Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
2.
J. appl. oral sci ; 27: e20180132, 2019. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-975898

RESUMO

Abstract Bulk-fill composites were introduced in dentistry to accelerate clinical procedures while providing adequate outcomes. Concerns regarding the use of bigger composite increments rely on the polymerization shrinkage and shrinkage stress, which may generate gaps on the adhesive interface and result in a reduced success rate. Objective: To evaluate the polymerization shrinkage stress of different bulk-fill resin composites and their elastic modulus. Materials and Methods: Fourteen specimens were made for each of the nine different resin composites (seven with 12 mm3 and seven with 24 mm3): Surefill SDR flow (SDR), X-tra Base (XB), Filtek Bulk Fill Flowable (FBF), Filtek Z350XT Flow (Z3F); Tetric Evo Ceram Bulk Fill (TBF), X-tra Fil (XF), Filtek Bulk Fill (FBP), Admira Xtra Fusion (ADM) and Filtek Z350 XT (Z3XT). Linear shrinkage stress was evaluated for 300 s with the aid of a linear shrinkage device adapted to a Universal Testing Machine. For each composite group, seven additional specimens (2x2x25 mm) were made and Young's modulus was evaluated with a 3-point bending device adapted in a Universal Testing Machine with 0.5 mm/min crosshead speed and 50 KgF loading cell. Results: For 12 mm3 specimens, three-way ANOVA showed that only SDR and TBF generated lower stress after 20 s. Considering 300 s, TBF, SDR, and XF generated the lowest stress, followed by ADM, FBP, XB, and FBF, which were similar to Z3XT. Z3F generated the highest stress values for all time points. Considering 24 mm3 specimens after 20 s, all bulk fill composites generated lower stress than Z3XT, except XB. After 300 s, SDR, FBP, and ADM generated the lowest stress, followed by TBF and XF. For elastic modulus, one-way ANOVA showed that FBF, SDR, Z3F, and ADM presented the lowest values, followed by XB and TBF. FBP, Z3XT, and XF presented the highest elastic modulus among the evaluated composites. Conclusions: Bulk-fill resin composites presented equal to lower shrinkage stress generation when compared to conventional composites, especially when bigger increments were evaluated. Bulk-fill composites showed a wide range of elastic modulus values, but usually similar to "regular" composites.


Assuntos
Estresse Mecânico , Resinas Compostas/química , Módulo de Elasticidade , Polimerização , Valores de Referência , Siloxanas/química , Propriedades de Superfície , Teste de Materiais , Reprodutibilidade dos Testes , Análise de Variância , Estatísticas não Paramétricas , Análise do Estresse Dentário , Metacrilatos/química
3.
Dental press j. orthod. (Impr.) ; 22(4): 77-85, July-Aug. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-891079

RESUMO

ABSTRACT Introduction: Plasma-polymerized film deposition was created to modify metallic orthodontic brackets surface properties in order to inhibit bacterial adhesion. Methods: Hexamethyldisiloxane (HMDSO) polymer films were deposited on conventional (n = 10) and self-ligating (n = 10) stainless steel orthodontic brackets using the Plasma-Enhanced Chemical Vapor Deposition (PECVD) radio frequency technique. The samples were divided into two groups according to the kind of bracket and two subgroups after surface treatment. Scanning Electron Microscopy (SEM) analysis was performed to assess the presence of bacterial adhesion over samples surfaces (slot and wings region) and film layer integrity. Surface roughness was assessed by Confocal Interferometry (CI) and surface wettability, by goniometry. For bacterial adhesion analysis, samples were exposed for 72 hours to a Streptococcus mutans solution for biofilm formation. The values obtained for surface roughness were analyzed using the Mann-Whitney test while biofilm adhesion were assessed by Kruskal-Wallis and SNK test. Results: Significant statistical differences (p< 0.05) for surface roughness and bacterial adhesion reduction were observed on conventional brackets after surface treatment and between conventional and self-ligating brackets; no significant statistical differences were observed between self-ligating groups (p> 0.05). Conclusion: Plasma-polymerized film deposition was only effective on reducing surface roughness and bacterial adhesion in conventional brackets. It was also noted that conventional brackets showed lower biofilm adhesion than self-ligating brackets despite the absence of film.


RESUMO Introdução: a deposição de filme de polímero a plasma foi criada para modificar as propriedades de superfície dos braquetes ortodônticos metálicos, com o intuito de inibir a adesão bacteriana. Métodos: filmes finos de polímero de hexametildisiloxano (HMDSO) foram depositados em braquetes ortodônticos de aço inoxidável convencionais (n = 10) e autoligáveis (n = 10), utilizando a técnica de radiofrequência PECVD (Plasma-Enhanced Chemical Vapor Deposition). As amostras foram divididas em dois grupos, de acordo com o tipo de braquete, e dois subgrupos após o tratamento de superfície. A microscopia eletrônica de varredura (MEV) foi realizada para avaliar a presença de adesão bacteriana sobre as superfícies das amostras (região de ranhura horizontal e aletas) e a integridade da camada de filme. A Interferometria Confocal (CI) avaliou a rugosidade, e a molhabilidade superficial foi avaliada por goniometria. Para análise de adesão bacteriana, as amostras foram expostas durante 72 horas a uma solução de Streptococcus mutans, para formação de biofilme. Os valores obtidos para a rugosidade da superfície foram analisados pelo teste de Mann-Whitney, enquanto a adesão do biofilme foi avaliada pelos testes de Kruskal-Wallis e SNK. Resultados: observaram-se diferenças estatisticamente significativas (p <0,05) para a rugosidade superficial e redução da adesão bacteriana em braquetes convencionais após o tratamento da superfície, e entre braquetes convencionais e autoligáveis. Não foram observadas diferenças estatísticas significativas entre os grupos autoligáveis (p> 0,05). Conclusão: a deposição de polímero a plasma só foi efetiva na redução da rugosidade superficial e adesão bacteriana em braquetes convencionais. Observou-se, também, que os braquetes convencionais apresentaram menor adesão ao biofilme do que os braquetes autoligáveis, apesar da ausência de filme.


Assuntos
Siloxanas/farmacologia , Streptococcus mutans/efeitos dos fármacos , Streptococcus mutans/fisiologia , Aderência Bacteriana/efeitos dos fármacos , Braquetes Ortodônticos/microbiologia , Biofilmes/efeitos dos fármacos , Plasma , Streptococcus mutans/isolamento & purificação , Propriedades de Superfície , Desenho de Aparelho Ortodôntico , Polimerização
4.
Acta odontol. latinoam ; 30(1): 13-18, 2017. tab
Artigo em Inglês | LILACS | ID: biblio-907402

RESUMO

This study compared the surface detail reproduction anddimensional accuracy of molds after disinfection using 2% sodium hypochlorite, 2% chlorhexidine digluconate or 0.2% peracetic acid to those of molds that were not disinfected, forfour elastomeric impression materials: polysulfide (Light Bodied Permlastic), polyether (Impregum Soft), polydimethylsiloxane(Oranwash L) and polyvinylsiloxane (Aquasil Ultra LV). Themolds were prepared on a matrix by applying pressure, using aperforated metal tray. The molds were removed followingpolymerization and either disinfected (by soaking in one of thesolutions for 15 minutes) or not disinfected. The samples werethus divided into 16 groups (n=5). Surface detail reproductionand dimensional accuracy were evaluated using opticalmicroscopy to assess the 20 ­µm line over its entire 25 mm length. The dimensional accuracy results (%) were subjectedto analysis of variance (ANOVA) and the means were comparedby Tukey’s test (α=5%). The 20 ­µm line was completelyreproduced by all elastomeric impression materials, regardlessof disinfection procedure. There was no significant difference between the control group and molds disinfected with peraceticacid for the elastomeric materials Impregum Soft (polyether)and Aquasil Ultra LV (polyvinylsiloxane). The high­leveldisinfectant peracetic acid would be the choice material for disinfection.


Este estudo comparou a reprodução de detalhes da superfície e estabilidade dimensional de moldes obtidos após desinfecção utilizando hipoclorito de sódio 2%, digluconato de clorexidina 2%, ou ácido peracético 0,2% a moldes que não foram desinfetados com quatro elastômeros: polissulfeto (Light Bodied Permlastic), polieter (Impregum Soft), silicona reação porcondensação (Oranwash L) e silicona reação por adição (Aquasil Ultra LV). Os moldes foram preparados sobre matriz conten dolinhas de 20, 50 e 75 µm realizado sob pressão com moldeirade metal perfurada. Os moldes foram removidos após a polimerização e desinfetados (utilizando uma das soluções porimersão, armazenados em frascos fechados durante 15 minutos)ou não desinfetados. Assim, as amostras foram divididas em 16grupos (n=5). A reprodução detalhes da superfície e a precisão dimensional foram avaliadas usando microscopia óptica na linha 20 µm com 25 mm de comprimento, de acordo com a norma ISO 4823. Os resultados de precisão dimensional (%) foram submetidos à análise de variância (A NOVA) e as médias comparadas pelo teste de Tukey com 5% de nível de significância. A linha de 20 µm foi completamente reproduzida por todos os elastômeros, independentemente do processo de desinfecção. Não houve diferença estatisticamente significativa entre o grupo controle e moldes desinfetados com acido peracético para os elastômeros Impregum Soft (polieter) e Aquasil Ultra LV (siliconareação por adição). O desinfetante de alto nível ácido peracético seria o material de escolha para a desinfecção.


Assuntos
Humanos , Materiais para Moldagem Odontológica , Modelos Dentários , Desinfetantes de Equipamento Odontológico/química , Propriedades de Superfície , Análise de Variância , Clorexidina/química , Precisão da Medição Dimensional , Ácido Edético/química , Elastômeros/classificação , Microscopia/métodos , Interpretação Estatística de Dados , Siloxanas/classificação , Hipoclorito de Sódio/química , Sulfetos/classificação
5.
Braz. oral res. (Online) ; 30(1): e113, 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-951952

RESUMO

Abstract The objective of this study was to evaluate the marginal and internal fit of zirconia copings obtained with different digital scanning methods. A human mandibular first molar was set in a typodont with its adjacent and antagonist teeth and prepared for an all-ceramic crown. Digital impressions were made using an intraoral scanner (3Shape). Polyvinyl siloxane impressions and Type IV gypsum models were also obtained and scanned with a benchtop laboratory scanner (3Shape D700). Ten zirconia copings were fabricated for each group using CAD-CAM technology. The marginal and internal fit of the zirconia copings was assessed by the silicone replica technique. Four sections of each replica were obtained, and each section was evaluated at four points: marginal gap (MG), axial wall (AW), axio-occlusal edge (AO) and centro-occlusal wall (CO), using an image analyzing software. The data were submitted to one-way ANOVA and Tukey's test (α = 0.05). They showed statistically significant differences for MG, AO and CO. Regarding MG, intraoral scanning showed lower gap values, whereas gypsum model scanning showed higher gap values. Regarding AO and CO, intraoral digital scanning showed lower gap values. Polyvinyl siloxane impression scanning and gypsum model scanning showed higher gap values and were statistically similar. It can be concluded that intraoral digital scanning provided a lower mean gap value, in comparison with conventional impressions and gypsum casts scanned with a standard benchtop laboratory scanner.


Assuntos
Humanos , Zircônio/química , Técnica de Moldagem Odontológica/instrumentação , Adaptação Marginal Dentária , Polivinil/química , Valores de Referência , Siloxanas/química , Processamento de Imagem Assistida por Computador/instrumentação , Teste de Materiais , Sulfato de Cálcio/química , Reprodutibilidade dos Testes , Análise de Variância , Técnica de Fundição Odontológica , Planejamento de Prótese Dentária , Desenho Assistido por Computador , Materiais para Moldagem Odontológica/química
6.
Braz. oral res. (Online) ; 30(1): e36, 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-951975

RESUMO

Abstract The aim of the study was to evaluate the effect of the incorporation of different fillers on an experimental vinyl polysiloxane (VPS) at two different concentrations, 20% and 40%. Different fillers were added to an experimental VPS. The study was developed in two stages: (i) incorporation of fillers in different concentrations: (a) 20 wt% fillers, and (b) 40 wt%. The fillers were added to experimental VPS and mixed with a speed mixer; (ii) characterization of experimental VPS; after the base paste and catalyst paste were mixed, the experimental VPS was used to make specimens specifically for each test, which were stored at 23°C for 24 hours. The tests were designed according to the specific standardization for the analysis of tensile strength, detail reproduction, Shore A hardness, and elastic recovery. For analysis of filler size pattern, scanning electron microscopy at 1500× magnification was used. The aerosil OX-50 40% (AE), and pure aluminum hydroxide 40% (PAH) groups presented the highest tensile strength and Shore A hardness values. However, those were the only groups that did not present continuous detail reproduction of an intersection of 20 μm line. The elastic recovery was not statistically significant. The undesirable characteristics of VPS (lowest Shore A hardness and tensile strength) were observed when it was added to the composition of acrylic polymer (AP) and fiberglass (FG) in both concentrations, 20% and 40%. In groups AE and PAH, agglomerates of nanofillers were shown in SEM micrography, while the other groups presented different shapes and fillers sizes.


Assuntos
Polivinil/química , Siloxanas/química , Materiais para Moldagem Odontológica/química , Tamanho da Partícula , Valores de Referência , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo , Teste de Materiais , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Análise de Variância , Elasticidade , Testes de Dureza
7.
Cad. saúde pública ; 31(4): 691-700, 04/2015. tab, graf
Artigo em Espanhol | LILACS | ID: lil-744846

RESUMO

El objetivo del presente estudio fue hallar un modelo para estimar la incidencia de enfermedades tipo influenza (ETI), a partir de los términos de búsqueda relacionados recolectados por el Google Trends (GT). Los datos de vigilancia de ETI para los años 2012 y 2013 se obtuvieron del Sistema Nacional de Vigilancia de la Salud de Argentina. Las búsquedas de Internet se obtuvieron de la base de datos del GT, usando 6 términos: gripe, fiebre, tos, dolor de garganta, paracetamol e ibuprofeno. Se desarrolló un modelo de regresión de Poisson a partir de datos del año 2012, y se validó con datos del 2013 y resultados de la herramienta Google Flu Trends (GFT). La incidencia de ETI del sistema de vigilancia presentó fuertes correlaciones con las estimaciones de ETI del GT (r = 0,927) y del GFT (r = 0,943). Sin embargo, el GFT sobreestimó el pico de incidencia por casi el doble, mientras que el modelo basado en el GT subestimó el pico de incidencia por un factor de 0,7. Estos resultados demuestran la utilidad del GT como un complemento para la vigilancia de la influenza.


The aim of this study was to find a model to estimate the incidence of influenza-like illness (ILI) from the Google Trends (GT) related to influenza. ILI surveillance data from 2012 through 2013 were obtained from the National Health Surveillance System, Argentina. Internet search data were downloaded from the GT search engine database using 6 influenza-related queries: flu, fever, cough, sore throat, paracetamol, and ibuprofen. A Poisson regression model was developed to compare surveillance data and internet search trends for the year 2012. The model's results were validated using surveillance data for the year 2013 and results of the Google Flu Trends (GFT) tool. ILI incidence from the surveillance system showed strong correlations with ILI estimates from the GT model (r = 0.927) and from the GFT tool (r = 0.943). However, the GFT tool overestimates (by nearly twofold) the highest ILI incidence, while the GT model underestimates the highest incidence by a factor of 0.7. These results demonstrate the utility of GT to complement influenza surveillance.


O objetivo deste estudo foi encontrar um modelo para estimar a incidência da síndrome gripal com base nos termos de busca relacionados recolhidos pelo Google Trends (GT). Os dados de monitoramento de síndrome gripal entre 2012 e 2013 foram obtidos no Sistema Nacional de Vigilância de Saúde da Argentina. As pesquisas na Internet foram feitas baseando-se no banco de dados do GT usando 6 termos: gripe, febre, tosse, dor de garganta, paracetamol e ibuprofeno. Um modelo de regressão de Poisson foi desenvolvido valendo-se de dados de 2012. O modelo foi ajustado e validado com dados de 2013 e comparado com os resultados da ferramenta Google Flu Trends (GFT). A incidência de síndrome gripal mostrou uma forte correlação com estimativas do GT (r = 0,927) e GFT (r = 0,943). No entanto, o GFT superestimou o pico de incidência por quase o dobro, e o modelo baseado no GT subestimou o pico de incidência por um fator de 0,7. Esses resultados demonstram a utilidade do GT como um suplemento para a vigilância da influenza.


Assuntos
Cidades , Monitoramento Ambiental/estatística & dados numéricos , Poluentes Ambientais/análise , Siloxanas/análise , Resíduos/análise , Atmosfera/química , Biocombustíveis/análise , Carbono/análise , Água Doce/química , Estrutura Molecular , Siloxanas/química , Solo/química
8.
Braz. j. oral sci ; 13(2): 118-123, Apr-Jun/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-715602

RESUMO

AIM: To introduce a modification of the reline impression technique (MRIT), and compare the dimensional changes of impressions obtained by MRIT and by conventional reline impression technique (CRIT). METHODS: An acrylic resin tablet was milled by a CAD-CAM system to simulate three abutments (A, B and C) with different distances among them. The abutments were molded using both impression techniques. For MRIT, before completing the putty silicone polymerization, the relieve procedure was made by compression and it was immediately repositioned to complete the polymerization. Impressions were stored dry at room temperature for different periods (immediately, 1 h, 2 days and 7 days). The distances were obtained by scanning. The differences between the impressions and their respective matrix reference measurements were calculated to determine the dimensional changes. Data were subjected to ANOVA and Tukey's test (p<0.05). RESULTS: For AB and BC distances, there was no statistically significant difference between CRIT and MRIT (p=0.0597 and p=0.2167, respectively). For AC, there was statistically significant difference between the techniques for the immediate storage time (p=0.006). In general, for CRIT the material showed expansion, while for MRIT it showed contraction. CONCLUSIONS: It was verified that the addition silicon impressions obtained by both impression techniques showed dimensional stability, except for the immediate time-point...


Assuntos
Técnica de Moldagem Odontológica , Precisão da Medição Dimensional , Pesquisa , Materiais para Moldagem Odontológica/análise , Polivinil/uso terapêutico , Siloxanas/uso terapêutico
9.
J. appl. oral sci ; 20(5): 510-516, Sept.-Oct. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-654913

RESUMO

OBJECTIVES: Nanofilled composite resins are claimed to provide superior mechanical properties compared with microhybrid resins. Thus, the aim of this study was to compare nanofilled with microhybrid composite resins. The null hypothesis was that the size and the distribution of fillers do not influence the mechanical properties of surface roughness and wear after simulated toothbrushing test. MATERIAL AND METHODS: Ten rectangular specimens (15 mm x 5 mm x 4 mm) of Filtek Z250 (FZ2), Admira (A), TPH3 (T),Esthet-X (EX), Estelite Sigma (ES), Concept Advanced (C), Grandio (G) and Filtek Z350 (F) were prepared according to manufacturer's instructions. Half of each top surface was protected with nail polish as control surface (not brushed) while the other half was assessed with five random readings using a roughness tester (Ra). Following, the specimens were abraded by simulated toothbrushing with soft toothbrushes and slurry comprised of 2:1 water and dentifrice (w/w). 100,000 strokes were performed and the brushed surfaces were reanalyzed. Nail polish layers were removed from the specimens so that the roughness (Ra) and the wear could be assessed with three random readings (µm). Data were analyzed by ANOVA and Tukey's multiple-comparison test (α=0.05). RESULTS: Overall outcomes indicated that composite resins showed a significant increase in roughness after simulated toothbrushing, except for Grandio, which presented a smoother surface. Generally, wear ofnanofilled resins was significantly lower compared with microhybrid resins. CONCLUSIONS: As restorative materials suffer alterations under mechanical challenges, such as toothbrushing, the use of nanofilled materials seem to be more resistant than microhybrid composite resins, being less prone to be rougher and worn.


Assuntos
Humanos , Resinas Compostas/química , Desgaste dos Dentes/etiologia , Escovação Dentária/efeitos adversos , Polimento Dentário , Dentifrícios , Teste de Materiais , Metacrilatos/química , Nanotecnologia , Tamanho da Partícula , Propriedades de Superfície , Siloxanas/química , Escovação Dentária/métodos
10.
J. appl. oral sci ; 19(6): 628-633, Nov.-Dec. 2011. ilus, tab
Artigo em Inglês | LILACS | ID: lil-610878

RESUMO

OBJECTIVES: This study investigated the possible interactions between three addition silicone materials (Express®, Aquasil Ultra® and Adsil®), three hemostatic agents (ferric sulfate, StatGel FS®; aluminum sulfate, GelCord®; and aluminum chloride, Hemostop®) and gingival retraction cords previously handled with latex gloves to determine whether direct contact with medicaments or indirect contamination by latex in conditions similar to those found in clinical practice inhibit or affect the setting of the impression materials. MATERIAL AND METHODS: A portable device for the simultaneous test of several specimens was specifically developed for this study. Polymerization inhibition was analyzed by examination of the impressions and the molded surface. Ten trials were performed for each addition silicone material used in the study, at a total of 240 study samples. RESULTS: All the samples tested (N=240) were nonreactive regardless of the type of combination used. CONCLUSIONS: Aluminum sulfate, ferric sulfate and aluminum chloride hemostatic solutions did not show any inhibitory potential on the addition silicone samples under study, and there were no changes in polymerization as a result of contact between addition silicone and retraction cords handled with latex gloves.


Assuntos
Materiais para Moldagem Odontológica/química , Luvas Cirúrgicas , Hemostáticos/química , Látex/química , Polimerização/efeitos dos fármacos , Polivinil/química , Siloxanas/química , Enxofre/química , Técnicas de Retração Gengival , Teste de Materiais , Propriedades de Superfície , Silicones/química
11.
J. appl. oral sci ; 19(5): 517-520, Sept.-Oct. 2011. tab
Artigo em Inglês | LILACS | ID: lil-600853

RESUMO

OBJECTIVE: This study evaluated the surface energy and wettability of composite resins polymerized by different light-curing units to ascertain the good wetting of tooth surfaces to achieve adhesion. MATERIAL AND METHOD: Filtek Z350 (3M ESPE), Admira (VOCO) and Grandio (VOCO) resins were selected for the testing procedures. The resins were light cured using LED and Halogen devices. Contact angles were measured goniometrically (Ramé-Hart F100) using water and glycerol as test liquids. Surface energy values were calculated with a software program (DROPimage Standard) that uses the harmonic mean method applied to the acid-base theory. The data were analyzed statistically by ANOVA and Tukey's test with a significance of 0.05. RESULTS AND CONCLUSIONS: No statistically significant differences were found between the values of surface energy. The measured wettability differed statistically in most combinations as a function of the type of composite resin, type of light-curing unit, and the test liquid.


Assuntos
Humanos , Luzes de Cura Dentária , Resinas Compostas/química , Cura Luminosa de Adesivos Dentários/métodos , Análise de Variância , Resinas Compostas/efeitos da radiação , Teste de Materiais , Metacrilatos/química , Metacrilatos/efeitos da radiação , Siloxanas/química , Siloxanas/efeitos da radiação , Propriedades de Superfície/efeitos da radiação , Molhabilidade
12.
Braz. dent. j ; 22(2): 105-110, 2011. ilus, graf
Artigo em Inglês | LILACS | ID: lil-583797

RESUMO

The aim of this study was to evaluate the tissue compatibility of a silorane-based resin system (FiltekTM Silorane) and a methacrylate-based nanoparticle resin (FiltekTM Supreme XT) after implantation in the subcutaneous connective tissue of isogenic mice. One hundred and thirty five male isogenic BALB/c mice were randomly assigned to 12 experimental and 3 control groups, according to the implanted material and the experimental period of 7, 21 and 63 days. At the end of each period, the animals were killed and the tubes with the surrounding tissues were removed and processed for microscopic analysis. Samples were subjected to a descriptive and a semi-quantitative analyses using a 4-point scoring system (0-3) to evaluate the collagen fiber formation and inflammatory infiltrate. Data were statistically analyzed using the Kruskal Wallis test (?=0.05). The results showed that there was no significant difference between the experimental and control groups considering the three evaluation periods (p>0.05). The silorane-based and the methacrylate-based nanoparticle resins presented similar tissue response to that of the empty tube (control group) after subcutaneous implantation in isogenic mice.


O objetivo do presente estudo foi avaliar a compatibilidade tecidual de um sistema resinoso à base de silorane (FiltekTM Silorane) e de uma resina nanoparticulada à base de metacrilato (FiltekTM Supreme XT), após implantação no tecido conjuntivo subcutâneo de camundongos isogênicos. Um total de 135 camundongos isogênicos BALB/c machos foram randomicamente divididos em 12 grupos experimentais e em 3 grupos controles, de acordo com o material implantado e com o período experimental (7, 21 e 63 dias). Ao final de cada período, os animais foram mortos, sendo os tubos removidos com o tecido circundante e processados para análise microscópica. As lâminas foram submetidas a análise descritiva e análise semi-quantitativa empregando um sistema de escores de 4 pontos (0-3), a fim de avaliar a formação de fibras colágenas e o infiltrado inflamatório. Os dados obtidos foram submetidos à análise estatística por meio do teste de Kruskal Wallis (?=0,05). Os resultados mostraram que não houve diferença estatisticamente significante entre os grupos experimentais e controles, considerando os três períodos de avaliação (p>0,05). As resinas à base de silorane e à base de metacrilato apresentaram resposta tecidual semelhante à do tubo vazio (controle), após implantação no tecido conjuntivo de camundongos isogênicos.


Assuntos
Animais , Masculino , Camundongos , Resinas Compostas/toxicidade , Siloxanas/toxicidade , Tela Subcutânea/efeitos dos fármacos , Resinas Compostas/química , Reação a Corpo Estranho , Colágenos Fibrilares/biossíntese , Implantes Experimentais , Teste de Materiais , Camundongos Endogâmicos BALB C , Metacrilatos/toxicidade , Distribuição Aleatória
13.
Braz. dent. j ; 21(6): 520-527, 2010. ilus, tab
Artigo em Inglês | LILACS | ID: lil-572298

RESUMO

The aim of this study was to determine quantitatively and qualitatively the inorganic particle fraction of commercially available dental elastomers. The inorganic volumetric fraction of two addition silicones (Reprosil Putty/Fluid and Flexitime Easy Putty/Fluid), three condensation silicones (Clonage Putty/Fluid, Optosil Confort/Xantopren VL and Silon APS Putty/Fluid), one polyether (Impregum Soft Light Body) and one polysulfide (Permlastic Light Body) was accessed by weighing a previously determined mass of each material in water before and after burning samples at 600ºC, during 3 h. Unsettled material samples were soaked in acetone and chloroform for removal of tthe organic portion. The remaining filler particles were sputter-coated with gold evaluation of their morphology and size, under scanning electron microscopy (SEM). Flexitime Easy Putty was the material with the highest results for volumetric particle fraction, while Impregum Soft had the lowest values. Silon 2 APS Fluid presented the lowest mean filler size values, while Clonage Putty had the highest values. SEM micrographs of the inorganic particles showed several morphologies - lathe-cut, spherical, spherical-like, sticks, and sticks mixed to lathe-cut powder. The results of this study revealed differences in particle characteristics among the elastometic materials that could lead to different results when testing mechanical properties.


O objetivo desse estudo foi determinar quantitativamente e qualitativamente a fração de partículas inorgânicas de elastômeros dentais disponíveis comercialmente. A fração volumétrica de dois silicones por adição (Reprosil Denso/Fluído e Flexitime Denso/Fluído), três silicones por condensação (Clonage Denso/Fluído, Optosil/Xantopren, e Silon 2 APS Denso/Fluído), um poliéter (Impregum Soft Light) e um polissulfeto (Permlastic Light Body) foi determinada pela pesagem prévia de uma determinada massa de cada material em água antes e após a queima das amostras a 600ºC, por 3 h. Amostras de material não polimerizado foram imersas em acetona e clorofórmio para a remoção da parte orgânica. As partículas de carga remanescentes foram cobertas com uma camada de ouro para avaliação da sua morfologia e tamanho, em microscopia eletrônica de varredura. O material Flexitime Denso foi o material com maior fração volumétrica de partículas de carga, enquanto que o Impregum teve menor fração volumétrica. Silon 2 APS Fluído apresentou partículas de carga de menor tamanho, enquanto que o Clonage Denso apresentou as maiores partículas. A observação em MEV. mostrou partículas de carga com vários tipos de morfologia (esféricas, irregulares, semi-esféricas, retangulares e mistura de retangulares/irregulares). Os resultados desse estudo mostraram diferenças nas partículas de carga dos materiais, as quais podem levar a diferentes resultados em suas propriedades mecânicas.


Assuntos
Análise do Estresse Dentário , Materiais para Moldagem Odontológica/química , Elastômeros/química , Compostos Inorgânicos/análise , Teste de Materiais , Microscopia Eletrônica de Varredura , Tamanho da Partícula , Polivinil , Resinas Sintéticas/química , Espectrometria por Raios X , Siloxanas/química , Sulfetos/química , Viscosidade
14.
Braz. dent. j ; 21(6): 538-542, 2010. ilus, tab
Artigo em Inglês | LILACS | ID: lil-572301

RESUMO

The aim of this study was to investigate the influence of different composite resins - Filtek P90 (silorane-based composite) and Heliomolar (methacrylate-based composite) - on light transmission and decrease in Knoop hardness between the bottom and top of cured specimens. The irradiance of a light-curing unit (LCU) was measured with a power meter (Ophir Optronics; 900 mw/cm2) and spectral distributions were obtained using a spectrometer (USB 2000). Twenty standardized cylindrical specimens (2 mm thick x 7 mm diameter) of each composite resin were obtained by curing using the LCU for 40 s. Light energy transmission through the composite was calculated (n=10). The Knoop hardness number for each surface was recorded as the mean of 3 indentations. The difference in Knoop hardness between the top and bottom (DKH) of the same specimen was calculated (n=10). The irradiance of light that passed through Filtek P90 (272 mW/cm2) was not significantly greater than that the passed through Heliomolar (271 mW/cm2). The DKH of Filtek P90 (25 percent) was significantly higher than that of Heliomolar (12 percent). There was a greater degree of subsurface polymerization of the methacrylate-based composite compared to the silorane-based composite.


O objetivo deste estudo foi avaliar a influência da diferença entre a dureza do topo e da base em compósitos restauradores. Foram utilizados os compósitos restauradores Filtek P90 (compósito à base de silorano) e Heliomolar (compósito à base de metacrilato). A irradiância da unidade foto-ativadodora (UF) foi mensurada com um potenciômetro Ophir Optronics (900 mw/cm2) e o espectro de luz foi obtido usando um espectrofotômetro (USB 2000). Vinte espécimes cilíndricos padronizados (2 mm de espessura por 7 mm de diâmetro) foram obtidos pela fotoativação utilizando UF (40 s) para cada compósito. A irradiância que passou através do compósito foi mensurada (n=10). O número de dureza Knoop para cada superfície foi calculado pela média de 3 penetrações. A diferença da dureza Knoop entre o topo e base (DDK) de um mesmo espécime foi calculada (n=10). A irradiância que passou através da Filtek P90 (272 mW/cm2) não foi estatisticamente superior a Heliomolar (271 mW/cm2). A DDK da Filtek P90 (25 por cento) foi estatisticamente superior a Heliomolar (12 por cento). O compósito a base de metacrilato apresentou melhor grau de polimerização na base quando comparado ao compósito à base de silorano.


Assuntos
Resinas Compostas/química , Cura Luminosa de Adesivos Dentários , Resinas Acrílicas , Análise do Estresse Dentário , Dureza , Teste de Materiais , Metacrilatos , Fenômenos Ópticos , Polimerização , Poliuretanos , Siloxanas
15.
J. appl. oral sci ; 16(4): 280-285, July-Aug. 2008. graf, tab
Artigo em Inglês | LILACS | ID: lil-486497

RESUMO

In the present study, two types of tests (tensile strength test and polymerization inhibition test) were performed to evaluate the physical and chemical properties of four impression materials [a polysulfide (Permlastic), a polyether (Impregum), a condensation silicone (Xantopren) and a polyvinylsiloxane (Aquasil) ,3; when polymerized in contact with of one conventional (Hemostop) and two experimental (Vislin and Afrin) gingival retraction solutions. For the tensile strength test, the impression materials were mixed and packed into a steel plate with perforations that had residues of the gingival retraction solutions. After polymerization, the specimens were tested in tensile strength in a universal testing machine. For the polymerization inhibition test, specimens were obtained after taking impressions from a matrix with perforations that contained 1 drop of the gingival retraction solutions. Two independent examiners decided on whether or not impression material remnants remained unpolymerized, indicating interference of the chemical solutions. Based on the analysis of the results of both tests, the following conclusions were reached: 1. The tensile strength of the polysulfide decreased after contact with Hemostop and Afrin. 2. None of the chemical solutions inhibited the polymerization of the polysulfide; 3. The polyether presented lower tensile strength after polymerization in contact with the three gingival retraction agents; 4. The polyether had its polymerization inhibited only by Hemostop; 5. None of the chemical solutions affected the tensile strength of the condensation silicone; 6. Only Hemostop inhibited the polymerization of the condensation silicone; 7. The polyvinylsiloxane specimens polymerized in contact with Hemostop had significantly lower tensile strength; 8. Neither of the chemical solutions (Afrin and Vislin) affected the tensile strength of the polyvinylsiloxane and the condensation silicone; 9. Results of ...


Assuntos
Técnica de Moldagem Odontológica , Materiais para Moldagem Odontológica/química , Análise do Estresse Dentário , Dimetilpolisiloxanos/química , Gengiva/efeitos dos fármacos , Teste de Materiais , Transição de Fase , Polivinil/química , Resinas Sintéticas/química , Elastômeros de Silicone/química , Siloxanas/química , Soluções/química , Soluções/farmacologia , Sulfetos/química , Resistência à Tração
16.
J. appl. oral sci ; 16(1): 30-34, Jan.-Feb. 2008. tab
Artigo em Inglês | LILACS | ID: lil-472686

RESUMO

The aim of this study was to compare the shrinkage stress of composite resins by three methods. In the first method, composites were inserted between two stainless steel plates. One of the plates was connected to a 20 kgf load cell of a universal testing machine (EMIC-DL-500). In the second method, disk-shaped cavities were prepared in 2-mm-thick Teflon molds and filled with the different composites. Gaps between the composites and molds formed after polymerization were evaluated microscopically. In the third method, the wall-to-wall shrinkage stress of the resins that were placed in bovine dentin cavities was evaluated. The gaps were measured microscopically. Data were analyzed by one-way ANOVA and Tukey's test (alpha=0.05). The obtained contraction forces were: Grandio = 12.18 ± 0.428N; Filtek Z 250 = 11.80 ± 0.760N; Filtek Supreme = 11.80 ± 0.707 N; and Admira = 11.89 ± 0.647 N. The gaps obtained between composites and Teflon molds were: Filtek Z 250 = 0.51 ± 0.0357 percent; Filtek Supreme = 0.36 ± 0.0438 percent; Admira = 0.25 ± 0.0346 percent and Grandio = 0.16 ± 0.008 percent. The gaps obtained in wall-to-wall contraction were: Filtek Z 250 = 11.33 ± 2.160 µm; Filtek Supreme = 10.66 ± 1.211µm; Admira = 11.16 ± 2.041 µm and Grandio = 10.50 ± 1.224 µm. There were no significant differences among the composite resins obtained with the first (shrinkage stress generated during polymerization) and third method (wall-to-wall shrinkage). The composite resins obtained with the second method (Teflon method) differed significantly regarding gap formation.


Assuntos
Animais , Bovinos , Resinas Compostas/química , Materiais Dentários/química , Fenômenos Químicos , Preparo da Cavidade Dentária , Adaptação Marginal Dentária , Dentina/ultraestrutura , Teste de Materiais , Metacrilatos/química , Pressão , Polímeros/química , Politetrafluoretileno/química , Estresse Mecânico , Propriedades de Superfície , Siloxanas/química
17.
Braz. dent. j ; 17(3): 195-200, 2006. tab
Artigo em Inglês | LILACS | ID: lil-442366

RESUMO

This study evaluated the effect of disinfection methods [chemical disinfection (immersion in 100 ppm chloride solution) or microwave disinfection (690 W for 6 min)] on the internal adaptation of denture bases and resin surface roughness. For the adaptation test, 18 maxillary denture bases were obtained from stone casts duplicated from a metallic master model and submitted to the following treatments: 1) control (no disinfection), 2) chemical disinfection or 3) microwave disinfection. Disinfection procedures were performed twice (T1, T2) with a 7-day interval between them. Internal adaptation was measured at baseline (T0) and after T1 and T2 by weighing a vinyl polysiloxane film reproducing the gap between the resin base and the master model. For surface roughness measurement, 60 rectangular (5x10x40 mm) resin specimens were either mechanically or chemically polished and then submitted to the disinfection treatments. Surface roughness (Ra) was recorded after polishing (T0) and after T1 and T2. Data were analyzed by ANOVA GLM for repeated measures and Bonferroni correction at 5 percent significance level. Bases submitted to microwave disinfection had gradual increase of misfit, while bases immersed in chloride solution did not differ from the control group. Surface roughness increased in the mechanical polishing groups with microwave disinfection and decreased in the chemical polishing groups.


Este estudo avaliou o efeito de métodos de desinfecção [desinfecção química (imersão em solução clorada 100 ppm) ou desinfecção por microondas (690 W por 6 min)] na adaptação interna de bases de próteses totais e na rugosidade superficial da resina. Para o teste de adaptação, 18 bases superiores foram duplicadas a partir de um modelo-mestre metálico e submetidas aos seguintes tratamentos: 1) controle (sem desinfecção), 2) desinfecção química ou 3) desinfecção por microondas. Os procedimentos de desinfecção foram realizados duas vezes (T1, T2) com intervalo de 7 dias. A adaptação interna foi medida no baseline (T0), após T1 e T2 por pesagem de um filme de silicona de adição que reproduzia o espaço entre base de resina e modelo-mestre. Para a rugosidade superficial, 60 espécimes retangulares (5x10x40 mm) receberam polimento mecânico ou químico e foram submetidos aos tratamentos de desinfecção. A rugosidade superficial (Ra) foi registrada após o polimento (T0) e após T1 e T2. Os dados foram analisados por ANOVA GLM para medições repetidas e teste de Bonferroni com nível de significância de 5 por cento. As bases submetidas à desinfecção por microondas tiveram aumento gradual de desadaptação, enquanto que as bases imersas em solução clorada não diferiram do grupo controle. A rugosidade superficial aumentou nos grupos de polimento mecânico e desinfecção por microondas e diminuiu nos grupos de polimento químico.


Assuntos
Humanos , Bases de Dentadura , Materiais Dentários/química , Desinfecção/métodos , Micro-Ondas/uso terapêutico , Polimetil Metacrilato/química , Cloro/química , Materiais Dentários/efeitos da radiação , Polimento Dentário/métodos , Desinfetantes/química , Polimetil Metacrilato/efeitos da radiação , Polivinil/química , Propriedades de Superfície , Siloxanas/química , Fatores de Tempo
18.
Braz. dent. j ; 16(2): 98-102, maio-ago. 2005.
Artigo em Inglês | LILACS | ID: lil-413406

RESUMO

O objetivo deste estudo foi avaliar a microdureza de materiais resinosos polimerizados com unidades de fotoativação LED (diodos emissores de luz) e halógena. Vinte espécimes cilíndricos (3,0 mm de diâmetro e 2,0 mm de altura) foram preparados para cada material testado (Z100, Definite e Dyract). Os espécimes foram fotoativados na face superior (topo), utilizando duas unidades de fotoativação (Ultraled and Curing Light 2500), com tempos de 40 s e 60 s. As medidas de dureza foram realizadas nas superfícies do topo e da base de cada espécime. A análise estatística foi realizada por ANOVA e teste de Tukey (p<0,05). Não houve diferença significante na dureza na face superior entre as unidades LED e halógena para a Z100 e o Dyract. Por outro lado, a dureza foi menor quando a Definite foi polimerizada com o LED do que com a unidade halógena. Na base, a dureza de todos os materiais foi menor com o LED do que com a unidade halógena. A Z100 apresentou maior dureza que o Dyract e que a Definite independentemente da unidade de fotoativação. Não houve diferença significante na dureza entre os dois tempos de fotoativação para a face superior. Na base, a dureza foi maior quando os materiais foram polimerizados por 60 s. O LED não foi capaz de produzir a mesma dureza que a unidade halógena nos materiais resinosos testados.


Assuntos
Humanos , Resinas Compostas/química , Iluminação/instrumentação , Compômeros/química , Resinas Compostas/efeitos da radiação , Desenho de Equipamento , Dureza , Teste de Materiais , Polímeros/química , Dióxido de Silício/química , Siloxanas/química , Fatores de Tempo , Terpenos/química , Zircônio/química
19.
Braz. dent. j ; 14(1): 37-41, June 2003. tab
Artigo em Inglês | LILACS | ID: lil-340487

RESUMO

This study evaluated the effect of surface finishing methods on the average surface roughness of resin composites. Seven composites and two polishing systems were used. One hundred and twenty-six conical specimens of each material were prepared in stainless steel molds against a polyester strip. Forty-two of them remained intact and were used as controls. Each half of the remaining samples was polished with either diamond burs or diamond burs + aluminum oxide discs. The results showed no statistical difference in average surface roughness (Ra, µm) between the polyester strip and aluminum oxide discs (p>0.05). However, finishing with diamond burs showed a statistically higher average roughness for all composites (p<0.05). Statistical differences were detected among materials (p<0.05) in the use of diamond burs


Assuntos
Humanos , Resinas Compostas/química , Polimento Dentário , Análise de Variância , Óxido de Alumínio/química , Bis-Fenol A-Glicidil Metacrilato/química , Polimento Dentário/instrumentação , Diamante/química , Metacrilatos/química , Poliésteres/química , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Poliuretanos/química , Estatística como Assunto , Propriedades de Superfície , Siloxanas/química , Aço Inoxidável/química , Terpenos/química
20.
Rev. Fac. Odontol. (Córdoba) ; 19/20(1/2): 25-40, ene. 1991-dic. 1992. ilus
Artigo em Espanhol | LILACS | ID: lil-166139

RESUMO

Se describe un estudio clínico radiológico lineal en 15 pacientes donde se usaron esferas retentivas ("bola atache") para soportar prótesis completas inferiores y un compuesto polisiloxano vinílico para su fijación y retención. El plazo de seguimiento fue hasta de 5 años, correspondiendo: sexo: 6 masculinos, 9 femeninos; edad: 40 a 70 años. Los resultados muestran características satisfactorias ya que la reabsorción ósea controlada radiográficamente y corroborada por sonda roma de plástico, se presenta próxima a 1 mm. Fuerzas traumáticas pueden determinar algún fenómeno más pronunciado obedeciendo a circunstancias esencialmente locales y en relación a un sector del implante. La edad permite resultados muy satisfactorios en personas jóvenes, y el sexo no marcó diferencias significativas. Se describen las modificaciones de la técnica clásica en la aplicación de retenedores esféricos en forma directa y la utilización de un elastómero de consistencia fluida (polisiloxano vinílico de impresión de corrección) para lograr la fijación y retención de esta prótesis a los retenedores ("bola atache"), calculada por dinamómetro en 400 a 450 grs. Su aplicación en forma directa permite una adecuada oclusión que compensa el esfuerzo masticatorio y la resiliencia de la mucosa. El estudio clínico radiológico y el diagnóstico implantoprotético son condiciones fundamentales para determinar el número, diámetro y ubicación de los implantes con sus respectivas esferas retentivas


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Implantação Dentária Endóssea , Encaixe de Precisão de Dentadura/normas , Revestimento de Dentadura , Siloxanas/uso terapêutico , Compostos de Vinila
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...