Resumo
Background: In people, extrarenal pelvis is a normal anatomical variant, characterized by the protusion of the pelvis out of the renal hilum, which can be associated with other anomalies, or predispose to stasis or infection. While other diagnostic imaging methods provide anatomical and morphological information about the kidney, scintigraphy allows to determine the renal function and has greater sensitivity in the detection of functional alterations. The aim of this work is to report the case of an asymptomatic cat diagnosed with extrarenal pelvis detected by scintigraphy, which presented alterations in laboratory and renal imaging tests, and absence of associated obstructive process. Case: A 7-year-old mixed-breed female cat was evaluated for a routine health assessment at the Veterinary Teaching Hospital of the Federal University of Rio Grande do Sul (HCV-UFRGS). When performing the imaging and laboratory tests, renal alterations compatible with chronic kidney disease were found in the abdominal ultrasonography examination and in serum creatinine levels. Therefore, it was decided to perform scintigraphy evaluation to better assess renal function. Dynamic renal scintigraphy with 99mTcDTPA revealed an evident concentration of the radiotracer in the left kidney with effective elimination only after the diuretic stimulus. The right kidney exhibited less concentration of the radiotracer but showed effective elimination before the diuretic stimulus. Image analysis suggested the presence of an extrarenal pelvis on the left side. The relative renal uptake was 68% for the left kidney and 32% for the right kidney. The glomerular filtration rate was 1.65 mL/min/kg. Static renal scintigraphy with 99mTcDMSA revealed irregularity in the distribution of the radiotracer in both kidneys, showing less activity in the caudal pole of the left kidney. The right kidney was apparently reduced and with less activity, especially in the medial portion. The relative renal uptake was 65% for the left kidney and 35% for right kidney, while the absolute renal uptake of the left kidney was 33% and that of the right kidney was 17%. The alteration described in the left kidney, in correlation with dynamic renal scintigraphy, suggested an aspect of lower activity in the caudal pole due to the presence of activity in the extrarenal pelvis. The left kidney was classified as presenting normal renal function and there was moderate to severe deficit of renal function on the right side. Discussion: Chronic kidney disease may be present before clinical signs and biochemical abnormalities are identified. In this report, the animal was referred for a routine evaluation and showed no clinical signs nor alterations on physical examination. However, as renal morphological alterations were seen on ultrasonography and the cat presented mild azotemia, it was decided to perform two renal scintigraphy exams. Despite the radiotracer elimination from the left kidney was seen only after the diuretic stimulus, dynamic renal scintigraphy did not show any obstructive process. This delay on elimination was probably a result of the anatomical variant called extrarenal pelvis. In the static renal scintigraphy, it was possible to evaluate morphological changes in the kidneys and suggest less activity in the caudal pole of the left kidney, due to the presence of activity in the extrarenal pelvis, apparently causing the mentioned defect. The correct diagnosis of morphological changes is essential and for this purpose the best combination of imaging tests is necessary. Renal scintigraphy was fundamental, in this case, for the diagnosis of extrarenal pelvis in one of the kidneys, an abnormality not reported in the feline species within the literature researched by the authors. In addition, renal scintigraphy helped to guide the clinical management of the patient described in this report.
Assuntos
Animais , Feminino , Gatos , Pelve/anormalidades , Insuficiência Renal Crônica/veterinária , Insuficiência Renal Crônica/diagnóstico por imagem , Cintilografia/veterinária , Compostos Radiofarmacêuticos/administração & dosagemResumo
Cintilografia como auxílio no diagnóstico precoce da doença renal em felinos domésticos
Cintilografia como auxílio no diagnóstico precoce da doença renal em felinos domésticos
Resumo
PURPOSE: Fetal hydronephrosis is a frequent finding due to advances in prenatal ultrasonography. The definition of fetal and neonatal urinary tract obstruction is a very difficult task requiring confirmation of reduced renal function and hydronephrosis. In this study we followed a series of consecutive patients with intrauterine hydronephrosis that persisted during post-natal life. METHODS: 116 newborns with antenatal hydronephrosis diagnosed by ultrasound and submitted to a specific post-natal evaluative protocol with a follow-up period of 6 years. RESULTS: In 45 (38.8%) of 116 patients, ureteropelvic junction (UPJ) obstruction was confirmed and surgical correction of the UPJ obstruction was done in 19 patients. From 26 children who were initially submitted to non-surgical treatment, only 6 (23%) needed a surgical approach during follow up. Overall analysis showed that surgery was performed in 25 patients with UPJ obstruction, and the others 20 patients were kept under clinical observation, since normal renal function was confirmed by scintigraphy scans. CONCLUSION: Fetal hydronephrosis due to UPJ obstruction deserves careful postnatal evaluation. UPJ obstruction is the most frequent anomaly and its surgical treatment has very precise indications. The evaluative protocol was useful in identify patients that could be followed-up with a non-surgical approach.(AU)
OBJETIVO: Com a ampla utilização dos exames ultrassonográficos na avaliação pré-natal, é frequente o diagnóstico da hidronefrose fetal. A definição de obstrução do trato urinário no periodo pós-natal necessita da confirmação de redução da função renal além da hidronefrose. Neste estudo, acompanhamos uma série de pacientes consecutivos com hidronefrose intra-útero que persistiu no periodo pós-natal. MÉTODOS: 116 recém-nascidos com hidronefrose pré-natal diagnosticada pela ultrassonografia foram submetidos a protocolo específico de avaliação e companhados pelo periodo de 06 anos. RESULTADOS: Em 46 (38,8%) dos 116 pacientes foi confirmado o diagnóstico de estenose da junção ureteropiélica (JUP). Conforme os resultados do protocolo aplicado a correção cirúrgica da estenose da JUP foi realizada em 19 pacientes. Das 26 crianças encaminhadas inicialmente para observação clínica, apenas 6 (23%) necessitaram cirurgia durante o seguimento ambulatorial. Na análise geral, o procedimento cirúrgico para correção da estenose da JUP foi indicado em 25 pacientes. Nas outras 20 crianças não houve necessidade da realização da cirurgia. CONCLUSÃO: a hidronefrose fetal requer cuidadosa avaliação pós-natal. A estenose da junção pielo-ureteral é a anomalia mais frequente como causa da hidronefrose, e sua correção cirúrgica tem indicações precisas. O protocolo aplicado foi útil em diferenciar pacientes que não necessitaram cirurgia para tratamento da estenose da JUP.(AU)
Assuntos
Humanos , Animais , Hidronefrose , Útero/anatomia & histologia , Cintilografia , Constrição PatológicaResumo
The objective of this work was to monitor the consolidation of the femur after osteosynthesis with a bridge plate associated with the intramedullary pin using scintigraphy. We used seven New Zealand breed male rabbits, at 4 months of age, with a mean weight of 3.5 kg. We performed a three-phase bone scintigraphy with technetium-labeled methylene diphosphonate (99mTc-MDP) before and after surgery, and 20, 50 and 90 days postoperatively. The activity index (AI) was calculated by dividing the average number of uptake counts in the region of the osteotomy by the average number of counts in the corresponding region in the contralateral limb. Radiography was performed before surgery, after surgery, and 15, 30, 45, 60 and 90 days postoperatively. We found a direct relationship between the activity index and progress of bone scintigraphy in the evaluation sequence over the period of observation. Scintigraphy allows monitoring of bone metabolism and measurement of vascularization and/or bone or tissue perfusion. The images obtained in the blood pool and static phases are the most appropriate for assessing bone metabolism in the context of this study. The bridge plate associated with the intramedullary pin promotes osteosynthesis with sufficient stability to allow bone consolidation.(AU)
A cintilografia foi empregada no acompanhamento da consolidação de osteotomia experimental do fêmur após osteossíntese com placa em ponte associada ao pino intramedular. Foram usados sete coelhos machos, raça Nova Zelândia, com massa corporal de 3,5kg e idade média de quatro meses. A cintilografia óssea trifásica com metilenodifosfonato marcado com tecnécio-99m (MDP-99mTc) foi obtida antes e após a cirurgia, e nos dias 20, 50 e 90 do pós-operatório.O índice de atividade (IA) foi calculado por meio do quociente da média do número de contagens na região da osteotomia pela média do número de contagens na região correspondente, no membro contralateral normal. Paralelamente ao estudo cintilográfico, foram realizadas radiografias antes dos procedimentos cirúrgicos e aos 15, 30, 45, 60 e 90 dias após, para acompanhamento do processo de cura óssea. Encontrou-se relação direta entre o índice de atividade e a evolução do processo de consolidação óssea na avaliação cintilográfica sequencial ao longo do período de observação. A cintilografia óssea trifásica permite acompanhar o metabolismo ósseo, avaliar e mensurar a vascularização e perfusão tecidual. As imagens obtidas na fase de pool sanguíneo e na fase óssea são as mais adequadas para avaliação do metabolismo ósseo. A placa em ponte associada com o pino intramedular promove osteossíntese com estabilidade suficiente para permitir a consolidação ossea.(AU)
Assuntos
Animais , Fixação Interna de Fraturas , Fêmur/anatomia & histologia , Cintilografia , CoelhosResumo
PURPOSE: To examine the possible late complications of splenectomy or spleen autotransplantation in large laboratory animal model, in which we need non-invasive or minimal-invasive methods for long-term monitoring of the experimental animals. METHODS: Experimental groups of beagle dogs were: non-operated control, sham-operated control, splenectomy, spleen autotransplantation with 5 or 10 spleen-chips taken into the greater omentum (Furka's technique). Prior to operations, on the 1st postoperative week, monthly till the 6th as well as in the 9th and 12th month, hemorheological examinations were performed. In postoperative 12th month colloid scintigraphy and diagnostic laparoscopy were carried out. At the end of the investigation comparative morphological examinations were performed, too. RESULTS: From the 4th-5th postoperative month filtration function of spleen-autotransplants showed particular restoration compared to splenectomy group. However, the functional results did not reach the values of the control or sham-operated groups. Sham-operated control's scintigraphy nicely showed activity in the spleen. In spleen autotransplantation-groups scintigraphy indicated well the activity of spleen-chips. During diagnostic laparoscopy spleen-chips with their blood supply were found. Histologically, the structure of spleenautotransplants was similar to normal splenic tissue. CONCLUSIONS: The autotransplants are regenerated, their functions have been partly restored, and thus spleen autotransplantation may prevent the possible complications of splenectomy. These parameters and the presented investigative protocol are suitable for long-term following-up of viability of the spleen-autotransplants.(AU)
OBJETIVO: Examinar as possíveis complicações tardias da esplenectomia ou do autotransplante de baço em modelo animal de grande porte, no qual faz-se necessário o uso de métodos não invasivos ou minimamente invasivos para monitorizar os animais de experimentação. MÉTODOS: Grupos experimentais de cães beagle foram: não-operados controle, sham-operados controle, esplenectomia, autotransplante de baço com 5 ou 10 fatias de baço colocados no grande omento (técnica de Furka). Antes das operações, na 1ª semana de pósoperatório, mensalmente até 6o.assim como no 9º. e 12º. mês, foram realizados exames hemorreológicos. No 12º. mês de pós-operatório, cintilografia colóide e laparoscopia diagnóstica foram realizadas. Ao final do experimento, exames morfológicos comparativos foram realizados também. RESULTADOS: A partir do 4º-5º mês pós-operatório, a função de filtração dos baços autotransplantados mostraram particular restauração comparados ao grupo esplenectomia. Entretanto, os resultados funcionais não alcançaram os valores dos grupos controle ou sham-operados. A cintilografia dos controles sham-operados mostraram atividade no baço. Nos grupos de autotransplante, a cintilografia indicou bem a atividade das fatias de baço. Durante a laparoscopia diagnóstica, as fatias de baço com seu suprimento sanguíneo foram encontrados. Histologicamente, a estrutura dos autotransplantes de baço foi similar ao tecido normal de baço. CONCLUSÕES: Os autotransplantes são regenerados, suas funções foram parcialmente restauradas, e então ao autotransplantate esplênico pode prevenir as possíveis complicações da esplenectomia. Estes parâmetros e o protocolo experimental são adequados para o seguimento em longo prazo da viabilidade de autotransplantes esplênicos.(AU)
Assuntos
Animais , Masculino , Feminino , Cães , Modelos Animais , Baço/transplante , Esplenectomia/efeitos adversos , Coloides , Estudos de Viabilidade , Laparoscopia , Período Pós-Operatório , Regeneração , Baço/fisiologia , Baço , Fatores de Tempo , Transplante Autólogo/efeitos adversos , Transplante Autólogo/métodos , Resultado do TratamentoResumo
PURPOSE: The present a novel adenocarcinoma model in athymic mice. METHODS: Seven athymic mice were used. Colon diversion and distal fistula were made. Adenocarcinoma cells were inoculated in the submucosa of fistula. Tumor growth was monitored daily. Scintigraphy with 99mTc-MIBI was performed to identify the tumor. RESULTS: The model of distal colon cancer is feasible. Tumor detection was possible by both, macroscopically and molecular imaging. All resections demonstrated poorly differentiated tumors. Colon obstruction occurred in one case, similarly to evolution in human tumors of distal colon. CONCLUSION: The proposed model of distal colon cancer is feasible, allows for easy monitoring of tumoral growth by both, macroscopically and molecular imaging, and is suitable for studying the evolution of tumor with implementation of cytotoxic therapy in vivo.(AU)
OBJETIVO: Apresentar novo modelo de adenocarcinoma distal em camundongos atímicos. MÉTODOS: Foram utilizados sete camundongos atímicos. Desvio do cólon distal e fístula foram feitas. Células de adenocarcinoma foram inoculadas na submucosa da fístula. O crescimento do tumor foi monitorado diariamente. Cintilografia com 99mTc-MIBI foi realizada para identificar o tumor. RESULTADOS: O modelo de câncer de cólon distal é viável. Detecção do tumor foi possível macroscopicamente e por imagem molecular. Todas as ressecções demonstraram tumores pouco diferenciados. Obstrução do cólon ocorreu em um caso, de forma semelhante à evolução em tumores humanos do cólon distal. CONCLUSÃO: O modelo de câncer do cólon distal proposto é viável, permite a monitorização fácil do crescimento tumoral macroscopicamente e por imagem molecular, sendo adequado para o estudo da evolução de tumor com aplicação de terapia citotóxica in vivo.(AU)
Assuntos
Animais , Neoplasias do Colo/patologia , Camundongos Nus/classificação , FístulaResumo
Purpose: Angiogenesis involves many mediators including integrins, and the tripeptide RGD is a target amino acid recognition sequence for many of them. Hindlimb ischemia is a simple and convenient animal model however standardization of the injection procedures in the devascularized and control limb is lacking, thus rendering difficult the interpretation of results. The aim of this investigations was to evaluate neovascularization in a hindlimb murine model by means of 99mTc-HYNIC-ß-Ala-RGD. Methods: 99mTc-HYNIC-RGD analog was prepared using coligands. Ischemia was induced in Wistar rats by double- ligation of the common femoral artery. Radiolabeled RGD was injected after 2h, as well as 1, 3, 5, 7, 10 and 14 days. Uptake was evaluated by planar imaging and biodistribution studies. Results: The highest ratio between ischemia and control was achieved at the 7th day (2.62 ± 0.95), with substantial decrease by the 14th day. For pertechnetate the 7th day ratio was 0.87 ± 0.23. Scintigraphic image confirmed different uptakes. Conclusion: 99mTc-HYNIC-RGD analog concentrated in ischemic tissue by the time of widespread angiogenesis and pertechnetate confirmed reduction in blood flow. In this sense, the protocol can be recommended for ischemic models. (AU)
Objetivo: A angiogênese em resposta a fenômenos isquêmicos envolve vários mediadores como as integrinas, sendo que o tripeptídeo RGD possui uma seqüência de aminoácidos com reconhecimento para este alvo. O modelo animal de isquemia de pata traseira é simples e conveniente, porém não há uma padronização do procedimento de injeção e controle radioisotópico em membro desvascularizado, dificultando, portanto a interpretação de resultados. O objetivo deste estudo foi avaliar a neovascularização em modelo murino de isquemia de pata traseira através do radiotraçador 99mTc-HYNIC-ß-Ala-RGD. Métodos: O análogo 99mTc-HYNIC-RGD foi preparado usando coligantes. A isquemia foi induzida em ratos Wistar por dupla-ligação da artéria femoral comum na prega inguinal. Peptídeo RGD radiomarcado foi injetado após 2h, assim como 1, 3, 5, 7, 10 e 14 dias. A captação foi avaliada por imagem planar e estudos de biodistribuição. Resultados: A maior diferença de captação entre isquemia e pata controle foi obtida no 7o dia (2,62 ± 0,95), com decréscimo acentuado no 14o dia. Para o pertecnetato a razão no 7o dia foi 0,87 ± 0,23. A imagem cintilográfica confirmou as diferentes captações. Conclusões: O análogo 99mTc-HYNIC-RGD concentrou-se no tecido isquêmico na etapa em que a angiogênese é mais acentuada, e o estudo do pertecnetato confirmou a redução no fluxo sanguíneo. Desta maneira, este protocolo diagnóstico pode ser recomendado para modelos isquêmicos. (AU)
Assuntos
Animais , Ratos , Cintilografia , Isquemia , RatosResumo
Na rotina clínica de felinos domésticos, algumas modalidades de diagnóstico por imagem, como a ultrassonografia, radiografia simples e urografia excretora, já são amplamente utilizadas. A cintilografia é uma técnica não invasiva, capaz de oferecer informações funcionais de rins individualmente, porém é considerada uma modalidade menos usual. O objetivo deste estudo foi verificar o tempo de excreção renal de felinos domésticos através da cintilografia, em animais com parâmetros ultrassonográficos e radiográficos dentro dos limites da normalidade. Foram utilizados 15 animais, 9 machos e 6 fêmeas, e estes foram divididos em grupos de animais não submetidos à anestesia e anestesiados. Foi estabelecido o tempo para o radiofármaco obter acúmulo máximo em cada um dos rins e o tempo para este acúmulo máximo ser reduzido pela metade. Não houve diferença estatística entre os valores dos animais não-anestesiados e anestesiados, nem entre os rins esquerdo e direito, tampouco entre machos e fêmeas.(AU)
In internal medicine of domestic cats, some imaging diagnosis modalities, such as ultrasonography, radiography and intravenous pylogram are spreadly used. Scintigraphy is a non-invasive technique, which provides functional information of individual kidneys; however, it is regarded not ordinary nowadays. The aim of this study was to verify the time of excretion of each particular kidney in domestic cats by scintigraphy, and these animals were presented with normal ultrasonographic and radiographic parameters. We used 15 cats, 9 males and 6 females, and they were divided into awake and anesthetized cats. We calculated the time the radiopharmaceutical takes to reach the maximum activity in the kidneys (T max.) and the time it takes to decrease into half of this value (half-time). There was no difference between the awake and anesthetized cats, nor between the right and left kidneys, and no difference between male and female either.(AU)
Assuntos
Animais , Masculino , Feminino , Adulto , Gatos , Medicina Nuclear/métodos , Testes de Função Renal/métodos , Testes de Função Renal/veterinária , Transtornos da Excreção , Diagnóstico por Imagem/tendências , Diagnóstico por Imagem/veterinária , Gatos , Doença , RimResumo
Pulmonary function evaluation in dogs can be gotten by scintigraphy exams, which are obtained with radiopharmacs injections, followed by radiography. In this study it was used 10 healthful male dogs of Rottweiler breed, radiographically normal and serum negative for dirofilariasis, with administration of varied doses of human serum albumin grouped marked with technetium-99m (MAA). The results were evaluated qualitatively and quantitatively, considering the index of pulmonary perfusion and its homogeneity, being found an increase on the homogeneity of image directly related with the number of MAA particles injected. This study defines the criteria of normality and the dosage of pulmonary perfusion in healthful dogs established with scintigraphy technique.
A avaliação da função pulmonar em cães pode ser obtida mediante exames cintilográficos, os quais incluem a injeção de radiofármacos, seguida de radiografias. Neste estudo, foram utilizados 10 cães machos hígidos da raça Rottweiler e radiograficamente normais e soronegativos para dirofilariose, com administração de doses variadas de macroagregado de albumina sérica humana marcados com tecnécio-99m ([99mTc](MAA)). Os resultados foram avaliados qualitativa e quantitativamente, considerando o índice de perfusão pulmonar e sua homogeneidade, sendo dessa maneira visualizado um aumento na homogeneidade da imagem diretamente relacionado ao número de partículas de MAA injetado. Este estudo define os critérios de normalidade e de dosagem na perfusão pulmonar em cães hígidos da raça Rottweiller estabelecidos com a técnica de cintilografia.
Resumo
Pulmonary function evaluation in dogs can be gotten by scintigraphy exams, which are obtained with radiopharmacs injections, followed by radiography. In this study it was used 10 healthful male dogs of Rottweiler breed, radiographically normal and serum negative for dirofilariasis, with administration of varied doses of human serum albumin grouped marked with technetium-99m (MAA). The results were evaluated qualitatively and quantitatively, considering the index of pulmonary perfusion and its homogeneity, being found an increase on the homogeneity of image directly related with the number of MAA particles injected. This study defines the criteria of normality and the dosage of pulmonary perfusion in healthful dogs established with scintigraphy technique.
A avaliação da função pulmonar em cães pode ser obtida mediante exames cintilográficos, os quais incluem a injeção de radiofármacos, seguida de radiografias. Neste estudo, foram utilizados 10 cães machos hígidos da raça Rottweiler e radiograficamente normais e soronegativos para dirofilariose, com administração de doses variadas de macroagregado de albumina sérica humana marcados com tecnécio-99m ([99mTc](MAA)). Os resultados foram avaliados qualitativa e quantitativamente, considerando o índice de perfusão pulmonar e sua homogeneidade, sendo dessa maneira visualizado um aumento na homogeneidade da imagem diretamente relacionado ao número de partículas de MAA injetado. Este estudo define os critérios de normalidade e de dosagem na perfusão pulmonar em cães hígidos da raça Rottweiller estabelecidos com a técnica de cintilografia.
Resumo
Pulmonary function evaluation in dogs can be gotten by scintigraphy exams, which are obtained with radiopharmacs injections, followed by radiography. In this study it was used 10 healthful male dogs of Rottweiler breed, radiographically normal and serum negative for dirofilariasis, with administration of varied doses of human serum albumin grouped marked with technetium-99m (MAA). The results were evaluated qualitatively and quantitatively, considering the index of pulmonary perfusion and its homogeneity, being found an increase on the homogeneity of image directly related with the number of MAA particles injected. This study defines the criteria of normality and the dosage of pulmonary perfusion in healthful dogs established with scintigraphy technique.
A avaliação da função pulmonar em cães pode ser obtida mediante exames cintilográficos, os quais incluem a injeção de radiofármacos, seguida de radiografias. Neste estudo, foram utilizados 10 cães machos hígidos da raça Rottweiler e radiograficamente normais e soronegativos para dirofilariose, com administração de doses variadas de macroagregado de albumina sérica humana marcados com tecnécio-99m ([99mTc](MAA)). Os resultados foram avaliados qualitativa e quantitativamente, considerando o índice de perfusão pulmonar e sua homogeneidade, sendo dessa maneira visualizado um aumento na homogeneidade da imagem diretamente relacionado ao número de partículas de MAA injetado. Este estudo define os critérios de normalidade e de dosagem na perfusão pulmonar em cães hígidos da raça Rottweiller estabelecidos com a técnica de cintilografia.
Resumo
PURPOSE: To evaluate the effect of sildenafil, administered prior to renal ischemia/reperfusion (I/R), by scintigraphy and histopathological evaluation in rats. METHODS: Twenty-four rats were divided randomly into two groups. They received 0.1 ml of 99mTechnetium-etilenodicisteine intravenous, and a baseline (initial) renal scintigraphy was performed. The rats underwent 60 minutes of ischemia by left renal artery clamping. The right kidney was not manipulated. The sildenafil group (n=12) received orally 1 mg/kg of sildenafil suspension 60 minutes before ischemia. Treatment with saline 0.9 percent in the control group (n=12). Half of the rats was assessed after 24 hours and half after seven days I/R, with new renal scintigraphy to study differential function. After euthanasia, kidneys were removed and subjected to histopathological examination. For statistical evaluation, Student t and Mann-Whitney tests were used. RESULTS: In the control group rats, the left kidneys had significant functional deficit, seven days after I/R, whose scintigraphic pattern was consistent with acute tubular necrosis, compared with the initial scintigraphy (p<0.05). Sildenafil treatment resulted in better differential function of the left kidneys 24h after reperfusion, compared with controls. Histopathologically, the left kidney of control rats (24 hours after I/R) showed a higher degree of cellular necrosis when compared with the sildenafil treated rats (p<0.05). CONCLUSION: Sildenafil had a protective effect in rat kidneys subjected to normothermic I/R, demonstrated by scintigraphy and histomorphometry.(AU)
OBJETIVO: Estudar o efeito do sildenafil, administrado previamente à isquemia/reperfusão (I/R) renal, em avaliações cintilográficas e histopatológicas em ratos. MÉTODOS: Vinte e quatro ratos Wistar foram aleatoriamente distribuídos em dois grupos. Os animais receberam 0,1 ml IV de 99mTecnécio-Etilenodicisteína, foram submetidos à cintilografia renal inicial e em seguida submetidos a isquemia no rim esquerdo, com oclusão da artéria renal, durante 60 minutos, com posterior reperfusão. O grupo sildenafil (n=12) recebeu previamente 1mg/kg de sildenafil em suspensão 60 minutos antes da isquemia. Solução salina 0,9 por cento foi administrada no grupo controle (n=12). Metade dos animais de cada grupo foi avaliada após 24 horas e a outra metade após sete dias de reperfusão, com nova cintilografia renal. Após eutanásia, os rins foram retirados e submetidos a exame histopatológico. Na avaliação estatística foram empregados os testes t de Student e de Mann-Whitney. RESULTADOS: Foi observado no rim esquerdo (submetido a I/R) do grupo controle déficit funcional diferencial nas imagens cintilográficas após sete dias, com padrão de necrose tubular aguda, quando comparado com a cintilografia inicial (p<0,05). O tratamento com sildenafil resultou em melhor função diferencial do rim esquerdo 24h após reperfusão, comparado com os controles. Na histopatologia, os rins esquerdos dos animais do grupo controle (24 horas pós-I/R), apresentaram maior grau de necrose celular quando comparados com o grupo tratado com o sildenafil (p<0,05). CONCLUSÃO: O sildenafil teve efeito protetor em rins de ratos submetidos à isquemia/reperfusão normotérmica, demonstrado por cintilografia e histomorfometria.(AU)
Assuntos
Animais , Ratos , Isquemia/terapia , Reperfusão/reabilitação , Rim , Preparações Farmacêuticas/administração & dosagem , Isquemia/fisiopatologia , Cintilografia , Tecnécio Tc 99m Mertiatida/análiseResumo
Na rotina clínica de felinos domésticos, algumas modalidades de diagnóstico por imagem, como a ultra-sonografia, radiografia simples e urografia excretora, já são amplamente utilizadas. A cintilografia é uma técnica não invasiva, capaz de oferecer informações funcionais de rins individualmente, porém é considerada uma modalidade menos usual. O objetivo deste estudo foi determinar o tempo de excreção renal de felinos domésticos através da cintilografia, em animais com parâmetros ultra-sonográficos e radiográficos dentro dos limites da normalidade. Foram utilizados 15 animais, 9 machos e 6 fêmeas, e estes foram divididos em grupos de animais não submetidos à anestesia e anestesiados. Foi estabelecido o tempo para o radiofármaco obter acúmulo máximo em cada um dos rins e o tempo para este acúmulo máximo ser reduzido pela metade. Não houve diferença estatística entre os valores dos animais não-anestesiados e anestesiados, nem entre machos e fêmeas, tampouco entre os rins esquerdo e direito
In internal medicine of domestic cats, imaging modalities, such as ultrasonography, radiography and intravenous pylogram are widely used. Scintigraphy is a non-invasive technique, which provides functional information of each individual kidney; however, it is not widely available or utilized currently in veterinary medicine. The aim of this study was to determine the time of excretion of each kidney in normal domestic cats using nuclear scintigraphy. Fifteen cats (9 males and 6 females) determined to be within normal limits for radiographic and ultrasonographic renal parameters, were divided into two experimental groups (awake and anesthetized cats). Time to maximum radiopharmaceutical activity (T max) and time to decline to half maximum radiopharmaceutical activity (half-time) were determined in each kidney for each cat. No statistical difference was found between groups (awake vs. anesthetized) or sex (males vs. females), or between left and right kidneys
Resumo
A identificação e biópsia do primeiro linfonodo a receber a linfa de uma formação neoplásica, ou seja, do linfonodo sentinela, fornecem informações essenciais para o tratamento e prognóstico de pacientes humanos acometidos por neoplasia. Entretanto, em Medicina Veterinária existem poucos estudos sobre a drenagem linfática dos órgãos e o conceito de linfonodo sentinela ainda não é amplamente aplicado ao tratamento oncológico dos animais. Desta forma, nosso objetivo no presente estudo foi estabelecer um protocolo de aquisição cintilográfica linfática, ou linfocintilográfica, capaz de fornecer informações funcionais e topológicas da drenagem linfática mamária, pois, em cadelas, as glândulas mamárias ainda são uns dos principais órgãos acometidos por neoplasias. Neste estudo, a linfocintilografia foi utilizada para caracterização topológica e funcional in vivo da drenagem linfática de glândulas mamárias sadias de 30 fêmeas da espécie canina (Canis familiares), sem raça definida e peso aproximado de 10 Kg. O radiofármaco [99mTc]-dextran70 foi administrado por via intraparenquimatosa mamária em quatro pontos ao redor da papila (0,1 ml cada), na dose de 18,5 MBq. As imagens foram obtidas em duas seqüências de projeções laterais e ventrais, sendo uma logo após a administração do [99m
The knowledge of lymphatic drainage has prognostic and surgical value for oncological treatment. Once you know the lymph nodes that drain the organ, you can predict the possible neoplasic cell route and avoid or predict metastasis. The lymphoscintigraphy is not common in Veterinary Nuclear Centers, however this technique has high applicability in oncological studies. During this study, the lymphoscintigraphie was used to characterize topological and functional aspects of lymphatic health mammary drainage in 30 adult mongrel female dogs, 10Kg in weigh. Lymphoscintigraphies were performed immediately after 4 intramammary peripapilare injections (0, 1 ml each) of 18,5 MBq of [99mTc]-dextran70 and one hour later. Animals were imaged by lateral and ventral projections. Cranial thoracic glands were drained by ventral thoracic and axillary lymph centers, but we observed the simultaneous participation of superficial cervical lymph center in 40% of these (2 animals). This result was similar for caudal thoracic mammary glands, but not for cervical lymph center drainage, that was not observed in caudal thoracic glands lymphoscintigraphies. Cranial abdominal glands were drained exclusively by the axillary lymph center. Superficial and deep inguinal lymph centers drained caudal abdominal and inguinal mammary glands, but we observed one superficial cervical lymph center participation in a caudal abdominal mammary gland drainage. Our lymphoscintigraphic technique provided image of lymphatic communication between axillary lymph nodes and between superficial and deep inguinal lymph nodes. The number of lymph centers and lymph nodes, the lymph center drainage rate and functional behavior of each lymph nodes were variable. In conclusion, the lymphoscintigraphic protocol performed was simple, quickly and provided the lymphatic drainage characterization. Technique, topologic and functional information provided by the present study can be applied to understand neoplasic mammary cells dissemination routes, which has prognostic and treatment value for patients. Veterinary centers that have no Nuclear Medicine facilities can use these topologic and functional information of the present study in other diagnostic procedures such as the abdominal ultra-sound and lymph node biopsy of patients with mammary neoplasia
Resumo
A avaliação da técnica de cintilografia da perfusão pulmonar foi realizada em 10 cães machos, da raça Rottweiler, radiograficamente normais e soronegativos para dirofilariose, utilizando-se o macroagregado de albumina sérica humana marcado com tecnécio-99m ([99mTc](MAA)) como radiofármaco. Cada animal sedado foi submetido a três diferentes tratamentos, com administração de 50.000, 100.000 e 300.000 partículas de MAA. As imagens obtidas com as doses variadas do radiofármaco, foram comparadas de forma qualitativa e quantitativa, incluindo nesta última a avaliação do índice de perfusão pulmonar e homogeneidade das imagens. Não foram observadas diferenças significativas entre as imagens durante a avaliação visual e cálculo da quantificação relativa da perfusão pulmonar. Porém, o cálculo da uniformidade integral demonstrou diferença significativa na homogeneidade da imagem pulmonar entre as diferentes doses de MAA. Pode-se concluir que existe um aumento na homogeneidade da imagem diretamente relacionado ao número de partículas de magroagregado de albumina injetado, ainda que tal diferença não tenha sido percebida pela análise qualitativa
The evaluation of pulmonary perfusion scintigraphy technique was accomplished in 10 Rottweiler male dogs, with normal thoracic radiographs and negative for Dirofilaria immitis, using macroaggregated human serum albumin tagged with technetium-99m ([99mTc](MAA)) as radiopharmaceutical. Each sedated animal was subimited to 3 different treatments, with administration of 50.000, 100.000 and 300.000 particles of MAA. The obtained images with diverse radiopharmaceutical doses were qualitative and quantitative compared, including in this the evaluation of radiopharmaceutical distribution and the homogeneity index. There were observed no significative differences between the images during the visual evaluation and calculation of the relative quantification of the lung perfusion. However, the integral uniformity calculation demonstrated significative difference at the homogeneity of the lung image between the different MAA doses. That leads to the conclusion that there is an increase at the images homogeneity directly related to the number of albumin macroaggregated particles injected, though difference has not been realized by the qualitative analysis
Resumo
A vascularização arterial do baço do eqüino foi estudada por meio de radiografias contrastadas, cintilografias, dissecações e moldes. O baço está situado no antímero esquerdo e a sua posição na cavidade abdominal determina uma face parietal lisa e levemente convexa, enquanto que a face intestinal, onde estão localizados os vasos, nervos e ligamentos, é levemente côncava determinando uma área com menor espessura. O estudo da vascularização arterial demonstrou uma área paucivascular que coincide justamente com a área côncava onde a espessura é menor. Este comportamento foi observado tanto nos adultos como nos fetos. Baseado na distribuição dos vasos arteriais a região onde a espessura é menor foi indicada como local de eleição para a incisão no caso de esplenectomias parciais, dividindo o baço do eqüino em dois segmentos anátomo-cirúrgicos. A cirurgia de ressecção parcial do baço não foi descrita, no cavalo, conforme atesta a literatura atual. Duas cirurgias experimentais foram realizadas para comprovar a indicação, demonstrando que a proposta é exeqüível. A análise proporcional da área mostrou que a ressecção parcial na região indicada preserva em média 50% do parênquima
Observation on the mode of parenchymal distribution of equine splenic artery was studied using arteriography, scintigraphy, dissection and corrosion cast. The spleen is situated in the left region of the abdomen. The parietal surface is convex and the visceral surface, where the blood vessels, nerves and ligaments are situated, is concave. The vascular arrangement may lead to division the organ into two anatomicosurgical segments. No literature is available on partial splenectomy in horses. Two partial resection was performed successfully by the method described, this partial resection preserve 50% of spleen parenchyma