Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.904
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Circulation ; 149(15): e1090-e1107, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38450477

RESUMO

Balloon pulmonary angioplasty continues to gain traction as a treatment option for patients with chronic thromboembolic pulmonary disease with and without pulmonary hypertension. Recent European Society of Cardiology guidelines on pulmonary hypertension now give balloon pulmonary angioplasty a Class 1 recommendation for inoperable and residual chronic thromboembolic pulmonary hypertension. Not surprisingly, chronic thromboembolic pulmonary hypertension centers are rapidly initiating balloon pulmonary angioplasty programs. However, we need a comprehensive, expert consensus document outlining critical concepts, including identifying necessary personnel and expertise, criteria for patient selection, and a standardized approach to preprocedural planning and establishing criteria for evaluating procedural efficacy and safety. Given this lack of standards, the balloon pulmonary angioplasty skill set is learned through peer-to-peer contact and training. This document is a state-of-the-art, comprehensive statement from key thought leaders to address this gap in the current clinical practice of balloon pulmonary angioplasty. We summarize the current status of the procedure and provide a consensus opinion on the role of balloon pulmonary angioplasty in the overall care of patients with chronic thromboembolic pulmonary disease with and without pulmonary hypertension. We also identify knowledge gaps, provide guidance for new centers interested in initiating balloon pulmonary angioplasty programs, and highlight future directions and research needs for this emerging therapy.


Assuntos
Angioplastia com Balão , Hipertensão Pulmonar , Embolia Pulmonar , Tromboembolia , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/terapia , Embolia Pulmonar/complicações , Embolia Pulmonar/terapia , American Heart Association , Doença Crônica , Artéria Pulmonar , Endarterectomia
2.
Am J Transplant ; 24(5): 818-826, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38101475

RESUMO

To evaluate outcomes of patients undergoing heart transplants (HTs) using an intra-aortic balloon pump (IABP) under exception status. Adult patients supported by an IABP who underwent HT between November 18, 2018, and December 31, 2020, as documented in the United Network for Organ Sharing, were included. Patients were stratified according to requests for exception status. Kaplan-Meier methodology was used to look for differences in survival between groups. A total of 1284 patients were included; 492 (38.3%) were transplanted with an IABP under exception status. Exception status patients had higher body mass index, were more likely to be Black, and had longer waitlist times. Exception status patients received organs from younger donors, had a shorter ischemic time, and had a higher frequency of sex mismatch. The 1-year posttransplant survival was 93% for the nonexception and 88% for the exception IABP patients (hazard ratio: 1.85 [95% confidence interval: 1.12-2.86, P = .006]). The most common reason for requesting an exception status was inability to meet blood pressure criteria for extension (37% of patients). The most common reason for an extension request for an exception status was right ventricular dysfunction (24%). IABP patients transplanted under exception status have an increased 1-year mortality rate posttransplant compared with those without exception status.


Assuntos
Sobrevivência de Enxerto , Transplante de Coração , Balão Intra-Aórtico , Obtenção de Tecidos e Órgãos , Listas de Espera , Humanos , Transplante de Coração/mortalidade , Balão Intra-Aórtico/mortalidade , Masculino , Feminino , Pessoa de Meia-Idade , Listas de Espera/mortalidade , Taxa de Sobrevida , Seguimentos , Fatores de Risco , Adulto , Prognóstico , Estudos Retrospectivos , Doadores de Tecidos/provisão & distribuição , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/mortalidade , Coração Auxiliar , Complicações Pós-Operatórias/mortalidade
3.
Annu Rev Med ; 73: 423-438, 2022 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-34554827

RESUMO

The field of endoscopic bariatric and metabolic therapy has rapidly evolved from offering endoscopic treatment of weight regain following bariatric surgery to providing primary weight loss options as alternatives to pharmacologic and surgical interventions. Gastric devices and remodeling procedures were initially designed to work through a mechanism of volume restriction, leading to earlier satiety and reduced caloric intake. As the field continues to grow, small bowel interventions are evolving that may have some effect on weight loss but focus on the treatment of obesity-related comorbidities. Future implementation of combination therapy that utilizes both gastric and small bowel interventions offers an exciting option to further augment weight loss and alleviate metabolic disease. This review considers gastric devices and techniques including space-occupying intragastric balloons, aspiration therapy, endoscopic tissue suturing, and plication interventions, followed by a review of small bowel interventions including endoluminal bypass liners, duodenal mucosal resurfacing, and endoscopically delivered devices to create incisionless anastomoses.


Assuntos
Cirurgia Bariátrica , Manejo da Obesidade , Cirurgia Bariátrica/métodos , Endoscopia/métodos , Humanos , Obesidade/cirurgia , Resultado do Tratamento , Redução de Peso
4.
Am J Physiol Heart Circ Physiol ; 326(3): H812-H820, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38276950

RESUMO

Our study aimed to elucidate the role of different shunts and provide novel insights into optimal treatment approaches for complete transposition of the great arteries (TGA), which is characterized by unique and complicated circulatory dynamics. We constructed a computational cardiovascular TGA model and manipulated cardiovascular parameters, such as atrial septal defect (ASD) and patent ductus arteriosus (PDA) sizes, to quantify their effects on oxygenation and hemodynamics. In addition, ASD flow patterns were investigated as innovative indications for balloon atrial septostomy (BAS). Our model of TGA with an intact ventricular septum (TGA-IVS) showed that a large ASD can achieve sufficient mixing for survival without PDA, and the presence of PDA is detrimental to oxygen delivery. A treatment strategy for TGA-IVS that enlarges the ASD as much as possible by BAS and PDA closure would be desirable. In TGA with a ventricular septal defect (TGA-VSD), the VSD allows for higher oxygenation and reduces the detrimental effects of PDA on systemic circulation. In TGA-VSD, both strategies of enlarging the ASD by BAS with a closed PDA and adjusting the PDA in response to pulmonary vascular resistance (PVR) reduction without BAS may be effective. The simulated ASD flow patterns showed that the sharp peak left-to-right flow pattern in systole (σ-wave) reflected the hemodynamically significant ASD size, independent of PDA, VSD, and PVR. The ASD flow pattern visualized by Doppler echocardiography provides clinical insights into the significance of an ASD and indications for BAS, which are not readily apparent through morphological assessment.NEW & NOTEWORTHY Complete transposition of the great arteries (TGA) represents complex and unique circulation that is dependent on blood mixing through multiple interacting shunts. Consequently, the role of each shunt and the treatment strategy remain unclear. We developed a mathematical model of TGA circulation, revealing the significant influence of atrial septal defect (ASD) on oxygenation and hemodynamics. The blood flow pattern through the ASD reflects its hemodynamic impact and helps determine treatment strategies.


Assuntos
Comunicação Interatrial , Comunicação Interventricular , Transposição dos Grandes Vasos , Humanos , Transposição dos Grandes Vasos/diagnóstico por imagem , Transposição dos Grandes Vasos/cirurgia , Hemodinâmica , Artérias
5.
Cardiovasc Diabetol ; 23(1): 52, 2024 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-38310281

RESUMO

BACKGROUND: The outcomes of percutaneous coronary intervention (PCI) in diabetic patients are still suboptimal, and it is unclear if diabetic patients might derive a benefit from the use of drug-coated balloons. AIMS: To evaluate the impact of diabetes mellitus on the outcomes of patients undergoing PCI with sirolimus-coated balloon (SCB) MagicTouch (Concept Medical, India). METHODS: We conducted a subgroup analysis of the prospective, multicenter, investigator-initiated EASTBOURNE registry, evaluating the performance of MagicTouch SCB in patients with and without diabetes. The study primary endpoint was target lesion revascularization (TLR) at 12-month follow-up. Secondary clinical endpoints were major adverse clinical events (MACE), death, myocardial infarction (MI), and BARC 2-5 bleedings. RESULTS: Among 2,083 enrolled patients, a total of 864 suffered from diabetes (41.5%). Patients with diabetes had a numerically higher occurrence of TLR (6.5% vs. 4.7% HR 1.38, 95%CI 0.91-2.08), all-cause death (3.8% vs. 2.6%, HR 1.81, 95%CI 0.95-3.46), and MACE (12.2% vs. 8.9%; HR 1.26 95%CI 0.92-1.74). The incidence of spontaneous MI was significantly higher among diabetic patients (3.4% vs. 1.5%, HR 2.15 95%CI 1.09-4.25); bleeding events did not significantly differ. The overall incidence of TLR was higher among in-stent restenosis (ISR) as compared to de-novo coronary lesions, irrespectively from diabetes status. CONCLUSIONS: In the EASTBOURNE DIABETES registry, diabetic patients treated with the MagicTouch SCB did not have a significant increase in TLR when compared to non-diabetic patients; moreover, diabetic status did not affect the study device performance in terms of TLR, in both de-novo lesions and ISR.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Diabetes Mellitus , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Sirolimo/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/induzido quimicamente , Sistema de Registros , Reestenose Coronária/epidemiologia , Reestenose Coronária/etiologia
6.
J Vasc Surg ; 79(4): 875-886.e8, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38070783

RESUMO

OBJECTIVE: Analysis of regional data from the Vascular Quality Initiative (VQI) suggested improved survival for patients undergoing stent placement compared with balloon angioplasty and atherectomy. Using national data from the VQI linked to Medicare claims data through the Vascular Implant Surveillance and Interventional Outcomes Network program, this study aimed to compare the rates of mortality, reintervention, and amputation after endovascular interventions (atherectomy, stenting, and balloon angioplasty) for two separate cohorts: patients with chronic limb-threatening ischemia (CLTI) and patients with claudication. METHODS: This was a secondary data analysis of Society for Vascular Surgery National VQI data linked to Medicare claims, between October 2016 and December 2019. Patients aged ≥65 years with symptoms of claudication or CLTI and a diagnosis of occlusive disease were included. Urgent or emergent interventions or those with concurrent procedures (endarterectomy, bypass, or bilateral intervention) were excluded. Interventions were grouped into (1) balloon angioplasty only; (2) stent (with or without balloon angioplasty); or (3) atherectomy (alone, with or without stent, with or without balloon angioplasty). Propensity score-matched cohorts were constructed to conduct pairwise intervention comparisons of mortality, reintervention, and amputation rates. Multivariable logistic regression was used to derive propensity scores for each patient. Kaplan-Meier estimates and Cox proportional hazards ratios (HRs) (95% confidence interval [CI]) analyses were performed. RESULTS: A total of 9785 (2665 claudication, 7120 CLTI) eligible patients were identified. After propensity score matching for the CLTI group, 2826, 3608, and 2796 pairs of cases were used to compare balloon angioplasty vs atherectomy, balloon angioplasty vs stent, and stent vs atherectomy, respectively. No statistically significant difference in mortality was observed among all interventions. However, atherectomy was associated with a significant increase in reintervention rate compared with balloon angioplasty (HR, 1.22; 95% CI, 1.06-1.39; P = .01) and compared with stenting (HR, 1.27; 95% CI, 1.10-1.46; P < .01) within the first year after the index procedure. Of note, both atherectomy (HR, 0.82; 95% CI, 0.68-0.98; P < .05) and stenting (HR, 0.76; 95% CI, 0.64-0.90; P < .01) showed lower rates of major amputation when compared with balloon angioplasty within 1 year after the index procedure. In the claudication group, there were no significant differences observed among interventions for peripheral arterial disease for mortality, reintervention, or amputation rates. CONCLUSIONS: Further studies are needed to identify appropriate indications for atherectomy, because there may be a subset of patients with CLTI who benefit from this therapy with respect to amputation rates. Until then, caution should be exercised when using atherectomy because it is also associated with higher reintervention rates.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Humanos , Idoso , Estados Unidos , Isquemia Crônica Crítica de Membro , Medicare , Fatores de Risco , Isquemia/diagnóstico por imagem , Isquemia/cirurgia , Resultado do Tratamento , Claudicação Intermitente/diagnóstico por imagem , Claudicação Intermitente/cirurgia , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/cirurgia , Angioplastia com Balão/efeitos adversos , Estudos Retrospectivos , Salvamento de Membro
7.
J Vasc Surg ; 79(5): 1110-1118, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38160989

RESUMO

OBJECTIVE: Restenosis after transcarotid artery revascularization (TCAR) is a known complication. When identified in the early postoperative period, it may be related to technique. We evaluated our TCAR experience to identify potentially modifiable factors impacting restenosis. METHODS: This is a single-institution, retrospective review of patients undergoing TCAR from November 2017 to July 2022. Restenosis was defined as >50% stenosis on duplex ultrasound (DUS) examination or computed tomographic angiography (CTA). Continuous variables were compared using Kruskal-Wallis's test. Categorical variables were compared using the Fisher's exact test. RESULTS: Of 61 interventions, 11 (18%) developed restenosis within the median follow-up of 345 days (interquartile range, 103-623 days). Among these patients, 82% (9/11) had >50% stenosis, and 18% (2/11) had >80% stenosis. Both patients with high-grade restenosis were symptomatic and underwent revascularization. Diagnosis of post-TCAR restenosis was via DUS examination in 45% (5/11), CTA in 18% (2/11), or both CTA/DUS examination in 36% (4/11). Restenosis occurred within 1 month in 54% (6/11) and 6 months in 72% (8/11) of patients. However, three of the six patients with restenosis within 1 month had discordant findings on CTA vs DUS imaging. Patient comorbidities, degree of preoperative stenosis, medical management, balloon size, stent size, lesion characteristics, and predilatation angioplasty did not differ. Patients with restenosis were younger (P = .02), had prior ipsilateral endarterectomy (odds ratio [OR], 6.5; P = .02), had history of neck radiation (OR, 18.3; P = .01), and lower rate of postdilatation angioplasty (OR, 0.11; P = .04), without an increased risk of neurological events. CONCLUSIONS: Although post-TCAR restenosis occurred in 18% of patients, only 3% of patients had critical restenosis and required reintervention. Patient factors associated with restenosis were younger age, prior endarterectomy, and history of neck radiation. Although early restenosis may be mitigated by improved technique, the only technical factor associated with restenosis was less use of postdilatation angioplasty. Balancing neurological risk, this factor may have increased application in appropriate patients. Diagnosis of restenosis was inconsistent between imaging modalities; current surveillance paradigms and diagnostic thresholds may warrant reconsideration.


Assuntos
Estenose das Carótidas , Acidente Vascular Cerebral , Humanos , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Constrição Patológica/complicações , Resultado do Tratamento , Fatores de Risco , Artérias , Estudos Retrospectivos , Stents/efeitos adversos , Acidente Vascular Cerebral/etiologia , Medição de Risco
8.
Cancer Invest ; 42(2): 119-140, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38404236

RESUMO

Common detection methods in practice for diagnosing colorectal cancer (CRC) are painful and invasive leading to less participation of individuals for CRC diagnosis. Whereas, improved or enhanced imaging systems and other minimally invasive techniques with shorter detection times deliver greater detail and less discomfort in individuals. Thus, this review is a summary of the diagnostic tests, ranging from the simple potential use in developing a flexible CRC treatment to the patient's potential benefits in receiving less invasive procedures and the advanced treatments that might provide a better assessment for the diagnosis of CRC and reduce the mortality related to CRC.


Assuntos
Neoplasias Colorretais , Humanos , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Colonoscopia
9.
Respir Res ; 25(1): 164, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622598

RESUMO

BACKGROUND: Balloon pulmonary angioplasty (BPA) improves the prognosis of chronic thromboembolic pulmonary hypertension (CTEPH). Right ventricle (RV) is an important predictor of prognosis in CTEPH patients. 2D-speckle tracking echocardiography (2D-STE) can evaluate RV function. This study aimed to evaluate the effectiveness of BPA in CTEPH patients and to assess the value of 2D-STE in predicting outcomes of BPA. METHODS: A total of 76 patients with CTEPH underwent 354 BPA sessions from January 2017 to October 2022. Responders were defined as those with mean pulmonary artery pressure (mPAP) ≤ 30 mmHg or those showing ≥ 30% decrease in pulmonary vascular resistance (PVR) after the last BPA session, compared to baseline. Logistic regression analysis was performed to identify predictors of BPA efficacy. RESULTS: BPA resulted in a significant decrease in mPAP (from 50.8 ± 10.4 mmHg to 35.5 ± 11.9 mmHg, p < 0.001), PVR (from 888.7 ± 363.5 dyn·s·cm-5 to 545.5 ± 383.8 dyn·s·cm-5, p < 0.001), and eccentricity index (from 1.3 to 1.1, p < 0.001), and a significant increase in RV free wall longitudinal strain (RVFWLS: from 15.7% to 21.0%, p < 0.001). Significant improvement was also observed in the 6-min walking distance (from 385.5 m to 454.5 m, p < 0.001). After adjusting for confounders, multivariate analysis showed that RVFWLS was the only independent predictor of BPA efficacy. The optimal RVFWLS cutoff value for predicting BPA responders was 12%. CONCLUSIONS: BPA was found to reduce pulmonary artery pressure, reverse RV remodeling, and improve exercise capacity. RVFWLS obtained by 2D-STE was an independent predictor of BPA outcomes. Our study may provide a meaningful reference for interventional therapy of CTEPH.


Assuntos
Angioplastia com Balão , Hipertensão Pulmonar , Embolia Pulmonar , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/terapia , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/terapia , Remodelação Ventricular , Ecocardiografia , Doença Crônica , Artéria Pulmonar/diagnóstico por imagem
10.
Reprod Biol Endocrinol ; 22(1): 49, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654308

RESUMO

STUDY OBJECTIVE: To evaluate the efficacy and pregnancy outcomes of intrauterine balloon and intrauterine contraceptive devices in the prevention of adhesion reformation following hysteroscopic adhesiolysis in infertile women with moderate to severe intrauterine adhesion. DESIGN: A prospective, randomized, controlled trial study. SETTING: A tertiary university hospital. PATIENTS: A total of 130 patients with moderate (American Fertility Society [AFS] score of 5-8) and severe (AFS score of 9-12) intrauterine adhesions were recruited. INTERVENTIONS: 86 patients were evenly allocated to group treated with an IUD for 1 month and group treated with an IUD for 2 months. 44 patients were allocated to group treated with a Foley catheter balloon.(IUD: Yuangong IUD). MEASUREMENTS AND MAIN RESULTS: The primary outcome measures were the AFS score, endometrial thickness, and pregnancy outcome. After hysteroscopy, the AFS score was significantly decreased(P<0.05), whereas endometrial thickness was significantly increased across the three groups(P<0.001). Notably, the decline in the AFS score in the balloon group was greater than that in the IUD-1-month group and IUD-2-month group(P<0.01), with no significant difference between the IUD groups(P = 0.298). Lastly, In addition, the extent of the increase in endometrial thickness(P = 0.502) and the pregnancy outcomes(P = 0.803) in the three groups were not significantly different. CONCLUSION: Inserting a balloon or placing an IUD for one or two months can effectively lower the risk of adhesion recurrence and restore the shape of the uterine cavity. While the therapeutic effect of the balloon was superior to that of the IUD, no significant differences were observed in the one-month and two-month IUD groups. TRIAL REGISTRATION: This research was registered in the Chinese Clinical Trial Registry ( http://www.chictr.org.cn/enIndex.aspx ); Clinical trial registry identification number: ChiCTR-IOR-17,011,943 ( http://www.chictr.org.cn/showprojen.aspx?proj=17979 ). Date of trial registration: July 11, 2017.


Assuntos
Histeroscopia , Infertilidade Feminina , Dispositivos Intrauterinos , Resultado da Gravidez , Humanos , Feminino , Aderências Teciduais/prevenção & controle , Adulto , Gravidez , Histeroscopia/métodos , Infertilidade Feminina/terapia , Infertilidade Feminina/etiologia , Infertilidade Feminina/prevenção & controle , Estudos Prospectivos , Doenças Uterinas/cirurgia , Doenças Uterinas/complicações , Doenças Uterinas/prevenção & controle , Doenças Uterinas/patologia , Resultado do Tratamento , Taxa de Gravidez
11.
Transfusion ; 64 Suppl 2: S19-S26, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38581267

RESUMO

BACKGROUND: Resuscitative endovascular balloon occlusion of the aorta (REBOA) has been often used in place of open aortic occlusion for management of hemorrhagic shock in trauma. There is a paucity of data evaluating REBOA usage in military settings. STUDY DESIGN AND METHODS: We queried the Department of Defense Trauma Registry (DODTR) for all cases with at least one intervention or assessment available within the first 72 h after injury between 2007 and 2023. We used relevant procedural codes to identify the use of REBOA within the DODTR, and we used descriptive statistics to characterize its use. RESULTS: We identified 17 cases of REBOA placed in combat settings from 2017 to 2019. The majority of these were placed in the operating room (76%) and in civilian patients (70%). A penetrating mechanism caused the injury in 94% of cases with predominantly the abdomen and extremities having serious injuries. All patients subsequently underwent an exploratory laparotomy after REBOA placement, with moderate numbers of patients having spleen, liver, and small bowel injuries. The majority (82%) of included patients survived to hospital discharge. DISCUSSION: We describe 17 cases of REBOA within the DODTR from 2007 to 2023, adding to the limited documentation of patients undergoing REBOA in military settings. We identified patterns of injury in line with previous studies of patients undergoing REBOA in military settings. In this small sample of military casualties, we observed a high survival rate.


Assuntos
Aorta , Oclusão com Balão , Procedimentos Endovasculares , Ressuscitação , Choque Hemorrágico , Humanos , Oclusão com Balão/métodos , Ressuscitação/métodos , Masculino , Adulto , Feminino , Choque Hemorrágico/terapia , Choque Hemorrágico/etiologia , Procedimentos Endovasculares/métodos , Sistema de Registros , Militares
12.
Cell Commun Signal ; 22(1): 334, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38890646

RESUMO

INTRODUCTION: Balloon flower root-derived exosome-like nanoparticles (BDEs) have recently been proposed as physiologically active molecules with no cytotoxicity. However, the therapeutic effects of drug-induced hepatotoxicity of BDEs have not been elucidated. BDEs contain a large amount of platycodin D, which is widely known to be effective in regulating inflammation and ameliorating systemic toxicity. Thus, the main therapeutic activity of BDEs is attributed to inhibiting the inflammatory response and alleviating toxicity. In this study, we fabricated the hybrid BDEs fused with liposomes containing silymarin (SM) to enhance the synergistic effect on inhibition of acetaminophen-induced hepatotoxicity (APAP). OBJECTIVE: Considering the potential therapeutic effects of BDEs, and the potential to achieve synergistic effects to improve therapeutic outcomes, we constructed hybrid BDEs with a soy lecithin-based liposome loaded with SM. Since liposomes can provide higher thermal stability and have greater structural integrity, these might be more resistant to clearance and enzymatic degradation of drug molecules. METHODS: Hybrid BDEs with liposome-loaded SM (BDEs@lipo-SM) were fabricated by thin-film hydration and extrusion. BDEs@lipo-SM were characterized using dynamic light scattering and high-performance liquid chromatography. After confirmation of the physical properties of BDEs@lipo-SM, various therapeutic properties were evaluated. RESULTS: BDEs@lipo-SM were internalized by hepatocytes and immune cells and significantly decreased mRNA expression of apoptosis and inflammation-relevant cytokines by inhibiting the hepatocyte MAPK pathway. BDEs@lipo-SM significantly induced an increase in glutathione levels and inhibited APAP-induced hepatotoxicity. CONCLUSION: From this study, we know that BDEs are reliable and safe nanovesicles containing natural metabolites derived from balloon flower, and they can facilitate intercellular communication. BDEs are also easily modified to enhance drug loading capacity, targeting effects, and long-term accumulation in vivo. BDEs@lipo-SM have therapeutic benefits for acute liver injury and can alleviate cell death and toxicity. They can be efficiently delivered to the liver and effectively inhibit APAP-induced hepatotoxicity by inhibiting the MAPK signaling pathway and apoptosis, which accelerates liver recovery in the APAP-induced acute liver injury model. These findings highlight that BDEs represent an attractive delivery vehicle for drug delivery.


Assuntos
Acetaminofen , Apoptose , Exossomos , Hepatócitos , Sistema de Sinalização das MAP Quinases , Nanopartículas , Silimarina , Apoptose/efeitos dos fármacos , Animais , Nanopartículas/química , Exossomos/metabolismo , Hepatócitos/efeitos dos fármacos , Hepatócitos/metabolismo , Silimarina/farmacologia , Silimarina/administração & dosagem , Sistema de Sinalização das MAP Quinases/efeitos dos fármacos , Camundongos , Doença Hepática Induzida por Substâncias e Drogas/tratamento farmacológico , Doença Hepática Induzida por Substâncias e Drogas/metabolismo , Humanos , Lipossomos/química , Masculino , Raízes de Plantas , Camundongos Endogâmicos C57BL
13.
Artigo em Inglês | MEDLINE | ID: mdl-39044661

RESUMO

BACKGROUND: Although use of sirolimus-based analogs has shown superiority over paclitaxel in drug-eluting stents, the relative efficacy of these two agents released from drug-coated balloons (DCB) is unclear. The present meta-analysis is aimed to compare outcomes after percutaneous coronary intervention (PCI) with paclitaxel-coated balloons (PCB) versus sirolimus-coated balloons (SCB) for either in-stent restenosis or native de novo lesions. METHODS: The study outcomes were 1) target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, or target lesion revascularization, and 2) follow-up angiographic parameters including late lumen loss (LLL), diameter stenosis, and minimal lumen diameter (MLD). Pooled odds ratios (OR) and weighted mean differences (WMD) with 95% confidence intervals (CI) were calculated by using random-effects models. RESULTS: A search of PubMed, EMBASE, and Cochrane Library from their inception to January 2024 identified five randomized clinical trials and three observational studies with a total of 1861 patients (889 in PCB and 972 in SCB groups). During 9-12 months of follow-up, there was no significant difference in TLF (OR 1.01, 95% CI 0.75-1.35) between the two groups. On follow-up angiography at 6-9 months, MLD (WMD 0.10, 95% CI 0.02-0.17) was larger in PCB but there was no statistically significant difference in LLL (WMD -0.11, 95% CI -0.23-0.02) and diameter stenosis (WMD -3.33, 95% CI -8.11-1.45). CONCLUSIONS: Among patients undergoing DCB-only PCI, the risk of TLF was similar during 9-12 months of follow-up after PCB and SCB treatment. However, the MLD was larger favoring PCB over SCB on follow-up angiography.

14.
Artigo em Inglês | MEDLINE | ID: mdl-38984673

RESUMO

BACKGROUND: Debulking devices are often followed by a scoring or cutting balloon in percutaneous coronary intervention (PCI) for severely calcified lesions. However, there are limited data on balloon preparation after orbital atherectomy (OA) assessed using optical coherence tomography (OCT). AIM: We aimed to compare the effects of a novel scoring and cutting balloon on calcified coronary lesions with OCT. METHODS: We retrospectively examined 38 patients (38 lesions) who underwent PCI with a scoring or a cutting balloon after OA. All patients underwent pre-PCI, preballooning, postballooning, and post-PCI OCT imaging. We divided the patients into novel scoring-balloon (group A: n = 22) and cutting-balloon (group B: n = 16) groups and compared the OCT findings, including minimum lumen area (MLA) and expansion ratio (MLA divided by mean reference lumen area). RESULTS: The mean patient age was 76.1 ± 8.7 years; 71.5% were male. There were no significant differences in patient background between both groups. Regarding procedural characteristics, the maximum balloon pressure was significantly higher in group A (median 23 atm, interquartile range [IQR] 18-24 vs. 12 atm [IQR: 10-12], p < 0.01). Although a calcium score of 4 was more frequently observed in group A (86.4% vs. 62.5%, p = 0.12), post-PCI MLA was comparable between both groups (3.95 mm2 [IQR: 3.27-4.41] vs. 3.43 mm2 [IQR: 2.90-4.82], p = 0.63). Furthermore, the expansion ratio was significantly greater in group A (0.83 ± 0.20 vs. 0.68 ± 0.14, p < 0.01). CONCLUSION: Despite a higher calcium score, a larger expansion ratio was achieved in patients with a novel scoring balloon than in those with a cutting balloon after OA.

15.
Catheter Cardiovasc Interv ; 103(1): 209-218, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37957842

RESUMO

BACKGROUND: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown. AIMS: To evaluate the impact of BPD on valve durability and long-term clinical outcomes in patients undergoing self-expanding transcatheter valve implantation (TAVI). METHODS: Echocardiographic and clinical data from the ClinicalService (a nation-based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all-cause death and SVD. Cumulative incidence functions for SVD were estimated. RESULTS: Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6-year follow-up were found between groups in terms of all-cause mortality (HR: 1.05, 95% CI: 0.9-1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6-year follow-up. CONCLUSIONS: BPD following TAVI with a self-expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6-year follow-up.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Dilatação , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Desenho de Prótese
16.
Catheter Cardiovasc Interv ; 103(1): 115-118, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37994384

RESUMO

We present the case of a 28-year-old woman with a history of tricuspid valve endocarditis leading to chronic thromboembolic pulmonary hypertension (CTEPH) with multiple pulmonary artery chronic total occlusions (CTOs) due to septic emboli. Following a multidisciplinary care discussion, the patient was brought forward for balloon pulmonary angioplasty (BPA) with successful revascularization of all chronically occluded territories. This case highlights advances in pulmonary artery CTO interventions and demonstrates the feasibility of BPA for CTEPH patients with a history of septic emboli.


Assuntos
Angioplastia com Balão , Hipertensão Pulmonar , Embolia Pulmonar , Feminino , Humanos , Adulto , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/terapia , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Resultado do Tratamento , Doença Crônica , Artéria Pulmonar
17.
Catheter Cardiovasc Interv ; 104(1): 105-114, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38819623

RESUMO

BACKGROUND: The anatomic substrate of bicuspid valves may lead to suboptimal TAVR stent expansion and geometry. AIM: We evaluated determinants of stent geometry in bicuspid valves treated with Sapien transcatheter aortic valve replacement (TAVR) valves. METHODS: A multicenter retrospective registry of patients (February 2019 to August 2022) who underwent post-TAVR computed tomography to determine stent area (vs. nominal valve area) and stent ellipticity (maximum diameter/minimum diameter). Predictors of relative stent expansion (minimum area/average of inflow + outflow area) and stent ellipticity were evaluated in a multivariable regression model, including valve calcium volume (indexed by annular area), presence of raphe calcium, sinus diameters indexed by area-derived annular diameter, and performance of pre-dilation and post-dilation. RESULTS: The registry enrolled 101 patients from four centers. The minimum stent area (vs. nominal area) was 88.1%, and the maximum ellipticity was 1.10, with both observed near the midframe of the valve in all cases. Relative stent expansion ≥90% was observed in 64/101 patients. The only significant predictor of relative stent expansion ≥90% was the performance of post-dilation (OR: 4.79, p = 0.018). Relative stent expansion ≥90% was seen in 86% of patients with post-dilation compared to 57% without (p < 0.001). The stent ellipticity ≥1.1 was observed in 47/101 patients. The significant predictors of stent ellipticity ≥1.1 were the indexed maximum sinus diameter (OR: 0.582, p = 0.021) and indexed intercommisural diameter at 4 mm (OR: 2.42, p = 0.001). Stent expansion has a weak negative correlation with post-TAVR mean gradient (r = -0.324, p < 0.001). CONCLUSION: Relative stent expansion ≥90% was associated with the performance of post-dilation, and stent ellipticity ≥1.1 was associated with indexed intercommisural diameter and indexed maximum sinus diameter. Further studies to determine optimal deployment strategies in bicuspid valves are needed.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Feminino , Masculino , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Idoso , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/cirurgia , Valvuloplastia com Balão/efeitos adversos , Fatores de Risco , Estados Unidos , Stents
18.
Catheter Cardiovasc Interv ; 103(3): 404-416, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38214114

RESUMO

BACKGROUND: Some clinical trials have verified the efficacy and safety of paclitaxel drug-coated balloon (DCB) for small vessel coronary artery disease. However, nonsmall vessel and calcified lesions received less attention. AIMS: This study aimed to investigate the efficacy of DCB treatment for various types of coronary artery lesions, including not only small vessel disease but also nonsmall vessel disease and calcified lesions. In this real-world clinical practice study, in-stent restenosis was excluded. METHODS: This study consecutively included 934 patients with 1751 nonstented lesions who received DCB at a cardiovascular center in Kyoto Katsura Hospital in Japan between 2009 and 2012 and 2014 to 2019. This study enrolled and retrospectively analyzed all of the patients. Eligible patients routinely underwent follow-up angiography at 6-8 months after percutaneous coronary intervention. The primary endpoint includes target lesion revascularization (TLR) during follow-up. Further, this study calculated the predictor of TLR using multivariate analysis. RESULTS: This study included the lesions involving 46.4% of type B2/C, 26.9% with severe calcification, and 6.0% with DCB restenosis. Mean DCB diameter and length were 2.75 ± 0.51 mm and 24.2 ± 9.6 mm, respectively. The median follow-up duration was 18 months. Follow-up angiography revealed a TLR rate of 9% and a restenosis rate of 9%. This study identified hemodialysis and current smoking as independent TLR predictors. CONCLUSION: In routine clinical practice, the effectiveness of DCB was observed consistently across various types of coronary artery disease.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Estudos Retrospectivos , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Paclitaxel/efeitos adversos , Constrição Patológica , Materiais Revestidos Biocompatíveis , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Angiografia Coronária
19.
Artigo em Inglês | MEDLINE | ID: mdl-38841916

RESUMO

BACKGROUND: Residual transprosthetic gradient (TG) after transcatheter aortic valve replacement (TAVR) with balloon-expandable valves (BEV) may be due to suboptimal valve expansion. AIMS: To compare hemodynamics after TAVR with small BEV according to postdilation strategy. METHODS: This observational, retrospective cohort study included 184 consecutive patients from a single center treated with 23 mm Sapien 3 Ultra (Edwards Lifesciences) BEV implantation in the aortic position and enrolled between January 2020 and April 2023. Patients treated with routine postdilation (RP, n = 73) were compared to patients treated according to local standard practice (SP, n = 111). Primary endpoint was 30-day mean TG. Secondary endpoints were incidence of 30-day prosthesis-patient mismatch (PPM), technical success and device success. RESULTS: Thirty-day mean TG was lower in RP versus SP (12.3 ± 4.6 mmHg vs. 14.1 ± 5.7 mmHg, p = 0.031), and incidence of PPM was less common with RP versus SP (47.3% vs. 71.0%, p = 0.006). Technical success (98.6% vs. 99.1%, p = 0.637) and device success (93.1% vs. 90.1%, p = 0.330) did not differ between groups. Differences in 30-day mean TG were driven by patients at normal flow (12.1 ± 4.0 mmHg vs. 15.0 ± 5.5 mmHg, p = 0.014), while no differences were evident among patients at low flow (12.5 ± 5.5 mmHg vs. 11.7 ± 5.5 mmHg, p = 0.644). RP decreased height and increased width of BEV, and a linear regression established that final BEV width could predict 30-day mean TG (r = -0.6654, p < 0.0001). CONCLUSIONS: RP after TAVR with small BEV was associated with more favorable forward-flow hemodynamics than SP.

20.
Artigo em Inglês | MEDLINE | ID: mdl-38922752

RESUMO

As the general population ages, the incidence of degenerative mitral stenosis (MS) among patients has increased. Percutaneous mitral valvuloplasty (PMV) has emerged as a well-established option for mitral rheumatic stenosis with specific characteristics. However, a blank therapeutic space must be filled with the treatment options for degenerative or rheumatic mitral stenosis in patients with many comorbidities and contraindication for valvuloplasty. We here present a comprehensive overview of the current possibilities, despite their scarce success. That is the reason why we propose a case series to facilitate a better understanding of our innovative technique in this challenging clinical context.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA