Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Acta sci. vet. (Impr.) ; 47: Pub.1713-2019. ilus, tab
Artigo em Inglês | VETINDEX | ID: biblio-1458111

Resumo

Background: The Vertebral Heart Size (VHS) method sets standards for the evaluation of dog’s heart size from the comparison of the cardiac dimension with the length of the thoracic vertebrae through radiographic study. Electrocardiogram(ECG) is widely used in veterinary medicine for the evaluation of electrical conduction system of the heart; however, theincrease of duration and amplitude of the ECG waves can suggest the increase of cardiac chambers in dogs. The scientificliterature presents electrocardiographic and VHS values for dogs of different breeds and sizes; however, there is little information on the correlation of these parameters. Therefore, the aim of this study was to evaluate the amplitude and durationof ECG waves, thoracic morphometry and VHS values, in order to correlate these parameters in clinically normal dogs.Materials, Methods & Results: Twenty healthy dogs (11 females and 9 males), without breed distinction, medium sized(14.46 ± 2.92 kg) and aged between 1 and 8 years, were evaluated through physical examination, digital ECG (frontaland precordial leads) and thorax X-ray in right lateral (RL), left lateral (LL) and ventrodorsal (VD) projections. Thoracicmorphometry and VHS measurements were determined as previously described. Clinical and ECG parameters were compatible with the references in all dogs evaluated. Dogs presented thorax intermediate (75%) with the depth and width ratio(D/W ratio) > 1.0. Some individual VHS values were higher than the references and the mean VHS values in VD projectionwas higher than in RL and LL projections (n = 20; P < 0.05). Female and male dogs did not differ among the evaluatedparameters. A positive correlation was observed between thoracic morphometry and body weight (r ≥ +0.70; P < 0.001)and a negative correlation was found between the D/W ratio and VD VHS (r = -0.62; P < 0.05). No significant correlationswere observed between the age, ECG parameters, thoracic morphometry and...


Assuntos
Animais , Cães , Coração/anatomia & histologia , Coração/diagnóstico por imagem , Vértebras Torácicas/anatomia & histologia , Eletrocardiografia/veterinária , Tamanho do Órgão
2.
Acta sci. vet. (Online) ; 47: Pub. 1713, Dec. 12, 2019. ilus, tab
Artigo em Inglês | VETINDEX | ID: vti-25452

Resumo

Background: The Vertebral Heart Size (VHS) method sets standards for the evaluation of dogs heart size from the comparison of the cardiac dimension with the length of the thoracic vertebrae through radiographic study. Electrocardiogram(ECG) is widely used in veterinary medicine for the evaluation of electrical conduction system of the heart; however, theincrease of duration and amplitude of the ECG waves can suggest the increase of cardiac chambers in dogs. The scientificliterature presents electrocardiographic and VHS values for dogs of different breeds and sizes; however, there is little information on the correlation of these parameters. Therefore, the aim of this study was to evaluate the amplitude and durationof ECG waves, thoracic morphometry and VHS values, in order to correlate these parameters in clinically normal dogs.Materials, Methods & Results: Twenty healthy dogs (11 females and 9 males), without breed distinction, medium sized(14.46 ± 2.92 kg) and aged between 1 and 8 years, were evaluated through physical examination, digital ECG (frontaland precordial leads) and thorax X-ray in right lateral (RL), left lateral (LL) and ventrodorsal (VD) projections. Thoracicmorphometry and VHS measurements were determined as previously described. Clinical and ECG parameters were compatible with the references in all dogs evaluated. Dogs presented thorax intermediate (75%) with the depth and width ratio(D/W ratio) > 1.0. Some individual VHS values were higher than the references and the mean VHS values in VD projectionwas higher than in RL and LL projections (n = 20; P < 0.05). Female and male dogs did not differ among the evaluatedparameters. A positive correlation was observed between thoracic morphometry and body weight (r ≥ +0.70; P < 0.001)and a negative correlation was found between the D/W ratio and VD VHS (r = -0.62; P < 0.05). No significant correlationswere observed between the age, ECG parameters, thoracic morphometry and...(AU)


Assuntos
Animais , Cães , Coração/anatomia & histologia , Coração/diagnóstico por imagem , Vértebras Torácicas/anatomia & histologia , Eletrocardiografia/veterinária , Tamanho do Órgão
3.
Semina Ci. agr. ; 40(1): 191-202, Jan.-Feb. 2019. ilus, tab, graf
Artigo em Inglês | VETINDEX | ID: vti-19386

Resumo

The aim of this study was to estimate echocardiographic elevated mean left atrium pressure (MLAP) based on measurements from thoracic radiographs and to determine a cut-off value for each radiographic measurement that suggests a high MLAP. A retrospective cross-sectional study was performed to include cases admitted from January 2015 to December 2016. Thoracic radiographic examinations from 93 dogs with and without a high MLAP were included. Specific measurements were made from thoracic radiographs and compared with echocardiographic variables known to indicate high MLAP. This comparison was used to generate equations that allowed the estimation of echocardiographic surrogates from the radiographic measurements. The values indicative of high MLAP were obtained using a regression curve. Formulas that indicated high MLAP were generated using a number of radiographic measurements. Positive echocardiographic findings of high MLAP were used as the gold standard. These formulas helped to predict high MLAP in myxomatous mitral valve disease (MMVD) without the need for echocardiographic examination. The best formula was left atrium (LA):aorta (Ao)echo = 0.03×(vertebral heart score,VHS) + 0.14×(LA) + 0.27×(LA:caudal vena cava (CVC)rad). Values ≥ 12.2v for VHS, ≥ 4.5cm for LA, ≥ 3.3 for LA:Ao rad and ≥ 3.2 for LA:CVC rad suggested high MLAP. Thus, we propose equations, based on measurements from thoracic radiographs, to identify high MLAP. Simple radiographic thoracic measurements, such as LA:CVCrad, can be used to define overload and a high MLAP in dogs with MMVD.(AU)


O objetivo desse estudo foi estimar o aumento da pressão média do átrio esquerdo (PMAE) na ecocardiografia usando equações baseadas em medidas obtidas das radiografias torácicas e determinar um valor de corte para cada uma dessas variáveis radiográficas. Foi realizado um estudo retrospectivo, observacional e transversal de casos atendidos de janeiro de 2015 a dezembro de 2016. Foram selecionados 93 exames radiográficos do tórax de cães, com ou sem aumento da PMAE. As medidas especificas foram feitas de radiografias torácicas e comparadas com variáveis ecocardiográficas que podem indicar um aumento da PMAE. Foi gerado equações que estimam medidas ecocardiográficas a partir das variáveis radiográficas. Os valores que indicam aumento da PMAE foram obtidos por meio das curvas de regressão. Foram usadas como "padrão ouro" as medidas ecocardiográficas que indicam aumento da PMAE. As fórmulas ajudam a predizer o aumento da PMAE em cães com doença mixomatosa da valva mitral (DMVM) sem a necessidade do exame ecocardiográfico. A melhor fórmula obtida foi: Átrio Esquerdo (AE):Aorta (Ao)eco=0.03×(VHS)+0.14×(AE)+0.27×(AE:Veia Cava Caudal (VCC)rad). Os valores ≥ 12.2 para VHS, ≥ 4.5cm para AE; ≥ 3.3 para AE:Ao rad e ≥ 3.2 para AE:VCC rad sugerem um aumento da PMAE. Essas equações, a partir de medidas radiográficas torácicas, auxilia na identificação do aumento da PMAE. Algumas medidas radiográficas simples, como a AE:VCC rad pode ser usada para definir sobrecarga e aumento da PMAE em cães com DMVM.(AU)


Assuntos
Animais , Cães , Valva Mitral/fisiopatologia , Pressão Atrial , Átrios do Coração/fisiopatologia , Técnicas de Diagnóstico Cardiovascular/veterinária , Veias Pulmonares/fisiopatologia , Radiografia Torácica/veterinária , Ecocardiografia/veterinária
4.
Acta sci. vet. (Online) ; 44: 01-07, 2016. ilus, tab, graf
Artigo em Inglês | VETINDEX | ID: vti-722698

Resumo

Background: Veterinary cardiology has been widely divulged, especially because of the search for diagnostic methods that allow early identification of heart disease in companion animals. Several techniques are available, such as digital radiography (DR), computerized tomography (CT) and magnetic resonance (MR) that are being applied to patients with various diseases. VHS has been widely used in clinical practice in veterinary medicine as a way to diagnose heart size increases in lateral thoracic radiography in small animals. Cardiothoracic ratio (CTR) is a predictive factor for cardiac insufficiency in humans. In veterinary medicine, this index is still little used. The objective of the present study was to compare the vertebral heart scale (VHS) and cardiothoracic ratio (CTR) to assess changes in the size of the cardiac silhouette dogs in thoracic radiographs. Materials, Methods & Results: The VHS and CTR of forty healthy poodle breed dogs (20 males and 20 females) from University Veterinary Hospital at the Federal University of Piauí were assessed. The animals were placed in supine and lateral decubitus, to obtain radiographic images in dorsoventral (DV) and right and left laterolateral projections of the thoracic region. The images acquired on the photosensitive radiographic chassis were analyzed by digital radiographic image system installed in the Image Diagnosis [...](AU)


Assuntos
Animais , Cães , Coração/anatomia & histologia , Cardiopatias/diagnóstico , Cardiopatias/veterinária , Padrões de Referência/análise , Técnicas de Diagnóstico Cardiovascular/veterinária , Pesos e Medidas Corporais/veterinária , Cardiomegalia/veterinária , Ecocardiografia/veterinária
5.
Acta sci. vet. (Impr.) ; 44: 01-07, 2016. ilus, tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1457429

Resumo

Background: Veterinary cardiology has been widely divulged, especially because of the search for diagnostic methods that allow early identification of heart disease in companion animals. Several techniques are available, such as digital radiography (DR), computerized tomography (CT) and magnetic resonance (MR) that are being applied to patients with various diseases. VHS has been widely used in clinical practice in veterinary medicine as a way to diagnose heart size increases in lateral thoracic radiography in small animals. Cardiothoracic ratio (CTR) is a predictive factor for cardiac insufficiency in humans. In veterinary medicine, this index is still little used. The objective of the present study was to compare the vertebral heart scale (VHS) and cardiothoracic ratio (CTR) to assess changes in the size of the cardiac silhouette dogs in thoracic radiographs. Materials, Methods & Results: The VHS and CTR of forty healthy poodle breed dogs (20 males and 20 females) from University Veterinary Hospital at the Federal University of Piauí were assessed. The animals were placed in supine and lateral decubitus, to obtain radiographic images in dorsoventral (DV) and right and left laterolateral projections of the thoracic region. The images acquired on the photosensitive radiographic chassis were analyzed by digital radiographic image system installed in the Image Diagnosis [...]


Assuntos
Animais , Cães , Cardiopatias/diagnóstico , Cardiopatias/veterinária , Coração/anatomia & histologia , Cardiomegalia/veterinária , Ecocardiografia/veterinária , Padrões de Referência/análise , Pesos e Medidas Corporais/veterinária , Técnicas de Diagnóstico Cardiovascular/veterinária
6.
Pesqui. vet. bras ; 35(10): 853-858, Oct. 2015. tab, graf
Artigo em Inglês | VETINDEX | ID: vti-702

Resumo

The VHS and CTR were assessed using computerized thoracic radiographs of ten clinically healthy tufted capuchin monkeys (five males and five females) from the Wild Animal Screening Center in São Luís (Centro de Triagem de Animais Silvestres de São Luís-MA-CETAS). Radiographs were taken in laterolateral and dorsoventral projections to calculate the cardiothoracic ratio (VHS) and vertebral heart size (CTR). The VHS showed mean values of 9.34±0.32v (males) and 9.16±0.34v (females) and there was no statistical difference between males and females (p>0.05). The CTR showed mean values of 0.55±0.04 (males) and 0.52±0.03 (females) and there was no statistical difference between the sexes (p>0.05). There was positive correlation between VHS and CTR (r=0.78). The thoracic and heart diameters showed mean values of 5.70±0.48cm and 2.16±0.40cm in the males, respectively. In the females they measured 5.32±0.39cm and 2.94±0.32cm. There was no statistical difference between the sexes. Our results show that the high correlation found between VHS and CTR permitted the verification with similar clinical precision between the two methods to estimate alterations in the heart silhouette by radiographic examination of tufted capuchin, making it an easy technique to apply that can be considered in the investigation of heart problems for this wild species.(AU)


Para a avaliação do VHS e ICT foram utilizadas radiografias torácicas computadorizadas de 10 macacos-prego (05 machos e 05 fêmeas) clinicamente saudáveis, oriundos do Centro de Triagem de Animais Silvestres de São Luís-MA-CETAS. Foram tomadas radiografias em projeções laterolaterais e dorsoventrais, para cálculo do Vertebral Heart Scale (VHS) e Índice Cardiotorácico (ICT). O VHS evidenciou valores médios de 9,34±0,32v (machos) e 9,16±0,34v (fêmeas), não ocorrendo diferença estatística entre machos e fêmeas (p>0,05). O ICT evidenciou valores médios de 0,55±0,04 (machos) e de 0,52±0,03 (fêmeas), não sendo verificada diferença estatística entre sexos (p>0,05). Verificou-se correlação positiva entre VHS e ICT (r=0,78). Os diâmetros torácico e cardíaco demonstraram valores médios de 5,70±0,48cm e 3,16±0,40cm nos machos, respectivamente. Nas fêmeas mediram 5,32±0,39cm e 2,94±0,32cm. Não houve diferença estatística entre os sexos (p>0,05). Os nossos resultados demonstraram que a alta correlação encontrada entre o VHS e o ICT permitiu verificar precisão clínica semelhante entre os dois métodos, para estimar alterações da silhueta cardíaca ao exame radiográfico de macacos-prego, constituindo-se como uma técnica de fácil aplicação, poddevendo ser considerada na investigação de problemas cardíacos para esta espécie silvestre.(AU)


Assuntos
Animais , Radiografia Torácica/veterinária , Vértebras Torácicas , Cebus/anatomia & histologia , Coração/anatomia & histologia , Coração , Técnicas de Diagnóstico Cardiovascular/veterinária , Animais Selvagens/anatomia & histologia
7.
Tese em Português | VETTESES | ID: vtt-220762

Resumo

O cachorro-do-mato (Cerdocyon thous) é uma das seis espécies de canídeos silvestres, presente em todos os biomas brasileiros, com exceção da Amazônia, e em alguns países sul-americanos. Esta disseminação territorial, deve-se a sua adaptação alimentar e reprodutiva em consequência da expansão das atividades humanas. Contudo, uma dieta desbalanceada, bem como a consanguinidade entre a espécie, pode permitir o aparecimento de anomalias congênitas, e entre elas, as alterações cardíacas. Sabendo-se que o Cerdocyon thous (C. thous) encontra-se em constante contato com a atividade humana, estando susceptível a possíveis traumas, e notada a escassa publicação literária ao que se diz respeito da avaliação cardíaca na referida espécie, visou-se a realização da mesma pela análise da pressão arterial sistólica, radiografia torácica (VHS), ecocardiografia e dosagem dos níveis séricos de troponina (cTnI) de 12 distintos C. thous de cativeiro, aos quais foram anestesiados com cetamina e midazolam. Foi realizada a estatística descritiva dos dados coletados e correlação dentre os índices que apresentaram alguma verossimilhança dentre distintos exames complementares supracitados, nos quais observou-se diminuição de algumas medidas ventriculares lineares e indexadas, diminuição do tempo do tempo de desaceleração da onda E, bem como de maior credibilidade ao se comparar as dimensões lineares dentre diferentes canídeos silvestres por meio da escala alométrica.


Cerdocyon thous is one of six species of Brazilian wild canids, present in all Brazilian biomes, except the Amazon, and in some South American countries. This territorial dissemination is due to its food and reproductive adaptation as a result of the expansion of human activities. However, an unbalanced diet, as well as inbreeding between the species, can allow the appearance of congenital anomalies, and among them, such as cardiac changes. Knowing that Cerdocyon thous (C. thous) is in constant contact with human activity, susceptible to possible traumas, and the scarce literary publication regarding cardiac evaluation in the species was noted, the aim was to achieve of the same through the systolic blood pressure, chest radiography (VHS), echocardiography and measurement of the serum levels of troponin (cTnI) of 12 different C. thous of captivity, to which they were anesthetized with ketamine and midazolam. A descriptive statistics of the collected data was carried out and among the indices that some likelihood source among the different complementary tests mentioned above, in which there was less decrease in some linear and indexed ventricular measures, decrease in the TDE time, as well as greater credibility when comparing the linear dimensions among different canine wilds using the allometric scale.

8.
Semina ciênc. agrar ; 35(supl.4): 2501-2506, 2014. ilus, graf
Artigo em Inglês | VETINDEX | ID: biblio-1499811

Resumo

A determinação do tamanho do coração é importante na avaliação de pacientes cardiopatas, pois o aumento da silhueta cardíaca, na radiografia torácica, pode ser indicativa de enfermidade cardíaca. O sistema VHS (vertebral heart size) é util porque permite avaliar, objetivamente, os limites da silhueta cardíaca, auxiliando na avaliação de cardiomegalia e documentando alterações do tamanho cardíaco em resposta ao tratamento ou à progressão da doença. O objetivo deste trabalho foi comparar valores de VHS de gatos Maine Coon (GMC) sadios com aqueles citados na literatura (7,5±0,3 vértebras) obtidos de gatos não Maine Coon (GNMC). Sessenta e três GMC foram avaliados por meio de exames físico, eletrocardiográfico, ecocardiográfico, laboratoriais (hemograma, funções hepática e renal, T4 total), bem como pela determinação da pressão arterial. Frente a resultados normais, os animais foram posicionados em decúbito lateral direito (projeção látero-lateral direita), para realização da radiografia torácica, realizada utilizando o sistema Fuji de radiografia computadorizada. Os valores de VHS obtidos neste trabalho foram 7,61±0,34 vértebras, com mínimo de 6,9 e máximo de 8,5 vértebras. A análise estatística realizada pelo teste t de Student mostrou diferença significativa entre os valores ora obtidos em relação àqueles citados na literatura (p=0.03) para gatos não Maine Coon. Os valores de VHS maiores observados em GMC podem estar associados com o porte gigante desta raça de gatos.


Determining the size of the heart is important for evaluating cardiac patients, because the increase of the cardiac silhouette in the chest radiography can be indicative of heart disease. The vertebral heart size (VHS) method is useful because it allows objective assessment of the limits of cardiac silhouette, and can help assess cardiomegaly and document changes in heart size in response to treatment or disease progression. The aim of this study was to compare VHS values of Maine Coon cats (MCC) with values cited in the literature (7.5 ± 0.3 vertebrae) obtained in non Maine Coon cats (NMCC). Sixty three MCC underwent the physical examination, electrocardiography, echocardiography, laboratory tests (blood count, biochemistry, including liver and kidney function, and total T4), as well as measurement of blood pressure. Faced with normal results, the cats were positioned in right lateral decubitus (right laterallateral projection), to perform chest radiography. The radiographic examinations were performed using the Fuji computed radiography system. The values of VHS found in the animals of this study were 7.61 ± 0.34 vertebrae with a minimum of 6.9 and of maximum 8.5 vertebrae. Statistical analysis performed by Students t test identified a significant difference between the values obtained in this study with those in the literature (p = 0.03) for non Maine Coon cats. The highest values of VHS obtained in MCC may be associated with the size of this giant breed.


Assuntos
Animais , Gatos , Cardiomegalia/prevenção & controle , Cardiomegalia/veterinária , Coração/anatomia & histologia , Coração/diagnóstico por imagem , Ecocardiografia/veterinária , Eletrocardiografia/veterinária
9.
Semina Ci. agr. ; 35(supl.4): 2501-2506, 2014. ilus, graf
Artigo em Inglês | VETINDEX | ID: vti-26494

Resumo

A determinação do tamanho do coração é importante na avaliação de pacientes cardiopatas, pois o aumento da silhueta cardíaca, na radiografia torácica, pode ser indicativa de enfermidade cardíaca. O sistema VHS (vertebral heart size) é util porque permite avaliar, objetivamente, os limites da silhueta cardíaca, auxiliando na avaliação de cardiomegalia e documentando alterações do tamanho cardíaco em resposta ao tratamento ou à progressão da doença. O objetivo deste trabalho foi comparar valores de VHS de gatos Maine Coon (GMC) sadios com aqueles citados na literatura (7,5±0,3 vértebras) obtidos de gatos não Maine Coon (GNMC). Sessenta e três GMC foram avaliados por meio de exames físico, eletrocardiográfico, ecocardiográfico, laboratoriais (hemograma, funções hepática e renal, T4 total), bem como pela determinação da pressão arterial. Frente a resultados normais, os animais foram posicionados em decúbito lateral direito (projeção látero-lateral direita), para realização da radiografia torácica, realizada utilizando o sistema Fuji de radiografia computadorizada. Os valores de VHS obtidos neste trabalho foram 7,61±0,34 vértebras, com mínimo de 6,9 e máximo de 8,5 vértebras. A análise estatística realizada pelo teste t de Student mostrou diferença significativa entre os valores ora obtidos em relação àqueles citados na literatura (p=0.03) para gatos não Maine Coon. Os valores de VHS maiores observados em GMC podem estar associados com o porte gigante desta raça de gatos.(AU)


Determining the size of the heart is important for evaluating cardiac patients, because the increase of the cardiac silhouette in the chest radiography can be indicative of heart disease. The vertebral heart size (VHS) method is useful because it allows objective assessment of the limits of cardiac silhouette, and can help assess cardiomegaly and document changes in heart size in response to treatment or disease progression. The aim of this study was to compare VHS values of Maine Coon cats (MCC) with values cited in the literature (7.5 ± 0.3 vertebrae) obtained in non Maine Coon cats (NMCC). Sixty three MCC underwent the physical examination, electrocardiography, echocardiography, laboratory tests (blood count, biochemistry, including liver and kidney function, and total T4), as well as measurement of blood pressure. Faced with normal results, the cats were positioned in right lateral decubitus (right laterallateral projection), to perform chest radiography. The radiographic examinations were performed using the Fuji computed radiography system. The values of VHS found in the animals of this study were 7.61 ± 0.34 vertebrae with a minimum of 6.9 and of maximum 8.5 vertebrae. Statistical analysis performed by Students t test identified a significant difference between the values obtained in this study with those in the literature (p = 0.03) for non Maine Coon cats. The highest values of VHS obtained in MCC may be associated with the size of this giant breed.(AU)


Assuntos
Animais , Gatos , Coração/anatomia & histologia , Coração/diagnóstico por imagem , Cardiomegalia/prevenção & controle , Cardiomegalia/veterinária , Ecocardiografia/veterinária , Eletrocardiografia/veterinária
10.
Braz. j. vet. pathol ; 7(1): 03-06, Mar. 2014. tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1469879

Resumo

In order to detecting VHS virus titer in various tissues in clinical stage of VHS disease, rainbow trout,Oncorhynchus mykiss, were exposed to virus by bath. The experiments were carried out with 140 fish obtained fromrainbow trout farm. The fish were divided into two equal groups in 120 Liter tanks containing 70 fish. Group one wasconsidered as control and group two infected by bath challenge with 103 TCID50 ml-1 of a VHS virus strain serologicallysimilar to reference strain F1 with high pathogenicity in rainbow trout. At days 12, 13 and 14 post infection the organsincluding kidney, spleen, heart, skin, liver, pyloric caeca and brain were sampled from dead fish with appropriate clinicalsigns of VHS separately. Each sample was placed in vials adding 1 ml transport medium to assess virus titer in varioustissues. Results of the study, showed that significant difference between virus loads in various organs (p≤ 0.05). Thehighest virus titer belongs to the heart while it is in minimum amount in the skin. According to the virus quantity theexperimental tissues can be divided in three categories, respectively. Heart and kidney performed the highest amount ofvirus quantities while liver, gill, pyloric caeca and skin showed the lowest with brain and spleen lying in between. Theseresults point out that the significant levels of VHS virus found in rainbow trout tissues are relevant for the biosecurity inVHS-free areas mainly when fish are displayed and retained as whole fish.


Assuntos
Animais , Oncorhynchus mykiss/virologia , Septicemia Hemorrágica Viral/diagnóstico , Tropismo Viral
11.
Braz. J. Vet. Pathol. ; 7(1): 03-06, Mar. 2014. tab, graf
Artigo em Inglês | VETINDEX | ID: vti-22966

Resumo

In order to detecting VHS virus titer in various tissues in clinical stage of VHS disease, rainbow trout,Oncorhynchus mykiss, were exposed to virus by bath. The experiments were carried out with 140 fish obtained fromrainbow trout farm. The fish were divided into two equal groups in 120 Liter tanks containing 70 fish. Group one wasconsidered as control and group two infected by bath challenge with 103 TCID50 ml-1 of a VHS virus strain serologicallysimilar to reference strain F1 with high pathogenicity in rainbow trout. At days 12, 13 and 14 post infection the organsincluding kidney, spleen, heart, skin, liver, pyloric caeca and brain were sampled from dead fish with appropriate clinicalsigns of VHS separately. Each sample was placed in vials adding 1 ml transport medium to assess virus titer in varioustissues. Results of the study, showed that significant difference between virus loads in various organs (p≤ 0.05). Thehighest virus titer belongs to the heart while it is in minimum amount in the skin. According to the virus quantity theexperimental tissues can be divided in three categories, respectively. Heart and kidney performed the highest amount ofvirus quantities while liver, gill, pyloric caeca and skin showed the lowest with brain and spleen lying in between. Theseresults point out that the significant levels of VHS virus found in rainbow trout tissues are relevant for the biosecurity inVHS-free areas mainly when fish are displayed and retained as whole fish.(AU)


Assuntos
Animais , Oncorhynchus mykiss/virologia , Septicemia Hemorrágica Viral/diagnóstico , Tropismo Viral
12.
Tese em Português | VETTESES | ID: vtt-216684

Resumo

Com o objetivo de avaliar os dados da resenha, alterações laboratoriais e radiográficas de cães geriátricos foram estudadas fichas clínicas de 156 cães com idade igual ou superior a sete anos. Foram anotados os dados referentes resenha, motivo das consultas, achados radiográficos torácicos, VHS, hemogramas e bioquímicas sanguíneas. O número de fêmeas (n=114) foi superior ao de machos (n=42). As raças mais prevalentes foram animais SRD (27%), Poodle (14%) e Pitbull (10%). A suspeita de metástase pulmonar (62%) foi o maior motivo de consulta. Valores de hemácias, hematócrito e hemoglobina estavam nos limites inferiores, sugerindo anemia em 35,25%. Leucopenia foi observada em 12,17% de animais e leucocitose em 21,8%. Em 10,26% dos cães foi notada trombocitopenia e em 25,64% trombocitose. Os valores médios da FA, ALT e ureia foram superiores aos de referência. As medidas do VHS foram similares aos valores propostos pela literatura nas diferentes raças estudadas. O maior cuidado básico dos cães, meios de diagnósticos avançados e especialidades na veterinária, tem contribuído para o aumento da expectativa de vida dos cães. As fêmeas compõem estão em maior dentre a população de cães geriátricos. Os cães SRD têm expectativa de vida maior, seguido pelos de pequeno porte. Os cães geriátricos são levados para consulta devido à suspeita de metástase pulmonar, avaliação cardiorrespiratória, check-up e avaliação torácica geral. Cães geriátricos têm propensão a maior peso coporal, anemia e leucocitose. A um paciente geriatra recomenda-se avaliação hematológica e bioquímica e exames de imagem como radiografia torácica.


In order to evaluate the data from the review, laboratory and radiographic changes of geriatric dogs, clinical files of 156 dogs aged seven years or more were studied. The data referring to the review, reason for the consultations, thoracic radiographic findings, HSV, hemograms and blood biochemistry were recorded. The number of females (n = 114) was higher than that of males (n = 42). The most prevalent breeds were SRD (27%), Poodle (14%) and Pitbull (10%). The suspicion of pulmonary metastasis (62%) was the major reason for consultation. Red blood cells, hematocrit and hemoglobin values were lower, suggesting anemia in 35.25%. Leukopenia was observed in 12.17% of animals and leukocytosis in 21.8%. In 10.26% of the dogs thrombocytopenia was noted and in 25.64% thrombocytosis. The mean values of AF, ALT and urea were higher than the reference values. The measurements of HSV were similar to the values proposed by the literature in the different breeds studied. The greater basic care of dogs, means of advanced diagnoses and veterinary specialties, has contributed to the increase of life expectancy of the dogs. Females make up are in the highest geriatric population. SRD dogs have longer life expectancy, followed by small ones. Geriatric dogs are brought to the clinic for suspicion of pulmonary metastasis, cardiorespiratory evaluation, check-up and general thoracic evaluation. Geriatric dogs are prone to increased body weight, anemia, and leukocytosis. A geriatric patient is recommended hematological and biochemical evaluation and imaging tests such as chest radiography.

13.
Pesqui. vet. bras ; 33(3): 411-416, mar. 2013. ilus, tab
Artigo em Inglês | VETINDEX | ID: vti-8579

Resumo

The agouti is a species intensively hunted throughout the Amazon and the semi-arid regions of northeastern Brazil. Considering the current trend in conservation management of wild species, the aim of this study was to determine the morphometric reference to the heart of agouti raised in captivity, based on thoracic and cardiac measurements in these animals. Thirty adult agoutis, 1 to 3 years of age, without clinical signs of cardiac disease were selected. The animals were physically restrained and radiographies in laterolateral (LL) and ventrodorsal (VD) recumbence were produced. The following measures were taken: the apicobasilar length of the heart (at the most cranial height of the Carina region to the heart apex) (AB), maximum width of the heart perpendicular to AB (CD), heart inclination angle (AIC), trachea inclination angle (AIT), distance from the right heart wall (DPTd), distance from the left heart wall (DPTe) and vertical depth of the thorax, and the ventral face of the vertebral column to the dorsal border of the sternum at the level of the trachea bifurcation (H). The ratios between AB/CD, AB/H and CD/H were also analyzed. To calculate the vertebral heart scale (VHS), the AB and CD measurements were laid over the thoracic vertebra starting at T4. Radiographic evaluation showed values consistent with those reported in small animals and some wild and exotic species. The main biometric values in the chest cavity and heart of agouti are arranged as follows: (1) The ratios between AB/H ratio and CD/H were not sensitive for identifying heart increases (p>0.05), while the ratio AB/CD was more sensitive in this identification (p<0.05); (2) AIC: 21.2±6.4º (mean between male and famale); (3) AIT for males and females: 9.93±3.23° and 8.4±3.94°; (4) DPTd and DPTe for males: 0.97±0.40cm and 0.7±0.30cm; (5) DPTd and DPTe for females: 1.12±0.42cm and 01.02±0.43cm; (6) VHS for males and females: 7.75±0.48v e 7.61±0.34v; (7) The caudal vena cava (CVC) was visualized dorsal-cranially and located right of the midline. The data obtained allowed the acquisition of the first reference values for biometry of the heart of agoutis, contributing to better understanding of cardiac morphology and identification of cardiomyopathy in these animals.(AU)


A cutia é uma espécie intensamente caçada em toda a Amazônia e nas regiões semi-áridas do Nordeste do Brasil. Considerando a tendência atual em gestão de conservação das espécies selvagens, o objetivo deste estudo foi determinar referências morfométricas para o coração de cutia criadas em cativeiro, com base em medições torácicas e cardíacas desses animais. Foram selecionados 30 cutias adultas, sem sinais clínicos de doença cardíaca, com idade entre 1 a 3 anos. Os animais foram contidos fisicamente e realizadas projeções radiográficas laterolaterais e (LL) e ventrodorsais (VD). As seguintes medidas foram tomadas: O comprimento apicobasilar do coração (na altura mais cranial da região carina até o ápice do coração) (AB); a largura máxima coração perpendicular a AB (CD); o ângulo de inclinação do cardíaca (AIC); ângulo de inclinação da traquéia (AIT); a distância a partir da parede direita do coração (DPTd); a distância a partir da parede esquerda do coração (DPTe) e profundidade vertical do tórax, da face ventral da coluna vertebral até à borda dorsal do esterno, no nível da bifurcação da traqueia (H). As relações entre AB/CD, AB/H e CD/H também foram analisadas. Para calcular o "vertebral heart scale" (VHS), as medidas AB e CD foram colocadas sob as vértebras torácicas a partir de T4. A avaliação radiográfica demonstrou valores consistentes com aqueles relatados em pequenos animais e algumas espécies selvagens e exóticos. Os principais valores biométricos mensurados na cavidade torácica e cardíaca da cutia, estão dispostas da seguinte forma: (1) As relações entre AB/H e CD/H não foram sensíveis para identificar aumento do coração (p> 0,05), enquanto a proporção AB/CD foi mais sensível nesta identificação (p <0,05); (2) AIC: 21,2 ± 6.4º (média entre machos e fêmeas); (3) AIT para machos e fêmeas: 9.93 ± 3.23° and 8.4±3.94°; (4) DPTd e DPTe para os machos: 0,97 ± 0,40 cm e 0,7 ± 0,30, (5) DPTd e DPTe para as fêmeas: 1,12 ± 0,42 e 01,02 ± 0,43; (6) VHS para machos e fêmeas: 7.75±0.48v e 7.61±0.34v; (7) A veia cava caudal (CVC) foi visualizada dorso-cranialmente e localizada à direita da linha média. Os dados obtidos permitiram a obtenção dos primeiros valores de referência para a biometria do coração de cutias, contribuindo para uma maior compreensão da morfologia cardíaca e identificação de cardiomiopatia nestes animais.(AU)


Assuntos
Animais , Roedores/anatomia & histologia , Radiografia Torácica/veterinária , Radiografia Torácica/métodos , Coração , Biometria , Padrões de Referência
14.
Tese em Português | VETTESES | ID: vtt-206726

Resumo

O diagnóstico por imagem em Medicina Veterinária tem tido avanços significativos nos últimos anos e a cardiologia vem se destacando por ter possibilidades de realização de exames não invasivos. Este trabalho teve por objetivo a padronização dos valores de VHS (Vertebral Heart Scale) e ICT (Índice Cardiotorácico) em catetos (Tayassu tajacu, Linnaeus, 1758) mensurados em radiografias torácicas digitais contidos com Cetamina e Midazolam; e a descrição do traçado eletrocardiográfico computadorizado em cutias (Dasyprocta prymnolopha, Wagler, 1831) contidas pela associação de Cetamina e Xilazina. Para tanto, foram utilizados 14 catetos hígidos, ambos os sexos, submetidos a exames radiográficos do tórax para obtenção de imagens em projeções dorsoventrais (DV) e láterolaterais direita e esquerda, por meio do aparelho de raios-x AGFA-Health Care CR30-X digital. Em relação as cutias, foram utilizados 18 animais clinicamente saudáveis, machos e fêmeas. Estes foram submetidos ao exame eletrocardiográfico com o auxílio de um eletrocardiógrafo digital, aparelho veterinário - TEB®, conectado a um notebook. A contenção química foi realizada em catetos atráves da associação de 15mg/kg de cetamina e 3mg/kg de maleato de midazolam e em cutias por meio da associação de 40mg/kg de cetamina e 1mg/kg de cloridrato de xilazina, por via intramuscular em ambas espécies. Os resultados evidenciaram que em catetos O VHS para decúbito direito nos machos demonstrou valor médio de 9,22±0,29v, enquanto que para o esquerdo foi de 8,87±0,42v, não sendo verificada diferença estatística entre os decúbitos (p>0,05). Para as fêmeas, o VHS no decúbito direito demonstrou valor médio de 8,55±0,47v e 8,81±0,42v para o decúbito esquerdo, não havendo diferença estatística entre os decúbitos (p>0,05). O Índice Cardiotorácico (ICT) apresentou valores médios de 0,50±0,05 para os machos e de 0,45±0,04 para as fêmeas, não havendo diferença estatística entre sexos (p>0,05). Para as cutias, os resultados obtidos demonstraram que a frequência cardíaca para machos ficou em média de 113,25 bpm, enquanto que para as fêmeas foi observado o valor de 124,60bpm, havendo diferença estatisticamente entre machos e fêmeas (p>0,05). O peso, apesar de ser maior para os machos (2,31 Kg), xiv comparado às fêmeas (2,28 Kg) não foi estatisticamente significativo. O QRS apresentou duração de 46,14ms (machos) e 44,66ms (fêmeas e o intervalo PR de 79,94ms (machos) e 84,29ms (fêmeas). A altura da onda R apresentou para machos o valor de 0,42mV e a onda T 0,24mV. Para fêmeas esses valores foram de 0,36mV a onda R e 0,25 mV a onda T. O estabelecimento dos valores de referência para mensurações cardíacas em catetos permitiu a padronização do VHS e ICT para esta espécie silvestre. O protocolo de contenção química utilizado neste experimento foi bem tolerado pelos animais e os efeitos dos fármacos não produziu depressão cardiovascular significante, não sendo observado cmplicações durante o experimento. Esses dados poderão servir como base para futuros estudos, bem como na aplicação na rotina clínica cardiológica de animais silvestres, auxiliando principalmente na realização de procedimentos que necessitem de contenção química destes animais.


Wild species have been increasingly exploited as a way to obtain information that favors their conservation, especially those threatened with extinction. The aim of this study was to standardize VHS (Vertebral Heart Scale) and Cardiothoracic Ratio (CTR) values of collared peccaries (Tayassu tajacu, Linnaeus, 1758) contained with Ketamine and Midazolam. Were evaluated 14 clinically healthy collared peccaries, with ages ranging about 2 years and mean weight variation of 15 to 22 kg. The animals were submitted to digital chest radiography in latero-lateral and dorsoventral projections for the calculation of Vertebral Heart Scale (VHS) and Cardiothoracic Ratio (CTR). The VHS showed mean values between 8.88±0.51v for right decubitus and 8.84±0.39v for left decubitus, with no statistical difference between decubitus (p> 0.05). The CTR showed mean values of 0.50 ± 0.05 (males) and 0.45±0,04 (females), with no significant statistical difference between the sexes (p> 0.05). There was a positive correlation between VHS and CTR (r = 0.98, right decubitus, r = 0.96, left decubitus). The establishment of reference values for cardiac measurements in collared peccary from digital chest radiographs allowed the standardization of VHS and CTR for this wild species. In the wild animal model studied, VHS and CTR cardiac indexes were shown as an essential diagnostic tool for investigations of changes in the size of the cardiac silhouette.

15.
Arq. bras. med. vet. zootec ; 63(4): 850-857, 2011. ilus, graf
Artigo em Português | VETINDEX | ID: vti-1032

Resumo

Determinou-se valor médio do vertebral heart size (VHS) em cães da raça Yorkshire Terrier. Foram selecionados 30 cães clinicamente normais, com média de peso de 2,42±0,64kg e idades entre um e seis anos. Os animais foram submetidos ao exame radiográfico do tórax nas projeções lateral direita, ventrodorsal e dorsoventral. Foram feitas mensurações para avaliação cardíaca e da profundidade e largura torácicas. O valor médio de VHS foi de 9,9±0,6 vértebras na projeção lateral, 10,1±0,6 vértebras na projeção ventrodorsal e 10,0±0,6 vértebras na projeção dorsoventral. Não houve diferença entre esses valores. Cinco animais (16,7 por cento) apresentaram VHS acima de 10,5 vértebras, valor sugerido como limite superior para a maioria das raças, em projeção lateral. Os valores de VHS correlacionaram-se com peso corporal nas projeções lateral e ventrodorsal. A razão profundidade:largura torácica apresentou valor médio de 0,75±0,06. Não foi observada correlação entre a qualidade do tórax e o VHS.(AU)


The mean vertebral heart size (VHS) was established for Yorkshire Terrier dogs. Thirty clinically normal dogs with mean weight of 2.42±0.64kg and ages varying from one to six years of age, were studied. The animals were submitted to right lateral, ventrodorsal and dorsoventral thoracic radiographs. The Buchanan e Bücheler method was applied to the cardiac silhouette and thoracic depth and width. The VHS was 9.9±0.6 vertebrae on lateral, 10.1±0.6 on ventrodorsal and 10.0±0.6 on dorsoventral radiographs. There was no difference among these values. Five animals (16.7 percent) presented VHS values exceeding 10.5, the value suggested as upper limit for most breeds in lateral view. However, 95 percent of the animals in this study provide VHS values below the upper limit, and this should be equal to 11 vertebrae. The VHS values had significant correlation with body weight on lateral and VD radiographs. The mean depth:width ratio was 0.75±0.06. There was no correlation among VHS and depth:width ratios.(AU)


Assuntos
Animais , Masculino , Feminino , Cães , Coração/anatomia & histologia , Coração , Radiografia Torácica/veterinária , Vértebras Torácicas , Radiografia/métodos , Tórax/anatomia & histologia
16.
Tese em Português | VETTESES | ID: vtt-202022

Resumo

Veterbral heart scale (VHS) e índice cardiotorácico (ICT): existe relação com a fração e ejeção e de encurtamento em cães poodle com função cardíaca preservada?


Veterbral heart scale (VHS) e índice cardiotorácico (ICT): existe relação com a fração e ejeção e de encurtamento em cães poodle com função cardíaca preservada?

17.
Artigo em Português | LILACS-Express | VETINDEX | ID: biblio-1502224

Resumo

Para determinar o tamanho relativo do coração de filhotes caninos com até 90 dias de idade, clinicamente saudáveis, os animais foram submetidos a exames radiográficos, semanais entre os dias dois e 30 e mensais entre os dias 30 e 90 após o nascimento, respectivamente 11, oito, seis, 10 e oito animais. Foram realizadas radiografias nas projeções ventro-dorsal (VD) e lateral direita, com os animais apropriadamente posicionados, sempre no pico inspiratório e a uma distância focofilme padronizada em 70cm. Foram avaliados, em ambas as projeções, o eixo cardíaco longo (ECL), o eixo cardíaco curto (ECC), o tamanho cardíaco vertebral (VHS), a área cardíaca (AC), a área torácica (AT) e a proporção que o coração ocupa no tórax (AC:AT). Todas as mensurações foram executadas mediante utilização do programa AUTOCAD2000®. Os valores do ECL e do VHS apresentaram elevações significativas entre os dias 16 e 23 e retornaram aos níveis apresentados durante os dias dois e nove e assim permaneceram até o dia 90, nas radiografias de ambas as projeções. Os valores do VHS, na projeção lateral, foram superiores àqueles tidos como de normalidade para cães adultos, 9,70 ± 0,5v. Na projeção VD, os valores se encontraram no intervalo normal de 10,20 ± 1,45v. Os valores do ECC não apresentaram variações significativas ao longo do estudo. Nas radiografias em posição VD, a AT aumentou de forma linear até o di

18.
MEDVEP. Rev. cient. Med. Vet. ; 8(26): 375-379, jul.-set. 2010. ilus
Artigo em Português | VETINDEX | ID: vti-1562

Resumo

O Pit Bull foi considerado uma raça espetacular para o esporte devido a suas características atléticas,assim, é de extrema importância a avaliação das características cardíacas dos animais desta raça. Aradiografia do tórax fornece informações sobre as dimensões das câmaras cardíacas, o estado do parênquimapulmonar, as vias aéreas superiores intratorácicas, a integridade anatômica das paredesda cavidade torácica e o estado pleural e da vascularização pulmonar. Outra ferramenta importantede avaliação para o sistema cardiovascular é a mensuração da pressão arterial sistêmica. Diante daausência de estudos específicos quanto à avaliação da silhueta cardíaca e da pressão arterial de cãeshígidos da raça Pit Bull, o trabalho em questão objetivou realizar avaliações radiográficas e de pressãoarterial em 10 cães adultos da raça referida, selecionados por meio de triagem de atendimento noHospital Veterinário da EV/UFG a fim de estabelecer esses parâmetros em cães desta raça. De acordocom os resultados obtidos, pode-se estabelecer que o valor de VHS para a raça é de ate 10,45 corposvertebrais. Na avaliação da pressão arterial estabeleceu-se que a pressão arterial sistólica e diastólicamédias para a raça Pit Bull é de 156,06mmHg e 77,41mmHg respectivamente(AU)


The Pit Bull was considered a spectacular breed for the sport because of its athletic features, so it isextremely important the evaluation of the heart of these animals. The chest radiograph provides informationabout the dimensions of the heart chambers, the state of the lung parenchyma, the upperairways, the anatomical integrity of the walls of the thoracic cavity and pleural status and vascularity.Another important assessment tool for the cardiovascular system is the measurement of blood pressure.Given the absence of specific studies on the evaluation of the cardiac silhouette and blood pressureof healthy Pit Bulls, the work in question aimed to perform radiographic evaluations and blood pressurein 10 adult dogs of these breed that were selected by screening care at the Veterinary Hospital ofEV / UFG to establish these parameters. According to the results obtained, we can establish that thevalue of VHS for the race is up to 10.45 vertebral bodies. In the assessment of arterial blood pressure,has been established that the systolic and diastolic blood pressure averages for the breed Pit Bull is156.06 mmHg and 77.41 mmHg respectively(AU)


Assuntos
Animais , Cães , Radiografia Torácica/veterinária , Pressão Arterial , Cães
19.
Artigo em Português | VETINDEX | ID: biblio-1485349

Resumo

O Pit Bull foi considerado uma raça espetacular para o esporte devido a suas características atléticas,assim, é de extrema importância a avaliação das características cardíacas dos animais desta raça. Aradiografia do tórax fornece informações sobre as dimensões das câmaras cardíacas, o estado do parênquimapulmonar, as vias aéreas superiores intratorácicas, a integridade anatômica das paredesda cavidade torácica e o estado pleural e da vascularização pulmonar. Outra ferramenta importantede avaliação para o sistema cardiovascular é a mensuração da pressão arterial sistêmica. Diante daausência de estudos específicos quanto à avaliação da silhueta cardíaca e da pressão arterial de cãeshígidos da raça Pit Bull, o trabalho em questão objetivou realizar avaliações radiográficas e de pressãoarterial em 10 cães adultos da raça referida, selecionados por meio de triagem de atendimento noHospital Veterinário da EV/UFG a fim de estabelecer esses parâmetros em cães desta raça. De acordocom os resultados obtidos, pode-se estabelecer que o valor de VHS para a raça é de ate 10,45 corposvertebrais. Na avaliação da pressão arterial estabeleceu-se que a pressão arterial sistólica e diastólicamédias para a raça Pit Bull é de 156,06mmHg e 77,41mmHg respectivamente


The Pit Bull was considered a spectacular breed for the sport because of its athletic features, so it isextremely important the evaluation of the heart of these animals. The chest radiograph provides informationabout the dimensions of the heart chambers, the state of the lung parenchyma, the upperairways, the anatomical integrity of the walls of the thoracic cavity and pleural status and vascularity.Another important assessment tool for the cardiovascular system is the measurement of blood pressure.Given the absence of specific studies on the evaluation of the cardiac silhouette and blood pressureof healthy Pit Bulls, the work in question aimed to perform radiographic evaluations and blood pressurein 10 adult dogs of these breed that were selected by screening care at the Veterinary Hospital ofEV / UFG to establish these parameters. According to the results obtained, we can establish that thevalue of VHS for the race is up to 10.45 vertebral bodies. In the assessment of arterial blood pressure,has been established that the systolic and diastolic blood pressure averages for the breed Pit Bull is156.06 mmHg and 77.41 mmHg respectively


Assuntos
Animais , Cães , Cães , Pressão Arterial , Radiografia Torácica/veterinária
20.
Braz. j. vet. res. anim. sci ; 41(4): 261-267, jul.-ago. 2004. ilus, graf, tab
Artigo em Português | VETINDEX | ID: vti-5127

Resumo

Para avaliação radiográfica da silhueta cardíaca têm sido propostos inúmeros métodos de mensuração com a finalidade de tentar diminuir a subjetividade da avaliação empírica. O objetivo deste estudo foi determinar o valor de VHS (vertebral heart size) em cães da raça Poodle, amplamente difundida em nosso meio, através do método de mensuração proposto por Buchanan e Bücheler . Foram selecionados trinta cães clinicamente normais, machos e fêmeas, com idades variando de um a seis anos. Os animais foram submetidos ao exame radiográfico do tórax nas projeções látero-lateral direita e ventro-dorsal. As radiografias foram avaliadas de forma empírica e posteriormente foram realizadas as medidas propostas por Buchanan e Bücheler para a silhueta cardíaca e para a profundidade e largura do tórax. A avaliação empírica não demonstrou alterações radiográficas relevantes em vinte e um dos trinta cães (70 por cento). 80 por cento dos animais tiveram suas medidas de VHS menores ou iguais a 10,5 vértebras. Os valores de VHS obtidos apresentaram distribuição normal, com média de 10,12 vértebras e desvio padrão de 0,51, sendo o valor mínimo encontrado igual a 9,2 vértebras e o máximo igual a 11,1 vértebras. Os valores da razão profundidade pela largura do tórax também apresentaram distribuição normal, com média de 0,84 e desvio padrão de 0,09, sendo o valor mínimo encontrado igual a 0,64 e o máximo igual a 1,04. 40 por cento dos cães tiveram valores de VHS superiores ao valor médio de 10,12 vértebras obtido neste trabalho o que sugere que esse valor seja rigoroso para ser utilizado como limite superior para essa raça. Para que 96,67 por cento dos animais desse estudo tivessem valores de VHS considerados inferiores ao limite superior, esse deveria ser igual a 11 vértebras... (AU)


Many measurement methods have been proposed in order to minimize the subjectivity of the empire radiographic evaluation of the cardiac silhouette. This study intended to establish the VHS (vertebral heart size) value in Poodle dogs, which are a widely spread breed, applying the Buchanan e Bucheler1 measurement method. Thirty healthy dogs, males and females, 1 to 6 years old were selected and undergone to right lateral and ventrodorsal thoracic radiographs that were first empirically evaluated. Then, Buchanan e Bucheler1 method was applied to the cardiac silhouette and thoracic depth and width. Empiric evaluation did not show any important radiographic changes in twenty one dogs (70%). VHS measurements noticed to be smaller or equal as 10.5 vertebrae in 80% of dogs. The range of minimum (9.2 vertebrae) and maximum (11.1 vertebrae) VHS values had normal distribution with a 10.12 media and 0,51 standard deviation. Normal distribution was also noticed in depth/width ratio, with a 0,84 media and a 0.09 standard deviation with minimum and maximum values of 0.64 and 1.04 respectively. 40% of dogs showed VHS values greater than the 10.12 vertebrae found in this study, it suggests that this value should be used as upper limit for Poodle dogs. The upper limit should be 11 vertebrae as 96.67% of the dogs of this study presented VHS smaller than it. Based on the results, we suggest that a 10,5 to 11 vertebrae interval should be considered the upper limit value to Poodles with 0,84 + 0,09 depth/width ratio as once only one dog showed a measure that exceeded 11 vertebrae. (AU)


Assuntos
Animais , Cães , Radiografia/métodos , Coração , Cães , Vértebras Torácicas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA