Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Sensors (Basel) ; 22(9)2022 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-35591082

RESUMO

Two novel metal-organic frameworks (MOFs), based on dysprosium as the metal and the 5-aminoisophthalic acid (5aip) ligand, have been solvothermally synthesized, with the aim of studying and modulating their luminescence properties according to the variation of solvent in the structure. These materials display intense photo-luminescence properties in the solid state at room temperature. Interestingly, one fascinating sensory capacity of compound 2 regards obtaining a variation of the signal, depending on the solvent to which it is exposed. These results pave the way for a new generation of sensitive chemical sensors.

2.
Sensors (Basel) ; 22(4)2022 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-35214565

RESUMO

Herein, we present the syntheses of a novel coordination polymer (CP) based on the perylene-3,4,9,10-tetracarboxylate (pery) linkers and sodium metal ions. We have chosen sodium metal center with the aim of surmising the effect that the modification of the metal ion may have on the relative humidity (RH) experimental measurements of the material. We confirm the role of the ions in the functionalization of the deposited layer by modifying their selectivity towards moisture content, paving the way to the generation of sensitive and selective chemical sensors.

3.
Sensors (Basel) ; 22(1)2021 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-35009811

RESUMO

Tetracycline (TC) is a widely known antibiotic used worldwide to treat animals. Its residues in animal-origin foods cause adverse health effects to consumers. Low-cost and real-time measuring systems of TC in food samples are, therefore, extremely needed. In this work, a three-electrode sensitive and label-free sensor was developed to detect TC residues from milk and meat extract samples, using CO2 laser-induced graphene (LIG) electrodes modified with gold nanoparticles (AuNPs) and a molecularly imprinted polymer (MIP) used as a synthetic biorecognition element. LIG was patterned on a polyimide (PI) substrate, reaching a minimum sheet resistance (Rsh) of 17.27 ± 1.04 Ω/sq. The o-phenylenediamine (oPD) monomer and TC template were electropolymerized on the surface of the LIG working electrode to form the MIP. Surface morphology and electrochemical techniques were used to characterize the formation of LIG and to confirm each modification step. The sensitivity of the sensor was evaluated by differential pulse voltammetry (DPV), leading to a limit of detection (LOD) of 0.32 nM, 0.85 nM, and 0.80 nM in buffer, milk, and meat extract samples, respectively, with a working range of 5 nM to 500 nM and a linear response range between 10 nM to 300 nM. The sensor showed good LOD (0.32 nM), reproducibility, and stability, and it can be used as an alternative system to detect TC from animal-origin food products.


Assuntos
Grafite , Nanopartículas Metálicas , Impressão Molecular , Animais , Antibacterianos , Técnicas Eletroquímicas , Eletrodos , Ouro , Lasers , Limite de Detecção , Carne , Leite , Polímeros Molecularmente Impressos , Polímeros , Reprodutibilidade dos Testes , Tetraciclina
4.
Mikrochim Acta ; 187(7): 421, 2020 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-32617684

RESUMO

A microfluidic paper-based analytical device integrating carbon dot (CDs) is fabricated and used for a fluorometric off-on assay of biothiols. Vinyl sulfone (VS) click immobilization of carbon dots (CDs) on paper was accomplished by a one-pot simplified protocol that uses divinyl sulfone (DVS) as a homobifunctional reagent. This reagent mediated both the click oxa-Michael addition to the hydroxyl groups of cellulose and ulterior covalent grafting of the resulting VS paper to NH2-functionalized CDs by means of click aza-Michael addition. The resulting cellulose nanocomposite was used to engineer an inexpensive and robust microfluidic paper-based analytical device (µPAD) that is used for a reaction-based off-on fluorometric assay of biothiols (GSH, Cys, and Hcy). The intrinsic blue fluorescence of CDs (with excitation/emission maxima at 365/450 nm) is turned off via the heavy atom effect of an introduced iodo group. Fluorescence is turned on again due to the displacement of iodine by reaction with a biothiol. The increase in fluorescence is related to the concentration over a wide range (1 to 200 µM for GSH and 5-200 µM for Cys and Hcy, respectively), and the assay exhibits a low detection limit (0.3 µM for GSH and Cys and 0.4 µM for Hcy). The method allows for rapid screening and can also be used in combination with a digital camera readout. Graphical abstract Schematic representation of a µPAD based on click immobilized carbon dots and used for a reaction-based fluorometric off-on assay of biothiols. The intrinsic blue fluorescence of carbon dots is turned off via the heavy atom effect of an introduced iodo group and turned on by the displacement of this atom by reaction with a biothiol.


Assuntos
Cisteína/urina , Glutationa/urina , Homocisteína/urina , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/métodos , Pontos Quânticos/química , Carbono/química , Química Click , Humanos , Técnicas Analíticas Microfluídicas/instrumentação , Papel , Espectrometria de Fluorescência/métodos , Sulfonas/química
5.
Sensors (Basel) ; 20(23)2020 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-33297313

RESUMO

In this letter, we present the extension of a previous work on a cost-effective method for fabricating highly sensitive humidity sensors on flexible substrates with a reversible response, allowing precise monitoring of the humidity threshold. In that work we demonstrated the use of three-dimensional metal-organic framework (MOF) film deposition based on the perylene-3,4,9,10-tetracarboxylate linker, potassium as metallic center and the interspacing of silver interdigitated electrodes (IDEs) as humidity sensors. In this work, we study one of the most important issues in efficient and reproducible mass production, which is to optimize the most important processes' parameters in their fabrication, such as controlling the thickness of the sensor's layers. We demonstrate this method not only allows for the creation of humidity sensors, but it also is possible to change the humidity value that changes the actuator state.

6.
Anal Chem ; 91(13): 8644-8651, 2019 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-31194514

RESUMO

Herein, the reproducibility and a double validation of on-body measurements provided by new wearable potentiometric ion sensors (WPISs) is presented. Sweat collected during sport practice was first analyzed using the developed device, the pH-meter, and ion chromatography (IC) prior to on-body measurements (off-site validation). Subsequently, the accuracy of on-body measurements accomplished by the WPISs was evaluated by comparison with pH-meter readings and IC after collecting sweat (every 10-12.5 min) during sport practice. The developed device contains sensors for pH, Cl-, K+, and Na+ that are embedded in a flexible sampling cell for sweat analysis. The electrode array was fabricated employing MWCNTs (as an ion-to-electron transducer) and stretchable materials that have been exhaustively characterized in terms of analytical performance, presenting Nernstian slopes within the expected physiological range of each ion analyte (Cl-, 10-100 mM; K+, 10-10 mM; and Na+, 10-100 mM and pH, 4.5-7.5), drift suitable for midterm exercise practice (0.3 ± 0.2 mV h-1), fast response time, adequate selectivity for sweat measurements, and excellent reversibility. Besides that, the designed sampling cell avoids any sweat contamination and evaporation issues while supplying a passive sweat flow encompassing specifically the individual's perspiration. The interpretation of ion concentration profiles may permit the identification of personal dynamic patterns in sweat composition while practicing sport.


Assuntos
Técnicas Biossensoriais/instrumentação , Eletrodos , Íons/análise , Monitorização Fisiológica/métodos , Potenciometria/instrumentação , Suor/química , Dispositivos Eletrônicos Vestíveis , Exercício Físico , Humanos , Concentração de Íons de Hidrogênio , Reprodutibilidade dos Testes
7.
Mikrochim Acta ; 185(1): 47, 2017 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-29594561

RESUMO

This work presents a microfluidic paper-based analytical device (µPAD) for glucose determination using a supported metal-organic framework (MOF) acting as a peroxidase mimic. The catalytic action of glucose oxidase (GOx) on glucose causes the formation of H2O2, and the MOF causes the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) by H2O2 to form a blue-green product with an absorption peak at 650 nm in the detection zone. A digital camera and the iOS feature of a smartphone are used for the quantitation of glucose with the S coordinate of the HSV color space as the analytical parameter. Different factors such as the concentration of TMB, GOx and MOF, pH and buffer, sample volume, reaction time and reagent position in the µPAD were optimized. Under optimal conditions, the value for the S coordinate increases linearly up to 150 µmol·L-1 glucose concentrations, with a 2.5 µmol·L-1 detection limit. The µPAD remains stable for 21 days under conventional storage conditions. Such an enzyme mimetic-based assay to glucose determination using Fe-MIL-101 MOF implemented in a microfluidic paper-based device possesses advantages over enzyme-based assays in terms of costs, durability and stability compared to other existing glucose determination methods. The procedure was applied to the determination of glucose in (spiked) serum and urine. Graphical abstract Schematic representation of microfluidic paper-based analytical device using metal-organic framework as a peroxidase mimic for colorimetric glucose detection with digital camera or smartphone and iOS app readout.

8.
Bioconjug Chem ; 27(3): 549-61, 2016 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-26841323

RESUMO

Gene transfection mediated by the cationic polymer polyethylenimine (PEI) is considered a standard methodology. However, while highly branched PEIs form smaller polyplexes with DNA that exhibit high transfection efficiencies, they have significant cell toxicity. Conversely, low molecular weight PEIs (LMW-PEIs) with favorable cytotoxicity profiles display minimum transfection activities as a result of inadequate DNA complexation and protection. To solve this paradox, a novel polyelectrolyte complex was prepared by the ionic cross-linking of branched 1.8 kDa PEI with citric acid (CA). This system synergistically exploits the good cytotoxicity profile exhibited by LMW-PEI with the high transfection efficiencies shown by highly branched and high molecular weight PEIs. The polyectrolyte complex (1.8 kDa-PEI@CA) was obtained by a simple synthetic protocol based on the microwave irradiation of a solution of 1.8 kDa PEI and CA. Upon complexation with DNA, intrinsic properties of the resulting particles (size and surface charge) were measured and their ability to form stable polyplexes was determined. Compared with unmodified PEIs the new complexes behave as efficient gene vectors and showed enhanced DNA binding capability associated with facilitated intracellular DNA release and enhanced DNA protection from endonuclease degradation. In addition, while transfection values for LMW-PEIs are almost null, transfection efficiencies of the new reagent range from 2.5- to 3.8-fold to those of Lipofectamine 2000 and 25 kDa PEI in several cell lines in culture such as CHO-k1, FTO2B hepatomas, L6 myoblasts, or NRK cells, simultaneously showing a negligible toxicity. Furthermore, the 1.8 kDa-PEI@CA polyelectrolyte complexes retained the capability to transfect eukaryotic cells in the presence of serum and exhibited the capability to promote in vivo transfection in mouse (as an animal model) with an enhanced efficiency compared to 25 kDa PEI. Results support the polyelectrolyte complex of LMW-PEI and CA as promising generic nonviral gene carriers.


Assuntos
Ácido Cítrico/química , Eletrólitos/química , Polietilenoimina/química , Transfecção , Linhagem Celular , Humanos , Técnicas In Vitro , Peso Molecular
9.
Anal Bioanal Chem ; 408(11): 3013-20, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26869344

RESUMO

A portable reconfigurable platform for copper (Cu(II)) determination based on luminescent carbon dot (Cdots) quenching is described. The electronic setup consists of a light-emitting diode (LED) as the carbon dot optical exciter and a photodiode as a light-to-current converter integrated in the same instrument. Moreover, the overall analog conditioning is simply performed with one integrated solution, a field-programmable analog array (FPAA), which makes it possible to reconfigure the filter and gain stages in real time. This feature provides adaptability to use the platform as an analytical probe for carbon dots coming from different batches with some variations in luminescence characteristics. The calibration functions obtained that fit a modified Stern-Volmer equation were obtained using luminescence signals from Cdots quenching by Cu(II). The analytical applicability of the reconfigurable portable instrument for Cu(II) using Cdots has been successfully demonstrated in tap water analysis.


Assuntos
Carbono/química , Cobre/análise , Luminescência , Padrões de Referência , Difração de Raios X
10.
Bioconjug Chem ; 25(6): 1151-61, 2014 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-24852962

RESUMO

The receptor for advanced glycation end products (RAGE) is involved in diabetes or angiogenesis in tumors. Under pathological conditions, RAGE is overexpressed and upon ligand binding and internalization stimulates signaling pathways that promote cell proliferation. In this work, amino dendritic polymers PEI 25 kDa and alkylated derivatives of PAMAM-G2 were engineered by the nonenzymatic Maillard glycation reaction to generate novel AGE-containing gene delivery vectors targeting the RAGE. The glycated dendritic polymers were easily prepared and retained the capability to bind and protect DNA from endonucleases. Furthermore, while glycation decreased the transfection efficiency of the dendriplexes in CHO-k1 cells which do not express RAGE, glycated dendriplexes acted as efficient transfection reagents in CHO-k1 cells which stably express recombinant RAGE. In addition, preincubation with BSA-AGEs, a natural ligand of the RAGE, or dansyl cadaverine, an inhibitor of the RAGE internalization, blocked transfection, confirming their specificity toward RAGE. The results were confirmed in NRK and RAW264.7 cell lines, which naturally express the receptor. The glycated compounds retain their transfection efficiency in the presence of serum and promote in vivo transfection in a mouse model. Accordingly, RAGE is a suitable molecular target for the development of site-directed engineered glycated nonviral gene vectors.


Assuntos
Dendrímeros/química , Técnicas de Transferência de Genes , Engenharia Genética , Vetores Genéticos/química , Polímeros/química , Receptores Imunológicos/química , Animais , Células CHO , Cadaverina/análogos & derivados , Cadaverina/farmacologia , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Cricetulus , Dendrímeros/administração & dosagem , Dendrímeros/síntese química , Dendrímeros/farmacologia , Relação Dose-Resposta a Droga , Feminino , Vetores Genéticos/síntese química , Vetores Genéticos/farmacologia , Camundongos , Modelos Biológicos , Tamanho da Partícula , Polímeros/síntese química , Polímeros/farmacologia , Ratos , Receptor para Produtos Finais de Glicação Avançada , Receptores Imunológicos/antagonistas & inibidores , Receptores Imunológicos/metabolismo , Relação Estrutura-Atividade , Propriedades de Superfície
11.
Dalton Trans ; 53(29): 12138-12151, 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-38989768

RESUMO

In this work, we report on five novel coordination polymers (CPs) based on the linkage of the [Cd(6apic)2] building block [where 6apic = 6-aminopicolinate] by different bipyridine-type organic spacers, forming different coordination compounds with the following formulae: [Cd(µ-6apic)2]n (1), {[Cd(6apic)2(µ-bipy)]·H2O}n (2), {[Cd(6apic)2(µ-bpe)]·2H2O}n (3), [Cd(6apic)(µ-6apic)(µ-bpa)0.5]n (4) and {[Cd2(6apic)4(µ-tmbp)]·7H2O}n (5) [where bipy = 4,4'-bipyridine, bpe = 1,2-di(4-pyridyl)ethylene, bpa = 1,2-di(4-pyridyl)ethane (bpa) and tmbp = 1,3-di(4-pyridyl)propane]. Most of the synthesized compounds form infinite metal-organic rods through the linkage of the building block by the bipyridine-type linker, except in the case of compound 4 whose assembly forms a densely packed 3D architecture. All compounds were fully characterized and their photoluminescence properties were studied experimentally and computationally through density functional theory (DFT) calculations. All compounds display, upon UV excitation, a similar blue emission of variable intensity depending on the linker employed for the connection of the building units, among which compound 2 deserves to be highlighted for its room temperature phosphorescence (RTP) with an emission lifetime of 32 ms that extends to 79 ms at low temperature. These good photoluminescence properties, in addition to its stability in water over a wide pH range (between 2 and 10), motivated us to study compound 2 as a sensor for the detection of metal ions in water, and it showed high sensitivity to Fe3+ through a fluorescence turn-off mechanism and an unspecific turn-on response to Zn2+. Furthermore, the compound is processed as a paper-based analytical device (PAD) in which the phosphorescence emission is preserved, improving the sensing capacity toward Fe3+ ions.

12.
Dalton Trans ; 53(28): 11750-11761, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-38938108

RESUMO

Two novel Ce(III) metal organic frameworks (MOFs) with formulas [Ce(5Meip)(H-5Meip)]nGR-MOF-17 and [CeCl(5Meip)(DMF)]nGR-MOF-18 (5Meip = 5-methylisophthalate, DMF = N,N-dimethylformamide) have been synthesized, forming 3-dimensional frameworks. Magnetic measurements show that both compounds present field-induced slow magnetic relaxation under a small applied dc field. For GR-MOF-17, the temperature dependence of relaxation times is best described by a Raman mechanism, whereas for GR-MOF-18, relaxation occurs through a combination of Raman and local-mode pathways. Moreover, when avoiding short Ce⋯Ce interactions by magnetic dilution in GR-MOF-17@La and GR-MOF-18@La, only the local-mode mechanism is responsible for magnetic relaxation. Photophysical studies show the occurrence of ligand-centred luminescence in both compounds and phosphorescence emission at low temperature for GR-MOF-17.

13.
Inorg Chem ; 52(2): 546-8, 2013 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-23286441

RESUMO

We report the synthesis of a novel ligand, 3,3'-(1,2,4,5-tetrazine-3,6-diyl)dibenzoic acid (1). In this fragment, we have introduced two carboxylate groups with the aim of using this ligand as a linker to construct three-dimensional metal-organic frameworks (MOFs). We have been successful in the formation of zinc (2) and lanthanum (3) MOFs. The zinc compound is a two-dimensional structure, while the lanthanum material is a three-dimensional MOF with interesting channels. We include the luminescence and adsorption studies of these materials. Moreover, we have evaluated the in vitro toxicity of this novel ligand, concluding that it can be considered negligible.


Assuntos
Benzoatos/síntese química , Compostos Heterocíclicos/síntese química , Compostos Organometálicos/síntese química , Adsorção , Animais , Benzoatos/química , Sobrevivência Celular , Células Cultivadas , Cristalografia por Raios X , Compostos Heterocíclicos/química , Humanos , Lantânio/química , Luminescência , Compostos Organometálicos/química , Compostos Organometálicos/metabolismo , Zinco/química
14.
Biosensors (Basel) ; 13(2)2023 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-36832033

RESUMO

Here, we propose a microfluidic paper-based analytical device (µPAD) implemented with a near-field communication (NFC) tag as a portable, simple and fast colorimetric method for glutathione (GSH) determination. The proposed method was based on the fact that Ag+ could oxidize 3,3',5,5'-tetramethylbenzidine (TMB) into oxidized blue TMB. Thus, the presence of GSH could cause the reduction of oxidized TMB, which resulted in a blue color fading. Based on this finding, we developed a method for the colorimetric determination of GSH using a smartphone. A µPAD implemented with the NFC tag allowed the harvesting of energy from a smartphone to activate the LED that allows the capture of a photograph of the µPAD by the smartphone. The integration between electronic interfaces into the hardware of digital image capture served as a means for quantitation. Importantly, this new method shows a low detection limit of 1.0 µM. Therefore, the most important features of this non-enzymatic method are high sensitivity and a simple, fast, portable and low-cost determination of GSH in just 20 min using a colorimetric signal.


Assuntos
Colorimetria , Glutationa , Colorimetria/métodos , Benzidinas , Smartphone , Limite de Detecção
15.
Chem Commun (Camb) ; 58(10): 1514-1517, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34994366

RESUMO

A new palladium coordination compound based on gliclazide with the chemical formula [Pd(glz)2] (where glz = gliclazide) has been synthesized and characterised. The structural characterization reveals that this material consists of mononuclear units formed by a Pd2+ ion coordinated to two molecules of the glz ligand, in which palladium ions exhibit a distorted plane-square coordination sphere. This novel material behaves like a good and selective inhibitor of butyrylcholinesterase, one of the most relevant therapeutic targets against Alzheimer's disease. Analysis of the enzyme kinetics showed a mixed mode of inhibition, the title compound being capable of interacting with both the free enzyme and the enzyme-substrate complex. Finally, the palladium compound shows promising protective activity against Aß-induced toxicity in the Caenorhabditis elegans model, which has never been reported.


Assuntos
Caenorhabditis elegans/efeitos dos fármacos , Complexos de Coordenação/química , Gliclazida/química , Paládio/química , Substâncias Protetoras/farmacologia , Doença de Alzheimer/tratamento farmacológico , Peptídeos beta-Amiloides/metabolismo , Peptídeos beta-Amiloides/farmacologia , Animais , Butirilcolinesterase/química , Butirilcolinesterase/metabolismo , Complexos de Coordenação/metabolismo , Complexos de Coordenação/farmacologia , Complexos de Coordenação/uso terapêutico , Modelos Animais de Doenças , Conformação Molecular , Substâncias Protetoras/química , Substâncias Protetoras/metabolismo , Substâncias Protetoras/uso terapêutico
16.
ACS Sens ; 7(1): 37-43, 2022 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-35020353

RESUMO

Here we present a new approach for the development of fluoride chemosensors taking advantage of aggregation induced emission (AIE) properties. Although AIE-based chemosensors have been described, they rely primarily on the analyte causing aggregation and hence fluorescence. We propose a new concept in the use of AIE for the development of fluorescent sensors. Our hypothesis is based on the fact that a turn-off chemosensor in solution can be transformed into turn-on in the solid state if the properties of ACQ and AIE are properly combined between the fluorescent molecules involved. To demonstrate this hypothesis, we have selected a fluorescent chemosensor for the fluoride anion with a conjugated structure of bis(styryl)pyrimidine that, while showing turn-off behavior in solution, becomes turn-on when it is brought to the solid state. We have also combined it with the advantages of a detection system based on the microfluidic paper-based analytical devices (µPAD). The system is fully characterized spectroscopically both in solution and in the solid state, and quantum mechanical calculations were performed to explain how the sensor works. The prepared device presents a high sensitivity, with no interference and with an LoD and LoQ that allow determination of fluoride concentrations in water 2 orders of magnitude below the maximum allowed by WHO.


Assuntos
Corantes Fluorescentes , Fluoretos , Ânions , Corantes Fluorescentes/química , Água/química
17.
Nanomaterials (Basel) ; 12(22)2022 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-36432263

RESUMO

The work presented herein reports on the synthesis, structural and physico-chemical characterization, luminescence properties and luminescent sensing activity of a family of isostructural coordination polymers (CPs) with the general formula [Ln2(µ4-5Meip)3(DMF)]n (where Ln(III) = Sm (1Sm), Eu (2Eu), Gd (3Gd), Tb (4Tb) and Yb (5Yb) and 5Meip = 5-methylisophthalate, DMF = N,N-dimethylmethanamide). Crystal structures consist of 3D frameworks tailored by the linkage between infinite lanthanide(III)-carboxylate rods by means of the tetradentate 5Meip ligands. Photoluminescence measurements in solid state at variable temperatures reveal the best-in-class properties based on the capacity of the 5Meip ligand to provide efficient energy transfers to the lanthanide(III) ions, which brings intense emissions in both the visible and near-infrared (NIR) regions. On the one hand, compound 5Yb displays characteristic lanthanide-centered bands in the NIR with sizeable intensity even at room temperature. Among the compounds emitting in the visible region, 4Tb presents a high QY of 63%, which may be explained according to computational calculations. At last, taking advantage of the good performance as well as high chemical and optical stability of 4Tb in water and methanol, its sensing capacity to detect 2,4,6-trinitrophenol (TNP) among other nitroaromatic-like explosives has been explored, obtaining high detection capacity (with Ksv around 105 M-1), low limit of detection (in the 10-6-10-7 M) and selectivity among other molecules (especially in methanol).

18.
Anal Chem ; 83(7): 2712-8, 2011 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-21370833

RESUMO

The synthesis and characterization of a novel water-compatible microsized material, based on fluorescent conjugated polymers (CPs), and its applicability for optical sensing of inorganic ions of environment interest (copper and cyanide) in water media is here described. Polyfluorene-based fluorescent CPs were synthesized and functionalized with imidazole moieties (selective recognition element) and a terminal double bond (covalently linked to an organic matrix) through a postfunctionalization strategy. Further, microspheres of the novel imidazole-functionalized fluorescent CPs, able to work in water media, were synthesized via a microemulsion and polymerization procedure. The synthesized imidazole-functionalized CP microspheres were then evaluated as fluorescence "turn-Off" sensing materials for Cu(2+) detection in aqueous media. Analyte detection was based on the quenching effect of the Cu(2+), selectively recognized by the imidazole group, on the polymer fluorescence emission. The developed optosensor exhibits a detection limit of 1 µg/L for the determination of Cu(2+) in water with a reproducibility of 4%. The synthesized microsized material was also evaluated for the "turn-on" optosensing of cyanide in water, measuring the recovery of the emission signal from the CP that has been previously deactivated by the presence of quencher species. The "turn-On" optosensor allows the selective determination of free cyanide in aqueous solution with high sensitivity (detection limit of 18 µg/L), obtaining a reproducibility of 2.9%. A high sample throughput (between 7 and 12 samples per hour) was achieved in both cases. Analytical applicability of the fluorescent CP microsphere materials has been successfully demonstrated by tap and mineral water analysis.


Assuntos
Cobre/análise , Cianetos/análise , Microesferas , Fenômenos Ópticos , Polímeros/química , Água/química , Cobre/química , Cianetos/química , Concentração de Íons de Hidrogênio , Imidazóis/química , Concentração Osmolar , Polímeros/síntese química , Espectrometria de Fluorescência
19.
Sci Rep ; 11(1): 3947, 2021 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-33597607

RESUMO

Encapsulation of magnetic nanoparticles (MNPs) of iron (II, III) oxide (Fe3O4) with a thermopolymeric shell of a crosslinked poly(2-(2-methoxyethoxy)ethyl methacrylate) P(MEO2MA) is successfully developed. Magnetic aggregates of large size, around 150-200 nm are obtained during the functionalization of the iron oxide NPs with vinyl groups by using 3-butenoic acid in the presence of a water soluble azo-initiator and a surfactant, at 70 °C. These polymerizable groups provide a covalent attachment of the P(MEO2MA) shell on the surface of the MNPs while a crosslinked network is achieved by including tetraethylene glycol dimethacrylate in the precipitation polymerization synthesis. Temperature control is used to modulate the swelling-to-collapse transition volume until a maximum of around 21:1 ratio between the expanded: shrunk states (from 364 to 144 nm in diameter) between 9 and 49 °C. The hybrid Fe3O4@P(MEO2MA) microgel exhibits a lower critical solution temperature of 21.9 °C below the corresponding value for P(MEO2MA) (bulk, 26 °C). The MEO2MA coating performance in the hybrid microgel is characterized by dynamic light scattering and transmission electron microscopy. The content of preformed MNPs [up to 30.2 (wt%) vs. microgel] was established by thermogravimetric analysis while magnetic properties by vibrating sample magnetometry.

20.
Colloids Surf B Biointerfaces ; 196: 111337, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32949922

RESUMO

The determination of creatinine levels is essential for the detection of renal and muscular dysfunction. Luminescent nanoparticles are emerging as fast, cheap and highly selective sensors for the detection and quantification of creatinine. Nevertheless, current nanosensors only have a short shelf life due to their poor chemical and colloidal stability, which limits their clinical functionality. In this work, we have developed a highly stable, selective and sensitive nanosensor based on europium-doped, amorphous calcium phosphate nanoparticles (Eu-ACP) for the determination of creatinine by luminescence spectroscopy. The colloidal stability of Eu-ACP nanoparticles in aqueous solutions was optimised to ensure a constant signal after up to 4 months in storage. The luminescence intensity of Eu-ACP decreased linearly with the creatinine concentration over the range of 1-120 µM (R2 = 0.995). This concentration-response relationship was used to determine creatinine levels in real urine samples resulting in good recovery percentages. Significantly, selectivity assays indicated that none of the potential interfering species provoked discernible changes in the luminescence intensity.


Assuntos
Európio , Nanopartículas , Fosfatos de Cálcio , Creatinina , Luminescência , Medições Luminescentes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA