Electromagn Biol Med ; 43(1-2): 125-134, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38533761

RESUMO

The present study analyzed the microwave ablation of cancerous tumors located in six major cancer-prone organs and estimated the significance of input power and treatment time parameters in the apt positioning of the trocar into the tissue during microwave ablation. The present study has considered a three-dimensional two-compartment tumour-embedded tissue model. FEA based COMSOL Multiphysics software with inbuilt bioheat transfer, electromagnetic waves, heat transfer in solids and fluids, and laminar flow physics has been used to obtain the numerical results. Based on the mortality rates caused by cancer, the present study has considered six major organs affected by cancer, viz. lung, breast, stomach/gastric, liver, liver (with colon metastasis), and kidney for MWA analysis. The input power (100 W) and ablation times (4 minutes) with apt and inapt positioning of the trocar have been considered to compare the ablation volume of various cancerous tissues. The present study addresses one of the major problems clinicians face, i.e. the proper placement of the trocar due to poor imaging techniques and human error, resulting in incomplete tumor ablation and increased surgical procedures. The highest values of the ablation region have been observed for the liver, colon metastatic liver and breast cancerous tissues compared with other organs at the same operating conditions.


The present study has investigated the application of microwave ablation for cancer treatment in six major organs, specifically emphasizing the evaluation of ablation volume during the procedure. Using COMSOL-Multiphysics software, the study has investigated MWA of tumor embedded organs in the lung, breast, stomach, liver, and kidney. The positioning of the trocar, a crucial element in the treatment process, has been examined to address challenges in effectively ablating tumors.From the results, it has been revealed that liver, colon metastatic liver, and breast cancer tissues exhibited the largest areas of ablation volume compared with other organs.Organs like the breast and hepatic glands, characterized by lower heat capacity and density, have shown larger ablation zones. Trocar positioning significantly influenced the stomach, liver, and kidney, where improper placement led to notable increases in ablation volume, posing a risk of unintended damage to healthy tissue.Further, the study has concluded that precise trocar positioning plays a crucial role in optimizing microwave ablation. This precision has the potential to enhance the effectiveness of cancer treatments while minimizing harm to healthy tissue. The insights gained from this research offer valuable information for clinicians looking to enhance the precision of cancer therapies, ultimately aiming for improved outcomes for patients.


Assuntos
Técnicas de Ablação , Micro-Ondas , Neoplasias , Humanos , Técnicas de Ablação/instrumentação , Neoplasias/patologia , Neoplasias/cirurgia , Instrumentos Cirúrgicos , Análise de Elementos Finitos , Modelos Biológicos
2.
Sensors (Basel) ; 23(11)2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37299756

RESUMO

This research article proposes and numerically investigates a photonic crystal fiber (PCF) based on a surface plasmon resonance (SPR) sensor for the detecting refractive index (RI) of unknown analytes. The plasmonic material (gold) layer is placed outside of the PCF by removing two air holes from the main structure, and a D-shaped PCF-SPR sensor is formed. The purpose of using a plasmonic material (gold) layer in a PCF structure is to introduce an SPR phenomenon. The structure of the PCF is likely enclosed by the analyte to be detected, and an external sensing system is used to measure changes in the SPR signal. Moreover, a perfectly matched layer (PML) is also placed outside of the PCF to absorb unwanted light signals towards the surface. The numerical investigation of all guiding properties of the PCF-SPR sensor is completed using a fully vectorial-based finite element method (FEM) to achieve the finest sensing performance. The design of the PCF-SPR sensor is completed using COMSOL Multiphysics software, version 1.4.50. According to the simulation results, the proposed PCF-SPR sensor has a maximum wavelength sensitivity of 9000 nm/RIU, an amplitude sensitivity of 3746 RIU-1, a sensor resolution of 1 × 10-5 RIU, and a figure of merit (FOM) of 900 RIU-1 in the x-polarized direction light signal. The miniaturized structure and high sensitivity of the proposed PCF-SPR sensor make it a promising candidate for detecting RI of analytes ranging from 1.28 to 1.42.


Assuntos
Ouro , Ressonância de Plasmônio de Superfície , Simulação por Computador , Fótons , Software
3.
Sensors (Basel) ; 23(9)2023 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-37177548

RESUMO

A grounded coplanar waveguide (GCPW), as a millimeter wave special transmission line, can be used to calibrate broadband oscilloscope probes. A method to change the through-hole structure to widen the GCPW is investigated in this paper. The effect of the through-hole array on the band-width of the GCPW is investigated and verified using COMSOL Multiphysics simulation software. Finally, the S-parameters of the fabricated GCPWs are measured by a vector network analyzer, and the results show that they have an insertion loss > -3 dB and return loss < -10 dB in the frequency range of DC to 60 GHz, which satisfies the design requirements.

4.
Sensors (Basel) ; 23(3)2023 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-36772316

RESUMO

To achieve a wide range and high accuracy detection of the vacuum level, for example, in an encapsulated vacuum microcavity, a composite-type MEMS Pirani gauge has been designed and fabricated. The Pirani gauge consists of two gauges of different sizes connected in series, with one gauge having a larger heat-sensitive area and a larger air gap for extending the lower measurable limit of pressure (i.e., the high vacuum end) and the other gauge having a smaller heat-sensitive area and a smaller air gap for extending the upper measurable limit. The high-resistivity titanium metal was chosen as the thermistor; SiNx was chosen as the dielectric layer, considering the factors relevant to simulation and manufacturing. By simulation using COMSOL Multiphysics and NI Multisim, a range of measurement of 2 × 10-2 to 2 × 105 Pa and a sensitivity of 52.4 mV/lgPa were obtained in an N2 environment. The performance of the fabricated Pirani gauge was evaluated by using an in-house made vacuum test system. In the test, the actual points of measurement range from 6.6 × 10-2 to 1.12 × 105 Pa, and the highest sensitivity is up to 457.6 mV/lgPa. The experimental results are better in the range of measurement, sensitivity, and accuracy than the simulation results. The Pirani gauge proposed in this study is simple in structure, easy to manufacture, and suitable for integration with other MEMS devices in a microcavity to monitor the vacuum level therein.

5.
J Environ Manage ; 346: 118947, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37699289

RESUMO

Combined remediation technologies are increasingly being considered to uranium contaminated groundwater, such as the joint utilize of permeable reactive bio-barrier (Bio-PRB) and electrokinetic remediation (EKR). While the assessment of uranium plume evolution in the combined remediation system (CRS) have often been impeded by insufficient understanding of multi-physical field superposition. Therefore, advanced knowledge in multi-physical field coupling in groundwater flow will be crucial to the practical application of these techniques. A two-dimensional multi-physical field coupling model was constructed for predicting the uranium degradation in CRS. The study demonstrates that the coupling model is able to predict the uranium plume evolution and rapidly evaluate the performance of CRS components. The results show that field electric direction and flow field strength are the key factors that affect the retardation and remediation performance of CRS. The reverse electric field direction significantly affected the contact reaction time of uranium in the system. The uranium residence time in the reverse electric field was 3.8 d, which was significantly greater than the original electric field (2.0 d). Depending on the voltage, the reverse electric field direction was 16%-36% more efficient than the original direction. The strength of the flow field was about two orders of magnitude higher than that of the electric field, so the groundwater flow rate dominated remediation efficiency. Reducing the flow rate by 1/2 could improve the performance of the system by approximately 66%. In addition, the coupling model can be utilized to design standard CRS for real site of uranium contaminated groundwater. To meet the optimal performance, the direction of the electric field should be set opposite to the flow field. This work has successfully used a coupling model to predict uranium contaminant-plume evolution in CRS and estimate the performance of each component.

6.
Electrophoresis ; 43(5-6): 741-751, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35019166

RESUMO

We report on the investigation of electropreconcentration phenomena in micro-/nanofluidic devices integrating 100 µm long nanochannels using 2D COMSOL simulations based on the coupled Poisson-Nernst-Planck and Navier-Stokes system of equations. Our numerical model is used to demonstrate the influence of key governing parameters such as electrolyte concentration, surface charge density, and applied axial electric field on ion concentration polarization (ICP) dynamics in our system. Under sufficiently extreme surface-charge-governed transport conditions, ICP propagation is shown to enable various transient and stationary stacking and counter-flow gradient focusing mechanisms of anionic analytes. We resolve these spatiotemporal dynamics of analytes and electrolyte ICP over disparate time and length scales, and confirm previous findings that the greatest enhancement is observed when a system is tuned for analyte focusing at the charge, excluding microchannel, nanochannel electrical double layer (EDL) interface. Moreover, we demonstrate that such tuning can readily be achieved by including additional nanochannels oriented parallel to the electric field between two microchannels, effectively increasing the overall perm-selectivity and leading to enhanced focusing at the EDL interfaces. This approach shows promise in providing added control over the extent of ICP in electrokinetic systems, particularly under circumstances in which relatively weak ICP effects are observed using only a single channel.


Assuntos
Eletricidade , Eletrólitos
7.
J Biomech Eng ; 144(9)2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35237800

RESUMO

This research aimed to examine the impact of a proposed flow stent (PFS) on different abdominal artery shapes. For that purpose, a finite element-based model using the computational fluid dynamics (CFD) method is developed. The effect of PFS intervention on the hemodynamic efficiency is estimated by all of the significant criteria used for the evaluation of aneurysm occlusion and possible rupture; the flow velocity, pressure, wall shear stress (WSS), and WSS-related indices. Results showed that PFS intervention preserves the effects of high flowrate and decreases irregular flow recirculation in the sac of the aneurysm. The flow velocity reduction inside the aneurysm sac is in the range of 55% to 80% and the time-averaged wall shear stress (TAWSS) reduction is in the range of 42% to 53% by PFS deployment. The simulation results implies that PFS could heal an aneurysm efficiently with a mechanism that causes the development of thrombus and ultimately leads to aneurysm resorption.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma Intracraniano , Simulação por Computador , Análise de Elementos Finitos , Hemodinâmica , Humanos , Modelos Cardiovasculares , Stents , Estresse Mecânico
8.
Sensors (Basel) ; 22(17)2022 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-36080808

RESUMO

Body hydration is considered one of the most important physiological parameters to measure and one of the most challenging. Current methods to assess hydration are invasive and require costly clinical settings. The bio-impedance analysis offers a noninvasive and inexpensive tool to assess hydration, and it can be designed to be used in wearable health devices. The use of wearable electronics in healthcare applications has received increased attention over the last decade. New, emerging medical devices feature continuous patient monitoring and data collection to provide suitable treatment and preventive actions. In this paper, a model of human skin is developed and simulated to be used as a guide to designing a dehydration monitoring system based on a bio-impedance analysis technique. The study investigates the effect of applying different frequencies on the dielectric parameters of the skin and the resulting measured impedance. Two different interdigitated electrode designs are presented, and a comparison of the measurements is presented. The rectangular IDE is printed and tested on subjects to validate the bio-impedance method and study the interpretation of its results. The proposed design offers a classification criterion that can be used to assess dehydration without the need for a complex mathematical model. Further clinical testing and data are needed to refine and finalize the criteria.


Assuntos
Desidratação , Dispositivos Eletrônicos Vestíveis , Desidratação/diagnóstico , Impedância Elétrica , Eletrodos , Eletrônica , Humanos
9.
Sensors (Basel) ; 22(6)2022 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-35336470

RESUMO

Lead Zirconate Titanate (PZT) sensors have become popular in structural health monitoring (SHM) using the electromechanical impedance (EMI) technique for damage identification. The vibrations generated during the casting process in concrete structures substantially impact the conductance signature's (real part of admittance) magnitude and sensitivity. The concept of smart sensing units (SSU) is presented, composed of a PZT patch, an adhesive layer, and a steel plate. It is embedded in the concrete structure to study the impact of damage since it has high sensitivity to detect any structural changes, resulting in a high electrical conductance signature. The conductance signatures are obtained from the EMI technique at the damage state in the 10-500 kHz high-frequency range. The wave propagation technique proposes implementing the novel embedded SSUs to detect damage in the host structure. The numerical simulation is carried out with COMSOL multiphysics, and the received voltage signal is compared between the damaged and undamaged concrete beam with the applied actuation signal. A five-cycle sine burst modulated by a Hanning window is employed as the transient excitation signal. For numerical investigation, six cases are explored to better understand how the wave travels when a structural discontinuity is accounted for. The changes in the received signal during actuator-receiver mode in the damage state of the host structure are quantified using time of flight (TOF). Furthermore, the numerical studies are carried out by combining the EMI-WP technique, which implies synchronous activation of EMI-based measurements and wave stimulation. The fundamental idea is to implement EMI-WP to improve the effectiveness of SSU patches in detecting both near-field and far-field damage in structures. One SSU is used as an EMI admittance sensor for local damage identification. Meanwhile, the same EMI admittance sensor is used to acquire elastic waves generated by another SSU to monitor damages outside the EMI admittance sensor's sensing area. Finally, the experimental validation is carried out to verify the proposed methodology. The results show that combining both techniques is an effective SHM method for detecting damage in concrete structures.

10.
Sensors (Basel) ; 22(23)2022 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-36501977

RESUMO

We have designed a hot-plate-type micro-Pirani vacuum gauge with a simple structure and compatibility with conventional semiconductor fabrication processes. In the Pirani gauge, we used a vanadium oxide (VOx) membrane as the thermosensitive component, taking advantage of the high temperature coefficient of resistance (TCR) of VOx. The TCR value of VOx is -2%K-1∼-3%K-1, an order of magnitude higher than those of other thermal-sensitive materials, such as platinum and titanium (0.3%K-1∼0.4%K-1). On one hand, we used the high TCR of VOx to increase the Pirani sensitivity. On the other hand, we optimized the floating structure to decrease the thermal conductivity so that the detecting range of the Pirani gauge was extended on the low-pressure end. We carried out simulation experiments on the thermal zone of the Pirani gauge, the width of the cantilever beam, the material and thickness of the supporting layer, the thickness of the thermal layer (VOx), the depth of the cavity, and the shape and size. Finally, we decided on the basic size of the Pirani gauge. The prepared Pirani gauge has a thermal sensitive area of 130 × 130 µm2, with a cantilever width of 13 µm, cavity depth of 5 µm, supporting layer thickness of 300 nm, and VOx layer thickness of 110 nm. It has a dynamic range of 10-1~104 Pa and a sensitivity of 1.23 V/lgPa. The VOx Pirani was designed using a structure and fabrication process compatible with a VOx-based uncooled infrared microbolometer so that it can be integrated by wafer level. This work contains only our MEMS Pirani gauge device design, preparation process design, and readout circuit design, while the characterization and relevant experimental results will be reported in the future.

11.
Biomed Microdevices ; 23(1): 9, 2021 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-33449205

RESUMO

In this work, an optimized, non-invasive four electrode-based impedimetric sensors have been designed, fabricated, and characterized for measuring the impedance of a biological cell. The impedimetric sensors having four mono-polar electrodes were fabricated utilizing the photolithography technique with gold as the electrode material. Furthermore, the impedance of the electrolyte/electrode interface was simulated by optimizing different parameters, including applied voltage, PBS thickness, and diameter, using COMSOL Multiphysics software for a frequency range of 100 Hz to 1 MHz. Next, the impedance of the fabricated device was measured experimentally using the electrochemical impedance spectroscopy (EIS) technique. Then, the COMSOL data was equated with the impedance obtained from the fabricated devices to realize the feasibility and error percentage (RSE < 5%) of the sensor. The equivalent circuit model for the measured impedance data of PBS was obtained utilizing the ZsimpWin software. Besides, the mathematical relations between the impedance, phase angle and the area of the electrode were interpreted for the fabricated impedimetric sensors. Later on, a real blood sample was also characterized to demonstrate the feasibility and the validity of the proposed technique and the fabricated devices in cell diagnosis.


Assuntos
Espectroscopia Dielétrica , Ouro , Impedância Elétrica , Eletrodos
12.
Biomed Eng Online ; 20(1): 60, 2021 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-34130690

RESUMO

BACKGROUND: Peripheral nerve injury can cause significant impairment, and the current methods for facilitating repair, particularly over distances greater than approximately 1 mm, are not entirely effective. Allografts, autografts, and synthetic conduits are three of the most common surgical interventions for peripheral nerve repair; however, each has limitations including poor biocompatibility, adverse immune responses, and the need for successive surgeries. A potential new method for promoting peripheral nerve repair that addresses the shortcomings of current interventions is a biocompatible cellulose nanofibril (CNF) conduit that degrades in-vivo over time. Preliminary testing in multiple animal models has yielded positive results, but more information is needed regarding how the CNF conduit facilitates nutrient and gas flow. RESULTS: The current work employs 3D modelling and analysis via COMSOL Multiphysics® to determine how the CNF conduit facilitates oxygen movement both radially through the conduit walls and axially along the length of the conduit. Various CNF wall permeabilities, conduit lengths, and nerve-to-conduit diameter ratios have been examined; all of which were shown to have an impact on the resultant oxygen profile within the conduit. When the walls of the CNF conduit were modeled to have significant oxygen permeability, oxygen diffusion across the conduit was shown to dominate relative to axial diffusion of oxygen along the length of the conduit, which was otherwise the controlling diffusion mechanism. CONCLUSIONS: The results of this study suggest that there is a complex relationship between axial and radial diffusion as the properties of the conduit such as length, diameter, and permeability are altered and when investigating various locations within the model. At low wall permeabilities the axial diffusion is dominant for all configurations, while for higher wall permeabilities the radial diffusion became dominant for smaller diameters. The length of the conduit did not alter the mechanism of diffusion, but rather had an inverse relationship with the magnitude of the overall concentration profile. As such the modeling results may be employed to predict and control the amount and distribution of oxygenation throughout the conduit, and hence to guide experimental conduit design.


Assuntos
Traumatismos dos Nervos Periféricos , Celulose , Oxigênio
13.
Sensors (Basel) ; 21(18)2021 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-34577458

RESUMO

Seasonally frozen soil where uneven freeze-thaw damage is a major cause of highway deterioration has attracted increased attention in China with the rapid development of infrastructure projects. Based on Darcy's law of unsaturated soil seepage and heat conduction, the thermal-hydraulic-mechanical (THM) coupling model is established considering a variety of effects (i.e., ice-water phase transition, convective heat transfer, and ice blocking effect), and then the numerical solution of thermal-hydraulic fields of subgrade can be obtained. Then, a new concept, namely degree of freeze-thaw damage, is proposed by using the standard deviation of the ice content of subgrade during the annual freeze-thaw cycle. To analyze the freeze-thaw characteristics of highway subgrade, the model is applied in the monitored section of the Golmud to Nagqu portion of China National Highway G109. The results show that: (1) The hydrothermal field of subgrade has an obvious sunny-shady slopes effect, and its transverse distribution is not symmetrical; (2) the freeze-thaw damage area of subgrade obviously decreased under the insulation board measure; (3) under the combined anti-frost measures, the maximum frost heave amount of subgrade is significantly reduced. This study will provide references for the design of highway subgrades in seasonally frozen soil areas.


Assuntos
Solo , Água , China , Congelamento
14.
Electrophoresis ; 2020 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-33043482

RESUMO

Lab-on-a-chip (LOC) technologies can take advantage of sheath flows for particle/cell focusing before sensing or sorting. The integration of focusing with other microscale manipulation techniques (e.g., sorting) creates a trade-off between the throughput of the device and its performance. Therefore, exploring the effective parameters for cells/particles focusing enables us to improve the desired output of LOC devices. A common configuration for sheath-assisted focusing is Y junctions, which are parametrically studied in this paper. First, a computational model was developed and validated by comparing it with our experimental results. Using COMSOL Multiphysics modeling, the effects of multiple parameters were studied. These parameters include the sheath flow ratio (sheath flow over total flow), width ratio (width of the sheath inlet over the total width), junction angles, and particle size on the focusing width and the distribution of the particles within the focusing region. Then, the numerical data were used to develop two generalized linear models to predict the focusing width of the particles and the standard deviation of the position of the particles. The results showed that the focusing width is greatly impacted by the sheath flow rate ratio. Further, the standard deviation of the position of the particles, which represents the concentration of the particles, is mostly dependent on the flow rate ratio, width ratio, and particle size. Our results provide a better understanding of how the device geometrical and operational factors affect the position of the particles in the development of high-performance on-chip sensing and sorting of both cells and particles.

15.
Sensors (Basel) ; 20(5)2020 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-32120959

RESUMO

In the Czech part of the Upper Silesian Coal Basin (Moravian-Silesian region, Czech Republic), there are many deposits of endogenous combustion (e.g., localized burning soil bodies, landfills containing industrial waste, or slag rocks caused by mining processes). The Hedwig mining dump represents such an example of these sites where, besides the temperature and the concentrations of toxic gases, electric and non-electric quantities are also monitored within the frame of experimentally proposed and patented technology for heat collection (the so-called "Pershing" system). Based on these quantities, this paper deals with the determination and evaluation of negative heat sources and the optimization of the positive heat source dependent on measured temperatures within evaluation points or on a thermal profile. The optimization problem is defined based on a balance of the heat sources in the steady state while searching for a local minimum of the objective function for the heat source. From an implementation point of view, it is the interconnection of the numerical model of the heat collector in COMSOL with a user optimization algorithm in MATLAB using the LiveLink for MATLAB. The results are elaborated in five case studies based on the susceptibility testing of the numerical model by input data from the evaluation points. The tests were focused on the model behavior in terms of preprocessing for measurement data from each chamber of the heat collector and for the estimated value of temperature differences at 90% and 110% of the nominal value. It turned out that the numerical model is more sensitive to the estimates in comparison with the measured data of the chambers, and this finding does not depend on the type optimization algorithm. The validation of the model by the use of the mean-square error led to the finding of optimal value, also valid with respect to the other evaluation.

16.
Plant Cell Environ ; 42(2): 466-479, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30074610

RESUMO

The sugar conducting phloem in angiosperms is a high resistance pathway made up of sieve elements bounded by sieve plates. The high resistance generated by sieve plates may be a trade-off for promoting quick sealing in the event of injury. However, previous modeling efforts have demonstrated a wide variation in the contribution of sieve plates towards total sieve tube resistance. In the current study, we generated high resolution scanning electron microscope images of sieve plates from balsam poplar and integrated them into a mathematical model using Comsol Multiphysics software. We found that sieve plates contribute upwards of 85% towards total sieve tube resistance. Utilizing the Navier-Stokes equations, we found that oblong pores may create over 50% more resistance in comparison with round pores of the same area. Although radial water flows in phloem sieve tubes have been previously considered, their impact on alleviating pressure gradients has not been fully studied. Our novel simulations find that radial water flow can reduce pressure requirements by half in comparison with modeled sieve tubes with no radial permeability. We discuss the implication that sieve tubes may alleviate pressure requirements to overcome high resistances by regulating their membrane permeability along the entire transport pathway.


Assuntos
Modelos Teóricos , Floema/fisiologia , Microscopia Eletrônica de Varredura , Pressão Osmótica , Floema/ultraestrutura , Populus/fisiologia , Populus/ultraestrutura , Água/metabolismo
17.
Theor Biol Med Model ; 16(1): 12, 2019 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-31422770

RESUMO

BACKGROUND: Photothermal therapy is a local treatment method for cancer and the heat energy generated from it could destroy the tumor cells. This study is aimed to investigate the temperature distribution in tumor tissue and surrounding health tissue of tumor bearing mice applying mathematical simulation model. Tumor bearing mice treated by laser combined with or without indocyanine green. Monte Carlo method and the Pennes bio-heat equation were used to calculate the light distribution and heat energy. COMSOL Multiphysic was adopted to construct three dimensional temperature distribution model. RESULTS: This study revealed that the data calculated by simulation model is in good agreement with the surface temperature monitored by infrared thermometer. Effected by the optical parameters and boundary conditions of tissue, the highest temperature of tissue treated by laser combined with indocyanine green was about 65 °C which located in tumor tissue and the highest temperature of tissue treated by laser was about 43 °C which located under the tumor tissue. The temperature difference was about 20 °C. Temperature distribution in tissue was not uniform. The temperature difference in different parts of tumor tissue raised up to 15 °C. The temperature of tumor tissue treated by laser combined with indocyanine green was about 20 °C higher than that of the surrounding healthy tissue. CONCLUSIONS: Reasonably good matching between the calculated temperature and the measured temperature was achieved, thus demonstrated great utility of our modeling method and approaches for deepening understand in the temperature distribution in tumor tissue and surrounding healthy tissue during the laser combined with photosensitizer. The simulation model could provide guidance and reference function for the effect of photothermal therapy.


Assuntos
Simulação por Computador , Verde de Indocianina/farmacologia , Terapia a Laser , Neoplasias/terapia , Temperatura , Animais , Linhagem Celular Tumoral , Feminino , Camundongos Endogâmicos BALB C , Método de Monte Carlo , Neoplasias/patologia , Fatores de Tempo
18.
Sensors (Basel) ; 18(8)2018 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-30096759

RESUMO

In this study, we study a heat transfer model, with the surface of the microbolometer device receiving radiation from blackbody constructed using a COMSOL Multiphysics simulator. We have proposed three kinds of L-type 2-leg and 4-leg with the pixel pitch of 35 µm based on vanadium oxide absorbent membrane sandwiched with top passivated and bottom Si3N4 supporting films, respectively. Under the blackbody radiation, the surface temperature changes and distributions of these samples are simulated and analyzed in detail. The trend of change of the temperature dependent resistance of the four kinds of bolometer devices using the proposed heat transfer model is consistent with the actual results of the change of resistance of 4 samples irradiated with 325 K blackbody located in the front distance of 5 cm. In this paper, ΔT indicates the averaged differences of the top temperature on the suspended membrane and the lowest temperature on the post of legs of the microbolometers. It is shown that ΔT ≈ 17 mK is larger in nominal 2-leg microbolometer device than that of 4-leg one and of 2-leg with 2 µm × 2 µm central square hole and two 7.5 µm × 2 µm slits in suspended films. Additionally, only ΔT ≈ 5 mK with 4-leg microbolometer device under the same radiated energy of 325 K blackbody results from the larger total thermal conductance.

19.
Electromagn Biol Med ; 35(2): 152-60, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26115000

RESUMO

Malignant liver tumors are the sixth most common and deadly cancer in the world and the third most common cause of cancer mortality. Hepatocellular carcinoma (primary liver cancer) is one of the most common malignancies worldwide with one of the highest mortality rates. Microwave ablation (MWA) is a new, promising, and multidisciplinary technology designed to destroy unhealthy tissue of various natures by radiating electromagnetic waves with microwave antennas. The finite element method (FEM) has been used in the present work to generate the simulated models of tapered cap floating sleeve antenna for validation of its design concepts, because FEM allows modeling of complex geometries that cannot be solved by analytical methods or finite difference models. The performances have been evaluated in terms of objective metrics, ablation zone, antenna matching, power absorption and SAR pattern.


Assuntos
Técnicas de Ablação/instrumentação , Carcinoma Hepatocelular/terapia , Análise de Elementos Finitos , Neoplasias Hepáticas/terapia , Micro-Ondas/uso terapêutico
20.
Electrophoresis ; 35(5): 646-53, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24258617

RESUMO

An ITP separation of eight lanthanides on a serpentine PMMA microchip with a tee junction and a 230-mm-long serpentine channel is described. The cover of the PMMA chip is 175 µm thick so that a C(4) D in microchip mode can be used to detect the lanthanides as they migrate through the microchannel. Acetate and α-hydroxyisobutyric acid are used as complexing agents to increase the electrophoretic mobility difference between the lanthanides. Eight lanthanides are concentrated within ∼ 6 min by ITP in the microchip using 10 mM ammonium acetate at pH 4.5 as the leading electrolyte and 10 mM acetic acid at ∼ pH 3.0 as the terminating electrolyte. In addition, a 2D numerical simulation of the lanthanides undergoing ITP in the microchip is compared with experimental results using COMSOL Multiphysics v4.3a.


Assuntos
Eletroforese em Microchip/instrumentação , Eletroforese em Microchip/métodos , Elementos da Série dos Lantanídeos/isolamento & purificação , Acetatos/química , Simulação por Computador , Desenho de Equipamento , Concentração de Íons de Hidrogênio , Hidroxibutiratos/química , Polimetil Metacrilato , Processamento de Sinais Assistido por Computador