Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
1.
Skeletal Radiol ; 45(1): 35-40, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26298103

RESUMO

OBJECTIVE: The aim of this study is to determine the diagnostic accuracy of sonography in order to identify the chondral print on the humeral head. MATERIALS AND METHODS: In total, 44 patients who had already been candidates for arthroscopic surgery were prospectively studied with ultrasound to assess the presence of humeral subchondral erosion at the level of the biceps pulley; no patient had undergone previous surgery or radiographic calcification of rotator cuff tendons. Using arthroscopy as the reference standard the sensitivity, specificity, positive predictive, negative predictive and diagnostic accuracy values were calculated. RESULTS: Of the 44 patients, arthroscopy showed the humeral chondral print in 30 patients. Of the 30 arthroscopy proven humeral chondral prints, ultrasound identified 28 subchondral erosions at the same level, with two false negatives. One of the 14 patients without arthroscopic humeral chondral print was positive for subchondral erosion at ultrasound. The sensitivity, specificity, positive predictive, negative predictive, and diagnostic accuracy values of ultrasound were respectively of 93, 93, 96, 87 and 93%. CONCLUSION: Ultrasound has a good diagnostic accuracy in identifying the chondral print sign.


Assuntos
Cabeça do Úmero/diagnóstico por imagem , Instabilidade Articular/diagnóstico por imagem , Luxação do Ombro/diagnóstico por imagem , Tendinopatia/diagnóstico por imagem , Tendões/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Humanos , Cabeça do Úmero/patologia , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tendinopatia/patologia , Adulto Jovem
2.
Ann Plast Surg ; 76(1): 13-7, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26670133

RESUMO

BACKGROUND: Tumescent local anesthesia (TLA) technique to obtain regional anesthesia and vasoconstriction of the skin and subcutaneous tissues is routinely adopted for several plastic surgery procedures. Here, we describe the use of TLA in primary subglandular breast augmentation. This series evaluates advantages and disadvantages of TLA in elective augmentation breast surgery as well as patients' response to this procedure. METHODS: Between December 2008 and November 2011, 150 patients underwent bilateral primary subglandular breast augmentation under TLA and conscious sedation in the presence of a board-certified anesthesiologist. Midazolam 0.05 mg/kg IV and ranitidine 100 mg IV were given as premedication. Tumescent local anesthesia was composed of 25 mL of lidocaine 2%, 8 mEq of sodium bicarbonate, and 1 mL of epinephrine (1 mg/1 mL) in 1000 mL of 0.9% NS. The solution was delivered between the pectoral fascia and the mammary gland via a spinal needle. After infiltration, 45 minutes were allowed before surgery for local anesthetic effects to take place. RESULTS: The mean age of the patients was 34.3 years. The average amount of tumescent solution infiltrated was 1150 mL, with a maximal dose of 17 mg/kg of lidocaine used. Operating time was 45 minutes and recovery room time averaged 125 minutes. Minor complications were found in a total of 9 (5.3%) patients, with no main surgery-related complications such as hematoma or seroma formation. CONCLUSIONS: Breast augmentation under TLA and conscious sedation proved to be safe in the presence of a board-certified anesthesiologist and when performed with meticulous surgical technique.


Assuntos
Anestesia Local/métodos , Anestésicos Locais/administração & dosagem , Implante Mamário/métodos , Implantes de Mama , Medição da Dor , Dor Pós-Operatória/prevenção & controle , Adulto , Idoso , Implante Mamário/efeitos adversos , Estudos de Coortes , Estética , Feminino , Humanos , Itália , Pessoa de Meia-Idade , Dor Pós-Operatória/fisiopatologia , Satisfação do Paciente/estatística & dados numéricos , Seleção de Pacientes , Estudos Retrospectivos , Medição de Risco , Resultado do Tratamento
3.
Surg Radiol Anat ; 38(8): 893-902, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26932907

RESUMO

The anatomical variations of internal carotid artery (ICA) are mostly asymptomatic, thus being disregarded and only incidentally diagnosed, with very few symptomatic patients. The awareness of these anomalies is crucial to solve the differential with other neck lesions, preventing accidental injuries during neck surgery. Therefore, the aim of our study is to estimate the prevalence of ICA anomalies, using magnetic resonance angiography (MRA) and computed tomography angiography (CTA). 253 patients underwent head and neck MRA and CTA examinations, with multiplanar and volumetric reformations. For each set of images, the following items were investigated: origin, development, course, persistence of embryonic vessels and anomalous origin of collateral branches. In our series, ICA arose from the bifurcation of the common carotid artery at the level of: C4 in 303 hemi-necks (59.9 %); C3 in 98 hemi-necks (19.3 %); C5 in 57 hemi-necks (11.3 %); C2 in 48 hemi-necks (9.5 %). ICA kinking and/or coiling was found in 105 hemi-necks, and location variation of ICA (reversed-type) in two hemi-necks. In just one case the origin of the ascending pharyngeal artery was from ICA (0.2 %), while an anomalous persistence of the proatlantal artery was noticed in three cases (0.6 %). CTA and MRA showed similar accuracy in detecting ICA anomalies.


Assuntos
Variação Anatômica , Artéria Carótida Interna/anormalidades , Adulto , Idoso , Idoso de 80 Anos ou mais , Artéria Carótida Interna/diagnóstico por imagem , Malformações Vasculares do Sistema Nervoso Central/epidemiologia , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Itália/epidemiologia , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Prevalência
4.
J Vasc Interv Radiol ; 26(8): 1189-96, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26210246

RESUMO

PURPOSE: To retrospectively determine whether the application of thermal ablation to recurrent and advanced head and neck cancer (HNC) could allow for local tumor control. MATERIALS AND METHODS: From 2002 to 2014, 22 patients (17 men and 5 women; mean age, 64 y; age range, 42-88 y) with unresectable HNC lesions treated with thermal ablation were evaluated. Patients were followed at 3 and 6 months after treatment, every 6 months for 5 years, and yearly thereafter with computed tomography and/or magnetic resonance imaging. The mean follow-up period was 32.2 months (range, 3-51 mo). RESULTS: Three of 22 patients with primary lesions are still alive; two of these patients were treated with radiofrequency (RF) ablation and one was treated with microwave (MW) ablation. Of the 19 remaining patients, four were treated with MW ablation and 15 were treated with RF ablation. Imaging revealed partial response in eight patients, and complete response was observed in the remaining 14. There were two major complications after ablation treatment. The mean survival time was 32.9 months ± 3.205 (standard error; 95% confidence interval [CI], 26.6-39.2 mo). The survival time for MW ablation cases (36 mo ± 5.185; 95% CI, 25.8-46.16 mo) was longer than for RF ablation (32.2 mo ± 3.911; 95% CI, 24.5-39.8 mo), although the CI overlap between the groups is large. CONCLUSIONS: Percutaneous thermal ablation is a promising alternative treatment for local control of incurable HNC.


Assuntos
Ablação por Cateter/métodos , Neoplasias de Cabeça e Pescoço/patologia , Neoplasias de Cabeça e Pescoço/cirurgia , Micro-Ondas/uso terapêutico , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/prevenção & controle , Adulto , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Micro-Ondas/efeitos adversos , Pessoa de Meia-Idade , Projetos Piloto , Resultado do Tratamento
5.
Radiol Med ; 120(9): 810-23, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26088469

RESUMO

The use of multidetector CT (MDCT) represents a reality routinely used in several forensic institutes, for the numerous advantages that this diagnostic tool can provide; costs are becoming increasingly lower; data acquisition is always faster and once acquired may be revalued at any time. However, there are also some diagnostic limitations, for example, the visualization of the vascular system or a limited soft tissue contrast. In order to overcome these limitations, in recent years, contrast medium has been introduced in postmortem cases, with the development of several techniques of PMCT angiography (PMCTA) and standardized protocols to make them easily reproducible. The aim of this review is to highlight the advantages and pitfalls of PMCT and PMCTA in forensic investigation, taking into consideration the broad spectrum of applications both for natural and unnatural deaths and the numerous methods currently used. Secondly, in the light of the considerable progress in this field and the attempt to develop standardized protocols of PMCTA, the authors aim to evaluate the diagnostic value of PMCTA in comparison both to PMCT and conventional autopsy.


Assuntos
Angiografia/métodos , Medicina Legal/métodos , Tomografia Computadorizada por Raios X/métodos , Autopsia/métodos , Causas de Morte , Humanos , Mudanças Depois da Morte
6.
Radiol Med ; 120(1): 149-57, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25388991

RESUMO

PURPOSE: To evaluate safety and clinical efficacy of percutaneous transcatheter embolization (PTE) in the treatment of spontaneous bleedings (SBs) in patients submitted to chronic anticoagulation therapy. MATERIALS AND METHODS: From January 2007 to December 2012, 20 patients (mean age 75.8 years, range 68-91 years) with 23 SBs were retrospectively evaluated. Active bleeding was documented by contrast enhanced-multidetector row computed tomography (CE-MDCT). PTE was performed using different embolic agents. Technical success (TS), clinical success (CS), late success (LS) and mortality rate (M) related to the angiographic procedure and complications were evaluated. RESULTS: CE-MDCT and digital subtraction angiography (DSA) identified active bleeding sites in 18 cases (18/20). In two cases (2/20) DSA did not confirm the arterial bleeding diagnosed on CE-MDCT. Twenty-three sessions of PTE were performed. TS, CS, LS and M were, respectively, 100, 85, 15 and 0%. No major complications were observed. CONCLUSIONS: PTE could be considered a safe and effective "first line" approach to treat SB associated with anticoagulation therapy.


Assuntos
Anticoagulantes/efeitos adversos , Embolização Terapêutica/métodos , Hemorragia/induzido quimicamente , Hemorragia/terapia , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Meios de Contraste , Enoxaparina/efeitos adversos , Feminino , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Varfarina/efeitos adversos
7.
BMC Gastroenterol ; 14: 16, 2014 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-24447719

RESUMO

BACKGROUND: The aim is to assess the time-density curves (TDCs) and correlate the histologic results for small (≤ 2 cm) PDA and surrounding parenchyma at triphasic Multidetector-row CT (MDCT). METHODS: Triphasic MDCT scans of 38 consecutive patients who underwent surgery for a small PDA were retrospectively reviewed. The TDCs were analyzed and compared with histologic examination of the PDA and pancreas upstream/downstream in all cases. Three enhancement patterns were identified: 1) enhancement peak during pancreatic parenchymal phase (PPP) followed by a rapid decline on portal venous phase (PVP) and delayed phase (DP) at 5 minutes (type 1 pattern: normal pancreas); 2) maximum enhancement in PVP that gradually decreases in DP (type 2 pattern: mild chronic pancreatitis or PDA with mild fibrous stroma); 3) progressive enhancement with maximum peak in DP (type 3 pattern: severe chronic pancreatitis or PDA with severe fibrous stroma). A p value less than 0.05 was considered statistically significant. Sensitivity was calculated for PDA detection and an attenuation difference with the surrounding tissue of at least 10 HU was considered. RESULTS: PDA showed type 2 pattern in 5/38 cases (13.2%) and type 3 pattern in 33/38 cases (86,8%). Pancreas upstream to the tumor had type 2 pattern in 20/38 cases (52,6%) and type 3 pattern in 18/38 cases (47,4%). Pancreas downstream to the tumor had type 1 pattern in 19/25 cases (76%) and type 2 pattern in 6/25 cases (24%). Attenuation difference between tumor and parenchyma upstream was higher of 10 UH on PPP in 31/38 patients (sensitivity = 81.6%), on PVP in 29/38 (sensitivity = 76.3%) and on DP in 17/38 (sensitivity = 44.7%). Attenuation difference between tumor and parenchyma downstream was higher of 10 UH on PPP in 25/25 patients (sensitivity = 100%), on PVP in 22/25 (sensitivity = 88%) and on DP in 20/25 (sensitivity = 80%). Small PDAs were isodense to the pancreas upstream to the tumor, and therefore unrecognizable, in 8 cases (8/38; 21%) at qualitative analysis and in 4 cases (4/38; 10,5%) at quantitative analysis. CONCLUSIONS: The quantitative analysis increases the sensitivity for detection of small PDA at triphasic MDCT.


Assuntos
Carcinoma Ductal Pancreático/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Carcinoma Ductal Pancreático/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/patologia , Intensificação de Imagem Radiográfica , Estudos Retrospectivos , Sensibilidade e Especificidade
8.
Radiol Med ; 119(10): 729-40, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24496592

RESUMO

Interest in transthoracic ultrasound (US) procedures increased after the availability of portable US equipment suitable for use at the patient's bedside. It is possible to detect space-occupying lesions of the pleura, pleural effusion, focal or diffuse pleural thickening and subpleural lesions of the lung, even in emergency settings. Transthoracic US is useful as a guidance system for thoracentesis and peripheral lesion biopsy, where it minimises the occurrence of pneumothorax and haemorrhage. Transthoracic US imaging is strongly influenced by physical interaction of the ultrasonic beam at the tissue/air interface, which gives rise to reverberations classified as simple (A-line), "comet tail" and "ring down"(B-line) artifacts. Although these artifacts can be suggestive of a disease condition, they are essentially imaging errors present even in normal subjects and in empty-pleura post-pneumonectomy patients. In order to clarify some confusion and to report on the state of the art, we present a review of the literature on transthoracic US in diseases of the pleura and peripheral lung regions and our own clinical experience over 3 decades. The review focuses on quality assurance procedures and their value in diagnostic imaging and patient monitoring and warns against possible inappropriate indications and misleading information. Thoracic US is much more than "fishing for the moon in the well".


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Pneumopatias/diagnóstico por imagem , Pneumopatias/patologia , Doenças Pleurais/diagnóstico por imagem , Doenças Pleurais/patologia , Artefatos , Humanos , Valor Preditivo dos Testes , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia/métodos , Ultrassonografia de Intervenção/métodos
9.
Radiol Med ; 119(1): 64-74, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24234183

RESUMO

PURPOSE: This study assessed the role of whole-body (18)fluorodeoxyglucose positron-emission tomography/computed tomography ((18)FDG PET/CT) in the restaging and follow-up of patients with sarcoidosis previously studied by multidetector computed tomography (MDCT). MATERIALS AND METHODS: This retrospective study enrolled 21 patients to evaluate the sensitivity, specificity and accuracy of (18)FDG-PET/CT and MDCT. The results of the two techniques were compared with the Mc Nemar test. Cohen's K was used to compare concordance at the different lesion sites. RESULTS: The sensitivity, specificity and accuracy of (18)FDG-PET/CT were 80, 66.67, and 76.19 %, respectively. The sensitivity, specificity and accuracy of MDCT were 93.33, 33.33, and 76.19 %, respectively. In 16 patients who underwent whole-body MDCT, the sensitivity, specificity and accuracy values were 91.67, 81.25, and 50 % (MDCT) and 100, 50, and 87.5 % ((18)FDG-PET/CT). CONCLUSIONS: (18)FDG-PET/CT is useful in evaluating the extent of sarcoidosis and recognising lesions at different sites, including lymph nodes, lungs, liver, spleen and bone. It also improves the interpretation of the morphological lesions seen on MDCT and depicts a larger number of lesions. Therefore, (18)FDG-PET/CT could be used to complement other more traditional techniques for the restaging and follow-up in patients with sarcoidosis.


Assuntos
Imagem Multimodal , Tomografia por Emissão de Pósitrons/métodos , Sarcoidose/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Meios de Contraste , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Sensibilidade e Especificidade
10.
Radiol Med ; 119(7): 499-511, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25024061

RESUMO

Percutaneous radiofrequency ablation (PRFA) of renal malignancies is currently a therapeutic option for patients who are not able to undergo surgery. Some authors consider PRFA as the therapeutic standard in the treatment of renal neoplasms in non-operable patients due to comorbid conditions and in patients with mild-moderate renal failure, to preserve residual renal functionality. The use of PRFA has become more and more widespread due to a rise in the incidental detection of renal cell carcinomas with the ever-increasing use of Imaging for the study of abdominal diseases. Clinical studies indicate that RF ablation is an effective therapy with a low level of risk of complications, which provides good results in selected patients over short and medium term periods of time, however up to now few long-term studies have been carried out which can confirm the effectiveness of PRFA.


Assuntos
Carcinoma de Células Renais/cirurgia , Ablação por Cateter/métodos , Neoplasias Renais/cirurgia , Biópsia , Humanos , Imagem por Ressonância Magnética Intervencionista , Nefrectomia , Complicações Pós-Operatórias , Ondas de Rádio , Radiografia Intervencionista
11.
Radiol Med ; 119(7): 521-32, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25012472

RESUMO

C-arm cone-beam computed tomography (CBCT) is a new imaging technology integrated in modern angiographic systems. Due to its ability to obtain cross-sectional imaging and the possibility to use dedicated planning and navigation software, it provides an informed platform for interventional oncology procedures. In this paper, we highlight the technical aspects and clinical applications of CBCT imaging and navigation in the most common loco-regional oncological treatments.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Neoplasias/terapia , Radiografia Intervencionista , Técnicas de Ablação , Embolização Terapêutica/métodos , Desenho de Equipamento , Humanos , Neoplasias/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Cirurgia Assistida por Computador
12.
Minim Invasive Ther Allied Technol ; 23(2): 96-101, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24328985

RESUMO

AIM: To evaluate the usefulness and safety of percutaneous transluminal forceps biopsy in patients suspected of having a malignant biliary obstruction. MATERIAL AND METHODS: Forty consecutive patients (21 men and 19 women; mean age, 71.9 years) underwent forceps biopsy through percutaneous transhepatic biliary access performed to drain bile. Lesions involved the common bile duct (n 8), common hepatic duct (n 18), hilum (n 6), ampullary segment of the common bile duct (n 8) and were biopsied with 7-F biopsy forceps. Final diagnosis was confirmed with pathologic findings at surgery, or clinical and radiologic follow-up. RESULTS: Twenty-one of 40 biopsies resulted in correct diagnosis of malignancy. Thirteen biopsy diagnosis were proved to be true-negative. There were six false-negative and no false-positive diagnoses. Sensitivity, specificity and accuracy in aspecific biliary obstructions were 85%, 100% and 88,7% respectively. Sensitivity of biopsy in malignancies was higher than in benign obstructions (100% vs 68,4%, CI = 95%). Sensitivity was lower in the hilum tract and in the common bile duct than in other sites (CI = 95%). No major complications related to biopsy procedures occurred. CONCLUSIONS: Percutaneous transluminal forceps biopsy is a safe procedure, easy to perform through a transhepatic biliary drainage tract, providing high accuracy in the diagnosis of malignant biliary obstructions.


Assuntos
Neoplasias dos Ductos Biliares/patologia , Biópsia/métodos , Ducto Colédoco/patologia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Idoso , Idoso de 80 Anos ou mais , Biópsia/instrumentação , Drenagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Sensibilidade e Especificidade , Instrumentos Cirúrgicos
13.
J Vasc Interv Radiol ; 24(10): 1513-20, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24070507

RESUMO

PURPOSE: To evaluate the safety and efficacy of percutaneous microwave (MW) ablation treatment in locally advanced, nonresectable, nonmetastatic pancreatic head cancer. MATERIALS AND METHODS: Ten patients with pancreatic head cancer treated with percutaneous (n = 5) or laparotomic (n = 5) MW ablation were retrospectively reviewed. The MW generator used (45 W at 915 MHz) was connected by coaxial cable to 14-gauge straight MW antennas with a 3.7- or 2-cm radiating section. One or two antennae were used, with an ablation time of 10 minutes. Ultrasonographic (US) and combined US/cone-beam computed tomographic (CT) guidance were used in five patients each. Follow-up was performed by CT after 1, 3, 6, and, when possible, 12 months. Tumor response was assessed per Response Evaluation Criteria In Solid Tumors (version 1.1) and Choi criteria. The feasibility, safety, and major and minor complications associated with quality of life (QOL) were recorded prospectively. RESULTS: The procedure was feasible in all patients (100%). One late major complication was observed in one patient, and no visceral injury was detected. No patient had further surgery, and all minor complications resolved during the hospital stay. An improvement in QOL was observed in all patients despite a tendency to return to preoperative levels in the months following the procedure, without the influence of minor complications. No repeat treatment was performed. CONCLUSIONS: Despite the small number of patients, the present results can be considered encouraging, showing that MW ablation is a feasible approach in the palliative treatment of pancreatic tumors.


Assuntos
Eletrocoagulação/efeitos adversos , Eletrocoagulação/métodos , Laparotomia/métodos , Cisto Pancreático/etiologia , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/cirurgia , Pancreatite/etiologia , Idoso , Feminino , Humanos , Masculino , Micro-Ondas/efeitos adversos , Micro-Ondas/uso terapêutico , Cisto Pancreático/diagnóstico , Pancreatite/diagnóstico , Resultado do Tratamento
14.
Med Sci Monit ; 19: 95-101, 2013 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-23396358

RESUMO

BACKGROUND: Personalized cancer therapy remains a challenge. In this context, we attempted to identify correlations between tumour angiogenesis, tumour metabolism and tumour cell type. To this aim, we used single=phase multidetector computed tomography (MDCT) and hybrid positron emission tomography-computed tomography (PET/CT) to determine whether net enhancement and standardized uptake value (SUVmax) were correlated with tumour size and cytology in patients affected by non-small cell lung cancer (NSCLC). MATERIAL AND METHODS: Our study included 38 patients (30 men, 8 women, mean age 70) with a NSCLC measuring between 3 cm and 7 cm, using a 16-slice multidetector CT (Brilliance Philips) and with PET-CT (Biograph 16 Siemens Medical Solutions). The following lesion parameters were evaluated: maximum diameter, medium density before contrast injection (CTpre), medium density after contrast injection (CTpost average), density in the most enhanced part of the lesion after contrast (CTpost max), net enhancement, SUVmax, age, and cytology. Correlation coefficient and p-value were computed for each pair of variables. In addition, correlations were computed for each pair of variables, and for all combinations of tumour types. We focused on subsets of data with more than 10 observations, and with correlation r>0.500 and p<0.05. RESULTS: A weak correlation (r=0.32; p=0.048) was found between SUVmax and tumour size; the correlation was stronger for masses larger than 31 mm (r=0.4515; p=0.0268). No other correlations were found among the variables examined. CONCLUSIONS: Our data may have prognostic significance, and could lead to more appropriate surgical treatment and better treatment outcome.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Fluordesoxiglucose F18/farmacocinética , Neoplasias Pulmonares/diagnóstico por imagem , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Carga Tumoral , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Idoso , Carcinoma Pulmonar de Células não Pequenas/patologia , Meios de Contraste , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino
15.
Surg Radiol Anat ; 34(5): 393-9, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22215429

RESUMO

Aim of our study was to evaluate the prevalence of aberrant origin of the branches of the external carotid artery (ECA) in 97 patients by computed tomography (CTA) and magnetic resonance angiography (MRA) and to compare the accuracy of these two techniques in the visualization of the ECA system. All patients underwent CTA and MRA examination of the head and neck. Multiplanar and volumetric reformations were obtained in all cases. For each set of images, the presence of aberrant origin of the branches of the external carotid artery was investigated. MRA and CTA images of each patient were compared to define their information content. Anatomical anomalies were found in 88 heminecks, with a prevalence of 53.3%. In the 61 patients in whom the CTA was performed before the MRA, the latter method showed only 92% of abnormalities detected at the first examination; in the 36 patients in whom MRA was performed first, CTA identified all of the anomalies highlighted by the former, adding 12 new. Knowledge of the anomalies of origin of the ECA branches is essential for the head and neck surgeon; the high prevalence of anomalies found in our series as in the previous studies indicates the opportunity to perform a CTA or a MRA of the head and neck before any surgical or interventional procedure. CTA is the method of choice in the evaluation of anomalies of origin of the branches of the ECA and in the definition of their course.


Assuntos
Artéria Carótida Externa/anormalidades , Angiografia por Ressonância Magnética , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Estudos Retrospectivos
16.
Cardiovasc Ultrasound ; 9: 39, 2011 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-22151912

RESUMO

BACKGROUND: In recent years, several new technologies for small-animal imaging have been developed. In particular, the use of ultrasound in animal imaging has focused on the investigation of accessible biological structures such as the heart, of which it provides a morphological and functional assessment. The purpose of this study was to investigate the role of micro-ultrasonography (µ-US) in a longitudinal study on BIO14.6 cardiomyopathic hamsters treated with gene therapy. METHODS: Thirty hamsters were divided into three groups (n = 10): Group I, untreated BIO 14.6 hamsters; Group II, BIO 14.6 hamsters treated with gene therapy; Group III, untreated wild type (WT) hamsters. All hamsters underwent serial µ-US sessions and were sacrificed at predetermined time points. RESULTS: µ-US revealed: in Group I, progressive dilation of the left ventricle with a change in heart morphology from an elliptical to a more spherical shape, altered configuration of the mitral valve and subvalvular apparatus, and severe reduction in ejection fraction; in Group II, mild decrease in contractile function and ejection fraction; in Group III, normal cardiac chamber morphology and function. There was a negative correlation between the percentage of fibrosis observed at histology and the ejection fraction obtained on µ-echocardiography (Spearman r: -0.839; p < 0.001). CONCLUSIONS: Although histological examination remains indispensable for a conclusive diagnosis, high-frequency µ-echocardiography, thanks to the high spatial and contrast resolution, can be considered sufficient for monitoring therapeutic efficacy and/or the progression of dilated cardiomyopathy, providing an alternative tool for repeatable and noninvasive evaluation.


Assuntos
Cardiomiopatia Dilatada/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia Tridimensional/veterinária , Animais , Cricetinae , Estudos Longitudinais , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Abdom Imaging ; 36(4): 372-81, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20963584

RESUMO

OBJECTIVES: The aims of this study are: (a) to evaluate the reliability of Multidetector Computed Tomography Enteroclysis (MDCT-E) and (99m)Tc-HMPAO labeled leukocyte scintigraphy (TLLS), in inflammatory bowel disease, (b) to test the accuracy of the two techniques with regard to their histological results, (c) to define how each technique can influence the natural course of inflammatory bowel disease (IBD), (d) to assess the potential value of the two techniques combined. MATERIALS AND METHODS: Thirty-seven patients with suspected IBD underwent MDCT-E and TLLS. We made a separate assessment of the results shown by the two methods and then compared and contrasted the histological results of the two. The latter, however, were either disappointing or not available in 15 patients who, for this reason, had to be dismissed from the study. As result, the number of participants eventually dropped to 22 subjects: 12 women, 10 men with an average age of 44 years. RESULTS: MDCT-E and TLLS were successful in all patients. Sensitivity, specificity, and efficiency values have been reported as follows: MDCT-E: 62%, 100%, 64%,100%, 11%, respectively. TLLS: 90%, 100%, 91%, 100%, 33%, respectively. The two methods combined: 95%, 100%, 95%, 100%, 50%, respectively. CONCLUSIONS: The two techniques can be employed in different stages of the natural course of the disease. In our experience, TLLS proved itself to be useful in the diagnosis of the disease and the assessment of its development. Conversely, MDCT-E proved itself to be more reliable in identifying the seat and the extent of the disease inside and outside the bowel wall as well as potential intra-peritoneal and extra-intestinal complications. The combined use of the two methods represents the Criterion Standard for diagnosing IBD with imaging.


Assuntos
Doenças Inflamatórias Intestinais/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Exametazima , Tomografia Computadorizada por Raios X/métodos , Adulto , Biópsia , Distribuição de Qui-Quadrado , Meios de Contraste , Feminino , Humanos , Iopamidol/análogos & derivados , Leucócitos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Cintilografia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Respiration ; 80(6): 524-33, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20881375

RESUMO

BACKGROUND: (18)FDG-PET plays a significant role in diagnosing malignancy of lung lesions but remains an expensive test available at a limited number of sites in Italy. OBJECTIVE: We prospectively compare the diagnostic accuracy of (99m)Tc-MIBI- SPECT and (18)FDG-PET in patients with indeterminate lung lesions to demonstrate that (99m)Tc-MIBI-SPECT may be considered as a valid alternative when (18)FDG-PET is not available. METHODS: 52 patients with indeterminate lung lesion were examined by (18)FDG-PET and (99m)Tc-MIBI-SPECT before surgery. The scintigraphic findings were analyzed visually and semiquantitatively and then correlated to the definitive diagnosis. RESULTS: 38 were malignant lesions while 14 were benign. At visual analysis, the sensitivities of (18)FDG-PET and (99m)Tc-MIBI-SPECT were 92 and 84%, respectively (McNemar test p = 0.4), whereas the specificities were 78.6 and of 93% (p = 1.0), respectively. At semiquantitative analysis, (18)FDG-PET showed a sensitivity and specificity of 92 and 71.4%, respectively, while (99m)Tc-MIBI-SPECT produced a sensitivity and specificity of 86 and 100%, respectively (p = 0.194). For lymph node staging, (18)FDG-PET and (99m)Tc-MIBI-SPECT have a sensitivity and specificity of 88 and 92 of 77 and 100%, respectively. CONCLUSION: (99m)Tc-MIBI-SPECT is similar to (18)FDG-PET in the detection of lung malignancies and represents an alternative when PET is not available. Yet, the combination of both techniques may improve patient selection for surgery.


Assuntos
Carcinoma/diagnóstico por imagem , Fluordesoxiglucose F18 , Neoplasias Pulmonares/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Adulto , Idoso , Feminino , Humanos , Linfonodos/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Estudos Prospectivos
19.
Emerg Radiol ; 17(5): 361-5, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20393776

RESUMO

Intestinal pneumatosis (IP) has been traditionally associated with intestinal infarction and poor outcome in adults; recent studies have questioned its clinical value. To assess its diagnostic and prognostic significance, we have retrospectively evaluated 102 patients correlating the CT finding of gastrointestinal parietal gas with clinical data and outcome. Fifty-three patients (52%) had surgical evidence of intestinal infarction. In the remaining patients, a variety of lesions were found including intestinal obstruction, cancer, volvulus, ulcer, hernia, trauma, Crohn's disease, diverticulitis, and iatrogenic causes. We observed the presence of portal vein gas (PVG) associated to IP in 25.5% of cases. In patients having both IP and PVG, intestinal infarction was observed in 69.2% of cases. In our series, overall mortality was 30.4% (31/102), and when PVG was present, it rose to 50% (13/26). In our study, IP has been observed in a broad range of lesions with very different prognosis, the most frequent of which was intestinal infarction. When associated to PVG, there was a much higher prevalence of intestinal infarct, and the prognosis was definitively worse.


Assuntos
Pneumatose Cistoide Intestinal/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pneumatose Cistoide Intestinal/diagnóstico por imagem , Pneumatose Cistoide Intestinal/cirurgia , Prognóstico , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA