1.
Clin Transplant ; 37(12): e15131, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37897211

RESUMO

INTRODUCTION: Monitoring for graft rejection is a fundamental tenet of post-transplant follow-up. In heart transplantation (HT) in particular, rejection has been traditionally assessed with endomyocardial biopsy (EMB). EMB has potential complications and noted limitations, including interobserver variability in interpretation. Additional tests, such as basic cardiac biomarkers, cardiac imaging, gene expression profiling (GEP) scores, donor-derived cell-free DNA (dd-cfDNA) and the novel molecular microscope diagnostic system (MMDx) have become critical tools in rejection surveillance beyond standard EMB. METHODS: This paper describes an illustrative case followed by a review of MMDx within the context of other noninvasive screening modalities for rejection. CONCLUSIONS: We suggest MMDx be used to assist with early detection of rejection in cases of discordance between EMB and other noninvasive studies.


Assuntos
Transplante de Coração , Miocárdio , Humanos , Miocárdio/patologia , Transplante de Coração/efeitos adversos , Biópsia , Perfilação da Expressão Gênica , Rejeição de Enxerto/diagnóstico , Rejeição de Enxerto/etiologia , Rejeição de Enxerto/epidemiologia