Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 482
Filtrar
1.
Braz. j. oral sci ; 23: e243158, 2024. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1527026

RESUMO

Aim: In recent years, great advances have been made in the use of CAD/CAM to prepare fixed restorations. The marginal and internal fit of these restorations is a principal determinant for their clinical success. In addition, the nature of the oral environment affects the mechanical properties of these restorations. Therefore, this study aimed to investigate the effect of aging process under conditions that simulate the oral environment on the marginal adaptation, and, fracture resistance of crowns fabricated from polyether ether ketone (PEEK) using CAD/CAM methods. Methods: Twenty identical crown restorations were fabricated by using CAD/CAM methods to mill polyether ether ketone (PEEK) material. These crowns were produced by using a software design of an epoxy resin replica of the prepared maxillary first premolar tooth. All PEEK crowns were cemented and randomly divided into two equal groups (A, B). Each group was divided into subgroups (A1, A2 and B1, B2). Group A1 and A2 were used to measure marginal adaptation and fracture resistance, respectively, before aging, while group (B1 and B2) were measured after aging. The cemented crowns were mounted in resin molds to facilitate the sectioning process. The measurements of the marginal gap were performed after sectioning at four points using a stereomicroscope. The fracture resistance of the crowns was investigated using a universal testing machine. A statistical analysis was performed using the GraphPad Prism® software version and unpaired Student's t-test. Results: The results revealed that aging affected the marginal gap, and the fracture resistance of the PEEK crowns. While aging, negatively affected the conditions under investigation, however the least significant difference of marginal gap was found in the margin region. Conclusions: PEEK-CAD/CAM is considered as a good alternative prosthodontic material for fixed prostheses. The CAD/CAM technique used to make PEEK crown restorations in our study offers the advantages of high marginal accuracy and fracture resistance for long-term performance in the oral environment


Assuntos
Polímeros , Envelhecimento , Desenho Assistido por Computador , Adaptação Marginal Dentária , Coroas , Resistência à Flexão , Cetonas
2.
Rev. Odontol. Araçatuba (Impr.) ; 44(2): 24-29, maio-ago. 2023. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1428024

RESUMO

As próteses parciais removíveis (PPRs) são uma alternativa de tratamento viável na prática clínica para reabilitar arcos parcialmente desdentados. Entretanto, o planejamento dessas próteses e preparo bucal prévio são frequentemente negligenciados. O presente artigo tem como objetivo relatar o caso clínico de uma reabilitação oral com PPRs superior e inferior após abordagem multidisciplinar, de modo a enfatizar as fases de um planejamento criterioso e de preparo prévio dos dentes pilares, visando o sucesso e a longevidade da reabilitação. Paciente do sexo masculino de 57 anos de idade compareceu à clínica da Faculdade de Odontologia de Bauru, Universidade de São Paulo, queixando-se da estética de seu sorriso e de algumas ausências dentárias. O indivíduo utilizava uma PPR provisória inferior insatisfatória e apresentava perda de dimensão vertical de oclusão (DVO). Após o exame clínico, radiográfico e estudo do caso em articulador semi-ajustável, realizou-se o planejamento com abordagens restauradoras, endodônticas, periodontais e protéticas. Após tratamento periodontal, foi realizada endodontia dos elementos 12, 15 e 47, confecção de núcleos e coroas nos dentes 12 e 15, restauração a nível gengival para apoio residual no dente 47, restaurações nos dentes 11, 13, 22, 24 e 44 e, por fim, a confecção das PPRs superior e inferior. A abordagem multidisciplinar utilizada neste caso clínico viabilizou o restabelecimento da DVO e possibilitou o sucesso da reabilitação protética(AU)


Removable partial dentures (RPDs) are a viable treatment alternative in clinical practice to rehabilitate partially edentulous arches. However, the planning of these dentures and prior oral preparation are often neglected. This article aims to report the clinical case of an oral rehabilitation with upper and lower RPDs after a multidisciplinary approach, to emphasize the phases of careful planning and prior preparation of the abutment teeth, aiming at the success and longevity of the rehabilitation. A 57-year-old male patient came to the clinic of the Bauru School of Dentistry, University of São Paulo, complaining about the esthetics of his smile and some missing teeth. The subject was using an unsatisfactory lower provisional prosthesis and had a loss of vertical dimension of occlusion (OVD). After the clinical and radiographic examination and the case study in a semi-adjustable articulator, planning was carried out with restorative, endodontic, periodontal and prosthetic approaches. After periodontal treatment, endodontics were performed on elements 12, 15 and 47, creation of cores and crowns on teeth 12 and 15, restoration at the gingival level for residual support on tooth 47, restorations on teeth 11, 13, 22, 24 and 44 and, finally, the making of the upper and lower PPRs. The multidisciplinary approach used in this clinical case enabled the restoration of the OVD and enabled the success of the oral rehabilitation(AU)


Assuntos
Humanos , Masculino , Adulto , Dimensão Vertical , Arcada Edêntula/terapia , Planejamento de Prótese Dentária , Prótese Parcial Removível , Dentaduras , Arcada Edêntula , Coroas , Estética Dentária
3.
Rev. Odontol. Araçatuba (Impr.) ; 44(2): 53-59, maio-ago. 2023. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1428072

RESUMO

A estética tem um papel importante na aceitação e autoestima das pessoas e, em virtude disso, os pacientes buscam cada dia mais ter um sorriso harmonioso. As reabilitações estéticas devem envolver um planejamento completo, atrelando função e estética, avaliando tamanho dos dentes, perfil e alturas gengivais, altura do sorriso e corredor bucal. Por conta disso, a odontologia nos permite uma série de abordagens terapêuticas diferentes que chegam a resultados satisfatórios para o paciente. Sendo assim, o presente trabalho tem como objetivo descrever um relato de caso de uma paciente com queixa estética do seu sorriso devido à diferentes tonalidades, formas e tamanhos dos dentes. Após anamnese, exame clínico e radiográfico, o plano de tratamento proposto foi de harmonizações periodontal com aumento de coroa e enxerto gengival, além de coroas em cerâmicas de dissilicato de lítio. Dentro desse contexto, mostra-se que uma abordagem multidisciplinar para reabilitação estética e funcional do sorriso é fundamental, a qual nos proporciona equilíbrio e naturalidade entre estética branca e vermelha no resultado do tratamento reabilitador(AU)


Aesthetics plays an important role in people's acceptance and self-esteem and, as a result, patients increasingly seek to have a harmonious smile. Aesthetic rehabilitations must involve a complete planning, linking function and aesthetics, evaluating tooth size, gingival profile and heights, smile height and buccal corridor. Because of this, dentistry allows us a series of different therapeutic approaches that reach satisfactory results for the patient. Therefore, the present work aims to describe a case report of a patient with an aesthetic complaint of her smile due to different shades, shapes and sizes of teeth. After anamnesis, clinical and radiographic examination, the proposed treatment plan was periodontal harmonization with crown augmentation and gingival graft, in addition to lithium disilicate ceramic crowns. Within this context, it is shown that a multidisciplinary approach to the aesthetic and functional rehabilitation of the smile is fundamental, which provides us with balance and naturalness between white and red aesthetics in the result of the rehabilitation treatment(AU)


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Cerâmica , Coroas , Estética Dentária , Gengiva/transplante , Aumento da Coroa Clínica , Facetas Dentárias , Gengivoplastia , Lítio
4.
Rev. Odontol. Araçatuba (Impr.) ; 44(2): 60-66, maio-ago. 2023. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1428073

RESUMO

Sorriso gengival é comumente conhecido pela exposição excessiva das gengivas ao sorrir, acarretando assim na diminuição das coroas dos elementos. No que tange a etiologia dessa condição, ela se apresenta de maneiras diversas e sua identificação é fundamental para o desenvolvimento de um plano de tratamento eficaz. O planejamento clínico pode ser feito usando uma abordagem dinâmica e digital do sorriso, como softwares, exames de imagem, modelos virtuais 3D e guias cirúrgicos, melhorando a qualidade e precisão do tratamento, oferecendo diversos benefícios aos pacientes. Sendo assim esse estudo teve como objetivo demonstrar a importância dos processos digitais no planejamento e correção do sorriso gengival. Paciente queixou-se da desproporção do sorriso, caracterizado por coroas curtas nas regiões de pré-molares e incisivos ligadamente com a exposição excessiva da gengiva ao sorrir. Após estudos clínicos e de imagem, a etiologia foi diagnosticada como erupção passiva alterada, tipo I (fenótipo espesso). O tratamento de escolha foi o remodelamento gengival associado à osteotomia e osteoplastia obtendo assim uma maior precisão no tratamento, sendo confeccionado um guia cirúrgico duplo. Sendo assim, é possível contemplar que o planejamento digital permite uma maior previsibilidade da execução, compatibilidade em relação a expectativa do paciente e profissional, além da total individualização do caso, tornando os resultados mais favoráveis e exatos e minimizando as chances de iatrogenias(AU)


Gummy smile is commonly known for exposing the gums to the smile, thereby increasing the crowns elevation of the elements. Regarding a condition, it presents itself in different ways and its identification is fundamental for the development of a treatment plan. The clinician can be done using a dynamic and digital approach to image treatment, such as software, imaging exams, various 3D virtual models and elaborate guides, improving the quality and precision of treatment, offering benefits to patients. Therefore, this study aimed to demonstrate the importance of digital processes in planning and correcting the gummy smile. Patient complained of disproportion of the smile, facing the regions of premolar crowns and incisors of the smile, facing the exposure of the gingiva when smiling. After clinical and imaging exams, the diagnostic studies were diagnosed as passive eruption, type I (phenotype and specific). The choice of choice was remodeling associated with surgery treatment and surgery treatment, thus providing a greater precision in the treatment, being a double guide elaborated. Therefore, it is possible that the digital is possible a predictability of execution, compatibility in relation to patient and professional care, in addition to the greater possibility of individualization planning than it allows, making the results more planned as possibilities and exactly the iatrogenic(AU)


Assuntos
Humanos , Feminino , Adulto , Planejamento , Gengivoplastia , Osteotomia , Dente Pré-Molar , Coroas , Imageamento Tridimensional , Gengiva
5.
Rev. Odontol. Araçatuba (Impr.) ; 44(1): 39-46, jan.-abr. 2023. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1427882

RESUMO

Introdução: A procura pela estética do sorriso é crescente na Odontologia, pois, muitas vezes um sorriso alinhado e periodonto saudável não são o bastante. A cerâmica odontológica apresenta-se como uma ótima possibilidade restauradora, visto o avanço das técnicas de adesão entre o substrato dentário e as cerâmicas, torna-se mais previsível o resultado com este tipo de reabilitação. Objetivo: O presente artigo tem como objetivo descrever um caso clínico com envolvimento de diversos níveis de desgaste dentário para reabilitação estética com cerâmica de dissilicato de lítio. Relato de caso: Paciente 36 anos, gênero feminino, apresentava insatisfação com seu sorriso devido a forma e a alteração de cor dos seus dentes superiores anteriores e pré-molares. O plano de tratamento consistiu em realizar a troca da coroa metalocerâmica por coroa total cerâmica da unidade 14, coroa total cerâmica nas unidades 11, 21 e 22, facetas cerâmicas nas unidades 15, 13, 12, 23, 24 e 25, osteotomia e gengivoplastia das regiões de 2º prémolar superior esquerdo ao 2º pré-molar superior direito, clareamento dental caseiro da arcada inferior e placa oclusal superior de proteção. O material de escolha para a resolução do caso clínico foi a cerâmica vítrea reforçada à base de dissilicato de lítio, pois, possui um índice de refração de luz semelhante à estrutura dentária, sem interferência significativa da translucidez, além de ser passível de cimentação adesiva por se tratar de uma cerâmica ácido sensível e o tamanho do cristal e a sua disposição favorecem o aumento das propriedades mecânicas da restauração. Conclusão: O plano de tratamento realizado permitiu o restabelecimento da função e estética, com reprodução das características dos dentes naturais e promoção da jovialidade e da harmonia no sorriso(AU)


Introduction:The demand for smile aesthetics is growing in Dentistry, because, often a smile aligned and healthy periodontium are not enough. Dental ceramics, presented as an excellent restorative possibility, since the advancement of adhesion techniques between the dental substrate and the ceramics, becomes more predictable the result with this type of rehabilitation. Objective: This article aims to describe a clinical case involving several levels of dental wear for aesthetic rehabilitation with ceramics. Case Report: A 36-year-old female patient presented dissatisfaction with her smile due to the shape and color alteration of her anterior and premolar upper teeth. The treatment plan consisted of exchanging the metal-ceramic crown for the total ceramic crown of unit 14, total ceramic crown in units 11, 21 and 22, ceramic veneers in units 15, 13, 12, 23, 24 and 25, osteotomy and gingivoplasty of the regions from 2nd left upper premolar to 2nd right upper premolar, home tooth whitening of the lower arch and upper occlusal plate of protection. The material of choice for the resolution of the clinical case was the glass ceramic reinforced on the basis of lithium disilicate because it has a refractive index of light similar to the dental structure, without significant interference of translucency, besides being liable to adhesive cementation because it is a sensitive acid ceramic and the size of the crystal and its disposition favor the increase of the mechanical properties of the restoration. Conclusion: The treatment plan performed allowed the restoration of function and aesthetics, with reproduction of the characteristics of natural teeth and promotion of joviality and harmony in the smile(AU)


Assuntos
Humanos , Feminino , Adulto , Cerâmica , Coroas , Facetas Dentárias , Estética Dentária , Lítio , Osteotomia , Clareamento Dental , Periodonto , Placas Oclusais , Desgaste dos Dentes , Gengivoplastia
6.
Rev. Flum. Odontol. (Online) ; 1(60): 147-160, jan.-abr. 2023. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1411400

RESUMO

Introduction: The goal of this pilot study was to evaluate the differences between checking occlusion on implants crowns using 16 or 200 µm thickness of articulating occlusal paper, and to compare the stained occlusal area between the groups after bite forces of 200 and 250 N. Methods: It was included 10 casts of articulated-type IV gypsum, 10 NiCr crowns, articulating occlusal papers (16 µm and 200 µm thick), and a compression test machine. Compressive forces (200 and 250 N.mm) were applied on models, to check the occlusal contact area of fixed and cemented crowns. The contact areas on the crowns were measured through images obtained by the scanning electron microscope. Statistical tests were performed considering the significant level of 5% (p≤0.05). Results: The stains found using 200 µm of articulating paper were higher than those with 16 µm, independent of the force applied. However, the stains obtained in lower teeth with different strengths (200 and 250N) marked with 16 µm articulating paper were not possible to score. The articulating paper variable had significant statistical results (p=0.002), while the variables force (p=0.443) and articulating paper-force interaction (p=0.607) were not significant. The mean area found in staining using the 200 µm and 16 µm papers was, respectively, 8.3380 mm2 and 3.4759 mm2. Conclusion: It was possible to confirm that 200 µm of articulating occlusal paper showed better and significant results to stain the occlusal area, permitting a more accurate adjustment independent of the force applied.


Assuntos
Força de Mordida , Implantes Dentários , Força Compressiva , Coroas , Articuladores Dentários , Oclusão Dentária , Dente Molar
7.
São José dos Campos; s.n; 2023. 67 p. ilus, tab.
Tese em Português | BBO - Odontologia | ID: biblio-1435875

RESUMO

O presente estudo teve como objetivo caracterizar a microestrutura de uma resina temporária de impressão 3D (Resilab Temp), avaliando as propriedades óticas, o comportamento mecânico e a resistência à tração de coroas cimentadas com diferentes cimentos temporários. Todas as propriedades foram também avaliadas após a simulação de envelhecimento térmico. Para a análise da microestrutura superficial e estabelecimento do melhor padrão de impressão, amostras em formato de barras seguindo a ISO 4049 (25 x 10 x 3 mm) foram desenhadas em software (Rhinoceros 6.0), impressas na impressora W3D (Wilcos do Brasil) e fotopolimerizadas na Anycubic Photon em diferentes tempos (sem cura, 16 minutos, 32 minutos e 1 hora). Para a caracterização estrutural foram realizadas as análises em FTI-R (Espectroscopia de infravermelho com transformada de Fourier) e Microscopia Eletrônica de Varredura (MEV). O comportamento mecânico da resina foi feito com base nos testes de resistência à flexão, mensuração do módulo elástico e microdureza de Knoop. A análise de cor e translucidez foi feita com um espectrofotômetro (VITA Easy shade Advanced 4.0), o qual foi avaliado seguindo o CIELab, utilizando os fundos cinza, preto e branco. Todas as análises foram realizadas imediatamente após a confecção das amostras e repetidas após o envelhecimento térmico com 2 mil ciclos (5-55 C). Coroas de resinas foram fabricados da mesma forma que os espécimes anteriores e foram cimentadas sobre preparo padronizados em resina Nema G10 (análogo à dentina). Foram usados 3 cimentos temporários: hidróxido de cálcio (HC), óxido de zinco sem eugenol (OZNE) e ionômero de vidro (IOV). Os espécimes foram ensaiados com teste de resistência à tração das coroas, antes e após o mesmo envelhecimento térmico. Os resultados obtidos foram analisados estatisticamente com nível de significância de 5%. A análise de FTI-R mostrou cerca de 46% de grau de conversão na superfície e 37% no centro da amostra da resina. A resistência à flexão foi maior para os grupos polimerizados por 32 min e 1h, enquanto a microdureza Knoop não apresentou diferença estatística entre os grupos. A análise translucidez também não mostrou diferenças estatísticas entre os grupos, entretanto a cor foi alterada pelo tempo de polimerização e envelhecimento. No ensaio de resistência à tração, todos os fatores mostraram diferenças estatisticamente significantes. Antes do envelhecimento, o grupo IOV foi estatisticamente superior ao HC e OZNE; Entretanto, após o envelhecimento, não houve diferença entre os grupos. De acordo com todas as análises realizadas nesse estudo, o tempo de pós polimerização de 1 hora apresentou o melhor desempenho mecânico e estabilidade de cor, e o cimento de ionômero de vidro possui a melhor retenção imediata após a cimentação, apesar de todos os cimentos temporários usados no estudo possam ser indicados. (AU)


The present study aimed to characterize the microstructure of a 3D printing temporary resin (Resilab Temp), evaluating the optical properties, mechanical behavior and tensile strength of crowns cemented with different temporary cements. All properties were also evaluated after simulated thermal aging. For surface microstructure analysis, bar-shaped specimens following ISO 4049 (25 x 10 x 3 mm) were designed in software (Rhinoceros 6.0), printed in the W3D printer (Wilcos do Brasil) (n=36) and photopolymerized in the Anycubic Photon at different times (no curing, 16 minutes, 32 minutes and 1 hour). For structural characterization FTI-R (n=72) (Fourier transform infrared spectroscopy) and Scanning Electron Microscopy (SEM)(n=4) analyses were carried out. The mechanical behavior of the resin was done based on flexural strength tests, elastic modulus measurement (n=12) and Knoop microhardness (n=20). The color and translucency analysis was done with a spectrophotometer (n=40) (VITA Easy shade Advanced 4.0), which was evaluated following the CIELab, using the gray, black and white backgrounds. All analyses were performed immediately after making the samples and repeated after thermal aging with 2,000 cycles (5-55 C). Resin crowns were fabricated (n=48) in the same manner as the previous specimens and were cemented on standardized preparations in Nema G10 resin (dentin analog). Three temporary cements were used: calcium hydroxide (HC), zinc oxide without eugenol (OZNE) and glass ionomer (IOV). The specimens were tested with crown tensile strength test before and after the same thermal aging. The results obtained were statistically analyzed with 5% significance level. FTI-R analysis showed about 46% degree of conversion on the surface and 37% in the center of the resin sample. The flexural strength was higher for the groups polymerized for 32 min and 1h, while Knoop microhardness showed no statistical difference between groups. Translucency analysis also showed no statistical difference between groups, however the color was altered by polymerization time and aging. In the tensile strength test, all factors showed statistically significant differences. Before aging, the IOV group was statistically superior to HC and OZNE; however, after aging, there was no difference between the groups. According to all analyses performed in this study, the 1-hour post-curing time showed the best mechanical performance and color stability, and the glass ionomer cement has the best immediate retention after cementation, although all temporary cements used in the study can be indicated (AU)


Assuntos
Envelhecimento , Cor , Coroas , Cimentos Dentários , Impressão Tridimensional
8.
Braz. j. oral sci ; 22: e237338, Jan.-Dec. 2023. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1397295

RESUMO

Aim: Endocrown restorations are commonly used to rehabilitate endodontically treated posterior teeth and their use is well-founded in these cases. However, to date, there is little scientific evidence of their behavior in anterior teeth. The aim of this in vitro study was to evaluate the compressive strength of upper central incisors teeth, restored with glass-ceramic total crowns by the conventional anatomical core technique, and compare them to teeth restored with endocrowns with and without the presence of ferrule. Methods: Thirty teeth were randomly distributed into three groups: GE2 - endocrown group with 2 mm ferrule, GE0 - endocrown group without a ferrule, and GC - conventional crown with intraradicular post group. Crowns were cemented and teeth submitted to the 45o compression test until the fracture happened. Fractured specimens were analyzed to determine the fracture pattern. Descriptive analysis of the variables was performed and one-way analysis of variance was utilized to analyze the data for significant differences at p < 0.05. Results: The results of the control group (284.5 ± 201.05N) showed the highest fracture resistance value, followed by the 2mm group (274.54 ± 199.43N) and by the 0mm group (263.81 ± 80.05N). There was no statistically significant difference between all the groups (p = 0.964). Conclusions: The absence of a cervical enamel necklace favored a debonding of the pieces and endodontically treated anterior teeth could be restored with endocrown, which could be considered a conservative and viable treatment option


Assuntos
Desenho Assistido por Computador , Coroas , Endodontia , Resistência à Flexão
9.
Braz. j. oral sci ; 21: e225136, jan.-dez. 2022. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1354771

RESUMO

Aim: To evaluate the influence of cobalt-chromium (Co-Cr) coping fabrication methods and ceramic application on the marginal and internal fit of metal-ceramic crowns. Methods: Co-Cr copings for metal-ceramic crowns were prepared by lost wax casting or CAD-CAM machining of sintered blocks. The fit was analyzed using the silicone replica technique at four assessment points: marginal gap (MG), axial wall (AW), axio-occlusal (AO) angle, and central occlusal (CO) wall. After the initial analysis, the copings were ceramic-veneered with the layering technique, and the fit was again determined. Data were statistically analyzed by paired and unpaired Student's-t test (α=0.05). Results: Marginal and internal fit before ceramic application according to the coping manufacturing method showed significant differences only at CO (p < 0.001), with milled copings (137.98±16.71 µm) showing higher gap values than cast copings (112.86±8.57 µm). For cast copings, there were significant differences at MG (before 109.13±8.79 µm; after 102.78±7.18 µm) and CO (before 112.86±8.57 µm; after 104.07±10.63 µm) when comparing the fit before and after ceramic firing. For milled copings, there was significant difference only at AO (before 116.39±9.64 µm; after 108.54±9.26 µm). Conclusion: This study demonstrated that the coping fabrication method influenced the internal fit. Ceramic firing maintained or improved the fit of the metal-ceramic crowns. The marginal discrepancy of all restorations, before and after ceramic firing, can be considered clinically acceptable


Assuntos
Cerâmica , Ligas Metalo-Cerâmicas , Adaptação Marginal Dentária , Coroas
10.
Natal; s.n; 25 nov. 2022. 81 p. tab, ilus.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1532247

RESUMO

A estética e estabilidade dos tecidos moles e ósseo ao redor do implante é um componente crítico para o sucesso do implante em longo prazo e pode ser influenciado por fatores como os tipos de conexões protéticas. OBJETIVO: Comparar o comportamento do tecido peri-implantar em reabilitação com coroas implantossuportadas cimentadas na região estética usando um pilar protético pré-fabricado em titânio (GT) e um pilar protético personalizado em zircônia (GZ). METODOLOGIA: Neste estudo longitudinal do tipo ensaio clínico controlado, cego e não randomizado, 30 coroas cimentadas sobre implantes dentários unitários em região estética anterior foram alocados sequencialmente: 15 reabilitados sobre um sistema de implante com pilar protético pré-fabricado em titânio (GT) e 15 sobre um sistema de implantes com pilar protético personalizado em zircônia (GZ). O comportamento do tecido peri-implantar foi avaliado em T0 (início do condicionamento tecidual), T1 (fim do condicionamento tecidual), T2 (7 dias após cimentação final), T3 (6 meses após cimentação final). Índice de Placa Visível (IPV), Índice de Sangramento Gengival (ISG), Sangramento a sondagem (SS), Profundidade de Sondagem (PS), Relação Altura/Largura da papila interdental (AP/LP), Faixa de Mucosa Ceratinizada (MC), Espessura gengival (EG), Fenótipo periodontal (FP), Recessão Gengival (RG), distância radiográfica da crista óssea para o ponto de contato e Pink Esthetic Score (PES) foram avaliados. A análise dos dados foi realizada utilizando os seguintes testes estatísticos: Friedman, Mann-Whitney e Qui- quadrado/Exato de Fisher, com nível de significância de 5%. RESULTADOS: Não houve diferenças estatísticas significativas entre os grupos para nenhum dos parâmetros clínicos periodontais nos tempos avaliados (p>0,05). Entretanto, a análise intragrupo mostrou uma redução estatística no IPV e ISG entre T1 e T2 apenas para o GZ (p<0,05). Houve diminuição significativa entre os tempos T0 e T3 para o parâmetro de EG (1,67 mm - 1,47 mm no GT; 1,70 mm -1,47mm no GZ) e aumento da razão AP/LP (0,56 ­ 0,80 no GT; 0,70-0,83 no GZ) em ambos os grupos (p<;0.001). O PES também aumentou significativamente para ambos os grupos (9 ­ 12 no GT; 7 ­ 12 no GZ) de T0 para T1, mantendo-se elevado nos demais tempos analisados. CONLUSÃO: Os resultados mostraram que os pilares protéticos utilizados não impactaram em diferenças nas variáveis clínicas e estética relacionadas ao comportamento dos tecidos periimplantares ao longo do tempo. Sendo assim, a decisão pela seleção dos componentes para a reabilitação em região estética poderia se basear em aspectos como o custo, fluxo e tempo de trabalho (AU).


The esthetics and stability of the soft tissue and bone around the implant is a critical component to the long-term success of the implant and can be influenced by factors such as the type of prosthetic connections. OBJECTIVE: To compare the behavior of the periimplant tissue of single implant-supported crowns in the anterior aesthetic area using prefabricated titanium prosthetic abutments (GT) and customized zirconia prosthetic abutments (GZ). METHODOLOGY: In this controlled, blinded, non- randomized clinical trial, 30 single cemented crown over anterior implants were sequentially allocated: 15 implants rehabilitated on implant system with a prefabricated titanium prosthetic abutment (GT) and 15 on implant system with customized zirconia prosthetic abutment (GZ). The behavior of the peri- implant tissue was evaluated at T0 (beginning of tissue conditioning), T1 (end of tissue conditioning), T2 (7 days after final cementation), T3 (6 months after final cementation). Visible Plaque Index (VPI), Gingival Bleeding Index (GBI), Bleeding on Probing (BoP), Probing Depth (PD), Interdental Papilla Height/Width Ratio (PH/PW), Keratinized Mucosa Width (KM), Gingival Thickness (PT), Periodontal Phenotype (PF), Gingival Recession (GR), radiographic distance from the bone crest to the contact point and Pink Esthetic Score (PES) were registered. The results were analyzed with the following statistical tests: Friedman, Mann-Whitney and Chi- square/Fisher; Exact test with a significance level of 5%. RESULTS: No statistically significant differences were observed between groups for any of the clinical parameters in any, (p>0.05). However, intragroup analysis showed a statistical reduction in VPI between T1 and T2 only for GZ (p< 0.05). There was a significant decrease between T0 and T3 for GT (1.67 mm - 1.47 mm in GT, and 1.70 mm -1.47 mm in GZ) and increase in the ratio PH/PW (0.56 - 0.80 in GT and 0.70- 0.83 in GZ) in both groups (p<0.0001). PES also increased significantly for both groups (9 ­ 12 in GT and 7 ­ 12 in GZ) from T0 to T1 and remained high in the other periods. CONCLUSION: The results showed that the prosthetic abutments used did not impact differences in clinical and aesthetic variables related to the behavior of peri-implant tissues during the study. Therefore, the decision to select components an aesthetic area should be based on aspects such as cost, workflow and timing (AU).


Assuntos
Condicionamento de Tecido Mole Oral , Prótese Dentária Fixada por Implante , Estética Dentária , Distribuição de Qui-Quadrado , Estudos Longitudinais , Estatísticas não Paramétricas , Coroas , Implantação Dentária , Reabilitação Bucal
11.
Rev. Odontol. Araçatuba (Impr.) ; 43(1): 51-56, jan.-abr. 2022. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1361718

RESUMO

Este trabalho teve como objetivo apresentar um relato de caso clínico de uma restauração do tipo coroa endocrown cerâmica em um dente molar tratado endodonticamente. Paciente com 45 anos de idade, sexo feminino, procurou a clínica do Centro Universitário da Serra Gaúcha (FSG) relatando a necessidade de reabilitação protética no primeiro molar inferior do lado esquerdo. Com base no exame radiográfico e exame clínico foi constatado um primeiro molar inferior do lado esquerdo com tratamento endodôntico satisfatório, mas uma extensa destruição coronária. Após a aprovação da paciente e indicações para a utilização da técnica, optou-se pela confecção de uma coroa endocrown em cerâmica reforçada por dissilicato de lítio. Foi realizado o preparo do remanescente dentário, envolvendo a câmara pulpar, com ângulos arredondados e expulsivos e, após a moldagem do mesmo com silicone de adição, utilizando a técnica simultânea e duplo fio. O provisório foi realizado com resina quimicamente ativada na cor 62 e, na sessão seguinte a coroa endocrown foi ajustada e polida. Após receber o protocolo de condicionamento adequado da peça, a mesma foi cimentada com cimento autopolimerizável Multilink N. Pode-se concluir que a alternativa restauradora Endocrown é um tratamento conservador e favorável para dentes com extensa destruição coronária, permitindo adequada estética e função(AU)


This study aimed to present a clinical case report of an endocrown ceramic crown restoration in na endodontically treated molar tooth. A 45-year-old female patient sought the clinic at the Centro Universitário da Serra Gaúcha (FSG), reporting the need for prosthetic rehabilitation on the lower left first molar. Based on the radiographic and clinical examination, the first molar presented satisfactory endodontic treatment, but extensive coronary destruction. After the approval of the patient and indications for the use of the technique, it was decided to make an endocrown with reinforced ceramic by lithium disilicate. The remaining tooth was prepared, involving the pulp chamber, with rounded and expulsive angles and, after the impression with silicone using the simultaneous and double wire technique was taken. The provisional was made with chemically activated resin in color 62 and, in the following session, the endocrown crown was adjusted and polished. After receiving the proper conditioning protocol, it was lutted with Multilink N self-curing cement. It can be concluded that the Endocrown restorative alternative is a conservative and favorable treatment for teeth with extensive coronary destruction, allowing adequate aesthetics and function(AU)


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Cerâmica , Dente não Vital , Coroas , Dente Molar , Prótese Dentária , Cavidade Pulpar , Retenção da Prótese
12.
São José dos Campos; s.n; 2022. 77 p. tab, ilus, graf.
Tese em Português | BBO - Odontologia | ID: biblio-1397199

RESUMO

Este estudo avaliou o efeito da ausência das paredes axiais residuais e/ou faces livres da estrutura coronária remanescente no comportamento biomecânico e em fadiga de incisivos centrais tratados endodonticamente com coroas totais e férula de 2 mm. Raízes de incisivos bovinos foram distribuídas em 4 grupos de n = 10: Férula completa de 2 mm (FER-2), remanescente com altura de 2 mm nas paredes vestibular e palatino (FER-VP); remanescente com altura de 2 mm nas paredes mesial e distal (FER-MD) ; ausência de férula (FER-0), associados ao fator ausência de pino. Os grupos foram submetidos ao ensaio de fadiga stepwise stress (50.000 ciclos/degrau; 5 Hz; carga=200N a 980N; degrau=40N, até a fratura). O carregamento foi feito por um aplicador em aço inoxidável com ponta arredondada, a 2 mm acima do cíngulo em um ângulo de 30°. Em um software de análise por elementos finitos (FEA), as distribuições de tensões foram avaliadas pelo o critério de Tensão Máxima Principal seguindo os mesmos parâmetros do ensaio in vitro, porém, associando os fatores experimentais a ausência e presença de pino, no qual os materiais foram considerados homogêneos, linearmente elásticos e isotrópicos, exceto os pinos de fibra de vidro, que foram considerados ortotrópicos e após o teste de convergência de malhas em 10%, obteve uma média de 72.719 elementos tetraedros e 128.756 nós. Para a fadiga, carga e o degrau da falha foram analisados pela estatística de Kaplan-Meier e Mantel-Cox (Log Rank test) (α=5%). Os dados de sobrevivência em função do carregamento oblíquo detectaram diferenças estatísticas entre as condições analisadas (Mantel-Cox LogRank test for trend, X2=0,015, df=1, p=0,901), no qual, 100% das amostras sobreviveram ao carregamento até 200N. O modo de falha predominante foi fratura não restaurável 1/3 radicular. Os resultados de FEA demonstraram que não houve diferença significativa entre os grupos com e ausência de pinos, sendo possível verificar que realizar restaurações intrarradiculares sem pino em raízes não fragilizadas, com no mínimo 2 mm de altura e 1 mm de espessura de férula parcial ou total é uma boa opção de tratamento. (AU)


This study was divided in two part, in vitro and in silic, with the purpose to evaluate the effect of the absence of residual axial walls and/or free faces of the remaining coronary structure on the biomechanical behavior and fatigue of endodontically treated central incisors with total crowns. Forty roots of bovine incisors was be distributed in 4 groups (n = 10): complete ferrule of 2 mm (FER2): remaining 2 mm high in the buccal and lingual walls (FER-VP); remaining 2 mm high in the mesial and distal walls (FER-MD); absence of ferrule (FER-0), all without post. The groups will be submitted to the stepwise stress fatigue test (172,000 cycles / step; 4 Hz; load = 200N to 450N; step = 50N, until the fracture). The load will be applied 2 mm above the cingulum (30 °) with a rounded steel tip. In silico test, the stress distributions was evaluated by the Maximum Principal Stress criterion following the parameters and groups of the in vitro test, and adding posts. The materials were considered homogeneous, linearly elastic and isotropic, except for the fiberglass posts, which were considered orthotropic. After the mesh convergence test at 10%, it obtained an average of 72,719 tetrahedral elements and 128,756 nodes. For fatigue, load and the failure step will be analyzed by the Kaplan-Meier and Mantel-Cox (Log Rank test) (α = 5%). The survival data as a function of oblique loading detected statistical differences between the conditions analyzed (Mantel-Cox Log-Rank test for trend, X2=0,015, df=1, p=0,901), in which 100% of the samples survived loading up to 200N. The predominant failure mode was a non-repairable 1/3 root fracture. The FEA results showed that was no significant difference betwen the groups with and without posts. It was possible to verify that intrarradicular restorations without post on non fragile roots with at least 2mm in height and 1mm of partial or total ferrule thickness is a good treatment option (AU)


Assuntos
Animais , Bovinos , Dente não Vital , Coroas , Fadiga , Ferula
13.
Arq. odontol ; 58: 216-226, 2022. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1412034

RESUMO

Objetivo: O presente trabalho tem como objetivo avaliar o conhecimento dos odontopediatras e suas percepções, conhecendo as dificuldades que estes encontram frente ao desafio da reabilitação de dentes decíduos. Métodos: A pesquisa foi realizada por meio da aplicação de questionários on-line e a análise estatística foi descritiva e comparativa, com tabelas de frequência para as variáveis quantitativas. O teste não paramétrico de Qui-quadrado foi utilizado para estimar a associação entre as diferentes categorias dos dados e em todo o estudo, estipulou-se o nível de significância em 5%. Resultados: Os resultados da pesquisa mostraram que a maioria dos entrevistados conhecem as coroas pré-fabricadas de aço, porém sua aplicação em atendimentos de crianças com extensas destruições coronárias limita-se a 34,1% destes profissionais, sendo que a baixa utilização se deve à dificuldade de aquisição do material e falta de habilidade técnica. Já com relação às coroas pré-fabricadas de zircônia, 82,4% das odontopediatras as conhecem, mas a grande maioria não as utiliza devido à dificuldade de aquisição, falta de habilidade técnica e o seu alto custo. Não foi encontrada associação entre a dificuldade de planejamento dos casos e a consideração estética e o âmbito de trabalho do entrevistado, bem como o fato de conhecer as coroas pré-fabricadas e utilizá-las. Conclusão: Conclui-se que os materiais reabilitadores, como coroas pré-fabricadas de aço e de zircônia, são de certa forma bem conhecidos pelos odontopediatras, mas sua utilização em reabilitação de dentes decíduos ainda é limitada.


Aim: The present study aims to evaluate the knowledge of pediatric dentists and their perceptions, knowing the difficulties they face in the challenge to rehabilitate deciduous teeth. Methods: This study was carried out through the application of online questionnaires. The statistical analysis was descriptive and comparative, with frequency tables for the quantitative variables. The non-parametric chi-square test was used to estimate the association between the different categories of data, and the significance level was set at 5%. Results:The survey results showed that most respondents know about prefabricated steel crowns, but their application in the care of children with extensive coronary destruction is limited to 34.1% of these professionals. The low use is due to the difficulty of acquiring the material and the lack of technical skills. It was found that 82.4% of the pediatric dentists have knowledge about prefabricated zirconia crowns, but the vast majority do not use them due to the difficulty of acquisition, their lack of technical skills, and the product's high cost. No association was found between the difficulty of planning the cases and the esthetic consideration and sphere of work of the interviewee, nor regarding the fact of their having knowledge about the prefabricated crowns and using them. Conclusion: It can therefore be concluded that rehabilitation materials, such as prefabricated steel and zirconia crowns, are well-known by pediatric dentists, but their use in the rehabilitation of deciduous teeth is still limited.


Assuntos
Dente Decíduo , Coroas , Cárie Dentária , Reabilitação Bucal
14.
São José dos Campos; s.n; 2022. 50 p. tab, ilus.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1414515

RESUMO

Os implantes osseointegrados têm sido utilizados desde a década de 50, conforme a utilização dos implantes vem crescendo, suas complicações também aumentam, principalmente quando são instalados em áreas estéticas, onde há deficiência de tecido conjuntivo peri-implantar. O objetivo deste estudo longitudinal prospectivo com 4 anos de acompanhamento foi avaliar o aumento da espessura de tecido conjuntivo peri-implantar em implantes instalados em áreas estéticas com a utilização de enxerto de tecido conjuntivo. Uma amostra de 34 indivíduos foi utilizada de um estudo prévio, o grupo teste (n=16) recebeu enxerto de tecido conjuntivo (ETC) sobre os implantes e o grupo controle (n=18) apenas o implante dental, o estudo tem um "power" de 80% (p=0,05). Após a instalação das coroas, os pacientes foram acompanhados pelo período de 4 anos, baseline, 12 meses e 48 meses, e as seguintes análises foram realizadas: Espessura tecido periimplantar vestibular (EV), deiscência óssea (DO), altura do tecido queratinizado (AQ), avaliação estética (PES/WES e Índice de Jent), avaliação estética pelo paciente (VAS), melhora da qualidade de vida (OHIP) e medidas radiográficas (COm/d). Resultados: A análise entre os grupos não foi estatisticamente significativa para as variáveis AQ, COm/d, PES/WES, Índice de Jent, estética centrada no paciente e OHIP. A análise intragrupos da COm/d foi significante em todos os períodos, tanto no teste quanto no controle. Para AQ, houve diferença no grupo controle entre o baseline e os demais períodos; na EV do grupo teste houve uma diferença significante entre o baseline e 48 meses e entre os dados de 12 e 48 meses, observando-se uma diminuição da EV, OHIP houve diferença em ambos os grupos, entre início e fim de tratamento, já as comparações entre os grupos para as variáveis EV e COm/d foram estatisticamente significante , EV apresentou maiores valores no grupo teste e Com/d menores valores no controle .Conclusão: A colocação de ETC aumenta espessura de tecido mole e após 48 meses mantem a espessura de EV, melhora DO, não aumenta AQ, não melhora a estética do ponto de vista do paciente e do profissional e a qualidade de vida não difere daqueles que receberam apenas o implante (AU)


Osseointegrated implants have been used since the mid-1950s. As the use of implants has grown, their complications also increase, especially those installed in esthetic areas, when there is a deficiency of peri-implant connective tissue. The aim of this prospective longitudinal study with 4 years of follow-up was to evaluate the increase in peri-implant connective tissue thickness in implants placed in esthetic areas using a connective tissue graft. Thrity-four patients froma previous study were divided in two groups:Test group (n=16), which received connective tissue graft (CTG) over the implants and Control group (n=18), which only the dental implant was installed. the study has a power of 80% (p=0.05). After dental crown placement, the patients were followed for a period of 4 years ( baseline, 12 months and 48 months) and the following analyzes were performed: Peri-implant tissue thickness buccal (EV), bone dehiscence (BD), height of keratinized tissue (KT), aesthetic evaluation (PES/WES and Jent Indexand by patient (VAS), quality of life (OHIP) and radiographic measurements (COm/d) Results: The analysis between groups was not significant for the variables KT, COm/d, PES/WES, Jent Index, patient-centered aesthetics and OHIP. The intragroup analysis of COm/d was significant in all periods in both test and control groups. For KT, there was a difference in the control group between the baseline and the other periods; in the EV of the test group there was a significant difference between the baseline and 48 months and between 12 and 48 months, showing a decrease in EV. In relation to OHIP, there was a difference in both groups, between baseline and 48mo.Comparisons between groups for the variables EV and COm/d were statistically significant, EV presented higher values in the test group and COm/d lower values in the control. Conclusion: CTG increased soft tissue thickness and after 48 months maintained the EV thickness, improved DO, did not increase KT, did not improve esthetics from patient's point of view neither the professional, and the quality of life did not differ from those who received only the implant (AU)


Assuntos
Humanos , Implantes Dentários , Tecido Conjuntivo , Coroas
15.
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1365234

RESUMO

ABSTRACT Objective To evaluate the marginal adaptation of computer-aided designing and computer-aided machining (CAD/CAM) fabricated cobalt-chromium and zirconium-oxide-based ceramic crowns compared to those produced by a conventional method. Material and Methods The study consists of three groups; 45 crowns fabricated from cobalt-chromium (CAD-CoCr) and 45 crowns manufactured from zirconium CAD/CAM technology (CAD-Z), and 45 control (C) which consists of conventional metal-ceramic crowns. The marginal discrepancies in vertical dimensions were assessed utilizing a microscope in four surfaces (mesial, distal, vestibular, and oral) for each crown. On completion of the microscopic evaluation, multivariate analysis of variance (MANOVA) was used to study the difference in the four surfaces, considered altogether. Two-way ANOVA revealed the effect of three systems used for gap measurements of each landmark. The differences observed were considered significant at p<0.05. Results There were no differences in the four surfaces revealed by АNOVА in the three groups when considered altogether. Two-way ANOVA of each surface discovered no differences among all groups as well. Conclusion The CAD/CAM crowns revealed a comparable and satisfactory marginal adaptation compared to conventional metal-ceramic crowns.


Assuntos
Zircônio , Ligas de Cromo , Prótese Dentária/instrumentação , Coroas , Porcelana Dentária , Técnicas In Vitro , Análise de Variância , Ligas Metalo-Cerâmicas , Desenho Assistido por Computador , Adaptação Marginal Dentária , Índia
16.
Braz. dent. sci ; 25(2): 1-13, 2022. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1368754

RESUMO

Background: The debonding of crowns and ceramic veneers with laser is already a reality in the clinic. It presents benefits in comparison to traditional removal with the use of a rotating instrument; however, there is still no consolidated protocol and many professionals use it without the necessary scientific basis. Objective: The aim of this work was to perform a literature review on the debonding of indirect ceramic restorations using the Er:YAG and Er,Cr:YSGG lasers to provide clinical professionals and the scientific community a careful analysis, and also to guiding the use of irradiation at laser for such procedures. Methods: Bibliographic searches were performed in the following databases: Pubmed, Web of Science and Google Scholar. According to the inclusion criteria adopted, twenty-seven clinical and in vitro studies were selected in the period from 2007 to 2021. In the present work, the composition of the crowns and facets, as well as the types of cement and the laser irradiation protocols adopted in the selected studies is detailed. Conclusions: It was concluded that the use of erbium lasers for debonding of indirect ceramic restorations proved to be more selective and conservative when compared to removal with a rotary diamond instrument. Furthermore, it was shown to be in more efficient in debonding different types of ceramics. However, there are great variations in the "debonding" protocols, which emphasizes the need for further studies that seek to standardize the irradiation protocols considering the different clinical situations (AU)


Antecedentes: A remoção de coroas e facetas cerâmicas com laser já é uma realidade clínica e apresenta benefícios em relação à remoção tradicional com uso de instrumento rotatório diamantado; entretanto, ainda não existe um protocolo consolidado e muitos profissionais o utilizam sem o embasamento científico necessário. Objetivos: O objetivo deste trabalho foi realizar uma revisão da literatura sobre a remoção de restaurações cerâmicas indiretas utilizando os lasers Er:YAG e Er,Cr:YSGG para fornecer uma análise cuidadosa aos profissionais clínicos e à comunidade científica, além de orientar o uso da irradiação a laser para tal aplicação. Métodos: As buscas bibliográficas foram realizadas, nas seguintes bases de dados: Pubmed, Web of Science e Google Scholar. De acordo com os critérios de inclusão adotados, foram selecionados vinte e sete estudos clínicos e in vitro no período de 2007 a 2021. No presente trabalho, a composição das coroas e facetas, bem como os tipos de cimento e os protocolos de irradiação laser adotados nos estudos selecionados foram detalhados. Conclusão: Concluiu-se que o uso dos lasers de érbio para remoção de restaurações cerâmicas indiretas mostrou-se mais seletivo e conservador quando comparado à remoção com instrumento rotatório diamantado, além de ser eficiente na remoção de diferentes tipos de cerâmicas. No entanto, existem grandes variações nos protocolos de "debonding", o que enfatiza a necessidade de novos estudos que busquem uma padronização dos protocolos de irradiação considerando as diferentes situações clínicas.(AU)


Assuntos
Remoção , Coroas , Facetas Dentárias , Lasers de Estado Sólido
17.
São José dos Campos; s.n; 2022. 59 p. tab, ilus, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1369214

RESUMO

Objetivo: Avaliar o comportamento biomecânico do pilar protético Link Universal (TiBase) com diferentes alturas em restaurações implanto-suportadas. Materiais e Métodos: foram utilizados 40 implantes cone morse Titaniumfix Profile (4 x 10 mm) em titânio, divididos em dois grupos (n=20): Link Universal curto (Short) e Link Universal longo (Long). Vinte implantes receberam o pilar protético Link Universal de 4,5 x 4 mm (Short) e vinte implantes receberam o pilar protético Link Universal de 4,5 x 5,5 mm (Long). Por meio da tecnologia CAD/CAM foram usinadas as coroas em zircônia, cimentadas sobre os pilares protéticos. No ensaio de carga máxima para fratura, o grupo Longo apresentou média de 41,1 ± 6,96 kgf, enquanto a média do grupo curto foi de 49,5 ± 7,68, sem diferença estatística entre eles. Os espécimes passaram pelo teste de sobrevivência em fadiga (2.000.000 ciclos na frequência de 2 Hz com aplicador de aço inoxidável de 1,6 mm de diâmetro), conforme parâmetros descritos na ISO 14801:2007 e não apresentaram falhas. Na sequência, foram submetidos ao teste de sobrevivência stepwise, os espécimes não apresentaram diferenças em relação ao número de ciclos para falha, porém, em relação à carga aplicada, o pilar Link Universal Longo mostrou-se mais resistente que o pilar Link Universal Curto. A análise por elementos finitos foi realizada com os parâmetros obtidos no teste stepwise, com aplicação de carga de 450 N em 30º, simulando a condição do teste de fadiga. Os desenhos foram montados com o software Rhinoceros (version 5.4.2 SR8, McNeel Noth America, Seattle, WA, EUA) e processados no software Ansys (version 19.2, ANSYS Inc., Houston, TX, USA). O comportamento biomecânico do conjunto composto por implante, pilar protético, parafuso passante e coroa monolítica foi semelhante entre os grupos. Concluiu-se que ambas alturas da área de cimentação do pilar Link Universal apresentaram comportamento à fadiga favorável à sobrevivência clínica. (AU)


Objective: Evaluate the biomechanical behavior of the Universal Link (Ti-Base) prosthetic abutment with different heights in implant-supported restorations. Materials and Methods: 40 Titaniumfix Profile implants (4 x 10 mm) in titanium were used, divided into two groups (n=20): Short Universal Link (Short) and Long Universal Link (Long). Twenty implants received the 4.5 x 4 mm Link Universal Prosthetic Abutment (Short) and twenty implants received the 4.5 x 5.5 mm Link Universal Prosthetic Abutment (Long). Using CAD/CAM technology, the zirconia crowns were machined and cemented on the prosthetic abutments. In the maximum fracture load test, the Long group presented an average of 41.1 ± 6.96 kgf, while the average of the short group was 49.5 ± 7.68, with no statistical difference between them. The specimens passed the fatigue survival test (2,000,000 cycles at a frequency of 2 Hz with a stainless steel applicator with a diameter of 1.6 mm), according to the parameters described in ISO 14801:2007 and showed no failures. Subsequently, they were submitted to the stepwise survival test, the specimens did not show differences in relation to the number of cycles to failure, however, in relation to the applied load, the Long Universal Link abutment was more resistant than the Short Universal Link abutment. The finite element analysis was performed with the parameters obtained in the stepwise test, with a load of 450 N at 30º, simulating the condition of the fatigue test. The drawings were assembled with Rhinoceros software (version 5.4.2 SR8, McNeel Noth America, Seattle, WA, USA) and processed in Ansys software (version 19.2, ANSYS Inc., Houston, TX, USA). The biomechanical behavior of the set consisting of implant, prosthetic abutment, through screw and monolithic crown was similar between the groups. It was concluded that the Link Universal abutment presented fatigue behavior favorable to clinical survival independently of it's height (AU)


Assuntos
Implantes Dentários , Cimentação , Coroas , Materiais Dentários , Restaurações Intracoronárias
18.
Rev. Ciênc. Plur ; 7(3): 358-367, set. 2021. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1348344

RESUMO

Introduction:The aesthetic rehabilitation of endodontically treated teeth depends on the destruction degree of the crown, the bone support, type of prosthesis, andchewing forces. In these cases, indirect restorations with composite resins are an excellent alternative. The indirect composite resins have improved physical and mechanical properties due toincorporatingof inorganic fillersand multifunctional monomers. These components offer a greater bonding strength to the indirect restorations, which is advantageous for further rehabilitations with ceramic crowns. Objective:To present an aesthetic rehabilitation of anterior teeth with indirect composite resin as a feasible and less expensive treatment alternative.Case Report:Upon clinical examination, extensive and deficient restorations were observed in the upper anterior teeth. The proposed treatment plan was the aesthetic rehabilitation of endodontically treated teeth with indirect restorations using ceromer.Conclusions:This treatment represented an excellent alternative for aesthetic rehabilitation of endodontically treated teeth in cases of great dental crown destruction or small dental absences (AU).


Introdução:A reabilitação estética de dentes tratados endodonticamente depende do grau de destruição da coroa, do dente em questão, do suporte ósseo, do tipo de prótese e dos tipos de forças a que esses dentes serão submetidos. As resinas compostas indiretas apresentam propriedades físicas e mecânicas aprimoradas graças à incorporação de componentes inorgânicos e monômeros multifuncionais com maior número de pontos de união, tornando-os capazes de solucionar os problemas em que seriam indicadas restaurações cerâmicas. Objetivo:Apresentar um relato de caso clínico de uma reabilitação estética de dentes anteriores com resina composta indireta como alternativa de tratamento viável e de menor custo.Relato de Caso:Ao exame clínico foram observadas restaurações amplas e deficientes nos dentes anteriores superiores. O plano de tratamento proposto reabilitação estética dos elementos dentários com cerômeros.Conclusões:Este tratamento representou uma opção viável e demenor custo que pode ser utilizado tanto em situações de grande destruição dentária como em pequenas ausências dentárias, em substituição às restaurações de cerâmica (AU).


Introducción: La rehabilitación estética de los dientes tratados endodónticamente depende del grado de destrucción de la corona, el diente en cuestión, el soporte óseo, el tipo de prótesis y los tipos de fuerzas a las que estos dientes serán sometidos. Las resinas compuestas indirectas tienen propiedades físicas y mecánicas mejoradas gracias a la incorporación de componentes inorgánicos y monómeros multifuncionales con mayor número de puntos de unión, lo que las hace capaces de resolver los problemas en los que estarían indicadas las restauraciones cerámicas. Objetivo: Presentar un caso clínico de rehabilitación estética de dientes anteriores con resina compuesta indirecta como alternativa de tratamiento viable y menos costosa. Reporte de Caso:En el examen clínico, se observaron restauraciones extensas y deficientes en los dientes anteriores superiores. El plan de tratamiento propuesto para la rehabilitación estética de elementos dentales con cerómeros. Conclusiones:Este tratamiento representó una opción viable y menos costosa que se puede utilizar tanto en situaciones de gran destrucción dentaria como en pequeñas ausencias dentales, en sustitución de las restauraciones cerámicas (AU).


Assuntos
Humanos , Feminino , Adulto , Adesividade , Resinas Compostas , Coroas , Reabilitação Bucal/instrumentação , Brasil/epidemiologia
19.
Rev. Odontol. Araçatuba (Impr.) ; 42(2): 24-29, maio-ago. 2021. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1252903

RESUMO

Na Odontologia, o tratamento adequado depende da condição clínica de cada paciente, do conhecimento do profissional e dos materiais empregados. As coroas com sistemas cerâmicos puros se apresentam como excelente alternativa restauradora, demonstrando potencial estético superior ao das coroas metalocerâmicas. Este presente estudo teve como objetivo, relatar um caso clínico onde se realizou uma reabilitação estética de dentes anteriores com coroas de cerâmica pura à base de dissilicato de lítio. O paciente apresentava falta de harmonia e estética entre os dentes anteriores 12,11,21 e 22, na qual foi planejado e executado a reabilitação com coroas E-max desses elementos, bem como a substituição das restaurações dos dentes inferiores anteriores, e também foi realizado a confecção de coroa E-max do dente 35. Concluímos que as reabilitações estéticas de dentes anteriores com coroas de sistemas cerâmicos puros à base de dissilicato de lítio se apresentam como uma excelente alternativa reabilitadora, na qual o tratamento multidisciplinar é um fator considerado essencial, possibilitando restabelecer a estética e a funcionalidade do sorriso do paciente, a fim de alcançar o êxito do tratamento reabilitador(AU)


In dentistry, the appropriate treatment depends on the clinical condition of each patient, the knowledge of the professional and the materials used. Crowns with pure ceramic systems are an excellent restorative alternative, demonstrating an aesthetic potential superior to that of metalloceramic crowns. This present study aimed to report a clinical case where an aesthetic rehabilitation of anterior teeth was performed with crowns of pure ceramic based on lithium disilicate. The patient had a lack of harmony and aesthetics between the anterior teeth 12,11,21 and 22, in which the rehabilitation with E-max crowns of these elements was planned and performed, as well as the replacement of the anterior lower teeth restorations, and was also made the E-max crown of tooth 35. We conclude that the aesthetic rehabilitation of anterior teeth with crowns of pure ceramic systems based on lithium disilicate is an excellent alternative for rehabilitation, in which multidisciplinary treatment is considered an essential factor, making it possible to restore the aesthetics and functionality of the patient's smile, in order to achieve the success of the rehabilitation treatment(AU)


Assuntos
Humanos , Masculino , Adulto , Cerâmica , Coroas , Reabilitação Bucal , Restauração Dentária Permanente , Estética Dentária , Restaurações Intracoronárias
20.
Braz. dent. j ; 32(3): 44-55, May-June 2021. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1345505

RESUMO

Abstract In the RLT (Rapid Layer Technology), veneering ceramic and framework are fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM) and then cemented to obtain the restoration. This study aimed to evaluate the effect of the thickness of veneering ceramic manufactured by the RLT technique on the fracture resistance (FR) of bilayer crowns with zirconia frameworks. Twenty zirconia frameworks and twenty feldspathic posterior crowns with two different veneering ceramic occlusal thicknesses (1mm=TF1; 2mm=TF2) were manufactured using CAD/CAM system. The specimens were luted to an epoxy resin abutment with resin cement and mechanically cycled (200N and 4.5×105 Pa, 37°C, 2×106 cycles, 3Hz). The FR test was performed (10kN, 0.5mm/min), and the specimens were analyzed in a stereomicroscope. For the stress analysis (finite element analysis, FEA), a 10kN load was equal to the in vitro test, and the principal stress was evaluated. The FR data were analyzed by Student's t-test and Weibull's analysis. The thickness influenced the FR of bilayer crowns. The FR was higher in the TF2 than in the TF1 group. The TF2 group presented the highest characteristic strength compared to the group TF1. The predominant type of failure was delamination. The FEA showed higher stress concentrations below the loading application point at the veneering cement interface in the 1-mm-thick model. The bilayer crowns manufactured using the approach of 2mm of veneering ceramic promoted higher FR compared to the group with 1mm veneering ceramic. Also, the FEA showed that the veneer ceramic thickness has an effect on stress distribution in zirconia-based bilayer crowns.


Resumo Na RLT (Rapid Layer Technology), a cerâmica de cobertura e infraestrutura são fabricados pelo Computer-Aided Design / Computer-Aided Manufacturing (CAD / CAM) e cimentados para obter a restauração. Este estudo teve como objetivo avaliar o efeito da espessura da cerâmica de cobertura fabricada pela técnica RLT na resistência à fratura (RF) de coroas bilaminadas com infraestrutura de zircônia. Vinte infraestruturas de zircônia e vinte coroas posteriores feldspáticas com duas espessuras oclusais da cerâmica de cobertura (1mm = TF1; 2mm = TF2) foram fabricadas usando o sistema CAD / CAM. Os espécimes foram cimentados em preparos de resina epóxi com cimento resinoso dual e ciclados mecanicamente (200N e 4,5×105 Pa, 37° C, 2×106 ciclos, 3Hz). O teste de RF foi realizado (10kN, 0,5mm / min) e, posteriormente, os espécimes foram analisados em estereomicroscópio. Para a análise de tensão (análise de elementos finitos, FEA), uma carga de 10kN foi aplicada igual ao teste in vitro, e a tensão principal foi avaliada. Os dados de RF foram analisados pelo teste t de Student e análise de Weibull. A espessura mostrou forte influência na RF das coroas bilaminadas. A RF foi maior em TF2 do que no grupo TF1. O grupo TF2 apresentou a maior resistência característica em relação ao grupo TF1. O tipo de falha predominante foi a delaminação. O FEA mostrou maiores concentrações de tensões abaixo do ponto de aplicação da carga, na interface cimento e cerâmica de cobertura no modelo de coroa de 1 mm de espessura. As coroas de bilaminadas confeccionadas com 2 mm de cerâmica de cobertura promoveram maior RF em comparação ao grupo com cerâmica de cobertura de 1 mm. Além disso, a FEA mostrou que a espessura da cerâmica de cobertura tem um efeito na distribuição de tensões em coroas bilaminadas à base de zircônia.


Assuntos
Humanos , Porcelana Dentária , Facetas Dentárias , Tecnologia , Zircônio , Teste de Materiais , Cerâmica , Desenho Assistido por Computador , Falha de Restauração Dentária , Coroas , Análise do Estresse Dentário
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...