Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 143
Filtrar
1.
Luminescence ; 39(2): e4682, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38332466

RESUMO

A new, proven, economical spectrofluorimetric approach has been used to determine the proton pump inhibitor omeprazole (OMP). This innovative technique is based on the ability of OMP to quench the native fluorescence of the mercurochrome dye in an acidic (pH 3.6) solution. Because it was discovered that quenching is proportional to the drug concentration, this dye was used as a sensor for OMP detection. The fluorescence intensity was measured at 518/540 nm, and its linear response ranged from 0.2-10.0 µg/mL with a linear coefficient of 0.9999. The computation yielded a limit of quantification (LOQ) of 0.20 µg/mL and a limit of detection (LOD) of 0.07 µg/mL. Every circumstance and element impacting the reaction product was examined in detail. Pharmacopeial standards carried out the validation. The approved method investigated several commercial preparations and formulations, and the results were favorably compared with those provided by a reference method. According to United States Pharmacopeia (USP) rules, content consistency for two distinct formulations was evaluated.


Assuntos
Omeprazol , Comprimidos/química , Limite de Detecção , Espectrometria de Fluorescência/métodos
2.
Luminescence ; 39(4): e4741, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38605268

RESUMO

In the present study, a first validated and green spectrofluorimetric approach for its assessment and evaluation in different matrices was investigated. After using an excitation wavelength of 345 nm, Roxadustat (ROX) demonstrates a highly native fluorescence at an emission of 410 nm. The influences of experimental factors such as pH, diluting solvents, and different organized media were tested, and the most appropriate solvent choice was ethanol. It was confirmed that there was a linear relationship between the concentration of ROX and the relative fluorescence intensity in the range 60.0-1000.0 ng ml-1, with the limit of detection and limit of quantitation, respectively, being 17.0 and 53.0 ng ml-1. The mean recoveries % [±standard deviation (SD), n = 5] for pharmaceutical preparations were 100.11% ± 2.24%, whereas for plasma samples, they were 100.08 ± 1.08% (±SD, n = 5). The results obtained after the application of four greenness criteria, Analytical Eco-Scale metric, NEMI, GAPI, and AGREE metric, confirmed its eco-friendliness. In addition, the whiteness meter (RGB12) confirmed its level of sustainability. The International Council for Harmonisation (ICH) criteria were used to verify the developed method through the study in both spiked plasma samples and content uniformity evaluation. An appropriate standard for various applications in industry and quality control laboratories was developed.


Assuntos
Hematínicos , Humanos , Limite de Detecção , Espectrometria de Fluorescência/métodos , Eritropoese , Concentração de Íons de Hidrogênio , Solventes/química , Comprimidos/química , Isoquinolinas
3.
Luminescence ; 38(12): 2065-2072, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37740522

RESUMO

The prokinetic drug, prucalopride (PCP) succinate, was determined using a new spectrofluorimetric approach with a highly sensitive, rapid, and simple procedure. The method exploited the enhancement of the inherent native fluorescence of PCP by micellar aggregation with sodium lauryl sulfate (SLS) as an anionic surfactant. Different factors that could affect the fluorescence intensity were carefully studied in order to achieve the maximal fluorescence signal. Measurement of the enhanced fluorescence was done at 354 nm after the excitation at 276 nm. The fluorescence intensity-concentration plot was rectilinear in the concentration range of 50-600 ng/ml with detection and quantitation limits of 13.9 and 42.1 ng/ml, respectively. The method underwent validation according to the International Council for Harmonisation criteria in order to assess its analytical performance, and promising results were achieved that proved the validity and reliability of the method. Furthermore, the method was employed effectively for the analysis of the cited drug in commercial pharmaceutical tablets.


Assuntos
Succinatos , Limite de Detecção , Espectrometria de Fluorescência/métodos , Reprodutibilidade dos Testes , Comprimidos/análise
4.
Arch Pharm (Weinheim) ; 356(6): e2300005, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37010439

RESUMO

The endemicity of the pandemic coronavirus disease 2019 (COVID-19) infection proved to be transitional only. Spikes are forming again in 2023, and high expectations are returning for reinfections and viral mutations. Molnupiravir (MOL) has been approved as an oral antiviral drug for the treatment of the COVID-19 causative virion. Therefore, the development of an ultrasensitive, instantaneous, and cost-effective method for the quantification of MOL in real plasma samples and formulated dosage form are mandatory. The proposed approach is based on the synthesis of a MOL metal-chelation product. MOL as a ligand was chelated with 1.0 mM zinc(II) in an acetate buffer (pH 5.3). After illumination at 340 nm, the intensity of the MOL fluorescence measured at 386 nm was increased by about 10-fold. The linearity range was found to be from 60.0 to 800.0 ng mL-1 with limit of quantitation (LOQ) of 28.6 ng mL-1 . Two methods were utilized for measuring the greenness of the proposed method (Green Analytical Procedure Index [GAPI] and analytical greenness metric [AGREE] methods), with results equal to 0.8. The binding stoichiometry of MOL with the zinc(II) ion was found to be 2:1. All the experimental parameters were optimized and validated using International Conference on Harmonization (ICH) and United States Food and Drug Administration (US-FDA) recommendations. Furthermore, the fluorescent probes were successfully utilized in real human plasma with high percentages of recovery (95.6%-97.1%) without any matrix interferences. The mechanism of fluorescent complex formation was confirmed using 1 H NMR in the presence and absence of Zn(II). The method was further utilized for testing content uniformity of MOL in its marketed capsule dosage forms.


Assuntos
COVID-19 , Zinco , Humanos , Espectrometria de Fluorescência/métodos , Relação Estrutura-Atividade , Preparações Farmacêuticas
5.
Pharm Dev Technol ; 28(3-4): 265-276, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36847606

RESUMO

Near Infrared and Raman spectroscopy-based Process Analytical Technology tools were used for monitoring blend uniformity (BU) and content uniformity (CU) for solid oral formulations. A quantitative Partial Least Square model was developed to monitor BU as real-time release testing at a commercial scale. The model having the R2, and root mean square error of 0.9724 and 2.2047, respectively can predict the target concentration of 100% with a 95% confidence interval of 101.85-102.68% even after one year. The tablets from the same blends were investigated for CU using NIR and Raman techniques both in reflection and transmission mode. Raman reflection technique was found to be the best and the PLS model was developed using tablets compressed at different concentrations, hardness, and speed. The model with R2 and RMSE of 0.9766 and 1.9259, respectively was used for the quantification of CU. Both the BU and CU models were validated for accuracy, precision, specificity, linearity, and robustness. The accuracy was proved against the HPLC method with a relative standard deviation of less than 3%. The equivalency for BU by NIR and CU by Raman was evaluated using Schuirmann's Two One-sided tests and found equivalent to HPLC within a 2% acceptable limit.


Assuntos
Espectroscopia de Luz Próxima ao Infravermelho , Análise Espectral Raman , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Análise Espectral Raman/métodos , Comprimidos/química , Composição de Medicamentos/métodos , Análise dos Mínimos Quadrados , Calibragem
6.
Ann Pharm Fr ; 81(2): 267-283, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36126752

RESUMO

OBJECTIVES: Newly, baricitinib (Olumiant) is FDA-confirmed for treating adult patients with slightly to highly active rheumatoid arthritis who have a terrible reaction to several treatments against the tumor necrosis factor. The efficacy and safety of baricitinib have been determined by the FDA, so, a precise, and sensitive stability-indicating RP-HPLC method is issued to determine baricitinib and its degradation products in their film-coated tablet dosage form; application to content uniformity and in-vitro dissolution studies. METHODS: The analysis of assay and dissolution tests are released using an isocratic elution system while impurities are performed using gradient profile for mobile phase comprising of Buffer Solution: Methanol in Proportion (65:35, v/v) at flow rate 1.0mL/minute, column BDS Hypersil C18 5µm 150×4.6mm, column temperature 30̊C, injection volume 10µL, detection wavelength 290nm using DAD detector. RESULTS: Calibration charts are acquired in the linearity range (1-30µg/mL) of baricitinib with a correlation coefficient=0.9999 with good recovery results between (99-100%). CONCLUSION: The proposed procedure was fully validated regarding Linearity, Accuracy, LOD, LOQ, Precision, Robustness, and Specificity, and there is no overlapping owing to deterioration peaks. Furthermore, the method has been accomplished to study content uniformity testing and in-vitro dissolution.


Assuntos
Azetidinas , Humanos , Limite de Detecção , Solubilidade , Comprimidos/análise , Cromatografia Líquida de Alta Pressão/métodos
7.
J Fluoresc ; 32(5): 1725-1732, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35670919

RESUMO

Vonoprazan (VON) has been approved recently via US-FDA in 2015 as the first in class of potassium competitive acid blocker group. VON is used for management of GIT ulcer, reflux esophagitis and for eradication of Helicobacter pylori. So, the first spectrofluorimetric method was developed for estimation of VON in real human plasma and content uniformity test. The fluorimetric methodology based on reaction of secondary amine group in VON with benzofurazan (0.05% w/v NBD-Cl) reagent as nucleophilic substitution reaction in alkaline medium (0.1 M borate buffer pH 8.2) to produce highly fluorescent product measure at 530 nm after excitation at 465 nm. The linear calibration range was found 15 to 200 ng mL-1 with lower limit of quantitation (LOQ) equal to 8.57 ng mL-1. The method was successfully applied for estimation of VON in pharmacokinetic (PK) and content uniformity studies. The maximum plasma concentration was found to be (Cmax) 71.03 ng mL-1 after maximum time (tmax) equal to 1.5 ± 0.15 h. The presented strategy also applied to ensure concentration of drug in each tablet using content uniformity test with high percent of recovery 100.05 ± 0.66. The proposed method was established for clinical laboratories and therapeutic drug monitoring studies.


Assuntos
Pirróis , Sulfonamidas , Fluorometria , Humanos , Espectrometria de Fluorescência/métodos
8.
Luminescence ; 37(7): 1057-1063, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35416388

RESUMO

A novel, simple and sensitive spectrofluorimetric approach for determination of terbutaline sulphate (TER) and its prodrug bambuterol (BAM) in their pure and pharmaceutical dosage forms was developed. The suggested approach depends on enhancing the native fluorescence of either TER or BAM at 315 and 297.2 nm after excitation at 277 and 259 nm, respectively, using sodium dodecyl sulphate (SDS) as a micellar medium. In the presence of 0.7% w/v SDS, ~1.38-fold and 1.18-fold enhancement is achieved in the relative fluorescence intensity (RFI) of TER and BAM, respectively. The fluorescence-concentration curves were rectilinear over the concentration range 0.8-16 µg ml-1 , with detection limits (LOD) of 0.252 and 0.26 (µg ml-1 ), quantitation limits (LOQ) of 0.76 and 0.79 (µg ml-1 ), determination coefficients (r2) of 0.9981, and slopes of 45.92 and 10.44 for TER and BAM, respectively. The suggested approach was validated in accordance with International Council for Harmonisation criteria and was effectively applied in the analysis of the studied drugs in their commercial tablets. The high sensitivity of the proposed approach allows its application in evaluating the content uniformity testing of the studied drugs in their tablets through using the official United States Pharmacopeia criteria. Statistical analogies of the findings with that of the reported methods showed really good harmony and indicated no major differences in precision and accuracy.


Assuntos
Micelas , Pró-Fármacos , Broncodilatadores , Limite de Detecção , Espectrometria de Fluorescência/métodos , Comprimidos/análise , Terbutalina/análogos & derivados
9.
Molecules ; 27(12)2022 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-35744885

RESUMO

Non-destructive analysis of chlorpheniramine maleate (CPM), pharmaceutical tablets, and granules was conducted by chemometrics-assisted attenuated total reflectance infrared spectroscopy (ATR-IR). For tablets, an optimum PLSR model with eight latent factors was obtained from area-normalized and standard normal variate (SNV) pretreated ATR-IR spectral data with correlation coefficients (R2) of calibration and cross-validation of 0.9716 and 0.9602, respectively. The model capability for the 42 test set samples was proven with R2 between the reference and model prediction values of 0.9632, and a root-mean-square error of prediction (RMSEP) of 1.7786. The successive PLSR model for granules was constructed from SNV and first derivative pretreated ATR-IR spectral data with two latent factors and correlation coefficients (R2) of calibration and cross-validation of 0.9577 and 0.9450, respectively.


Assuntos
Quimiometria , Clorfeniramina , Calibragem , Análise dos Mínimos Quadrados , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Comprimidos
10.
J Fluoresc ; 31(6): 1871-1881, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34524574

RESUMO

A simple, novel, cost-effective and highly sensitive spectrofluorimetric method was developed for estimation of the nasal decongestant oxymetazoline (OMZ) whether per se or in its pharmaceutical preparations using colloidal silver nanoparticles (AgNPs). The method is based on the high catalytic potential activity of AgNPs on the fluorescence intensity of OMZ leading to 12-fold increase in its fluorescence intensity. The response was linear over the range of 20.0 to 700.0 ng/mL with lower detection limit of 5.0 ng/mL and limit of quantification of 14.0 ng/mL. The proposed method was applied to the assay of commercial nasal drops, nasal spray and synthetic aqueous humor. Interference likely to be encountered from co-administered drugs was studied. The developed method was optimized and validated as per International Council of Harmonization (ICH). An explanation for the drug-AgNPs interaction was proposed.


Assuntos
Humor Aquoso/química , Nanopartículas Metálicas/química , Oximetazolina/análise , Prata/química , Ressonância de Plasmônio de Superfície , Fluorescência , Espectrometria de Fluorescência
11.
Luminescence ; 36(3): 588-594, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33140532

RESUMO

In the current proposed analysis, a new, feasible, and selective fluorimetric approach was designed for baclofen assay. Baclofen is a medication prescribed as a therapy for muscle spasticity that originated from multiple sclerosis or a spinal cord injury, and other cases such as hiccups. The analytical approach relies on the use of ninhydrin to form a fluorescent derivative that was monitored at λex 386 nm or λem 480 nm. Under suitable reaction conditions, the primary amino moiety in baclofen was condensed with ninhydrin and phenylacetaldehyde in the presence of Teorel buffer as a buffered medium. The method exhibited linearity when baclofen concentration was plotted against response in the range 1-10 µg ml-1 . Adjustment of the reaction variables and study of validation parameters according to ICH directives were performed correctly. An interference study was implemented to ensure that no discrepancy from the excipient had occurred. Finally, the proposed method was applied successfully for baclofen assay in dosage form and extended to test Mylobac content uniformity.


Assuntos
Baclofeno , Ninidrina , Fluorometria , Indicadores e Reagentes , Espectrometria de Fluorescência
12.
Saudi Pharm J ; 29(6): 516-526, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34194258

RESUMO

Quality by Design (QbD) and chemometric models are different sides of the same coin. While QbD models utilize experimentally designed settings for optimization of some quality attributes, these settings can also be utilized for chemometric prediction of the same attributes. We aimed to synchronize optimization of comparative dissolution results of carvedilol immediate release tablets with chemometric prediction of dissolution profile and content uniformity of the product. As an industrial application, selection of variables for optimization was done by performing risk assessment utilizing the archived product records at the pharmaceutical site. Experimental tablets were produced with 20 different settings with the variables being contents of sucrose, sodium starch glycolate, lactose monohydrate, and avicel Ph 101. Contents of the excipients were modelled with F1 dissimilarity factor and F2 similarity factor in HCL, acetate, and USP dissolution media to determine the design space. We initiatively utilized Partial Least Square based Structural Equation Modelling (PLS-SEM) to explore how the excipients and their NIR records explained dissolution of the product. Finally, the optimized formula was utilized with varied content of carvedilol for chemometric prediction of the content uniformity.

13.
Chem Pharm Bull (Tokyo) ; 68(2): 155-160, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32009083

RESUMO

Combination tablets containing multiple active pharmaceutical ingredients (APIs) are expected to improve patient convenience by decreasing the number of tablets to be taken; thus, numerous formulations containing multiple APIs have recently been developed. To allow for dose adjustments based on patient conditions, many tablets have a bisection line to allow equal division of tablets. However, there have been no investigations regarding content uniformity among divided combination tablets. Therefore, in this study, the content uniformity of combination tablets after division was investigated using near IR and low-frequency (LF) Raman spectroscopy imaging as well as the Japanese Pharmacopoeia (JP) content uniformity tests. As model drugs, five tablets of three combination drugs containing 3-(3,4-dihydroxyphenyl)-L-alanine (L-DOPA) and benserazide hydrochloride (BNS) as APIs for treating Parkinson's disease were bisected; the resultant 10 samples were subjected to the JP content uniformity tests. We found that acceptance values of L-DOPA and BNS were 11.0-21.9% and 13.3-17.5%, respectively, with some non-conformity to the maximum allowed acceptance value (15.0%) as per the current JP. Image analyses by near IR showed that L-DOPA, BNS, lactose, and corn starch were uniformly distributed in each tablet; moreover, LF Raman spectroscopy imaging also supported the result that L-DOPA, BNS, and lactose were evenly distributed. Therefore, drug content in the tablets was uniform; thus, careful manipulation was recommended in the tablet bisection. However, the results of bisection line specifications and hardness tests revealed that the ease of division differed depending on the tablets, which warrants attention.


Assuntos
Antiparkinsonianos/análise , Benserazida/análise , Levodopa/análise , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Análise Espectral Raman/métodos , Combinação de Medicamentos , Comprimidos
14.
Pharm Dev Technol ; 25(7): 899-907, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32324081

RESUMO

Calcitriol, as the biologically active form of vitamin D3, is essential for patients with renal osteopathy. The solubilization, stabilization, and content uniformity are key issues in its formulation development. In our previous study, the incomplete release of calcitriol was solved by using the hybrid lipid-based solid dispersion (SD) for calcitriol. However, good stability and content uniformity are still urgently needed. In this study, solid lipid with antioxidant properties and liquid lipid compatible with calcitriol were employed as hybrid lipid carrier (HLC) to establish a solid dispersion. Moreover, the content uniformity of tablets with hybrid lipid carrier based SDs (HLCTs) was further guaranteed due to the multi-dispersion of calcitriol in HLC, solidification, and blank granules. Additionally, the compression of the blank granules was adjusted by the water content. The mixing method of calcitriol-containing and blank granules was also optimized. The obtained HLCTs were evaluated for hardness, disintegration time, in vitro drug dissolution, content uniformity, and stability. Satisfactory HLCTs were developed successfully in this study with superior content uniformity and better stability than the commercial soft capsule (Rocaltrol®). It was proved to be a promising formulation for drugs with poor water-solubility, instability to oxygen and heat, and dose-related toxicity.


Assuntos
Conservadores da Densidade Óssea/síntese química , Calcitriol/síntese química , Portadores de Fármacos/síntese química , Composição de Medicamentos/métodos , Conservadores da Densidade Óssea/administração & dosagem , Conservadores da Densidade Óssea/farmacocinética , Calcitriol/administração & dosagem , Calcitriol/farmacocinética , Portadores de Fármacos/administração & dosagem , Portadores de Fármacos/farmacocinética , Liberação Controlada de Fármacos/fisiologia , Estabilidade de Medicamentos , Comprimidos
15.
Saudi Pharm J ; 28(11): 1301-1308, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33250639

RESUMO

Risedronate is a nitrogen-containing bisphosphonate for the treatment and prevention of postmenopausal osteoporosis. The current work aims to develop a novel green HPLC-UV method for the rapid analysis of risedronate sodium in bulk and tablet formulation. The analyzed samples were separated on Waters Atlantis dC18 (150 mm × 3.9 mm; 5 µm) column using a green mobile phase consisting of potassium phosphate buffer pH 2.9 and potassium edetate buffer pH 9.5 in a ratio of 1:2, the final pH was adjusted to 6.8 with phosphoric acid, the mobile phase was pumped at a rate of 1.0 mL/min, with column temperature set at 30 °C, eluted samples were detected at 263 nm and the chromatographic run time was 3.0 min. The method was found to be linear over the concentration range of 14-140 µg/mL with a correlation coefficient (r2) of 0.9994. Accuracy and precision were evaluated from three QC samples (LQC, MQC and HQC) together with the five calibrators where the percentage accuracy was found to be 101.84%. Processed quality control samples of risedronate sodium were tested for stability at different conditions, short term, long term and freeze- thaw stability. The current method was further extended to study the content uniformity of Actonel® tablets following United States Pharmacopoeia (USP) guidelines. The proposed method was fully validated as per ICH guidelines.

16.
Ceska Slov Farm ; 69(1): 33-42, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32460508

RESUMO

The aim of this work was to develop medicated chewing gums (MCGs) containing 10 mg of lysozyme hydrochloride (LH) and 20 mg of ascorbic acid (AsA) obtained by the compression method with Health in Gum® (HiG®) PWD 01 as a compressible gum base. Because of a low content of active ingredients, it was essential to choose the way of adding them to the tableting mass and evaluate their distribution homogeneity in the dosage units. The blends for compression were prepared by two methods: the first one was simple mixing of all components; the second one included the step of wet granulation of a three-component mixture - LH, sucralose and a taste additive. Flow properties of LH, AsA, HiG®, LH granules and blends for compression were studied. MCGs were evaluated according to Ph.Eur. 9.0 Chapters 2.9.5, 2.9.6 and 2.9.40. AsA and HiG® were characterized as free flowing, while LH had insufficient flow properties. Compared with a simple mixed blend, the granulation step allowed significantly improving flow properties of the final blend for compression. Unlike MCGs compressed from the simple mixed blend, MCGs prepared through the granulation step met Ph.Eur. 9.0 Chapter 2.9.40 requirements. The propriety of MCG preparation method involving the step of wet granulation also has been confirmed by mass and drug content uniformity tests.


Assuntos
Ácido Ascórbico/administração & dosagem , Goma de Mascar , Portadores de Fármacos , Muramidase/administração & dosagem
17.
Luminescence ; 34(8): 854-858, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31338979

RESUMO

A novel, simple, sensitive method was developed for determining midodrine spectrofluorimetrically in both its raw pure form and its tablet form. This study is based on the native fluorescence of midodrine and discusses the optimum solvent used and the wavelength range. The presented method was then validated with respect to linearity, accuracy, precision, and limits of detection and quantitation. The constructed calibration curve showed a linear range of 0.1-2.0 µg/ml. The limit of detection and limit of quantitation values were 0.03 and 0.10 µg/ml respectively. Finally, content uniformity testing was applied according to the United States Pharmacopoeia by adapting the presented method.


Assuntos
Midodrina/análise , Calibragem , Composição de Medicamentos , Fluorescência , Espectrometria de Fluorescência , Comprimidos/análise
18.
Luminescence ; 34(1): 70-76, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30430753

RESUMO

Bambuterol (BAM) and terbultaline (TER) are well known and effective bronchodilators. In this article highly sensitive, green and cost-effective spectrofluorimetric methods are designed to determine low concentrations of such drugs. The proposed methods are based on an investigation of the native fluorescence properties of aqueous solutions of BAM at 298 nm after excitation at 263 nm and of TER at 313 nm after excitation at 275 nm. Under optimum conditions, the plots of the relative fluorescence intensity versus concentration were rectilinear over the range 0.1-1.2 µg/mL for BAM and 0.05-0.5 µg/mL for TER with a limit of quantitation of 0.067 µg/mL for BAM and 0.018 µg/mL for TER. The methods are simple and hence suitable for application to the quantification of BAM and TER in syrups and tablets without interference from common excipients. Furthermore, based on United States Pharmacopeia (USP) guidelines, the application was extended to determine the content uniformity of the cited drugs in low dose tablets. The developed methods were fully validated according to the guidelines of the International Conference on Harmonization (ICH).


Assuntos
Espectrometria de Fluorescência/métodos , Terbutalina/análogos & derivados , Terbutalina/análise , Calibragem , Química Verde , Concentração de Íons de Hidrogênio , Limite de Detecção , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Solventes/química , Comprimidos/análise
19.
Luminescence ; 34(1): 84-89, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30536965

RESUMO

A novel sensitive and simple spectrofluorimetric method was developed then validated for determination of midodrine in both its authentic pure form and its tablets. This method is based on the reaction between midodrine's aliphatic primary amine moiety with fluorescamine reagent, using borate buffer at pH 7.8 and yielding a highly fluorescent product whose fluorescence intensity was measured at 462 nm after excitation at 388 nm. This method represents the first attempt for determination of midodrine spectrofluorimetrically. A calibration curve was constructed showing that the linear range was 0.2-3.0 µg/ml. The limit of detection and limit of quantitation values were 0.06 and 0.19 µg/ml respectively. The correlation coefficient (r) and the determination coefficient (r2 ) values were 0.9992 and 0.9984 respectively. The proposed method was validated according to ICH guidelines and successfully applied for determination of midodrine in its tablets with an overall % recovery of 99.56 ± 0.95. Finally, the presented method was adapted to study the content uniformity test according to United States Pharmacopeia guidelines.


Assuntos
Fluorescamina/química , Midodrina/análise , Espectrometria de Fluorescência/métodos , Soluções Tampão , Calibragem , Concentração de Íons de Hidrogênio , Indicadores e Reagentes/química , Limite de Detecção , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Solventes/química , Comprimidos/análise , Fatores de Tempo
20.
Pharm Dev Technol ; 24(2): 145-156, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29394129

RESUMO

The SeDeM Expert Diagram System (SeDeM EDS) was originally developed to provide information about the suitability of powders to produce direct compressible tablets. Multiple-unit pellet systems (MUPS) are dosage forms consisting of pellets compressed into tablets or loaded into hard gelatin capsules. The aim of this study was to apply the SeDeM EDS to different size pellets (i.e. 0.5, 1.0, 1.5, 2.0, and 2.5 mm) containing different APIs (i.e. doxylamine, ibuprofen or paracetamol) to determine which properties should be corrected to yield MUPS tablet formulations. The SeDeM parameter tests were conducted on the pellets, selected excipients, intermediate blends, and final blends. The study showed that the properties of the pellets depended on the active ingredient and pellet size. The SeDeM compressibility indices indicated that the final pellet blends should be suitable for compression into MUPS tablets. MUPS tablets were prepared from the final blends and evaluated in terms of physico-chemical properties and dissolution profiles. Only three of the MUPS tablet formulations containing ibuprofen and one MUPS tablet formulation containing paracetamol failed content uniformity. The water solubility of the APIs as well as the pellet size (surface area exposed to the dissolution medium) attributed to the difference in drug dissolution rate.


Assuntos
Implantes de Medicamento/química , Comprimidos/química , Química Farmacêutica/métodos , Composição de Medicamentos/métodos , Liberação Controlada de Fármacos , Excipientes/química , Sistemas Inteligentes , Dureza , Ibuprofeno/química , Tamanho da Partícula , Pós/química , Solubilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA