Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Eur Radiol ; 2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38244046

RESUMO

OBJECTIVE: To determine the inter-reader reliability and diagnostic performance of classification and severity scales of Neuropathy Score Reporting And Data System (NS-RADS) among readers of differing experience levels after limited teaching of the scoring system. METHODS: This is a multi-institutional, cross-sectional, retrospective study of MRI cases of proven peripheral neuropathy (PN) conditions. Thirty-two radiology readers with varying experience levels were recruited from different institutions. Each reader attended and received a structured presentation that described the NS-RADS classification system containing examples and reviewed published articles on this subject. The readers were then asked to perform NS-RADS scoring with recording of category, subcategory, and most likely diagnosis. Inter-reader agreements were evaluated by Conger's kappa and diagnostic accuracy was calculated for each reader as percent correct diagnosis. A linear mixed model was used to estimate and compare accuracy between trainees and attendings. RESULTS: Across all readers, agreement was good for NS-RADS category and moderate for subcategory. Inter-reader agreement of trainees was comparable to attendings (0.65 vs 0.65). Reader accuracy for attendings was 75% (95% CI 73%, 77%), slightly higher than for trainees (71% (69%, 72%), p = 0.0006) for nerves and comparable for muscles (attendings, 87.5% (95% CI 86.1-88.8%) and trainees, 86.6% (95% CI 85.2-87.9%), p = 0.4). NS-RADS accuracy was also higher than average accuracy for the most plausible diagnosis for attending radiologists at 67% (95% CI 63%, 71%) and for trainees at 65% (95% CI 60%, 69%) (p = 0.036). CONCLUSION: Non-expert radiologists interpreted PN conditions with good accuracy and moderate-to-good inter-reader reliability using the NS-RADS scoring system. CLINICAL RELEVANCE STATEMENT: The Neuropathy Score Reporting And Data System (NS-RADS) is an accurate and reliable MRI-based image scoring system for practical use for the diagnosis and grading of severity of peripheral neuromuscular disorders by both experienced and general radiologists. KEY POINTS: • The Neuropathy Score Reporting And Data System (NS-RADS) can be used effectively by non-expert radiologists to categorize peripheral neuropathy. • Across 32 different experience-level readers, the agreement was good for NS-RADS category and moderate for NS-RADS subcategory. • NS-RADS accuracy was higher than the average accuracy for the most plausible diagnosis for both attending radiologists and trainees (at 75%, 71% and 65%, 65%, respectively).

2.
Scand J Med Sci Sports ; 34(3): e14590, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38483076

RESUMO

Intense physical exercise is known to increase cardiac biomarkers; however, it is unclear, whether this phenomenon is physiological, or if it indicates myocardial tissue injury. The aim of our study was to investigate the effects of seven consecutive days of excessive endurance exercise on continuous assessment of cardiac biomarkers, function, and tissue injury. During a 7-day trail-running competition (Transalpine Run, distance 267.4 km, altitude ascent/descent 15556/14450 m), daily blood samples were obtained for cardiac biomarkers (hs-TnT, NT-proBNP, and suppression of tumorigenicity-2 protein (ST2)) at baseline, after each stage and 24-48 h post-race. In addition, echocardiography was performed every second day, cardiac magnetic resonance imaging (CMR) before (n = 7) and after (n = 16) the race. Twelve (eight males) out of 17 healthy athletes finished all seven stages (average total finish time: 43 ± 8 h). Only NT-proBNP increased significantly (3.6-fold, p = 0.009) during the first stage and continued to increase during the race. Hs-TnT revealed an incremental trend during the first day (2.7-fold increase, p = 0.098) and remained within the pathological range throughout the race. ST2 levels did not change during the race. All cardiac biomarkers completely returned to physiological levels post-race. NT-proBNP kinetics correlated significantly with mild transient reductions in right ventricular function (assessed by TAPSE, tricuspid annular plane systolic function; r = -0.716; p = 0.014). No significant echocardiographic changes in LV dimensions, LV function, or relevant alterations in CMR were observed post-race. In summary, this study shows that prolonged, repetitive, high-volume exercise induced a transient, significant increase in NT-proBNP associated with right ventricular dysfunction without corresponding left ventricular functional or structural impairment.


Assuntos
Proteína 1 Semelhante a Receptor de Interleucina-1 , Corrida , Masculino , Humanos , Proteína 1 Semelhante a Receptor de Interleucina-1/metabolismo , Biomarcadores , Miocárdio/metabolismo , Coração/diagnóstico por imagem , Coração/fisiologia , Corrida/fisiologia , Peptídeo Natriurético Encefálico , Fragmentos de Peptídeos , Troponina T
3.
Eur Radiol ; 32(7): 4738-4748, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35258673

RESUMO

OBJECTIVES: To evaluate the performance and reproducibility of MR imaging features in the diagnosis of joint invasion (JI) by malignant bone tumors. METHODS: MR images of patients with and without JI (n = 24 each), who underwent surgical resection at our institution, were read by three radiologists. Direct (intrasynovial tumor tissue (ITT), intraarticular destruction of cartilage/bone, invasion of capsular/ligamentous insertions) and indirect (tumor size, signal alterations of epiphyseal/transarticular bone (bone marrow replacement/edema-like), synovial contrast enhancement, joint effusion) signs of JI were assessed. Odds ratios, sensitivity, specificity, PPV, NPV, and reproducibilities (Cohen's and Fleiss' κ) were calculated for each feature. Moreover, the diagnostic performance of combinations of direct features was assessed. RESULTS: Forty-eight patients (28.7 ± 21.4 years, 26 men) were evaluated. All readers reliably assessed the presence of JI (sensitivity = 92-100 %; specificity = 88-100%, respectively). Best predictors for JI were direct visualization of ITT (OR = 186-229, p < 0.001) and destruction of intraarticular bone (69-324, p < 0.001). Direct visualization of ITT was also highly reliable in assessing JI (sensitivity, specificity, PPV, NPV = 92-100 %), with excellent reproducibility (κ = 0.83). Epiphyseal bone marrow replacement and synovial contrast enhancement were the most sensitive indirect signs, but lacked specificity (29-54%). By combining direct signs with high specificity, sensitivity was increased (96 %) and specificity (100 %) was maintained. CONCLUSION: JI by malignant bone tumors can reliably be assessed on preoperative MR images with high sensitivity, specificity, and reproducibility. Particularly direct visualization of ITT, destruction of intraarticular bone, and a combination of highly specific direct signs were valuable, while indirect signs were less predictive and specific. KEY POINTS: • Direct visualization of intrasynovial tumor was the single most sensitive and specific (92-100%) MR imaging sign of joint invasion. • Indirect signs of joint invasion, such as joint effusion or synovial enhancement, were less sensitive and specific compared to direct signs. • A combination of the most specific direct signs of joint invasion showed best results with perfect specificity and PPV (both 100%) and excellent sensitivity and NPV (both 96 %).


Assuntos
Neoplasias Ósseas , Neoplasias Ósseas/diagnóstico , Humanos , Ligamentos Articulares/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Knee Surg Sports Traumatol Arthrosc ; 29(6): 1960-1967, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32965547

RESUMO

PURPOSE: Ultrasound (US) examination of the medial joint space of the knee has played a subordinate diagnostic role up till now. The purpose of the present study was to describe mean values of medial joint width and to investigate the impact of gender, age, and body mass index (BMI) on medial joint laxity in healthy knees using modern, dynamic US in a standardized fashion in unloaded and standardized loaded conditions. METHODS: A total of 65 subjects with 79 healthy knees were enrolled in this study. All volunteers underwent clinical examination of the knee. The medial knee joint width was determined using US in a supine position at 0° and 30° of knee flexion in unloaded and standardized loaded (= 15 Dekanewton, daN) conditions using a specific device. Mean values were described and correlations between medial knee joint width and gender, age, and BMI were assessed. RESULTS: Thirty-two females and 33 males were enrolled in this study. The mean medial joint width in 0° unloaded was 5.7 ± 1.2 mm and 7.4 ± 1.4 mm loaded. In 30° of knee flexion, the mean medial joint width was 6.1 ± 1.1 mm unloaded and 7.8 ± 1.2 mm loaded. The average change between unloaded and loaded conditions in 0° was 1.7 ± 1.0 mm and in 30° 1.7 ± 0.9 mm. A significant difference between genders was evident for medial joint width in 0° and 30° of flexion in unloaded and loaded conditions (p < 0.05). With rising age, a significant increased change of medial joint space width between unloaded and loaded conditions could be demonstrated in 0° (p = 0.032). No significant correlation between BMI and medial joint width in US could be found. CONCLUSION: Mean values of medial joint width in unloaded and standardized loaded conditions using a fixation device could be demonstrated. Based on the results of this study, medial knee joint width in US is gender- and age-related in healthy knees. These present data may be useful for evaluating patients with acute or chronic pathologies to the medial side of the knee. LEVEL OF EVIDENCE: III.


Assuntos
Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/fisiopatologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiologia , Ligamentos/diagnóstico por imagem , Ligamentos/fisiologia , Adulto , Fatores Etários , Fenômenos Biomecânicos , Índice de Massa Corporal , Feminino , Humanos , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Ligamentos/cirurgia , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Fatores Sexuais , Ultrassonografia
5.
Eur Radiol ; 29(7): 3424-3430, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31062134

RESUMO

OBJECTIVE: To evaluate contrast-enhanced T1-weighted magnetic resonance (MR) images in histologically proven fibrous dysplasia (FD) for the prevalence of "milk cloud appearance" and its association with ground-glass appearance (GGA) on radiography or computed tomography (CT). METHODS: For this retrospective cohort study, 37 patients with histologically proven FD imaged preoperatively with contrast-enhanced MR imaging and radiography or CT were identified at our institution. Three radiologists independently evaluated MR images for the presence of milk cloud appearance on T1-weighted contrast-enhanced images, sites of skeletal involvement, type of bone involved, uni- vs. multifocality, mono- vs. polyostotic disease, maximum diameter, proportion of bone involved, expansile remodeling, and T2 homogeneity. The presence or absence of GGA on radiography or CT was determined in consensus. Inter-reader agreement was evaluated for milk cloud appearance using Cohen's kappa, and associations between milk cloud appearance and other imaging parameters were tested using Spearman's rho. RESULTS: Among the 37 histologically proven FD lesions, GGA was identified in 70% of the lesions, while milk cloud appearance was found in 82% of the lesions. Inter-reader agreement for milk cloud appearance on MR imaging was good to excellent (κ 0.65, 0.82, and 0.8). A significant correlation was found between milk cloud appearance and GGA (ρ = 0.31, p < 0.001). CONCLUSION: Milk cloud appearance is a characteristic sign of FD on contrast-enhanced T1-weighted MR images. Recognition of this feature may be helpful when radiographs are equivocal or unremarkable or when MR imaging is performed as the primary imaging modality in cases of FD. KEY POINTS: • Fibrous dysplasia displays a characteristic feature on contrast-enhanced T1-weighted MR imaging: milk cloud appearance. • Milk cloud appearance correlates well with the radiographic or CT finding of ground-glass appearance. • Recognition of milk cloud appearance on contrast-enhanced MR imaging may be helpful when radiographs are equivocal or unremarkable or when MR imaging is performed as the primary imaging modality in cases of fibrous dysplasia.


Assuntos
Osso e Ossos/patologia , Meios de Contraste/farmacologia , Displasia Fibrosa Óssea/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
6.
BMC Med Imaging ; 19(1): 57, 2019 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-31340756

RESUMO

BACKGROUND: In this study we sought to retrospectively evaluate whether a very brief cardiac magnetic resonance imaging (CMR) protocol sufficiently distinguishes patients with relevant myocardial changes with need for further examination from healthy subjects. METHODS: Patients with clinical indication for CMR (n = 160) were included in the study. Patients were categorized into two groups depending on presence of left ventricular (LV) dysfunction. ROC-analysis was done for results of T1-, T2- mapping and extracellular volume evaluation in patients without LV dysfunction. Binary endpoint was correctly depicted pathology of the conventional qualitative CMR techniques and report. RESULTS: In the patient cohort without LV dysfunction (49%), AUC for T1 mapping was 82% (p < 0.001), 60% for T2 mapping (p = 0.1) and 79% for ECV (p < 0.001). T1 mapping was significantly superior to T2 mapping to rule out left ventricular pathology (p = 0.012). Sensitivity for the combined use of T1 mapping and sBTFE cine imaging was 98%; the negative predictive value was 90%. In 49 patients (30%) full protocol CMR did not provide any additional information; T1 mapping correctly detected 57% of the subjects from this group who would not benefit from additional CMR. CONCLUSION: A shortened CMR protocol comprising T1 mapping and LV-function analysis seems suitable to rule out myocardial alterations. Every third patient of the study population did not benefit from full contrast enhanced CMR. The shortened protocol correctly identified every fifth patient who would not benefit but no relevant pathologic findings with the obligation for treatment were missed.


Assuntos
Imagem Cinética por Ressonância Magnética/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Disfunção Ventricular Esquerda/patologia , Função Ventricular Esquerda
7.
Eur Radiol ; 28(12): 4925-4931, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29808428

RESUMO

PURPOSE: The aim of this study was to evaluate the advantages of dual-layer spectral CT (DLSCT) in detection and staging of head and neck cancer (HNC) as well as the imaging of tumour margins and infiltration depth compared to conventional contrast enhanced CT (CECT). MATERIALS AND METHODS: Thirty-nine patients with a proven diagnosis of HNC were examined with a DLSCT scanner and retrospectively analysed. An age-matched healthy control group of the same size was used. Images were acquired in the venous phase. Virtual monoenergetic 40keV-equivalent (MonoE40) images were compared to CECT-images. Diagnostic confidence for tumour identification and margin detection was rated independently by four experienced observers. The steepness of the Hounsfield unit (HU)-increase at the tumour margin was analysed. External carotid artery branch image reconstructions were performed and their contrast compared to conventional arterial phase imaging. Means were compared using a Student's t-test. ANOVA was used for multiple comparisons. RESULTS: MonoE40 images were superior to CECT-images in tumour detection and margin delineation. MonoE40 showed significantly higher attenuation differences between tumour and healthy tissue compared to CECT-images (p < 0.001). The HU-increase at the boundary of the tumour was significantly steeper in MonoE40 images compared to CECT-images (p < 0.001). Iodine uptake in the tumour was significantly higher compared to healthy tissue (p < 0.001). MonoE40 compared to conventional images allowed visualisation of external carotid artery branches from the venous phase in a higher number of cases (87% vs. 67%). CONCLUSION: DLSCT enables improved detection of primary and recurrent head and neck cancer and quantification of tumour iodine uptake. Improved contrast of MonoE40 compared to conventional reconstructions enables higher diagnostic confidence concerning tumour margin detection and vessel identification. KEY POINTS: • Sensitivity concerning tumour detection are higher using dual-layer spectral-CT than conventional CT. • Lesion to background contrast in DLSCT is significantly higher than in CECT. • DLSCT provides sufficient contrast for evaluation of external carotid artery branches.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Análise de Variância , Artérias Carótidas/diagnóstico por imagem , Estudos de Casos e Controles , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Estadiamento de Neoplasias/métodos , Estudos Retrospectivos , Sensibilidade e Especificidade
8.
Acta Radiol ; 59(10): 1225-1231, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29320863

RESUMO

Background The explosive growth of computer tomography (CT) has led to a growing public health concern about patient and population radiation dose. A recently introduced technique for dose reduction, which can be combined with tube-current modulation, over-beam reduction, and organ-specific dose reduction, is iterative reconstruction (IR). Purpose To evaluate the quality, at different radiation dose levels, of three reconstruction algorithms for diagnostics of patients with proven liver metastases under tumor follow-up. Material and Methods A total of 40 thorax-abdomen-pelvis CT examinations acquired from 20 patients in a tumor follow-up were included. All patients were imaged using the standard-dose and a specific low-dose CT protocol. Reconstructed slices were generated by using three different reconstruction algorithms: a classical filtered back projection (FBP); a first-generation iterative noise-reduction algorithm (iDose4); and a next generation model-based IR algorithm (IMR). Results The overall detection of liver lesions tended to be higher with the IMR algorithm than with FBP or iDose4. The IMR dataset at standard dose yielded the highest overall detectability, while the low-dose FBP dataset showed the lowest detectability. For the low-dose protocols, a significantly improved detectability of the liver lesion can be reported compared to FBP or iDose4 ( P = 0.01). The radiation dose decreased by an approximate factor of 5 between the standard-dose and the low-dose protocol. Conclusion The latest generation of IR algorithms significantly improved the diagnostic image quality and provided virtually noise-free images for ultra-low-dose CT imaging.


Assuntos
Algoritmos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Metástase Neoplásica/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estudos Prospectivos
9.
Knee Surg Sports Traumatol Arthrosc ; 26(8): 2282-2288, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29511818

RESUMO

PURPOSE: Meniscus extrusion has always been described as an indirect sign of meniscus pathology and is associated with a loss of function of the affected meniscus. The current cut-off value of 3 mm displacement is indicated as abnormal and has been determined on magnetic resonance images (MRI) and ultrasound (US). However, it has to be considered that there is no description of the physiological meniscus extrusion in healthy knees depending on age or different weight-bearing conditions. It was hypothesized that in healthy knees there is a physiological age and BMI dependent meniscal extrusion, and meniscus extrusion depends on different loading conditions. METHODS: Healthy volunteers with non-symptomatic knee, and no history of knee injuries or operations were included in this prospective cross-sectional study. Exclusion criteria were age < 18years, subjective or objective instability, malalignment and positive medial meniscus test. Secondary exclusion criteria were osteoarthritis ICRS grade 3-4 or signs of meniscus tear on MRI. Every patient underwent standard knee examination following measurement of medial meniscus extrusion (MME) using US. In US extrusion was determined in supine position (unloaded) and in standing position with full weight-bearing and 20° of flexion (loaded). MRI was performed in a neutral knee position to compare ultrasound measurements with the current gold standard. Based on the power calculation of preliminary results a minimum of 70 volunteers was needed. RESULTS: 75 patients were enrolled to this study. The mean US MME was 1.1 mm ± 0.5 mm in supine position and 1.9 mm ± 0.9 mm under full weight-bearing. The mean US Δ-extrusion was 0.8 mm ± 0.6 mm. With rising age, a significant increased MME in US and MRI could be demonstrated (p < 0.001). Furthermore, elevated BMI was significantly correlated to increased US MME under full weight-bearing (p = 0.002) and to US Δ-extrusion (p = 0.003). CONCLUSION: Based on the results of this study, medial meniscus extrusion is an age-depending phenomenon in healthy knees and depends on various load-bearing conditions. Ultrasound examination of the MME might be favorable compared to MRI due to the ability of dynamic evaluation. As a consequence, the current cut-off value of 3 mm for meniscus pathologies should be reconsidered. LEVEL OF EVIDENCE: III.


Assuntos
Envelhecimento/fisiologia , Índice de Massa Corporal , Meniscos Tibiais/fisiologia , Adulto , Idoso , Estudos Transversais , Feminino , Voluntários Saudáveis , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Meniscos Tibiais/diagnóstico por imagem , Pessoa de Meia-Idade , Postura , Estudos Prospectivos , Ultrassonografia/métodos , Suporte de Carga , Adulto Jovem
10.
Eur Radiol ; 26(9): 2871-80, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26560724

RESUMO

OBJECTIVE: To compare prospectively image quality and diagnostic confidence of flow-sensitive 3D turbo spin echo (TSE)-based non-contrast-enhanced MR angiography (NE-MRA) at 3.0 T using dual-source radiofrequency (RF) transmission with contrast-enhanced MRA (CE-MRA) in patients with peripheral arterial occlusive disease (PAOD). METHODS: After consent was obtained, 35 patients (mean age 69.1 ± 10.6 years) with PAOD stage II-IV underwent NE-MRA followed by CE-MRA. Signal-to-noise ratio and contrast-to-noise ratio were calculated. Subjective image quality was independently assessed by two radiologists and stenosis scoring was performed in 875 arterial segments. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for stenosis classification were calculated using CE-MRA as a reference method. Diagnostic agreement with CE-MRA was evaluated with Cohen's kappa statistics. RESULTS: NE-MRA provided high objective and subjective image quality at all levels of the arterial tree. Sensitivity and specificity for the detection of relevant stenosis was 91 % and 89 %, respectively; the NPV was 96 % and the PPV 78 %. There was good concordance between CE-MRA and NE-MRA in stenosis scoring. CONCLUSIONS: 3D electrocardiography (ECG)-gated TSE NE-MRA with patient-adaptive dual-source RF transmission at 3.0 T is a promising alternative for PAOD patients with contraindications for gadolinium-based contrast agents. It offers high sensitivity and NPV values in the detection of clinically relevant arterial stenosis. KEY POINTS: • Flow-sensitive TSE NE-MRA is a promising technique for PAOD evaluation. • Diagnostic accuracy is comparable to contrast-enhanced MRA. • NE-MRA eliminates the risk of NSF in patients with renal insufficiency. • Costs arising from the use of contrast agents can be avoided.


Assuntos
Meios de Contraste , Eletrocardiografia/métodos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Doença Arterial Periférica/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Extremidade Inferior/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ondas de Rádio , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
11.
Int J Cardiovasc Imaging ; 38(11): 2491-2500, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36434331

RESUMO

This study aimed to prospectively evaluate delayed enhancement imaging by spectral computed tomography using soluble iodine containing contrast media to improve the in vivo characterization of coronary plaque types based on the quantification of delayed iodine enhancement. Patients with known or suspected coronary artery disease (CAD) underwent spectral coronary CT-angiography (SCCTA). Absolute delayed iodine enhancement in all visible coronary plaques was assessed. Patients with significant CAD (> 50% stenosis) further underwent invasive coronary angiography (ICA) including optical coherence tomography (OCT). We identified 50 non-calcified coronary plaques in 72 patients undergoing SCCTA. 17 patients with significant CAD underwent further ICA including OCT imaging. In those, we were able to match 35 plaques by both SCCTA and OCT. Based on OCT imaging, 22/35 matched plaques (63%) were characterized as high-risk coronary plaques (thin-cap fibroatheroma n = 2, fibroatheroma n = 20), whereas 13/35 (37%) were characterized as low-risk plaques (fibrocalcific lesion n = 3, fibrous plaques n = 9, and early-onset fibroatheroma n = 1). All plaques showed similar HU's and could not be classified into high-risk or low-risk plaques by conventional CT measures. Minimal delayed iodine enhancement within plaques as quantified by SCCTA demonstrated significantly lower values in high-risk as compared to low-risk coronary plaques (1.0 ± 1.5 mg/ml vs. 2.2 ± 1.1 mg/ml, p = 0.021) which allowed estimation of high-risk plaques with high sensitivity and moderate specificity (77% and 56%). Measurement of delayed enhancement iodine uptake within stable coronary artery plaques using dual-layer SCCTA might contribute to a more precise estimation of plaque vulnerability surpassing conventional CT techniques.


Assuntos
Doença da Artéria Coronariana , Iodo , Placa Aterosclerótica , Humanos , Placa Aterosclerótica/patologia , Tomografia de Coerência Óptica/métodos , Angiografia por Tomografia Computadorizada , Valor Preditivo dos Testes , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia
13.
Eur J Radiol ; 115: 53-58, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31084759

RESUMO

OBJECTIVES: To compare the image quality between compressed sensing (CS) 3D-magnetic resonance cholangiopancreatography (MRCP) using respiratory-triggered (RT) and breath-hold (BH) acquisitions and 2D single-shot breath-hold (SSBH) MRCP at 3 T MRI. METHODS: 53 datasets were retrospectively assessed. 3D-MRCP with CS (RT-CS10, BH-CS24) and 2D-SSBH MRCP were acquired. Overall image quality, blurring/motion artifacts and discernibility of the pancreaticobiliary tree (PBT) structures were scored on a 4-point scale by 2 radiologists. The contrast ratio between the common bile duct and its adjacent tissue was measured by region-of-interest (ROI) analysis. Signal intensity increase at the boundaries of the ducts was quantified by line profiles to objectively characterize blurring and motion artifacts. RESULTS: Total scan duration was 17 s for BH-CS24, 1m12 s for 2D-SSBH and 3m48 s for RT-CS10. Images acquired with CS were consistently rated superior in terms of image quality, background suppression, blurring and discernibility of PBT structures compared to 2D-SSBH images. RT-CS10 was superior to BH-CS24 for all ratings except for blurring. Objective analysis yielded the highest contrast ratio for RT-CS10 (0.91 ± 0.04) followed by BH-C24 (0.88 ± 0.05) and 2D-SSBH (0.85 ± 0.06); one-way ANOVA P < 0.0001. The line-profile slope through the CBD was significantly higher in BH-CS24 (37.91 ± 6.38% of maximum intensity/mm) compared to RT-CS10 (29.46 ± 8.17% of maximum intensity/mm) and on par with 2D-SSBH (35.8 ± 12.30% of maximum intensity/mm); one-way-ANOVA P = 0.017. CONCLUSION: CS allows acquisition of volumetric image data with improved image quality compared to SSBH. CS24 yields substantial gains in acquisition speed while robust towards artifacts, enabling diagnostic image quality with a single breath-hold acquisition.


Assuntos
Doenças dos Ductos Biliares/patologia , Pancreatopatias/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Artefatos , Suspensão da Respiração , Colangiopancreatografia por Ressonância Magnética/métodos , Ducto Colédoco/patologia , Feminino , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Estudos Retrospectivos , Adulto Jovem
14.
Rofo ; 190(11): 1025-1035, 2018 Nov.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-30103237

RESUMO

BACKGROUND: Blood flow through the cavities of the heart and great vessels is pulsatile and is subject to time and multidirectional variations. To date, the recording of blood flow in multiple directions and phases has been limited. 4D-flow MRI offers advantages for the recording, visualization and analysis of blood flow. METHOD: The status quo of the method was summarized through analysis with the PubMed database using the keywords "4D-flow MRI, phase-contrast magnetic resonance imaging, MR flow imaging/visualization, MR flow quantification, 3 D cine (time-resolved) phase-contrast CMR, three-directional velocity-encoding MRI". RESULTS/CONCLUSION: This review summarizes the current status of the technical development of 4D-flow MRI, discusses its advantages and disadvantages and describes clinical applications. Finally, the most important principles and parameters are explained to give the reader relevant information about clinical indications, postprocessing methods and limitations of the method. KEY POINTS: · 4D-Fluss-MRT. · 3-dimensionale zeitaufgelöste Phasenkontrast-MRT. · Flussanalyse-MRT (Wall-Shear-Stress/Druckgradienten-Messung/Vortex-Fluss/turbulente kinetische Energie/Flussgeschwindigkeit/Flussrate). CITATION FORMAT: · Sträter A, Huber A, Rudolph J et al. 4D-Flow MRI: Technique and Applications. Fortschr Röntgenstr 2018; 190: 1025 - 1035.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Humanos , Masculino , Próstata/diagnóstico por imagem , Sensibilidade e Especificidade
15.
PLoS One ; 13(12): e0208588, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30521612

RESUMO

PURPOSE: Modern non-invasive evaluation of Coronary Artery Disease (CAD) requires non-contrast low dose Computed Tomography (CT) imaging for determination of Calcium Scoring (CACS) and contrast-enhanced imaging for evaluation of vascular stenosis. Several methods for calculation of CACS from contrast-enhanced images have been proposed before. The main principle for that is generation of virtual non-contrast images by iodine subtraction from a contrast-enhanced spectral CT dataset. However, those techniques have some limitations: Dual-Source CT imaging can lead to increased radiation exposure, and switching of the tube voltage (rapid kVp switching) can be associated with slower rotation speed of the gantry and is thus prone to motion artefacts that are especially critical in cardiac imaging. Both techniques cannot simultaneously acquire spectral data. A novel technique to overcome these difficulties is spectral imaging with a dual-layer detector. After absorption of the lower energetic photons in the first layer, the second layer detects a hardened spectrum of the emitted radiation resulting in registration of two different energy spectra at the same time. The objective of the present investigation was to evaluate the accuracy of virtual non-contrast CACS computed from spectral data in comparison to standard non-contrast imaging. METHODS: We consecutively investigated 20 patients referred to Coronary Computed Tomography Angiography (CCTA) with suspicion of CAD using a Dual-Layer spectral CT system (IQon; Philips Healthcare, The Netherlands). CACS was calculated from both, real- and virtual non-contrast images by certified software for medical use. Correlation analyses for real- and virtual non-contrast images and agreement evaluation with Bland-Altman-Plots were performed. RESULTS: Mean patient age was 57.7 ± 14 years (n = 20). 13 patients (65%) were male. Inter-quartile-range of clinical CACS was 0-448, the mean was 334. Correlation of CACS from real- and virtual non-contrast images was very high (0.94); p < 0.0001. The slope was 2.3 indicating that values from virtual non-contrast images are approximately half of the results obtained from real non-contrast data. Visual analysis of Bland-Altman-Plot shows good accordance of both methods when results from virtual non-contrast data are multiplied by the slope of the logistic regression model (2.3). The acquired power of this results is 0.99. CONCLUSION: Determination of Calcium Score from contrast enhanced CCTA using spectral imaging with a dual-layer detector is feasible and shows good agreement with the conventional technique when a proportionality factor is applied. The observed difference between both methods is due to an underestimation of plaque volume, and-to an even greater extend -an underestimation of plaque density with the virtual non-contrast approach. Our data suggest that radiation exposure can be reduced through omitting additional native scans for patients referred to CCTA when using a dual-layer spectral system without the usual limitations of dual energy analysis.


Assuntos
Cálcio/análise , Angiografia por Tomografia Computadorizada/métodos , Adulto , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Razão Sinal-Ruído
16.
J Thorac Imaging ; 33(4): 246-253, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29863589

RESUMO

PURPOSE: Computed tomography angiography (CTA) requires IV application of iodine-based contrast agents. There are several medical conditions in which application is not advisable or even feasible, especially for elective examinations. Novel techniques such as monoenergetic reconstructions from dual-energy computed tomographic (CT) data have been shown to increase radiation attenuation of gadolinium (Gd)-based contrast agents in a phantom model. Therefore, the purpose of the present investigation was to evaluate the technical feasibility and image quality of clinical spectral CTA with a Gd-based contrast agent. MATERIALS AND METHODS: Eleven consecutive patients with common indications for thoracic CTA and contraindications for iodine-based contrast agents were examined using clinical routine doses (0.2 mmol/kg) of Gd-based contrast agent with spectral CT. Monoenergetic reconstructions of the spectral data set were computed. RESULTS: We performed 11 Gd-enhanced CTAs: 9 aortic angiographies, 1 coronary angiography, and 1 angiography of the pulmonary arteries. Image quality of the monoenergetic reconstructions with 40 keV (monoE40) was considered diagnostic by 2 experienced radiologists in each patient; the conventional CT reconstructions did not reach diagnostic image quality. MonoE40 reconstruction resulted in a substantial, ∼2-fold increase of intravascular Gd attenuation compared with the conventional images (P<0.0001). No relevant change of attenuation was observed for the myocardium or the skeletal muscle. CONCLUSIONS: With spectral CT and reconstruction of monoenergetic images with extrapolated 40 keV, Gd-based contrast agent thoracic angiography with clinical doses of Gd is technically feasible. Gd-based CTA seems a valuable alternative in patients with contraindications for iodine-based contrast media.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Compostos Heterocíclicos , Compostos Organometálicos , Intensificação de Imagem Radiográfica/métodos , Idoso , Aortografia/métodos , Angiografia Coronária/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Artéria Pulmonar/diagnóstico por imagem , Reprodutibilidade dos Testes
17.
Int J Cardiovasc Imaging ; 33(6): 889-897, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28138816

RESUMO

To prospectively compare image quality and myocardial T1 relaxation times of modified Look-Locker inversion recovery (MOLLI) imaging at 3.0 T (T) acquired with patient-adaptive dual-source (DS) and conventional single-source (SS) radiofrequency (RF) transmission. Pre- and post-contrast MOLLI T1 mapping using SS and DS was acquired in 27 patients. Patient wise and segment wise analysis of T1 times was performed. The correlation of DS MOLLI measurements with a reference spin echo sequence was analysed in phantom experiments. DS MOLLI imaging reduced T1 standard deviation in 14 out of 16 myocardial segments (87.5%). Significant reduction of T1 variance could be obtained in 7 segments (43.8%). DS significantly reduced myocardial T1 variance in 16 out of 25 patients (64.0%). With conventional RF transmission, dielectric shading artefacts occurred in six patients causing diagnostic uncertainty. No according artefacts were found on DS images. DS image findings were in accordance with conventional T1 mapping and late gadolinium enhancement (LGE) imaging. Phantom experiments demonstrated good correlation of myocardial T1 time between DS MOLLI and spin echo imaging. Dual-source RF transmission enhances myocardial T1 homogeneity in MOLLI imaging at 3.0 T. The reduction of signal inhomogeneities and artefacts due to dielectric shading is likely to enhance diagnostic confidence.


Assuntos
Cardiopatias/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Meios de Contraste/administração & dosagem , Feminino , Gadolínio DTPA/administração & dosagem , Cardiopatias/patologia , Humanos , Imagem Cinética por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Adulto Jovem
18.
PLoS One ; 11(9): e0162716, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27611830

RESUMO

OBJECTIVE: Evaluation of a new iterative reconstruction algorithm (IMR) for detection/rule-out of pulmonary embolism (PE) in ultra-low dose computed tomography pulmonary angiography (CTPA). METHODS: Lower dose CT data sets were simulated based on CTPA examinations of 16 patients with pulmonary embolism (PE) with dose levels (DL) of 50%, 25%, 12.5%, 6.3% or 3.1% of the original tube current setting. Original CT data sets and simulated low-dose data sets were reconstructed with three reconstruction algorithms: the standard reconstruction algorithm "filtered back projection" (FBP), the first generation iterative reconstruction algorithm iDose and the next generation iterative reconstruction algorithm "Iterative Model Reconstruction" (IMR). In total, 288 CTPA data sets (16 patients, 6 tube current levels, 3 different algorithms) were evaluated by two blinded radiologists regarding image quality, diagnostic confidence, detectability of PE and contrast-to-noise ratio (CNR). RESULTS: iDose and IMR showed better detectability of PE than FBP. With IMR, sensitivity for detection of PE was 100% down to a dose level of 12.5%. iDose and IMR showed superiority to FBP regarding all characteristics of subjective (diagnostic confidence in detection of PE, image quality, image noise, artefacts) and objective image quality. The minimum DL providing acceptable diagnostic performance was 12.5% (= 0.45 mSv) for IMR, 25% (= 0.89 mSv) for iDose and 100% (= 3.57 mSv) for FBP. CNR was significantly (p < 0.001) improved by IMR compared to FBP and iDose at all dose levels. CONCLUSION: By using IMR for detection of PE, dose reduction for CTPA of up to 75% is possible while maintaining full diagnostic confidence. This would result in a mean effective dose of approximately 0.9 mSv for CTPA.


Assuntos
Algoritmos , Angiografia por Tomografia Computadorizada , Pulmão/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Meios de Contraste/química , Relação Dose-Resposta à Radiação , Feminino , Humanos , Pulmão/patologia , Masculino , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/diagnóstico por imagem
20.
Clin Imaging ; 39(2): 231-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25481220

RESUMO

The purpose of this investigation was to systematically evaluate the spatial distribution of image quality improvement with dual-source radiofrequency (RF) transmission in cardiac steady-state free precession sequences at 3.0 T. Imaging with and without dual-source RF transmission was performed in 30 patients. Contrast-to-noise ratio for the left ventricular myocardium was significantly higher using dual-source RF transmission, but improvement was not uniformly distributed. The posterior myocardium showed significantly less contrast-to-noise ratio gain than all other cardiac regions. Signal-to-noise ratio increase was higher in the right than in the left ventricle. Subjective image quality was significantly enhanced by parallel RF transmission.


Assuntos
Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Adolescente , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Melhoria de Qualidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA