1.
Small ; 19(10): e2206623, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36534833

RESUMO

Photoresponsive phase change materials (PPCMs) are capable of storing photon and heat energy simultaneously and releasing the stored energy as heat in a controllable way. While, the azobenzene-based PPCMs exhibit a contradiction between gravimetric energy storage density and photoinduced phase change. Here, a type of azobenzene surfactants with balance between molecular free volume and intermolecular interaction is designed in molecular level, which can address the coharvest of photon energy and low-grade heat energy at room temperature. Such PPCMs gain the total gravimetric energy density up to 131.18 J g-1 by charging solid sample and 160.50 J g-1 by charging solution. Notably, the molar isomerization enthalpy upgrades by a factor of up to 2.4 compared to azobenzene. The working mechanism is explained by the computational studies. All the stored energy can release out as heat under Vis light, causing a fast surface temperature rise. This study demonstrates a new molecular designing strategy for developing azobenzene-based PPCMs with high gravimetric energy density by improving the photon energy storage.

2.
Sensors (Basel) ; 23(21)2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37960611

RESUMO

The uneven energy response of radiation detectors severely limits the accuracy of the dose rate meter used for radiation protection. Currently widely used in dose rate meters as a physical method of setting shielding compensation, the energy response correction error of the detector at different energies is mostly between 15 and 25%. This work designs a real-time correction method for energy response based on a novel Cs3Cu2I5:Tl scintillation detector to improve the accuracy of the dose rate meter used for radiation protection. The technique utilizes the idea of pulse amplitude weighting (PAW) to segment the pulse amplitude histogram. This detector achieves an almost constant energy response after our correction. The experimental results show that compared to 137Cs γ rays, the maximum error of the response is 8.26% in the photon energy ranging from 33 keV to 1.25 MeV, which is much better than ±30% of the recommended IEC 61526:2010, verifying the feasibility of PAW.

3.
J Synchrotron Radiat ; 29(Pt 6): 1407-1413, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36345748

RESUMO

X-ray diffraction with high spatial resolution is commonly used to characterize (poly)crystalline samples with, for example, respect to local strain, residual stress, grain boundaries and texture. However, the investigation of highly absorbing samples or the simultaneous assessment of high-Z materials by X-ray fluorescence have been limited due to the utilization of low photon energies. Here, a goniometer-based setup implemented at the P06 beamline of PETRA III that allows for micrometre spatial resolution with a photon energy of 35 keV and above is reported. A highly focused beam was achieved by using compound refractive lenses, and high-precision sample manipulation was enabled by a goniometer that allows up to 5D scans (three rotations and two translations). As experimental examples, the determination of local strain variations in martensitic steel samples with micrometre spatial resolution, as well as the simultaneous elemental distribution for high-Z materials in a thin-film solar cell, are demonstrated. The proposed approach allows users from the materials-science community to determine micro-structural properties even in highly absorbing samples.

4.
J Synchrotron Radiat ; 29(Pt 5): 1152-1156, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36073873

RESUMO

A method to optimize the notches of water-cooled white-beam mirrors over the entire photon energy range is proposed. A theoretical method is used to quantitatively evaluate the influence of the thermal load on the thermal deformation of a mirror. The result of theoretical calculations and finite-element analysis are consistent, which proves the feasibility of the method. The root mean square of the curvatures of the thermal deformation of the white-beam mirror over the entire photon energy range can be minimized. This method greatly simplifies the design work of water-cooled white-beam mirrors.

5.
Macromol Rapid Commun ; 43(15): e2200070, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35298093

RESUMO

For utilizing organic solar cells (OSCs) for commercial applications, reducing the overall cost of the photo absorbent materials is also very crucial. Herein, such a challenge is addressed by synergistically controlling the amount of fluorine (F)-substituents (n = 2, 4) on a low-cost wide-bandgap molecular design involving alternate fluorinated-thienyl benzodithiophene donor and 2,5-difluoro benzene (2FBn) or 2,3,5,6 tetrafluorobenzene (4FBn) to form two new polymer donors PBDT-2FBn and PBDT-4FBn, respectively. As expected, sequential fluorination causes a lowering of the frontier energy levels and planarization of polymer backbone via F···S and C-H···F noncovalent molecular locks, which results in more pronounced molecular packing and enhanced crystallinity from PBDT-2FBn to PBDT-4FBn. By mixing with IT-4F acceptor, PBDT-2FBn:IT-4F-based blend demonstrates favorable molecular orientation with shorter π-π stacking distance, higher carrier mobilities and desirable nanoscale morphology, hence delivering a higher power conversion efficiency (PCE) of 9.3% than PBDT-2FBn:IT-4F counterpart (8.6%). Furthermore, pairing PBDT-2FBn with BTP-BO-4Cl acceptor further improved absorption range and promoted privileged morphology for efficient exciton dissociation and charge transport, resulting in further improvement of PCE to 10.2% with remarkably low energy loss of 0.46 eV. Consequently, this study provides valuable guidelines for designing efficient and low-cost polymer donors for OSC applications.

6.
Environ Geochem Health ; 44(9): 2943-2953, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35064382

RESUMO

Gallium oxide (Ga2O3), titanium dioxide (TiO2), cerium dioxide (CeO2), indium oxide (In2O3) and cadmium sulfide (CdS) were commonly used under UV light as photocatalysis system for the pollutants' degradation. In this study, these five catalysts were applied for the photodegradation of perfluorooctanoic acid (PFOA), a well-known perfluoroalkyl substance (PFAS). As a result, the PFOA photodegradation performance was sequenced as: Ga2O3 > TiO2 > CeO2 > In2O3 > CdS. To further explain the photocatalysis mechanism, the effects of initial pH, photon energy and band gap were evaluated. The initial pH of 3 ± 0.2 hinders the catalytic reaction of CdS, resulting in low degradation of PFOA, while it has no significant effect on Ga2O3, TiO2, CeO2 and In2O3. In addition, quantum yield was sequenced as TiO2 > CeO2 > Ga2O3 > In2O3, which may not be the main factor determining the degradation effect. Notably, the band gap energy from large to narrow was as: Ga2O3 > TiO2 > CeO2 > In2O3 > CdS, which exactly matched their degradation performance.


Assuntos
Fluorocarbonos , Compostos de Cádmio , Caprilatos , Sulfetos , Titânio/química , Água
7.
J Synchrotron Radiat ; 28(Pt 5): 1620-1630, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34475309

RESUMO

FinEstBeAMS (Finnish-Estonian Beamline for Atmospheric and Materials Sciences) is a multidisciplinary beamline constructed at the 1.5 GeV storage ring of the MAX IV synchrotron facility in Lund, Sweden. The beamline covers an extremely wide photon energy range, 4.5-1300 eV, by utilizing a single elliptically polarizing undulator as a radiation source and a single grazing-incidence plane grating monochromator to disperse the radiation. At photon energies below 70 eV the beamline operation relies on the use of optical and thin-film filters to remove higher-order components from the monochromated radiation. This paper discusses the performance of the beamline, examining such characteristics as the quality of the gratings, photon energy calibration, photon energy resolution, available photon flux, polarization quality and focal spot size.

8.
Macromol Rapid Commun ; 42(9): e2000743, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33644922

RESUMO

Design and development of wide bandgap (WBG) polymer donors with low-lying highest occupied molecular orbitals (HOMOs) are increasingly gaining attention in non-fullerene organic photovoltaics since such donors can synergistically enhance power conversion efficiency (PCE) by simultaneously minimizing photon energy loss (Eloss ) and enhancing the spectral response. In this contribution, three new WBG polymer donors, P1, P2, and P3, are prepared by adding phenylene cores with a different number of fluorine (F) substituents (n = 0, 2, and 4, respectively) to dicarboxylate bithiophene-based acceptor units. As predicted, fluorination effectively aides in the lowering of HOMO energy levels, tailoring of the coplanarity and molecular ordering in the polymers. Thus, fluorinated P2 and P3 polymers show higher coplanarity and more intense interchain aggregation than P1, leading to higher charge carrier mobilities and superior phase-separated morphology in the optimized blend films with IT-4F. As a result, both P2:IT-4F and P3:IT-4F realize the best PCEs of 6.89% and 7.03% (vs 0.16% for P1:IT-4F) with lower Eloss values of 0.65 and 0.55 eV, respectively. These results signify the importance of using phenylene units with sequential fluorination in polymer backbone for modifying the optoelectronic properties and realizing low Eloss values by synergistically lowering the HOMO energy levels.


Assuntos
Energia Solar , Ácidos Carboxílicos , Fontes de Energia Elétrica , Halogenação , Polímeros
9.
J Appl Clin Med Phys ; 22(1): 76-91, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33270985

RESUMO

PURPOSE: To investigate the effect of an integral quality monitor (IQM; iRT Systems GmbH, Koblenz, Germany) on 4, 6, 10, and 6-MV flattening filter-free (FFF) photon beams. METHODS: We assessed surface dose, PDD20,10 , TPR20,10 , PDD curves, inline and crossline profiles, transmission factor, and output factor with and without the IQM. PDD, transmission factor, and output factor were measured for square fields of 3, 5, 10, 15, 20, 25, and 30 cm and profiles were performed for square fields of 3, 5, 10, 20, and 30 cm at 5-, 10-, and 30-cm depth. RESULTS: The differences in surface dose of all energies for square fields of 3, 5, 10, 15, 20, and 25 cm were within 3.7% whereas for a square field of 30 cm, they were 4.6%, 6.8%, 6.7%, and 8.7% for 4-MV, 6-MV, 6-MV-FFF, and 10-MV, respectively. Differences in PDD20,10 , TPR20,10 , PDD, profiles, and output factors were within ±1%. Local and global gamma values (2%/2 mm) were below 1 for PDD beyond dmax and inline/crossline profiles in the central beam region, respectively. The gamma passing rates (10% threshold) for PDD curves and profiles were above 95% at 2%/2 mm. The transmission factors for 4-MV, 6-MV, 6-MV-FFF, and 10-MV for field sizes from 3 × 3 to 30 × 30 cm2 were 0.926-0.933, 0.937-0.941, 0.937-0.939, and 0.949-0.953, respectively. CONCLUSIONS: The influence of the IQM on the beam quality (in particular 4-MV X-ray has not verified before) was tested and introduced a slight beam perturbation at the surface and build-up region and the edge of the crossline/inline profiles. To use IQM in pre- and intra-treatment quality assurance, a tray factor should be put into treatment planning systems for the dose calculation for the 4-, 6-, 10-, and 6-MV flattening filter-free photon beams to compensate the beam attenuation of the IQM detector.


Assuntos
Aceleradores de Partículas , Radiometria , Humanos , Fótons
10.
Sensors (Basel) ; 21(6)2021 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-33801111

RESUMO

Aero-optical effects reduce the accuracy of optical sensors on high-speed aircraft. Current research usually focuses on light refraction caused by large-scale density structures in turbulence. A method for analyzing photon energy scattering caused by micro-scale structures is proposed in this paper, which can explain the macro image distortion caused by moving molecules in inhomogeneous airflow. Quantitative analysis of the propagation equation indicates that micro-scale structures may contribute more to the wavefront distortion than the widely considered large-scale structures. To analyze the micro mechanism of aero-optical effects, a transient simulator is designed based on the scaling model of transient distorted wavefronts and the artificial vortex structure. The simulation results demonstrate that correct aero-optical phenomena can be obtained from the micro mechanism of photon energy scattering. Examples of using the transient simulator to optimize the parameters of the star sensor on a hypersonic vehicle are provided. The proposed analysis method for micro-scale structures provides a new idea for studying the aero-optical effects.

11.
J Xray Sci Technol ; 28(4): 641-658, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32390644

RESUMO

OBJECTIVE: Several physical factors such as dose rate and photon energy may change response and sensitivity of polymer gel dosimeters. This study aims to evaluate the R2-dose response and sensitivity dependence of PASSAG-U gel dosimeters with 3% and 5% urea on dose rate and photon energy. MATERIALS AND METHODS: The PASSAG-U gel dosimeters were prepared under normal atmospheric conditions. The obtained gel dosimeters were irradiated to different dose rates (100, 200, and 300 cGy/min) and photon energies (6 and 15 MV). Finally, responses (R2) of the PASSAG-U gel dosimeters with 3% and 5% urea were analyzed by MRI technique at 1, 10, 14 days after the irradiation process. RESULTS: The findings showed that the R2-dose responses of PASSAG-U gel dosimeters with 3% and 5% urea do not vary under the differently evaluated dose rates and photon energies. The R2-dose sensitivity of PASSAG-U polymer gel dosimeter with 3% urea does not change under the differently evaluated dose rates and photon energies, but it changes for PASSAG-U polymer gel dosimeter with 5% urea. The dose resolution values ranged from 0.20 to 0.86 Gy and from 0.27 to 2.20 Gy for the PASSAG-U gel dosimeter with 3% and 5% urea for the different dose rates and photon energies, respectively. Furthermore, it was revealed that the R2-dose response and sensitivity dependence of PASSAG-U gel dosimeters with 3% and 5% urea on dose rate and photon energy can vary over post irradiation time. CONCLUSIONS: The study results demonstrated that dosimetric characteristics (dependence of dose rate and photon energy, and dose resolution) of PASSAG-U gel dosimeter with 3% were better than those of PASSAG-U gel dosimeter with 5% urea.


Assuntos
Dosímetros de Radiação , Relação Dose-Resposta à Radiação , Géis , Imageamento por Ressonância Magnética , Fótons , Polímeros , Doses de Radiação , Radiometria , Sensibilidade e Especificidade , Ureia/análise
12.
Rep Pract Oncol Radiother ; 22(1): 1-9, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27790072

RESUMO

AIM: Aim of the present study was to compare the dosimetric impact of different photon beam energies and number of arcs in the treatment of carcinoma cervix. BACKGROUND: Carcinoma cervix is a common cancer in women worldwide with a high morbidity rate. Radiotherapy is used to treat such tumours. Volumetric Modulated Arc Therapy (VMAT) is considered superior to other techniques with multiple arcs and energies. MATERIALS AND METHODS: Twenty patients with carcinoma cervix underwent radiotherapy in a prospective observation study conducted at our institute. Volumetric modulated arc plans with 6 MV, 10 MV and 15 MV photon energies using single arc (SA) and dual arc (DA) were generated. Several physical indices for planning target volume (PTV) like V95%, V100%, V110%, D98%, D50%, D2% and total number of MUs were compared. Normal Tissue Integral Dose (NTID) and dose to a shell structure PHY2.5 and PHY5.0 were analyzed. RESULTS: Comparable dose coverage to PTV was observed for all the energies and arcs. CI for DA6MV (1.095) was better than SA6MV (1.127), SA10MV (1.116) and SA15MV (1.116). Evaluated parameters showed significant reduction in OAR doses. Mean bladder dose for DA6MV (41.90 Gy) was better than SA6MV (42.48 Gy), SA10MV (42.08 Gy) and SA15MV (41.93 Gy). Similarly, p-value for the mean rectal dose calculated was 0.001 (SA6 vs 15), 0.013 (DA6 vs 10) and 0.003 (DA6 vs 15) and subsequently favoured DA6MV. Difference in NTID was very small. CONCLUSIONS: The study showed no greater advantage of higher energy, and DA VMAT plan with 6 MV photon energy was a good choice of treatment for carcinoma cervix as it delivered a highly homogeneous and conformal plan with superior target coverage and better OAR sparing.

13.
J Synchrotron Radiat ; 23(1): 35-42, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26698043

RESUMO

Measurement of the emission wavelength and the spectral content of the photon radiation is essential information for both machine and experimental physicists at a free-electron laser (FEL) user facility. Knowledge of the photon beam spectral properties is needed during the machine optimization and for performing machine studies (i.e. monitoring the change of the FEL output as a function of the machine parameters). The experimentalists, on the other hand, need to know the photon beam spectral distribution of the source, shot to shot, to discriminate the acquired data. Consequently, the main requirement for the instrument, supposed to obtain this information, is the capability of working on-line and shot-to-shot, with minimal perturbation of the beam delivered to the experimental stations. Starting from the grating fundamental equations, the conceptual design of the FERMI Pulse-Resolved Energy Spectrometer: Transparent and On-line (PRESTO) is presented, explaining the optical design in detail. The performance of PRESTO, in terms of resolving power, efficiency and spectral response, is also discussed. Finally, some useful features beyond the usual measurement of the energy spectrum are reported, as they have been routinely used by both machine and experimental physicists.

14.
J Synchrotron Radiat ; 23(1): 98-105, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26698050

RESUMO

The future Magneto Dynamics (MagneDyn) beamline will be devoted to study the electronic states and the local magnetic properties of excited and transient states of complex systems by means of the time-resolved X-ray absorption spectroscopy technique. The beamline will use FERMI's high-energy source covering the wavelength range from 60 nm down to 1.3 nm. An on-line photon energy spectrometer will allow spectra to be measured with high resolution while delivering most of the beam to the end-stations. Downstream the beam will be possibly split and delayed, by means of a delay line, and then focused with a set of active Kirkpatrick-Baez mirrors. These mirrors will be able to focus the radiation in one of the two MagneDyn experimental chambers: the electromagnet end-station and the resonant inelastic X-ray scattering end-station. After an introduction of the MagneDyn scientific case, the layout will be discussed showing the expected performances of the beamline.

15.
Radiol Oncol ; 50(2): 238-46, 2016 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27247558

RESUMO

AIM: The aim of this study is to quantify the influence of the photon energy spectrum of brachytherapy sources on task group No. 43 (TG-43) dosimetric parameters. BACKGROUND: Different photon spectra are used for a specific radionuclide in Monte Carlo simulations of brachytherapy sources. MATERIALS AND METHODS: MCNPX code was used to simulate 125I, 103Pd, 169Yb, and 192Ir brachytherapy sources. Air kerma strength per activity, dose rate constant, radial dose function, and two dimensional (2D) anisotropy functions were calculated and isodose curves were plotted for three different photon energy spectra. The references for photon energy spectra were: published papers, Lawrence Berkeley National Laboratory (LBNL), and National Nuclear Data Center (NNDC). The data calculated by these photon energy spectra were compared. RESULTS: Dose rate constant values showed a maximum difference of 24.07% for 103Pd source with different photon energy spectra. Radial dose function values based on different spectra were relatively the same. 2D anisotropy function values showed minor differences in most of distances and angles. There was not any detectable difference between the isodose contours. CONCLUSIONS: Dosimetric parameters obtained with different photon spectra were relatively the same, however it is suggested that more accurate and updated photon energy spectra be used in Monte Carlo simulations. This would allow for calculation of reliable dosimetric data for source modeling and calculation in brachytherapy treatment planning systems.

16.
Radiat Oncol ; 19(1): 1, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38167095

RESUMO

SBRT is an effective local treatment for patients with early-stage non-small cell lung cancer (NSCLC). This treatment is currently used in patients who have poor lung function or who decline surgery. As SBRT usually has small PTV margins, reducing the beam-on-time (BOT) is beneficial for accurate dose delivery by minimising intrafraction motion as well as improved patient comfort. Removal of the linear accelerator flattening filter can provide a higher dose rate which results in a faster treatment. In addition, the choice of photon energy can also affect the dose distribution to the target and the organs-at-risk (OAR). In this systematic review, studies analysing the choice of various photon beam energies, with a flattening filter or flattening filter free (FFF), were compared for their overall dosimetric benefit in the SBRT treatment for early-stage NSCLC. It was found that FFF treatment delivers a comparatively more conformal dose distribution, as well as a better homogeneity index and conformity index, and typically reduces BOT by between 30 and 50%. The trade-off may be a minor increase in monitor units for FFF treatment found in some studies but not others. Target conformity and OAR sparing, particularly lung doses appear better with 6MV FFF, but 10MV FFF was marginally more advantageous for skin sparing and BOT reduction. The favourable beam modality for clinical use would depend on the individual case, for which tumour size and depth, radiotherapy technique, as well as fractionation scheme need to be taken into account.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Radiocirurgia , Radioterapia de Intensidade Modulada , Carcinoma de Pequenas Células do Pulmão , Humanos , Radiocirurgia/métodos , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Carcinoma Pulmonar de Células não Pequenas/patologia , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Neoplasias Pulmonares/patologia , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Pulmão/patologia , Carcinoma de Pequenas Células do Pulmão/cirurgia , Dosagem Radioterapêutica
17.
ACS Sens ; 9(3): 1584-1591, 2024 03 22.
Artigo em Inglês | MEDLINE | ID: mdl-38450591

RESUMO

Chemoresistive gas sensors made from SnO2, ZnO, WO3, and In2O3 have been prepared by flame spray pyrolysis. The sensors' response to CO and NO2 in darkness and under illumination at different wavelengths, using commercially available LEDs, was investigated. Operation at room temperature turned out to be impractical due to the condensation of water inside the porous sensing layers and the irreversible changes it caused. Accordingly, for sensors operated at 70 °C, a characterization procedure was developed and proven to deliver consistent data. The resulting data set was so complex that usual univariate data analysis was intricate and, consequently, was investigated by correlation and principal component analysis. The results show that light of different wavelengths affects not only the resistance of each material, both under exposure to the target gases in humidity and in its absence, but also the sensor response to humidity and the target gases. It was found that each of the materials behaves differently under light exposure, and it was possible to identify conditions that need further investigations.


Assuntos
Gases , Análise Multivariada , Umidade , Porosidade , Análise de Componente Principal
18.
Phys Med ; 82: 122-133, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33611049

RESUMO

PURPOSE: The purpose of this work was to present a new single-arc mixed photon (6&18MV) VMAT (SAMP) optimization framework that concurrently optimizes for two photon energies with corresponding partial arc lengths. METHODS AND MATERIALS: Owing to simultaneous optimization of energy dependent intensity maps and corresponding arc locations, the proposed model poses nonlinearity. Unique relaxation constraints based on McCormick approximations were introduced for linearization. Energy dependent intensity maps were then decomposed to generate apertures. Feasibility of the proposed framework was tested on a sample of ten prostate cancer cases with lateral separation ranging from 34 cm (case no.1) to 52 cm (case no.6). The SAMP plans were compared against single energy (6MV) VMAT (SE) plans through dose volume histograms (DVHs) and radiobiological parameters including normal tissue complication probability (NTCP) and equivalent uniform dose (EUD). RESULTS: The contribution of higher energy photon beam optimized by the algorithm demonstrated an increase for cases with a lateral separation >40 cm. SAMP-VMAT notably improved bladder and rectum sparing in large size cases. Compared to single energy, SAMP-VMAT plans reduced bladder and rectum NTCP in cases with large lateral separation. With the exception of one case, SAMP-VMAT either improved or maintained femoral heads compared to SE-VMAT. SAMP-VMAT reduced the nontarget tissue integral dose in all ten cases. CONCLUSIONS: A single-arc VMAT optimization framework comprising mixed photon energy partial arcs was presented. Overall results underline the feasibility and potential of the proposed approach for improving OAR sparing in large size patients without compromising the target homogeneity and coverage.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Humanos , Masculino , Fótons , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
19.
In Vivo ; 35(6): 3147-3155, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34697145

RESUMO

BACKGROUND/AIM: The quantitative evaluation of fat tissue, mainly for the determination of liver steatosis, is possible by using dual-energy computed tomography. Different photon energy acquisitions allow for estimation of attenuation coefficients. The effect of variation in radiation doses and reconstruction kernels on fat fraction estimation was investigated. MATERIALS AND METHODS: A six-probe-phantom with fat concentrations of 0%, 20%, 40%, 60%, 80%, and 100% were scanned in Sn140/100 kV with radiation doses ranging between 20 and 200 mAs before and after calibration. Images were reconstructed using iterative kernels (I26,Q30,I70). RESULTS: Fat fractions measured in dual-energy computed tomography (DECT) were consistent with the 20%-stepwise varying actual concentrations. Variation in radiation dose resulted in 3.1% variation of fat fraction. Softer reconstruction kernel (I26) underestimated the fat fraction (-9.1%), while quantitative (Q30) and sharper kernel (I70) overestimated fat fraction (10,8% and 13,1, respectively). CONCLUSION: The fat fraction in DECT approaches the actual fat concentration when calibrated to the reconstruction kerneö. Variation of radiation dose caused an acceptable 3% variation.


Assuntos
Fígado Gorduroso , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Fótons , Doses de Radiação
20.
Materials (Basel) ; 14(5)2021 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-33806446

RESUMO

Conjugated donor-acceptor molecules with intramolecular charge transfer absorption are employed for single-component organic solar cells. Among the five types of donor-acceptor molecules, the strong push-pull structure of DTDCPB resulted in solar cells with high JSC, an internal quantum efficiency exceeding 20%, and high VOC exceeding 1 V with little photon energy loss around 0.7 eV. The exciton binding energy (EBE), which is a key factor in enhancing the photocurrent in the single-component device, was determined by quantum chemical calculation. The relationship between the photoexcited state and the device performance suggests that the strong internal charge transfer is effective for reducing the EBE. Furthermore, molecular packing in the film is shown to influence photogeneration in the film bulk.