Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
BMC Oral Health ; 24(1): 415, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38575886

RESUMO

BACKGROUND: The objective of the present study was to evaluate the reliability of an augmented reality drilling approach and a freehand drilling technique for the autotransplantation of single-rooted teeth. MATERIALS AND METHODS: Forty samples were assigned to the following surgical techniques for drilling guidance of the artificial sockets: A. augmented reality technique (AR) (n = 20) and B. conventional free-hand technique (FT) (n = 20). Then, two models with 10 teeth each were submitted to a preoperative cone-beam computed tomography (CBCT) scan and a digital impression by a 3D intraoral scan. Afterwards, the autotrasplanted teeth were planned in a 3D dental implant planning software and transferred to the augmented reality device. Then, a postoperative CBCT scan was performed. Data sets from postoperative CBCT scans were aligned to the planning in the 3D implant planning software to analize the coronal, apical and angular deviations. Student's t-test and Mann-Whitney non-parametric statistical analysis were used to analyze the results. RESULTS: No statistically significant differences were shown at coronal (p = 0.123) and angular (p = 0.340) level; however, apical deviations between AR and FT study groups (p = 0.008) were statistically significant different. CONCLUSION: The augmented reality appliance provides higher accuracy in the positioning of single-root autotransplanted teeth compared to the conventional free-hand technique.


Assuntos
Realidade Aumentada , Implantes Dentários , Cirurgia Assistida por Computador , Humanos , Transplante Autólogo , Reprodutibilidade dos Testes , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico/métodos , Imageamento Tridimensional
2.
J Pers Med ; 14(1)2024 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-38248774

RESUMO

This study seeks to assess the accuracy of apical location using an augmented reality (AR) device with a free-hand method. Sixty (60) osteotomy site preparations were randomly assigned to one of two study groups: A. AR device (AR) (n = 30), and B. conventional free-hand method (FHM) (n = 30). Preoperative CBCT scans and intraoral scans were taken and uploaded to specialized implant-planning software to virtually plan preparations for the apical location osteotomy sites. The planning software was then used to automatically segment the teeth in each experimental model for their complete visualization using the AR device. A CBCT scan was carried out postoperatively after conducting the apical location procedures. The subsequent datasets were imported into therapeutic software to analyze the coronal, apical, and angular deviations. The Mann-Whitney non-parametric test was used. There were no statistically significant differences identified at the coronal (p = 0.1335), apical (p = 0.2401), and angular deviations (p = 0.4849) between the AR and FHM study groups. The augmented reality technique did not show a statistically significant accuracy of osteotomies for apical location when compared with the conventional free-hand method.

3.
Spec Care Dentist ; 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38693642

RESUMO

BACKGROUND: Diffuse idiopathic skeletal hyperostosis (DISH) is a potentially serious osteopathic disorder associated with coalescing ossifications of the anterior vertebrae and may be concomitant with a constellation of symptomatology and systemic comorbidities. There is limited dental literature describing this finding on panoramic radiographs and cone beam computed tomography (CBCT) scans. CASE PRESENTATIONS: Two case reports of DISH are provided. One patient manifested extensive ossifications along the cervical vertebrae and consequent episodes of dysphagia and hoarseness. The other affected patient's cervical ossification was found at an earlier stage of formation and without symptomatology. Panoramic radiography, cervical spine radiography, and CBCT examinations have been provided. CONCLUSION: Attending dental healthcare practitioners should carefully evaluate all areas of interest and surrounding fields of view when taking panoramic radiographs and CBCT scans for manifestations of DISH and other potential disorders of the cervical vertebrae. A suspected radiologic finding of DISH should prompt timely referral for comprehensive medical assessment to mitigate neurologic deficits and other comorbidities.

4.
Cranio ; : 1-4, 2023 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-36946617

RESUMO

BACKGROUND: The hypoglossal nerve stimulator (HNS) device has been employed in some patients with refractory or unsatisfactory outcomes to chronic obstructive sleep apnea management. The objective of this article is to increase recognition of the radiologic appearances of this device within the head and neck region, as seen on extraoral radiographic and cone beam computed tomography (CBCT) images. CLINICAL PRESENTATION: A 55-year-old man, refractory to a multitude of apneic medical therapies, underwent a series of preorthognathic radiologic studies. Notably, an implanted HNS lead and ribbon electrodes appeared as hyperdense structures on the panoramic radiograph, lateral cephalogram, and CBCT scan. CONCLUSION: This article provides various radiologic views of the primary components of an HNS. Clinicians should be able to recognize the presence of neurostimulator devices used for management of chronic sleep apnea within the radiologic field of view of examinations of the head and neck.

5.
J Clin Med ; 11(4)2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-35207285

RESUMO

The aim of this study was to analyse and compare the position of single-rooted autotransplanted teeth using computer-aided SNT drilling and conventional freehand (FT) drilling, by comparing the planned and performed position at the coronal, apical and angular level. MATERIALS AND METHODS: Forty single-root upper teeth were selected and distributed into the following study groups: A. Autotransplanted tooth using the computer-aided static navigation technique (SNT) (n = 20) and B. Autotransplanted tooth using the conventional free-hand technique (FT) (n = 20). Afterwards, the teeth were embedded into two experimental models and 10 single-root upper teeth were randomly autotransplanted in each experimental model. The experimental models were submitted to a preoperative cone-beam computed tomography (CBCT) scan and a digital impression by a 3D intraoral scan, in addition to a postoperative CBCT scan, after the autotransplantation. Datasets from postoperative CBCT scans of the two study groups were uploaded to the 3D implant planning software, aligned with the autotransplantation planning, and the coronal, apical and angular deviations were measured. The results were analysed using Student's t-test and Mann-Whitney non-parametric statistical analysis. RESULTS: Coronal (p = 0.079) and angular (p = 0.208) statistical comparisons did not present statistically significant differences; however, statistically significant differences between the apical deviation of the SNT and FT study groups (p = 0.038) were also observed. CONCLUSIONS: The computer-aided static navigation technique does not provide higher accuracy in the positioning of single-root autotransplanted teeth compared to the conventional free-hand technique.

6.
J Pers Med ; 11(10)2021 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-34683175

RESUMO

To compare and contrast the accuracy of piezoelectric ultrasonic insert (PUI) and trephine bur (TB) osteotomy site preparation techniques for apical location. (1) Material and methods: A total of 138 osteotomy site preparations were randomly distributed into one of two study groups. Group A: TB technique (n = 69) and B: PUI technique (n = 69). A preoperative cone-beam computed tomography scan and an intraoral scan were performed and uploaded to implant-planning software to plan the virtual osteotomy site preparations for apical location. Subsequently, the osteotomy site preparations were performed in the experimental models with both osteotomy site preparation techniques and a postoperative CBCT scan was performed and uploaded into the implant-planning software and matched with the virtually planned osteotomy site preparations to measure the deviation angle and horizontal deviation as captured at the coronal entry point and apical end-point between osteotomy site preparations using Student's t-test statistical analysis. (2) Results: The paired t-test found statistically significant differences at the coronal entry-point deviations (p = 0.0104) and apical end-point deviations (p = 0.0104) between the TB and PUI study groups; however, no statistically significant differences were found in the angular deviations (p = 0.309) between the trephine bur and piezoelectric ultrasonic insert study groups. (3) Conclusions: The results showed that the TB is more accurate than the PUI for apical location.

7.
J Pers Med ; 11(11)2021 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-34834446

RESUMO

In the present retrospective study, we aimed to assess the replicability and reproducibility of a novel digital measurement technique for analyzing the volumes of the left and right maxillary sinuses and the nasal and maxillary sinus airway complex after a sinus lift procedure using the lateral window approach, to provide an accurate measurement technique for easily applying in clinical practice and to allow pre-operative assessment of maxillary sinus lift surgery, avoiding complications and making surgery more predictable. MATERIAL AND METHODS: Thirty patients with partially edentulous posterior maxilla were selected and submitted to bilateral sinus lift using the lateral window approach technique, with grafting materials selected and submitted to cone beam computed tomography (CBCT) scans, both pre- and postoperatively. Then, datasets were uploaded to therapeutic digital planning software to measure the volume of the right and left maxillary sinuses and the nasal and maxillary sinus airway complex. Gage R&R statistical analysis was performed to assess the replicability and reproducibility of the digital measurement technique. RESULTS: The variability attributable to the novel digital measurement technique was 3.4% for replicability and 3.4% for reproducibility of the total variability of the samples. CONCLUSION: The novel digital method proposed is a replicable and reproducible technique for analyzing the volume of the right and left maxillary sinuses and the nasal and maxillary sinus airway complex after a sinus lift using the lateral window approach technique, allowing an accurate pre-operative assessment of maxillary sinus lift surgery, avoiding complications and making surgery more predictable.

8.
World Neurosurg ; 135: e405-e409, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31821910

RESUMO

BACKGROUND: Cone beam computed tomography (CBCT) imaging is used commonly in neurointerventional surgery for rapid intraprocedural assessment and planning of intracranial interventions. Our goal was to evaluate the ability of immediate postprocedural CBCT scan in assessing potential complications in pediatric patients. METHODS: A retrospective review was completed to include all pediatric patients at our hospital with an immediate postprocedural CBCT scan with the Artis Q system. Demographic, clinical, and imaging data were examined. CBCT images were reviewed by 3 independent neurointerventionalists to assess ventricular system/subarachnoid spaces, gray-white differentiation, and ischemia or hemorrhage if present. Each assessment was rated qualitatively on a 4-point scale and was compared with conventional computed tomography (cCT) scan when available. Interrater reliability was assessed and radiation dose data were reviewed. RESULTS: Thirty-five patients were included with an average age of 11.0 ± 5.1 years (median, 10.9; range, 1.1-18 years). Of the patients, 54.3% were boys; 34.3% were Hispanic and 34.3% were non-Hispanic white. Diagnoses included a variety of vascular pathologies. CBCT scan had a mean score of 2.69 ± 0.54 out of 3 for ventricular and subarachnoid space assessment with a combined interrater reliability of 0.82, 1.71 ± 1.38 for hemorrhage with a combined interrater reliability of 1.00, and 0.52 ± 0.60 for gray-white differentiation with a combined interrater reliability of 0.79. CONCLUSIONS: Immediate postprocedural CBCT images were adequate to detect ventricular size/subarachnoid spaces changes and large volume hemorrhage compared with cCT scan in pediatric patients. However, there are limitations using immediate CBCT images to detect small volume hemorrhage and ischemic changes.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Hemorragia Cerebral/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Procedimentos Neurocirúrgicos/efeitos adversos , Pré-Escolar , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Lactente , Masculino , Variações Dependentes do Observador , Complicações Pós-Operatórias/diagnóstico por imagem , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem
9.
World Neurosurg ; 131: 137-140, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31382069

RESUMO

BACKGROUND: The endoscopic endonasal approach for the craniovertebral junction (CVJ), instead of the microscopic transoral approach, has been widely adopted and accepted, especially in resection of the odontoid process for basilar invagination. However, there is concern regarding insufficient resection of odontoid and surgical complications, including vessel injuries, because this is a historically immature procedure. Here, we report a surgical case of endoscopic endonasal odontoidectomy (EEO) in the hybrid operating room (hOR) for improvement of its safety and reliability. CASE DESCRIPTION: A 70-year-old man presented with a 2-month history of myelopathic gait disturbance and swallowing disturbance. Neuroimaging analysis indicated medulla oblongata compression associated with basilar invagination. The patient underwent EEO in the hOR after posterior instrumented fixation. With the hOR, the extent of bone resection and anatomic orientation were confirmed intraoperatively. Postoperative course was uneventful, and symptoms were improved after surgery. CONCLUSIONS: The application of the hOR may make the EEO safe and precise for anterior decompression of the CVJ. To our knowledge, this is the first case report describing clinical experience of EEO in the hOR.


Assuntos
Cirurgia Endoscópica por Orifício Natural , Processo Odontoide/cirurgia , Cirurgia Assistida por Computador , Idoso , Encefalopatias/diagnóstico por imagem , Encefalopatias/etiologia , Encefalopatias/cirurgia , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Humanos , Masculino , Salas Cirúrgicas , Cirurgia Assistida por Computador/métodos
10.
J Conserv Dent ; 20(4): 273-277, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29259367

RESUMO

The purpose of these case reports is to emphasize the importance of knowledge regarding the root canal morphology and current diagnostic aids one should have as both of these important factors going to affect the prognosis of the endodontic treatment. These two case reports describe the maxillary and mandibular first molars with multiple canals. After clinical and radiographic diagnosis, additional help of cone-beam computed tomography (CBCT) of mandibular molar has been taken to evaluate the morphology and canal pattern; while maxillary molar was evaluated using CBCT scan to evaluate the canal configuration and obturation. In CBCT evaluation, the mandibular molar was diagnosed with six separated canals with three mesial and three distal canals and with radix paramolaris and radix entomolaris. The maxillary molar had five canals with three mesiobuccal (MB) canals. Both molars were instrumented with conventional hand and rotary file systems and obturated by conventional lateral compaction method. The axial images from CBCT show Vertucci Type VIII canal pattern in both roots of first mandibular molars and in MB root of maxillary first molar Sert and Bayirli Type XVIII canal configuration and no accessory canal in distobuccal and palatal root. With the recent innovations in diagnostic and operating aids, we can come across many variations in the root canal morphology of both mandibular and maxillary teeth, especially multi-rooted one (i.e., molars), and the knowledge of which leads to successful endodontic treatment with an excellent prognosis.

11.
Dent Res J (Isfahan) ; 14(6): 418-422, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29238381

RESUMO

BACKGROUND: The anterior loop is an important structure in the interforaminal area of the mandible. The aim of the present study was to assess the prevalence and length of the anterior loop of mental nerve using cone beam computed tomography (CBCT) scan and to compare the differences between age, gender, and side. MATERIALS AND METHODS: A total of 180 projections were analyzed in different sectional planes. The inferior alveolar nerve was determined. To measure the length of anterior loop in tangential plane, two parallel lines from the anterior point of mental foramen and anterior point of anterior loop were drawn. The distance between these two lines was measured by drawing a perpendicular line on them. The data were analyzed by SPSS (version 22). McNemar's test, Chi-square test, and t-test were performed to compare the significance of findings regarding side, age, and gender. P < 0.05 was considered statistically significant. RESULTS: The results showed that 32.8% of images had anterior loop. The mean lengths of anterior loop in the right and left sides were 2.69 mm (standard deviation [SD] = 1.56) and 2.36 mm (SD = 1.16), respectively. There were no statistically significant differences between the mean lengths of the anterior loop in both sides (P = 0.18). CONCLUSION: Great care is required when placing implants in proximity to mental foramen to avoid anterior loop injury. Because of the variations of anterior loop length in each patient, a fixed distance anterior to the mental foramen is not safe, and the anterior loop length should be determined for each individual. The use of CBCT provides accurate measurements of the length of anterior loop.

12.
Int J Oral Maxillofac Surg ; 45(10): 1309-14, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27269221

RESUMO

Orthognathic surgery has an influence on the overlying soft tissues of the translated bony maxillomandibular complex. Improvements in both function and facial appearance are the goals of surgery. However, unwanted changes to the soft tissues, especially in the nose region, frequently occur. The most common secondary change in the nasolabial region is widening of the alar base. Various surgical techniques have been developed to minimize this effect. The purpose of this study was to evaluate the changes in the nasal region due to orthognathic surgery, especially the alar width and nasal volume, using combined cone beam computed tomography (CBCT) and three-dimensional (3D) stereophotogrammetry datasets. Twenty-six patients who underwent a Le Fort I advancement osteotomy between 2006 and 2013 were included. From 2006 to 2010, no alar base cinch sutures were performed. From 2010 onwards, alar base cinch sutures were used. Preoperative and postoperative documentation consisted of 3D stereophotogrammetry and CBCT scans. 3D measurements were performed on the combined datasets, and the alar base width and nose volume were analyzed. No difference in alar base width or nose volume was observed between patients who had undergone an alar cinch and those who had not. Postoperatively the nose widened and the volume increased in both groups.


Assuntos
Maxila/patologia , Cartilagens Nasais , Deformidades Adquiridas Nasais/etiologia , Osteotomia de Le Fort/efeitos adversos , Complicações Pós-Operatórias , Técnicas de Sutura , Adolescente , Adulto , Cefalometria , Feminino , Humanos , Imageamento Tridimensional , Masculino , Maxila/cirurgia , Pessoa de Meia-Idade , Suturas
13.
J Int Oral Health ; 7(9): 127-33, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26435632

RESUMO

Open sinus lift surgery is a form of pre-prosthetic surgery for increasing the quality and quantity of bone in the posterior region of the maxilla. Pre-operative assessment of the maxillary sinus is essential for the success of this surgery. PubMed search was carried out in English language literature for open sinus lift surgery and cone-beam computed tomography (CBCT). The results focused on anatomic variants, vascular anatomy, complications, osteotomy/ostectomy window dimensions and thickness of the Schneiderian Membrane. 59 articles were included in this review. Features other than the height and the width of the residual alveolar ridge that should be evaluated in preoperative CBCT scan include the thickness of the lateral maxillary sinus wall, the presence of the alveolar antral artery and its diameter, the maxillary sinus floor width and angulation, irregularity of sinus floor, intimate relation of Schneiderian membrane with the roots of the adjacent teeth, sinus septum, and the quality of subantral bone. Other conditions that occasionally may be observed in special situations are also explained. More than ten parameters should be checked in evaluating CBCT images of paranasal sinuses other than the width and the length of the residual ridge in the posterior region of the maxilla. Each of them may have a significant impact on the results of the open sinus lift surgery.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA