Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Magn Reson Med ; 91(1): 413-423, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37676121

RESUMO

PURPOSE: In this study, we compared two triarylmethyl (TAM) spin probes, Ox071 and Ox063 for their efficacy in measuring tissue oxygen levels under hypoxic and normoxic conditions by R2 *-based EPR oximetry. METHODS: The R2 * dependencies on the spin probe concentration and oxygen level were calibrated using deoxygenated 1, 2, 5, and 10 mM standard solutions and 2 mM solutions saturated at 0%, 2%, 5%, 10%, and 21% of oxygen. For the hypoxic model, in vivo imaging of a MIA PaCa-2 tumor implanted in the hind leg of a mouse was performed on successive days by R2 *-based EPR oximetry using either Ox071 or Ox063. For the normoxic model, renal imaging of healthy athymic mice was performed using both spin probes. The 3D images were reconstructed by single point imaging and multi-gradient technique was used to determine R2 * maps. RESULTS: The signal intensities of Ox071 were approximately three times greater than that of Ox063 in the entire partial pressure of oxygen (pO2 ) range investigated. The histograms of the tumor pO2 images were skewed for both spin probes, and Ox071 showed more frequency counts at pO2 > 32 mm Hg. In the normoxic kidney model, there was a clear delineation between the high pO2 cortex and the low pO2 medulla regions. The histogram of high-resolution kidney oximetry image using Ox071 was nearly symmetrical and frequency counts were seen up to 55 mm Hg, which were missed in Ox063 imaging. CONCLUSION: As an oximetric probe, Ox071 has clear advantages over Ox063 in terms of sensitivity and the pO2 dynamic range.


Assuntos
Neoplasias , Oximetria , Camundongos , Animais , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Oximetria/métodos , Oxigênio , Imageamento Tridimensional
2.
BJU Int ; 133(6): 690-698, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38343198

RESUMO

OBJECTIVE: To automate the generation of three validated nephrometry scoring systems on preoperative computerised tomography (CT) scans by developing artificial intelligence (AI)-based image processing methods. Subsequently, we aimed to evaluate the ability of these scores to predict meaningful pathological and perioperative outcomes. PATIENTS AND METHODS: A total of 300 patients with preoperative CT with early arterial contrast phase were identified from a cohort of 544 consecutive patients undergoing surgical extirpation for suspected renal cancer. A deep neural network approach was used to automatically segment kidneys and tumours, and then geometric algorithms were used to measure the components of the concordance index (C-Index), Preoperative Aspects and Dimensions Used for an Anatomical classification of renal tumours (PADUA), and tumour contact surface area (CSA) nephrometry scores. Human scores were independently calculated by medical personnel blinded to the AI scores. AI and human score agreement was assessed using linear regression and predictive abilities for meaningful outcomes were assessed using logistic regression and receiver operating characteristic curve analyses. RESULTS: The median (interquartile range) age was 60 (51-68) years, and 40% were female. The median tumour size was 4.2 cm and 91.3% had malignant tumours. In all, 27% of the tumours were high stage, 37% high grade, and 63% of the patients underwent partial nephrectomy. There was significant agreement between human and AI scores on linear regression analyses (R ranged from 0.574 to 0.828, all P < 0.001). The AI-generated scores were equivalent or superior to human-generated scores for all examined outcomes including high-grade histology, high-stage tumour, indolent tumour, pathological tumour necrosis, and radical nephrectomy (vs partial nephrectomy) surgical approach. CONCLUSIONS: Fully automated AI-generated C-Index, PADUA, and tumour CSA nephrometry scores are similar to human-generated scores and predict a wide variety of meaningful outcomes. Once validated, our results suggest that AI-generated nephrometry scores could be delivered automatically from a preoperative CT scan to a clinician and patient at the point of care to aid in decision making.


Assuntos
Neoplasias Renais , Tomografia Computadorizada por Raios X , Humanos , Feminino , Neoplasias Renais/patologia , Neoplasias Renais/cirurgia , Neoplasias Renais/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Idoso , Nefrectomia/métodos , Valor Preditivo dos Testes , Inteligência Artificial , Estudos Retrospectivos
3.
Clin Immunol ; 254: 109713, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37516396

RESUMO

Due to unique advantages that allow high-dimensional tissue profiling, we postulated imaging mass cytometry (IMC) may shed novel insights on the molecular makeup of proliferative lupus nephritis (LN). This study interrogates the spatial expression profiles of 50 target proteins in LN and control kidneys. Proliferative LN glomeruli are marked by podocyte loss with immune infiltration dominated by CD45RO+, HLA-DR+ memory CD4 and CD8 T-cells, and CD163+ macrophages, with similar changes in tubulointerstitial regions. Macrophages are the predominant HLA-DR expressing antigen presenting cells with little expression elsewhere, while macrophages and T-cells predominate cellular crescents. End-stage sclerotic glomeruli are encircled by an acellular fibro-epithelial Bowman's space surrounded by immune infiltrates, all enmeshed in fibronectin. Proliferative LN also shows signs indicative of epithelial to mesenchymal plasticity of tubular cells and parietal epithelial cells. IMC enabled proteomics is a powerful tool to delineate the spatial architecture of LN at the protein level.


Assuntos
Nefrite Lúpica , Humanos , Proteômica , Glomérulos Renais/metabolismo , Rim/metabolismo , Citometria por Imagem
4.
Magn Reson Med ; 89(1): 144-160, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36098347

RESUMO

PURPOSE: To assess the effect of respiratory motion and cardiac driven pulsation in renal DWI and to examine asymmetrical velocity-compensated diffusion encoding waveforms for robust ADC mapping in the kidneys. METHODS: The standard monopolar Stejskal-Tanner pulsed gradient spin echo (pgse) and the asymmetric bipolar velocity-compensated (asym-vc) diffusion encoding waveforms were used for coronal renal DWI at 3T. The robustness of the ADC quantification in the kidneys was tested with the aforementioned waveforms in respiratory-triggered and breath-held cardiac-triggered scans at different trigger delays in 10 healthy subjects. RESULTS: The pgse waveform showed higher ADC values in the right kidney at short trigger delays in comparison to longer trigger delays in the respiratory triggered scans when the diffusion gradient was applied in the feet-head (FH) direction. The coefficient of variation over all respiratory trigger delays, averaged over all subjects was 0.15 for the pgse waveform in the right kidney when diffusion was measured in the FH direction; the corresponding coefficient of variation for the asym-vc waveform was 0.06. The effect of cardiac driven pulsation was found to be small in comparison to the effect of respiratory motion. CONCLUSION: Short trigger delays in respiratory-triggered scans can cause higher ADC values in comparison to longer trigger delays in renal DWI, especially in the right kidney when diffusion is measured in the FH direction. The asym-vc waveform can reduce ADC variation due to respiratory motion in respiratory-triggered scans at the cost of reduced SNR compared to the pgse waveform.


Assuntos
Imagem de Difusão por Ressonância Magnética , Rim , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Movimento (Física) , Rim/diagnóstico por imagem , Coração/diagnóstico por imagem , Difusão , Reprodutibilidade dos Testes
5.
NMR Biomed ; 36(6): e4894, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36543742

RESUMO

Here, we describe and assess the potential of 14 newly synthesized imidazole-4,5-dicarboxyamides (I45DCs) for pH and perfusion imaging. A number of these aromatic compounds possess large labile proton chemical shifts (up to 7.7 ppm from water) because of their intramolecular hydrogen bonds and a second labile proton to allow for chemical exchange saturation transfer (CEST) signal ratio-based pH measurements. We have found that the contrast produced is strong for a wide range of substitutions and that the inflection points in the CEST signal ratio versus pH plots used to generate concentration-independent pH maps can be adjusted based on these subsitutions to tune the pH range that can be measured. These I45DC CEST agents have advantages over the triiodobenzenes currently employed for tumor and kidney pH mapping, both preclinically and in initial human studies. Finally, as CEST MRI combined with exogenous contrast has the potential to detect functional changes in the kidneys, we evaluated our highest performing anionic compound (I45DC-diGlu) on a unilateral urinary obstruction mouse model and observed lower contrast uptake in the obstructed kidney compared with the unobstructed kidney and that the unobstructed kidney displayed a pH of ~ 6.5 while the obstructed kidney had elevated pH and an increased range in pH values. Based on this, we conclude that the I45DCs have excellent imaging properties and hold promise for a variety of medical imaging applications, particularly renal imaging.


Assuntos
Meios de Contraste , Prótons , Camundongos , Animais , Humanos , Concentração de Íons de Hidrogênio , Meios de Contraste/química , Imagens de Fantasmas , Imageamento por Ressonância Magnética/métodos , Imidazóis , Imagem de Perfusão
6.
J Magn Reson Imaging ; 53(5): 1432-1443, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33382173

RESUMO

BACKGROUND: Diffusion-weighted MRI (DW-MRI) of the kidneys is a technique that provides information about the microstructure of renal tissue without requiring exogenous contrasts such as gadolinium, and it can be used for diagnosis in cases of renal disease and assessing response-to-therapy. However, physiological motion and large geometric distortions due to main B0 field inhomogeneities degrade the image quality, reduce the accuracy of quantitative imaging markers, and impede their subsequent clinical applicability. PURPOSE: To retrospectively correct for geometric distortion for free-breathing DW-MRI of the kidneys at 3T, in the presence of a nonstatic distortion field due to breathing and bulk motion. STUDY TYPE: Prospective. SUBJECTS: Ten healthy volunteers (ages 29-38, four females). FIELD STRENGTH/SEQUENCE: 3T; DW-MR dual-echo echo-planar imaging (EPI) sequence (10 b-values and 17 directions) and a T2 volume. ASSESSMENT: The distortion correction was evaluated subjectively (Likert scale 0-5) and numerically with cross-correlation between the DW images at b = 0 s/mm2 and a T2 volume. The intravoxel incoherent motion (IVIM) and diffusion tensor (DTI) model-fitting performance was evaluated using the root-mean-squared error (nRMSE) and the coefficient of variation (CV%) of their parameters. STATISTICAL TESTS: Statistical comparisons were done using Wilcoxon tests. RESULTS: The proposed method improved the Likert scores by 1.1 ± 0.8 (P < 0.05), the cross-correlation with the T2 reference image by 0.13 ± 0.05 (P < 0.05), and reduced the nRMSE by 0.13 ± 0.03 (P < 0.05) and 0.23 ± 0.06 (P < 0.05) for IVIM and DTI, respectively. The CV% of the IVIM parameters (slow and fast diffusion, and diffusion fraction for IVIM and mean diffusivity, and fractional anisotropy for DTI) was reduced by 2.26 ± 3.98% (P = 6.971 × 10-2 ), 11.24 ± 26.26% (P = 6.971 × 10-2 ), 4.12 ± 12.91% (P = 0.101), 3.22 ± 0.55% (P < 0.05), and 2.42 ± 1.15% (P < 0.05). DATA CONCLUSION: The results indicate that the proposed Di + MoCo method can effectively correct for time-varying geometric distortions and for misalignments due to breathing motion. Consequently, the image quality and precision of the DW-MRI model parameters improved. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 1.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Rim/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Movimento (Física) , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos
7.
Magn Reson Med ; 83(6): 1940-1948, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31900983

RESUMO

PURPOSE: To evaluate the use of magnetic resonance fingerprinting (MRF) for simultaneous quantification of T1 and T2∗ in a single breath-hold in the kidneys. METHODS: The proposed kidney MRF sequence was based on MRF echo-planar imaging. Thirty-five measurements per slice and overall 4 slices were measured in 15.4 seconds. Group matching was performed for in-line quantification of T1 and T2∗ . Images were acquired in a phantom and 8 healthy volunteers in coronal orientation. To evaluate our approach, region of interests were drawn in the kidneys to calculate mean values and standard deviations of the T1 and T2∗ times. Precision was calculated across multiple repeated MRF scans. Gaussian filtering is applied on baseline images to improve SNR and match stability. RESULTS: T1 and T2∗ times acquired with MRF in the phantom showed good agreement with reference measurements and conventional mapping methods with deviations of less than 5% for T1 and less than 10% for T2∗ . Baseline images in vivo were free of artifacts and relaxation times yielded good agreement with conventional methods and literature (deviation T1:7±4% , T2∗:6±3% ). CONCLUSIONS: In this feasibility study, the proposed renal MRF sequence resulted in accurate T1 and T2∗ quantification in a single breath-hold.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Encéfalo , Humanos , Rim/diagnóstico por imagem , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas
8.
NMR Biomed ; 33(3): e4230, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31856426

RESUMO

This study aims to investigate the feasibility of dynamic hyperpolarized 13 C MR spectroscopic imaging (MRSI) using the SPectroscopic Imaging by exploiting spatiospectral CorrElation (SPICE) technique and an estimation of the spatially resolved conversion constant rate (kpl ). An acquisition scheme comprising a single training dataset and several imaging datasets was proposed considering hyperpolarized 13 C circumstances. The feasibility and advantage of the scheme were investigated in two parts: (a) consistency of spectral basis over time and (b) accuracy of the estimated kpl . The simulations and in vivo experiments support accurate kpl estimation with consistent spectral bases. The proposed method was implemented in an enzyme phantom and via in vivo experiments. In the enzyme phantom experiments, spatially resolved homogeneous kpl maps were observed. In the in vivo experiments, normal diet (ND) mice and high-fat diet (HFD) mice had kpl (s-1 ) values of medullar (ND: 0.0119 ± 0.0022, HFD: 0.0195 ± 0.0005) and cortical (ND: 0.0148 ±0.0023, HFD: 0.0224 ±0.0054) regions which were higher than vascular (ND: 0.0087 ±0.0013, HFD: 0.0132 ±0.0050) regions. In particular, the kpl value in the medullar region exhibited a significant difference between the two diet groups. In summary, the feasibility of using modified SPICE for dynamic hyperpolarized 13 C MRSI was demonstrated via simulations and in vivo experiments. The consistency of spectral bases over time and the accuracy of the estimated kpl values validate the proposed acquisition scheme, which comprises only a single training dataset. The proposed method improved the spatial resolution of dynamic hyperpolarized 13 C MRSI, which could be used for kpl estimation using high signal-to-noise ratio spectral bases.


Assuntos
Algoritmos , Espectroscopia de Ressonância Magnética Nuclear de Carbono-13 , Rim/diagnóstico por imagem , Animais , Dieta Hiperlipídica , Enzimas/metabolismo , Camundongos , Imagens de Fantasmas
9.
J Magn Reson Imaging ; 52(1): 207-216, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31837071

RESUMO

BACKGROUND: Evaluation of kidney function in newborns with hydronephrosis is important for clinical decisions. Dynamic contrast-enhanced (DCE) MRI can provide the necessary anatomical and functional information. Golden angle dynamic radial acquisition and compressed sensing reconstruction provides sufficient spatiotemporal resolution to achieve accurate parameter estimation for functional imaging of kidneys. However, bulk motion during imaging (rigid or nonrigid movement of the subject resulting in signal dropout) remains an unresolved challenge. PURPOSE: To evaluate a motion-compensated (MoCo) DCE-MRI technique for robust evaluation of kidney function in newborns. Our method includes: 1) motion detection, 2) motion-robust image reconstruction, 3) joint realignment of the volumes, and 4) tracer-kinetic (TK) model fitting to evaluate kidney function parameters. STUDY TYPE: Retrospective. SUBJECTS: Eleven newborn patients (ages <6 months, 6 female). FIELD STRENGTH/SEQUENCE: 3T; dynamic "stack-of-stars" 3D fast low-angle shot (FLASH) sequence using a multichannel body-matrix coil. ASSESSMENT: We evaluated the proposed technique in terms of the signal-to-noise ratio (SNR) of the reconstructed images, the presence of discontinuities in the contrast agent concentration time curves due to motion with a total variation (TV) metric and the goodness of fit of the TK model, and the standard variation of its parameters. STATISTICAL TESTS: We used a paired t-test to compare the MoCo and no-MoCo results. RESULTS: The proposed MoCo method successfully detected motion and improved the SNR by 3.3 (P = 0.012) and decreased TV by 0.374 (P = 0.017) across all subjects. Moreover, it decreased nRMSE of the TK model fit for the subjects with less than five isolated bulk motion events in 6 minutes (mean 1.53, P = 0.043), but not for the subjects with more frequent events or no motion (P = 0.745 and P = 0.683). DATA CONCLUSION: Our results indicate that the proposed MoCo technique improves the image quality and accuracy of the TK model fit for subjects who present isolated bulk motion events. LEVEL OF EVIDENCE: 3 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2020;52:207-216.


Assuntos
Meios de Contraste , Rim , Imageamento por Ressonância Magnética , Criança , Pré-Escolar , Feminino , Humanos , Imageamento Tridimensional , Lactente , Recém-Nascido , Rim/diagnóstico por imagem , Movimento (Física) , Estudos Retrospectivos
10.
J Am Soc Nephrol ; 28(9): 2564-2570, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28784699

RESUMO

Magnetic resonance imaging (MRI) has been used for many years for anatomic evaluation of the kidney. Recently developed methods attempt to go beyond anatomy to give information about the health and function of the kidneys. Several methods, including diffusion-weighted MRI, renal blood oxygen level-dependent MRI, renal MR elastography, and renal susceptibility imaging, show promise for providing unique insight into kidney function and severity of fibrosis. However, substantial limitations in accuracy and practicality limit the immediate clinical application of each method. Further development and improvement are necessary to achieve the ideal of a noninvasive image-based measure of renal fibrosis. Our brief review provides a short explanation of these emerging MRI methods and outlines the promising initial results obtained with each as well as current limitations and barriers to clinical implementation.


Assuntos
Rim/diagnóstico por imagem , Rim/patologia , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética , Técnicas de Imagem por Elasticidade , Fibrose , Humanos , Rim/irrigação sanguínea , Oxigênio/sangue
11.
Am J Kidney Dis ; 65(1): 41-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25022339

RESUMO

BACKGROUND: Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is a potentially powerful tool for analysis of kidney structure and function. The ability to measure functional and hypofunctional tissues could provide important information in groups at risk for chronic kidney disease (CKD), such as the elderly. STUDY DESIGN: Observational study with a cross-sectional design. SETTING & PARTICIPANTS: 493 volunteers (aged 72-94 years; 278 women; mean estimated glomerular filtration rate [eGFR], 67±15mL/min/1.73m(2); 40% with CKD) in the Age, Gene/Environment Susceptibility (AGES)-Reykjavik Study. PREDICTOR: DCE-MRI kidney segmentation data. OUTCOMES & MEASUREMENTS: eGFR, urine albumin-creatinine ratio (ACR), and risk factors for and complications of CKD. RESULTS: After adjustment for age, sex, and height, eGFR was related to kidney volume (ΔR²=0.19; P<0.001), cortex volume (ΔR²=0.14; P<0.001), medulla volume (ΔR²=0.18; P<0.001), and volume percentages of fibrosis (ΔR²=0.03; P<0.001) and fat (ΔR²=0.01; P=0.03). In similarly adjusted models, log(ACR) was related to kidney volume (ΔR²=0.02; P<0.001) and fibrosis volume percentage (ΔR²=0.03; P<0.001). Using multivariable regression models adjusted for eGFR, ACR, age, sex, and height, kidney volume was related positively to body mass index (B=29.9±2.1[SE]mL; P<0.001), smoking (B=19.7±7.7mL; P=0.01), and diabetes mellitus (B=14.8±7.1mL; P=0.04) and negatively to hematocrit (B=-4.4±2.1mL; P=0.04 [model R²=0.72; P<0.001]); relations were per 1-SD greater value of the variable. Fibrosis volume percentage was associated positively with body mass index (B=0.28±0.03; P<0.001), cardiac output (B=0.15±0.03; P<0.001), and heart rate (B=0.08±0.03; P=0.01) and negatively with hematocrit (B=-0.07±0.3; P=0.02) and augmentation index (B=-0.06±0.03; P=0.04 [model R²=0.49; P<0.001]); again, relations are per 1-SD greater value of the variable. LIMITATIONS: Automatic segmentations were not validated by histology. The limited age range prevented meaningful interpretation of age effects on measured data or the automatic segmentation procedure. CONCLUSIONS: Kidney volume, cortex volume, and hypofunctional volume fraction assessed by DCE-MRI may provide information about CKD risk and prognosis beyond that provided by eGFR and urine ACR.


Assuntos
Rim , Imageamento por Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Albuminúria/diagnóstico , Índice de Massa Corporal , Creatinina/urina , Estudos Transversais , Feminino , Taxa de Filtração Glomerular , Humanos , Aumento da Imagem , Rim/patologia , Rim/fisiopatologia , Masculino , Tamanho do Órgão , Valor Preditivo dos Testes , Prognóstico , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/epidemiologia , Insuficiência Renal Crônica/fisiopatologia , Fatores de Risco , Estados Unidos/epidemiologia
12.
Front Physiol ; 15: 1327407, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38384795

RESUMO

Introduction: Magnetic resonance elastography (MRE) is a non-invasive method to quantify biomechanical properties of human tissues. It has potential in diagnosis and monitoring of kidney disease, if established in clinical practice. The interplay of flow and volume changes in renal vessels, tubule, urinary collection system and interstitium is complex, but physiological ranges of in vivo viscoelastic properties during fasting and hydration have never been investigated in all gross anatomical segments simultaneously. Method: Ten healthy volunteers underwent two imaging sessions, one following a 12-hour fasting period and the second after a drinking challenge of >10 mL per kg body weight (60-75 min before the second examination). High-resolution renal MRE was performed using a novel driver with rotating eccentric mass placed at the posterior-lateral wall to couple waves (50 Hz) to the kidney. The biomechanical parameters, shear wave speed (cs in m/s), storage modulus (Gd in kPa), loss modulus (Gl in kPa), phase angle (Υ=2πatanGlGd) and attenuation (α in 1/mm) were derived. Accurate separation of gross anatomical segments was applied in post-processing (whole kidney, cortex, medulla, sinus, vessel). Results: High-quality shear waves coupled into all gross anatomical segments of the kidney (mean shear wave displacement: 163 ± 47 µm, mean contamination of second upper harmonics <23%, curl/divergence: 4.3 ± 0.8). Regardless of the hydration state, median Gd of the cortex and medulla (0.68 ± 0.11 kPa) was significantly higher than that of the sinus and vessels (0.48 ± 0.06 kPa), and consistently, significant differences were found in cs, Υ, and Gl (all p < 0.001). The viscoelastic parameters of cortex and medulla were not significantly different. After hydration sinus exhibited a small but significant reduction in median Gd by -0.02 ± 0.04 kPa (p = 0.01), and, consequently, the cortico-sinusoidal-difference in Gd increased by 0.04 ± 0.07 kPa (p = 0.05). Only upon hydration, the attenuation in vessels became lower (0.084 ± 0.013 1/mm) and differed significantly from the whole kidney (0.095 ± 0.007 1/mm, p = 0.01). Conclusion: High-resolution renal MRE with an innovative driver and well-defined 3D segmentation can resolve all renal segments, especially when including the sinus in the analysis. Even after a prolonged hydration period the approach is sensitive to small hydration-related changes in the sinus and in the cortico-sinusoidal-difference.

13.
Diagnostics (Basel) ; 14(10)2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38786292

RESUMO

Congenital anomalies affecting the kidneys present significant challenges in pediatric nephrology, needing precise methods for assessing renal function and guiding therapeutic intervention. Bedside Schwartz formula with the cystatin-C-based Full Age Spectrum formula and Chronic Kidney Disease in Children (CKiD) U 25 formula used in estimating glomerular filtration rate (eGFR) and also to assess if the eGFR in association with kidney length percentiles can be a monitoring parameter for the progression of chronic kidney disease in children with congenital anomalies of the kidney and urinary tract (CAKUT). A total of 64 pediatric patients (median age at diagnostic was 12 months with an interquartile range of 2 to 60) were diagnosed with congenital anomalies in the kidney and urinary tract between June 2018 and May 2023 at "Louis Turcanu" Emergency Hospital for Children in Timisoara, Romania. Baseline characteristics, CAKUT types, associated pathologies, CKD staging, and eGFR using creatinine and cystatin C were analyzed. The mean age at the moment of examination was 116.50 months; (65, 180). Chronic kidney disease staging revealed a predominance of patients in CKD stages G1 and A1. Analysis of eGFR methods revealed a small mean difference between eGFR estimated by creatinine and cystatin C, with a moderate-strong positive correlation observed between the eGFR and ultrasound parameters. Using cystatin-C-based formulas for eGFR, in conjunction with ultrasound measurements, may offer reliable insights into renal function in pediatric patients with congenital anomalies affecting the kidney and urinary tract. However, the economic aspect must be taken into consideration because cystatin C determination is approximately eight times more expensive than that of creatinine. An interdisciplinary approach is crucial for managing patients with CAKUT.

14.
Nephrol Dial Transplant ; 28(5): 1150-6, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23291364

RESUMO

BACKGROUND: The clinical use of iodinated radiocontrast agents or gadolinium for renal perfusion imaging is limited in the presence of renal dysfunction. We have previously demonstrated the feasibility of hemodynamic response imaging (HRI), a functional magnetic resonance imaging (MRI) method combined with hypercapnia and hypercapnic-hyperoxia, for monitoring changes in liver perfusion and hemodynamics. The aim of the present study was to evaluate the utility of HRI for monitoring changes in renal perfusion and hemodynamics. METHODS: Renal HRI maps were acquired during graded hypercapnia (95% air + 5% CO2) and hypercapnic-hyperoxia (95% O2 + 5% CO2) in control mice. The utility of HRI for monitoring changes in renal perfusion and oxygenation was evaluated using pharmacological inhibition of nitric oxide synthase and cycloxygenase as well as in rhabdomyolysis-induced acute kidney injury (AKI) in mice. HRI results were further interpreted using Doppler ultrasound (US). RESULTS: Renal HRI maps revealed pronounced signal-intensity changes in response to both hypercapnia and hypercapnic-hyperoxia, reflecting intense vascular reactivity. These changes were significantly attenuated following the pharmacological intervention and during AKI, corresponding with hampered perfusion dynamics, as confirmed by Doppler US. CONCLUSIONS: The applicability of the non-invasive HRI method suggests its potential use for the evaluation of renal perfusion and vascular reactivity, excluding the need for contrast-agent administration.


Assuntos
Injúria Renal Aguda/patologia , Hemodinâmica , Hipercapnia/patologia , Imageamento por Ressonância Magnética , Rabdomiólise/complicações , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/metabolismo , Animais , Meios de Contraste , Modelos Animais de Doenças , Inibidores Enzimáticos/farmacologia , Camundongos , Óxido Nítrico Sintase/antagonistas & inibidores , Óxido Nítrico Sintase/metabolismo , Oxigênio/metabolismo , Prostaglandina-Endoperóxido Sintases/química , Prostaglandina-Endoperóxido Sintases/metabolismo , Ultrassonografia Doppler
15.
Mol Imaging Biol ; 25(1): 3-17, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-34779969

RESUMO

In recent years, the demand for non-destructive deep-tissue imaging modalities has led to interest in multiphoton endoscopy. In contrast to bench top systems, multiphoton endoscopy enables subcellular resolution imaging in areas not reachable before. Several groups have recently presented their development towards the goal of producing user friendly plug and play system, which could be used in biological research and, potentially, clinical applications. We first present the technological challenges, prerequisites, and solutions in two-photon endoscopic systems. Secondly, we focus on the applications already found in literature. These applications mostly serve as a quality check of the built system, but do not answer a specific biomedical research question. Therefore, in the last part, we will describe our vision on the enormous potential applicability of adult two-photon endoscopic systems in biological and clinical research. We will thus bring forward the concept that two-photon endoscopy is a sine qua non in bringing this technique to the forefront in clinical applications.


Assuntos
Pesquisa Biomédica , Endoscopia , Endoscopia/métodos , Diagnóstico por Imagem/métodos , Fótons
16.
Adv Kidney Dis Health ; 30(5): 407-416, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-38097331

RESUMO

While autosomal dominant polycystic kidney disease (ADPKD) is a dichotomous diagnosis, substantial variability in disease severity exists. Identification of inherited risk through family history, genetic testing, and environmental risk factors through clinical assessment are important components of risk assessment for optimal management of patients with ADPKD. Genetic testing is especially helpful in cases with diagnostic uncertainty, particularly in cases with no apparent family history, in young cases (age less than 25 years) where a definitive diagnosis is sought, or in atypical presentations with early, severe, or discordant findings. Currently, risk assessment in ADPKD may be performed with the use of age-adjusted estimated glomerular filtration rate thresholds, evidence of rapid estimated glomerular filtration rate decline on serial measurements, age- and height-adjusted total kidney volume by Mayo Clinic Imaging Classification, or evidence of early hypertension and urological complications combined with PKD1 or PKD2 mutation class; however, caveats exist with each of these approaches. Fine-tuning of risk stratification with advanced imaging features and biomarkers is the subject of research but is not yet ready for general clinical practice. While conservative treatment strategies will be advised for all patients, those with the greatest rate of disease progression will have the most benefit from aggressive disease-modifying therapy. In this narrative review, we will summarize the evidence behind the clinical assessment and risk stratification of patients with ADPKD.


Assuntos
Rim Policístico Autossômico Dominante , Insuficiência Renal , Humanos , Adulto , Rim Policístico Autossômico Dominante/complicações , Canais de Cátion TRPP/genética , Mutação , Rim , Insuficiência Renal/complicações
17.
J Am Coll Radiol ; 19(5): 637-646, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35346619

RESUMO

PURPOSE: The aim of this study was to scale structured report templates categorizing actionable renal findings across health systems and create a centralized registry of patient and report data. METHODS: In January 2017, three academic radiology departments agreed to prospectively include identical structured templates categorizing the malignant likelihood of renal findings in ≥90% of all adult ultrasound, MRI, and CT reports, a new approach for two sites. Between November 20, 2017, and September 30, 2019, deidentified HL7 report data were transmitted to a centralized ACR registry. An automated algorithm extracted categories. Radiologists were requested to addend reports with missing or incomplete templates after the first month. Separately, each site submitted patient sociodemographic and clinical data 12 months before and at least 3 months after enrollment. RESULTS: A total of 164,982 eligible radiology reports were transmitted to the registry; 4,159 (2.5%) were excluded because of missing categories or radiologist names. The final cohort included 160,823 examinations on 102,619 unique patients. Mean template use before and after addendum requests was 99.3% and 99.9% at SITE1, 86.5% and 94.6% at SITE2, and 91.4% and 96.0% at SITE3. Matching patient sociodemographic and clinical data were obtained on 96.9% of reports from SITE1, 94.2% from SITE2, and 96.0% from SITE3. Regulatory, cultural, and technology barriers to the creation of a multisite registry were identified. CONCLUSIONS: Barriers to the adoption of unified structured report templates for actionable kidney findings can be addressed. Deidentified report and patient data can be securely transmitted to an external registry. These data can facilitate the collection of diverse evidence-based population imaging outcomes.


Assuntos
Serviço Hospitalar de Radiologia , Sistemas de Informação em Radiologia , Adulto , Humanos , Rim , Imageamento por Ressonância Magnética , Sistema de Registros
18.
Mol Cell Pediatr ; 9(1): 13, 2022 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-35788444

RESUMO

BACKGROUND: Chronic kidney disease (CKD) is a global burden affecting both children and adults. Novel imaging modalities hold great promise to visualize and quantify structural, functional, and molecular organ damage. The aim of the study was to visualize and quantify murine renal vasculature using label-free raster scanning optoacoustic mesoscopy (RSOM) in explanted organs from mice with renal injury. MATERIAL AND METHODS: For the experiments, freshly bisected kidneys of alpha 8 integrin knock-out (KO) and wildtype mice (WT) were used. A total of n=7 female (n=4 KO, n=3 WT) and n=6 male animals (n=2 KO, n=4 WT) aged 6 weeks were examined with RSOM optoacoustic imaging systems (RSOM Explorer P50 at SWL 532nm and/or ms-P50 imaging system at 532 nm, 555 nm, 579 nm, and 606 nm). Images were reconstructed using a dedicated software, analyzed for size and vascular area and compared to standard histologic sections. RESULTS: RSOM enabled mapping of murine kidney size and vascular area, revealing differences between kidney sizes of male (m) and female (f) mice (merged frequencies (MF) f vs. m: 52.42±6.24 mm2 vs. 69.18±15.96 mm2, p=0.0156) and absolute vascular area (MF f vs. m: 35.67±4.22 mm2 vs. 49.07±13.48 mm2, p=0.0036). Without respect to sex, the absolute kidney area was found to be smaller in knock-out (KO) than in wildtype (WT) mice (WT vs. KO: MF: p=0.0255) and showed a similar trend for the relative vessel area (WT vs. KO: MF p=0.0031). Also the absolute vessel areas of KO compared to WT were found significantly different (MF p=0.0089). A significant decrease in absolute vessel area was found in KO compared to WT male mice (MF WT vs. KO: 54.37±9.35 mm2 vs. 34.93±13.82 mm2, p=0.0232). In addition, multispectral RSOM allowed visualization of oxygenated and deoxygenated parenchymal regions by spectral unmixing. CONCLUSION: This study demonstrates the capability of RSOM for label-free visualization of differences in vascular morphology in ex vivo murine renal tissue at high resolution. Due to its scalability optoacoustic imaging provides an emerging modality with potential for further preclinical and clinical imaging applications.

19.
Adv Mater ; 32(17): e1908530, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32141674

RESUMO

Photoacoustic (PA) imaging agents detect disease tissues and biomarkers with increased penetration depth and enhanced spatial resolution relative to traditional optical imaging, and thus hold great promise for clinical applications. However, existing PA imaging agents often encounter the issues of slow body excretion and low-signal specificity, which compromise their capability for in vivo detection. Herein, a fluoro-photoacoustic polymeric renal reporter (FPRR) is synthesized for real-time imaging of drug-induced acute kidney injury (AKI). FPRR simultaneously turns on both near-infrared fluorescence (NIRF) and PA signals in response to an AKI biomarker (γ-glutamyl transferase) with high sensitivity and specificity. In association with its high renal clearance efficiency (78% at 24 h post-injection), FPRR can detect cisplatin-induced AKI at 24 h post-drug treatment through both real-time imaging and optical urinalysis, which is 48 h earlier than serum biomarker elevation and histological changes. More importantly, the deep-tissue penetration capability of PA imaging results in a signal-to-background ratio that is 2.3-fold higher than NIRF imaging. Thus, the study not only demonstrates the first activatable PA probe for real-time sensitive imaging of kidney function at molecular level, but also highlights the polymeric probe structure with high renal clearance.


Assuntos
Injúria Renal Aguda/diagnóstico por imagem , Corantes Fluorescentes/química , Técnicas Fotoacústicas/métodos , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/metabolismo , Injúria Renal Aguda/patologia , Animais , Biomarcadores/sangue , Linhagem Celular , Núcleo Celular/química , Núcleo Celular/metabolismo , Cisplatino/toxicidade , Creatinina/sangue , Corantes Fluorescentes/metabolismo , Humanos , Rim/diagnóstico por imagem , Rim/patologia , Camundongos , Microscopia de Fluorescência , Razão Sinal-Ruído , Espectrofotometria Ultravioleta , gama-Glutamiltransferase/sangue , gama-Glutamiltransferase/metabolismo
20.
J Nucl Med ; 60(9): 1325-1332, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30796169

RESUMO

An unmet need for the clinical management of chronic kidney disease is a predictive tool of kidney function during the first decade of the disease, when there is silent loss of glomerular function. The objective of this study was to demonstrate receptor-mediated binding of tilmanocept to CD206 within the kidney and provide evidence of kinetic sensitivity of this binding to renal function. Methods: Rats were positioned in a PET scanner with the liver and kidneys within the field of view. After an intravenous injection of 68Ga-IRDye800-tilmanocept, using 1 of 2 scaled molar doses (0.02 nmol/g, n = 5; or 0.10 nmol/g, n = 5), or coinjection (n = 3) of 68Ga-IRDye800-tilmanocept (0.10 nmol/g) and unlabeled tilmanocept (5.0 nmol/g), or a negative control, 68Ga-IRDye800-DTPA-galactosyl-dextran (0.02 nmol/g, n = 5), each animal was imaged for 20 min followed by a whole-body scan. Frozen kidney sections were stained for podocytes and CD206 using immunofluorescence. Molecular imaging of diabetic db/db mice (4.9 wk, n = 6; 7.3 wk, n = 4; 13.3 wk, n = 6) and nondiabetic db/m mice (n = 6) was performed with fluorescence-labeled 99mTc-tilmanocept (18.5 MBq, 2.6 nmol). Thirty minutes after injection, blood, liver, kidneys, and urine were assayed for radioactivity. Renal time-activity curves were generated. Results: Rat PET whole-body images and time-activity curves of 68Ga-IRDye800-tilmanocept demonstrated receptor-mediated renal accumulation with evidence of glomerular uptake. Activity within the renal cortex persisted during the 40-min study. Histologic examination demonstrated colocalization of CD206 and IRDye800-tilmanocept within the glomerulus. The glomerular accumulation of the coinjection and the negative control studies were significantly less than the CD206-targeted agent. The db/db mice displayed a multiphasic renal time-activity curve with high urinary bladder accumulation; the nondiabetic mice exhibited renal uptake curves dominated by a single phase with low bladder accumulation. Conclusion: This study demonstrated receptor-mediated binding to the glomerular mesangial cells and kinetic sensitivity of tilmanocept to chronic renal disease. Given the role of mesangial cells during the progression of diabetic nephropathy, PET or SPECT renal imaging with radiolabeled tilmanocept may provide a noninvasive quantitative assessment of glomerular function.


Assuntos
Dextranos/farmacocinética , Glomérulos Renais/efeitos dos fármacos , Glomérulos Renais/diagnóstico por imagem , Células Mesangiais/metabolismo , Tomografia por Emissão de Pósitrons , Pentetato de Tecnécio Tc 99m/análogos & derivados , Tomografia Computadorizada de Emissão de Fóton Único , Animais , Imuno-Histoquímica , Injeções Intravenosas , Cinética , Lectinas Tipo C/metabolismo , Fígado/metabolismo , Linfonodos/patologia , Masculino , Receptor de Manose , Lectinas de Ligação a Manose/metabolismo , Camundongos , Microscopia de Fluorescência , Imagem Molecular , Compostos Radiofarmacêuticos/farmacocinética , Ratos , Receptores de Superfície Celular/metabolismo , Biópsia de Linfonodo Sentinela , Pentetato de Tecnécio Tc 99m/farmacocinética , Distribuição Tecidual , Imagem Corporal Total
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA