Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Arq. bras. med. vet. zootec. (Online) ; 74(5): 948-953, Sep.-Oct. 2022. tab, ilus
Artigo em Inglês | VETINDEX | ID: biblio-1403408

Resumo

The aim of this study was to develop a modified tibial plateau leveling osteotomy (TPLO) plate and to compare its biomechanical properties with a locking compression plate (LCP) and plate-rod constructs for the stabilization of experimentally induced gap fractures in canine synthetic tibias. The tibial models were assigned to either repair with a modified TPLO plate (Group 1), locking compression plate construct (Group 2), or plate-rod construct (Group 3). The specimens were loaded to failure in axial compression, three-point mediolateral and craniocaudal bending. There was no statistical difference between the three groups regarding stiffness (N/mm) and deformation (mm) in axial compression. The modified TPLO plate achieved load to failure similar to the plate-rod construct in craniocaudal bending. There was no significant difference between groups on mediolateral bending tests regarding load to failure and deformation. Furthermore, there was no significant difference in stiffness between groups 1 and 2. In conclusion, the modified TPLO plate had similar mechanical properties to LCP and plate-rod construct in the axial compression and bending tests. Nonetheless, clinical studies with a large population of dogs are required to determine the value of this new implant in proximal tibial fracture repair.


Objetivou-se desenvolver uma placa de osteotomia niveladora do platô tibial (TPLO) modificada e compará-la biomecanicamente à placa de compressão bloqueada (LCP) e à construção placa-pino intramedular na estabilização da fratura cominutiva proximal em tíbias sintéticas caninas. Para tal, tíbias caninas sintéticas foram divididas em três grupos, sendo o grupo 1 formado pela placa de TPLO modificada, o grupo 2 por placas LCP e o grupo 3 pela construção placa-pino intramedular. Os espécimes foram submetidos à carga até a falha em compressão axial, flexão mediolateral e craniocaudal em três pontos. Não houve diferença estatística entre os três grupos quanto à rigidez (N/mm) e à deformação (mm) nos testes de compressão axial. A placa de TPLO modificada obteve carga até a falha semelhante à construção placa-pino intramedular em flexão craniocaudal. Não houve diferença significativa entre os grupos nos testes de flexão mediolateral em relação à carga até a falha e a deformação, e a variável rigidez não apresentou diferenças significativas entre os grupos 1 e 2. Em conclusão, a placa de TPLO modificada apresentou similaridade mecânica em comparação com a LCP e a construção placa-pino. No entanto, estudos clínicos são necessários para determinar o valor desse novo implante na fixação de fraturas tibiais proximais.


Assuntos
Osteotomia/veterinária , Fraturas da Tíbia/cirurgia , Placas Ósseas/veterinária , Fenômenos Biomecânicos
2.
Arq. bras. med. vet. zootec. (Online) ; 71(5): 1535-1540, set.-out. 2019. ilus, graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1038647

Resumo

The objective of this study was to develop a locked tibial-plateau-leveling osteotomy (TPLO) plate and to compare this implant with the conventional bone fixation method using a locked plate to determine bone stabilization against torsion forces. Maximum force, angle at peak torque, and stiffness values were determined. Ten synthetic tibias were used, divided into 2 groups. The results in Group 1 (modified TPLO plate) and Group 2 (locked plate) were assessed using analysis of variance and the means were compared using Tukey's test at 5% probability. There were significant differences in the angle at peak torque and stiffness. The group Modified TPLO plate had higher mean values of stiffness compared with Group locked plate. Group locked plate showed a greater angle at peak torque compared with Group modified TPLO plate. All constructs failed due to tibial fractures distal to the plate. The modified TPLO plate presented higher stiffness indexes than conventional locked plate in torsion. The locked plate presented greater elasticity than modified TPLO plate having greater angle at the peak of torque.(AU)


O objetivo do presente estudo foi desenvolver placa de TPLO bloqueada modificada e avaliar, em ensaio de torção, a estabilização óssea proporcionada pelo implante desenvolvido comparativamente a método de fixação óssea convencional com placa reta bloqueada. As variáveis obtidas foram força máxima, ângulo no pico de torque e rigidez. Foram utilizadas 10 tíbias sintéticas, dividas em dois grupos. Os resultados obtidos do grupo 1 (placa TPLO modificada) e do grupo 2 (placa bloqueada) foram submetidos à análise de variância, e as médias comparadas entre si pelo teste de Tukey a 5% de probabilidade. Houve diferença significativa em relação às variáveis, ângulo no pico de torque e rigidez. Na variável rigidez, a média do grupo placa de TPLO modificada foi maior que a do grupo placa reta bloqueada. Em relação à variável ângulo no pico de torque, o grupo placa reta bloqueada foi superior ao grupo placa de TPLO modificada. Todas as montagens falharam devido à quebra do corpo de prova distal à placa. Conclui-se que a placa de TPLO modificada apresentou maior índice de rigidez que a placa reta convencional sob força de torção. A placa reta bloqueada apresentou maior ângulo no pico de torque, sendo, portando, mais elástica.(AU)


Assuntos
Animais , Cães , Próteses e Implantes/veterinária , Procedimentos Ortopédicos/veterinária , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/veterinária , Tíbia
3.
Arq. bras. med. vet. zootec. (Online) ; 71(5): 1535-1540, set.-out. 2019. ilus, graf
Artigo em Inglês | VETINDEX | ID: vti-25293

Resumo

The objective of this study was to develop a locked tibial-plateau-leveling osteotomy (TPLO) plate and to compare this implant with the conventional bone fixation method using a locked plate to determine bone stabilization against torsion forces. Maximum force, angle at peak torque, and stiffness values were determined. Ten synthetic tibias were used, divided into 2 groups. The results in Group 1 (modified TPLO plate) and Group 2 (locked plate) were assessed using analysis of variance and the means were compared using Tukey's test at 5% probability. There were significant differences in the angle at peak torque and stiffness. The group Modified TPLO plate had higher mean values of stiffness compared with Group locked plate. Group locked plate showed a greater angle at peak torque compared with Group modified TPLO plate. All constructs failed due to tibial fractures distal to the plate. The modified TPLO plate presented higher stiffness indexes than conventional locked plate in torsion. The locked plate presented greater elasticity than modified TPLO plate having greater angle at the peak of torque.(AU)


O objetivo do presente estudo foi desenvolver placa de TPLO bloqueada modificada e avaliar, em ensaio de torção, a estabilização óssea proporcionada pelo implante desenvolvido comparativamente a método de fixação óssea convencional com placa reta bloqueada. As variáveis obtidas foram força máxima, ângulo no pico de torque e rigidez. Foram utilizadas 10 tíbias sintéticas, dividas em dois grupos. Os resultados obtidos do grupo 1 (placa TPLO modificada) e do grupo 2 (placa bloqueada) foram submetidos à análise de variância, e as médias comparadas entre si pelo teste de Tukey a 5% de probabilidade. Houve diferença significativa em relação às variáveis, ângulo no pico de torque e rigidez. Na variável rigidez, a média do grupo placa de TPLO modificada foi maior que a do grupo placa reta bloqueada. Em relação à variável ângulo no pico de torque, o grupo placa reta bloqueada foi superior ao grupo placa de TPLO modificada. Todas as montagens falharam devido à quebra do corpo de prova distal à placa. Conclui-se que a placa de TPLO modificada apresentou maior índice de rigidez que a placa reta convencional sob força de torção. A placa reta bloqueada apresentou maior ângulo no pico de torque, sendo, portando, mais elástica.(AU)


Assuntos
Animais , Cães , Próteses e Implantes/veterinária , Procedimentos Ortopédicos/veterinária , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/veterinária , Tíbia
4.
Arq. bras. med. vet. zootec. (Online) ; 70(3): 661-666, maio-jun. 2018. ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-911017

Resumo

This study aims to report the technique of partial cystectomy and bilateral ureteral reimplantation for resection of transitional cell carcinoma (TCC) in the trigone region of the bladder and the long-term follow-up in a Bernesse Mountain dog. The proposed surgical technique was considered viable and a potential treatment option for TCC in bladder trigone, with benefits regarding the prevention of urinary tract obstruction due to neoplastic growth and local removal of the primary tumor, which may limit or delay the spread of the disease even without adjuvant chemotherapy. The main disadvantages related to the described technique are ureteral stricture, intermittent cystitis and local relapse. However, the results are acceptable considering the long-term survival of 610 days in the case described.(AU)


Esse estudo tem como objetivo relatar a técnica de cistectomia parcial e reimplantação uretral bilateral para ressecção de carcinoma de células de transição em região trigonal de bexiga e seguimento clínico de cão da raça Bernesse Mountain. A técnica cirúrgica proposta foi considerada viável e opção potencial de tratamento com benefícios na prevenção de obstrução de trato uretral devido a crescimento neoplásico e remoção local de tumor primário que pode limitar ou retardar a disseminação da doença mesmo sem quimioterapia adjuvante. A principal desvantagem relatada em relação à técnica descrita são constrição uretral, cistite intermitente, e relapso local. No entanto, os resultados são aceitáveis levando em consideração a sobrevida a longo prazo de 610 no caso descrito.(AU)


Assuntos
Animais , Cães , Carcinoma/veterinária , Cistectomia/classificação , Cistectomia/normas
5.
Arq. bras. med. vet. zootec. (Online) ; 70(3): 661-666, Maio-Jun. 2018. ilus
Artigo em Inglês | VETINDEX | ID: vti-735103

Resumo

This study aims to report the technique of partial cystectomy and bilateral ureteral reimplantation for resection of transitional cell carcinoma (TCC) in the trigone region of the bladder and the long-term follow-up in a Bernesse Mountain dog. The proposed surgical technique was considered viable and a potential treatment option for TCC in bladder trigone, with benefits regarding the prevention of urinary tract obstruction due to neoplastic growth and local removal of the primary tumor, which may limit or delay the spread of the disease even without adjuvant chemotherapy. The main disadvantages related to the described technique are ureteral stricture, intermittent cystitis and local relapse. However, the results are acceptable considering the long-term survival of 610 days in the case described.(AU)


Esse estudo tem como objetivo relatar a técnica de cistectomia parcial e reimplantação uretral bilateral para ressecção de carcinoma de células de transição em região trigonal de bexiga e seguimento clínico de cão da raça Bernesse Mountain. A técnica cirúrgica proposta foi considerada viável e opção potencial de tratamento com benefícios na prevenção de obstrução de trato uretral devido a crescimento neoplásico e remoção local de tumor primário que pode limitar ou retardar a disseminação da doença mesmo sem quimioterapia adjuvante. A principal desvantagem relatada em relação à técnica descrita são constrição uretral, cistite intermitente, e relapso local. No entanto, os resultados são aceitáveis levando em consideração a sobrevida a longo prazo de 610 no caso descrito.(AU)


Assuntos
Animais , Cães , Carcinoma/veterinária , Cistectomia/classificação , Cistectomia/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA