Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Methods Cell Biol ; 174: 93-111, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36710054

RESUMO

Mitophagy is a finely regulated mechanism through which eukaryotic cells selectively dispose of supernumerary, permeabilized or otherwise damaged mitochondria through lysosomal degradation. Dysfunctional mitochondria are prone to release potentially cytotoxic factors including reactive oxygen species (ROS) and caspase activators, such as cytochrome c, somatic (CYCS). Thus, proficient mitophagic responses mediate prominent cytoprotective functions. Moreover, the rapid degradation of permeabilized mitochondria limits the release of mitochondrial components that may drive inflammatory reactions, such as mitochondrial DNA (mtDNA) and transcription factor A, mitochondrial (TFAM), implying that mitophagy also mediates potent anti-inflammatory effects. Here, we detail a simple, flow cytometry-assisted protocol for the specific measurement of mitophagic responses as driven by radiation therapy (RT) in mouse hormone receptor (HR)+ mammary carcinoma TS/A cells. With some variations, this method - which relies on the mitochondria-restricted expression of a fluorescent reporter that is sensitive to pH and hence changes excitation wavelength within lysosomes (mt-mKeima) - can be adapted to a variety of human and mouse cancer cell lines and/or straightforwardly implemented on fluorescence microscopy platforms.


Assuntos
Mitofagia , Neoplasias , Camundongos , Humanos , Animais , Mitofagia/genética , Mitocôndrias/metabolismo , Linhagem Celular , DNA Mitocondrial , Espécies Reativas de Oxigênio/metabolismo , Autofagia , Neoplasias/metabolismo
2.
Methods Cell Biol ; 180: 1-13, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37890924

RESUMO

Image-guided radiation therapy (IGRT) platforms for preclinical research represent an important advance for radiation research. IGRT-based platforms more accurately model the delivery of therapeutic ionizing radiation as delivered in clinical practice which permits more translationally and clinically relevant radiation biology research. Fundamentally, IGRT allows for precise delivery of ionizing radiation in order to (1) ensure that the tumor and/or target of interest is adequately covered by the prescribed radiation dose, and (2) to minimize the radiation dose delivered to adjacent nontargeted or normal tissues. Here, we describe the techniques and outline a general workflow employed for IGRT in preclinical in vivo tumor models.


Assuntos
Neoplasias , Radioterapia Guiada por Imagem , Humanos , Radioterapia Guiada por Imagem/métodos , Neoplasias/radioterapia , Fluxo de Trabalho
3.
Phys Med Biol ; 67(13)2022 06 29.
Artigo em Inglês | MEDLINE | ID: mdl-35679845

RESUMO

Objective.Dual energy computed tomography (DECT) has been shown to provide additional image information compared to conventional CT and has been used in clinical routine for several years. The objective of this work is to present a DECT implementation for a Small Animal Radiation Research Platform (SARRP) and to verify it with a quantitative analysis of a material phantom and a qualitative analysis with anex-vivomouse measurement.Approach.For dual energy imaging, two different spectra are required, but commercial small animal irradiators are usually not optimized for DECT. We present a method that enables dual energy imaging on a SARRP with sequential scanning and an Empirical Dual Energy Calibration (EDEC). EDEC does not require the exact knowledge of spectra and attenuation coefficients; instead, it is based on a calibration. Due to the SARRP geometry and reconstruction algorithm, the calibration is done using an artificial CT image based on measured values. The calibration yields coefficients to convert the measured images into material decomposed images.Main results.To analyze the method quantitatively, the electron density and the effective atomic number of a material phantom were calculated and compared with theoretical values. The electron density showed a maximum deviation from the theoretical values of less than 5% and the atomic number of slightly more than 6%. For use in mice, DECT is particularly useful in distinguishing iodine contrast agent from bone. A material decomposition of anex-vivomouse with iodine contrast agent was material decomposed to show that bone and iodine can be distinguished and iodine-corrected images can be calculated.Significance.DECT is capable of calculating electron density images and effective atomic number images, which are appropriate parameters for quantitative analysis. Furthermore, virtual monochromatic images can be obtained for a better differentiation of materials, especially bone and iodine contrast agent.


Assuntos
Meios de Contraste , Iodo , Animais , Calibragem , Camundongos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos
4.
Z Med Phys ; 32(3): 261-272, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35370028

RESUMO

In the field of preclinical radiotherapy, many new developments were driven by technical innovations. To make research of different groups comparable in that context and reliable, high quality has to be maintained. Therefore, standardized protocols and programs should be used. Here we present a guideline for a comprehensive and efficient quality assurance program for an image-guided small animal irradiation system, which is meant to test all the involved subsystems (imaging, treatment planning, and the irradiation system in terms of geometric accuracy and dosimetric aspects) as well as the complete procedure (end-to-end test) in a time efficient way. The suggestions are developed on a Small Animal Radiation Research Platform (SARRP) from Xstrahl (Xstrahl Ltd., Camberley, UK) and are presented together with proposed frequencies (from monthly to yearly) and experiences on the duration of each test. All output and energy related measurements showed stable results within small variation. Also, the motorized parts (couch, gantry) and other geometrical alignments were very stable. For the checks of the imaging system, the results are highly dependent on the chosen protocol and differ according to the settings. We received nevertheless stable and comparably good results for our mainly used protocol. All investigated aspects of treatment planning were exactly fulfilled and also the end-to-end test showed satisfying values. The mean overall time we needed for our checks to have a well monitored machine is less than two hours per month.


Assuntos
Radiometria , Radioterapia Guiada por Imagem , Animais , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos
5.
Int J Radiat Biol ; : 1-10, 2022 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-35467478

RESUMO

PURPOSE: A small animal radiation research platform (SARRP) equipped with a miniature beam system, an image-guided positioning system, and a dose planning system was used to develop and evaluate a mouse model of radiation-induced temporomandibular damage. METHODS: Left jaw disks of adult male C57BL/6 mice and C3H mice were targeted using the SARRP for image-guided irradiation. The total radiation dose was 75 Gy. Experiment 1 (Scoping study): Mice in the C57BL/6 mouse test and control groups were sacrificed at 1, 3, 6, 9, 12, 15, and 18 weeks after irradiation, whereas mice in the C3H test and control groups were sacrificed at 1, 3, 6, 9, and 12 weeks after irradiation. Experiment 2 (Full -scale validation study): Mice in the C57BL/6 mouse test and control groups were sacrificed at 1, 3 and 6 weeks after irradiation. Histopathological analysis of the temporomandibular skeletal muscle in each group was performed using hematoxylin and eosin (H&E) and Masson staining; the temporal mandibular bone was examined through H&E staining. RESULTS: SARRP delivered the rated dose to the temporomandibular joints of C57BL/6 and C3H mice. C3H and C57BL/6 mice in the test group showed different degrees of osteocytic necrosis and osteoporosis at different time points. H&E staining of skeletal muscle tissue showed slight fibrosis in the C57BL/6 test at 3 and 6 weeks time point. CONCLUSION: We established a model of radiation-induced damage in the temporomandibular joint of C57BL/6 mice and demonstrated that the observed physiological and histological changes correspond to radiation damage observed in humans. Furthermore, the SARRP can deliver precise radiation doses.

6.
Methods Cell Biol ; 172: 145-161, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36064221

RESUMO

It is now clear that radiation therapy (RT) can be delivered in doses and according to fractionation schedules that actively elicit immunostimulatory effects. While such effects are often sufficient to drive potent anticancer immunity culminating with systemic disease eradication, the immunostimulatory activity of RT stands out as a promising combinatorial partner for bona fide immunotherapeutics including immune checkpoint inhibitors (ICIs). Accumulating preclinical and clinical evidence indicates that the secretion of type I interferon (IFN) by irradiated cancer cells is a sine qua non for RT to initiate ICI-actionable tumor-targeting immune responses. Here, we detail a simple protocol to quantitatively assess type I IFN responses in irradiated mouse hormone receptor (HR)+ TS/A cells by RT-PCR. With minimal variations, the same technique can be straightforwardly adapted to quantify type I IFN-associated transcriptional responses in a variety of human and mouse cancer cells maintained in vitro.


Assuntos
Neoplasias , Animais , Humanos , Camundongos , Neoplasias/genética , Neoplasias/radioterapia , Reação em Cadeia da Polimerase Via Transcriptase Reversa
7.
Front Pharmacol ; 12: 785165, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34912229

RESUMO

[This corrects the article DOI: 10.3389/fphar.2020.587970.].

8.
Cancers (Basel) ; 13(22)2021 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-34830813

RESUMO

Pancreatic ductal adenocarcinoma (PDAC) is one of the most lethal human cancers. Innovative treatment concepts may enhance oncological outcome. Clinically relevant tumor models are essential in developing new therapeutic strategies. In the present study, we used two human PDAC cell lines for an orthotopic xenograft mouse model and compared treatment characteristics between this in vivo tumor model and PDAC patients. Tumor-bearing mice received stereotactic high-precision irradiation using arc technique after 3D-treatment planning. Induction of DNA damage in tumors and organs at risk (OARs) was histopathologically analyzed by the DNA damage marker γH2AX and compared with results after unprecise whole-abdomen irradiation. Our mouse model and preclinical setup reflect the characteristics of PDAC patients and clinical RT. It was feasible to perform stereotactic high-precision RT after defining tumor and OARs by CT imaging. After stereotactic RT, a high rate of DNA damage was mainly observed in the tumor but not in OARs. The calculated dose distributions and the extent of the irradiation field correlate with histopathological staining and the clinical example. We established and validated 3D-planned stereotactic RT in an orthotopic PDAC mouse model, which reflects the human RT. The efficacy of the whole workflow of imaging, treatment planning, and high-precision RT was proven by longitudinal analysis showing a significant improved survival. Importantly, this model can be used to analyze tumor regression and therapy-related toxicity in one model and will allow drawing clinically relevant conclusions.

9.
Phys Med ; 71: 168-175, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32163885

RESUMO

For the small animal radiation research platform (SARRP) with X-ray beams in the medium energy range (tube operating voltage at 220 kVp), reference dosimetry is based on the AAPM TG-61 recommendations following the in-phantom method. The objective of this study was to evaluate the feasibility of the Fricke solution as a dosimeter to determine the absorbed dose to water. Feasibility studies at this X-ray energy range are not widely available. We evaluated the accuracy, dose linearity and dose rate dependence in a comparison with an NE 2571 Farmer ionization chamber (IC) and measurements in water. The G(Fe3+) factor was calculated from the curve fitting of the chemical yields for two radioactive sources (192Ir and 60Co) and one X-ray system with a tube operating at 150 and 250 kVp. The same methodology was followed for the dependence of the G(Fe3+) value on the energy and the dose agreement assessment for 180 and 200 kVp in the SARRP. The Fricke system exhibits a good linear response over the range of 5-70 Gy and an accuracy better than 2% for a 2 Gy/min dose rate. The dose rate dependence is smaller than 1% for dose rates greater than 1 Gy/min. The dependence of the G(Fe3+) value on the energy is smaller than 0.41%, with dose agreements better than 2%. The feasibility of the dosimeter for measurements at high doses and high dose rates makes it a suitable tool for dosimetric verifications in several preclinical irradiation configurations.


Assuntos
Radiometria/instrumentação , Radiometria/métodos , Algoritmos , Animais , Calibragem , Radioisótopos de Cobalto , Estudos de Viabilidade , Compostos Ferrosos , Radioisótopos de Irídio , Modelos Lineares , Imagens de Fantasmas , Dosímetros de Radiação , Reprodutibilidade dos Testes , Soluções , Incerteza , Raios X
10.
Int J Radiat Biol ; 94(6): 597-606, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29701998

RESUMO

PURPOSE: The main objective of radiobiology is to establish links between doses and radiation-induced biological effects. In this context, well-defined dosimetry protocols are crucial to the determination of experimental protocols. This work proposes a new dosimetry protocol for cell irradiation in a SARRP and shows the importance of the modification of some parameters defined in dosimetry protocol for physical dose and biological outcomes. MATERIALS AND METHODS: Once all parameters of the configuration were defined, dosimetry measurements with ionization chambers and EBT3 films were performed to evaluate the dose rate and the attenuation due to the cell culture medium. To evaluate the influence of changes in cell culture volume and/or additional filtration, 6-well plates containing EBT3 films with water were used to determine the impact on the physical dose at 80 kV. Then, experiments with the same irradiation conditions were performed by replacing EBT3 films by HUVECs. The biological response was assessed using clonogenic assay. RESULTS: Using a 0.15 mm copper filter lead to a variation of +1% using medium thickness of 0.104 cm to -8% using a medium thickness of 0.936 cm on the physical dose compare to the reference condition (0.313 cm). For the 1 mm aluminum filter, a variation of +8 to -40% for the same medium thickness conditions has been observed. Cells irradiated in the same conditions showed significant differences in survival fraction, corroborating the effects of dosimetric changes on physical dose. CONCLUSIONS: This work shows the importance of dosimetry in radiobiology studies and the need of an accurate description of the dosimetry protocol used for irradiation.


Assuntos
Radiometria/instrumentação , Desenho de Equipamento , Células Endoteliais da Veia Umbilical Humana/citologia , Células Endoteliais da Veia Umbilical Humana/efeitos da radiação , Humanos , Raios X
11.
Radiat Oncol ; 12(1): 204, 2017 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-29282134

RESUMO

BACKGROUND: Preclinical radiation biology has become increasingly sophisticated due to the implementation of advanced small animal image guided radiation platforms into laboratory investigation. These small animal radiotherapy devices enable state-of-the-art image guided therapy (IGRT) research to be performed by combining high-resolution cone beam computed tomography (CBCT) imaging with an isocentric irradiation system. Such platforms are capable of replicating modern clinical systems similar to those that integrate a linear accelerator with on-board CBCT image guidance. METHODS: In this study, we present a dosimetric evaluation of the small animal radiotherapy research platform (SARRP, Xstrahl Inc.) focusing on small field dosimetry. Physical dosimetry was assessed using ion chamber for calibration and radiochromic film, investigating the impact of beam focus size on the dose rate output as well as beam characteristics (beam shape and penumbra). Two film analysis tools) have been used to assess the dose output using the 0.5 mm diameter aperture. RESULTS: Good agreement (between 1.7-3%) was found between the measured physical doses and the data provided by Xstrahl for all apertures used. Furthermore, all small field dosimetry data are in good agreement for both film reading methods and with our Monte Carlo simulations for both focal spot sizes. Furthermore, the small focal spot has been shown to produce a more homogenous beam with more stable penumbra over time. CONCLUSIONS: FilmQA Pro is a suitable tool for small field dosimetry, with a sufficiently small sampling area (0.1 mm) to ensure an accurate measurement. The electron beam focus should be chosen with care as this can potentially impact on beam stability and reproducibility.


Assuntos
Tomografia Computadorizada de Feixe Cônico/instrumentação , Imagens de Fantasmas , Radiobiologia , Planejamento da Radioterapia Assistida por Computador/instrumentação , Animais , Método de Monte Carlo
12.
Radiother Oncol ; 124(3): 475-481, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28697853

RESUMO

BACKGROUND AND PURPOSE: To evaluate the impact of ATR inhibition using AZD6738 in combination with radiotherapy on the response of non-small cell lung cancer (NSCLC) tumour models and a murine model of radiation induced fibrosis. MATERIALS AND METHODS: AZD6738 was evaluated as a monotherapy and in combination with radiation in vitro and in vivo using A549 and H460 NSCLC models. Radiation induced pulmonary fibrosis was evaluated by cone beam computed tomography (CBCT) and histological staining. RESULTS: AZD6738 specifically inhibits ATR kinase and enhanced radiobiological response in NSCLC models but not in human bronchial epithelial cells (HBECs) in vitro. Significant tumour growth delay was observed in cell line derived xenografts (CDXs) of H460 cells (p<0.05) which were less significant in A549 cells. Combination of AZD6738 with radiotherapy showed no significant change in lung tissue density by CBCT (p>0.5) and histological scoring of radiation induced fibrosis (p>0.5). CONCLUSION: Inhibition of ATR with AZD6738 in combination with radiotherapy increases tumour growth delay without observable augmentation of late radiation induced toxicity further underpinning translation towards clinical evaluation in NSCLC.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Pirimidinas/farmacologia , Sulfóxidos/farmacologia , Índice Terapêutico , Animais , Proteínas Mutadas de Ataxia Telangiectasia/antagonistas & inibidores , Linhagem Celular Tumoral , Tomografia Computadorizada de Feixe Cônico , Feminino , Humanos , Indóis , Camundongos , Camundongos Endogâmicos C57BL , Morfolinas , Sulfonamidas , Ensaios Antitumorais Modelo de Xenoenxerto
13.
Nanomedicine (Lond) ; 11(16): 2035-47, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27463088

RESUMO

AIM: Gold nanoparticles have attracted significant interest in cancer diagnosis and treatment. Herein, we evaluated the theranostic potential of dithiolated diethylenetriamine pentaacetic acid (DTDTPA) conjugated AuNPs (Au@DTDTPA) for CT-contrast enhancement and radiosensitization in prostate cancer. MATERIALS & METHODS: In vitro assays determined Au@DTDTPA uptake, cytotoxicity, radiosensitizing potential and DNA damage profiles. Human PC3 xenograft tumor models were used to determine CT enhancement and radiation modulating effects in vivo. RESULTS: Cells exposed to nanoparticles and radiation observed significant additional reduction in survival compared with radiation only. Au@DTDTPA produced a CT enhancement of 10% and a significant extension in tumor growth delay from 16.9 days to 38.3 compared with radiation only. CONCLUSION: This study demonstrates the potential of Au@DTDTPA to enhance CT-image contrast and simultaneously increases the radiosensitivity of prostate tumors.


Assuntos
Ouro/uso terapêutico , Nanopartículas Metálicas/uso terapêutico , Ácido Pentético/uso terapêutico , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radiossensibilizantes/uso terapêutico , Animais , Linhagem Celular Tumoral , Tomografia Computadorizada de Feixe Cônico , Ouro/química , Ouro/farmacocinética , Humanos , Masculino , Nanopartículas Metálicas/química , Nanopartículas Metálicas/ultraestrutura , Camundongos SCID , Ácido Pentético/análogos & derivados , Ácido Pentético/farmacocinética , Imagens de Fantasmas , Próstata/patologia , Próstata/efeitos da radiação , Neoplasias da Próstata/patologia , Radiossensibilizantes/química , Radiossensibilizantes/farmacocinética , Compostos de Sulfidrila/química , Compostos de Sulfidrila/farmacocinética , Compostos de Sulfidrila/uso terapêutico , Nanomedicina Teranóstica
14.
Phys Med ; 31(5): 529-35, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25964129

RESUMO

PURPOSE: To develop and test the suitability and performance of a comprehensive quality assurance (QA) phantom for the Small Animal Radiation Research Platform (SARRP). METHODS AND MATERIALS: A QA phantom was developed for carrying out daily, monthly and annual QA tasks including: imaging, dosimetry and treatment planning system (TPS) performance evaluation of the SARRP. The QA phantom consists of 15 (60 × 60 × 5 mm(3)) kV-energy tissue equivalent solid water slabs. The phantom can incorporate optically stimulated luminescence dosimeters (OSLD), Mosfet or film. One slab, with inserts and another slab with hole patterns are particularly designed for image QA. RESULTS: Output constancy measurement results showed daily variations within 3%. Using the Mosfet in phantom as target, results showed that the difference between TPS calculations and measurements was within 5%. Annual QA results for the Percentage depth dose (PDD) curves, lateral beam profiles, beam flatness and beam profile symmetry were found consistent with results obtained at commissioning. PDD curves obtained using film and OSLDs showed good agreement. Image QA was performed monthly, with image-quality parameters assessed in terms of CBCT image geometric accuracy, CT number accuracy, image spatial resolution, noise and image uniformity. CONCLUSIONS: The results show that the developed QA phantom can be employed as a tool for comprehensive performance evaluation of the SARRP. The study provides a useful reference for development of a comprehensive quality assurance program for the SARRP and other similar small animal irradiators, with proposed tolerances and frequency of required tests.


Assuntos
Tomografia Computadorizada de Feixe Cônico/instrumentação , Imagens de Fantasmas , Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/instrumentação , Animais , Controle de Qualidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA