effectiveness of treatment. The chromatographic conditions separated ten target compounds within 3 min. This method presented linear ranges that varied from (lower limit of quantification: 9.7-13.3 nmol/mL) to (upper limit of quantification: 19.4-800 nmol/mL), intra- and interassay precision with coefficients of variation lower than 10%, and relative standard error values of the accuracy ranged from -2.1 to 9.9%. The proposed method appropriately determines amino acids and neurotransmitters in plasma from schizophrenic patients. Compared with the control group (healthy volunteers), the plasma levels of methionine in schizophrenic patients treated with olanzapine are statistically significantly higher. Moreover, schizophrenic patients treated with clozapine tend to have increased plasma levels of glutamate.


Assuntos
Aminoácidos/sangue , Cromatografia Líquida/métodos , Neurotransmissores/sangue , Esquizofrenia/sangue , Espectrometria de Massas em Tandem/métodos , Aminoácidos/química , Humanos , Interações Hidrofóbicas e Hidrofílicas , Limite de Detecção , Masculino , Neurotransmissores/química
13.
J Chromatogr A ; 1713: 464518, 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38000199

RESUMO

Organic-silica hybrid monolithic materials have attracted considerable attention as potential stationary phases in separation science. These materials combine the advantages of organic polymer and silica-based monoliths, including easy preparation, lower back pressure, high permeability, excellent mechanical strength, thermal stability, and tunable surface chemistry with high surface area and selectivity. The outstanding chromatographic efficiency as stationary phase of hybrid monolithic capillary columns for capillary liquid chromatography and capillary electrochromatography has been reported in many papers. Organic-silica hybrid monolithic materials have also been extensively used in the field of sample preparation. Owing to their surface functionalities, these porous sorbents offer unique selectivity for pre-concentration of different analytes in the most complex matrixes by fast dynamic transport. These sorbents not only improve the analytical method sensitivity, but also introduce novelties in terms of extraction devices and instrument coupling strategies. The current review covers the period spanning from 2017 to 2023 and describes the properties of organic-inorganic hybrid monolithic materials, the present status of this technology and summarizes recent developments in their use as innovative sorbents for microextraction sample preparation techniques (solid phase microextraction with pipette tip, offline in-tube SPME, in-tube SPME online with LC, and in-tube SPME directly coupled with mass spectrometry). Aspects such as the synthesis methods (sol-gel process, one-pot approach, and polyhedral oligomeric silsesquioxanes-based procedure), characterization techniques, and strategies to improve extraction efficiency in various applications in different areas (environmental, food, bioanalysis, and proteomics) are also discussed.


Assuntos
Eletrocromatografia Capilar , Dióxido de Silício , Dióxido de Silício/química , Cromatografia Líquida/métodos , Eletrocromatografia Capilar/métodos , Microextração em Fase Sólida/métodos , Polímeros
15.
Talanta ; 254: 124186, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36521326

RESUMO

Current research efforts at neurological diseases have focused on identifying novel biomarkers to aid in diagnosis, to provide accurate prognostic information, and to monitor disease progression. This study presents the direct coupling of fiber-in-tube solid-phase microextraction to tandem mass spectrometry as a reliable method to determine amyloid beta peptides (Aß38, Aß40, and Aß42) as biomarkers for Alzheimer's disease in cerebrospinal fluid (CSF) samples. To obtain the biocompatible fiber-in-tube SPME capillary, a PEEK tube segment was longitudinally packed with fine fibers [nitinol wires coated with a zwitterionic polymeric ionic liquid], to act as selective extraction medium. The fiber-in-tube SPME-MS/MS method integrated analyte extraction/enrichment and sample cleanup (exclusion of interferents) into one step. The method provided lower limits of quantification (LLOQ: 0.2 ng mL-1 for Aß38 and 0.1 ng mL-1 for Aß40 and Aß42), high precision (CV lower than 11.6%), and high accuracy (relative standard deviation lower than 15.1%). This method was successfully applied to determine Aß peptides in CSF samples obtained from AD patients (n = 8) and controls (healthy volunteers, n = 10). Results showed that Aß42 levels in the CSF samples obtained from AD patients were significantly lower compared to healthy controls (p < 0.05). On the basis of the ROC analysis results, the Aß42/Aß40 ratio (AUC = 0.950, p < 0.01; 95%) performed significantly better than Aß42 alone (AUC = 0.913, p < 0.01; 95%) in discriminating between AD patients and healthy controls and presented better diagnostic ability for AD. The novelties of this study are not only related to evaluating Aß peptides as AD biomarkers, but also to demonstrating direct online coupling of fiber-in-tube SPME with MS/MS as a quantitative high-throughput method for bioanalysis.


Assuntos
Doença de Alzheimer , Microextração em Fase Sólida , Espectrometria de Massas em Tandem , Humanos , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/líquido cefalorraquidiano , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Peptídeos beta-Amiloides/química , Biomarcadores , Fragmentos de Peptídeos , Microextração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos
16.
J Sep Sci ; 35(5-6): 734-41, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22318808

RESUMO

A sensitive, selective, and reproducible in-tube solid-phase microextraction and liquid chromatographic (in-tube SPME/LC-UV) method for determination of lidocaine and its metabolite monoethylglycinexylidide (MEGX) in human plasma has been developed, validated, and further applied to pharmacokinetic study in pregnant women with gestational diabetes mellitus (GDM) subjected to epidural anesthesia. Important factors in the optimization of in-tube SPME performance are discussed, including the draw/eject sample volume, draw/eject cycle number, draw/eject flow rate, sample pH, and influence of plasma proteins. The limits of quantification of the in-tube SPME/LC method were 50 ng/mL for both metabolite and lidocaine. The interday and intraday precision had coefficients of variation lower than 8%, and accuracy ranged from 95 to 117%. The response of the in-tube SPME/LC method for analytes was linear over a dynamic range from 50 to 5000 ng/mL, with correlation coefficients higher than 0.9976. The developed in-tube SPME/LC method was successfully used to analyze lidocaine and its metabolite in plasma samples from pregnant women with GDM subjected to epidural anesthesia for pharmacokinetic study.


Assuntos
Anestésicos Locais/farmacocinética , Cromatografia Líquida/métodos , Lidocaína/farmacocinética , Microextração em Fase Sólida/métodos , Adulto , Anestesia Epidural , Anestésicos Locais/sangue , Anestésicos Locais/isolamento & purificação , Anestésicos Locais/metabolismo , Automação , Cromatografia Líquida/instrumentação , Feminino , Humanos , Lidocaína/sangue , Lidocaína/isolamento & purificação , Lidocaína/metabolismo , Gravidez , Espectrofotometria Ultravioleta
17.
Anal Chim Acta ; 1193: 339394, 2022 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-35058015

RESUMO

Alzheimer disease (AD) is a neurodegenerative disorder characterized by extracellular accumulation of amyloid-ß peptide (Aß) in the brain interstitium. Human serum albumin (HSA) highly binds to Aß in blood plasma and is thought to inhibit plaque formation in peripheral tissue. Thus, the evaluation of albumin binding to Aß is an important key to understand the dynamics of these molecules in the biological system of patients with AD. In this work, a fiber-in-tube solid-phase microextraction (fiber-in-tube SPME) and ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed to estimate Aß fraction binding to HSA in cerebrospinal fluid (CSF) and plasma samples. Crosslinked zwitterionic polymeric ionic liquid (zwitterionic PIL)-coated nitinol wires were developed and packed into a polyether ether ketone (PEEK) capillary for a fiber-in-tube SPME and UHPLC-MS/MS method. Zwitterionic PIL sorbent was synthetized from 1-vinyl-3-(butanesulfonate)imidazolium ([VIm+C4SO3-]) and 1,12-di(3-vinylimidazolium)dodecane dibromide ([(VIm)2C12]2[Br]) monomers by in-situ thermally-initiated polymerization. Morphological characterization by scanning electron microscopy (SEM) and atomic force microscopy (AFM) revealed a decrease in the surface roughness of the nitinol wires from ∼17 nm to 1 nm after the in-situ polymerization. The zwitterionic PIL sorbent selectively preconcentrates Aß through a two-pronged interaction mechanism. The fiber-in-tube SPME and UHPLC-MS/MS method presented lower limits of quantification (LLOQ) of 0.4 ng mL-1 for Aß38 and 0.3 ng mL-1 for Aß40 and Aß42, a linear range from LLOQ values to 15 ng mL-1 with coefficients of determination higher than 0.99, precision with coefficient of variation (CV) values ranging from 2.1 to 7.3% and accuracy with relative standard deviation (RSD) values from -0.3 to 7.4. This method was successfully applied to evaluate the binding of HSA to Aß in cerebrospinal fluid (CSF) and plasma samples.


Assuntos
Peptídeos beta-Amiloides , Líquidos Iônicos , Ligas , Proteínas de Transporte , Cromatografia Líquida de Alta Pressão , Humanos , Microextração em Fase Sólida , Espectrometria de Massas em Tandem
18.
J Chromatogr A ; 1668: 462925, 2022 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-35263675

RESUMO

Miniaturized liquid chromatography (LC) has been recognized as one of the most important analytical methods in several research fields. Reduced analytical work-scale provides superior chromatographic resolution and decreases sample and organic solvent consumption. However, frequent clogging of tubing connections and use of small sample volumes are significant limitations when high throughput and sensitive analyses are required. Effective sample preparation could help to overcome these limitations. Online coupling of sample preparation techniques (such as column switching and in-tube solid-phase microextraction) with these miniaturized systems may result in more sensitive and reproducible analyses, improving analytical efficiency. This review describes the most common online miniaturized LC configurations, and the main applications of current online sample preparation techniques coupled to miniaturized LC systems in the bioanalytical, omics, and environmental areas. Relevant features, and challenges of these systems, and innovative sorbents, including restricted access materials, monoliths, and immunosorbents is also discussed.


Assuntos
Microextração em Fase Sólida , Manejo de Espécimes , Cromatografia Líquida/métodos , Imunoadsorventes , Microextração em Fase Sólida/métodos , Solventes
19.
Anal Chim Acta ; 1226: 340160, 2022 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-36068070

RESUMO

This manuscript describes the development of magnetic restricted-access carbon nanotubes (M-RACNTs) for use as SPME sorbent to determine cannabidiol (CBD) and delta-9-tetrahydrocannabinol (THC) in human plasma samples by UHPLC-MS/MS. The adsorptive phase was immobilized on an SPME device by electromagnetic interactions between the M-RACNTs and a cylindrical neodymium magnet (3-mm diameter x 8-mm height) attached to a stainless-steel rod (3-mm diameter x 40-mm height). The M-RACNTs were synthesized by incorporating Fe3O4 magnetic nanoparticles (MNPs) into commercial carbon nanotubes (CNTs); then the surface of the resulting sorbent was further coated with a layer of bovine serum albumin (BSA). Characterization techniques (SEM, FTIR, and Zeta potential) confirmed the presence of both MNPs and BSA layer dispersed through the structure of the CNTs. The M-RACNTs presented adequate sorption capacity, stable physical/chemical characteristics, and appropriate magnetic properties. Protein exclusion capacity (about 98.5%) was attributed to the chemical diffusion barrier created by the BSA network at the outer surface of the sorbent. The SPME parameters (sample pH, equilibrium time, and desorption conditions) were optimized by design of experiments (fraction factorial planning). The method (validated according to the FDA guidelines) presented adequate selectivity and linearity (coefficient of determination higher than 0.99) at concentrations ranging from the lower limit of quantification (LLOQ) (10 ng mL-1) to the upper limit of quantification (ULOQ) (300 ng mL-1) for both CBD and THC. Precision and accuracy varied from 4.47 to 19.84% (LLOQ) and -6.90 to 17.78% (LLOQ), respectively. Carry-over and matrix effect were not significant. The method was successfully applied to determine plasmatic CBD levels in healthy volunteers attending a single session of oral drug administration and THC levels in frequent cannabis smokers.


Assuntos
Canabinoides , Nanotubos de Carbono , Canabinoides/análise , Cromatografia Líquida de Alta Pressão/métodos , Dronabinol/análise , Humanos , Fenômenos Magnéticos , Nanotubos de Carbono/química , Microextração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos
20.
J Huntingtons Dis ; 11(1): 91-95, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35124656

RESUMO

Huntington's disease (HD) is an inherited neurodegenerative disease characterized by motor, cognitive and behavioral deficits. Some evidence suggests that the endocannabinoid system participates in the pathophysiology of HD. We conducted a cross-sectional study comparing plasma levels of anandamide and 2-arachidonoylglycerol in manifest HD gene-expansion carriers (HDGEC) and healthy controls, finding no difference in endocannabinoid levels between the groups. Correlations between endocannabinoid levels and clinical scales (Mini-Mental State Examination, Hospital Anxiety and Depression Scale, Unified Huntington Disease Rating Scale) were non-significant. We found a significant association between body mass index and anandamide levels in healthy controls but not in HDGEC.


Assuntos
Doença de Huntington , Doenças Neurodegenerativas , Estudos Transversais , Endocanabinoides , Heterozigoto , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA