Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
BMC Oral Health ; 22(1): 356, 2022 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-35978297

RESUMO

BACKGROUND: The present study compared the effect of post space preparation time on the apical seal of two different sealers. METHODS: In the in vitro study, 94 central incisors were used. After the samples' root canal preparation, they were randomly assigned to four experimental groups (n = 21). The samples in groups 1 and 2 were obturated with AH Plus sealer, gutta-percha, and in groups 3 and 4 with Endoseal MTA bioceramic sealer and single cone technique. The post spaces in groups 1 and 3 were prepared immediately and in groups 2 and 4 with a delay. The samples were evaluated at 7-, 30-, and 90-day intervals for apical microleakage using the fluid filtration technique. The data were analyzed with SPSS 25, using three-way ANOVA and independent t-test. RESULTS: The apical microleakage in groups 3 and 4, obturated with Endoseal MTA bioceramic sealer and prepared immediately and after a delay, respectively, was not significantly different between the interval times. In group 2, obturated with AH Plus sealer and prepared for post space with a delay, the apical microleakage was significantly less than all the other groups. Group 1, obturated with AH Plus sealer and prepared for post space immediately, exhibited the least microleakage after seven days, but its microleakage increased over time to reach the level of groups 3 and 4. CONCLUSION: According to the results, the apical microleakage in the AH + sealer group and the delayed post-space preparation method, was significantly less than all the other groups over time.


Assuntos
Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular , Humanos , Resinas Epóxi/uso terapêutico , Guta-Percha , Materiais Restauradores do Canal Radicular/uso terapêutico , Obturação do Canal Radicular/métodos
2.
J Prosthodont ; 28(1): e222-e228, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28872730

RESUMO

PURPOSE: To evaluate microleakage in roots restored with fiber posts cemented using three different luting cements, to measure the volume of voids/gaps within the obturated/postcemented root canals, and to examine whether microleakage and the volume of voids/gaps were correlated. MATERIALS AND METHODS: Thirty-six extracted human mandibular incisors were decoronated, and the root canals were obturated using gutta-percha and sealer in the experimental groups (n = 30). Six roots were used as controls. A standard post space was prepared, and an identically sized fiber post was cemented in each experimental specimen using one of three luting cements (Panavia F2.0, Bifix SE, GC FujiCEM; n = 10 each). The specimens were scanned using micro-computed tomography, and the volume of voids/gaps was determined. The specimens were then subjected to a fluid filtration assay to evaluate microleakage. RESULTS: The volume of voids/gaps was significantly lower in the GC FujiCEM group, and significantly less microleakage occurred in the Bifix SE group compared with other groups (both p < 0.001). A significant correlation between the volume of voids/gaps and leakage was found only in the Panavia F2.0 group (p = 0.003; r = 0.830). No such correlation was found in the analysis of all groups combined. CONCLUSIONS: The group with the greatest volume of voids/gaps (Bifix SE) showed the least microleakage, and the group with the smallest volume of voids/gaps (GC FujiCEM) showed the most microleakage. Panavia F2.0 ranked between and exhibited significant correlation.


Assuntos
Cimentação/métodos , Cimentos Dentários/química , Infiltração Dentária , Técnica para Retentor Intrarradicular , Materiais Restauradores do Canal Radicular/química , Colagem Dentária , Infiltração Dentária/prevenção & controle , Materiais Dentários/química , Cavidade Pulpar/diagnóstico por imagem , Adesivos Dentinários/química , Vidro , Cimentos de Ionômeros de Vidro/química , Guta-Percha , Humanos , Hidroxibenzoatos , Incisivo , Teste de Materiais , Nitrofuranos , Cimentos de Resina , Obturação do Canal Radicular , Tratamento do Canal Radicular/métodos , Microtomografia por Raio-X
3.
Lasers Med Sci ; 33(9): 1883-1890, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29850962

RESUMO

The purpose of this in vitro study was to evaluate and compare the efficacy of erbium-doped yttrium aluminum garnet (Er:YAG) laser, neodymium-doped yttrium aluminum garnet (Nd:YAG) laser, PrevDent nano-hydroxyapatite toothpaste plus Repairing Serum Kit (PNH), and NUPRO Sensodyne Prophylaxis Paste with NovaMin (NPP) on dentin permeability reduction. Forty dentin discs obtained from bovine incisors were divided into four study groups: Er:YAG laser-treated (2940 nm; 0.2 W, 80 mJ/pulse, 3 Hz); Nd:YAG laser-treated (1064 nm; 1 W, 10 Hz); PNH-treated; and NPP-treated groups. The quantitative changes in permeability of each dentin disc were measured using a computerized fluid filtration method (CFFM) before and after desensitizer treatments. The data were analyzed using the Wilcoxon, paired-samples t, Kruskal-Wallis, and Mann-Whitney U tests. The dentin surfaces and tubules were also morphologically detected by scanning electron microscopy (SEM). In all groups, dentin permeability was significantly reduced after the desensitizer and laser treatments (p < 0.05). Among the groups, we detected a significant difference in only when comparing the Er:YAG laser- and NPP-treated groups (p = 0.034). SEM analysis revealed physical changes in the dentin surface in all groups. This in vitro study shows that all tested desensitizers and laser treatments reduced dentin permeability. Also, surface changes, such as complete or partial occlusion or shrinkage of dentin tubules, were observed in all groups. Although the laser groups performed best, the PNH protocol can be considered as an alternative therapeutic product. In addition, clinical and laboratory studies should be performed for this product, and their efficacy should be assessed by combined therapy with lasers.


Assuntos
Dessensibilizantes Dentinários/farmacologia , Permeabilidade da Dentina , Lasers de Estado Sólido , Animais , Bovinos , Dentina/efeitos dos fármacos , Dentina/ultraestrutura , Permeabilidade da Dentina/efeitos dos fármacos , Combinação de Medicamentos , Durapatita/farmacologia , Fluoretos/farmacologia , Vidro , Nanopartículas/química , Nitratos/farmacologia , Fosfatos/farmacologia
4.
Acta Odontol Scand ; 76(6): 415-421, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29334282

RESUMO

OBJECTIVE: The in vitro permeability characteristics of dentin have been studied extensively and used to evaluate the efficacy of various preventative and restorative procedures. The aim of this in vitro study was to precisely determine the dentin permeability of fluorotic premolar teeth using an electronic hydraulic conductance measurement system with photosensors and to compare the data with healthy premolars. METHODS: In total, 40 fluorotic and healthy premolar teeth with complete root formation that were extracted for orthodontic purposes and had no caries, restoration, fractures, or cracks were selected for this study. Teeth were classified according to a modified form of the dental fluorosis index of Thylstrup and Fejerskov. The dentin discs were placed in an electronic hydraulic conductance measurement system equipped with photosensors, which was designed for measurements of dentin permeability. The amount of distilled water passed through each dentin disc (µL/min) under a constant pressure was determined. Dentin permeability data of the fluorotic and healthy teeth were recorded and analyzed statistically. RESULTS: The present study showed that fluorosis influenced the volume of fluid that passed through the dentin and the dentin permeability was decreased, whereas dental fluorosis severity was increased in permanent teeth. CONCLUSION: The number of teeth with fluorosis is increasing, depending on fluorine sources, so more appropriate treatments will need to be evaluated by standardizing the methods employed in related studies.


Assuntos
Permeabilidade da Dentina/fisiologia , Dentina/fisiologia , Dentição Permanente , Fluorose Dentária/fisiopatologia , Dente Decíduo/fisiologia , Cárie Dentária , Humanos
5.
Clin Oral Investig ; 21(4): 1267-1276, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27299600

RESUMO

OBJECTIVES: The aim of the present study is to evaluate the possible correlation between sealer penetration into dentinal tubules and sealing ability both in presence and absence of smear layer. MATERIALS AND METHODS: Fourteen maxillary central incisors were treated with 5.25 % NaOCl +10 % EDTA to remove the smear layer (SL-free group) or 5.25 % NaOCl without EDTA (SL group). Root canals were filled using #25 Thermafil Obturators with Topseal sealer labelled with 0.1 wt% rhodamine B. Sealing ability was measured as fluid filtration rate with a fluid-flow meter using water supplemented with 0.3 % calcein fluorescent dye. Specimens were sectioned, observed under confocal microscope to co-localize the presence of sealer (rhodamine B labelling) into dentinal tubules and gaps (calcein labelling) into the root canal. The depth of sealer penetration into dentinal tubules and the percentage of sealer penetration around the root canal were measured at 3, 5 and 8 mm from the apex. RESULTS: No significant differences between groups were observed in fluid filtration rate nor in depth of calcein penetration. Sealer penetration depth and percentage into dentinal tubules were not significantly different between groups, except at 8-mm level in absence of smear layer. CONCLUSION: Sealer penetration at 3- and 5-mm levels was not influenced by smear layer while it was significantly reduced at 8-mm level. Fluid filtration rate was not correlated either with depth of calcein penetration nor with sealer penetration into dentinal tubules. CLINICAL RELEVANCE: The sealing ability of Topseal sealer is not affected by presence or absence of smear layer.


Assuntos
Dentina/efeitos dos fármacos , Resinas Epóxi/química , Materiais Restauradores do Canal Radicular/química , Preparo de Canal Radicular/métodos , Ácido Edético/química , Corantes Fluorescentes , Humanos , Técnicas In Vitro , Incisivo , Teste de Materiais , Microscopia Confocal , Rodaminas , Irrigantes do Canal Radicular/química , Camada de Esfregaço , Hipoclorito de Sódio/química , Propriedades de Superfície
6.
Eur J Oral Sci ; 124(3): 279-86, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27041355

RESUMO

The dynamic thermomechanical properties, sealing ability, and voids formation of an experimental obturation hydroxyapatite-reinforced polyethylene (HA/PE) composite/carrier system were investigated and compared with those of a commercial system [GuttaCore (GC)]. The HA/PE system was specifically designed using a melt-extrusion process. The viscoelastic properties of HA/PE were determined using a dynamic thermomechanical analyser. Human single-rooted teeth were endodontically instrumented and obturated using HA/PE or GC systems, and then sealing ability was assessed using a fluid filtration system. In addition, micro-computed tomography (µCT) was used to quantify apparent voids within the root-canal space. The data were statistically analysed using one-way anova and post hoc tests. The HA/PE composite exhibited important modulus and damping changes with an increase of temperature. The HA/PE system was more flexible than GC as the modulus of GC appeared to be significantly higher than that of HA/PE as a result of the high positive glass transition temperature (Tg ). However, HA/PE and GC presented similar sealing abilities. In conclusion, because sealing ability and voids formation were comparable between the tested materials, the experimental HA/PE system may be considered a suitable alternative material for root-canal obturation. Moreover, HA/PE possesses specific viscoelastic behaviour and lower melting points, which may facilitate root-canal retreatments.


Assuntos
Durapatita , Polietileno , Obturação do Canal Radicular , Microtomografia por Raio-X , Infiltração Dentária , Vidro , Humanos , Materiais Restauradores do Canal Radicular
7.
J Contemp Dent Pract ; 16(9): 733-9, 2015 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-26522599

RESUMO

AIM: The aim of this study was to compare the sealing ability of mineral trioxide aggregate (MTA), Portland cement (PC), Biodentine(TM) and Tech biosealer in repairing furcal perforations in primary molars using the fluid-filtration technique. MATERIALS AND METHODS: Fifty freshly extracted maxillary second primary molars were sectioned horizontally at the furcation region to create dentin disks of 1.5 mm (+ 0.1 mm) thickness. Five disks were not perforated and served as negative controls. In the remaining 45 disks, furcation perforations were prepared. Five disks did not receive furcation repair and served as positive controls. The remaining 40 disks were then randomly divided into four equal groups (10 disks in each group). Perforations were repaired with: MTA, PC, Biodentine(TM) or Tech Biosealer. The sealing ability of the tested materials was evaluated by measuring microleakage for each disk after four different storage periods: 24-hour, 1-month, 6-month and 1-year storage using fluid-filtration. Comparisons between the four materials and the four time periods were done using the two-way analysis of variance and the Scheffe multiple comparisons test. RESULTS: There was no significant difference between the mean microleakage values obtained in the four tested materials after 24 hours, 1, 6 month and 1 year. However, microleakage values for each individual material were significantly higher at 24 hours than at the other time intervals. CONCLUSION: Mineral trioxide aggregate, PC, Biodentine(TM) and Tech biosealer showed similar capabilities in sealing the furcal perforations of the primary molars, where the sealing ability improved over time for each individual material.


Assuntos
Compostos de Cálcio/uso terapêutico , Colagem Dentária , Cavidade Pulpar/lesões , Dente Molar/lesões , Materiais Restauradores do Canal Radicular/uso terapêutico , Dente Decíduo/lesões , Compostos de Alumínio/química , Compostos de Alumínio/uso terapêutico , Compostos de Cálcio/química , Infiltração Dentária/classificação , Dentina/lesões , Combinação de Medicamentos , Filtração/métodos , Humanos , Pressão Hidrostática , Técnicas In Vitro , Teste de Materiais , Óxidos/química , Óxidos/uso terapêutico , Distribuição Aleatória , Materiais Restauradores do Canal Radicular/química , Cimento de Silicato/química , Cimento de Silicato/uso terapêutico , Silicatos/química , Silicatos/uso terapêutico , Fatores de Tempo
8.
J Prosthodont ; 23(1): 45-9, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23724962

RESUMO

PURPOSE: Commercial fiber-reinforced dowel systems are marketed as having better adhesion and sealing ability than conventional metallic dowel systems. The aim of this in vitro study was to evaluate the microleakage of teeth restored with nine dowel systems. MATERIALS AND METHODS: Ninety mandibular second premolar teeth were decoronated, and nine homogenous groups were composed of ten teeth each. Root canal and dowel space preparations were made, and eight fiber-reinforced composite dowel systems and one stainless steel dowel system were used to fabricate dowel restorations. Microleakage measurements of the restored teeth were made with a modified fluid filtration method, and data were collected. One sample Kolmogorov-Smirnov, one-way ANOVA, and Tukey-HSD tests were performed on the relative microleakage data of the groups. RESULTS: Microleakage values were reported relative to those for teeth with unfilled canals. The highest and lowest relative microleakage values were recorded for the metallic Parapost (7.06 × 10(-4) %) and fiber-reinforced Everstick (3.55 × 10(-4) %) groups, respectively. Significant differences in relative microleakage between the fiber-reinforced dowels and stainless steel dowels were observed. Significant differences among the fiber-reinforced dowel groups were observed as well. CONCLUSIONS: The sealing ability of all fiber-reinforced composite dowels is not better than that of stainless steel dowels, and there are significant differences among different fiber-reinforced dowel systems as well. Differences among commercial dowel systems must be taken into consideration when making a selection.


Assuntos
Infiltração Dentária/classificação , Materiais Dentários/química , Técnica para Retentor Intrarradicular/instrumentação , Cimentação/métodos , Resinas Compostas/química , Ligas Dentárias/química , Colagem Dentária/métodos , Módulo de Elasticidade , Resinas Epóxi/química , Vidro/química , Humanos , Teste de Materiais , Polímeros/química , Quartzo/química , Cimentos de Resina/química , Preparo de Canal Radicular/métodos , Dióxido de Silício/química , Aço Inoxidável/química , Zircônio/química
9.
Iran Endod J ; 18(4): 206-210, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37829831

RESUMO

Introduction: Apical surgery aims to eradicate the apical part of the root and the lesion to enhance the healing. The sealing ability of retrograde filling material is an essential factor affecting the success rate of the surgery. Mineral trioxide aggregate (MTA) is the gold standard of retrograde filling materials, with approved sealing capability and biocompatibility. Newly introduced root repair material with an approved antibacterial effect similar to MTA is Nano-fast cement (NFC) which should be investigated for its sealing ability. This study aimed to evaluate the sealing ability of NFC vs. MTA. Materials and Methods: Root apices of 48 single-rooted teeth were resected at 90 degrees and were prepared at 3 mm depth. The teeth were randomly divided into 2 experimental groups (n=21), negative control group (n=3), and positive control group (n= 3). MTA and NFC plugs were condensed as retrograde filling material. The samples were evaluated by a modified fluid filtration device for 1 hour. The measurement was conducted at 24 h, 1, and 3 months. Data were analyzed by Friedman Test and Kruskal-Wallis test. Results: According to the results, NFC at 3-months interval showed the least microleakage, and MTA had the highest at the baseline. However, the results between the two groups were not statistically significant in all intervals. NFC reached the ideal sealing ability within 1 month, which was reached for MTA after 3 months. Conclusions: The results of this in vitro study showed that the microleakage value of NFC is comparable to MTA. In light of current findings, NFC shows characteristics of a suitable calcium silicate-based cement. Further clinical researches are needed to introduce the NFC as retrograde apical plug or for other endodontic applications.

10.
Environ Sci Pollut Res Int ; 30(19): 55034-55043, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36890402

RESUMO

The research objective of this investigation is to explore the influence of filtrate reducer and reservoir characteristics on the filtration reduction of drilling fluid during the drilling process, and the filtration reduction mechanism of drilling fluids is also revealed. The results obtained that a synthetic filtrate reducer can significantly reduce the filtration coefficient than that of the commercial filtrate reducer. Moreover, the filtration coefficient of drilling fluid constructed from synthetic filtrate reducer is reduced from 4.9 × 10-2 m3·min1/2 to 2.4 × 10-2 m3·min1/2 with an increase in the filtrate reducer content, which is much lower than that of the commercial filtrate reducer. The weaker filtration capacity of the drilling fluid containing the modified filtrate reducer is attributed to the combined action of the filtrate reducer containing multifunctional groups adsorbed on the sand surface and the hydration membrane adsorbed on the sand surface. Furthermore, the increase in reservoir temperature and shear rate increases the filtration coefficient of drilling fluid, indicating that low temperature and shear rate are conducive to improve the filtration capacity. Thus, the type and content of filtrate reducer are preferred during drilling in oilfield reservoir, but increasing reservoir temperature and shear rate are not recommended. It is necessary to confect the drilling mud with appropriate filtrate reducer such as the chemicals prepared herein during drilling operation.


Assuntos
Revelação , Areia , Filtração , Temperatura Baixa , Água
11.
Transl Stroke Res ; 13(5): 725-735, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35157256

RESUMO

Delayed cerebral ischemia (DCI) continues to be a sequela of aneurysmal subarachnoid hemorrhage (aSAH) that carries significant morbidity and mortality. Aside from nimodipine, no therapeutic agents are available to reduce the incidence of DCI. Pathophysiologic mechanisms contributing to DCI are poorly understood, but accumulating evidence over the years implicates several factors. Those have included microvessel vasoconstriction, microthrombosis, oxidative tissue damage, and cortical spreading depolarization as well as large vessel vasospasm. Common to these processes is red blood cell leakage into the cerebrospinal fluids (CSF) and subsequent lysis which releases hemoglobin, a central instigator in these events. This has led to the hypothesis that early blood removal may improve clinical outcome and reduce DCI. This paper will provide a narrative review of the evidence of hemoglobin as an instigator of DCI. It will also elaborate on available human data that discuss blood clearance and CSF drainage as a treatment of DCI. Finally, we will address a recent novel device that is currently being tested, the Neurapheresis CSF Management System™. This is an automated dual-lumen lumbar drainage system that has an option to filter CSF and return it to the patient.


Assuntos
Isquemia Encefálica , Hemorragia Subaracnóidea , Vasoespasmo Intracraniano , Isquemia Encefálica/tratamento farmacológico , Infarto Cerebral/complicações , Hemoglobinas , Humanos , Incidência , Hemorragia Subaracnóidea/complicações , Hemorragia Subaracnóidea/terapia , Vasoespasmo Intracraniano/complicações
12.
Artigo em Inglês | MEDLINE | ID: mdl-34712409

RESUMO

Background. The present study aimed to evaluate the sealing ability of three different calcium silicate-based materials in furcation perforations. Methods. Seventy-six human mandibular molar teeth were selected. Perforations were created in the center of the pulp chamber floor. The experimental teeth were randomly divided into three groups (n=22). Perforations were repaired with MTA Angelus, Endocem MTA, or EndoSequence BioCeramic Root Repair Material Fast Set Putty (BC-RRM Putty). Microleakage of the different repair materials to be tested was measured by computerized fluid filtration method at 24- and 72-hour intervals. Results. For each time interval, no statistically significant difference was observed between the groups. For Endocem MTA and BC-RRM Putty groups, the difference between the leakage values measured at both periods was not statistically significant (P > 0.05). However, there was a significant difference for the MTA Angelus group (P < 0.05). Conclusion. All the calcium silicate-based materials used in the present study showed similar performance in repairing furcation perforations at 24- and 72-hour intervals.

13.
Materials (Basel) ; 14(14)2021 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-34300934

RESUMO

It is well-known that the effect of interstitial fluid on the fracture pattern and strength of saturated high-strength concrete is determined by qualitatively different mechanisms at quasi-static and high strain rate loading. This paper shows that the intermediate range of strain rates (10-4 s-1 < ε˙ < 100 s-1) is also characterized by the presence of a peculiar mechanism of interstitial water effect on the concrete fracture and compressive strength. Using computer simulations, we have shown that such a mechanism is the competition of two oppositely directed processes: deformation of the pore space, which leads to an increase in pore pressure; and pore fluid flow. The balance of these processes can be effectively characterized by the Darcy number, which generalizes the notion of strain rate to fluid-saturated material. We have found that the dependence of the compressive strength of high-strength concrete on the Darcy number is a decreasing sigmoid function. The parameters of this function are determined by both low-scale (capillary) and large-scale (microscopic) pore subsystems in a concrete matrix. The capillary pore network determines the phenomenon of strain-rate sensitivity of fluid-saturated concrete and logistic form of the dependence of compressive strength on strain rate. Microporosity controls the actual boundary of the quasi-static loading regime for fluid-saturated samples and determines localized fracture patterns. The results of the study are relevant to the design of special-purpose concretes, as well as the assessment of the limits of safe impacts on concrete structural elements.

14.
J Oral Biol Craniofac Res ; 10(2): 220-226, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32489825

RESUMO

This systematic review aims to comparatively evaluate the sealing ability gutta-percha and resilon as root canal filling materials. A Medline search was conducted to identify in-vitro studies published between October 01, 2004 and October 01, 2019, conducted on human extracted teeth, published in English and testing the sealing ability of gutta-percha and resilon as root canal filling materials using fluid filtration method. The search identified fifty-five published articles. After a thorough screening, five articles meeting the selection, and validity assessment criteria were critically appraised. The results indicated that during the initial time-period, resilon/epiphany sealer has better sealing ability than gutta-percha. However, over a period of time the resilon system demonstrated increased fluid flow. Gutta-percha with AH plus sealer showed the best long term sealing ability.

15.
J Dent Sci ; 15(2): 186-192, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32595900

RESUMO

BACKGROUND/PURPOSE: A perfect sealing of root canal system is essential for preventing ingress of bacteria from the oral environment. The purpose of this study was to evaluate the apical sealing ability of bioceramic (EndoSequence BC Sealer®) and epoxy resin-based (AH Plus®) sealers at 24 h, 7 days and 4 weeks. MATERIALS AND METHODS: Forty two extracted human upper anterior teeth were sectioned to leave the root 15-mm long, then all the roots were instrumented using a set of ProTaper® rotary instruments. Four roots were selected randomly as controls, and the remaining 38 roots were randomly divided into 2 groups of 19 roots each: group 1: EndoSequence BC Sealer® and gutta-percha, and group 2: AH Plus® and gutta-percha using a multiple wave condensation technique. The apical sealing ability of the filled root canal was measured using the fluid filtration method with 200 mmHg (26.67 KPa) above atmospheric pressure at 24 h, 7 days and 4 weeks. Scanning electron microscopy (SEM) was used to assess the adaptation and penetration of the sealers. The apical microleakage between 2 groups was compared using Student's t-test. P < 0.05 was considered statistically significant. RESULTS: EndoSequence BC Sealer® had significantly better sealing ability than AH Plus® at all test periods (P < 0.001). SEM showed EndoSequence BC Sealer® had better penetration into dentinal tubules. CONCLUSION: Bioceramic sealer could promote proper sealing of root canals obturated with multiple wave condensation.

16.
Fluids Barriers CNS ; 17(1): 23, 2020 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-32178689

RESUMO

BACKGROUND: Blood removal from cerebrospinal fluid (CSF) in post-subarachnoid hemorrhage patients may reduce the risk of related secondary brain injury. We formulated a computational fluid dynamics (CFD) model to investigate the impact of a dual-lumen catheter-based CSF filtration system, called Neurapheresis™ therapy, on blood removal from CSF compared to lumbar drain. METHODS: A subject-specific multiphase CFD model of CSF system-wide solute transport was constructed based on MRI measurements. The Neurapheresis catheter geometry was added to the model within the spinal subarachnoid space (SAS). Neurapheresis flow aspiration and return rate was 2.0 and 1.8 mL/min, versus 0.2 mL/min drainage for lumbar drain. Blood was modeled as a bulk fluid phase within CSF with a 10% initial tracer concentration and identical viscosity and density as CSF. Subject-specific oscillatory CSF flow was applied at the model inlet. The dura and spinal cord geometry were considered to be stationary. Spatial-temporal tracer concentration was quantified based on time-average steady-streaming velocities throughout the domain under Neurapheresis therapy and lumbar drain. To help verify CFD results, an optically clear in vitro CSF model was constructed with fluorescein used as a blood surrogate. Quantitative comparison of numerical and in vitro results was performed by linear regression of spatial-temporal tracer concentration over 24-h. RESULTS: After 24-h, tracer concentration was reduced to 4.9% under Neurapheresis therapy compared to 6.5% under lumbar drain. Tracer clearance was most rapid between the catheter aspiration and return ports. Neurapheresis therapy was found to have a greater impact on steady-streaming compared to lumbar drain. Steady-streaming in the cranial SAS was ~ 50× smaller than in the spinal SAS for both cases. CFD results were strongly correlated with the in vitro spatial-temporal tracer concentration under Neurapheresis therapy (R2 = 0.89 with + 2.13% and - 1.93% tracer concentration confidence interval). CONCLUSION: A subject-specific CFD model of CSF system-wide solute transport was used to investigate the impact of Neurapheresis therapy on tracer removal from CSF compared to lumbar drain over a 24-h period. Neurapheresis therapy was found to substantially increase tracer clearance compared to lumbar drain. The multiphase CFD results were verified by in vitro fluorescein tracer experiments.


Assuntos
Remoção de Componentes Sanguíneos/métodos , Sangue , Catéteres , Líquido Cefalorraquidiano , Drenagem , Desenho de Equipamento , Modelos Biológicos , Punção Espinal , Hemorragia Subaracnóidea/terapia , Adulto , Remoção de Componentes Sanguíneos/instrumentação , Feminino , Humanos , Hidrodinâmica , Imageamento por Ressonância Magnética , Adulto Jovem
17.
Oper Neurosurg (Hagerstown) ; 16(5): E148-E153, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29873785

RESUMO

BACKGROUND AND IMPORTANCE: The amount of subarachnoid blood and the presence of toxic blood breakdown products in the cerebrospinal fluid (CSF) have long been associated with poor outcomes in aneurysmal subarachnoid hemorrhage. The Neurapheresis™ system (Minnetronix Inc, St. Paul, Minnesota) has been developed to filter CSF and remove blood products, and is being investigated for safety and feasibility in the ExtracorPoreal FILtration of subarachnoid hemorrhage via SpinaL CAtheteR (PILLAR) study. We report the first case using this novel device. CLINICAL PRESENTATION: A 65-yr-old female presented with a ruptured left posterior communicating artery aneurysm. Following placement of a ventriculostomy and coil embolization of her aneurysm, the patient underwent placement of a lumbar dual lumen catheter for CSF filtration as part of the PILLAR study. In this case, a total of 9 h of filtration during 31 h of catheter indwelling resulted in 309.47 mL of processed CSF without complication. Computed tomography images demonstrated an interval reduction of subarachnoid hemorrhage immediately after filtration. The patient was discharged home on postbleed day 11 and at 30 d showed good recovery. CONCLUSION: Safety of the Neurapheresis procedure was confirmed in this first case, and we will continue to evaluate safety of the Neurapheresis system through the PILLAR trial.


Assuntos
Aneurisma Roto/terapia , Remoção de Componentes Sanguíneos/métodos , Embolização Terapêutica/métodos , Aneurisma Intracraniano/terapia , Hemorragia Subaracnóidea/terapia , Ventriculostomia/métodos , Idoso , Aneurisma Roto/diagnóstico por imagem , Catéteres , Feminino , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Hemorragia Subaracnóidea/diagnóstico por imagem
18.
Saudi Dent J ; 31(1): 16-22, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30723363

RESUMO

AIM: This study evaluated the sealing ability of ProRoot MTA and Biodentine as root-end filling materials. METHOD: In total, twenty (N = 20) extracted human maxillary central incisor teeth were decontaminated, cleaned and decoronated. Instrumentation was performed according to the step back technique using #50 Flex-o-file. Then the canals were flared to #70 Flex-o-file. Obturation was performed with conventional gutta percha and a resinous sealer (AH26) using the lateral condensation technique. Resection of 3 mm of apical end of each root was achieved perpendicular to the long axis of the root. Root-end cavity was prepared in each sample ultrasonically then filled with tested materials (N = 10). Fluid filtration method was used to assess the sealing ability of each tested material at three different experimental periods; one day, one week and one month after setting. All data were tabulated and statistically analyzed with a level of significance set at P ≤ .05. RESULTS: At each specific time interval, the leakage mean values were not consistent among the tested materials. At one day interval, ProRoot MTA samples had a higher leakage mean value than Biodentine samples. However, this difference in leakage was not statistically significant (P > .05). At one week interval, both materials showed an increased degree of leakage mean value with no significant difference (P > .05). At one month interval, ProRoot MTA samples showed a decrease in leakage mean value, while the Biodentine samples showed a further increase in leakage mean value. This difference was statistically significant (P < .05). CONCLUSION: Although the sealing ability of ProRoot MTA is superior to Biodentine, Biodentine could be considered as an acceptable alternative to ProRoot MTA in peri-radicular surgeries.

19.
Eur Oral Res ; 52(3): 117-121, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30775713

RESUMO

PURPOSE: The aim of this study was to compare the short and long term apical sealing ability of different root canal sealers. MATERIALS AND METHODS: Fifty-five extracted human anterior single-root teeth were used. The coronal part of each tooth was removed and the root canals were prepared with NiTi rotary instruments. Teeth were divided into 5 study groups; Group I: MTA Fillapex (Angelus, Brazil); Group II: Sealapex (Sybron-Kerr, Romulus, MI, USA) and Group III: AH Plus (Dentsply, Konstanz, Germany) (n=15) and negative and positive control groups (n=5). The quality of root canal sealing was assessed by a fluid filtration method performed at 24 h and 180-day time intervals. Kruskal Wallis and Mann Whitney U tests were used to compare the groups. RESULTS: At 24 h evaluation, MTA Fillapex presented significantly less microleakage than the Sealapex and AH Plus (p<0.05). At long term interval (180-day), Sealapex and AH Plus presented significantly less microleakage than the MTA Fillapex (p<0.05). CONCLUSION: Sealapex and AH Plus showed significantly better sealing abilities than MTA Fillapex in the long term.

20.
J Int Soc Prev Community Dent ; 8(6): 503-507, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30596040

RESUMO

AIM AND OBJECTIVES: To evaluate the apical fill in relation to apical leakage using three different obturating techniques - Single Cone, Ultrafil 3D, and lateral condensation. MATERIALS AND METHODS: Sixty-six mandibular single-rooted premolar teeth were selected and were randomly assigned into three different groups of obturating techniques. The canals were prepared using 0.4/25 HyFlex CM (Coltene Endo) rotary system file and obturated with corresponding HyFlex CM Single Cone, Ultrafil 3D injectable technique, and lateral condensation. AH Plus (Dentsply, Detrey) has been used as the sealer. Twenty teeth each were assigned to the three experimental groups, and six teeth were used as positive and negative controls (3 in each group). Fluid filtration technique was used to determine the amount of apical leakage. The evaluation was done for 8 min at the interval of every 2 min. The same teeth were sectioned and a spectroscopic examination was done at 2 mm and 4 mm distance from the apices. The obtained data were statistically analyzed using analysis of variance test followed by post hoc turkeys test for multiple comparisons. RESULTS: The mean apical leakage was maximum for lateral condensation when compared to the Single Cone and Ultrafil 3D. The amount of apical fill at 2 mm and at 4 mm was found to be more in the Single Cone than the other two techniques. CONCLUSION: The present study concluded that Single Cone obturation technique exhibited more gutta-percha filled area in the canal which led to decreased apical leakage than Ultrafil 3D and lateral condensation techniques, proving to be more effective in achieving a complete three-dimensional apical seal.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA