Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
2.
Nutrients ; 16(14)2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-39064653

RESUMO

The introduction of closed-loop systems in the pediatric population has been a revolution in the management and evolution of diabetes. However, there are not many published studies in situations in which the feeding, schedules, and activities of the children deviate from the routine for which the systems were programmed, as in the case of a summer camp for children and adolescents with diabetes, where the specific programming of this device is not well known. It was a single-center prospective preliminary study. A total of twenty-seven patients (mean age 11.9 ± 1.9 years, 40% male, duration of diabetes 6.44 ± 2.83 years) were included (twenty with Medtronic MiniMed 780G system and seven with Tandem Control-IQ). Glucometric variables and pump functionality were monitored during the 7-day camp and in the following 3 weeks. There was no decrease from the objective TIR 70% at any moment. The worst results in Time Below Range were at 72 h from starting the camp, and the worst results in Time Above Range were in the first 24 h, with a progressive improvement after that. No episodes of level 3 hypoglycemia or ketoacidosis occurred. The use of specific programming in two integrated systems, with complex blood glucose regulation algorithms and not-prepared-for situations with increased levels of physical activity or abrupt changes in feeding routines, did not result in an increased risk of level 3 hypoglycemia and ketoacidosis for our pediatric type 1 diabetes (T1D) patients, regardless of the closed-loop device.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Sistemas de Infusão de Insulina , Insulina , Humanos , Criança , Masculino , Adolescente , Feminino , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Estudos Prospectivos , Insulina/administração & dosagem , Automonitorização da Glicemia/instrumentação , Hipoglicemiantes/administração & dosagem , Acampamento , Controle Glicêmico/métodos , Algoritmos , Hipoglicemia/prevenção & controle
3.
Eur J Med Res ; 29(1): 365, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39004734

RESUMO

BACKGROUND: Advanced Hybrid Closed-Loop system (AHCL) has profoundly changed type 1 diabetes therapy. This study primarily aimed to assess the impact on Glycemia Risk Index (GRI) and other continuous glucose monitoring (CGM) metrics when switching from one of four insulin strategies to AHCL in type 1 adult patients. METHODS: A single-center, retrospective pre/post observational study; 198 patients (age 44.4 ± 12.7 years, 115 females/83 males, diabetes duration 24.7 ± 11.6 years, HbA1c 7.4 ± 1%), treated with different insulin therapies (MDI, CSII, SAP with PLGS, HCL) were assessed before and after switching to an AHCL (MiniMed 780G, Diabeloop Roche, Tandem Control-IQ) at 1, 3, 6, and 12 months. Mixed-effects multivariable regression models were used to estimate the mean pre/post variations at different time points, adjusted for potential confounders. RESULTS: A month after the switch, there was an improvement in CGM metrics and HbA1c for all patients: GRI -10.7, GMI -0.27%, CV -2.1%, TAR>250 -3.7%, TAR180-250 -5.6%, TIR + 9.7%, HbA1c -0.54% (all p < 0.001). This improvement was maintained throughout the observational period (at 3, 6, and 12 months, with all p-values < 0.001). When improvements across the 780, Diabeloop, and Tandem CIQ devices were compared: Diabeloop demonstrated significantly better performance in terms of GRI, GMI, CV, TAR>250 at T1 (for all p < 0.01); 780 recorded highest average decrease in TAR180-250 (p = 0.020), while Tandem achieved the most significant reduction in TBR54-69 (p = 0.004). CONCLUSIONS: Adopting an AHCL leads to a rapid and sustained improvement in GRI and other parameters of metabolic control for up to a year, regardless of prior insulin therapies, baseline conditions or brands.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Sistemas de Infusão de Insulina , Insulina , Humanos , Masculino , Feminino , Adulto , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Glicemia/análise , Pessoa de Meia-Idade , Estudos Retrospectivos , Insulina/administração & dosagem , Insulina/uso terapêutico , Automonitorização da Glicemia/métodos , Hemoglobinas Glicadas/análise , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico
4.
Front Endocrinol (Lausanne) ; 15: 1347141, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38966218

RESUMO

Background and aims: Cystic fibrosis related diabetes (CFRD) is correlated with worsening of nutritional status and greater deterioration of lung function. The role of new technologies for the treatment of CFRD is little explored. The aim of the study was to evaluate the efficacy of Advanced Hybrid Closed Loop (AHCL) systems on glycemic control in CF patients. Methods: A single-center retrospective study on CFRD patients using AHCL systems was performed. Glycated hemoglobin (HbA1c) values and Continuous Glucose Monitoring (CGM) metrics were collected at T0 (AHCL placement), T1 (1-month), T2 (6-months) and T3 (1-year) to evaluate glycemic control. Results: 10 patients were included in the study. Data showed a reduction of HbA1c value (7.31 ± 0.34 to 6.35 ± 1.00; p=0.03), glycemic variability (p=0.05) and insulin requirement (p=0.03). The study population reached American Diabetes Association (ADA) recommended glycemic targets at 1-year. An increase in the Time in Range (TIR) and a reduction in time in hyperglycemia were also observed, although not statistically significant. Conclusions: In patients with CFRD, the use of AHCL leads to an improvement in glycemic control in terms of HbA1c and glycemic variability. The increase in TIR and the reduction of time in hyperglycemia, although not statistically significant, are extremely encouraging from a clinical point of view. Further studies with a larger population and a longer follow-up are needed. The results of this study demonstrate the importance of proposing the use of AHCL even in CF patients, who could benefit from glycemic improvement also in terms of nutritional status and respiratory function.


Assuntos
Glicemia , Fibrose Cística , Diabetes Mellitus , Hemoglobinas Glicadas , Controle Glicêmico , Humanos , Fibrose Cística/complicações , Projetos Piloto , Masculino , Feminino , Estudos Retrospectivos , Glicemia/análise , Glicemia/metabolismo , Hemoglobinas Glicadas/análise , Controle Glicêmico/métodos , Adulto , Automonitorização da Glicemia/métodos , Adolescente , Sistemas de Infusão de Insulina , Adulto Jovem , Insulina/uso terapêutico , Insulina/administração & dosagem , Hipoglicemiantes/uso terapêutico , Criança , Resultado do Tratamento
5.
Acta Diabetol ; 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38981873

RESUMO

Cystic fibrosis (CF)-related diabetes (CFRD), characterized by partial to complete impaired insulin secretion, is the most common extra-pulmonary complication of CF. Actually, insulin is the only approved therapy for its management. Advanced hybrid closed loop (AHCL) systems are the gold standard therapy for type 1 diabetes and have been proposed for other insulin-dependent forms of diabetes, including CFRD. With AHCL systems, people with CFRD can better manage several typical disease-related issues, such as minimal insulin requirements, its variability due to exacerbations or concomitant steroid therapies, nutritional behaviors, the co-existence of CF complications as intestinal malabsorption or liver disease. SmartGuard, the AHCL system for Medtronic Minimed 780G, requires a minimum of 8 units per day to operate. In this paper, we expose a case of two young women with CFRD with total daily insulin requirements < 8 UI, using off-label SmartGuard system over a 3 years of follow-up period, suggesting an evaluation of its use also in people with minimal insulin needs, considering its beneficial impact in glucose control and quality of life.

6.
Diabetes Obes Metab ; 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39010293

RESUMO

AIM: This study aims to provide a comprehensive overview of real-world evidence pertaining to disparities in the utilization of continuous glucose monitors (CGMs)/insulin pumps to highlight potential evidentiary gaps and discern emerging themes from the literature. MATERIALS AND METHODS: A systematic review of published manuscripts and abstracts was conducted from: MEDLINE, EMBASE, Nursing and Allied Health, Web of Science and CINHAL. Attributes related to patients, outcomes, interventions (CGMs/pumps/both) and study type were captured. In addition, factors associated with disparities in device utilization were examined. RESULTS: Thirty-six studies were included in the final analysis; the studies predominantly focused on people living with type 1 diabetes. Only two studies included individuals with type 2 diabetes. Almost two-thirds of the studies reported outcomes associated with disparities (e.g. glycated haemoglobin, diabetic ketoacidosis, resource utilization). Most studies highlighted disparities across race, ethnicity and insurance type. Evidentiary gaps were identified, particularly in the evidence for people with type 2 diabetes, the continuation of CGM/pump use and limited studies addressing disparities among Native Americans/American Indians. CONCLUSION: This study reveals critical disparities in diabetes technology use across race, ethnicity and insurance type, particularly among people with type 1 diabetes. Evidentiary gaps assessing disparities in diabetes technology use persist, particularly concerning people with type 2 diabetes, Native American/American Indian and LGBTQ+ populations, and in outcomes related to continuation of use. Social and digital determinants of health, such as income, transportation, residential location and technological literacy, are crucial to achieving equitable access. Future research should focus on the patient journey to identify opportunities for equitable access to diabetes technology as its use grows.

7.
Diabetes Ther ; 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39008237

RESUMO

The Tandem t:slim X2 insulin pump is a second-generation automated insulin delivery system with Control-IQ technology. It consists of an X2 insulin pump, an integrated Dexcom sensor, and an embedded 'Control-IQ' algorithm, which predicts glucose levels 30 min in the future, adapting the programmed basal insulin rates to get glucose levels between 112.5 and 160 mg/dl (8.9 mmol/l). The system delivers automatic correction boluses of insulin when glucose levels are predicted to rise > 180 mg/dl (10 mmol/l). It has been commercially available since 2016. We reviewed the current evidence about the psychological, safety, and exercise-related outcomes of this device in children, adolescents, and young adults living with type 1 diabetes. We screened 552 papers, but only 21 manuscripts were included in this review. Fear of hypoglycemia is significantly reduced in young people with diabetes and their parents. Interestingly, diabetes-related distress is decreased; thus, the system is well accepted by the users. The sleeping quality of subjects living with diabetes and their caregivers is improved to a lesser extent as well. Despite the small number of data, this system is associated with a low rate of exercise-related hypoglycemia. Finally, evidence from the literature shows that this system is safe and effective in improving psychological personal outcomes. Even if further steps toward the fully closed loop are still mandatory, this second-generation automated insulin delivery system reduces the burden of diabetes. It properly addresses most psychological issues in children, adolescents, and young adults with type 1 diabetes mellitus; thus, it appears to be well accepted.

8.
J Diabetes Metab Disord ; 23(1): 1397-1407, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38932805

RESUMO

Purpose: Advanced hybrid closed loop (AHCL) systems have the potential to improve glycemia and reduce burden for people with type 1 diabetes (T1D). Children and youth, who are at particular risk for out-of-target glycemia, may have the most to gain from AHCL. However, no randomized controlled trial (RCT) specifically targeting this age group with very high HbA1c has previously been attempted. Therefore, the CO-PILOT trial (Closed lOoP In chiLdren and yOuth with Type 1 diabetes and high-risk glycemic control) aims to evaluate the efficacy and safety of AHCL in this group. Methods: A prospective, multicenter, parallel-group, open-label RCT, comparing MiniMed™ 780G AHCL to standard care (multiple daily injections or continuous subcutaneous insulin infusion). Eighty participants aged 7-25 years with T1D, a current HbA1c ≥ 8.5% (69 mmol/mol), and naïve to automated insulin delivery will be randomly allocated to AHCL or control (standard care) for 13 weeks. The primary outcome is change in HbA1c between baseline and 13 weeks. Secondary outcomes include standard continuous glucose monitor glycemic metrics, psychosocial factors, sleep, platform performance, safety, and user experience. This RCT will be followed by a continuation phase where the control arm crosses over to AHCL and all participants use AHCL for a further 39 weeks to assess longer term outcomes. Conclusion: This study will evaluate the efficacy and safety of AHCL in this population and has the potential to demonstrate that AHCL is the gold standard for children and youth with T1D experiencing out-of-target glucose control and considerable diabetes burden. Trial registration: This trial was prospectively registered with the Australian New Zealand Clinical Trials Registry on 14 November 2022 (ACTRN12622001454763) and the World Health Organization International Clinical Trials Registry Platform (Universal Trial Number U1111-1284-8452). Supplementary Information: The online version contains supplementary material available at 10.1007/s40200-024-01397-4.

9.
Endocrine ; 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38814372

RESUMO

PURPOSE: To analyze the time in tight range (TITR), and its relationship with other glucometric parameters in patients with type 1 diabetes (T1D) treated with advanced hybrid closed-loop (AHCL) systems. METHODS: A prospective observational study was conducted on pediatric and adult patients with T1D undergoing treatment with AHCL systems for at least 3 months. Clinical variables and glucometric parameters before and after AHCL initiation were collected. RESULTS: A total of 117 patients were evaluated. Comparison of metabolic control after AHCL initiation showed significant improvements in HbA1c (6.9 ± 0.9 vs. 6.6 ± 0.5%, p < 0.001), time in range (TIR) (68.2 ± 11.5 vs. 82.5 ± 6.9%, p < 0.001), TITR (43.7 ± 10.8 vs. 57.3 ± 9.7%, p < 0.001), glucose management indicator (GMI) (6.9 ± 0.4 vs. 6.6 ± 0.3%, p < 0.001), time below range (TBR) 70-54 mg/dl (4.3 ± 4.5 vs. 2.0 ± 1.4%, p < 0.001), and time above range (TAR) > 180 mg/dl (36.0 ± 7.6 vs. 15.1 ± 6.4%, p < 0.001). Coefficient of variation (CV) also improved (36.3 ± 5.7 vs. 30.6 ± 3.7, p < 0.001), while time between 140-180 mg/dl remained unchanged. In total, 76.3% achieved TITR > 50% (100% pediatric). Correlation analysis between TITR and TIR and GRI showed a strong positive correlation, modified by glycemic variability. CONCLUSIONS: AHCL systems achieve significant improvements in metabolic control (TIR > 70% in 93.9% patients). The increase in TIR was not related to an increase in TIR 140-180 mg/dl. Despite being closely related to TIR, TITR allows for a more adequate discrimination of the achieved control level, especially in a population with good initial metabolic control. The correlation between TIR and TITR is directly influenced by the degree of glycemic variability.

10.
Artigo em Inglês | MEDLINE | ID: mdl-38758194

RESUMO

Background: We assessed real-life glycemic outcomes and predictors of composite measures of optimal glycemic control in children and adolescents with type 1 diabetes (T1D) during their initial 12 months of the MiniMed™ 780G use. Methods: This prospective observational multicenter study collected demographic, clinical, and 2-week 780G system data at five time points. Optimal glycemic control was defined as a composite glycemic control (CGC) score requiring the attainment of four recommended continuous glucose monitoring (CGM) targets, as well as the glycemia risk index (GRI) of hypoglycemia and hyperglycemia and composite CGM index (COGI). Outcome measures included longitudinal changes in multiple glycemic parameters and CGC, GRI, and COGI scores, as well as predictors of these optimal measures. Results: The cohort included 93 children, 43% girls, with a median age of 15.1 years (interquartile range [IQR] 12.9,17.0). A longitudinal analysis adjusted for age and socioeconomic index yielded a significant improvement in glycemic control for the entire cohort (ptime < 0.001) after the transition to 780G. The mean hemoglobin A1c (HbA1c) (SE) was 8.65% (0.12) at baseline and dropped by >1% after 1 year to 7.54% (0.14) (ptime < 0.001). Optimal glycemic control measures improved at 12 months post 780G; CGC improved by 5.6-fold (P < 0.001) and was attained by 24% of the participants, the GRI score improved by 10-fold (P = 0.009) and was achieved by 10% of them, and the COGI improved by 7.6-fold (P < 0.001) and was attained by 20% of them. Lower baseline HbA1c levels and increased adherence to Advanced Hybrid Closed-Loop (AHCL) usage were predictors of achieving optimal glycemic control. Conclusions: The AHCL 780G system enhances glycemic control in children and adolescents with T1D, demonstrating improvements in HbA1c and CGM metrics, albeit most participants did not achieve optimal glycemic control. This highlights yet ongoing challenges in diabetes management, emphasizing the need for continued proactive efforts on the part of health care professionals, youth, and caregivers.

11.
J Clin Med ; 13(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38592281

RESUMO

Background: Pregnant women with type 1 diabetes mellitus (T1DM) face an elevated risk of complications for both themselves and their newborns. Experts recommend strict glycemic control. The advanced hybrid closed-loop (AHCL) system, though not officially approved for pregnant T1DM patients, is promising for optimal glycemic control. Methods: We collected CGM metrics, HbA1c levels, insulin pump settings, and doses from a 33-year-old pregnant woman with 23-year history of T1DM from the 6th week of gestation to birth. She was initially on continuous insulin pump therapy with CGM and switched to the AHCL system (MiniMedTM 780G, Medtronic, Northridge, CA, USA) between weeks 13 and 14. Results: The AHCL system improved glycemic control from weeks 14 to 26, achieving international guidelines with TIR = 72%, TAR = 24%, TBR = 4%. At week 30, TIR was 66%, TAR 31%. By altering diet and adding 'fake carbohydrates', she maintained TIR ≥ 70%, TBR ≤ 4%, TAR ≤ 26% from week 34 to birth. A healthy 4 kg, 53 cm baby boy was born at week 38. Conclusions: The use of the AHCL system holds significant promise for improving glycemic control in pregnancy. Optimal glycemic control with MiniMedTM 780G in pregnancy requires accurate carbohydrate counting, specific timing of insulin doses in relation to meal consumption and dietary choices that reduce the glycemic load of meals continue to be crucial factors in achieving optimal glycemic control during pregnancy using the MiniMedTM 780G system. Further research and clinical studies are needed to explore the full potential of these advanced systems in managing T1DM during pregnancy and optimizing maternal and neonatal outcomes.

12.
J Diabetes Sci Technol ; : 19322968241242386, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38629871

RESUMO

BACKGROUND: There are few studies providing a more comprehensive picture of advanced hybrid closed-loop (AHCL) systems in clinical practice. The aim was to evaluate the effects of the AHCL systems, Tandem® t: slim X2™ with Control IQ™, and MiniMed™ 780G, on glucose control, safety, treatment satisfaction, and practical barriers for individuals with type 1 diabetes. METHOD: One hundred forty-two randomly selected adults with type 1 diabetes at six diabetes outpatient clinics in Sweden at any time treated with either the Tandem Control IQ (TCIQ) or the MiniMed 780G system were included. Glycated hemoglobin A1c (HbA1c) and glucose metrics were evaluated. Treatment satisfaction and practical barriers were examined via questionnaires. RESULTS: Mean age was 42 years, median follow-up was 1.7 years, 58 (40.8%) were females, 65% used the TCIQ system. Glycated hemoglobin A1c was reduced by 0.6% (6.8 mmol/mol; 95% confidence interval [CI] = 0.5-0.8% [5.3-8.2 mmol/mol]; P < .001), from 7.3% to 6.7% (57-50 mmol/mol). Time in range (TIR) increased with 14.5% from 57.0% to 71.5% (95% CI = 12.2%-16.9%; P < .001). Time below range (TBR) (<70 mg/dL, <3.9 mmol/L) decreased from 3.8% to 1.6% (P < .001). The standard deviation of glucose values was reduced from 61 to 51 mg/dL (3.4-2.9 mmol/L, P < .001) and the coefficient of variation from 35% to 33% (P < .001). Treatment satisfaction increased, score 14.8 on the Diabetes Treatment Satisfaction Questionnaire (DTSQ) (change version ranging from -18 to 18, P < .001). Four severe hypoglycemia events were detected and no cases of ketoacidosis. Skin problems were experienced by 32.4% of the study population. CONCLUSIONS: Advanced hybrid closed-loop systems improve glucose control with a reasonable safety profile and high treatment satisfaction. Skin problems are common adverse events.

13.
Eur J Pediatr ; 183(7): 3095-3103, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38661816

RESUMO

The study was carried out to determine the psychosocial outcomes of advanced hybrid closed-loop (AHCL) systems in children and adolescents with type 1 diabetes (T1D). Single-center and cohort study with a duration 6 months consisted of 60 children and adolescents with T1D. Standard clinical procedures, including both glycemic indicators, e.g., sensor-measured time within the 70-180 mg/dL range and glycated hemoglobin (HbA1c) levels, and psychosocial metrics were used for data collection. The psychosocial metrics included the Pediatric Quality of Life Inventory (PedsQL) 3.0 Diabetes Module for both children (8-12 years) and parents; the Quality of Life for Youth scale for adolescents (13-18 years); the Strengths and Difficulties Questionnaire (SDQ); the Hypoglycemia Fear Survey for Children (HFS-C); the Revised Child Anxiety and Depression Scale (R-CADS); and AHCLS-specific DTSEQ satisfaction and expectation survey. These metrics were evaluated at the baseline and after 6 months of AHCL use. Of the 60 children and adolescents with T1D for whom the AHCL system was utilized, 41 of them, 23 female and 18 male, completed the surveys. The mean age of the 41 children and adolescents was 12.5 ± 3.2 (min. 6.7, max. 18) years. The time spent within the target glycemic range, i.e., time-in-range (TIR), improved from 76.9 ± 9% at the baseline to 80.4 ± 5% after 6 months of AHCL system use (p = 0.03). Additionally, HbA1c levels reduced from 7.1% ± 0.7% at the baseline to 6.8% ± 0.8% after 6 months of AHCL system use (p = 0.03). The most notable decline in HbA1c was observed in participants with higher baseline HbA1c levels. All patients' HFS-C and AHCL system-specific DTSEQ satisfaction and expectation survey scores were within the normal range at the baseline and remained unchanged during the follow-up period. No significant difference was found in the R-CADS scores of children and adolescents between baseline and after 6 months of AHCL system use. However, there was a significant decrease in the R-CADS scores of the parents. Patients' PedsQL scores were high both at the baseline and after 6 months. The SDQ scores were high at baseline, and there was no significant improvement at the end of 6 months.  Conclusion: This is the first study to investigate in detail the psychosocial outcomes of AHCL system use in T1D patients and their parents. Although state-of-the-art technologies such as AHCL provide patients with more flexibility in their daily lives and information about glucose fluctuations, the AHCL resulted in a TIR above the recommended target range without a change in QOL, HFS-C, SDQ, and R-CADS scores. The scores obtained from the R-CADS conducted by the parents of the children indicated that the use of pumps caused a psychological improvement in the long term, with a significant decrease in the R-CADS scores of the children and adolescents with T1D. What is Known: • Previous studies focused on clinical outcomes of AHCL systems in pediatric T1D patients, showing glycemic control improvements. • Limited attention given to psychosocial outcomes of AHCL systems in children and adolescents with T1D. • Crucial psychosocial factors like quality of life, emotional well-being, and fear of hypoglycemia underexplored in AHCL system context. What is New: • First study to comprehensively examine psychosocial outcomes of AHCL systems in pediatric T1D patients. • Study's robust methodology sets new standard for diabetes technology research and its impact on qualiy of life.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 1 , Sistemas de Infusão de Insulina , Insulina , Qualidade de Vida , Humanos , Diabetes Mellitus Tipo 1/psicologia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/terapia , Criança , Masculino , Adolescente , Feminino , Sistemas de Infusão de Insulina/psicologia , Insulina/administração & dosagem , Automonitorização da Glicemia/psicologia , Automonitorização da Glicemia/métodos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Inquéritos e Questionários , Hipoglicemia/psicologia , Estudos de Coortes , Glicemia/análise , Resultado do Tratamento , Hemoglobinas Glicadas/análise
14.
Diabetes Res Clin Pract ; 211: 111680, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38657795

RESUMO

AIMS: To evaluate the effect of nutritional therapy on glycemic compensation and key cardio-renal risk markers in patients with diabetes and kidney transplant, on insulin treatment by Multiple Daily Injection (MDI) or Continuous Subcutaneous Insulin Infusion (CSII). METHODS: 34 patients with diabetes on insulin treatment and kidney transplant recipients were enrolled;12 participated in the structured nutritional program (intervention group), 22 patients (control group) did not receive nutritional protocol. Both groups were then divided into subgroups according to the method of insulin administration (MDI and CSII). RESULTS: Statistically significant reduction in fasting blood glucose values, glycosylated hemoglobin (HbA1c) and glycosuria were observed in both groups at the end of the study. The intervention group, significantly reduced total cholesterolemia and the glycemic index, together with reduced dietary intake of lipids, cholesterol, soluble carbohydrates and increased consumption of carbohydrates and fiber. These improvements were even more pronounced in patients treated with CSII. CONCLUSIONS: A proper nutritional approach optimize glycometabolic outcomes and contribute significantly to the reduction of the major cardiovascular risk factors in renal transplant patients.


Assuntos
Comportamento Alimentar , Controle Glicêmico , Insulina , Transplante de Rim , Terapia Nutricional , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Glicemia/metabolismo , Glicemia/análise , Hemoglobinas Glicadas/metabolismo , Hemoglobinas Glicadas/análise , Controle Glicêmico/métodos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem
15.
Diabet Med ; 41(8): e15333, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38671595

RESUMO

AIMS: Time in Tight Range (TITR) is a novel glycaemic metric in monitoring type 1 diabetes (T1D) management. The aim of this study was to assess the attainability of the TITR target in children and adolescents using the advanced hybrid closed loop (AHCL). METHODS: The 2128-day CGM data from 56 children and adolescents with T1D using AHCL (Minimed-780G) were analysed. Time in Range (TIR) (3.9-10 mmol/L), TITR (3.9-7.7 mmol/L), and other glycaemic parameters were separately analysed in terms of whole day, daytime (06.00-23:59), and nighttime (00.00-05.59) results. The participants were divided into two groups by autocorrection rate where Group 1 had a rate of <30% and Group 2 had a rate of ≥30. RESULTS: All glycaemic parameters indicated a better glycaemic outcome in the nighttime with higher TIR and TITR values compared with daytime (for TIR 87.5 ± 9.5% vs. 78.8 ± 8%, p < 0.001, and TITR 68.2 ± 13.5% vs. 57.5 ± 8.8%, p < 0.001). The rates of TITR >50% and >60% were 87% and 52%, respectively. When those with TITR >60% (n: 29) and those without (n: 27) were evaluated in terms of hypoglycaemia, no statistically significant difference was found in time below range (TBR) 3-3.9 mmol/L (0.3% vs. 2.1%, p: 0.084) and TBR < 3 mmol/L (0.47% vs. 0.3%, p: 0.298). Group 1 had a significantly higher TIR and TITR compared to Group 2 (82.6 ± 6.1% vs. 75.6 ± 8.6%, p: 0.008 and 62.1 ± 7.5% vs. 53.8 ± 7.5%, p: 0.002, respectively). CONCLUSIONS: Most children and adolescents on AHCL achieved the 50% target for TITR whereas more than half achieved the >60% target. A target of >50% for TITR seems realistic in children with T1D using AHCL.


Assuntos
Automonitorização da Glicemia , Glicemia , Diabetes Mellitus Tipo 1 , Estudos de Viabilidade , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Adolescente , Criança , Feminino , Masculino , Automonitorização da Glicemia/métodos , Glicemia/metabolismo , Hipoglicemiantes/uso terapêutico , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Insulina/uso terapêutico , Controle Glicêmico/métodos , Hemoglobinas Glicadas/metabolismo , Hemoglobinas Glicadas/análise , Hipoglicemia/induzido quimicamente , Fatores de Tempo
17.
J Clin Med ; 13(3)2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38337523

RESUMO

This review addresses the complexities of type 1 diabetes (T1D) and its associated complications, with a particular focus on diabetic retinopathy (DR). This review outlines the progression from non-proliferative to proliferative diabetic retinopathy and diabetic macular edema, highlighting the role of dysglycemia in the pathogenesis of these conditions. A significant portion of this review is devoted to technological advances in diabetes management, particularly the use of hybrid closed-loop systems (HCLSs) and to the potential of open-source HCLSs, which could be easily adapted to different patients' needs using big data analytics and machine learning. Personalized HCLS algorithms that integrate factors such as patient lifestyle, dietary habits, and hormonal variations are highlighted as critical to reducing the incidence of diabetes-related complications and improving patient outcomes.

18.
Front Endocrinol (Lausanne) ; 15: 1332418, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38390211

RESUMO

Background and aims: MiniMed 780G is the first Advanced Hybrid Closed Loop (AHCL) system in Poland, approved in the EU in 2020. To date, observations of glycemic control up to 12 months have been published. This study aimed to analyze glycemic control and anthropometric parameters in children and adolescents with type 1 diabetes (T1D) after two years of using the AHCL system. Materials and methods: We prospectively collected anthropometric data, pump, and continuous glucose records of fifty T1D children (9.9 ± 2.4 years, 24 (48%) boys, T1D for 3.9 ± 2.56 years) using an AHCL system. We compared the two-week AHCL records obtained after AHCL enrollment with data 6, 12, and 24 months after starting AHCL. Results: Time in range (70-180 mg/dl) and BMI z-score did not change during the 2 years of observation (p>0.05). The percentage of autocorrection in total daily insulin increased significantly (p<0.005). Conclusion: Glycemic control in the investigated group of children with T1D treated with the AHCL system for 2 years remained stable. Children in this group maintained weight and optimal metabolic control, most likely due to autocorrection boluses.


Assuntos
Líquidos Corporais , Diabetes Mellitus Tipo 1 , Adolescente , Masculino , Criança , Humanos , Feminino , Diabetes Mellitus Tipo 1/tratamento farmacológico , Controle Glicêmico , Estudos Prospectivos , Antropometria
19.
Diabetes Technol Ther ; 26(S3): 24-31, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38377317

RESUMO

Background: The MiniMed™ 780G system (MM780G) with Guardian™ 4 sensor includes a 100 mg/dL glucose target (GT) and automated insulin corrections up to every 5 min and was recently approved for use in the United States. In the present study, early real-world MM780G performance and the use of recommended system settings (100 mg/dL GT with an active insulin time of 2 h), by individuals with type 1 diabetes, were evaluated. Methods: CareLink™ personal data uploaded between the launch of the MM780G to August 22, 2023 were aggregated and underwent retrospective analysis (based on user consent) and if users had ≥10 days of continuous glucose monitoring (CGM) data. The 24-h day CGM metrics, including mean glucose, percentage of time spent in (%TIR), above (%TAR), and below (%TBR) target range (70-180 mg/dL), in addition to delivered insulin and closed-loop (CL) exits, were compared between an overall group (n = 7499) and individuals who used recommended settings (each, for >95% of the time). An analysis of the same metrics for MiniMed™ 770G system (MM770G) users (n = 3851) who upgraded to the MM780G was also conducted (paired t-test or Wilcoxon signed-rank test, P < 0.05 considered statistically significant). Results: For MM780G users, CGM use, and time in CL were >90% and all MM780G CGM metrics exceeded consensus-recommended goals. With recommended settings (22% of all users), mean %TIR and %TITR (70-140 mg/dL) were 81.4% and 56.4%, respectively. For individuals who upgraded from the MM770G, %TIR and %TITR increased from 73.2% to 78.3% and 45.8% to 52.6%, respectively, while %TAR reduced from 25.1% to 20.2% (P < 0.001, for all three). CL exits/week averaged <1, for all MM780G users. Conclusions: Early real-world MM780G use in the United States demonstrated a high percentage of time in range with low time above and below range. These outcomes are similar to those observed for real-world MM780G use in other countries.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Estados Unidos , Humanos , Automonitorização da Glicemia , Estudos Retrospectivos , Insulina/uso terapêutico , Insulina Regular Humana , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucose , Hipoglicemiantes/uso terapêutico , Sistemas de Infusão de Insulina
20.
Diabetes Technol Ther ; 26(S3): 7-16, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38377321

RESUMO

Background: The MiniMed™ 780G advanced hybrid closed-loop system (MM780G) builds on the basal automation and low-glucose protection features of the MiniMed™ 670G and 770G systems. While previous publications have focused on glycemic control improvements with MM780G, burden reduction has not been fully described. Methods: Data from two 3-month pivotal trials for the MM670G with Guardian™ Sensor 3 (GS3) (104 adults; 125 children) and MM780G with Guardian™ 4 Sensor (G4S) (67 adults;109 children) were compared. Real-world data (RWD) from United States users (N = 3851) transitioning from MM770G+GS3 to MM780G+G4S were also analyzed. Analyses included a new metric for diabetes management burden (i.e., pentagon composite metric), glycemic outcomes and system burden (e.g., closed-loop exits and fingersticks per day). Results: Diabetes burden metric (-22.8% and -28.5%), time in range (+3.1% [*P = 0.035] and +6.4% [P < 0.001]) and time below range (-1.8% [*P < 0.001] and -0.7% [*P < 0.001]) significantly improved, compared to MM670G for adult and pediatric participants, respectively. The pediatric mean sensor glucose (SG) reduced by -8.6 mg/dL (*P < 0.001), while the adults' saw no change. Closed-loop use significantly increased for both cohorts (+17.1% [*P < 0.001] and +20.5% [*P < 0.001]). Closed-loop exits were significantly reduced to about 1 per week (-0.5 [*P < 0.001] and -0.7 [*P < 0.001]); fingerstick tests were also reduced (-6.2 [*P < 0.001] and -6.9 [*P < 0.001]). Similar outcomes were observed from U.S. RWD. Conclusions: MiniMed™ 780G with G4S use was associated with significant reduction in diabetes management burden with fewer closed-loop exits, fingersticks and other interactions, and improvements in glycemic control when compared to the MiniMed™ 670G with GS3.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Adulto , Humanos , Criança , Hipoglicemiantes/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/uso terapêutico , Glicemia , Automonitorização da Glicemia , Sistemas de Infusão de Insulina , Glucose
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA