Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(7): 1429-1439, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38757241

RESUMO

INTRODUCTION: Cryoballoon ablation is a safe and efficient rhythm control strategy in atrial fibrillation (AF) patients. The impact of time from diagnosis to ablation is unclear. The aim of this study was to examine the impact of timing of first-time cryoballoon ablation on AF recurrence in a nationwide cohort of AF patients. METHODS AND RESULTS: From nationwide registers, all AF patients ≥18 years of age who underwent first-time AF cryoballoon ablation in Denmark from 2012 to 2018 were included. The AF patients were stratified by ablation timing: Early group (≤1 year after AF diagnosis), intermediate group (1-3 years after AF diagnosis), and late group (≥3 years after AF diagnosis). By adjusted Cox regression models, the effect of timing on AF recurrence was examined. This study included 1064 AF patients with a median age of 63 years. Most patients were male (66%) and had paroxysmal AF (67%). The 1-year risk of AF recurrence increased from 31% in the early group to 41% and 44% in the intermediate and late group. The hazard ratios (95% confidence intervals) were 1.28 (0.95, 1.74) in the intermediate group and 1.42 (1.09, 1.86) in the late group when compared to the early group. Continuous diagnosis-to-ablation time seemed to have the greatest impact on AF recurrence within the first 2 years. CONCLUSION: In AF patients undergoing cryoballoon ablation, late timing of ablation was associated with a significantly higher AF recurrence rate when compared to early timing of ablation. These findings support early cryoballoon ablation to improve the outcomes after ablation.


Assuntos
Fibrilação Atrial , Criocirurgia , Frequência Cardíaca , Recidiva , Sistema de Registros , Tempo para o Tratamento , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Masculino , Criocirurgia/efeitos adversos , Feminino , Dinamarca/epidemiologia , Pessoa de Meia-Idade , Idoso , Fatores de Risco , Fatores de Tempo , Medição de Risco , Resultado do Tratamento , Potenciais de Ação , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia
2.
J Cardiovasc Electrophysiol ; 32(5): 1251-1258, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33713521

RESUMO

INTRODUCTION: Non-pulmonary vein (PV) triggers are a major cause of atrial tachyarrhythmia (ATA) recurrence after catheter ablation. However, the effect of the diagnosis-to-ablation time (DAT) on non-PV triggers in persistent atrial fibrillation is unknown. METHODS AND RESULTS: This observational study evaluated 502 consecutive persistent AF patients who underwent initial ablation. We compared 408 patients whose DAT was <3 years with 94 patients whose DAT was ≥3 years. Following PV and posterior wall isolation, 193 non-PV triggers, including 50 AFs, 30 atrial tachycardias (ATs), and 113 repetitive atrial premature beats, were elicited and ablated in 137 (27%) patients. Specifically, 80 non-PV AF/AT triggers were provoked in 64 (13%) patients, being identified more frequently in the DAT ≥ 3 years group than in the DAT < 3 years group (20% vs. 11%, p = .025) especially with a higher prevalence of coronary sinus/inferior left atrial triggers. During a median follow-up of 770 days, the ATA recurrence-free rate was higher in the DAT < 3 years group than the DAT ≥ 3 years group (79% vs. 53% at 2 years, p < .001). In a multivariate analysis, female sex (odds ratio: 2.70, p = .002) and a longer DAT (odds ratio: 1.13/year, p = .008) were predictors of non-PV AF/AT triggers, and a longer DAT (hazard ratio: 1.12/year, p < .001) and non-PV AT/AF triggers (hazard ratio: 1.79, p = .009) were associated with ATA recurrence. CONCLUSION: Early ablation after the first diagnosis of persistent AF may reduce emerging non-PV AF/AT triggers and ATA recurrence.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
3.
Europace ; 23(6): 861-867, 2021 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-33367708

RESUMO

AIMS: Catheter ablation of paroxysmal atrial fibrillation (AF) reduces AF recurrence, AF burden, and improves quality of life. Data on clinical and procedural predictors of arrhythmia recurrence are scarce and are flawed by the high rate of pulmonary vein reconnection evidenced during repeat procedures after pulmonary vein isolation (PVI). In this study, we identified clinical and procedural predictors for AF recurrence 1 year after CLOSE-guided PVI, as this strategy has been associated with an increased PVI durability. METHODS AND RESULTS: Patients with paroxysmal AF, who received CLOSE-guided PVI and who participated in a prospective trial in our centre, were included in this study. Uni- and multivariate models were plotted to find clinical and procedural predictors for AF recurrence within 1 year. Three hundred twenty-five patients with a mean age of 63 years (CHA2DS2VASc 1 [1-3], left atrium diameter 41 ± 6 mm) were included. About 60.9% were male individuals. After 1 year, AF recurrence occurred in 10.5% of patients. In a binary logistic regression analysis, the diagnosis-to-ablation time (DAT) was found to be the strongest predictor of AF recurrence (P = 0.011). Diagnosis-to-ablation time ≥1 year was associated with a nearly two-fold increased risk for developing AF recurrence. CONCLUSION: The DAT is the most important predictor of arrhythmia recurrence in low-risk patients treated with durable pulmonary vein isolation for paroxysmal AF. Whether reducing the DAT could improve long-term outcomes should be investigated in another trial.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/cirurgia , Qualidade de Vida , Recidiva , Resultado do Tratamento
4.
Int J Hyperthermia ; 38(1): 1263-1270, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34404325

RESUMO

PURPOSE: To investigate the effects of ablation time and distance between the radiofrequency ablation (RFA) electrode tip and a large vessel on the ablation zone in beagle livers. METHODS: Sixty-one percutaneous RFA coagulation zones were created near large vessels in 10 beagle livers in vivo. The ablated lesions were divided into four groups based on ablation time and distance between the electrode tip and a large vessel (group A, 3 min 0.5 cm; group B, 3 min 0 cm; group C, 5 min 0.5 cm; group D, 5 min 0 cm). The ablated area, long-axis diameters, short-axis diameters, and vessel wall injury were examined. RESULTS: With a fixed ablation time, the ablation zone created with the electrode tip at 0.5 cm from the large vessel was significantly larger than at 0 cm (p < .05). At a fixed distance between the electrode tip and vessel, the ablation zone created for 5 min was significantly larger than for 3 min (p < .05). The frequency of vessel wall injury in the 0 cm groups was significantly higher than that in the 0.5 cm groups (37.5% vs. 6.9%; p = .003, odds ratio, 7.43). The ratio of width to depth (Dw/Dz) was larger in the 0.5 cm groups than in the 0 cm groups (p < .001). CONCLUSION: The ablation zone increased with longer ablation times and greater distances between the RFA tip and large vessels for perivascular lesions. The distance between the needle tip and blood vessels is an important factor that affects the overall ablation outcome.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Animais , Cães , Eletrodos , Fígado/cirurgia , Agulhas
5.
Clin Cardiol ; 47(2): e24194, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38054342

RESUMO

BACKGROUND: Evidence was lacking for the early choice of radiofrequency ablation (RFA) among patients with early-onset atrial fibrillation (AF). HYPOTHESIS: This study aimed to explore whether earlier RFA was associated with better clinical outcomes among early-onset AF patients. METHODS: Patients, who were diagnosed with AF before 45 years and underwent their first RFA procedures at baseline of the China Atrial Fibrillation registry, were enrolled and divided into four diagnosis-to-ablation time (DAT) groups: DAT ≤ 1 year, 1 year < DAT ≤ 3 years, 3 years < DAT ≤ 6 years, and DAT > 6 years. Another group of nonablation patients, who were newly diagnosed with AF and younger than 45 years, were also included. Adjusted associations of groups with composite cardiovascular events (cardiovascular death, embolism, major hemorrhages, or cardiac rehospitalization) or recurrent AF were analyzed using Cox proportional hazards models. RESULTS: Among 1694 patients who underwent their first RFA at enrollment, incidences of composite cardiovascular outcomes were increasing with extension of DAT (DAT ≤ 1 year: 6.1/100 person-years, 1 year < DAT ≤ 3 years: 7.9/100 person-years, 3 years < DAT ≤ 6 years: 7.6/100 person-years, DAT > 6 years: 10.5/100 person-years; p < .001). In comparison with DAT > 6 years group, the DAT ≤ 1 year group was associated with reduced risk of cardiovascular events (adjusted hazard ratio, HR [95% confidence interval, CI] = 0.64 [0.47-0.87], p = .005) and AF recurrence (adjusted HR [95% CI] = 0.70 [0.57-0.88], p = .002). Associations remained similar after stratified by AF types. Compared to nonablation group (n = 413), DAT ≤ 1year patients tended to show lower cardiovascular risk (adjusted HR [95% CI] = 0.78 [0.58-1.05], p = .099) and lower risk of recurrent AF (adjusted HR [95% CI] = 0.46 [0.38-0.55], p < .001). CONCLUSIONS: A shorter DAT was associated with a lower risk of cardiovascular events and recurrent AF for early-onset AF patients.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Fatores de Risco , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Frequência Cardíaca , Recidiva
6.
Diseases ; 12(2)2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38391785

RESUMO

BACKGROUND: Catheter ablation (CA) for atrial fibrillation (AF) is superior to antiarrhythmic drugs in maintaining sinus rhythm. Novel evidence suggests that increasing the time between the first diagnosis of AF and ablation, or diagnosis-to-ablation time (DAT), is a predictor for AF recurrence post-ablation. PURPOSE: Our primary objective was to investigate the relationship between DAT and AF recurrence after a first ablation. METHODS: Patients with AF who underwent CA in our center were enrolled consecutively, and a retrospective analysis was performed. DAT was treated as a continuous variable and reported as a median for the group with recurrence and the group without recurrence. DAT was also considered as a categorical variable and patients were stratified into three categories: DAT < 1 year, DAT < 2 years, and DAT < 4 years. RESULTS: The cohort included 107 patients, with a mean age of 54.3 ± 11.7 years. Mean DAT was significantly longer in those with AF recurrence: 4.9(3.06) years versus 3.99(3.5) (p = 0.04). The Kaplan-Meier curve revealed a higher likelihood of AF-free status over time for patients with DAT < 2 years compared to those with DAT > 2 years (p = 0.04). Cox multivariate analysis indicated that left atrial volume index (LAVI), obstructive sleep apnoea (OSA), and DAT > 2 years were independently associated with AF recurrence after a single AF ablation procedure (p = 0.007, p = 0.02, and p = 0.03, respectively). CONCLUSION: A shorter duration between the first AF diagnosis and AF ablation is associated with an increased likelihood of procedural success after a single AF ablation procedure.

7.
J Am Heart Assoc ; 13(7): e032722, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38533962

RESUMO

BACKGROUND: Guidelines recommend prioritizing treatment with antiarrhythmic drugs before referral of patients with atrial fibrillation to ablation, delaying a potential subsequent ablation. However, delaying ablation may affect ablation outcomes. We sought to investigate the impact of duration from diagnosis to ablation on the risk of atrial fibrillation recurrence and adverse events. METHODS AND RESULTS: Using Danish nationwide registries, all patients with first-time ablation for atrial fibrillation were identified and included from 2010 to 2018. Patients were divided into 4 groups by diagnosis-to-ablation time: <1.0 year (early ablation), 1.0 to 1.9 years, 2.0 to 2.9 years, and >2.9 years (late ablation). The primary end point was atrial fibrillation recurrence after the 90-day blanking period, defined by admission for atrial fibrillation, cardioversions, use of antiarrhythmic drugs, or repeat atrial fibrillation ablations. The secondary end point was a composite end point of heart failure, ischemic stroke, or death, and each event individually. The study cohort consisted of 7705 patients. The 5-year cumulative incidence of atrial fibrillation recurrence in the 4 groups was 42.9%, 54.8%, 55.9%, and 58.4%, respectively. Hazard ratios were 1.20 (95% CI, 1.07-1.35), 1.29 (95% CI, 1.13-1.47), and 1.40 (95% CI, 1.28-1.53), respectively, with the early ablation group as reference. The hazard ratio for the combined secondary end point was 1.22 (95% CI, 1.04-1.44) in the late ablation group compared with the early ablation group. CONCLUSIONS: In patients undergoing ablation for atrial fibrillation, early ablation was associated with a significantly lower risk of atrial fibrillation recurrence. Furthermore, the associated risk of heart failure, ischemic stroke, or death was significantly lower in early-compared with late-ablation patients.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , AVC Isquêmico , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Antiarrítmicos/uso terapêutico , Insuficiência Cardíaca/tratamento farmacológico , AVC Isquêmico/etiologia , Dinamarca/epidemiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva , Resultado do Tratamento
8.
JACC Clin Electrophysiol ; 9(11): 2263-2272, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37656100

RESUMO

BACKGROUND: Diagnosis-to-ablation time (DAT) strongly predicts recurrence of atrial fibrillation (AF) after ablation. Whether this association holds with any lower and/or upper limits is unknown. OBJECTIVES: The goal of this study was to assess the impact of DAT on AF recurrence in search of lower and upper DAT thresholds. METHODS: A total of 2,000 patients with AF from 2 cohorts of 1,000 patients each (69% male; age 62 ± 10 years) undergoing pulmonary vein isolation (PVI) between 2005-2014 and 2017-2019 were followed up for 3 years. RESULTS: Clinical success was achieved in 61.7% of patients. Median DAT decreased over time from 36 months (Q1-Q3: 12-72 months) in the first cohort to 12 months (Q1-Q3: 5-48 months) in the second cohort (P < 0.001). A multivariable Cox proportional hazards fitted model of AF recurrence rate in relation to DAT (range: 0-288 months) showed a steep rise in AF recurrence, from 27% to 40% in the first 36 months (d%/dt = 0.36), with a first inflection point at 36 months, and a less steep rise to 45% until 90 months (d%/dt = 0.09), with flattening beyond 90 months (d%/dt = 0.026). Rise in AF recurrence rate in the first 36 months was higher in patients with persistent AF (from 40% to 54%; d%/dt = 0.39) than in patients with paroxysmal AF (19% to 29%; d%/dt = 0.28). CONCLUSIONS: The association between DAT and AF recurrence has no lower limit ("the shorter the better"), whereas little gain is to be expected beyond 36 months ("the longer the more irrelevant"). Our data advocate for performing PVI as early as possible, certainly within 3 years of AF diagnosis, and even more so in persistent AF.


Assuntos
Fibrilação Atrial , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Fatores de Tempo
9.
Heart Rhythm O2 ; 3(6Part A): 639-646, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36589916

RESUMO

Background: Outcomes following catheter ablation (CA) for atrial fibrillation (AF) improve as the diagnosis-to-ablation time (DAT) shortens. Use of a protocol-based integrated care model through a dedicated atrial fibrillation clinic (AFC) may serve to standardize treatment pathways and decrease DAT. Objective: To evaluate the DAT and clinical characteristics of patients with AF referred from an AFC vs a conventional electrophysiology clinic (EC). Methods: Retrospective analysis was completed in consecutive patients undergoing index AF ablation at Riverside Methodist Hospital in 2019 with minimum 1 year follow-up. Patients were categorized based off their CA referral source (AFC vs EC) and where the initial visit following index diagnosis of AF occurred (AFC vs EC). Results: A total of 182 patients (mean age 65 years, 64% male) were reviewed. Patients referred from an AFC (21%) had a median DAT of 342 days (interquartile range [IQR], 125-855 days) compared to patients referred from EC (79%) with a median DAT of 813 days (IQR, 241-1444 days; P = .01). Patients with their index visit following AF diagnosis occurring in the AFC (9%) had significantly shorter median DAT (127 days [IQR, 95-188 days]) compared to EC (91%) (789 days [IQR, 253-1503 days]; P = .002). Patients with DAT <1 year had lower AF recurrence than patients with DAT >1 year (P = .04, hazard ratio = 0.58, 95% confidence interval 0.3418-1.000). Conclusion: DAT is a modifiable factor that may affect CA outcomes. Significant reductions in DAT were observed in patients evaluated through a dedicated AF clinic.

10.
Front Cardiovasc Med ; 8: 692945, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34557528

RESUMO

Background: Ablation of para-hisian accessory pathways (APs) remains challenging due to anatomic characteristics, and a few studies have focused on the causes for recurrence of radiofrequency ablation of para-hisian APs. Objective: This retrospective single center study aimed to explore the risk factors for recurrence of para-hisian APs. Methods: One hundred thirteen patients who had para-hisian AP with an acute success were enrolled in the study. In the 6-year follow-up, 15 cases had a recurrent para-hisian AP. Therefore, 98 patients were classified into the success group, while 15 patients were classified into the recurrence group. Demographic and ablation characteristics were analyzed. Results: Gender difference was similar in two groups. The median age was 36.2 years old and was younger in the recurrence group. Maximum ablation power was significantly higher in the success group (29 ± 7.5 vs. 22.9 ± 7.8, p < 0.01). Ablation time of final target sites was found to be markedly higher in the success group (123.4 ± 53.1 vs. 86.7 ± 58.3, p < 0.05). Ablation time <60 s was detected in 12 (12.2%) cases in the success group and 7 (46.7%) cases in the recurrence group (p < 0.01). Occurrence of junctional rhythm was significantly higher in the recurrence group (25.5% vs. 53.3%, p < 0.05). No severe conduction block, no pacemaker implantation, and no stroke were reported. Junctional rhythm during ablation (OR = 3.833, 95% CI 1.083-13.572, p = 0.037) and ablation time <60 s (OR = 5.487, 95% CI 1.411-21.340, p = 0.014) were independent risk factors for the recurrence of para-hisian AP. Conclusions: With careful and accurate mapping, it is relatively safe to ablate para-hisian AP. If possible, proper extension of ablation time could reduce the recurrence rate of para-hisian APs.

11.
Comput Biol Med ; 127: 104101, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33161335

RESUMO

Thermal ablation is currently used to treat tumors, whether benign or malignant. The most common types of thermal ablation procedures are the radiofrequency ablation (RFA) and the microwave ablation (MWA). Both generate heat in the tissues leading to an elevation in the tissue temperature level from 50-60∘C causing tissues death. In this work, the finite-element method (FEM) is used to model the human liver with a Hepatocellular Carcinoma to obtain the relationship between the power used in microwave radiation, exposure time, and resultant temperature at three microwave frequencies: 433, 915 MHz, and 2.45 GHz. Different hepatic tumor diameters from 20 to 50 mm and the best position to place the probe in the tumor are studied for complete tumor ablation using the lowest required power. A comparison is carried out for four different slotted probes: single slot (SS), multi slot (MS), single slot with 1T ring (SS1T), and single slot with shifted 1T ring (SSST) using the same conditions. The results indicate that the thermal distribution varies according to the type of the used probe. In addition, a relation is deduced between the power and time to assist the physician while using those probes to ablate different tumor sizes. The results reported a reflection coefficient -19.072 dB using the SSS1T probe, while the SS1T provided -4.5582 dB. It is found that a tumor with a diameter of 24, 28, 36, and 39 mm can be completely ablated using power 20 W for a period of 3, 5, 10 and 15 min, respectively, using the SSS1T probe. However, using the same conditions with the SS1T probe, a tumor with diameter 19, 24, 30, and 33 can be ablated, respectively.


Assuntos
Técnicas de Ablação , Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Ablação por Radiofrequência , Carcinoma Hepatocelular/diagnóstico por imagem , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Micro-Ondas
12.
J Arrhythm ; 36(2): 289-294, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32256876

RESUMO

BACKGROUND: Diagnosis-to-ablation time (DTAT) has been postulated to be one of the predictors of atrial fibrillation (AF) recurrence, and it is a "modifiable" risk factor unlike that of many electrocardiographic or echocardiographic parameters. This development may change our consideration for ablation. In this systematic review and meta-analysis, we aim to analyze the latest evidence on the importance of DTAT and whether they predict the AF recurrence after catheter ablation. METHODS: We performed a comprehensive search on topics that assess diagnosis-to-ablation time (DTAT) and AF recurrence from inception up until August 2019 through PubMed, EuropePMC, Cochrane Central Database, and http://ClinicalTrials.gov. RESULTS: There was a total of 3548 patients from six studies. Longer DTAT was associated with increased risk for AF recurrence in all studies included. Meta-analysis of these studies showed that DTAT had a hazard ratio (HR) of 1.19 [1.02, 1.39], P = .03; I 2: 92% for AF recurrence. Upon sensitivity analysis by removing a study, HR became 1.24 [1.16, 1.32], P < .001; I 2: 29%. Meta-analysis on DTAT time >3 years had HR 1.73 [1.54, 1.93], P < .001; I 2: 45% for the recurrence of AF. Upon subgroup analysis of data that compared >6 years to <1 year, the HR was 1.93 [1.62, 2.29], P < .001; I 2: 0%. CONCLUSION: Longer DTAT time is associated with an increased risk of AF recurrence. Hence, determining management at the earliest possible moment to avoid delay is of utmost importance.

13.
Int J Cardiol ; 291: 69-76, 2019 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-30948218

RESUMO

BACKGROUND: The impact of delays in the treatment with radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF) has not been well evaluated. The aim of this study was to investigate the impact of diagnosis-to-ablation time (DAT) on the long-term clinical outcomes after AF-RFCA. METHODS: We enrolled 1206 consecutive patients undergoing first-time RFCA for AF. The study population was divided into 2 groups based on DAT: short (<3 years) (N = 675) and long (>3 years) (N = 531) DAT groups. RESULTS: Mean follow-up duration was 5.0 ±â€¯2.5 years. The 5-year event-free rates from recurrent atrial tachyarrhythmias after the first and second RFCAs were significantly higher in short DAT group than in long DAT group (60.2% versus 48.3%, log-rank P < 0.001; 83.2% versus 75.2%, log-rank P = 0.02, respectively), leading to reduced cardiovascular hospitalization in short DAT group. After adjusting baseline differences, short DAT was independently associated with lower arrhythmia recurrence rates after the first and second RFCAs (hazard ratio [HR] 0.72, 95% confidence interval [CI] 0.60-0.86 and HR 0.72, 95%CI 0.55-0.95, respectively). There were no significant differences between the 2 groups in the event-free rates from all-cause and cardiovascular deaths, heart failure hospitalization, and ischemic stroke. However, among patients with a history of heart failure or reduced left ventricular function, the event-free rate from heart failure readmission was significantly higher in short DAT group (85.0% versus 61.0%, P = 0.004). CONCLUSIONS: In the management of AF, early RFCA was associated with significantly lower arrhythmia recurrence compared with delayed RFCA, leading to reduced cardiovascular hospitalization, especially in heart failure patients.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/tendências , Tomada de Decisão Clínica , Gerenciamento Clínico , Readmissão do Paciente/tendências , Tempo para o Tratamento/tendências , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/métodos , Tomada de Decisão Clínica/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
14.
Appl Spectrosc ; 73(1): 30-39, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29972315

RESUMO

The qualitative and quantitative analysis of doped nanomaterial containing iron (Fe) and tin (Sn) nanoparticles was investigated using laser-induced breakdown spectroscopy (LIBS). Doped nanoparticles were prepared via co-precipitation and hydrothermal processes. The emission spectra of ablated plasma of doped material revealed the existence of different species in the doped nanomaterial. Simple calibration-free LIBS (CF-LIBS) and internal reference self-absorption correction (IRSAC) CF-LIBS approaches were applied to emission spectra of nanomaterial for quantitative analysis. For both approaches, different spectroscopic parameters such as plasma temperature and electron number density were also determined. Plasma temperature was estimated using a Boltzmann plot and Saha-Boltzmann plot while electron number density was estimated by Stark broadening methods and Saha-Boltzmann equations. Results of both calibration-free approaches were compared with a weight percentage method and other recognized techniques such as laser ablation time of flight (LA-TOF) spectroscopy and energy dispersive X-ray (EDX). We concluded that our results provide good agreement with experimental data obtained using LA-TOF spectroscopy and a small deviation from data obtained using the EDX technique. The current work confirms LIBS as a valid analytical approach for quantitative analysis of nanomaterials.

17.
Int J Cardiol ; 171(1): 78-81, 2014 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-24315338

RESUMO

BACKGROUND: Restless patient is recalcitrant during ablation of atrial fibrillation (AF). We aimed to assess the association between patient movements during AF ablation and its outcome. METHODS: We examined the body movement during AF ablation in 78 patients with the use of a novel portable respiratory monitor, the SD-101, which also has the ability to quantify the frequency of body movements. RESULTS: The body movement index, defined as the number of the units of time with body movement events divided by the recording time (11.4 ± 6.5 events/h), was significantly correlated with the ablation time defined as the time from the first point of the ablation to the end of the procedure (1.2 ± 0.3h) (r=0.35; p=0.0014) and a total radiofrequency energy applied (56.6 ± 17.7 kW) (r=0.36; p=0.0015). A multiple linear regression analysis showed that non-paroxysmal AF (ß=0.25; p=0.036) and the body movement index (ß=0.36; p=0.0019) were independent determinants of the ablation time. The body movement index was similar in patients with and without recurrence of AF. CONCLUSIONS: Keeping patients motionless may be important to reduce the procedural duration of AF ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Monitorização Intraoperatória/métodos , Movimento/fisiologia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/instrumentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/instrumentação , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA