Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Anim. Reprod. (Online) ; 20(2): e20220110, 2023. tab, ilus, graf
Artigo em Inglês | VETINDEX | ID: biblio-1444259

Resumo

The aim of this study was to investigate uterine involution using ultrasonography techniques during postpartum. Postpartum ultrasonography evaluation (B-mode, color Doppler and Acoustic Radiation Force Impulse elastography) of the uterus was performed by transabdominal approach at immediate after birth and sequentially every 48 hours, during 30 days. The uterine echotexture did not present significant variations (P >0.05) being homogeneous in most evaluations; echogenicity of the uterus increased along the evaluation period (P =0.0452). Progressive and remarkable decrease of the total uterine diameter (UD) were observed (P <0.0001), especially during the first days postpartum. The thickness of uterine wall gradually decreased, as well the endometrial, myometrium and lumen diameters (P <0.0001). Uterine blood flow was assessed by Doppler and decreased during postpartum period, being significantly lower (P=0.0225) on the 30th day of postpartum. Uterine parenchyma presented as homogeneous dark areas (not deformable) on qualitative ultrasound elastography and the means shear velocity values of the uterine wall on quantitative elastography did not differ. This is the first study that evaluate the stiffness of uterine wall in healthy ewes, providing baseline data about quantitative and qualitative stiffness of the normal uterus, and it may be a useful tool for early diagnosis of uterine alterations during the postpartum period, using the reference parameter established for the assessment of uterine integrity during postpartum period.(AU)


Assuntos
Animais , Feminino , Útero/crescimento & desenvolvimento , Ovinos/fisiologia , Ultrassonografia/métodos , Período Pós-Parto/fisiologia , Rigidez Muscular/veterinária
2.
Rev. bras. reprod. anim ; 46(1): 17-27, Janeiro-Março 2022. tab
Artigo em Português | VETINDEX | ID: biblio-1378025

Resumo

O objetivo desta revisão foi descrever as principais técnicas de avaliação e achados ultrassonográficos da próstata canina. A ultrassonografia é o método de escolha para avaliação da glândula prostática, sendo imprescindível como auxílio no diagnóstico na detecção de anormalidades, principalmente quando há suspeita da presença de tumores. Com inovação dos equipamentos, surgiram técnicas complementares à ultrassonografia modo Bidimensional (B), tais como Doppler, ultrassonografia contrastada e elastografia, que aumentam a acurácia diagnóstica. O Doppler fornece informações sobre arquitetura vascular e aspectos hemodinâmicos dos vasos sanguíneos. A ultrassonografia contrastada permite determinar parâmetros relacionados à perfusão sanguínea das estruturas pelos agentes de contraste (ex.: microbolhas), definindo, portanto, padrões de alta e baixa intensidade da arquitetura vascular. A elastografia proporciona a avaliação da rigidez tecidual tanto de forma qualitativa, por meio de elastogramas, quanto quantitativa, por meio das velocidades de cisalhamento. Espera-se que esta revisão possa contribuir com informações relevantes aos leitores e veterinários da área de ultrassonografia e reprodução animal.(AU)


The purpose of this review was to describe the main assessment techniques and ultrasound findings of the canine prostate. Ultrasonography is the method of choice for assessing the prostate gland, being essential as an aid in the diagnosis in the detection of abnormalities, especially when the presence of tumors is suspected. With the innovation of the equipment, complementary techniques to B-mode ultrasonography have emerged, such as Doppler, contrasted ultrasound and elastography, which increase the diagnostic accuracy. Doppler provides information on vascular architecture and hemodynamic aspects of blood vessels. Contrast ultrasonography allows to determine parameters related to the blood perfusion of structures by contrast agents (eg, microbubbles), thus defining high and low intensity patterns of vascular architecture. ARFI elastography provides assessment of tissue stiffness both qualitatively, using elastograms, and quantitative, using shear speeds. It is hoped that this review can contribute with relevant information to readers and veterinarians in the area of asound and animal reproduction.(AU)


Assuntos
Animais , Cães , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ultrassonografia Doppler/métodos , Equipamentos para Diagnóstico/veterinária , Técnicas de Imagem por Elasticidade/métodos , Vasos Sanguíneos/diagnóstico por imagem , Meios de Contraste/efeitos adversos , Microbolhas/veterinária , Imagem de Perfusão/veterinária , Rigidez Vascular/fisiologia
3.
Artigo em Inglês | LILACS-Express | LILACS, VETINDEX | ID: biblio-1487663

Resumo

ABSTRACT: Objective was to evaluate the accuracy of elastography in the differentiation between normal and cataract lenses One hundred forty-five eyes of 98 dogs were divided into groups according to cataract stage. Forty-twoeyes were submitted to phacoemulsification. Biometric parameters, echogenicity and echotexture patterns of the anterior, posterior and vitreous chambers, lens and retina-choroid-sclera complexes were evaluated by ocular ultrasound in modes A and B. Deformability, and color (blue color = indicated less rigid structures, color red = more rigid structures) of the lenses were evaluated by the elastogram. The shear wave velocity (SWV; m/s) was calculated in three regions of the lens, both in the cortex and in the nucleus. The SWV of nucleus was statistically different between the normal lenses and with cataracts, and between the stages of cataract (P 0.001). Healthy lenses and incipient cataracts had a more rigid nucleus. Mature cataracts presented lowest nuclear rigidity (P 0.001). On cortical region the SWV was significantly higher (P 0.01) in intumescent and incipient cataracts. SWV less than 2.67m/s indicates cataract with a sensitivity of 72% and specificity of 94%. Values lower than 2.23m/s suggest mature cataract, with sensitivity of 71% and specificity of 76%. SWV greater than 2.66 m/s are associated with normal lenses or incipient cataract, presenting sensitivity of 94% and specificity of 84%. Qualitative method allowed differentiation between healthy and affected lenses and the classification of evolutionary stages. There was a correlation between the degree of stiffness of lens in cortical and nuclear regions (p=00165, r=0.37) and between the balanced saline solution quantitative and surgical time (P 0.01, r=0.73). Degree of stiffness of lens did not correlate with parameters of phacoemulsification. Elastographic proved feasible for evaluating the lens of dogs, characterizing the types of cataracts, and demonstrating increased stiffness of the diseased lenses.


RESUMO: O objetivo foi avaliar a precisão da elastografia na diferenciação entre lentes normais e de catarata. Cento e quarenta e cinco olhos de 98 cães foram divididos em grupos de acordo com o estágio de maturação da catarata. Quarenta e dois olhos foram submetidos à facoemulsificação. Parâmetros biométricos, ecogenicidade e padrões de ecotextura das câmaras anterior, posterior e vítrea, lente e complexos retina-coróide-esclera foram avaliados por ultrassonografia ocular nos modos A e B. A deformabilidade e a coloração (cor azul = indicou estruturas menos rígidas, cor vermelha = estruturas mais rígidas) das lentes foram avaliadas pelo elastograma. A velocidade da onda de cisalhamento (SWV; m/s) foi calculada em três regiões da lente, tanto no córtex quanto no núcleo. A SWV do núcleo foi estatisticamente diferente entre as lentes normais e com catarata e entre os estágios da catarata (P 0,001). Lentes saudáveis e cataratas incipientes tinham um núcleo mais rígido. Cataratas maduras apresentaram menor rigidez nuclear (P 0,001). Na região cortical, a SWV foi significativamente maior (P 0,01) nas cataratas intumescentes e incipientes. Uma SWV menor que 2,67m/s indica catarata com sensibilidade de 72% e especificidade de 94%. Valores inferiores a 2,23m/s sugerem catarata madura, com sensibilidade de 71% e especificidade de 76%. Uma SWV superior a 2,66m/s está associada à catarata normal ou incipiente, apresentando sensibilidade de 94% e especificidade de 84%. O método qualitativo permitiu a diferenciação entre lentes normais de olhos saudáveis e afetadas e a classificação dos estágios evolutivos. A elastografia se mostrara uma ferramenta viável para avaliar as lentes de cães, caracterizando os tipos de catarata e demonstrando maior rigidez das lentes doentes.

4.
Pesqui. vet. bras ; 41: e06598, 2021. tab, graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1340345

Resumo

Objective was to evaluate the accuracy of elastography in the differentiation between normal and cataract lenses One hundred forty-five eyes of 98 dogs were divided into groups according to cataract stage. Forty-twoeyes were submitted to phacoemulsification. Biometric parameters, echogenicity and echotexture patterns of the anterior, posterior and vitreous chambers, lens and retina-choroid-sclera complexes were evaluated by ocular ultrasound in modes A and B. Deformability, and color (blue color = indicated less rigid structures, color red = more rigid structures) of the lenses were evaluated by the elastogram. The shear wave velocity (SWV; m/s) was calculated in three regions of the lens, both in the cortex and in the nucleus. The SWV of nucleus was statistically different between the normal lenses and with cataracts, and between the stages of cataract (P<0.001). Healthy lenses and incipient cataracts had a more rigid nucleus. Mature cataracts presented lowest nuclear rigidity (P<0.001). On cortical region the SWV was significantly higher (P<0.01) in intumescent and incipient cataracts. SWV less than 2.67m/s indicates cataract with a sensitivity of 72% and specificity of 94%. Values lower than 2.23m/s suggest mature cataract, with sensitivity of 71% and specificity of 76%. SWV greater than 2.66 m/s are associated with normal lenses or incipient cataract, presenting sensitivity of 94% and specificity of 84%. Qualitative method allowed differentiation between healthy and affected lenses and the classification of evolutionary stages. There was a correlation between the degree of stiffness of lens in cortical and nuclear regions (p=00165, r=0.37) and between the balanced saline solution quantitative and surgical time (P<0.01, r=0.73). Degree of stiffness of lens did not correlate with parameters of phacoemulsification. Elastographic proved feasible for evaluating the lens of dogs, characterizing the types of cataracts, and demonstrating increased stiffness of the diseased lenses.(AU)


O objetivo foi avaliar a precisão da elastografia na diferenciação entre lentes normais e de catarata. Cento e quarenta e cinco olhos de 98 cães foram divididos em grupos de acordo com o estágio de maturação da catarata. Quarenta e dois olhos foram submetidos à facoemulsificação. Parâmetros biométricos, ecogenicidade e padrões de ecotextura das câmaras anterior, posterior e vítrea, lente e complexos retina-coróide-esclera foram avaliados por ultrassonografia ocular nos modos A e B. A deformabilidade e a coloração (cor azul = indicou estruturas menos rígidas, cor vermelha = estruturas mais rígidas) das lentes foram avaliadas pelo elastograma. A velocidade da onda de cisalhamento (SWV; m/s) foi calculada em três regiões da lente, tanto no córtex quanto no núcleo. A SWV do núcleo foi estatisticamente diferente entre as lentes normais e com catarata e entre os estágios da catarata (P<0,001). Lentes saudáveis e cataratas incipientes tinham um núcleo mais rígido. Cataratas maduras apresentaram menor rigidez nuclear (P<0,001). Na região cortical, a SWV foi significativamente maior (P<0,01) nas cataratas intumescentes e incipientes. Uma SWV menor que 2,67m/s indica catarata com sensibilidade de 72% e especificidade de 94%. Valores inferiores a 2,23m/s sugerem catarata madura, com sensibilidade de 71% e especificidade de 76%. Uma SWV superior a 2,66m/s está associada à catarata normal ou incipiente, apresentando sensibilidade de 94% e especificidade de 84%. O método qualitativo permitiu a diferenciação entre lentes normais de olhos saudáveis e afetadas e a classificação dos estágios evolutivos. A elastografia se mostrara uma ferramenta viável para avaliar as lentes de cães, caracterizando os tipos de catarata e demonstrando maior rigidez das lentes doentes.(AU)


Assuntos
Masculino , Cães , Catarata/veterinária , Cães , Técnicas de Imagem por Elasticidade/veterinária , Ultrassom , Facoemulsificação
5.
Acta sci. vet. (Impr.) ; 49(suppl.1): Pub.621-Jan 4, 2021. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1458484

Resumo

Background: A detailed ultrasound examination of the fetal urinary tract as part of prenatal care is important to detect possibleabnormalities. Early diagnosis can prevent more serious damage such as loss of kidney function. Interstitial nephritis cancompromise renal functionality. Also, acute interstitial nephritis is a frequent cause of acute kidney injury and can becomechronic if not treated. Besides, a renal biopsy can help in the diagnosis and at the staging of the disease. Therefore, thisreport aims to describe the ultrasonographic findings of the renal tissues in a canine fetus affected by interstitial nephritis.Case: Gestational ultrasound evaluations were performed in a female Pug, at the 25th, 45th, and 58th gestational days.Ultrasound examination was performed with a 9.0 MHz linear transducer and a high-resolution digital transducer with afrequency standardized at 17.0 MHz. During the first evaluation, embryonic vesicles were detected and were compatible withthe gestational period. At 45 days of gestation, some abnormalities were observed in the kidneys of one of the fetuses, suchas increased cortical echogenicity, cortical thickening, loss of corticomedullary ratio (1:1), renal pelvis and ureter dilatationby echogenic content. Biparietal and abdominal diameters were also lower than that from the other fetuses, which did notshow abnormalities, being compatible with the estimated gestational age. However, the heart rate was similar among allfetuses. On the 58th day, we observed in the underdeveloped fetus that both kidneys still presented the abnormalities seenpreviously, in addition to the presence of a cystic structure in the right kidney, in the cranial...


Assuntos
Feminino , Animais , Gravidez , Cães , Cães/anormalidades , Desenvolvimento Fetal , Nefrite Intersticial/veterinária , Rim/anormalidades , Cuidado Pré-Natal , Ultrassonografia Pré-Natal/veterinária
6.
Pesqui. vet. bras ; 41: e06598, 2021. tab, graf
Artigo em Inglês | VETINDEX | ID: vti-764854

Resumo

Objective was to evaluate the accuracy of elastography in the differentiation between normal and cataract lenses One hundred forty-five eyes of 98 dogs were divided into groups according to cataract stage. Forty-twoeyes were submitted to phacoemulsification. Biometric parameters, echogenicity and echotexture patterns of the anterior, posterior and vitreous chambers, lens and retina-choroid-sclera complexes were evaluated by ocular ultrasound in modes A and B. Deformability, and color (blue color = indicated less rigid structures, color red = more rigid structures) of the lenses were evaluated by the elastogram. The shear wave velocity (SWV; m/s) was calculated in three regions of the lens, both in the cortex and in the nucleus. The SWV of nucleus was statistically different between the normal lenses and with cataracts, and between the stages of cataract (P<0.001). Healthy lenses and incipient cataracts had a more rigid nucleus. Mature cataracts presented lowest nuclear rigidity (P<0.001). On cortical region the SWV was significantly higher (P<0.01) in intumescent and incipient cataracts. SWV less than 2.67m/s indicates cataract with a sensitivity of 72% and specificity of 94%. Values lower than 2.23m/s suggest mature cataract, with sensitivity of 71% and specificity of 76%. SWV greater than 2.66 m/s are associated with normal lenses or incipient cataract, presenting sensitivity of 94% and specificity of 84%. Qualitative method allowed differentiation between healthy and affected lenses and the classification of evolutionary stages. There was a correlation between the degree of stiffness of lens in cortical and nuclear regions (p=00165, r=0.37) and between the balanced saline solution quantitative and surgical time (P<0.01, r=0.73). Degree of stiffness of lens did not correlate with parameters of phacoemulsification. Elastographic proved feasible for evaluating the lens of dogs, characterizing the types of cataracts, and demonstrating increased stiffness of the diseased lenses.(AU)


O objetivo foi avaliar a precisão da elastografia na diferenciação entre lentes normais e de catarata. Cento e quarenta e cinco olhos de 98 cães foram divididos em grupos de acordo com o estágio de maturação da catarata. Quarenta e dois olhos foram submetidos à facoemulsificação. Parâmetros biométricos, ecogenicidade e padrões de ecotextura das câmaras anterior, posterior e vítrea, lente e complexos retina-coróide-esclera foram avaliados por ultrassonografia ocular nos modos A e B. A deformabilidade e a coloração (cor azul = indicou estruturas menos rígidas, cor vermelha = estruturas mais rígidas) das lentes foram avaliadas pelo elastograma. A velocidade da onda de cisalhamento (SWV; m/s) foi calculada em três regiões da lente, tanto no córtex quanto no núcleo. A SWV do núcleo foi estatisticamente diferente entre as lentes normais e com catarata e entre os estágios da catarata (P<0,001). Lentes saudáveis e cataratas incipientes tinham um núcleo mais rígido. Cataratas maduras apresentaram menor rigidez nuclear (P<0,001). Na região cortical, a SWV foi significativamente maior (P<0,01) nas cataratas intumescentes e incipientes. Uma SWV menor que 2,67m/s indica catarata com sensibilidade de 72% e especificidade de 94%. Valores inferiores a 2,23m/s sugerem catarata madura, com sensibilidade de 71% e especificidade de 76%. Uma SWV superior a 2,66m/s está associada à catarata normal ou incipiente, apresentando sensibilidade de 94% e especificidade de 84%. O método qualitativo permitiu a diferenciação entre lentes normais de olhos saudáveis e afetadas e a classificação dos estágios evolutivos. A elastografia se mostrara uma ferramenta viável para avaliar as lentes de cães, caracterizando os tipos de catarata e demonstrando maior rigidez das lentes doentes.(AU)


Assuntos
Masculino , Cães , Catarata/veterinária , Cães , Técnicas de Imagem por Elasticidade/veterinária , Ultrassom , Facoemulsificação
7.
Acta sci. vet. (Online) ; 49(suppl.1): Pub. 621, Mar. 25, 2021. ilus
Artigo em Inglês | VETINDEX | ID: vti-30102

Resumo

Background: A detailed ultrasound examination of the fetal urinary tract as part of prenatal care is important to detect possibleabnormalities. Early diagnosis can prevent more serious damage such as loss of kidney function. Interstitial nephritis cancompromise renal functionality. Also, acute interstitial nephritis is a frequent cause of acute kidney injury and can becomechronic if not treated. Besides, a renal biopsy can help in the diagnosis and at the staging of the disease. Therefore, thisreport aims to describe the ultrasonographic findings of the renal tissues in a canine fetus affected by interstitial nephritis.Case: Gestational ultrasound evaluations were performed in a female Pug, at the 25th, 45th, and 58th gestational days.Ultrasound examination was performed with a 9.0 MHz linear transducer and a high-resolution digital transducer with afrequency standardized at 17.0 MHz. During the first evaluation, embryonic vesicles were detected and were compatible withthe gestational period. At 45 days of gestation, some abnormalities were observed in the kidneys of one of the fetuses, suchas increased cortical echogenicity, cortical thickening, loss of corticomedullary ratio (1:1), renal pelvis and ureter dilatationby echogenic content. Biparietal and abdominal diameters were also lower than that from the other fetuses, which did notshow abnormalities, being compatible with the estimated gestational age. However, the heart rate was similar among allfetuses. On the 58th day, we observed in the underdeveloped fetus that both kidneys still presented the abnormalities seenpreviously, in addition to the presence of a cystic structure in the right kidney, in the cranial...(AU)


Assuntos
Animais , Feminino , Gravidez , Cães , Cães/anormalidades , Nefrite Intersticial/veterinária , Desenvolvimento Fetal , Rim/anormalidades , Ultrassonografia Pré-Natal/veterinária , Cuidado Pré-Natal
8.
Artigo em Inglês | LILACS-Express | LILACS, VETINDEX | ID: biblio-1487655

Resumo

ABSTRACT: The objective of this study was to verify the applicability of B-mode ultrasonography, ARFI elastography and CEUS in the diagnosis of chronic kidney disease and its Stages in dogs. 24 healthy dogs and 28 with CKD were included. In B-mode, the echogenicity, echotexture and cortico-medullary ratio of the kidneys were verified. By elastography, the shear-wave velocity of the cortical (SWVcort) and medullary (SWVmed) regions were determined and tissue deformity was evaluated. Wash-in, wash-out and peak enhancement (TPic) of the contrast in the renal parenchyma were calculated and homogeneity, presence of filling gaps and distinction of filling phases were evaluated by CEUS. Changes in echogenicity, echotexture and cortico-medullary ratio were observed only in sick patients. There was an increase in SWVcort in CKD, with a cutoff point >2.91m/s. Healthy kidneys were non-deformable and 25% had changes in gray scales. There was an increase in wash-in and TPic, changes in filling characteristics, filling failures and difficulty in distinguishing between the Stages in CEUS in CKD. It was found that dogs with CKD 2, 3 and 4 had greater SWVcort and wash-in values than CKD 1. Elastographic and CEUS changes were observed in dogs with CKD, demonstrating the applicability of ultrasonographic techniques in their diagnosis.


RESUMO: O objetivo deste estudo foi verificar a aplicabilidade da ultrassonografia modo-B, elastografia ARFI e CEUS no diagnóstico da doença renal crônica e seus estágios em cães. Foram incluídos 24 cães saudáveis e 28 com DRC. Pelo modo-B, verificou-se ecogenicidade, ecotextura e relação córtico-medular dos rins. Pela elastografia, foram determinadas as velocidades de cisalhamento das regiões cortical (SWVcort) e medular (SWVmed) e foi avaliada a deformidade tecidual. Calculou-se os temos de wash-in, wash-out e pico de intensidade (TPic) do parênquima renal e avaliou-se homogeneidade, presença de falhas e distinção das fases de preenchimento por contraste por meio de CEUS. Alterações em ecogenicidade, ecotextura e relação córtico-medular foram observadas somente em pacientes doentes. Houve aumento da SWVcort na DRC, com ponto de corte >2.91m/s. Rins saudáveis foram não-deformáveis e 25% apresentou alterações nas escalas de cinza. Houve aumento do wash-in e TPic, alterações nas características de preenchimento, falhas e dificuldade para distinguir as fases de preenchimento do contraste nos rins com DRC. Verificou-se que cães com DRC graus 2, 3 e 4 tiveram valores de SWVcort e wash-in maiores que cães com DRC grau 1. Foram obsrervadas alterações elastográfica e de CEUS em cães com DRC, demonstrando a aplicabilidade destas técnicas ultrassonográficas no seu diagnóstico.

9.
Artigo em Inglês | LILACS-Express | LILACS, VETINDEX | ID: biblio-1487656

Resumo

ABSTRACT: The objective of the present study was to obtain echobiometric values for the most important canine maternal-fetal tissues using high-definition ultrasonography (HDUS) trying to update the formulas for predicting gestational age. Twelve healthy bitches of brachycephalic breeds weighing 7-13kg and aged one to four years were included. The fetuses were analyzed every day using conventional and high-definition ultrasonography from the eighth day after artificial insemination until the day of delivery, using the ACUSON S2000/SIEMENS ultrasound equipment and specific software. Embryonic and fetal structures; diameter of the embryonic vesicle; length of the embryo; biparietal diameter, abdominal length and kidney height; length of the femur, humerus, scapula, radius, and tibia; thickening of the stomach wall; adrenal length; and cardiac size were measured. These variables were correlated with gestational and adjusted tested according to regression models. The results obtained (P 0.001) for: lateral diameter of the gestational sac (R2=81.8%); length of the embryo (R2=85.7%); biparietal (R2=99.1%) and abdominal diameter (R2=97.2%); thickness of the gastric wall (R2=86.9%); length of the femur (R2=96.6%), radius (R2=97.5%), humerus (R2=96.5%), scapula (R2=95.8%) and tibia (R2=97.3%); kidney length (R2=95.8%) and height (R2=96.0%); adrenal length (R2=89.6%); heart length (R2=93.0%) and height (R2=91.5%) of the canine fetuses showed significant correlation with gestational days. This allowed monitoring fetal growth and estimation of age with high accuracy in different gestational periods.


RESUMO: O objetivo do presente estudo foi obter valores ecobiométricos para os tecidos materno-fetais caninos, usando a ultrassonografia de alta definição (HDUS), desenvolvendo fórmulas para prever a idade gestacional das cadelas. Doze cadelas saudáveis de raças braquicefálicas pesando 7-13kg e com idades entre um e quatro anos foram incluídas. Os fetos foram analisados diariamente com ultrassonografia convencional e de alta definição, do oitavo dia após a inseminação artificial até o dia do parto, utilizando o equipamento de ultrassom ACUSON S2000/SIEMENS e software específico. Estruturas embrionárias e fetais; diâmetro da vesícula embrionária; comprimento do embrião; diâmetro biparietal, comprimento abdominal e altura renal; comprimento do fêmur, úmero, escápula, rádio e tíbia; espessamento da parede do estômago; comprimento adrenal; e tamanho cardíaco foram medidos. Essas variáveis foram correlacionadas com o teste gestacional e ajustado de acordo com os modelos de regressão. Os resultados obtidos (P 0,001) para: diâmetro lateral do saco gestacional (R2=81,8%); comprimento do embrião (R2=85,7%); diâmetro biparietal (R2=99,1%) e abdominal (R2=97,2%); espessura da parede gástrica (R2=86,9%); comprimento do fêmur (R2=96,6%), rádio (R2=97,5%), úmero (R2=96,5%), escápula (R2=95,8%) e tíbia (R2=97,3%); comprimento do rim (R2=95,8%) e altura (R2=96,0%); comprimento adrenal (R2=89,6%); o comprimento do coração (R2=93,0%) e a altura (R2=91,5%) dos fetos caninos apresentaram correlação significativa com os dias gestacionais. Isso permitiu monitorar o crescimento fetal e estimar a idade com alta precisão em diferentes períodos gestacionais.

10.
Anim. Reprod. (Online) ; 18(4): e20210023, 2021. tab, graf
Artigo em Inglês | LILACS-Express | VETINDEX | ID: biblio-1349957

Resumo

Abstract The aim of this study was to measure the nuchal translucency (NT) of canine fetuses to establish reference values ​​for healthy gestational processes and to verify its effectiveness in the diagnosis of congenital abnormalities. On day 34 of gestation, the NT of three fetuses from each of the 26 English bulldog female dogs was measured. The first fetus was the one located immediately cranial to the bladder, the second was selected from the left side of the abdomen, and the third from the right side. The reference values for healthy animals were offset using descriptive statistics. The diagnostic ability of the test to identify fetal malformations was studied using receiver operating characteristic curve analysis. Of the 26 litters, only 18 had healthy fetuses, 4 had fetuses with anasarca, 3 had fetuses with abdominal wall defects, and 1 had both types of abnormalities. The NT was higher in canine fetuses that presented anasarca in the litter than in normal litters (1.8 ± 0.77 mm vs. 1.4 ± 0.48 mm; P = 0.0249), with a cut-off value of NT > 1.45 mm (sensitivity = 61.54%, specificity = 70.18%). NT greater than 1.45 mm seems to be a diagnostic tool for the identification of anasarca during gestation of bulldogs. Considering the unprecedented use of this parameter in canine species and the limitations found during the study, further studies will be needed in order to use it on clinical practice.

11.
R. bras. Reprod. Anim. ; 45(1): 3-11, jan.-mar. 2021. ilus
Artigo em Inglês | VETINDEX | ID: vti-763426

Resumo

The ultrasonographic exam is of great value in animal reproduction and veterinary obstetrics, because it allows gestational diagnosis and monitoring, as well as the evaluation of the female reproductive system, providing diagnosis of the reproductive state and estrous phase of females. One of the techniques that has been employed in the field of theriogenology is the Doppler Mode, which allows qualitative and quantitative evaluation of the hemodynamics of reproductive organs. Several studies were carried out in attempt to elucidate the ultrasonographic aspect of the uterus and ovaries of bitches during the different phases of the estrous cycle in B mode and Doppler mode. The objective of the present study is to review the information present in the literature regarding the sonographic changes of the reproductive organs of bitches during the different hormonal phases.(AU)


O exame ultrassonográfico tem grande importância na reprodução animal e obstetrícia veterinária, pois permite o diagnóstico e acompanhamento gestacional, bem como a avaliação do sistema reprodutor, proporcionando o diagnóstico do status reprodutivo e fase do ciclo estral. Uma das técnicas ultrassonográficas que vêm sendo empregadas no ramo da teriogenologia é o modo Doppler, que permite avaliações qualitativas e quantitativas da hemodinâmica dos órgãos da reprodução. Diversos estudos foram realizados na tentativa de elucidar o aspecto ultrassonográfico do útero e dos ovários das cadelas durante as diferentes fases do ciclo estral ao modo-B e ao modo Doppler. O presente trabalho tem como objetivo revisar as informações presentes na literatura a respeito das mudanças ultrassonográficas dos órgãos reprodutores da cadela durante as diferentes fases hormonais.(AU)


Assuntos
Animais , Feminino , Cães , Cães/anatomia & histologia , Cães/fisiologia , Útero , Ovário , Ciclo Estral , Hemodinâmica
12.
Anim. Reprod. ; 18(4): e20210023, 2021. tab, graf, ilus
Artigo em Inglês | VETINDEX | ID: vti-32763

Resumo

The aim of this study was to measure the nuchal translucency (NT) of canine fetuses to establish reference values ​​for healthy gestational processes and to verify its effectiveness in the diagnosis of congenital abnormalities. On day 34 of gestation, the NT of three fetuses from each of the 26 English bulldog female dogs was measured. The first fetus was the one located immediately cranial to the bladder, the second was selected from the left side of the abdomen, and the third from the right side. The reference values for healthy animals were offset using descriptive statistics. The diagnostic ability of the test to identify fetal malformations was studied using receiver operating characteristic curve analysis. Of the 26 litters, only 18 had healthy fetuses, 4 had fetuses with anasarca, 3 had fetuses with abdominal wall defects, and 1 had both types of abnormalities. The NT was higher in canine fetuses that presented anasarca in the litter than in normal litters (1.8 ± 0.77 mm vs. 1.4 ± 0.48 mm; P = 0.0249), with a cut-off value of NT > 1.45 mm (sensitivity = 61.54%, specificity = 70.18%). NT greater than 1.45 mm seems to be a diagnostic tool for the identification of anasarca during gestation of bulldogs. Considering the unprecedented use of this parameter in canine species and the limitations found during the study, further studies will be needed in order to use it on clinical practice.(AU)


Assuntos
Animais , Feminino , Gravidez , Cães , Cães/embriologia , Ultrassonografia , Medição da Translucência Nucal/veterinária , Feto
13.
Pesqui. vet. bras ; 41: e06785, 2021. tab, ilus
Artigo em Inglês | VETINDEX | ID: vti-32489

Resumo

The objective of this study was to verify the applicability of B-mode ultrasonography, ARFI elastography and CEUS in the diagnosis of chronic kidney disease and its Stages in dogs. 24 healthy dogs and 28 with CKD were included. In B-mode, the echogenicity, echotexture and cortico-medullary ratio of the kidneys were verified. By elastography, the shear-wave velocity of the cortical (SWVcort) and medullary (SWVmed) regions were determined and tissue deformity was evaluated. Wash-in, wash-out and peak enhancement (TPic) of the contrast in the renal parenchyma were calculated and homogeneity, presence of filling gaps and distinction of filling phases were evaluated by CEUS. Changes in echogenicity, echotexture and cortico-medullary ratio were observed only in sick patients. There was an increase in SWVcort in CKD, with a cutoff point >2.91m/s. Healthy kidneys were non-deformable and 25% had changes in gray scales. There was an increase in wash-in and TPic, changes in filling characteristics, filling failures and difficulty in distinguishing between the Stages in CEUS in CKD. It was found that dogs with CKD 2, 3 and 4 had greater SWVcort and wash-in values than CKD 1. Elastographic and CEUS changes were observed in dogs with CKD, demonstrating the applicability of ultrasonographic techniques in their diagnosis.(AU)


O objetivo deste estudo foi verificar a aplicabilidade da ultrassonografia modo-B, elastografia ARFI e CEUS no diagnóstico da doença renal crônica e seus estágios em cães. Foram incluídos 24 cães saudáveis e 28 com DRC. Pelo modo-B, verificou-se ecogenicidade, ecotextura e relação córtico-medular dos rins. Pela elastografia, foram determinadas as velocidades de cisalhamento das regiões cortical (SWVcort) e medular (SWVmed) e foi avaliada a deformidade tecidual. Calculou-se os temos de wash-in, wash-out e pico de intensidade (TPic) do parênquima renal e avaliou-se homogeneidade, presença de falhas e distinção das fases de preenchimento por contraste por meio de CEUS. Alterações em ecogenicidade, ecotextura e relação córtico-medular foram observadas somente em pacientes doentes. Houve aumento da SWVcort na DRC, com ponto de corte >2.91m/s. Rins saudáveis foram não-deformáveis e 25% apresentou alterações nas escalas de cinza. Houve aumento do wash-in e TPic, alterações nas características de preenchimento, falhas e dificuldade para distinguir as fases de preenchimento do contraste nos rins com DRC. Verificou-se que cães com DRC graus 2, 3 e 4 tiveram valores de SWVcort e wash-in maiores que cães com DRC grau 1. Foram obsrervadas alterações elastográfica e de CEUS em cães com DRC, demonstrando a aplicabilidade destas técnicas ultrassonográficas no seu diagnóstico.(AU)


Assuntos
Animais , Cães , Anormalidades Congênitas , Ultrassonografia , Insuficiência Renal Crônica , Técnicas de Imagem por Elasticidade , Perfusão , Rim
14.
Pesqui. vet. bras ; 41: e06650, 2021. tab, graf, ilus
Artigo em Inglês | VETINDEX | ID: vti-31623

Resumo

The objective of the present study was to obtain echobiometric values for the most important canine maternal-fetal tissues using high-definition ultrasonography (HDUS) trying to update the formulas for predicting gestational age. Twelve healthy bitches of brachycephalic breeds weighing 7-13kg and aged one to four years were included. The fetuses were analyzed every day using conventional and high-definition ultrasonography from the eighth day after artificial insemination until the day of delivery, using the ACUSON S2000/SIEMENS ultrasound equipment and specific software. Embryonic and fetal structures; diameter of the embryonic vesicle; length of the embryo; biparietal diameter, abdominal length and kidney height; length of the femur, humerus, scapula, radius, and tibia; thickening of the stomach wall; adrenal length; and cardiac size were measured. These variables were correlated with gestational and adjusted tested according to regression models. The results obtained (P<0.001) for: lateral diameter of the gestational sac (R2=81.8%); length of the embryo (R2=85.7%); biparietal (R2=99.1%) and abdominal diameter (R2=97.2%); thickness of the gastric wall (R2=86.9%); length of the femur (R2=96.6%), radius (R2=97.5%), humerus (R2=96.5%), scapula (R2=95.8%) and tibia (R2=97.3%); kidney length (R2=95.8%) and height (R2=96.0%); adrenal length (R2=89.6%); heart length (R2=93.0%) and height (R2=91.5%) of the canine fetuses showed significant correlation with gestational days. This allowed monitoring fetal growth and estimation of age with high accuracy in different gestational periods.(AU)


O objetivo do presente estudo foi obter valores ecobiométricos para os tecidos materno-fetais caninos, usando a ultrassonografia de alta definição (HDUS), desenvolvendo fórmulas para prever a idade gestacional das cadelas. Doze cadelas saudáveis de raças braquicefálicas pesando 7-13kg e com idades entre um e quatro anos foram incluídas. Os fetos foram analisados diariamente com ultrassonografia convencional e de alta definição, do oitavo dia após a inseminação artificial até o dia do parto, utilizando o equipamento de ultrassom ACUSON S2000/SIEMENS e software específico. Estruturas embrionárias e fetais; diâmetro da vesícula embrionária; comprimento do embrião; diâmetro biparietal, comprimento abdominal e altura renal; comprimento do fêmur, úmero, escápula, rádio e tíbia; espessamento da parede do estômago; comprimento adrenal; e tamanho cardíaco foram medidos. Essas variáveis foram correlacionadas com o teste gestacional e ajustado de acordo com os modelos de regressão. Os resultados obtidos (P<0,001) para: diâmetro lateral do saco gestacional (R2=81,8%); comprimento do embrião (R2=85,7%); diâmetro biparietal (R2=99,1%) e abdominal (R2=97,2%); espessura da parede gástrica (R2=86,9%); comprimento do fêmur (R2=96,6%), rádio (R2=97,5%), úmero (R2=96,5%), escápula (R2=95,8%) e tíbia (R2=97,3%); comprimento do rim (R2=95,8%) e altura (R2=96,0%); comprimento adrenal (R2=89,6%); o comprimento do coração (R2=93,0%) e a altura (R2=91,5%) dos fetos caninos apresentaram correlação significativa com os dias gestacionais. Isso permitiu monitorar o crescimento fetal e estimar a idade com alta precisão em diferentes períodos gestacionais.(AU)


Assuntos
Animais , Feminino , Cães , Biometria/métodos , Ultrassonografia , Craniossinostoses , Dente Canino , Desenvolvimento Fetal , Inseminação Artificial , Parto
15.
Pesqui. vet. bras ; 41: e06650, 2021. tab, graf, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1250482

Resumo

The objective of the present study was to obtain echobiometric values for the most important canine maternal-fetal tissues using high-definition ultrasonography (HDUS) trying to update the formulas for predicting gestational age. Twelve healthy bitches of brachycephalic breeds weighing 7-13kg and aged one to four years were included. The fetuses were analyzed every day using conventional and high-definition ultrasonography from the eighth day after artificial insemination until the day of delivery, using the ACUSON S2000/SIEMENS ultrasound equipment and specific software. Embryonic and fetal structures; diameter of the embryonic vesicle; length of the embryo; biparietal diameter, abdominal length and kidney height; length of the femur, humerus, scapula, radius, and tibia; thickening of the stomach wall; adrenal length; and cardiac size were measured. These variables were correlated with gestational and adjusted tested according to regression models. The results obtained (P<0.001) for: lateral diameter of the gestational sac (R2=81.8%); length of the embryo (R2=85.7%); biparietal (R2=99.1%) and abdominal diameter (R2=97.2%); thickness of the gastric wall (R2=86.9%); length of the femur (R2=96.6%), radius (R2=97.5%), humerus (R2=96.5%), scapula (R2=95.8%) and tibia (R2=97.3%); kidney length (R2=95.8%) and height (R2=96.0%); adrenal length (R2=89.6%); heart length (R2=93.0%) and height (R2=91.5%) of the canine fetuses showed significant correlation with gestational days. This allowed monitoring fetal growth and estimation of age with high accuracy in different gestational periods.(AU)


O objetivo do presente estudo foi obter valores ecobiométricos para os tecidos materno-fetais caninos, usando a ultrassonografia de alta definição (HDUS), desenvolvendo fórmulas para prever a idade gestacional das cadelas. Doze cadelas saudáveis de raças braquicefálicas pesando 7-13kg e com idades entre um e quatro anos foram incluídas. Os fetos foram analisados diariamente com ultrassonografia convencional e de alta definição, do oitavo dia após a inseminação artificial até o dia do parto, utilizando o equipamento de ultrassom ACUSON S2000/SIEMENS e software específico. Estruturas embrionárias e fetais; diâmetro da vesícula embrionária; comprimento do embrião; diâmetro biparietal, comprimento abdominal e altura renal; comprimento do fêmur, úmero, escápula, rádio e tíbia; espessamento da parede do estômago; comprimento adrenal; e tamanho cardíaco foram medidos. Essas variáveis foram correlacionadas com o teste gestacional e ajustado de acordo com os modelos de regressão. Os resultados obtidos (P<0,001) para: diâmetro lateral do saco gestacional (R2=81,8%); comprimento do embrião (R2=85,7%); diâmetro biparietal (R2=99,1%) e abdominal (R2=97,2%); espessura da parede gástrica (R2=86,9%); comprimento do fêmur (R2=96,6%), rádio (R2=97,5%), úmero (R2=96,5%), escápula (R2=95,8%) e tíbia (R2=97,3%); comprimento do rim (R2=95,8%) e altura (R2=96,0%); comprimento adrenal (R2=89,6%); o comprimento do coração (R2=93,0%) e a altura (R2=91,5%) dos fetos caninos apresentaram correlação significativa com os dias gestacionais. Isso permitiu monitorar o crescimento fetal e estimar a idade com alta precisão em diferentes períodos gestacionais.(AU)


Assuntos
Animais , Feminino , Cães , Biometria/métodos , Ultrassonografia , Craniossinostoses , Dente Canino , Desenvolvimento Fetal , Inseminação Artificial , Parto
16.
Pesqui. vet. bras ; 41: e06785, 2021. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1250490

Resumo

The objective of this study was to verify the applicability of B-mode ultrasonography, ARFI elastography and CEUS in the diagnosis of chronic kidney disease and its Stages in dogs. 24 healthy dogs and 28 with CKD were included. In B-mode, the echogenicity, echotexture and cortico-medullary ratio of the kidneys were verified. By elastography, the shear-wave velocity of the cortical (SWVcort) and medullary (SWVmed) regions were determined and tissue deformity was evaluated. Wash-in, wash-out and peak enhancement (TPic) of the contrast in the renal parenchyma were calculated and homogeneity, presence of filling gaps and distinction of filling phases were evaluated by CEUS. Changes in echogenicity, echotexture and cortico-medullary ratio were observed only in sick patients. There was an increase in SWVcort in CKD, with a cutoff point >2.91m/s. Healthy kidneys were non-deformable and 25% had changes in gray scales. There was an increase in wash-in and TPic, changes in filling characteristics, filling failures and difficulty in distinguishing between the Stages in CEUS in CKD. It was found that dogs with CKD 2, 3 and 4 had greater SWVcort and wash-in values than CKD 1. Elastographic and CEUS changes were observed in dogs with CKD, demonstrating the applicability of ultrasonographic techniques in their diagnosis.(AU)


O objetivo deste estudo foi verificar a aplicabilidade da ultrassonografia modo-B, elastografia ARFI e CEUS no diagnóstico da doença renal crônica e seus estágios em cães. Foram incluídos 24 cães saudáveis e 28 com DRC. Pelo modo-B, verificou-se ecogenicidade, ecotextura e relação córtico-medular dos rins. Pela elastografia, foram determinadas as velocidades de cisalhamento das regiões cortical (SWVcort) e medular (SWVmed) e foi avaliada a deformidade tecidual. Calculou-se os temos de wash-in, wash-out e pico de intensidade (TPic) do parênquima renal e avaliou-se homogeneidade, presença de falhas e distinção das fases de preenchimento por contraste por meio de CEUS. Alterações em ecogenicidade, ecotextura e relação córtico-medular foram observadas somente em pacientes doentes. Houve aumento da SWVcort na DRC, com ponto de corte >2.91m/s. Rins saudáveis foram não-deformáveis e 25% apresentou alterações nas escalas de cinza. Houve aumento do wash-in e TPic, alterações nas características de preenchimento, falhas e dificuldade para distinguir as fases de preenchimento do contraste nos rins com DRC. Verificou-se que cães com DRC graus 2, 3 e 4 tiveram valores de SWVcort e wash-in maiores que cães com DRC grau 1. Foram obsrervadas alterações elastográfica e de CEUS em cães com DRC, demonstrando a aplicabilidade destas técnicas ultrassonográficas no seu diagnóstico.(AU)


Assuntos
Animais , Cães , Anormalidades Congênitas , Ultrassonografia , Insuficiência Renal Crônica , Técnicas de Imagem por Elasticidade , Perfusão , Rim
17.
Rev. bras. reprod. anim ; 45(1): 3-11, jan.-mar. 2021. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1492633

Resumo

The ultrasonographic exam is of great value in animal reproduction and veterinary obstetrics, because it allows gestational diagnosis and monitoring, as well as the evaluation of the female reproductive system, providing diagnosis of the reproductive state and estrous phase of females. One of the techniques that has been employed in the field of theriogenology is the Doppler Mode, which allows qualitative and quantitative evaluation of the hemodynamics of reproductive organs. Several studies were carried out in attempt to elucidate the ultrasonographic aspect of the uterus and ovaries of bitches during the different phases of the estrous cycle in B mode and Doppler mode. The objective of the present study is to review the information present in the literature regarding the sonographic changes of the reproductive organs of bitches during the different hormonal phases.


O exame ultrassonográfico tem grande importância na reprodução animal e obstetrícia veterinária, pois permite o diagnóstico e acompanhamento gestacional, bem como a avaliação do sistema reprodutor, proporcionando o diagnóstico do status reprodutivo e fase do ciclo estral. Uma das técnicas ultrassonográficas que vêm sendo empregadas no ramo da teriogenologia é o modo Doppler, que permite avaliações qualitativas e quantitativas da hemodinâmica dos órgãos da reprodução. Diversos estudos foram realizados na tentativa de elucidar o aspecto ultrassonográfico do útero e dos ovários das cadelas durante as diferentes fases do ciclo estral ao modo-B e ao modo Doppler. O presente trabalho tem como objetivo revisar as informações presentes na literatura a respeito das mudanças ultrassonográficas dos órgãos reprodutores da cadela durante as diferentes fases hormonais.


Assuntos
Feminino , Animais , Cães , Ciclo Estral , Cães/anatomia & histologia , Cães/fisiologia , Hemodinâmica , Ovário , Útero
18.
Acta cir. bras ; 36(12): e361203, 2021. tab, graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1355569

Resumo

ABSTRACT Purpose: To evaluate whether using platelet-rich plasma (PRP) in the graft recipient bed after the resection of a neoplasia can influence its recurrence because this product stimulates angiogenesis, mitogenesis and chemotaxis. Methods: A study with 30 rats Wistar (Rattus norvegicus albinus), which were separated into group A (induction of carcinogenesis, PRP in the postoperative period) and group B (induction of carcinogenesis, absence of PRP in the postoperative period), with 15 animals in each. Carcinogenesis was induced on the skin of the animals' chest by the topical application of 0.5% dimethylbenzantracene (DMBA) diluted in acetone. After surgical resection of the induced neoplasia, PRP was used to stimulate angiogenesis before surgical wound synthesis. Data on the control and experimental groups and macroscopic and microscopic variables were evaluated using analysis of variance and the Tukey's test (5%). Results: It was possible to determine that the use of PRP is good in reconstructive surgeries, but it is contraindicated in patients during tumor resection, as it can cause changes in the surgical bed, in addition to stimulating recurrences and metastases. Conclusions: PRP may interact with tumour cells that were in the recipient site of the surgical wound during the resection of a neoplasia, and a local recurrence process can be triggered by applying this product.


Assuntos
Animais , Ratos , Neoplasias Cutâneas/cirurgia , Neoplasias Cutâneas/induzido quimicamente , Plasma Rico em Plaquetas , Cicatrização , Transplante de Pele , Ratos Wistar
19.
R. bras. Reprod. Anim. ; 43(3): 765-771, jul.-set. 2019.
Artigo em Português | VETINDEX | ID: vti-24479

Resumo

A parturição prematura é fator relevante para a morbidade e mortalidade perinatal em humanos e a determinação da maturidade fetal é de extrema importância, principalmente em gestações de alto risco relacionadas à prematuridade. Em virtude dos estágios de desenvolvimento dos órgãos, em relação ao nascimento, serem semelhantes em ovinos e humanos, a espécie ovina tem sido utilizada como modelo experimental para estudos sobre a maturidade tecidual em conceptos, bem como para emprego de terapias pré-natais (corticosteróides) e suas respostas neste processo. Uma das técnicas que podem ser utilizadas para avaliação do desenvolvimento dos tecidos materno-fetais ovinos é a ultrassonografia, método seguro e não invasivo que fornece informações importantes quanto a maturidade fetal e aspectos maternos que podem contribuir para a determinação do momento do parto e consequente redução da morbidade e mortalidade neonatal em ovinos. Deste modo, esta revisão objetiva descrever aspectos fisiológicos maternos e fetais das últimas semanas gestacionais até o momento do parto em ovinos, assim como mostrar as diferentes técnicas ultrassonográficas utilizadas para a avaliação destas características, afim de auxiliar na identificação de um parto prematuro e/ou gestações de alto risco.(AU)


Premature birth is a relevant factor for perinatal morbidity and mortality in humans and the determination of fetal maturity is extremely important, especially in high-risk pregnancies related to prematurity. Because the stages of organ development in relation to birth are similar in sheep and humans, the ovine species has been used as an experimental model for studies on fetal tissue maturity, as well as for the use of prenatal therapies (corticosteroids) and its action during this process. One technique that can be used to evaluate the development of ovine maternal and fetal tissues is the ultrasound, wich is a safe and noninvasive method that provides important information about the moment of delivery, aids the determination of fetal maturity, the diagnosis of possible premature birth and consequently contributes to the reduction of neonatal morbidity and mortality. This review aims to describe the physiological aspects of the last gestational weeks until delivery, as well as to show the different ultrasound techniques used to assess fetal maturity in order to assist the identification of premature delivery and/or high risk pregnancies.(AU)


Assuntos
Animais , Feminino , Gravidez , Ovinos/embriologia , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/veterinária , Ultrassonografia/veterinária , Parto
20.
Rev. bras. reprod. anim ; 43(3): 765-771, jul.-set. 2019.
Artigo em Português | VETINDEX | ID: biblio-1492593

Resumo

A parturição prematura é fator relevante para a morbidade e mortalidade perinatal em humanos e a determinação da maturidade fetal é de extrema importância, principalmente em gestações de alto risco relacionadas à prematuridade. Em virtude dos estágios de desenvolvimento dos órgãos, em relação ao nascimento, serem semelhantes em ovinos e humanos, a espécie ovina tem sido utilizada como modelo experimental para estudos sobre a maturidade tecidual em conceptos, bem como para emprego de terapias pré-natais (corticosteróides) e suas respostas neste processo. Uma das técnicas que podem ser utilizadas para avaliação do desenvolvimento dos tecidos materno-fetais ovinos é a ultrassonografia, método seguro e não invasivo que fornece informações importantes quanto a maturidade fetal e aspectos maternos que podem contribuir para a determinação do momento do parto e consequente redução da morbidade e mortalidade neonatal em ovinos. Deste modo, esta revisão objetiva descrever aspectos fisiológicos maternos e fetais das últimas semanas gestacionais até o momento do parto em ovinos, assim como mostrar as diferentes técnicas ultrassonográficas utilizadas para a avaliação destas características, afim de auxiliar na identificação de um parto prematuro e/ou gestações de alto risco.


Premature birth is a relevant factor for perinatal morbidity and mortality in humans and the determination of fetal maturity is extremely important, especially in high-risk pregnancies related to prematurity. Because the stages of organ development in relation to birth are similar in sheep and humans, the ovine species has been used as an experimental model for studies on fetal tissue maturity, as well as for the use of prenatal therapies (corticosteroids) and its action during this process. One technique that can be used to evaluate the development of ovine maternal and fetal tissues is the ultrasound, wich is a safe and noninvasive method that provides important information about the moment of delivery, aids the determination of fetal maturity, the diagnosis of possible premature birth and consequently contributes to the reduction of neonatal morbidity and mortality. This review aims to describe the physiological aspects of the last gestational weeks until delivery, as well as to show the different ultrasound techniques used to assess fetal maturity in order to assist the identification of premature delivery and/or high risk pregnancies.


Assuntos
Feminino , Animais , Gravidez , Ovinos/embriologia , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/veterinária , Ultrassonografia/veterinária , Parto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA