Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros











Filtros aplicados
Intervalo de ano de publicação
1.
Braz. j. oral sci ; 22: e231702, Jan.-Dec. 2023. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1509504

RESUMO

Aim: Bimaxillary protrusion is a common condition observed irrespective of race and ethnicity and is a chief concern for patients who seek orthodontic treatment. The aim of this study was to compare and evaluate changes in soft tissue structures and incisor positions in class I bimaxillary protrusion subjects undergoing orthodontic therapy when friction and frictionless mechanics were used. Methods: Two groups with a total of 40 patients aged 18­30 years diagnosed with class I bimaxillary protrusion treated by extracting first premolars were considered for this study. Patients treated with friction mechanics were included in Group 1 and those treated with frictionless mechanics in Group 2. The digital lateral cephalograms were calibrated and analyzed using Nemoceph software. Selected landmarks were marked on pre- and post-treatment cephalograms and assessed for intra- and inter-group soft tissue and incisor position changes. Student's t-test was used to analyze the collected data using SPSS 20 software. Result: Intragroup comparison revealed significant changes in both groups. Inter-group comparison of the selected parameters between groups 1 and 2 showed differences but without any statistical significance, except for the inter-incisal angle. Conclusion: Pre- and post-treatment comparison analysis revealed significant soft tissue changes in both groups. However, the comparison between friction and frictionless mechanics showed no statistically significant changes


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Ortodontia , Extração Dentária , Fricção , Má Oclusão
2.
Rev. odontol. UNESP (Online) ; 48: e20190022, 2019. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1020754

RESUMO

Abstract Introduction The orthodontic movement is directly influenced by the ability of orthodontic wires to slide through brackets and tubes. Therefore, the main concern during orthodontic movement corresponds to the frictional forces generated at the bracket-orthodontic wire interface. Objective This study aimed to evaluate the frictional resistance of esthetic orthodontic wires. Material and method Fifty test brackets were obtained and divided into five groups (n = 10) based on the type of rectangular orthodontic wire, as follows: conventional metallic wire (Morelli, Brazil) (G1, control group) and esthetic wires (G2, Ortho Organizer; G3, Tecnident; G4, Trianeiro; and G5, TP Orthodontics). The following materials and conditions were used: 0.019 x 0.025-inch wires, ceramic brackets with edgewise prescription, torque and/or angulation of 0°, and 0.022 x 0.028-inch slots. The specimens were tested for their tensile strength using an Instron universal test machine at a speed of 1.0 mm / min and a load cell of 500N. The tensile strength data were analyzed by one-way analysis of variance (ANOVA) followed by Tukey's post-hoc test, with a 5% significance level. Result The frictional resistance (N) of the metallic orthodontic wire (8.07 ± 0.43) was significantly higher than that of the esthetic wires: Ortho Organizer (4.01 ± 0.25), Tecnident (3.87 ± 0.31), Trianeiro (4.47 ± 0.26) and TP Orthodontics (4.49 ± 0.30) (p <0.05), with no significant difference between them (p> 0.05). Conclusion To conclude, the esthetic orthodontic wires tested herein showed less frictional resistance as compared to the conventional metallic wire.


Resumo Introdução O movimento ortodôntico bem sucedido está diretamente relacionado com a capacidade de os fios ortodônticos deslizarem sobre os bráquetes e tubos ortodônticos. Portanto, durante a movimentação ortodôntica a principal preocupação está diretamente ligada a fricção entre o suporte e o fio. Objetivo O objetivo deste estudo foi avaliar a influência de fios ortodônticos estéticos na resistência ao atrito. Material e método Foram utilizados 50 bráquetes-teste divididos em 5 grupos, de acordo com o fio retangular (n=10): G1 - grupo controle: fio metálico convencional (Morelli, Brasil) e fios estéticos (G2 - Ortho Organizer; G3 - Tecnident; G4 - Trianeiro; e, G5 - TP Orthodontics). Todos os fios apresentavam 0,019 x 0,025 polegadas e o bráquete era cerâmico, prescrição Edgewis e, torque e/ou angulação 0° e, canaleta 0,022 x 0,028 polegadas. O teste de resistência ao atrito sob força de tração foi realizado em uma máquina de ensaio universal Instron à velocidade de 1,0 mm/min e célula de carga de 500N. Os dados de resistência ao atrito foram submetidos à análise de variância (ANOVA) um fator e ao Teste de Tukey com nível de significância de 5%. Resultado O atrito (N) do fio metálico (8,07±0,43) foi significativamente maior que os fios ortodônticos estéticos: Ortho Organizer (4,01±0,25), Tecnident (3,871±0,31), Trident (4,47±0,26) e, TP (4,49±0,30) (p<0,05). Nenhuma diferença estatisticamente significativa foi observada entre os fios estéticos (p>0,05). Conclusão Conclui-se que os fios ortodônticos estéticos apresentam menor resistência ao atrito quando comparado ao fio metálico.


Assuntos
Fios Ortodônticos , Resistência à Tração , Fricção , Ortodontia , Braquetes Ortodônticos , Porcelana Dentária
3.
J. appl. oral sci ; 26: e20170220, 2018. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-893730

RESUMO

Abstract Coated archwires and ceramic brackets have been developed to improve facial esthetics during orthodontic treatment. However, their mechanical behavior has been shown to be different from metallic archwires and brackets. Therefore, the aim of this study was to compare the deflection forces in coated nickel-titanium (NiTi) and esthetic archwires combined with ceramic brackets. Material and Methods Non-coated NiTi (NC), rhodium coated NiTi (RC), teflon coated NiTi (TC), epoxy coated NiTi (EC), fiber-reinforced polymer (FRP), and the three different conventional brackets metal-insert polycrystalline ceramic (MI-PC), polycrystalline ceramic (PC) and monocrystalline ceramic (MC) were used. The specimens were set up on a clinical simulation device and evaluated in a Universal Testing Machine (Instron). An acrylic device, representative of the right maxillary central incisor was buccolingually activated and the unloading forces generated were recorded at 3, 2, 1 and 0.5 mm. The speed of the testing machine was 2 mm/min. ANOVA and Tukey tests were used to compare the different archwires and brackets. Results The brackets presented the following decreasing force ranking: monocrystalline, polycrystalline and polycrystalline metal-insert. The decreasing force ranking of the archwires was: rhodium coated NiTi (RC), non-coated NiTi (NC), teflon coated NiTi (TC), epoxy coated NiTi (EC) and fiber-reinforced polymer (FRP). At 3 mm of unloading the FRP archwire had a plastic deformation and produced an extremely low force in 2; 1 and 0.5 mm of unloading. Conclusion Combinations of the evaluated archwires and brackets will produce a force ranking proportional to the combination of their individual force rankings.


Assuntos
Fios Ortodônticos , Titânio/química , Cerâmica/química , Braquetes Ortodônticos , Desenho de Aparelho Ortodôntico/métodos , Materiais Revestidos Biocompatíveis/química , Níquel/química , Valores de Referência , Propriedades de Superfície , Teste de Materiais , Reprodutibilidade dos Testes , Análise de Variância , Fricção , Estatísticas não Paramétricas , Estética Dentária , Fenômenos Mecânicos
4.
J. appl. oral sci ; 24(5): 496-502, Sept.-Oct. 2016. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-797980

RESUMO

ABSTRACT Objective: The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires placed in different types of brackets: metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating, by assessing strength values variation according to gradual increase in wire diameter and deflection and comparing different combinations in the different deflections. Material and Methods: Specimens were set in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using the ISO 15841 protocol. Data were subjected to One-way ANOVA, followed by Tukey tests (p<0.05). Results: Self-ligating brackets presented the most similar behavior to each other. For conventional brackets there was no consistent behavior for any of the deflections studied. Conclusions: Self-ligating brackets presented the most consistent and predictable results while conventional brackets, as esthetic brackets, showed very different patterns of forces. Self-ligating brackets showed higher strength in all deflections when compared with the others, in 0.020-inch wires.


Assuntos
Fios Ortodônticos , Braquetes Ortodônticos , Ligas/química , Cimento de Policarboxilato/química , Valores de Referência , Titânio/química , Teste de Materiais , Análise de Variância , Desenho de Aparelho Ortodôntico , Fricção , Estatísticas não Paramétricas , Elasticidade , Níquel/química
5.
Roplac ; 4(1): 15-22, jan. 2014. tab
Artigo em Português | BBO - Odontologia | ID: biblio-858915

RESUMO

Este artigo teve por finalidade fazer um estudo comparativo entre os aparelhos ortodônticos convencionais eautoligados, suprindo os profissionais da área com informações que lhes permitam decidir qual modelo utilizarem cada caso clínico. O artigo se desenvolveu a partir da controvérsia que se criou quanto à eficácia e àeficiência dos tratamentos ortodônticos realizados com aparelhos autoligados, quando comparados aostratamentos com os aparelhos convencionais. Tal controvérsia refere-se aos aspectos da eficiência, do confortoe da relação custo-benefício de cada um desses tipos de aparelhos. Assim, este artigo buscou analisarcriticamente, à luz da literatura científica atual, os aspectos positivos e negativos da utilização de cada umdesses aparelhos, bem como sua adequada indicação aos casos clínicos. O tipo metodológico empregado foi apesquisa aplicada, com método hipotético-dedutivo, abordagem quantitativa, objetivo exploratório, eprocedimento de levantamento bibliográfico e documental. Por fim, o trabalho conclui que cada tipo deaparelho ortodôntico tem uma indicação específica, a depender das necessidades pessoais e clínicas de cadapaciente e do sistema de cobrança do profissional


The aim of this article was to compare conventional and self-ligating orthodontic appliances, providingprofessionals of this area information to help them decide which system to use in each clinical case. The articlewas developed from the controversy created about the efficiency and the effectiveness of the orthodontictreatments performed with self-ligating appliances when compared to the treatment with conventionalappliances. Such controversy refers to the aspects of efficiency, comfort and cost-effectiveness of each of thesesystems. Thus, this article aimed to critically analyze, in the light of current scientific literature, the positive andnegative aspects of the utilization and the indication of each orthodontic appliance type in the clinical cases.The method type used was the applied research, with hypothetical-deductive method, quantitative approach,with exploratory objective and bibliographic listing procedure and documentary. We concluded that each typeof orthodontic appliance has a specific indication, depending on the clinical and personal necessities of eachpatient and of the professional billing system


Assuntos
Aparelhos Ortodônticos , Braquetes Ortodônticos , Fricção , Técnicas de Movimentação Dentária , Ortodontia , Brasil
6.
Rev. odontol. UNESP (Online) ; 45(2): 71-77, mar.-abr. 2016. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-780070

RESUMO

Introduction: The Barbosa Versatile bracket design may provide lower frictional force and greater sliding. However, no in vitro studies have shown its sliding mechanisms and frictional resistance, particularly in comparison with other self-ligating or conventional brackets. Objective: To compare the frictional resistance among self-ligating brackets (EasyClip/ Aditek, Damon MX/ Ormco and In Ovation R/ GAC); conventional brackets (Balance Roth/ GAC, and Roth Monobloc/ Morelli); and Barbosa Versatile bracket (Barbosa Versatile/ GAC) with different angles and arch wires. Material and method: Brackets were tested with the 0.014", 0.018", 0.019"×0.025" and 0.021"×0.025" stainless steel wires, with 0, 5, 10, 15 and 20 degree angulations. Tying was performed with elastomeric ligature for conventional and Barbosa Versatile brackets, or with a built-in clip system of the self-ligating brackets. A universal testing machine was used to obtain sliding strength and friction value readouts between brackets and wires. Result: Three-way factorial ANOVA 4×5×6 (brackets × angulation × wire) and Tukey tests showed statistically significant differences for all factors and all interactions (p< 0.0001). Static frictional resistance showed a lower rate for Barbosa Versatile bracket and higher rates for Roth Monobloc and Balance brackets. Conclusion: The lowest frictional resistance was obtained with the Barbosa Versatile bracket and self-ligating brackets in comparison with the conventional type. Increasing the diameter of the wires increased the frictional resistance. Smaller angles produced less frictional resistance.


Introdução: O bráquete Barbosa Versátil apresenta um desenho que pode promover menor resistência friccional e maior deslize. No entanto, nenhum estudo in vitro avaliou seu mecanismo de deslize e resistência ao atrito, mesmo quando comparado com outros bráquetes autoligados ou convencionais. Objetivo: Comparar a resistência ao atrito entre bráquetes autoligados (EasyClip/ Aditek, Damon MX/ Ormco e In Ovation R/ GAC), convencionais (Balance Roth/ GAC, and Roth Monobloco/ Morelli) e o bráquete Barbosa Versátil (Barbosa Versatile/ GAC) com diferentes angulações e fios. Material e método: Os bráquetes foram avaliados com fios de aço inox 0.014", 0.018", 0.019"×0.025" e 0.021"×0.025", com angulações de 0, 5, 10, 15 e 20 graus. Amarrias foram realizadas com ligaduras elastoméricas para os bráquetes convencionais e para o Barbosa Versátil, enquanto que se utilizou o sistema de fechamento próprio para os bráquetes autoligados. A máquina de teste universal foi utilizada para as avaliações de resistência ao atrito entre os bráquetes e fios. Resultado: ANOVA em esquema fatorial 4 × 5 × 6 (bráquetes × angulação × fios) e o teste de Tukey mostraram que houve diferenças significativas para todos os fatores e interações (p< 0,0001). Houve menor resistência ao atrito para o bráquete Barbosa Versátil e maior para os bráquetes Roth Monobloco e Balance. Conclusão: Menor resistência ao atrito foi obtida com o bráquete Barbosa Versátil e com os autoligados em comparação com os bráquetes convencionais. O aumento do diâmetro dos fios aumenta a resistência ao atrito. Menores angulações promovem menor resistência ao atrito.


Assuntos
Fios Ortodônticos , Técnicas In Vitro , Análise de Variância , Braquetes Ortodônticos , Fricção
8.
Ortho Sci., Orthod. sci. pract ; 8(29): 30-37, 2015. ilus, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-751134

RESUMO

O objetivo do presente trabalho foi comparar a força máxima, força de atrito estática e dinâmica existente entre bráquetes de aço inoxidável autoligados passivos da marca EasyClip® (Aditek®), bráquetes de aço inoxidável convencionais Morelli® (Dental Morelli®) ligados com ligaduras elastoméricas convencionais (Dental Morelli®) e com ligaduras elastoméricas não convencionais com desenhos “8” e “88” (Tecnident®). Foi utilizado um dispositivo que permite a movimentação de deslize do fio (aço inoxidável 0,019 X 0,025 polegadas - Morelli®) de forma perpendicular aos slots dos bráquetes alinhados, sem nenhuma possível interferência externa. Uma máquina de testes universal (EMIC DL2000) foi utilizada para o tracionamento dos fios e transformação em dados computadorizados. Esses dados foram transformados e submetidos aos testes de Kolmogorov & Smirnov, e ao teste de Bartlett, depois submetidos às análises não paramétricas Kruskal-Wallis e SNK. Nesse estudo, bráquetes autoligados e bráquetes convencionais com elásticos não convencionais “8” e “88” reduzem o atrito na mecânica de deslize em relação aos módulos elastoméricos convencionais (P<.05).


The aim of the present work was to compare maximum force, static and dynamic friction forces between three different types of brackets: passive stainless steel self-ligating brackets from EasyClip® (Aditek®), conventional Morelli® stainless steel brackets (Dental Morelli®) ligated with conventional elastometric ligatures (Dental Morelli®), and with nonconventional elastomeric ligatures “8” and“88” (Tecnident®). A device that allows the slippage of the wire (stainless steel 0.019 X 0.025 inches - Morelli®) perpendicular to the slots of the aligned brackets with no external interference. A universal testing machine (EMIC DL2000) was used to traction the wire and convert it intocomputerized data. These data were submitted to Kolmogorov & Smirnov tests and to Bartlett test, and then to Nonparametric Tests-Kruskal-Wallis and SNK tests. In the present study it was observed that selfligated brackets and conventional brackets with nonconventional “8” and “88” elastics reduce the friction of sliding mechanics when compared to conventional elastometric modules (P<.05).


Assuntos
Fricção , Técnicas de Movimentação Dentária , Braquetes Ortodônticos , Ortodontia
9.
J. appl. oral sci ; 22(3): 194-203, May-Jun/2014. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-711718

RESUMO

Objective: The aim of this article was to assess how intraoral biodegradation influenced the surface characteristics and friction levels of metallic brackets used during 12 and 24 months of orthodontic treatment and also to compare the static friction generated in these brackets with four different methods of the ligation of orthodontic wires. Material and Methods: Seventy premolar brackets as received from the manufacturer and 224 brackets that were used in previous orthodontic treatments were evaluated in this experiment. The surface morphology and the composition of the deposits found in the brackets were evaluated with rugosimetry, scanning electron microscopy, and energy dispersive X-ray spectroscopy. Friction was analyzed by applying tensile tests simulating sliding mechanics with a 0.019x0.025" steel wire. The static friction levels produced by the following ligation methods were evaluated: loosely attached steel ligature around all four bracket wings, steel ligature attached to only two wings, conventional elastomeric ligation around all 4 bracket wings, and non-conventional Slide® elastomeric ligature. Results: The results demonstrated the presence of biodegradation effects such as corrosion pits, plastic deformation, cracks, and material deposits. The main chemical elements found on these deposits were Carbon and Oxygen. The maximum friction produced by each ligation method changed according to the time of intraoral use. The steel ligature loosely attached to all four bracket wings produced the lowest friction levels in the new brackets. The conventional elastic ligatures generated the highest friction levels. The metallic brackets underwent significant degradation during orthodontic treatment, showing an increase in surface roughness and the deposit of chemical elements on the surface. Conclusion: The levels of static friction decreased with use. The non-conventional elastic ligatures were the best alternative to ...


Assuntos
Humanos , Adulto , Análise de Falha de Equipamento/métodos , Fricção , Desenho de Aparelho Ortodôntico , Braquetes Ortodônticos , Fios Ortodônticos , Análise de Variância , Elastômeros/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Espectrometria por Raios X , Aço Inoxidável/química , Estatísticas não Paramétricas , Propriedades de Superfície , Fatores de Tempo
10.
J. appl. oral sci ; 22(3): 228-234, May-Jun/2014. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-711710

RESUMO

Objective: To compare the influence of archwire material (NiTi, beta-Ti and stainless steel) and brackets design (self-ligating and conventional) on the frictional force resistance. Material and Methods: Two types of brackets (self-ligating brackets - Smartclip, 3M/Unitek - and conventional brackets - Gemini, 3M/Unitek) with three (0, 5, and 10 degrees) slot angulation attached with elastomeric ligatures (TP Orthodontics) were tested. All brackets were tested with archwire 0.019"x0.025" nickel-titanium, beta-titanium, and stainless steel (Unitek/3M). The mechanical testing was performed with a universal testing machine eMIC DL 10000 (eMIC Co, Brazil). The wires were pulled from the bracket slots at a cross-head speed of 3 mm/min until 2 mm displacement. Results: Self-ligating brackets produced significantly lower friction values compared with those of conventional brackets. Frictional force resistance values were directly proportional to the increase in the bracket/ wire angulation. With regard to conventional brackets, stainless steel wires had the lowest friction force values, followed by nickel-titanium and beta-titanium ones. With regard to self-ligating brackets, the nickel-titanium wires had the lowest friction values, significantly lower than those of other materials. Conclusion: even at different angulations, the self-ligating brackets showed significantly lower friction force values than the conventional brackets. Combined with nickel-titanium wires, the self-ligating brackets exhibit much lower friction, possibly due to the contact between nickel-titanium clips and wires of the same material. .


Assuntos
Fricção , Níquel/química , Desenho de Aparelho Ortodôntico , Braquetes Ortodônticos , Aço Inoxidável/química , Titânio/química , Ligas Dentárias/química , Teste de Materiais , Fios Ortodônticos , Valores de Referência , Propriedades de Superfície
11.
Ortodontia ; 47(2): 163-170, mar.-abr. 2014. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-715791

RESUMO

O uso dos braquetes autoligados tem sido cada vez mais difundido entre os ortodontistas de todo o mundo por apresentar muitas vantagens, como baixa fricção e níveis baixos de forças. O presente trabalho descreveu o tratamento ortodôntico de um paciente de 17 anos e um mês de idade, com apinhamento superior e inferior, e desvio de linha média dentária, cujos resultados demonstraram a efetividade do tratamento realizado com o sistema autoligado, otimizado por meio do uso estratégico dos stops.


The use of self-ligating brackets has been increasingly widespread among orthodontists from around the world by presenting many advantages such as low friction and low levels of forces. This paper describes the orthodontic treatment of a patient of 17 years and 1 month old, with upper and lower crowding and dental midline deviation, which results demonstrate the effectiveness of the treatment with the selfligating system, optimized by the strategic use of the stops.


Assuntos
Humanos , Masculino , Adolescente , Fricção , Aparelhos Ortodônticos , Braquetes Ortodônticos
12.
J. appl. oral sci ; 21(6): 554-559, Nov-Dec/2013. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-697820

RESUMO

The relationship between orthodontic force and friction produced from an archwire and brackets affects the sliding of the wire in the leveling stage. Objective: The purpose of this study was to evaluate the relationship between force and friction in a small esthetic nickel-titanium (Ni-Ti) wire. Material and Methods: Five esthetic wires (three coated and two plated) and two small, plain Ni-Ti wires (0.012 and 0.014 inches) were used. We performed a three-point bending test according to ISO 15841 and the drawing test with a dental arch model designed with upper linguoversion of the lateral incisor in the arch (displacements of 0.5, 1.0, 2.0 and 3.0 mm), and evaluated the relationship between them. Results: Unloading bending forces of all wires at displacements of less than 1.0 mm were larger than friction forces, but all friction forces at displacements exceeding 2.0 mm were larger than unloading bending forces. The arch likely expands when displacement from the proximal brackets exceeds 1.0 mm. The friction force of a martensite 0.014-inch Ni-Ti wire was significantly greater than those of the other esthetic and austenitic wires. Conclusions: A wire with the smallest possible friction force should be used in cases with more than 1.0 mm displacement. .


Assuntos
Fricção , Níquel , Desenho de Aparelho Ortodôntico , Fios Ortodônticos , Titânio , Força de Mordida , Arco Dental , Teste de Materiais , Modelos Anatômicos , Braquetes Ortodônticos , Valores de Referência , Reprodutibilidade dos Testes , Propriedades de Superfície , Resistência à Tração
13.
Rev. Clín. Ortod. Dent. Press ; 12(3): 102-111, jun.-jul. 2013. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-707653

RESUMO

Introdução: avaliar, in vitro, a rugosidade, a morfologia e os níveis de atrito oferecidos pelos braquetes antes e após a escovação com diferentes cremes dentais. Métodos: cento e dez braquetes metálicos foram aleatoriamente distribuídos em 11 grupos: 1 grupo controle (saliva artificial) e 10 grupos experimentais (n = 10). Após colagem dos braquetes em dispositivo específico, esses foram submetidos a três escovações diárias com diferentes tipos de cremes dentais durante um período de 28 dias. Os cremes dentais avaliados foram: Close Up Ação Profunda, Close Up Triple, Colgate Luminous White, Colgate Tripla Ação, Oral B Pró Saúde, Oral B Pró-Saúde Whiteness, Sensodine Fresh, Sensodine Original, Sorriso Fresh Plus e Sorriso Original. Entre as escovações, os braquetes foram lavados em água corrente e acondicionados em recipiente contendo saliva artificial e mantidos em estufa à temperatura de 37ºC. Para a avaliação da rugosidade foi utilizada microscopia eletrônica de varredura. As imagens obtidas foram avaliadas quantitativamente por meio de análise de imagem em histogramas. Os níveis de atrito foram medidos por uma máquina de dobramento. Os dados foram comparados estatisticamente por meio da ANOVA, utilizando o teste t de Student. Resultados: observou-se presença de ranhuras, sobretudo no grupo Colgate Luminous White. Houve diferenças estatísticas nos níveis de atrito entre os grupos Close Up Ação Profunda, Close Up Triple e Colgate Luminous White. Conclusão: o creme dental Colgate Luminous White apresentou maior rugosidade de superfície e maior nível de atrito; a menor rugosidade foi observada nos grupos Close Up Ação Profunda e Sorriso Fresh Plus.


Assuntos
Braquetes Ortodônticos , Cremes Dentais/efeitos adversos , Fricção , Técnicas In Vitro , Teste de Materiais
14.
Dent. press implantol ; 7(2): 81-90, Apr.-June 2013. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-714115

RESUMO

Introdução: técnicas de enxerto de tecido conjuntivo são amplamente empregadas durante e previamente a colocação e reabilitação de implantes para a obtenção de resultados estéticos satisfatórios. Contudo, essas técnicas cirúrgicas não são as únicas opções para a correção de deficiências de volume tecidual. Objetivo: mostrar, por meio de um caso clínico, a extrusão ortodôntica lenta, a incisão semilunar durante a fase de reabertura e a utilização da resina composta fluída para o condicionamento tecidual em três etapas: no pôntico ogival, no cicatrizador de polímero e na coroa provisória sobre implante. Resultados: a extrusão ortodôntica lenta promoveu um melhor nivelamento na altura do colo gengival. A incisão semilunar mostrou-se um procedimento que favorece o deslocamento de tecido mucoso para vestibular e a preservação das papilas adjacentes. A resina composta fluída apresentou-se como um material de fácil manuseio e de bom polimento, o que contribuiu para a obtenção de um perfil transmucoso adequado para a coroa sobre implante. Conclusão: concluímos que, após acompanhamento clínico de um ano, esses procedimentos combinados auxiliam na conquista de resultados peri-implantares estéticos e contribuem para a prática da Implantodontia minimamente invasiva.


Introduction: Connective tissue graft techniques are widely used previously and during the dental implant treatment to obtain satisfactory aesthetic results. However surgical techniques are not the only options for correcting tissue volume deficiencies. The aim of this article is to show, by a clinical case, the prior orthodontic extrusion, the semilunar incision during the implant second surgical stage and the use of composite resin flow for soft tissue conditioning in the ovate pontic, the polymer healing abutment and the provisional crown on the implant. The orthodontic extrusion promoted a better leveling in the gingival collar height. The semilunar incision favored the displacement of the buccal mucosal tissue and the preservation of adjacent papillae. The composite resin flow is a easy handling material and have a good polishing, which contributed to obtain a appropriate transmucosal profile. We concluded, after 1 year of clinical follow-up, that the combined procedures aided to gain aesthetic periimplant results and contributed to thepractice of a minimally invasive implantology.


Assuntos
Humanos , Feminino , Resinas Compostas , Polimento Dentário , Implantação Dentária/métodos , Extrusão Ortodôntica , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Brasil , Fricção , Cicatrização
15.
Braz. j. oral sci ; 12(1): 41-45, jan.-mar. 2013. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-671931

RESUMO

Aim: To evaluate the frictional force between the archwire and orthodontic bracket generated by elastomeric ligatures with polymer coating (Super slick, TP Orthodontics) and conventional ligatures (Morelli) using two types of insertion techniques. Methods: Forty elastomeric ligatures, 20 with polymer coating and 20 conventional, were evaluated. Each type of ligature was separated into two groups (n=10), according to the insertion mode: conventional or crossed (from mesial to distal region crossed in front). To analyze friction, 40 5-cm-long segments of stainless steel orthodontic archwire 0.019" x 0.025" (Morelli) and Edgewise brackets (slot 0.022" x 0.028"; Morelli) were used. Each set (bracket, wire and elastic) was submitted to frictional testing in a universal test machine (Instron 4411) at a crosshead speed of 5 mm/min. Each bracket was moved 5 mm on the wire, with maximum friction and mean friction being recorded by software. Three readouts were taken for each bracket. Data were submitted to two-way ANOVA and Tukey’s test (p<0.05). Results: It was shown that for maximum and mean friction, the polymer-coated ligature did not differ statistically from the conventional type in a dry environment condition. Ligatures placed incrossed mode promoted significantly greater friction than those placed in conventional mode, irrespective of the type of elastomeric ligature. Conclusions: Friction depended on the insertion mode, but not on the type of elastomeric ligature.


Assuntos
Elastômeros , Fricção , Ortodontia/instrumentação
16.
Campinas, SP; s.n; 2012. 57 p. ilus.
Tese em Português | BBO - Odontologia | ID: biblio-866741

RESUMO

O sucesso do movimento ortodôntico ocorre na dependência da mecânica de deslize entre braquetes e fio, a qual é influenciada pelo atrito entre ambos. O objetivo deste estudo foi avaliar o efeito da interposição de diferentes lubrificantes na força de atrito entre fios ortodônticos e braquetes autoligados, ativos e passivos. Os fatores em estudo foram Tipo de Braquete (ativo e passivo) e Condição de Lubrificação (ausente, como controle negativo; saliva natural humana, como controle positivo; água destilada, saliva artificial à base de mucina e saliva artificial à base de carboximetilcelulose). As unidades experimentais foram 50 braquetes autoligados ativo (Quick, Forestadent) e 50 passivos (Damon 3MX, Ormco), em cujos slots deslizou um fio com 0,014” x 0,025” de CuNiTi. Amostras de saliva humana total não estimulada foram coletadas de um único indivíduo, pela manhã, 2 horas após a ingestão de alimentos e realização da escovação dental. As demais salivas foram manipuladas em laboratório. Os braquetes foram aderidos a uma base cilíndrica acoplada a uma máquina de ensaios universal, sendo as amostras braquete/ fio ensaiadas na presença de uma das condições de lubrificação. O ensaio foi realizado oito vezes, a uma velocidade de 3 mm/min. A análise de variância a dois critérios demonstrou que não houve interação significativa entre os fatores em estudo Tipo de Braquete e Condição de Lubrificação (p = 0,324). A força de atrito proporcionada pelos braquetes autoligados passivos foi significativamente inferior àquela observada com a utilização de braquetes ativos (p < 0,001). O teste de Tukey revelou que os valores de força de atrito gerados com o emprego das salivas artificiais não diferiram daqueles verificados para no grupo em que se empregou saliva natural humana. Valores significativamente superiores de força de atrito foram observados nas condições em que se utilizou água destilada ou em que se realizou o ensaio sob atrito seco (lubrificante ausente)...


The success of the orthodontic movement occurs depending on the sliding mechanics between brackets and wire, which is influenced by friction between both. The purpose of this study was to evaluate the effect of interposition of different lubricants on friction between orthodontic wires and active and passive self-ligating brackets. Factors under study were Type of Bracket (active and passive) and Lubricant Condition (absent, as negative control; natural human saliva, as positive control; distilled water, mucin-based artificial saliva and carboxymethylcellulose (CMC)-based artificial saliva). The experimental units were 50 active self-ligating brackets (Quick, Forestadent) and 50 passive (Damon 3MX, Ormco), in which slots slided a 0.014” x 0.025” CuNiTi wire. Samples of unstimulated total human saliva were collected from a single donor, in the morning, 2 hours after food intake and brushing procedure. Artificial salivas were manipulated in laboratory. The brackets were bonded to a cylindrical base attached to a universal testing machine, where the bracket/wire samples were tested in the presence of one of the lubricant condition. Testing was performed eight times, at a 3 mm/min speed. Two-way analysis of variance showed that there was no significant interaction between the Type of Brackets and Lubricant Condition (p = 0.324). Friction provided by the passive self-ligating brackets was significantly lower than that noticed with the active brackets (p < 0.001). Tukey’s test revealed that the friction generated with the application of artificial saliva did not differ from that found in the group tested with natural human saliva. Significantly higher friction was observed as a result of using distilled water or dry friction (no lubricant). In these two conditions friction was equivalent. It was concluded that active brackets produced higher friction compared with the passive counterparts, regardless of the lubricant condition...


Assuntos
Fricção , Braquetes Ortodônticos , Ortodontia
17.
Campinas, SP; s.n; 2012. 80 p. ilus.
Tese em Português | BBO - Odontologia | ID: biblio-866746

RESUMO

Este trabalho verificou o efeito de desafios cariogênicos (DCs) e erosivos (DEs) na degradação de fios ortodônticos fabricados em liga de cobre-níquel-titânio (CuNiTi), por meio da mensuração da rugosidade e de fotomicrografias obtidas em microscópio de força atômica (MFA). Em adição, avaliou-se a força de atrito estabelecida entre braquetes autoligados passivos e os referidos fios após terem sido expostos a DCs e DEs. Sessenta segmentos de fios foram distribuídos em quatro grupos, para serem submetidos a DCs ou DEs, que simularam seu uso clínico por 12 semanas, para serem expostos à saliva artificial ou para integrarem o grupo controle (sem tratamento). Os DCs foram realizados com solução desmineralizante (pH 4,3), empregada em modelos físico-químicos de cárie, sendo que os fios foram a ela expostos por 24 horas, por 21 dias. Para simular condição de alto DE, realizou-se a imersão dos fios em solução de ácido cítrico a 0,05 M (pH 2,3) por 60 minutos diários, também por 21 dias. Os fios foram avaliados quanto a sua rugosidade média, aferida pelo parâmetro Ra, em rugosímetro. A seguir, os fios foram submetidos a ensaios de atrito, realizados em uma máquina de testes universal, operando a uma velocidade de 3 mm/min, utilizando-se braquetes metálicos (Damon 3MX – Ormco). Com finalidade ilustrativa, obtiveram-se imagens em MFA. Os testes de Kruskal Wallis (p = 0,004) e de Dunn demonstraram que os fios de CuNiTi submetidos a DEs apresentaram valores de Ra significativamente superiores àqueles armazenados em saliva artificial, achado substanciado pela MFA. Os fios submetidos a DCs revelaram valores intermediários de Ra, não diferindo dos grupos imersos em saliva artificial ou na solução erosiva. A força de atrito estabelecida entre os fios e braquetes não foi significativamente influenciada pelos DCs ou DEs. Concluiu-se que frente a DEs, a rugosidade superficial do fio ortodôntico de CuNiTi tornou-se superior àquela causada pela saliva artificial...


This study examined the effect of cariogenic (CCs) and erosive challenges (ECs) on degradation of orthodontic wires fabricated in copper-nickel-titanium alloy (Copper NiTi), through roughness measurements and atomic force microscopy photomicrographs (AFM). In addition, friction established between passive self-ligating brackets and the aforementioned wires was evaluated following CCs and ECs. Sixty wires segments were distributed in four groups, to be submitted to CC or EC, that simulated their clinical use for 12 weeks, to be exposed to artificial saliva or to integrate the control group (no treatment). The CCs were performed with demineralizing solution (pH 4.3), used in physico-chemical caries models, in which wires were immersed for 24 hours, for 21 days. To simulate the condition of high EC, wires were stored in 0.05 M citric acid solution (pH 2.3) for 60 minutes daily, for 21 days. Wires were evaluated for average roughness (Ra), in perfilometer. Next, wires were submitted to friction tests, performed in a universal testing machine, at a crosshead speed of 3 mm/min, using metallic brackets (Damon 3MX – Ormco). AFM images were obtained with illustrative purpose. Kruskal-Wallis (p = 0.004) and Dunn tests demonstrated that Copper NiTi wires submitted to ECs presented Ra values significantly higher than those stored in artificial saliva. Such a finding was substantiated by AFM. Wires submitted to CCs revealed intermediate Ra values, not differing from the groups immersed in artificial saliva or erosive solution. Friction established between wires and brackets was not significantly influenced by ECs or CCs. It was concluded that the surface roughness of a Copper NiTi orthodontic wire immersed in ECs was higher than that caused by artificial saliva. There was no correlation between the surface roughness generated by the wire exposure to CCs, ECs or artificial saliva and the friction established between the wire and a passive self-ligating bracket


Assuntos
Corrosão , Fricção , Ortodontia
18.
Ortodontia ; 44(4): 376-380, jul.-ago. 2011.
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-713824

RESUMO

A Ortodontia atual vem sofrendo, há duas décadas, um contínuo processo deadaptação aos novos recursos tecnológicos e às novas técnicas que apareceram com oobjetivo de tornar a terapia ortodôntica cada vez mais rápida, confortável e, sobretudo,eficaz para o ortodontista e para o paciente. Em especial, os aparelhos autoligados, criadosinicialmente com o intuito de tornar mais prática a inserção e a remoção do fio ortodônticoda canaleta do bráquete, hoje, apresentam características essenciais para uma abordagemmais biológica e mais eficiente da movimentação dentária. Sendo assim, este trabalho visouabordar as vantagens do uso desta nova geração de bráquetes em comparação aos sistemasconvencionais, através de uma revisão bibliográfica do tema. Concluiu-se que os sistemasauto ligados apontam como uma grande tendência mundial aos recursos terapêuticos daprática ortodôntica por suas qualidades de redução do tempo total de tratamento, reduçãodo tempo de cadeira, controle de biofilme e bons resultados .


The current Orthodontics comes suffering, has two decades, a continuousprocess of adaptation the new technological resources and the new techniques that hadappeared with the objective to become the orthodontic therapy each faster, comfortable,and over ali, effjcient, for the orthodontic professional and the patient. In special, the selfligatingappliances, created, prior, with intention to become more practical the insertion andremoval the orthodontic wire of the slot of brackets, today, present essential characteristicsto a approach more biological and more etticient of the dental movement. Being thus, thissurvey aims to approach the advantages of the use of this new generation of brackets incomparison to the conventional brackets systems through a bibliographical revision of thetopic. The conclusion was the self-ligating systems put forward as a great world-wide trendto the therapeutical resources of practical the orthodontic one for its qualities of reductionof the total time of treatment, reduction of the chair time, control of bacterial plate andsatisfactory results.


Assuntos
Fricção , Braquetes Ortodônticos , Ortodontia
19.
Rev. Clín. Ortod. Dent. Press ; 10(1): 45-54, fev.-mar. 2011. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-586812

RESUMO

Em estudos feitos por Andrews em americanos e Zanelato e Mada em brasileiros, onde avaliou-se o posicionamento tridimensional de cada dente em indivíduos com oclusão normal natural, com relação à angulação dos caninos superiores, observou-se uma variação de até 24º, oscilando entre -3º e 21º. Se existe esta grande variação em indivíduos que nasceram com a dentição perfeita, como conseguir na técnica Straight Wire uma posição definitiva ideal funcional dos caninos, se na maioria das vezes usa-se uma única prescrição de braquetes com angulação dos caninos definidas pela prescrição? Para encontrar uma posição individual para cada paciente foi desenvolvido uma braquete com características diferentes dos convencionais e que proporciona o controle absoluto da posição final dos caninos, denominado de Barbosa Braquete Versátil, com capacidade de variação de zero até 31º de angulação. Essa versatilidade possibilita encontrar a posição ideal dos caninos para cada paciente. O aumento do slot convencional, tanto em largura como em profundidade (0,030"), leva a uma diminuição da fricção dependendo da forma de amarrá-la. Mesmo com a e existência de uma grande quantidade de outras prescrições com variações na angulação dos caninos, a capacidade de individualização nesta angulação através do Barbosa Braquete Versátil assegura uma posição funcional dos caninos.


Assuntos
Braquetes Ortodônticos , Dente Canino , Fios Ortodônticos , Fricção
20.
Ortho Sci., Orthod. sci. pract ; 4(15): 632-641, 2011. ilus, tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-605613

RESUMO

Os bráquetes autoligáveis tem sido utilizados pelos ortodontistas devido à promessa de redução do atrito com os fios ortodônticos. O presente estudo teve como objetivo comparar a resistência friccional produzida pelos bráquetes autoligáveis Damon 3 (Ormco), SmartClip (3M Unitek) e In-Ovation (GAC) e pelos bráquetes convencionais Victory (3M Unitek) com módulos elásticos e amarrilhos metálicos, considerando fios retangulares de aço inoxidável e de níquel-titânio de diferentes dimensões (.017”x.025”, .019”x.025” e .021”x.025”), bem como avaliar se existe diferença na fricção quando comparados os fios de aço inoxidável e de níquel-titânio testados. Para isso, foram confeccionados corpos de prova com dentes de estoque nos quais foram colados os bráquetes avaliados. Para mensurar a fricção produzida foi utilizada uma máquina universal de ensaio mecânico Instron que realizou a tração dos fios pelas canaletas dos bráquetes. Foram realizadas cinco repetições por bráquete, para cada fio estudado, totalizando 150 testes. Os valores foram comparados utilizando o teste LSD (“least significant difference”) para as comparações múltiplas. Na comparação dos dois tipos de fio foi utilizado o teste t Student para amostras independentes. A partir dos resultados obtidos, concluiu-se haver redução significativa da fricção utilizando os bráquetes autoligáveis Damon 3 e SmartClip quando comparados ao bráquete autoligável In Ovation e ao bráquete convencional com amarrilho e com módulo elástico. Não houve diferença significativa nos valores do atrito entre as diferentes secções de fio nem entre as duas ligas metálicas estudadas.


Self-ligated brackets have being used by the orthodontists with the aim to reduce the frictionwith orthodontic wires. The objective of this study was to compare the frictional resistance produced by Damon 3 (Ormco), SmartClip (3M Unitek) and In-Ovation (GAC) self-ligated brackets and Victory (3M Unitek) conventional bracket with elastomeric modules and metallic ligatures considering stainless steel and Ni-Ti rectangular wires with different dimensions (.017”x.025”, .019”x.025” and .021”x.025”), as well as to compare the friction produced by stainless steel and Ni-Ti wires. Tested brackets were bonded in stock premolars and friction was evaluated by the traction of the wires thought bracket slots in an Instron universal test machine. Five repetitions for each bracket and wire combination were performed in a total of 150 tests. LSD test (least significant difference) was used for multiple comparisons and Student t test for independent samples was used to compare wires. Results showed that there was a significant reduction of friction when Damon 3 and SmartClip self-ligated brackets were compared with In-Ovation self-ligated bracket and conventional bracket with elastomeric modules and metallic ligature. There was no significant difference in friction among the three wire dimensions studied neither when stainless steel and Ni-Ti wires were compared.


Assuntos
Fricção , Braquetes Ortodônticos , Ortodontia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA