Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.086
Filtrar
1.
Braz. dent. sci ; 26(4): 1-10, 2023. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1523773

RESUMO

Objective: The aim of the study was to evaluate the short and long-term effects of different surface treatments on the bond strengths of zirconia. Material and Methods: 225 blocks of sintered zirconia samples (4 x 4 x 3 mm) were divided into five groups and subjected to different surface treatments: control group (without surface treatment), alumina group (sandblasting [25-µm-aluminum-oxide]), alumina+Ambar Universal-APS (AU) group, CoJet group (silica-coated [30-µm silica-modified aluminum particles]), and CoJet+AU group. Subsequently, zirconia samples were cemented against resin samples (total dimensions: 8x8x6mm) and assigned to three storage conditions: dry, humid (artificial saliva at 37°C for 30-days) or thermocycling [100.000-cycles] (n=15 per group). The microtensile bond strength (µTBS) was determined using a universal testing machine. The failure modes were observed and analyzed using a stereomicroscope. Normality tests, descriptive statistics, and two-way ANOVA, followed by post-hoc comparisons, were performed to evaluate the effect of surface treatments and storage conditions on µTBS (α=0.05). Results: µTBS was influenced by surface treatment in the short and long-term (P<0.0001). The highest values were found in CoJet+AU in dry (33.51 ±2.48 MPa), humid (32.87 ±2.68 MPa) and thermocycling (21.37 ±1.68 MPa) storage conditions compared with others. Interestingly, no significant differences in µTBS were found among alum +AU and CoJet alone under any of the three storage conditions. Adhesive failure increased in all groups after thermocycling, but CoJet+AU had the lowest values of adhesive failure compared with others. Conclusion: The combination of CoJet and Ambar universal as a surface treatment for zirconia specimens provides significantly higher short and long-term bond strengths of adhesive cementation (AU)


Objetivo: O objetivo do estudo foi avaliar os efeitos de curto e longo prazo de diferentes tratamentos de superfície na resistência de adesão da zircônia. Material e Métodos: 225 blocos de amostras de zircônia sinterizada (4 x 4 x 3 mm) foram divididos em cinco grupos e submetidos a diferentes tratamentos de superfície: grupo controle (sem tratamento de superfície), grupo de alumina (jateamento de 25 µm de óxido de alumínio), grupo alumina+Ambar Universal-APS (AU), grupo CoJet (partículas de alumínio modificadas por sílica de 30 µm), e grupo CoJet+AU. Posteriormente, as amostras de zircônia foram cimentadas em amostras de resina (dimensões totais: 8x8x6mm) e designadas para três condições de armazenamento: seco, úmido (saliva artificial a 37°C por 30 dias) ou ciclagem térmica (100.000 ciclos) (n=15 por grupo). A resistência de adesão de microtensão (µTBS) foi determinada usando uma máquina de teste universal. Os modos de falha foram observados e analisados usando um estereomicroscópio. Testes de normalidade, estatísticas descritivas e ANOVA de duas vias, seguidas de comparações pos-hoc, foram realizados para avaliar o efeito dos tratamentos de superfície e das condições de armazenamento na µTBS (α=0.05). Resultados: A µTBS foi influenciada pelo tratamento de superfície a curto e longo prazo (P<0.0001). Os valores mais altos foram encontrados em CoJet+AU nas condições de armazenamento a seco (33.51 ±2.48 MPa), úmido (32.87 ±2.68 MPa) e ciclagem térmica (21.37 ±1.68 MPa) em comparação com os outros. Curiosamente, não foram encontradas diferenças significativas na µTBS entre alum +AU e CoJet sozinho em nenhuma das três condições de armazenamento. A falha adesiva aumentou em todos os grupos após a ciclagem térmica, mas CoJet+AU teve os valores mais baixos de falha adesiva em comparação com os outros. Conclusão: A combinação de CoJet e Ambar Universal como tratamento de superfície para espécimes de zircônia proporciona resistências de adesão significativamente mais altas a curto e longo prazo para cimentação adesiva. (AU)


Assuntos
Cimentos Dentários
2.
Braz. dent. sci ; 26(4): 1-10, 2023. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1523860

RESUMO

Objective: The aim of this in vitro study w as t o analyze the influence of the titanium dioxide nanotubes i n a self-cure mode polymerization of a dual resin luting agent through push out bond strength and radiopacity tests. Material and Methods: After mixed with a commercial du al self-adhesive resin cement, three concentrations o f tit anium dioxide nanotubes (0.3, 0.6, and 0.9% by weight) we re analyzed in self-curing mode. T he bond strength to bovine root dentin and fi berglass posts was assessed with the push out bond str ength t est and was evaluated in three thirds (cervical, middle and apical) (n=10), followed by failure mode analysis (SEM), and the ISO standard 9917-2 was followed for radiopacity test (n=10). Data were statistically analyzed by one-way ANOVA test, followed by Tukey's test (α=0.05). Results: Reinforced self-adhesive resin cement with 0.6% titanium dioxide nanotubes showed significant difference compared to the control gr oup for push out test (p=0.00158). The modified groups did not s how significant difference among thirds (p=0.782). Radiopacity sh owed higher value for group w ith 0.9% titanium dioxide nanotubes in comparison w ith control group (p<0.001). Conclusion: The addition of titanium dioxide nanotubes to a self-adhesive resin cement increased the bond strength to dentin and radiopacity values in the self-cure polymerization mode (AU)


Objetivo: O objetivo deste estudo in vitro foi analisar a influência de nanotubos de dióxido de titânio na polimerização química de um agente cimentante resinoso dual através de testes de resistência à união e radiopacidade. Material e Métodos: Após misturado com um cimento resinoso auto-adesivo comercial, três concentrações de nanotubos de dióxido de titânio (0,3, 0,6 e 0,9% em peso) foram analisadas. A resistência da união para a dentina da raiz bovina e os pinos de fibra de vidro foi avaliada pelo teste de push-out e avaliada em três terços (cervical, médio e apical) (n = 10), seguido pelo análise de modo de falha (MEV) e a norma ISO 9917-2 foi seguido para teste de radiopacidade (n = 10). Os dados foram analisados estatisticamente pelo teste ANOVA um fator seguido do teste de Tukey (α = 0,05). Resultados: O cimento resinoso auto-adesivo reforçado com nanotubos de dióxido de titânio a 0,6% mostrou diferença significativa em comparação com o grupo controle para teste de push-out (p=0,00158). Os grupos modificados não mostraram diferença significativa entre os terços (p=0,782). A radiopacidade mostrou maior valor para o grupo com nanotubos de dióxido de titânio 0,9% em comparação com o grupo controle (p<0,001). Conclusão: A adição de nanotubos de dióxido de titânio a um cimento resinoso auto-adesivo aumentou a os valores de resistência de união à dentina e radiopacidade no modo de polimerização química do agente cimentante (AU)


Assuntos
Titânio , Cimentos Dentários , Pinos Dentários , Nanotubos
3.
Braz. j. oral sci ; 22: e239056, Jan.-Dec. 2023. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1443592

RESUMO

Aim: This review investigated the effect of applying an adhesive after surface treatment of glass-ceramics on the bonding, mechanical or clinical behavior. Methods: Studies comparing the adhesive, mechanical or clinical behavior of glass-ceramics, with or without adhesive application after surface treatment, were included. Searches were performed in PubMed, Scopus, and Web of Sciences databases (January 2022), resulting in 15 included studies. Results: Regarding the evaluated outcomes, 13 studies assessed bond strength, 2 studies assessed biaxial flexural strength and 1 study assessed fatigue failure load, while no study evaluating clinical outcomes was included. It was possible to observe that the adhesive application after ceramic surface treatment was unfavorable or did not influence the evaluated outcomes. Conclusion: Most of the evidence available in the literature shows that the adhesive application after surface treatment does not improve the adhesive and mechanical behavior of glass-ceramics


Assuntos
Cerâmica , Cimentos Dentários , Resistência à Flexão
4.
Rev. odontol. UNESP (Online) ; 52: e20230035, 2023. tab, ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1530306

RESUMO

Introdução: Cimentos endodônticos à base de silicato de cálcio demonstram maior solubilidade em água destilada. Emprego de metodologias alternativas pode auxiliar em melhor compreensão sobre a solubilidade desses materiais. Objetivo: Avaliar o efeito da solução de imersão e do tipo de modelo experimental na solubilidade de cimento pronto para uso Bio-C Sealer. Material e método: Modelos circulares de polietileno ou dentina bovina (n = 16) foram confeccionados. Após inserção do cimento, os espécimes foram mantidos em estufa a 37 °C por 48 horas. Posteriormente, as amostras foram pesadas em balança de precisão para determinação da massa inicial. Na sequência, os espécimes foram imersos em 7,5 mL de água destilada (pH 6,5) ou PBS (pH 7,0) (n = 8) por 28 dias. Após isso, as amostras foram removidas das soluções e pesadas a cada 24 horas até a estabilização da massa final (0,001g). Corpos de prova confeccionados com Bio-C Sealer foram empregados como controle. A solubilidade foi avaliada de acordo com a diferença entre a massa inicial e final em porcentagem. Teste ANOVA Two-Way e teste post-hoc de Tukey foram realizados (α = 0,05). Resultado: Imersão em água destilada proporcionou maior solubilidade em comparação com PBS, independentemente do modelo experimental (p < 0,05). Corpos de prova apresentaram maior solubilidade, seguidos dos modelos de polietileno e dentina imersos em água destilada (p < 0,05). Não houve diferença entre os modelos experimentais imersos em PBS (p > 0,05). Conclusão: Bio-C Sealer apresenta solubilidade significativamente maior em água destilada do que em PBS em todas condições. Modelo experimental empregando dentina bovina e PBS como solução de imersão demonstra diminuir a perda de massa de Bio-C Sealer e pode ser uma alternativa valiosa para avaliar a solubilidade de cimentos biocerâmicos


Introduction: Calcium silicate-based sealers demonstrate greater solubility in distilled water. The use of alternative methodologies can help at better understanding the solubility of these materials. Objective: To evaluate the effect of the immersion solution and the type of experimental model on the solubility of readyto-use Bio-C Sealer. Material and method: Circular models of polyethylene or bovine dentin (n = 16) were made. After insertion of the sealer, the specimens were kept in an oven at 37°C and 95% humidity for 48h. Subsequently, the samples were weighed on a precision balance to determine the initial mass. Next, the specimens were immersed in 7.5 mL of distilled water (pH 6.5) or PBS (pH 7.0) (n = 8) for 28 days. After that, the samples were removed from the solutions and weighed every 24 hours until the final mass stabilized (0.001g). Test specimens made with Bio-C Sealer were used as a control. Solubility was evaluated according to the difference between the initial and final mass in percentage. Two-Way ANOVA test and Tukey post-hoc tests were performed (α=0.05). Result: Immersion in distilled water provided greater solubility compared to PBS regardless of the experimental model (p<0.05). The test specimens showed greater solubility, followed by polyethylene and dentin models immersed in distilled water (p<0.05). There was no difference between the experimental models immersed in PBS (p>0.05). Conclusion: Bio-C Sealer presents significantly greater solubility in distilled water than in PBS under all conditions. Experimental model using bovine dentin and PBS as an immersion solution demonstrates reduction in the mass loss of Bio-C Sealer and can be a valuable alternative for evaluating the solubility of bioceramic sealers


Assuntos
Bovinos , Solubilidade , Água Destilada , Calcarea Silicata , Análise de Variância , Dentina , Fenômenos Físicos , Cimentos Dentários
5.
São José dos Campos; s.n; 2023. 67 p. ilus, tab.
Tese em Português | BBO - Odontologia | ID: biblio-1435875

RESUMO

O presente estudo teve como objetivo caracterizar a microestrutura de uma resina temporária de impressão 3D (Resilab Temp), avaliando as propriedades óticas, o comportamento mecânico e a resistência à tração de coroas cimentadas com diferentes cimentos temporários. Todas as propriedades foram também avaliadas após a simulação de envelhecimento térmico. Para a análise da microestrutura superficial e estabelecimento do melhor padrão de impressão, amostras em formato de barras seguindo a ISO 4049 (25 x 10 x 3 mm) foram desenhadas em software (Rhinoceros 6.0), impressas na impressora W3D (Wilcos do Brasil) e fotopolimerizadas na Anycubic Photon em diferentes tempos (sem cura, 16 minutos, 32 minutos e 1 hora). Para a caracterização estrutural foram realizadas as análises em FTI-R (Espectroscopia de infravermelho com transformada de Fourier) e Microscopia Eletrônica de Varredura (MEV). O comportamento mecânico da resina foi feito com base nos testes de resistência à flexão, mensuração do módulo elástico e microdureza de Knoop. A análise de cor e translucidez foi feita com um espectrofotômetro (VITA Easy shade Advanced 4.0), o qual foi avaliado seguindo o CIELab, utilizando os fundos cinza, preto e branco. Todas as análises foram realizadas imediatamente após a confecção das amostras e repetidas após o envelhecimento térmico com 2 mil ciclos (5-55 C). Coroas de resinas foram fabricados da mesma forma que os espécimes anteriores e foram cimentadas sobre preparo padronizados em resina Nema G10 (análogo à dentina). Foram usados 3 cimentos temporários: hidróxido de cálcio (HC), óxido de zinco sem eugenol (OZNE) e ionômero de vidro (IOV). Os espécimes foram ensaiados com teste de resistência à tração das coroas, antes e após o mesmo envelhecimento térmico. Os resultados obtidos foram analisados estatisticamente com nível de significância de 5%. A análise de FTI-R mostrou cerca de 46% de grau de conversão na superfície e 37% no centro da amostra da resina. A resistência à flexão foi maior para os grupos polimerizados por 32 min e 1h, enquanto a microdureza Knoop não apresentou diferença estatística entre os grupos. A análise translucidez também não mostrou diferenças estatísticas entre os grupos, entretanto a cor foi alterada pelo tempo de polimerização e envelhecimento. No ensaio de resistência à tração, todos os fatores mostraram diferenças estatisticamente significantes. Antes do envelhecimento, o grupo IOV foi estatisticamente superior ao HC e OZNE; Entretanto, após o envelhecimento, não houve diferença entre os grupos. De acordo com todas as análises realizadas nesse estudo, o tempo de pós polimerização de 1 hora apresentou o melhor desempenho mecânico e estabilidade de cor, e o cimento de ionômero de vidro possui a melhor retenção imediata após a cimentação, apesar de todos os cimentos temporários usados no estudo possam ser indicados. (AU)


The present study aimed to characterize the microstructure of a 3D printing temporary resin (Resilab Temp), evaluating the optical properties, mechanical behavior and tensile strength of crowns cemented with different temporary cements. All properties were also evaluated after simulated thermal aging. For surface microstructure analysis, bar-shaped specimens following ISO 4049 (25 x 10 x 3 mm) were designed in software (Rhinoceros 6.0), printed in the W3D printer (Wilcos do Brasil) (n=36) and photopolymerized in the Anycubic Photon at different times (no curing, 16 minutes, 32 minutes and 1 hour). For structural characterization FTI-R (n=72) (Fourier transform infrared spectroscopy) and Scanning Electron Microscopy (SEM)(n=4) analyses were carried out. The mechanical behavior of the resin was done based on flexural strength tests, elastic modulus measurement (n=12) and Knoop microhardness (n=20). The color and translucency analysis was done with a spectrophotometer (n=40) (VITA Easy shade Advanced 4.0), which was evaluated following the CIELab, using the gray, black and white backgrounds. All analyses were performed immediately after making the samples and repeated after thermal aging with 2,000 cycles (5-55 C). Resin crowns were fabricated (n=48) in the same manner as the previous specimens and were cemented on standardized preparations in Nema G10 resin (dentin analog). Three temporary cements were used: calcium hydroxide (HC), zinc oxide without eugenol (OZNE) and glass ionomer (IOV). The specimens were tested with crown tensile strength test before and after the same thermal aging. The results obtained were statistically analyzed with 5% significance level. FTI-R analysis showed about 46% degree of conversion on the surface and 37% in the center of the resin sample. The flexural strength was higher for the groups polymerized for 32 min and 1h, while Knoop microhardness showed no statistical difference between groups. Translucency analysis also showed no statistical difference between groups, however the color was altered by polymerization time and aging. In the tensile strength test, all factors showed statistically significant differences. Before aging, the IOV group was statistically superior to HC and OZNE; however, after aging, there was no difference between the groups. According to all analyses performed in this study, the 1-hour post-curing time showed the best mechanical performance and color stability, and the glass ionomer cement has the best immediate retention after cementation, although all temporary cements used in the study can be indicated (AU)


Assuntos
Envelhecimento , Cor , Coroas , Cimentos Dentários , Impressão Tridimensional
6.
Natal; s.n; 04/08/2022. 66 p. tab, ilus, graf.
Tese em Português | BBO - Odontologia | ID: biblio-1510735

RESUMO

Este trabalho objetivou desenvolver, caracterizar e avaliar a atividade osteogênica de formulações de CP com diferentes proporções de óxido de Nióbio (Nb2O5), substituindo o Bi2O3. Foram utilizados três grupos, um controle e dois experimentais: GC (MTA Angelus®), F6 (75% CP, 20% Nb2O5 e 5% CaSO4) e F7 (75% CP, 10% Bi2O3, 10% Nb2O5e 5% CaSO4). As formulações foram submetidas às análises de Difração de RaioX (DRX), Microscopia Eletrônica de Varredura (MEV), Espectroscopia de Infravermelho com Transformada de Fourier (FTIR), Espectrometria de Fluorescência de Raios-X (FRX), pH, tempo de presa, radiopacidade, resistência a compressão, citotoxicidade e bioatividade. Os dados obtidos foram avaliados estatisticamente pelo teste de variância (ANOVA) com correção de Bonferroni (p<0,05%). O resultado do teste de pH: Nióbio 10% Imediato (12,205 ±0,304); 24h; (12,770 ± 0,226) 48h: (12,910 ± 0,169). Nióbio 20%: imediato (12,080 ± 0,282); 24 h: (12,350 ± 0,593); 48 h: (12,580 ± 0,73). Para o tempo de presa inicial em segundos: MTA (397,500 ±10,606); Nióbio 10% (294,333 + 90,897) e Nióbio 20% (279,000 + 15,874). O tempo de presa final para os grupos foram: MTA (15,000 + 49,497), Nióbio 10% (560 ±38,587), sendo menor quando comparado ao MTA (p<0,001) e Nióbio 20% (715,666 ± 30,664) (p<0,01). Os valores da radiopacidade em mm Al do Nióbio 10% (3,888 ±0,340); Nióbio 20% (3,713 ± 0,712). A resistência a compressão em MPa foi: Nióbio 10% (694,150 + 78,951) Nióbio 20% (699,295 + 47,672). A viabilidade celular não apresentou diferença entre o MTA e grupos experimentais (p<0,05). Os resultados da capacidade osteogênese das formulações a partir do ensaio da fosfatase alcalina (FAL) em UI/L por grama de proteína para cada grupo foi: MTA (1,9 + 1,227) e Nióbio 20% (1,784 + 1,342) (p>0,05). Nossos achados apontam propriedades relevantes para as formulações com Nb2O5 como, pH alcalino, radiopacidade, resistência a compressão e atividade da fosfatase alcalina (AU).


Work aimed to develop, characterize and evaluate the osteogenic activity of PC formulations with different proportions of Niobium oxide (Nb2O5), replacing Bi2O3. Three groups were used, one control and two experimental: GC (MTA Angelus®), F6 (75% CP, 20% Nb2O5 and 5% CaSO4) and F7 (75% CP, 10% Bi2O3, 10% Nb2O5e 5% CaSO4) . The formulations were submitted to X-ray Diffraction (XRD), Scanning Electron Microscopy (SEM), Fourier Transform Infrared Spectroscopy (FTIR), X-ray Fluorescence Spectrometry (FRX), pH, setting, radiopacity, compressive strength, cytotoxicity and bioactivity. The data obtained were statistically evaluated by the test of variance (ANOVA) with Bonferroni correction (p<0.05%). The pH test result: Niobium 10% Immediate (12.205 ±0.304); 24h; (12.770 ± 0.226) 48h: (12.910 ± 0.169). Niobium 20%: immediate (12.080 ± 0.282); 24h: (12.350 ± 0.593); 48 h: (12.580 ± 0.73). For initial setting time in seconds: MTA (397,500 ±10,606); Niobium 10% (294,333 + 90,897) and Niobium 20% (279,000 + 15,874). The final setting time for the groups were: MTA (15,000 + 49,497), Niobium 10% (560 ± 38,587), being smaller when compared to MTA (p<0,001) and Niobium 20% (715,666 ± 30,664) (p<0 .01). Radiopacity values in mm Al of 10% Niobium (3.888 ±0.340); Niobium 20% (3.713 ± 0.712). The compressive strength in MPa was: Niobium 10% (694.150 + 78.951) Niobium 20% (699.295 + 47.672). Cell viability showed no difference between MTA and experimental groups (p<0.05). The results of the osteogenesis capacity of the formulations from the alkaline phosphatase assay (ALF) in IU/L per gram of protein for each group were: MTA (1.9 + 1.227) and Niobium 20% (1.784 + 1.342) (p> 0.05). Our findings point to relevant properties for Nb2O5 formulations such as alkaline pH, radiopacity, compressive strength and alkaline phosphatase activity (AU).


Assuntos
Materiais Biocompatíveis , Cimentos Dentários , Endodontia , Nióbio , Espectrometria de Fluorescência/instrumentação , Microscopia Eletrônica de Varredura , Análise de Variância , Espectroscopia de Infravermelho com Transformada de Fourier , Materiais Dentários , Análise de Fourier
7.
J. res. dent ; 10(1): 1-8, jan.-mar2022. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1378176

RESUMO

This study aimed to evaluate if 2.5% sodium hypochlorite compromises the adhesion of bonding materials. The factors in the study were the irrigation solutions in two levels: 2.5% sodium hypochlorite and saline solution; and the adhesive systems used in three levels: three-step adhesive, universal adhesive, and two-step self-etch adhesive systems. The answer variable used was the microshear bond strength obtained through a universal testing machine and fracture mode. Six groups were obtained (n=10) : Etch-and-rinse/Saline (saline solution + 3-step adhesive system - Scotchbond Multipurpose, 3M ESPE); Universal/saline (saline solution + universal adhesive system ­ Prime&Bond,); Self-etch/saline (saline solution + 2-step self-etch adhesive systems - Clearfil SE Bond); Etch-and-rinse/Hypo (sodium hypochlorite 2,5% + 3-step adhesive system - Scotchbond Multiuso); Universal/Hypo (sodium hypochlorite 2,5% + universal adhesive system ­ Prime&Bond); Self-etch/Hypo (sodium hypochlorite 2,5% + 2-step self-etch adhesive system - Clearfil Se Bond). The specimens were obtained from 60 healthy bovine incisors. The crowns were separated from the roots, and the regularization of the buccal surface was performed. The groups received saline solution and 2.5% sodium hypochlorite for 30 minutes, respectively. A matrix of 1mm and 3mm oh height was stabilized by Scotch tape to obtain the resin sticks. Afterward, the bond strength test was performed in a universal testing machine at 1mm/min speed. The data were analyzed with normality Shapiro-Wilk, two-way ANOVA, and Tukey's tests (p<0.001). Etch-and-rinse and Self-etch adhesives presented the highest bond strength values after irrigation with saline solution and 2.5% sodium hypochlorite, respectively (P < 0.01). The irrigation with 2.5% sodium hypochlorite decreased the bond strength values of Etch-and-rinse and Universal (P < 0.01). On the other hand, 2.5% sodium hypochlorite improved the bond strength values of Self-etch (P < 0.01). In conclusion, 2.5% sodium hypochlorite negatively impacted the bond strength of Etch-and-rinse and Universal but improved the adhesion of Self-etch.


Assuntos
Animais , Bovinos , Hipoclorito de Sódio/administração & dosagem , Adesivos/química , Desinfecção , Colagem Dentária/métodos , Cimentos Dentários/uso terapêutico , Hipoclorito de Sódio/uso terapêutico , Solução Salina/administração & dosagem
8.
Belo Horizonte; s.n; 2022. 53 p. ilus.
Tese em Português | BBO - Odontologia | ID: biblio-1414645

RESUMO

As melhorias alcançadas nas propriedades físico-químicas dos materiais endodônticos permitiram a utilização de materiais de reparo em situações clínicas que eram consideradas críticas. Os chamados biocerâmicos, derivados do MTA, apresentando boa biocompatibilidade e bioatividade, se tornaram uma solução eficaz. Estes materiais apresentam propriedades clínicas melhoradas, com excelente consistência e manuseabilidade, além de adequado tempo de trabalho e presa. Estes cimentos seguem em evolução e as empresas vêm investindo em melhorias em suas composições com o intuito de potencializar suas propriedades biotivas. Este trabalho teve como objetivo avaliar o cimento biocerâmico Bio-C Repair (Angelus, Londrina, Paraná, Brasil) e o seu potencial sucessor, o cimento Bio-C Repair Íon+ (Angelus, Londrina, Paraná, Brasil), bem como o MTA (Angelus, Londrina, Paraná, Brasil). Foi aprovado pelo Comitê de Ética no Uso de Animal (CEUA-UFMG 350/2019). Tais biocerâmicos foram avaliados quanto às respostas de macrófagos. Os experimentos foram realizados no laboratório de Gnotobiologia e Imunologia do Instituto de Ciências Biológicas (ICB) da Universidade Federal de Minas Gerais. Utilizou-se macrófagos murinos obtidos de camundongos C57BL/6 quando se avaliou a viabilidade celular (pelo método MTT), a aderência celular, a capacidade de fagocitose (na presença da levedura S. boulardii) e a detecção da produção de Espécies Reativas de Oxigênio (ROS), na ausência e na presença de Zymosan A (de Saccharomyces cerevisiae), bem como, na presença e na ausência dos cimentos. Os macrófagos inflamatórios foram obtidos do peritônio dos animais após a injeção de caldo Tioglicolato estéril a 3%. Após aspirados, os macrófagos foram centrifugados e a concentração celular final foi ajustada de acordo com cada ensaio proposto: viabilidade e aderência (1x106 cel/mL); ensaio de fagocitose e ROS (5x105 cel/mL). Fez-se a manipulação dos materiais sob fluxo laminar, quando foram inseridos em capilares estéreis. Os resultados de viabilidade celular demonstraram que houve diferença significativa na cultura de 24 horas, tratada com o Bio-C Repair Íon+, em relação ao grupo controle. Os ensaios de fagocitose e aderência celular não apresentaram diferença estatisticamente significante entre os grupos. As análises demonstraram expressivos níveis de ROS quando as células foram tratadas na presença de Zymozan A. Na presença desse estímulo, o Bio-C Repair Íon+ apresentou diferença significativa em relação a todos os demais biocerâmicos e ao grupo controle. Os resultados foram analisados pelo teste ANOVA (P<0,05), comparando-se os grupos experimentais entre si e o grupo controle. Conclui-se que o novo material reparador Bio-C Repair Íon+ apresenta ações de biocompatibilidade quase semelhantes ao Bio-C Repair e MTA. As diferenças observadas em relação ao Bio-C Repair Ion+ quanto à viabilidade celular e a produção de ROS podem estar relacionadas ao íon metálico presente em sua composição.


The improvements achieved in the physicochemical properties of endodontic materials allowed the use of repair materials in clinical situations considered critical. The so-called bioceramics, derived from MTA, showing good biocompatibility and bioactivity, have become an effective solution. These materials have improved clinical properties, exhibiting excellent consistency and handling, as well as good working and setting time. These types of cement are still evolving, and companies have been investing in improvements in their compositions to enhance their bioactive properties. This study aimed to evaluate the Bio-C Repair bioceramic cement (Angelus, Londrina, Paraná, Brazil) and its potential successor, the Bio-C Repair Íon+ (Angelus, Londrina, Paraná, Brazil), as well as the MTA (Angelus, Londrina, Paraná, Brazil). The Animal Use Ethics Committee (CEUA) of the Federal University of Minas Gerais (UFMG) approved the study (350/2019). Such bioceramics were evaluated in macrophage responses. The experiments were carried out in the Gnotobiology and Immunology laboratory of the Institute of Biological Sciences (ICB) of the UFMG. Murine macrophages obtained from C57BL/6 mice were used to evaluate cell viability (by the MTT method), cell adhesion, phagocytosis capacity (in the presence of the yeast S. boulardii), and in the detection of the production of Reactive Oxygen Species (ROS) in the absence and presence of Zymosan A (from Saccharomyces cerevisiae), as well as in the presence and absence of types of cement. Inflammatory macrophages were obtained by injecting sterile 3% thioglycolate broth into the animals' peritoneum. After aspirating, the macrophages were centrifuged, and the final cell concentration was adjusted according to each proposed assay: viability and adherence (1x106 cells/mL), phagocytosis, and ROS assay (5x105 cells/mL). The materials were manipulated under laminar flow when inserted into sterile capillaries. The cell viability results showed a significant difference in the 24-hour culture, treated with Bio-C Repair Ion+, to the control group. The phagocytosis and cell adhesion assays showed no statistically significant difference between the groups. The analyses showed expressive ROS levels when the cells were treated in the presence of Zymosan A. In the presence of this stimulus, the Bio-C Repair Ion+ showed a significant difference between all other bioceramics and the control group. The results were analyzed by the ANOVA test (P<0.05), comparing the experimental groups and the control group. It is concluded that the new repair material Bio-C Repair Ion+ has biocompatibility actions almost similar to Bio-C Repair and MTA. The differences observed with Bio-C Repair Ion+ regarding cell viability and ROS production may be related to the metallic ion's composition.


Assuntos
Materiais Biocompatíveis , Teste de Materiais , Cimentos Dentários , Endodontia , Macrófagos
9.
Belo Horizonte; s.n; 2022. 97 p. ilus.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1428871

RESUMO

A cimentação de pinos de fibra de vidro à dentina intrarradicular, principalmente no terço apical, continua sendo um desafio na odontologia. O objetivo desse estudo foi avaliar a influência do controle de umidade com etanol na resistência de união de pinos de fibra de vidro em diferentes terços de dentina intrarradicular, 24 horas e 6 meses após o processo de cimentação adesiva. Sessenta e quatro incisivos bovinos extraídos foram submetidos ao tratamento endodôntico e divididos em dois grupos, de acordo com o tipo de controle de umidade (técnica convencional e alcoólica). Cada grupo foi dividido em 4 subgrupos (n=8) de acordo com a cimentação: RXU: Single bond Universal + RelyX Ultimate; PNV: primer de dentes Panavia V5 + Panavia V5; U200: RelyX U200; SET: Set PP. A resistência de união do pushout foi medida em diferentes áreas da interface entre o pino e a superfície radicular, 24 horas e 6 meses após o procedimento de união. Os dados foram submetidos ao teste de Bonferroni (α = 0,05). Os menores valores de resistência de união foram encontrados para o grupo SET, com diferença estatisticamente significante entre os demais grupos para os terços cervical e médio. Os maiores valores de resistência de união foram encontrados para o grupo PNV com diferença estatisticamente significante para os demais grupos nos terços médio e apical em 24 horas. Avaliando os diferentes terços, em geral, os maiores valores de resistência de união foram encontrados para o terço cervical. O grupo PNV apresentou maiores valores de resistência de união para os terços cervical e médio, sem diferença estatisticamente significante entre eles. Quanto ao tipo de controle de umidade, pode-se observar que não há diferença estatisticamente significativa para o grupo PNV às 24 horas, U200 e SET aos 6 meses. Na comparação entre os tempos (24 horas e 6 meses), em geral, os valores de resistência de união diminuíram após o armazenamento. Diferenças significativas com menores valores foram observadas após o tempo de seis meses nos valores de envelhecimento para a resistência de união. Por meio de um microscópio óptico e um aparelho de microscopia eletrônica de varredura o padrão de fratura na interface adesiva foi caracterizado.


Cementation of fiberglass posts to intraradical dentin, especially in the apical third, remains a challenge in dentistry. The study was to evaluate the influence of moisture control with ethanol on the bond strength of fiberglass posts in different thirds of intraradicular dentin, 24 hours and 6 months after the adhesive cementation process. Sixty-four extracted bovine incisors were endodontically protected and divided into two groups, according to the type of moisture control (conventional and alcoholic technique). Each group was divided into 4 subgroups (n=8) according to cementation: RXU: Single bond Universal + RelyX Ultimate; PNV: Panavia V5 tooth primer + Panavia V5; U200: RelyX U200; SET: Set PP. The pushout bond strength was measured in different areas of the interface between the post and the root surface, 24 hours and 6 months after the bonding procedure. The data were confirmed by the Bonferroni test (α = 0.05). The lowest bond strength values were found for the SET group, with a statistically significant difference between the other groups for the cervical and middle thirds. The highest bond strength values were found for the PNV group, with a statistically significant difference for the other groups in the middle and apical thirds at 24 hours. Evaluating the different thirds, in general, the highest bond strength values were found for the cervical third. The PNV group showed higher bond strength values for the cervical and middle thirds, with no statistically significant difference between them. As for the type of humidity control, it can be observed that there is no statistically significant difference for the PNV group at 24 hours, U200 and SET at 6 months. In the comparison between times (24 hours and 6 months), in general, the bond strength values decreased after storage. Minor elevation differences with values were observed after the six-month time in the ageing values for bond strength. Using an optical microscope and a scanning electron microscopy device, the fracture pattern at the adhesive interface was characterized.


Assuntos
Adesivos Dentinários , Cimentos Dentários , Pinos Dentários , Dentina
10.
Braz. dent. sci ; 25(1): 1-11, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1352726

RESUMO

Objective: To evaluate the influence of immediate dentin sealing (IDS) and mechanical methods for removing the temporary cement on the bond strength between dentin and resin cements. Material and Methods: Bovine incisors were ground until dentin exposure and divided according to two factors: "dentin surface treatment"' - cleaning with manual dental excavator (DE), with Robinson bristle brush and pumice paste (PP) or IDS application with Single Bond 2 (IDS/SB+PP) or Single Bond Universal (IDS/SBU+PP) plus cleaning with PP; and "resin cement" - Self-adhesive (RelyX U200) or conventional cement with self-etching adhesive (Multilink Automix). Simulating provisional restoration, acrylic resin plates were cemented onto the dentin surface (with or without IDS) with a non-eugenol temporary cement, and stored in distilled water (37 ºC; 7 days). The acrylic plates were removed, the dentin surface was cleaned (PP or DE), and starch tubes were positioned on the dentin where the resin cements were applied. After 24 h, the specimens were submitted to a microshear test (wire-loop method). Results: Two-way analysis of variance showed statistically significant influence of dentine surface treatments (p< 0.001) and resin cement (p= 0.001) in the bond strength values. The IDS/SBU+PP/U200 (7.24 MPa) and IDS/SBU+PP/MULTI (6.40 MPa) groups presented higher values when compared to cleaning with DE (DE/U200= 4.60 MPa; DE/MULTI= 1.45 MPa) and PP (PP/U200= 3.74 MPa; PP/MULTI= 3.14 MPa). Statistical difference was also found between the cements when dental excavator treatment was used (RelyX U200 ˃ Multilink Automix). The IDS/SBU+PP protocol presented a higher percentage of cohesive failures. The micrographs showed differences in dentin surface characteristics among the groups. Conclusion: Immediate dentin sealing increased the bond strength of the resin cements to dentin compared to mechanical cleaning only, regardless the resin cement. (AU)


Objetivo: Avaliar a influência do selamento dentinário imediato (IDS) e dos métodos mecânicos de remoção do cimento provisório na resistência de união entre dentina e cimentos resinosos. Materiais e Métodos: Incisivos bovinos foram desgastados até a exposição da dentina e divididos de acordo com dois fatores: "tratamento da superfície dentinária" - limpeza com cureta dentária manual (DE), com escova de cerdas Robinson e pasta de pedra-pomes (PP) ou aplicação de IDS com Single Bond 2 (IDS/SB +PP) ou Single Bond Universal (IDS/SBU+PP) mais limpeza com PP; e "cimento resinoso" - autoadesivo (RelyX U200) ou cimento convencional com adesivo autocondicionante (Multilink Automix). Simulando a restauração provisória, placas de resina acrílica foram cimentadas na superfície dentinária (com ou sem IDS) com um cimento provisório sem eugenol e armazenadas em água destilada (37 ºC; 7 dias). As placas de acrílico foram removidas, a superfície dentinária foi limpa (PP ou DE) e tubos de amido foram posicionados na dentina onde os cimentos resinosos foram aplicados. Após 24 h, os corpos-de-prova foram submetidos ao ensaio de microcisalhamento (método wire-loop). Resultados: A análise de variância de dois fatores mostrou influência estatisticamente significativa dos tratamentos de superfície dentinária (p< 0,001) e cimento resinoso (p= 0,001) nos valores de resistência de união. Os grupos IDS/SBU+PP/U200 (7,24 MPa) e IDS/SBU+PP/MULTI (6,40 MPa) apresentaram valores maiores quando comparados à limpeza com DE (DE/U200= 4,60 MPa; DE/MULTI= 1,45 MPa) e PP (PP/U200= 3,74 MPa; PP/MULTI= 3,14 MPa). Uma diferença estatística também foi encontrada entre os cimentos quando o tratamento com cureta dentária foi usado (RelyX U200 ˃ Multilink Automix). O protocolo IDS/SBU+PP apresentou maior percentual de falhas coesivas. As micrografias mostraram diferenças nas características da superfície dentinária entre os grupos. Conclusão: O selamento dentinário imediato aumentou a resistência de união dos cimentos resinosos à dentina em comparação com a limpeza mecânica apenas, independentemente do cimento resinoso.(AU)


Assuntos
Bovinos , Cimentos de Resina , Cimentos Dentários , Dentina
11.
Braz. dent. sci ; 25(1): 1-9, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1354535

RESUMO

Objective: This study aimed to determine the push-out-bond-strength(PBS) of mineral trioxide aggregate (BIOMTA+) and calcium-enriched-mixture-cement (CEM) in retrograde cavities prepared using Er: YAG laser and stainless-steel bur. Material and Methods: The root canals of 60 extracted single-rooted human teeth were prepared, filled and their apical portion of 3-mm were resected using a diamond bur and randomly divided into four groups according to technique of retrograde preparation and filling material as follows(n=15): Group1: bur/ BIOMTA+ ,Group2: bur/ CEM, Group3: Er:YAG laser/ BIOMTA+, Group4: Er:YAG laser/ CEM. PBS test were performed to specimens and failure modes were evaluated. The data were statistically analyzed with ANOVA, Post-Hoc Tukey and t tests (p< 0.05). Results: CEM was exhibited higher than bond strength compared to BIOMTA+ in retrograde cavity prepared using laser (p= 0.021) and BIOMTA+ in retrograde cavity prepared using bur was exhibited higher than bond strength compared to in retrograde cavities prepared using laser (p= 0.024). Failure modes were dominantly cohesive in all groups tested and one representative specimen each failure mode was examined in SEM and the general characteristics of the failure modes were confirmed. Conclusion: With in the limitations of the present study, when used CEM, Er: YAG laser-assisted retrograde cavity preparation positively affected the bond strength values compared to BIO MTA+. Considering its optimal adhesion, the calcium-enriched-mixture-cement (CEM) might be a good option as a filling material in retrograde cavities in clinical use. (AU)


Objetivo: O objetivo deste estudo foi determinar a força de união (PBS) de cimento de agregado trióxido mineral (BIO MTA+) e cimento enriquecido com cálcio (CEM) em preparos cavitários retrógrados realizados com: Laser Er-YAG e brocas de aço inoxidável. Material e Métodos: Canais radiculares de 60 dentes unirradiculares extraídos foram preparados, preenchidos e 3 mm de suas porções apicais foram ressecadas usando uma broca diamantada e divididos randomicamente em quatro grupos de acordo com a técnica de preparação retrógrada e o material de preenchimento (n=15): Grupo 1: Broca/BIO MTA+, Grupo 2: Broca/CEM, Grupo 3: Laser Er-YAG/BIO MTA+, Grupo 4: Laser Er-YAG/CEM. O teste de PBS foi realizado para as amostras e os modelos de falha foram avaliados. Os dados foram analisados estatisticamente pelos testes de ANOVA, Post-Hoc Tukey e testes t (p< 0.05). Resultados: CEM apresentou maior força de união que BIO MTA+ em cavidades retrógradas preparadas com laser (p= 0.021) e BIO MTA+ em cavidades retrógradas preparadas com brocas apresentou maior força de união quando comparado à cavidades retrógradas preparadas com laser (p= 0.024). Os modelos de falha foram predominantemente coesos em todos os grupos testados e um espécime representativo de cada modelo de falha foi examinado em MEV e as características gerais dos modelos de falha foram confirmadas. Conclusão: Com as limitações do presente estudo, quando usou-se CEM, o preparo de cavidades retrógradas através de Laser Er-YAG afetou positivamente os valores da força de união quando comparados com BIO MTA+. Considerando sua ótima adesão, o cimento enriquecido com cálcio (CEM) pode ser uma boa opção como um material de preenchimento em cavidades retrógradas no uso clínico.


Assuntos
Cimentos Dentários , Cavidade Pulpar , Lasers de Estado Sólido
12.
Pesqui. bras. odontopediatria clín. integr ; 22: e210044, 2022. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1365224

RESUMO

ABSTRACT Objective To assess the effects of coloring beverages on the color stability of two types of hybrid ceramics with different surface treatments. Material and Methods 180 specimens of two hybrid ceramics (Vita Enamic and Mazic Duro) and a feldspathic ceramic (Vita Mark II) were prepared (n=60 in each group). Half of the discs in each group were glazed while the other was polished. The specimens were then divided into three subgroups and immersed in distilled water, carrot juice, and coffee. The overall color difference (∆E) was calculated based on CIE L*a*b* color space. Data were analyzed using three-way and one-way ANOVA; Tukey's honest significant difference was also done for pairwise comparisons (α=0.05). Results Vita Mark II specimens revealed less overall color changes compared to other groups. The ∆E of the glazed Vita Enamic specimens was greater than polished specimens following immersion in distilled water (p=0.03) and coffee (p=0.001), but it was not significant for carrot juice. The same results were obtained for polished Mazic Duro specimens. Relatively similar amounts of ∆E were recorded in polished and glazed subgroups of Vita Mark II. Conclusion The ∆E of hybrid ceramics was higher than Vita Mark II. Polishing could be recommended for surface treatment of hybrid ceramics instead of glazing, saving time and facilitating the process.


Assuntos
Espectrofotometria/instrumentação , Propriedades de Superfície , Bebidas , Cor , Cimentos Dentários , Água Destilada , Cerâmica , Análise de Variância , Prótese Dentária , Desenho Assistido por Computador/instrumentação , Café , Porcelana Dentária , Corantes , Sucos de Frutas e Vegetais , Irã (Geográfico)/epidemiologia
13.
Pesqui. bras. odontopediatria clín. integr ; 22: e210058, 2022. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1365226

RESUMO

ABSTRACT Objective To evaluate and compare the effect of 17% Ethylenediaminetetraacetic Acid (EDTA), 9% Etidronic acid (HEDP), and 7% Maleic acid (MA) on the push-out bond strength of NeoMTA Plus sealer to the coronal, middle, and apical thirds of root canal dentin. Material and Methods Forty single-rooted human maxillary central incisors were selected and decoronated to 12 mm long root fragments. Working length was established and root canals were then enlarged up to rotary Protaper F3. After each instrumentation, the root canal was irrigated with 2.5% NaOCl. For the final irrigation regimen, the specimens were divided into 4 groups (n=10) and treated with EDTA, HEDP, MA or Saline. Root canals were coated with NeoMTA Plus sealer, and obturation was done with single cone obturation technique. Subsequently, three horizontal sections were taken from the coronal, middle and apical thirds of each specimen, and POBS was measured using a universal testing machine. The type of bond failures was assessed under a stereomicroscope. Statistical analysis was done with One-way ANOVA with Tukey's Post hoc analysis. Results MA and EDTA showed the highest POBS. There was no significant difference in bond strength between MA and EDTA (p>0.05). HEDP and Saline showed lower POBS. Among all the four groups, the coronal third showed the highest values, followed by middle and apical thirds. Conclusion The type of chelating agent used during the root canal treatment significantly affects the bond strength of NeoMTA Plus to the root canal dentin.


Assuntos
Humanos , Materiais Restauradores do Canal Radicular , Resistência à Tração , Quelantes/química , Cimentos Dentários , Endodontia , Análise de Variância , Ácido Edético , Ácido Etidrônico , Materiais Dentários/química , Incisivo , Índia , Hidrazida Maleica
14.
Pesqui. bras. odontopediatria clín. integr ; 22: e210114, 2022. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1365227

RESUMO

ABSTRACT Objective To compare the cytotoxicity of commercial reparative endodontic cements on human periodontal ligament stem cells (hPDLSCs). Material and Methods The culture of hPDLSCs was established. Cell density was set at 2 × 104 cells/well in 96-well plates. Extracts of Biodentine, Bio-C Repair, Cimmo HD, MTA Repair HP and White MTA were prepared. Then, the extracts were diluted (pure, 1:4 and 1:16) and inserted into cell-seeded wells for 24, 48, and 72 h to assess cell viability through MTT assay. hPDLSCs incubated with culture medium alone served as a negative control group. Data were analyzed by Two-Way ANOVA and Tukey's test (α=0.05). Results At 24 h, pure extract of MTA Repair HP and Biodentine 1:16 presented higher cell viability compared to control. Lower cell viability was found for pure extract of Cimmo HD, MTA Repair HP 1:4 and 1:16, and White MTA 1:16. At 48 h, pure extract of Bio-C Repair and MTA Repair HP presented higher cell viability compared to control. At 72 h, only the pure extract of MTA Repair HP led to higher cell proliferation compared to control. Conclusion Biodentine, Bio-C Repair and MTA Repair HP were able to induce hPDLSCs proliferation. Cimmo HD and White MTA were found to be mostly cytotoxic in hPDLSCs.


Assuntos
Ligamento Periodontal/anatomia & histologia , Materiais Restauradores do Canal Radicular , Células-Tronco/imunologia , Testes Imunológicos de Citotoxicidade/instrumentação , Cimentos Dentários , Testes Imunológicos/instrumentação , Brasil , Contagem de Células , Análise de Variância , Endodontia , Cultura Primária de Células
15.
Braz. dent. sci ; 25(1): 1-9, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1361885

RESUMO

Objetivo: O objetivo foi avaliar a resistência de união de seis adesivos experimentais contendo sistemas fotoiniciadores binários ou ternários, associados a três diferentes concentrações de MDP (0-12% em peso) após 12 meses de armazenamento em água destilada. Material e Métodos: Adesivos experimentais foram preparados com: bis-GMA, UDMA, bis-EMA, TEGDMA, HEMA, BHT e etanol, contendo sistemas fotoiniciadores binários (CQ/amina) ou ternários (CQ/amina/DPIHFP ­ 0,5% em peso). Foi adicionado a esta composição 0%, 6% ou 12% em peso de MDP. Os sistemas adesivos foram aplicados seguindo o protocolo com condicionamento ácido. Moldes cilíndricos transparentes foram colocados sobre a dentina hibridizada, preenchidos com resina composta e fotopolimerizados. Os corpos-de-prova foram armazenados em água destilada a 37oC por 24h ou 12 meses e submetidos ao ensaio de microcisalhamento (n=6). Os dados foram analisados por ANOVA de três fatores e teste de Tukey (α=5%). Resultados: Para o sistema binário, após 12 meses de armazenamento, todos os valores de resistência de união foram semelhantes. Em relação à degradação da resistência de adesão ao longo do tempo, as formulações de MDP de 6% e 12% mostraram resistência de união mais estável do que 0% de MDP. Para o sistema ternário, todas as formulações (0%, 6% e 12% em massa de MDP) mostraram resistência de união estável em função do tempo. Conclusão: Para o sistema binário, as concentrações de 6 e 12% em massa de MDP foram capazes de manter a resistência de união em função do tempo, enquanto que para o sistema ternário, a estabilidade de união foi obtida independentemente da concentração de MDP. Pode-se concluir que, para a formulação dos adesivos utilizados neste estudo, independente do sistema fotoiniciador, a concentração de 12% MDP apresentou valores de resistência de união mais estáveis após 12 meses de armazenamento em água (AU)


Objective: The aim was to evaluate the bond strength of six experimental adhesives containing binary or ternary photoinitiator systems, associated with three different MDP concentrations (0-12wt%) after 12 months of storage in distilled water. Material and Methods: Experimental adhesives were prepared with: bis-GMA, UDMA, bis-EMA, TEGDMA, HEMA, BHT, and ethanol, containing binary (CQ/amine) or ternary (CQ/amine/DPIHFP (diphenyliodonium hexafluorophosphate) ­ 0.5wt%) photoinitiator systems. It was added to this composition 0wt%, 6wt%, or 12wt% of MDP. The adhesive systems were applied following the etch-and-rinse protocol. Transparent cylindrical molds were placed on the hybridized dentin, filled with composite resin and light-cured. The specimens were stored in distilled water at 37oC for 24h or 12 months and submitted to a microshear bond strength test (n=6). Data were analyzed by three-way ANOVA and Tukey's test (α=5%). Results: For the binary system, after 12 months of storage, all bond strength values were similar. Regarding bond strength degradation over time, 6wt% and 12wt% MDP formulations showed more stable bond strength than 0wt% MDP. For the ternary system, all formulations (0wt%, 6wt% and 12wt%) showed stable bond strength over time. Conclusion: For the binary photoinitiator system, the 6wt% and 12wt% MDP concentrations were able to keep bond strength stable over time, while for the ternary system, bond strength stability was achieved regardless the MDP concentration. (AU)


Assuntos
Cimentos Dentários , Fotoiniciadores Dentários
16.
Braz. dent. sci ; 25(2): 1-6, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1363727

RESUMO

Objective: The aim of this study was to evaluate the effects of material and processing methods on the bond strength of orthodontic brackets. Material and Methods: Five types of brackets were tested: Conventional metallic (CM), metallic sandblasted (SB), ceramic (C), polycarbonate (PC), and metallic fabricated by melting injection molding (MIM). Shear bond strength (SBS) was conducted to check bond strength of the brackets bonded to bovine teeth (n=10/group), and tensile bond strength (TBS) (20 brackets/group) to check bracket retention to bonding material (n=20/group). Both, SBS and TBS were conducted with 1mm/min crosshead speed in a universal testing machine. Bond strength was calculated in Megapascal (MPa) based on force (N) and bracket area (mm 2). Data normality was verified, and One-way ANOVA was the statistical test with Tukey post-hoc (α=0.05). Results: SB and MIM presented higher SBS compared to C, PC, and CM (p<0.05). SB and MIM also presented significantly higher TBS compared to CM and PC (p<0.05). However, MIM was not different of C for TBS. Conclusion: The type of material and method of fabrication are determinant factors that affect bond strength of orthodontic brackets and melting injection molding (MIM) is a remarkable technology to improve brackets retention during the orthodontic treatment. (AU)


Objetivo: O objetivo deste estudo foi avaliar os efeitos dos materiais e métodos de processamento na resistência de união de bráquetes ortodônticos. Material e Métodos: Cinco tipos de bráquetes foram testados: Convencionais metálicos (CM), metálicos jateados (SB), cerâmico (C), policarbonato (PC), e metálico fabricado por injeção de metal fundido em molde (MIM). A resistência de união ao cisalhamento (SBS) foi conduzida para verificar a resistência de união dos bráquetes aderidos a dentes bonivos (n=10/grupo) e a resistência à tração (TBS) (20 bráquetes/grupo) para verificar a retenção do bráquete ao material adesivo (n=20/grupo). SBS e TBS foram conduzidas com relação carga/velocidade de 1mm/min em uma máquina de ensaios universal. A resistência de união foi calculada em Megapascal (MPa) com base na força (N) pela área do bráquete (mm 2). A normalidade dos dados e a estatística foi realizada utilizando One-way ANOVA e Tukey post-hoc (α=0.05). SB e MIM apresentaram os maiores valores de SBS comparados com C, PC e CM (p<0.05). Resultados: SB e MIM também apresentaram valores significativamente maiores de TBS comparados com CM e PC (p<0.05). Contudo, os valores de TBS para o grupo MIM não foram significativamente diferentes de C. Conclusão: O tipo de material e o método de fabricação são fatores determinantes que afetam a resistência de união de bráquetes ortodônticos e a injeção de metal fundido em molde (MIM) é uma tecnologia relevante para melhorar a retenção dos bráquetes durante o tratamento ortodôntico. (AU)


Assuntos
Animais , Bovinos , Braquetes Ortodônticos , Cimentos Dentários , Resistência ao Cisalhamento
17.
Araçatuba; s.n; 2022. 125 p. ilus, tab.
Tese em Inglês, Português | LILACS, BBO - Odontologia | ID: biblio-1444801

RESUMO

O objetivo desse estudo de revisões sistemáticas e meta-análises foi responder se os cimentos biocerâmicos resultam melhores efeitos para a dor pós operatória, capacidade em penetração em túbulos dentinários e atividade antimicrobiana em comparação ao cimento AH Plus®. Foram conduzidas duas revisões sistemáticas, orientadas pelas diretrizes PRISMA e foram registradas na PROSPERO (CRD4202125928) (Capítulo 1) e na Open Science Framework (OSF) Registries (https://doi.org/10.17605/OSF.IO/BX7VQ) (Capítulo 2). Uma pergunta foi feita com base na população, intervenção, comparação e resultado (PICO), Capítulo 1: "O uso dos cimentos biocerâmicos resulta em menos dor pós operatória em comparação ao uso do cimento AH Plus® em pacientes tratados endodonticamente?"; Capítulo 2: "Os cimentos obturadores biocerâmicos apresentam superioridade na penetração em túbulos dentinários e atividade antimicrobiana ao cimento obturador AH Plus®?". Foram definidas as estratégias de buscas e realizadas buscas nas bases de dados: PubMed, Scopus, Web of Science, Embase, Cochrane Library, e OpenGrey. O Capítulo 1 utilizou a escala Cochrane para avaliar o risco de viés e a ferramenta GRADE para avaliar a qualidade das evidências. Enquanto, o Capítulo 2 utilizou a escala The Joanna Briggs para avaliar o risco de viés de estudos in vitro. As metaanálises foram conduzidas usando o "Meta" package, version 3.6.3, a diferença média (MD) medida de efeito foi calculada para variáveis quantitativas e odds ratio (OR) (Capítulo 1) e diferenças de médias padronizadas (SMD) (Capítulo 2), com um intervalo de confiança (IC) de 95%. Os resultados do Capítulo 1, foram incluídos 13 artigos na revisão sistemática, 11 foram incluídos na meta-análise. Para as variáveis quantitativas, o cimento biocerâmico apresentou menor ocorrência de dor pós-operatória do que o cimento AH Plus® em 24h (MD - 0,4101 [-0,80; -0,02], p = 0,0386) e 48h (MD -0,31 [-0,59; -0,03], p = 0,0295). Para as variáveis binárias, não houve diferença observada entre os cimentos avaliados: 24h (OR 1,12 [0,69; 1,80] p = 0,6476), 48h (OR 1,56 [0,76; 3,20] p = 0,2267), 72h (OR 1,38 [0,55; 3,45] p = 0,4893) e 7 dias (OR 2,10 [0,55; 8,01], p = 0,2790). Em relação à análise de risco de viés, observou-se baixo risco para a maioria dos domínios, exceto alocação que foi considerada pouco clara, enquanto a certeza da evidência variou de moderada a baixa. Os resultados do Capítulo 2, foram um total de 54 estudos foram incluídos, e 16 estudos foram incluídos na meta-análise. De modo geral, os estudos apresentaram baixo risco de viés. Não foi observado diferença estatística entre os cimentos avaliados para penetração em túbulos dentinários, independentemente dos terços: coronal SMD 0.58 [0.14; 1.31], p = 0.12; médio SMD 0.07 [0.54; 0.39], p = 0.75; e apical: SMD 0.08 [0.73; 0.56], p = 0.80. Os cimentos biocerâmicos e AH Plus® demonstraram similar ação antimicrobiana SMD [3.42; 5.32], p = 0.67 e SMD 0.67 [1.89; 0.55], p = 0.2825. Dessa forma, conclui-se que os cimentos biocerâmicos apresentam menor dor pós operatória nas primeiras 24 e 48 horas, e apresentam respostas similares para penetração em túbulos dentinários e atividade antimicrobiana quando comparado ao cimento AH Plus®(AU)


The aim of this study of systematic reviews and meta-analyses was to answer whether bioceramic sealers have better effects on postoperative pain, ability to penetrate dentinal tubules and antimicrobial activity compared to AH Plus® sealer. Two systematic reviews, guided by PRISMA guidelines, were conducted and registered in PROSPERO (CRD4202125928) (Chapter 1) and Open Science Framework (OSF) Registries (https://doi.org/10.17605/OSF.IO/BX7VQ) (Chapter 2). A question was asked based on population, intervention, comparison and outcome (PICO), Chapter 1: "Does the use of bioceramic sealers result in less postoperative pain compared to the use of AH Plus® sealer in endodontically treated patients?"; Chapter 2: "Do bioceramic filling sealers have superior penetration into dentinal tubules and antimicrobial activity compared to AH Plus® filling sealer?". Search strategies were defined and searches performed in the following databases: PubMed, Scopus, Web of Science, Embase, Cochrane Library, and OpenGrey. Chapter 1 used the Cochrane scale to assess the risk of bias and the GRADE tool to assess the quality of evidence. Meanwhile, Chapter 2 used The Joanna Briggs scale to assess the risk of bias from in vitro studies. Meta-analyses were conducted using the "Meta" package, version 3.6.3, the mean difference (MD) effect measure was calculated for quantitative variables and odds ratio (OR) (Chapter 1) and standardized mean differences (SMD) (Chapter 2), with a 95% confidence interval (CI). The results of Chapter 1 were included 13 articles in the systematic review, 11 were included in the meta-analysis. For quantitative variables, the bioceramic sealer had a lower occurrence of postoperative pain than the AH Plus® sealer in 24 hours (MD - 0.4101 [-0.80; - 0.02], p = 0.0386) and 48h (MD -0.31 [-0.59; -0.03], p = 0.0295). For the binary variables, there was no difference observed between the sealers evaluated: 24h (OR 1.12 [0.69; 1.80] p = 0.6476), 48h (OR 1.56 [0.76; 3.20] p = 0.2267), 72h (OR 1.38 [0.55; 3.45] p = 0.4893) and 7 days (OR 2.10 [0.55; 8.01], p = 0 .2790). Regarding the risk of bias analysis, a low risk was observed for most domains, except for allocation that was considered unclear, while the certainty of evidence ranged from moderate to low. The results of Chapter 2 were a total of 54 studies included, and 16 studies were included in the meta-analysis. Overall, the studies had a low risk of bias. There was no statistical difference between the sealers evaluated for penetration into dentinal tubules, regardless of the thirds: coronal SMD 0.58 [0.14; 1.31], p = 0.12; average SMD 0.07 [0.54; 0.39], p = 0.75; and apical: SMD 0.08 [0.73; 0.56], p = 0.80. Bioceramic sealers and AH Plus® demonstrated similar antimicrobial action to SMD [3.42; 5.32], p = 0.67 and SMD 0.67 [1.89; 0.55], p = 0.2825. Thus, it is concluded that bioceramic sealers have less postoperative pain in the first 24 and 48 hours, and have similar responses for penetration into dentinal tubules and antimicrobial activity when compared to AH Plus® sealer(AU)


Assuntos
Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular , Cimentos Dentários , Anti-Infecciosos , Tratamento do Canal Radicular , Cerâmica , Calcarea Silicata , Resinas Epóxi
18.
São José dos Campos; s.n; 2022. 78 p. tab, ilus, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1397436

RESUMO

Este estudo, desenvolvido em duas etapas, avaliou a ação remineralizadora da biopartícula α-wollastonita (BP), a partir da reação com H3PO4 residual Si-O-Ca + H3PO4 → SiO2 + Ca5(PO4)3(OH)n + H2O, na resistência longitudinal de união e características da interface adesiva, quando aplicada na forma de suspensão (etanol 99,5% + 10% de BP em peso) na superfície dentinária previamente condicionada com H3PO4 37%. Na primeira etapa foi realizado um estudo piloto onde, pelas características de precipitação, foi identificada a melhor concentração de biopartículas a serem inseridas na formulação da suspensão. Na segunda etapa, duzentas coroas hígidas de incisivos bovinos foram embutidas em resina acrílica, polidas para padronizar a smear layer e divididas aleatoriamente em 2 grupos (n=100), segundo a estratégia adesiva: A - controle (H3PO4 + Single Bond™ Universal (SB)); WAS ­ (H3PO4 + BP em suspensão + SB). Blocos de resina composta (Filtek Z250; 3M/ESPE) de 4mm foram confeccionados por técnica incremental sobre as áreas tratadas em todos os grupos, utilizando uma matriz de silicona. As amostras foram então seccionadas para obtenção de palitos retangulares (aproximadamente 1mm2 ), armazenadas em água deionizada a 4ºC em recipientes individuais e divididas em 2 subgrupos (n=50) de acordo com o tempo de armazenamento de 24 h (imediato) e 12 meses (longitudinal), seguidos do teste de resistência adesiva à microtração (10 kgf, 0,5mm/min). Os dados foram submetidos ao teste ANOVA 2 fatores (p< 0,05) e teste de Weibull 2 parâmetros. As interfaces adesivas foram analisadas por microscopia eletrônica de varredura (MEV) para avaliar a morfologia da interface resina-dentina, e analisadas por espectroscopia FTIR, para compreensão das interações químicas formadas na superfície dentinária. Os Resultados evidenciaram maiores valores estatisticamente significativos de resistência de união (MPa) para o grupo WAS (37,39 ± 7,48), tratado com BP e armazenado por 24 h, em comparação ao grupo A armazenado por 24 h (27,58 ± 6,43); e, para o grupo WAS armazenado por 12 meses (32,05 ± 10,64) em comparação ao grupo A armazenado por 12 meses (22,84 ± 5,76). Dados do FTIR evidenciaram o efeito da α-wollastonita na preservação do colágeno. A biopartícula mostrou ser promissora na manutenção longitudinal da qualidade da interface adesiva. (AU)


This study, developed in two stages, evaluated the remineralizing action of the αwollastonite (BP) bioparticle, from the reaction with residual Si-O-Ca + H3PO4 → SiO2 + Ca5(PO4)3(OH)n + H2O, on the longitudinal bond strength and characteristics of the adhesive interface, when applied as a suspension (99.5% ethanol + 10% BP by weight) on the dentin surface previously etched with 37% H3PO4. In the first stage, a pilot study was carried out where, due to the precipitation characteristics, the best concentration of bioparticles to be inserted in the suspension formulation was identified. In the second step, two hundred sound bovine incisor crowns were embedded in acrylic resin, polished to standardize the smear layer and randomly divided into 2 groups (n=100), according to the adhesive strategy: A - control (H3PO4 + Single Bond™ Universal (SB)); WAS ­ (H3PO4 + BP in suspension + SB). Composite resin blocks (Filtek Z250; 3M/ESPE) of 4 mm were made by incremental technique on the treated areas in all groups, using a silicone matrix. The samples were then sectioned to obtain rectangular sticks (approximately 1mm2 ), stored in deionized water at 4ºC in individual containers and divided into 2 subgroups (n=50) according to the storage time of 24 h (immediate) and 12 months (longitudinal), followed by the microtensile bond strength test (10 kgf, 0.5 mm/min). Data were submitted to 2-way ANOVA (p<0.05) and 2-parameter Weibull test. The adhesive interfaces were analyzed by scanning electron microscopy (SEM) to evaluate the morphology of the resin-dentin interface, and analyzed by FTIR spectroscopy, to understand the chemical interactions formed on the dentin surface. The results showed higher statistically significant values of bond strength (MPa) for the WAS group (37.39 ± 7.48), treated with BP and stored for 24 h, compared to group A stored for 24 h (27, 58 ± 6.43); and for the WAS group stored for 12 months (32.05 ± 10.64) compared to group A stored for 12 months (22.84 ± 5.76). FTIR data evidenced the effect of α-wollastonite on collagen preservation. The bioparticle showed promise in the longitudinal maintenance of the quality of the adhesive interface (AU)


Assuntos
Animais , Bovinos , Resinas Acrílicas , Análise de Variância , Resinas Compostas , Cimentos Dentários , Técnicas In Vitro , Microscopia Eletrônica de Varredura , Colágeno
19.
Braz. j. oral sci ; 20: e210445, jan.-dez. 2021. ilus
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1253016

RESUMO

Aim. To evaluate the bond durability of two universal adhesives; mild and ultra-mild in both etch-and-rinse and self-etch modes after simulated in-vitro degradation by long-term water storage or thermocycling. Methods. A total of 144 specimens were used in this study; 120 specimens (prepared from 30 teeth) for microshear bond strength testing and fracture mode assessment, and 24 specimens for scanning electron microscopic evaluation (prepared from 24 teeth). Specimens were prepared from 54 recently extracted caries free third molars and randomly divided into 12 groups, according to the adhesive treatment (All Bond or Scotchbond Universal), etching mode (etch-andrinse or self-etch) and aging method (thermocycling or water storage). Each tooth was sectioned mesio-distally into two halves exposing free dentin surface for bonding where dentin substrate 1 mm below the dentino-enamel junction was used. After adhesive application and composite build up, specimens were tested in shear mode after storing in distilled water at 37˚C for 24 hours or 1 year, or after being thermocycled between 5 and 55 °C for 10,000 cycles (n=10). Microshear bond strength (µSBS) was tested using a universal testing machine. Adhesive-dentin interface was examined using scanning electron microscope (SEM) (n=2). Data were analyzed using 3 way AN0VA and pairwise comparisons was performed using Bonferroni correction at significance level of α ≤0.05. Results. Statistical analysis revealed non-significant difference for etching mode in both adhesives (p=0.596). After aging, the bond strength was only reduced in Scotchbond Universal after one year of water storage in both modes (p<0.001). SEM evaluation revealed intact hybrid layer and longer resin tags for etch-and-rinse mode than selfetch mode of both adhesives. Conclusion. The bond strength of universal adhesives is not affected by the etching mode, however its durability was shown to be material dependent


Assuntos
Colagem Dentária , Cimentos Dentários , Dentina
20.
Braz. dent. j ; 32(3): 21-31, May-June 2021. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1345507

RESUMO

Abstract This study assessed the fracture resistance of simulated immature teeth reinforced with calcium aluminate cement (CAC) or mineral trioxide aggregate (MTA) containing calcium carbonate nanoparticles (nano-CaCO3). The microstructural arrangement of the cements and their chemical constitution were also evaluated. Forty-eight canines simulating immature teeth were distributed into 6 groups (n=8): Negative control - no apical plug or root canal filling; CAC - apical plug with CAC; CAC/nano-CaCO3 - apical plug with CAC+5% nano-CaCO3; MTA - apical plug with MTA; MTA/nano-CaCO3 - apical plug with MTA+5% nano-CaCO3; and Positive control - root canal filling with MTA. The fracture resistance was evaluated in a universal testing machine. Samples of the cements were analyzed under Scanning Electron Microscope (SEM) to determine their microstructural arrangement. Chemical analysis of the cements was performed by Energy Dispersive X-ray Spectroscopy (EDS). The fracture resistance of CAC/nano-CaCO3 was significantly higher than the negative control (p<0.05). There was no significant difference among the other groups (p>0.05). Both cements had a more regular microstructure with the addition of nano-CaCO3. MTA samples had more calcium available in soluble forms than CAC. The addition of nano-CaCO3 to CAC increased the fracture resistance of teeth in comparison with the non-reinforced teeth. The microstructure of both cements containing nano-CaCO3 was similar, with a more homogeneous distribution of lamellar- and prismatic-shaped crystals. MTA had more calcium available in soluble forms than CAC.


Resumo Este estudo avaliou a resistência à fratura de dentes imaturos simulados reforçados com cimento de aluminato de cálcio (CAC) ou trióxido agregado mineral (MTA) contendo nanopartículas de carbonato de cálcio (nano-CaCO3). O arranjo microestrutural dos cimentos e sua constituição química também foram avaliados. Quarenta e oito caninos simulando dentes imaturos foram distribuídos em 6 grupos (n=8): Controle negativo - sem plug apical ou obturação do canal radicular; CAC - plug apical com CAC; CAC/nano-CaCO3 - plug apical com CAC + 5% nano-CaCO3; MTA - plug apical com MTA; MTA/nano-CaCO3 - plug apical com MTA + 5% nano-CaCO3; e Controle positivo - obturação dos canais radiculares com MTA. A resistência à fratura foi avaliada em máquina universal de ensaios. Amostras dos cimentos foram analisadas em Microscópio Eletrônico de Varredura (MEV) para determinar seu arranjo microestrutural. A análise química dos cimentos foi realizada por Espectroscopia de Energia Dispersiva de Raio-X (EDS). A resistência à fratura de CAC/nano-CaCO3 foi significativamente maior do que o controle negativo (p<0,05). Não houve diferença significativa entre os outros grupos (p>0,05). Ambos os cimentos apresentaram microestrutura mais regular com a adição de nano-CaCO3. As amostras de MTA apresentaram mais cálcio disponível em formas solúveis do que CAC. A adição de nano-CaCO3 ao CAC aumentou a resistência à fratura dos dentes em comparação aos dentes não reforçados. A microestrutura de ambos os cimentos contendo nano-CaCO3 foi semelhante, com uma distribuição mais homogênea de cristais de formato lamelar e prismático. MTA apresentou mais cálcio disponível nas formas solúveis do que CAC.


Assuntos
Humanos , Materiais Restauradores do Canal Radicular , Fraturas dos Dentes , Óxidos , Obturação do Canal Radicular , Silicatos , Compostos de Cálcio , Compostos de Alumínio , Ápice Dentário , Cimentos Dentários , Combinação de Medicamentos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...