Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Chem Soc Rev ; 47(13): 4697-4709, 2018 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-29770813

RESUMO

In this review, we have discussed the capabilities of nanomaterials for point-of-care (PoC) diagnostics and explained how these materials can help to strengthen, miniaturize and improve the quality of diagnostic devices. Since the optical, electrochemical and other physical properties of nanomaterials are dictated by their composition, size and shape, these factors are critical in the design and function of nanomaterial-based PoC diagnostics.


Assuntos
Nanomedicina/instrumentação , Nanoestruturas/química , Sistemas Automatizados de Assistência Junto ao Leito , Humanos
3.
Anal Chem ; 87(10): 5167-72, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25901535

RESUMO

In this article, a novel aptasensor for ochratoxin A (OTA) detection based on a screen-printed carbon electrode (SPCE) modified with polythionine (PTH) and iridium oxide nanoparticles (IrO2 NPs) is presented. The electrotransducer surface is modified with an electropolymerized film of PTH followed by the assembly of IrO2 NPs on which the aminated aptamer selective to OTA is exchanged with the citrate ions surrounding IrO2 NPs via electrostatic interactions with the same surface. Electrochemical impedance spectroscopy (EIS) in the presence of the [Fe(CN)6](-3/-4) redox probe is employed to characterize each step in the aptasensor assay and also for label-free detection of OTA in a range between 0.01 and 100 nM, obtaining one of the lowest limits of detection reported so far for label-free impedimetric detection of OTA (14 pM; 5.65 ng/kg). The reported system also exhibits a high reproducibility, a good performance with a white wine sample, and an excellent specificity against another toxin present in such sample.


Assuntos
Aptâmeros de Nucleotídeos/metabolismo , Técnicas Biossensoriais/métodos , Irídio/química , Nanopartículas , Ocratoxinas/análise , Técnicas Biossensoriais/instrumentação , Carbono/química , Impedância Elétrica , Eletroquímica , Eletrodos , Transporte de Elétrons , Limite de Detecção , Ocratoxinas/química , Ocratoxinas/metabolismo , Fenotiazinas/química , Polimerização
4.
Anal Chim Acta ; 1175: 338745, 2021 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-34330444

RESUMO

Metal ions homeostasis plays an important role in biological processes. The ability to detect the concentration of metal ions in biological fluids is often challenged by the obvious interference or competitive binding nature of other alkaline metals ions. Common analytical techniques employed for metal ions detection are electrochemical, fluorescence and colorimetric methods. However, most reported metal ions sensors are complicated, time-consuming and involve costly procedures with limited effectiveness. Herein, a nanobiosensor for detecting sodium and potassium ions using folic acid-functionalised reduced graphene oxide-modified RNase A gold nanoclusters (FA-rGO-RNase A/AuNCs) based on fluorescence "turn-off/turn-on" is presented. Firstly, a facile and optimised protocol for the fabrication of RNase A/AuNCs is developed. The activity of RNase A protein after the formation of RNase A/AuNCs is studied. RNase A/AuNCs is then loaded onto FA-rGO, in which FA-rGO is used as a potential carrier and fluorescence quencher for RNase A/AuNCs. Finally, a fluorescence "turn-on" sensing strategy is developed using the as-synthesised FA-rGO-RNase A/AuNCs to detect sodium and potassium ions. The developed nanobiosensor revealed an excellent sensing performance and meets the sensitivity required to detect both sodium and potassium ions. To the best of our knowledge, this is the first work done on determining the RNase A protein activity in RNase A/AuNCs and exploring the potential application of RNase A/AuNCs as a metal ion sensor. This work serves as a proof-of-concept for combining the potential of drug delivery, active targeting and therapy on cancer cells, as well as biosensing of metal ions into a single platform.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Ácido Fólico , Ouro , Grafite , Íons , Espectrometria de Fluorescência
5.
Sci Rep ; 11(1): 2375, 2021 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-33504892

RESUMO

Glutathione (GSH) is a useful biomarker in the development, diagnosis and treatment of cancer. However, most of the reported GSH biosensors are expensive, time-consuming and often require complex sample treatment, which limit its biological applications. Herein, a nanobiosensor for the detection of GSH using folic acid-functionalized reduced graphene oxide-modified BSA gold nanoclusters (FA-rGO-BSA/AuNCs) based on the fluorescence quenching interactions is presented. Firstly, a facile and optimized protocol for the fabrication of BSA/AuNCs is developed. Functionalization of rGO with folic acid is performed using EDC/NHS cross-linking reagents, and their interaction after loading with BSA/AuNCs is demonstrated. The formation of FA-rGO, BSA/AuNCs and FA-rGO-BSA/AuNCs are confirmed by the state-of-art characterization techniques. Finally, a fluorescence turn-off sensing strategy is developed using the as-synthesized FA-rGO-BSA/AuNCs for the detection of GSH. The nanobiosensor revealed an excellent sensing performance for the detection of GSH with high sensitivity and desirable selectivity over other potential interfering species. The fluorescence quenching is linearly proportional to the concentration of GSH between 0 and 1.75 µM, with a limit of detection of 0.1 µM under the physiological pH conditions (pH 7.4). Such a sensitive nanobiosensor paves the way to fabricate a "turn-on" or "turn-off" fluorescent sensor for important biomarkers in cancer cells, presenting potential nanotheranostic applications in biological detection and clinical diagnosis.

6.
Nat Protoc ; 15(12): 3788-3816, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33097926

RESUMO

Lateral-flow assays (LFAs) are quick, simple and cheap assays to analyze various samples at the point of care or in the field, making them one of the most widespread biosensors currently available. They have been successfully employed for the detection of a myriad of different targets (ranging from atoms up to whole cells) in all type of samples (including water, blood, foodstuff and environmental samples). Their operation relies on the capillary flow of the sample throughout a series of sequential pads, each with different functionalities aiming to generate a signal to indicate the absence/presence (and, in some cases, the concentration) of the analyte of interest. To have a user-friendly operation, their development requires the optimization of multiple, interconnected parameters that may overwhelm new developers. In this tutorial, we provide the readers with: (i) the basic knowledge to understand the principles governing an LFA and to take informed decisions during lateral flow strip design and fabrication, (ii) a roadmap for optimal LFA development independent of the specific application, (iii) a step-by-step example procedure for the assembly and operation of an LF strip for the detection of human IgG and (iv) an extensive troubleshooting section addressing the most frequent issues in designing, assembling and using LFAs. By changing only the receptors, the provided example procedure can easily be adapted for cost-efficient detection of a broad variety of targets.


Assuntos
Imunoensaio/métodos , Nanopartículas , Nanotecnologia/métodos , Animais , Desenho de Equipamento , Humanos , Imunoensaio/instrumentação , Nanotecnologia/instrumentação
7.
Anal Chim Acta ; 1046: 123-131, 2019 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-30482289

RESUMO

Tristeza is one of the destructive diseases of citrus causing by citrus tristeza virus (CTV). Historically, CTV has been associated with serious outbreaks of quick decline of citrus, therefore CTV monitoring is important aspect for avoiding such re-emerging epidemics, which would threat citrus production through the world. In this context, we have designed for the first time a label-free impedimetric biosensor for the detection of nucleic acid of CTV. The sensing platform based on a screen-printed carbon electrode (SPCE) was modified by electrodeposited gold nanoparticles (AuNPs), which allowed to efficiently immobilizing thiolated ssDNA probes as well to enhance the electrode conductivity. The growth of AuNPs was optimized and characterized using scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). We investigated the behavior of thiolated ssDNA probe layer and its hybridization with target DNA onto AuNP surfaces by EIS measurements in Fe(CN6)4-/Fe(CN6)3- red-ox system. The main sensor design aspects such as AuNPs size, probe DNA concentration and immobilization time together with DNA hybridization time were optimized so as to achieve the best performance. Impedance values of DNA hybridization increased with Citrus tristeza-related synthetic DNA concentration, showing a logarithmic relation in the range of 0.1-10 µM. The results also indicate that the biosensor was able to selectively detect CTV nucleic acids in the presence of other non-specific DNAs. Moreover, we have demonstrated the good performance of the system in a real plant sample matrix. In addition, the sensor reproducibility enhanced after the hybridization onto MCH/poly (AT) thiolated DNA probes which was confirmed by intra- and inter-day variability assays.


Assuntos
Técnicas Eletroquímicas , Ouro/química , Nanopartículas Metálicas/química , Vírus de Plantas/isolamento & purificação , Eletrodos , Tamanho da Partícula , Propriedades de Superfície
8.
Biosens Bioelectron ; 132: 132-135, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30870639

RESUMO

Lateral flow biosensors are paper-based devices that allow the detection of different types of analytes with quickness, robustness and selectivity, without leaving behind paper sensors benefits as low-cost, recyclability and sustainability. Nanomaterials have been widely reported in lateral flow biosensors, offering new sensing strategies based on optical or electrical detection techniques. Looking for other advantageous nanomaterials, we propose for the first time the use of iridium oxide (IV) nanoparticles in lateral flow assays for the detection of human immunoglobulin as a model protein. These nanoparticles can be easily prepared and conjugated with biomarkers. Their dark blue color gives a high contrast against the white background of the strips being in this way excellent labels.


Assuntos
Técnicas Biossensoriais/instrumentação , Imunoensaio/instrumentação , Imunoglobulinas/análise , Irídio/química , Nanopartículas/química , Fitas Reagentes/análise , Humanos , Limite de Detecção , Nanopartículas/ultraestrutura , Papel , Smartphone
9.
Biosens Bioelectron ; 127: 150-154, 2019 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-30597433

RESUMO

Polybrominated diphenyl ethers (PBDEs) are a type of flame retardants which are currently banned in EU and USA due their hazardousness for humans and mammals. However, these compounds were highly used during more than 30 years and still persist in the environment since they are resistant to degradation. Herein we present a biosensor for the detection of PBDEs using screen printed carbon electrodes (SPCEs) based on the electrochemical monitoring of water oxidation reaction (WOR) catalyzed by iridium oxide (IV) nanoparticles (IrO2 NPs). Our assay shows a limit of detection of 21.5 ppb of PBDE in distilled water. We believe that such an IrO2 NPs-based electrocatalytic sensing system can lead to a rapid, sensitive, low cost and miniaturizable device for the detection of PBDEs.


Assuntos
Técnicas Biossensoriais , Monitoramento Ambiental , Retardadores de Chama/isolamento & purificação , Éteres Difenil Halogenados/isolamento & purificação , Carbono/química , Catálise , Retardadores de Chama/efeitos adversos , Retardadores de Chama/toxicidade , Éteres Difenil Halogenados/química , Éteres Difenil Halogenados/toxicidade , Humanos , Irídio/química , Nanopartículas/química , Bifenil Polibromatos/química , Água/química
10.
Biosens Bioelectron ; 141: 111407, 2019 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-31207571

RESUMO

Lateral flow paper-based biosensors merge as powerful tools in point-of-care diagnostics since they are cheap, portable, robust, selective, fast and easy to use. However, the sensitivity of this type of biosensors is not always as high as required, often not permitting a clear quantification. To improve the colorimetric response of standard lateral flow strips (LFs), we have applied a new enhancement strategy that increases the sensitivity of LFs based on the use of cellulose nanofibers (CNF). CNF penetrate inside the pores of LFs nitrocellulose paper, compacting the pore size only in the test line, particularly near the surface of the strip. This modification retains the bioreceptors (antibodies) close to the surface of the strips, and thus further increasing the density of selectively attached gold nanoparticles (AuNPs) in the top part of the membrane, in the test line area, only when the sample is positive. This effect boosts in average a 36.6% the sensitivity of the LFs. The optical measurements of the LFs were carried out with a mobile phone camera whose imaging resolution was improved by attaching microscopic lens on the camera objective. The characterization of CNF into paper and their effect was analyzed using atomic force microscope (AFM) and scanning electron microscope (SEM) imaging techniques.


Assuntos
Técnicas Biossensoriais/instrumentação , Celulose/química , Ouro/química , Nanopartículas Metálicas/química , Nanofibras/química , Anticorpos Imobilizados/química , Colódio/química , Desenho de Equipamento , Humanos , Imunoglobulina G/análise , Fitas Reagentes/análise
11.
Sci Rep ; 8(1): 16157, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-30385866

RESUMO

The contamination in groundwater due to the presence of uranium is nowadays a subject of concern due to the severe health problems associated with renal failure, genotoxicity and cancer. The standard methods to detect uranium require time-consuming processes and expensive non-portable equipment, so these measurements are rarely performed in-field, which increases the time until water samples are analysed. Furthermore, the few portable methods available do not allow quantitative analysis and the detection limit is often not low enough to reach the recommendations for drinking water (30 ppb or 126 nM of uranium). For the first time, we propose a portable, fast, inexpensive and sensitive paper-based biosensor able to detect in situ U(VI) in water samples: U(VI) selective gold nanoparticle-based lateral flow strips. Antibody-coated gold nanoparticles are used as labels in the proposed lateral flow system because of their biocompatibility; in addition, these nanoparticles provide high sensitivity due to their intense plasmonic effect. The antibody used in the assay recognizes soluble U(VI) complexed to the chelator, 2,9-dicarboxyl-1,10-phenanthroline (DCP). Because of the small size of the U(VI)-DCP complex, this assay employs a competitive format that reaches a limit of detection of 36.38 nM, lower than the action level (126 nM) established by the World Health Organization and the U.S. Environmental Protection Agency for drinking waters.

12.
Biosens Bioelectron ; 92: 549-562, 2017 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-27836593

RESUMO

In this review we discuss recent developments on the use of mobile phones and similar devices for biosensing applications in which diagnostics and communications are coupled. Owing to the capabilities of mobile phones (their cameras, connectivity, portability, etc.) and to advances in biosensing, the coupling of these two technologies is enabling portable and user-friendly analytical devices. Any user can now perform quick, robust and easy (bio)assays anywhere and at any time. Among the most widely reported of such devices are paper-based platforms. Herein we provide an overview of a broad range of biosensing possibilities, from optical to electrochemical measurements; explore the various reported designs for adapters; and consider future opportunities for this technology in fields such as health diagnostics, safety & security, and environment monitoring.


Assuntos
Técnicas Biossensoriais/instrumentação , Telefone Celular/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Animais , Técnicas Biossensoriais/métodos , Colorimetria/instrumentação , Colorimetria/métodos , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Desenho de Equipamento , Humanos , Medições Luminescentes/instrumentação , Medições Luminescentes/métodos
13.
Biosens Bioelectron ; 73: 47-63, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-26043315

RESUMO

Lateral flow biosensors (LFBs) are paper-based devices which permit the performance of low-cost and fast diagnostics with good robustness, specificity, sensitivity and low limits of detection. The use of nanoparticles (NPs) as labels play an important role in the design and fabrication of a lateral flow strip (LFS). The choice of NPs and the corresponding detection method directly affect the performance of these devices. This review discusses aspects related to the application of different nanomaterials (e.g. gold nanoparticles, carbon nanotubes, quantum dots, up-converting phosphor technologies, and latex beads, between others) in LFBs. Moreover, different detection methods (colorimetric, fluorescent, electrochemical, magnetic, etc.) and signal enhancement strategies (affording secondary reactions or modifying the architecture of the LFS) as well as the use of devices such as smartphones to mediate the response of LFSs will be analyzed.


Assuntos
Técnicas Biossensoriais/instrumentação , Nanopartículas , Animais , Carbono , Corantes , Técnicas Eletroquímicas/instrumentação , Corantes Fluorescentes , Ouro , Humanos , Lipossomos , Nanopartículas de Magnetita , Nanopartículas Metálicas , Pontos Quânticos
14.
J Mater Chem B ; 3(26): 5166-5171, 2015 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-32262591

RESUMO

An impedimetric label-free genosensor for high sensitive DNA detection is developed. This system is based on a screen-printed carbon electrode modified with the thionine layer and iridium oxide nanoparticles (IrO2 NP). An aminated oligonucleotide probe is immobilized on the IrO2 NP/polythionine modified electrode and ethanolamine was used as a blocking agent. Different diluted PCR amplified DNA samples have been detected. The selectivity and reproducibility of this system are studied and the system was highly reproducible with RSD ≈ 15% and sensitive enough while using 2% of ethanolamine during the blocking step employed for genosensor preparation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA