1.
J Exp Biol ; 227(4)2024 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-38284767

RESUMO

Heart rate is a crucial physiological indicator for fish, but current measurement methods are often invasive or require delicate manipulation. In this study, we introduced two non-invasive and easy-to-operate methods based on photoplethysmography, namely reflectance-type photoplethysmography (PPG) and remote photoplethysmography (rPPG), which we applied to the large yellow croaker (Larimichthys crocea). PPG showed perfect synchronization with electrocardiogram (ECG), with a Pearson's correlation coefficient of 0.99999. For rPPG, the results showed good agreement with ECG. Under active provision of green light, the Pearson's correlation coefficient was 0.966, surpassing the value of 0.947 under natural light. Additionally, the root mean square error was 0.810, which was lower than the value of 1.30 under natural light, indicating not only that the rPPG method had relatively high accuracy but also that green light may have the potential to further improve its accuracy.


Assuntos
Eletrocardiografia , Fotopletismografia , Frequência Cardíaca/fisiologia , Fotopletismografia/métodos , Processamento de Sinais Assistido por Computador
2.
Sensors (Basel) ; 24(15)2024 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-39124087

RESUMO

Transcatheter aortic valve implantation (TAVI) was initially developed for adult patients, but there is a growing interest to expand this procedure to younger individuals with longer life expectancies. However, the gradual degradation of biological valve leaflets in transcatheter heart valves (THV) presents significant challenges for this extension. This study aimed to establish a multiphysics computational framework to analyze structural and flow measurements of TAVI and evaluate the integration of optical fiber and photoplethysmography (PPG) sensors for monitoring valve function. A two-way fluid-solid interaction (FSI) analysis was performed on an idealized aortic vessel before and after the virtual deployment of the SAPIEN 3 Ultra (S3) THV. Subsequently, an analytical analysis was conducted to estimate the PPG signal using computational flow predictions and to analyze the effect of different pressure gradients and distances between PPG sensors. Circumferential strain estimates from the embedded optical fiber in the FSI model were highest in the sinus of Valsalva; however, the optimal fiber positioning was found to be distal to the sino-tubular junction to minimize bending effects. The findings also demonstrated that positioning PPG sensors both upstream and downstream of the bioprosthesis can be used to effectively assess the pressure gradient across the valve. We concluded that computational modeling allows sensor design to quantify vessel wall strain and pressure gradients across valve leaflets, with the ultimate goal of developing low-cost monitoring systems for detecting valve deterioration.


Assuntos
Próteses Valvulares Cardíacas , Humanos , Fotopletismografia/métodos , Valva Aórtica/fisiologia , Valva Aórtica/cirurgia , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Substituição da Valva Aórtica Transcateter , Hemodinâmica/fisiologia , Fibras Ópticas
3.
Sensors (Basel) ; 23(3)2023 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-36772300

RESUMO

Continuous blood pressure (BP) measurement is vital in monitoring patients' health with a high risk of cardiovascular disease. The complex and dynamic nature of the cardiovascular system can influence BP through many factors, such as cardiac output, blood vessel wall elasticity, circulated blood volume, peripheral resistance, respiration, and emotional behavior. Yet, traditional BP measurement methods in continuously estimating the BP are cumbersome and inefficient. This paper presents a novel hybrid model by integrating a convolutional neural network (CNN) as a trainable feature extractor and support vector regression (SVR) as a regression model. This model can automatically extract features from the electrocardiogram (ECG) and photoplethysmography (PPG) signals and continuously estimates the systolic blood pressure (SBP) and diastolic blood pressure (DBP). The CNN takes the correct topology of input data and establishes the relationship between ECG and PPG features and BP. A total of 120 patients with available ECG, PPG, SBP, and DBP data are selected from the MIMIC III database to evaluate the performance of the proposed model. This novel model achieves an overall Mean Absolute Error (MAE) of 1.23 ± 2.45 mmHg (MAE ± STD) for SBP and 3.08 ± 5.67 for DBP, all of which comply with the accuracy requirements of the AAMI SP10 standard.


Assuntos
Determinação da Pressão Arterial , Fotopletismografia , Humanos , Pressão Sanguínea , Fotopletismografia/métodos , Determinação da Pressão Arterial/métodos , Redes Neurais de Computação , Eletrocardiografia
4.
Sensors (Basel) ; 23(4)2023 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-36850919

RESUMO

In this paper, new features relevant to blood pressure (BP) estimation using photoplethysmography (PPG) are presented. A total of 195 features, including the proposed ones and those already known in the literature, have been calculated on a set composed of 50,000 pulses from 1080 different patients. Three feature selection methods, namely Correlation-based Feature Selection (CFS), RReliefF and Minimum Redundancy Maximum Relevance (MRMR), have then been applied to identify the most significant features for BP estimation. Some of these features have been extracted through a novel PPG signal enhancement method based on the use of the Maximal Overlap Discrete Wavelet Transform (MODWT). As a matter of fact, the enhanced signal leads to a reliable identification of the characteristic points of the PPG signal (e.g., systolic, diastolic and dicrotic notch points) by simple means, obtaining results comparable with those from purposely defined algorithms. For systolic points, mean and std of errors computed as the difference between the locations obtained using a purposely defined already known algorithm and those using the MODWT enhancement are, respectively, 0.0097 s and 0.0202 s; for diastolic points they are, respectively, 0.0441 s and 0.0486 s; for dicrotic notch points they are 0.0458 s and 0.0896 s. Hence, this study leads to the selection of several new features from the MODWT enhanced signal on every single pulse extracted from PPG signals, in addition to features already known in the literature. These features can be employed to train machine learning (ML) models useful for estimating systolic blood pressure (SBP) and diastolic blood pressure (DBP) in a non-invasive way, which is suitable for telemedicine health-care monitoring.


Assuntos
Algoritmos , Fotopletismografia , Humanos , Pressão Sanguínea , Diástole , Frequência Cardíaca
5.
Sensors (Basel) ; 23(6)2023 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-36992029

RESUMO

Monitoring diabetes saves lives. To this end, we introduce a novel, unobtrusive, and readily deployable in-ear device for the continuous and non-invasive measurement of blood glucose levels (BGLs). The device is equipped with a low-cost commercially available pulse oximeter whose infrared wavelength (880 nm) is used for the acquisition of photoplethysmography (PPG). For rigor, we considered a full range of diabetic conditions (non-diabetic, pre-diabetic, type I diabetic, and type II diabetic). Recordings spanned nine different days, starting in the morning while fasting, up to a minimum of a two-hour period after eating a carbohydrate-rich breakfast. The BGLs from PPG were estimated using a suite of regression-based machine learning models, which were trained on characteristic features of PPG cycles pertaining to high and low BGLs. The analysis shows that, as desired, an average of 82% of the BGLs estimated from PPG lie in region A of the Clarke error grid (CEG) plot, with 100% of the estimated BGLs in the clinically acceptable CEG regions A and B. These results demonstrate the potential of the ear canal as a site for non-invasive blood glucose monitoring.


Assuntos
Glicemia , Fotopletismografia , Fotopletismografia/métodos , Automonitorização da Glicemia , Oximetria/métodos , Oxigênio
6.
Sensors (Basel) ; 23(9)2023 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-37177450

RESUMO

Photoplethysmography (PPG) signals have been widely used in evaluating cardiovascular biomarkers, however, there is a lack of in-depth understanding of the remote usage of this technology and its viability for underdeveloped countries. This study aims to quantitatively evaluate the performance of a low-cost wireless PPG device in detecting ultra-short-term time-domain pulse rate variability (PRV) parameters in different postures and breathing patterns. A total of 30 healthy subjects were recruited. ECG and PPG signals were simultaneously recorded in 3 min using miniaturized wearable sensors. Four heart rate variability (HRV) and PRV parameters were extracted from ECG and PPG signals, respectively, and compared using analysis of variance (ANOVA) or Scheirer-Ray-Hare test with post hoc analysis. In addition, the data loss was calculated as the percentage of missing sampling points. Posture did not present statistical differences across the PRV parameters but a statistical difference between indicators was found. Strong variation was found for the RMSSD indicator in the standing posture. The sitting position in both breathing patterns demonstrated the lowest data loss (1.0 ± 0.6 and 1.0 ± 0.7) and the lowest percentage of different factors for all indicators. The usage of commercial PPG and BLE devices can allow the reliable extraction of the PPG signal and PRV indicators in real time.


Assuntos
Fotopletismografia , Postura , Humanos , Frequência Cardíaca/fisiologia , Voluntários Saudáveis , Respiração , Eletrocardiografia
7.
Sensors (Basel) ; 24(1)2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38202878

RESUMO

Biometric authentication is a widely used method for verifying individuals' identities using photoplethysmography (PPG) cardiac signals. The PPG signal is a non-invasive optical technique that measures the heart rate, which can vary from person to person. However, these signals can also be changed due to factors like stress, physical activity, illness, or medication. Ensuring the system can accurately identify and authenticate the user despite these variations is a significant challenge. To address these issues, the PPG signals were preprocessed and transformed into a 2-D image that visually represents the time-varying frequency content of multiple PPG signals from the same human using the scalogram technique. Afterward, the features fusion approach is developed by combining features from the hybrid convolution vision transformer (CVT) and convolutional mixer (ConvMixer), known as the CVT-ConvMixer classifier, and employing attention mechanisms for the classification of human identity. This hybrid model has the potential to provide more accurate and reliable authentication results in real-world scenarios. The sensitivity (SE), specificity (SP), F1-score, and area under the receiver operating curve (AUC) metrics are utilized to assess the model's performance in accurately distinguishing genuine individuals. The results of extensive experiments on the three PPG datasets were calculated, and the proposed method achieved ACCs of 95%, SEs of 97%, SPs of 95%, and an AUC of 0.96, which indicate the effectiveness of the CVT-ConvMixer system. These results suggest that the proposed method performs well in accurately classifying or identifying patterns within the PPG signals to perform continuous human authentication.


Assuntos
Identificação Biométrica , Dispositivos Ópticos , Humanos , Fotopletismografia , Benchmarking , Fontes de Energia Elétrica
8.
Sensors (Basel) ; 23(8)2023 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-37112125

RESUMO

Frequency estimation plays a critical role in vital sign monitoring. Methods based on Fourier transform and eigen-analysis are commonly adopted techniques for frequency estimation. Because of the nonstationary and time-varying characteristics of physiological processes, time-frequency analysis (TFA) is a feasible way to perform biomedical signal analysis. Among miscellaneous approaches, Hilbert-Huang transform (HHT) has been demonstrated to be a potential tool in biomedical applications. However, the problems of mode mixing, unnecessary redundant decomposition and boundary effect are the common deficits that occur during the procedure of empirical mode decomposition (EMD) or ensemble empirical mode decomposition (EEMD). The Gaussian average filtering decomposition (GAFD) technique has been shown to be appropriate in several biomedical scenarios and can be an alternative to EMD and EEMD. This research proposes the combination of GAFD and Hilbert transform that is termed the Hilbert-Gauss transform (HGT) to overcome the conventional drawbacks of HHT in TFA and frequency estimation. This new method is verified to be effective for the estimation of respiratory rate (RR) in finger photoplethysmography (PPG), wrist PPG and seismocardiogram (SCG). Compared with the ground truth values, the estimated RRs are evaluated to be of excellent reliability by intraclass correlation coefficient (ICC) and to be of high agreement by Bland-Altman analysis.


Assuntos
Algoritmos , Taxa Respiratória , Reprodutibilidade dos Testes , Fotopletismografia/métodos , Distribuição Normal , Processamento de Sinais Assistido por Computador
9.
Ann Noninvasive Electrocardiol ; 27(3): e12941, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35239217

RESUMO

BACKGROUND: Multiple studies have been published using a pulse oximeter's photoplethysmographic (PPG) capability to detect tissue perfusion. However, the origin of the PPG signal is still debatable. AIM: A comparative study was performed of PPG waveforms in hypertensive patients before and after treatment with antihypertensive medication. The aim of this study was to observe the changes of PPG waveforms before and after lowering blood pressure in hypertensive patients and then to detect the relationship between blood pressure and PPG waveforms. METHODS: The PPG waveforms of 60 patients with hypertension were collected. After administration of the antihypertensive medication nitroglycerin, PPG waveforms were collected again. The changes of the T3 (time3): This phase occurred between Marker 3 and Marker 4 (this phase occurs mid-diastolic) angle, before and after the antihypertensive medication treatment, were compared. The statistical analyses of two related groups were performed using the Paired t-test. RESULTS: The blood perfusion waveforms of hypertensive patients before and after antihypertensive medication administration were differently indicated with the tilt angle T3. The slope angle of the T3 phase waveform increased significantly when the blood pressure dropped to normal (-41.9 ± 16.2° vs. -25.6 ± 21.9°, p < .0001), and the tilt angle of some patients was similar to that of adults with normal blood pressure. CONCLUSION: In patients with hypertension, the tilt angle of the PPG waveform in the T3 phase increased significantly after administration of the antihypertensive medication nitroglycerin. It is worth to conduct deeper research about the relationship between hypertension and the blood perfusion of microcirculation in the diastolic period.


Assuntos
Hipertensão , Fotopletismografia , Adulto , Anti-Hipertensivos/uso terapêutico , Eletrocardiografia , Humanos , Hipertensão/tratamento farmacológico , Nitroglicerina
10.
Sensors (Basel) ; 22(22)2022 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-36433366

RESUMO

Negative and positive emotions are the risk and protective factors for the cause and prognosis of hypertension. This study aimed to use five photoplethysmography (PPG) waveform indices and affective computing (AC) to discriminate the emotional states in patients with hypertension. Forty-three patients with essential hypertension were measured for blood pressure and PPG signals under baseline and four emotional conditions (neutral, anger, happiness, and sadness), and the PPG signals were transformed into the mean standard deviation of five PPG waveform indices. A support vector machine was used as a classifier. The performance of the classifier was verified by using resubstitution and six-fold cross-validation (CV) methods. Feature selectors, including full search and genetic algorithm (GA), were used to select effective feature combinations. Traditional statistical analyses only differentiated between the emotional states and baseline, whereas AC achieved 100% accuracy in distinguishing between the emotional states and baseline by using the resubstitution method. AC showed high accuracy rates when used with 10 waveform features in distinguishing the records into two, three, and four classes by applying a six-fold CV. The GA feature selector further boosted the accuracy to 78.97%, 74.22%, and 67.35% in two-, three-, and four-class differentiation, respectively. The proposed AC achieved high accuracy in categorizing PPG records into distinct emotional states with features extracted from only five waveform indices. The results demonstrated the effectiveness of the five indices and the proposed AC in patients with hypertension.


Assuntos
Hipertensão , Fotopletismografia , Humanos , Fotopletismografia/métodos , Máquina de Vetores de Suporte , Pressão Sanguínea , Emoções , Hipertensão/diagnóstico
11.
Sensors (Basel) ; 22(13)2022 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-35808182

RESUMO

Heart Rate Variability (HRV) has become an important risk assessment tool when diagnosing illnesses related to heart health. HRV is typically measured with an electrocardiogram; however, there are multiple studies that use Photoplethysmography (PPG) instead. Measuring HRV with video is beneficial as a non-invasive, hands-free alternative and represents a more accessible approach. We developed a methodology to extract HRV from video based on face detection algorithms and color augmentation. We applied this methodology to 45 samples. Signals obtained from PPG and video recorded an average mean error of less than 1 bpm when measuring the heart rate of all subjects. Furthermore, utilizing PPG and video, we computed 61 variables related to HRV. We compared each of them with three correlation metrics (i.e., Kendall, Pearson, and Spearman), adjusting them for multiple comparisons with the Benjamini-Hochberg method to control the false discovery rate and to retrieve the q-value when considering statistical significance lower than 0.5. Using these methods, we found significant correlations for 38 variables (e.g., Heart Rate, 0.991; Mean NN Interval, 0.990; and NN Interval Count, 0.955) using time-domain, frequency-domain, and non-linear methods.


Assuntos
Eletrocardiografia , Fotopletismografia , Algoritmos , Eletrocardiografia/métodos , Mãos , Frequência Cardíaca/fisiologia , Humanos , Fotopletismografia/métodos
12.
Sensors (Basel) ; 22(13)2022 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-35808352

RESUMO

The past few decades have seen ongoing development of continuous glucose monitoring (CGM) systems that are noninvasive and accurately measure blood glucose levels. The conventional finger-prick method, though accurate, is not feasible for use multiple times a day, as it is painful and test strips are expensive. Although minimally invasive and noninvasive CGM systems have been introduced into the market, they are expensive and require finger-prick calibrations. As the diabetes trend is high in low- and middle-income countries, a cost-effective and easy-to-use noninvasive glucose monitoring device is the need of the hour. This review paper briefly discusses the noninvasive glucose measuring technologies and their related research work. The technologies discussed are optical, transdermal, and enzymatic. The paper focuses on Near Infrared (NIR) technology and NIR Photoplethysmography (PPG) for blood glucose prediction. Feature extraction from PPG signals and glucose prediction with machine learning methods are discussed. The review concludes with key points and insights for future development of PPG NIR-based blood glucose monitoring systems.


Assuntos
Automonitorização da Glicemia , Glicemia , Automonitorização da Glicemia/métodos , Monitorização Fisiológica/métodos , Fotopletismografia/métodos , Tecnologia
13.
Sensors (Basel) ; 22(24)2022 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-36560324

RESUMO

The quality of heart rate (HR) measurements extracted from human photoplethysmography (PPG) signals are known to deteriorate under appreciable human motion. Auxiliary signals, such as accelerometer readings, are usually employed to detect and suppress motion artifacts. A 2019 study by Yifan Zhang and his coinvestigatorsused the noise components extracted from an infrared PPG signal to denoise a green PPG signal from which HR was extracted. Until now, this approach was only tested on "micro-motion" such as finger tapping. In this study, we extend this technique to allow accurate calculation of HR under high-intensity full-body repetitive "macro-motion". Our Dual Wavelength (DWL) framework was tested on PPG data collected from 14 human participants while running on a treadmill. The DWL method showed the following attributes: (1) it performed well under high-intensity full-body repetitive "macro-motion", exhibiting high accuracy in the presence of motion artifacts (as compared to the leading accelerometer-dependent HR calculation techniques TROIKA and JOSS); (2) it used only PPG signals; auxiliary signals such as accelerometer signals were not needed; and (3) it was computationally efficient, hence implementable in wearable devices. DWL yielded a Mean Absolute Error (MAE) of 1.22|0.57 BPM, Mean Absolute Error Percentage (MAEP) of 0.95|0.38%, and performance index (PI) (which is the frequency, in percent, of obtaining an HR estimate that is within ±5 BPM of the HR ground truth) of 95.88|4.9%. Moreover, DWL yielded a short computation period of 3.0|0.3 s to process a 360-second-long run.


Assuntos
Algoritmos , Corrida , Humanos , Frequência Cardíaca/fisiologia , Fotopletismografia/métodos , Processamento de Sinais Assistido por Computador , Artefatos
14.
Sensors (Basel) ; 22(12)2022 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-35746236

RESUMO

This study proposed a noninvasive blood glucose estimation system based on dual-wavelength photoplethysmography (PPG) and bioelectrical impedance measuring technology that can avoid the discomfort created by conventional invasive blood glucose measurement methods while accurately estimating blood glucose. The measured PPG signals are converted into mean, variance, skewness, kurtosis, standard deviation, and information entropy. The data obtained by bioelectrical impedance measuring consist of the real part, imaginary part, phase, and amplitude size of 11 types of frequencies, which are converted into features through principal component analyses. After combining the input of seven physiological features, the blood glucose value is finally obtained as the input of the back-propagation neural network (BPNN). To confirm the robustness of the system operation, this study collected data from 40 volunteers and established a database. From the experimental results, the system has a mean squared error of 40.736, a root mean squared error of 6.3824, a mean absolute error of 5.0896, a mean absolute relative difference of 4.4321%, and a coefficient of determination (R Squared, R2) of 0.997, all of which fall within the clinically accurate region A in the Clarke error grid analyses.


Assuntos
Glicemia , Fotopletismografia , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Impedância Elétrica , Humanos , Redes Neurais de Computação , Fotopletismografia/métodos
15.
Sensors (Basel) ; 21(9)2021 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-33919251

RESUMO

In human emotion estimation using an electroencephalogram (EEG) and heart rate variability (HRV), there are two main issues as far as we know. The first is that measurement devices for physiological signals are expensive and not easy to wear. The second is that unnecessary physiological indexes have not been removed, which is likely to decrease the accuracy of machine learning models. In this study, we used single-channel EEG sensor and photoplethysmography (PPG) sensor, which are inexpensive and easy to wear. We collected data from 25 participants (18 males and 7 females) and used a deep learning algorithm to construct an emotion classification model based on Arousal-Valence space using several feature combinations obtained from physiological indexes selected based on our criteria including our proposed feature selection methods. We then performed accuracy verification, applying a stratified 10-fold cross-validation method to the constructed models. The results showed that model accuracies are as high as 90% to 99% by applying the features selection methods we proposed, which suggests that a small number of physiological indexes, even from inexpensive sensors, can be used to construct an accurate emotion classification model if an appropriate feature selection method is applied. Our research results contribute to the improvement of an emotion classification model with a higher accuracy, less cost, and that is less time consuming, which has the potential to be further applied to various areas of applications.


Assuntos
Algoritmos , Eletroencefalografia , Nível de Alerta , Emoções , Feminino , Frequência Cardíaca , Humanos , Masculino
16.
Sensors (Basel) ; 21(14)2021 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-34300657

RESUMO

Continuous monitoring of blood-glucose concentrations is essential for both diabetic and nondiabetic patients to plan a healthy lifestyle. Noninvasive in vivo blood-glucose measurements help reduce the pain of piercing human fingertips to collect blood. To facilitate noninvasive measurements, this work proposes a Monte Carlo photon simulation-based model to estimate blood-glucose concentration via photoplethysmography (PPG) on the fingertip. A heterogeneous finger model was exposed to light at 660 nm and 940 nm in the reflectance mode of PPG via Monte Carlo photon propagation. The bio-optical properties of the finger model were also deduced to design the photon simulation model for the finger layers. The intensities of the detected photons after simulation with the model were used to estimate the blood-glucose concentrations using a supervised machine-learning model, XGBoost. The XGBoost model was trained with synthetic data obtained from the Monte Carlo simulations and tested with both synthetic and real data (n = 35). For testing with synthetic data, the Pearson correlation coefficient (Pearson's r) of the model was found to be 0.91, and the coefficient of determination (R2) was found to be 0.83. On the other hand, for tests with real data, the Pearson's r of the model was 0.85, and R2 was 0.68. Error grid analysis and Bland-Altman analysis were also performed to confirm the accuracy. The results presented herein provide the necessary steps for noninvasive in vivo blood-glucose concentration estimation.


Assuntos
Fótons , Fotopletismografia , Simulação por Computador , Glucose , Humanos , Método de Monte Carlo
17.
Sensors (Basel) ; 21(13)2021 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-34202597

RESUMO

BACKGROUND: Feature extraction from photoplethysmography (PPG) signals is an essential step to analyze vascular and hemodynamic information. Different morphologies of PPG waveforms from different measurement sites appear. Various phenomena of missing or ambiguous features exist, which limit subsequent signal processing. METHODS: The reasons that cause missing or ambiguous features of finger and wrist PPG pulses are analyzed based on the concept of component waves from pulse decomposition. Then, a systematic approach for missing-feature imputation and ambiguous-feature resolution is proposed. RESULTS: From the experimental results, with the imputation and ambiguity resolution technique, features from 35,036 (98.7%) of 35,502 finger PPG cycles and 36307 (99.1%) of 36,652 wrist PPG cycles can be successfully identified. The extracted features became more stable and the standard deviations of their distributions were reduced. Furthermore, significant correlations up to 0.92 were shown between the finger and wrist PPG waveforms regarding the positions and widths of the third to fifth component waves. CONCLUSION: The proposed missing-feature imputation and ambiguous-feature resolution solve the problems encountered during PPG feature extraction and expand the feature availability for further processing. More intrinsic properties of finger and wrist PPG are revealed. The coherence between the finger and wrist PPG waveforms enhances the applicability of the wrist PPG.


Assuntos
Fotopletismografia , Punho , Dedos , Frequência Cardíaca , Processamento de Sinais Assistido por Computador
18.
Sensors (Basel) ; 21(23)2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34883817

RESUMO

Previously published photoplethysmography-(PPG) based non-invasive blood glucose (NIBG) measurements have not yet been validated over 500 subjects. As illustrated in this work, we increased the number subjects recruited to 2538 and found that the prediction accuracy (the ratio in zone A of Clarke's error grid) reduced to undesirable 60.6%. We suspect the low prediction accuracy induced by larger sample size might arise from the physiological diversity of subjects, and one possibility is that the diversity might originate from medication. Therefore, we split the subjects into two cohorts for deep learning: with and without medication (1682 and 856 recruited subjects, respectively). In comparison, the cohort training for subjects without any medication had approximately 30% higher prediction accuracy over the cohort training for those with medication. Furthermore, by adding quarterly (every 3 months) measured glycohemoglobin (HbA1c), we were able to significantly boost the prediction accuracy by approximately 10%. For subjects without medication, the best performing model with quarterly measured HbA1c achieved 94.3% prediction accuracy, RMSE of 12.4 mg/dL, MAE of 8.9 mg/dL, and MAPE of 0.08, which demonstrates a very promising solution for NIBG prediction via deep learning. Regarding subjects with medication, a personalized model could be a viable means of further investigation.


Assuntos
Glicemia , Aprendizado Profundo , Estudos de Coortes , Hemoglobinas Glicadas , Humanos , Fotopletismografia
19.
Sensors (Basel) ; 21(24)2021 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-34960512

RESUMO

With the continued development and rapid growth of wearable technologies, PPG has become increasingly common in everyday consumer devices such as smartphones and watches. There is, however, minimal knowledge on the effect of the contact pressure exerted by the sensor device on the PPG signal and how it might affect its morphology and the parameters being calculated. This study explores a controlled in vitro study to investigate the effect of continually applied contact pressure on PPG signals (signal-to-noise ratio (SNR) and 17 morphological PPG features) from an artificial tissue-vessel phantom across a range of simulated blood pressure values. This experiment confirmed that for reflectance PPG signal measurements for a given anatomical model, there exists an optimum sensor contact pressure (between 35.1 mmHg and 48.1 mmHg). Statistical analysis shows that temporal morphological features are less affected by contact pressure, lending credit to the hypothesis that for some physiological parameters, such as heart rate and respiration rate, the contact pressure of the sensor is of little significance, whereas the amplitude and geometric features can show significant change, and care must be taken when using morphological analysis for parameters such as SpO2 and assessing autonomic responses.


Assuntos
Fotopletismografia , Dispositivos Eletrônicos Vestíveis , Frequência Cardíaca , Saturação de Oxigênio , Imagens de Fantasmas
20.
Sensors (Basel) ; 21(18)2021 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-34577222

RESUMO

Photoplethysmography (PPG) as an additional biosignal for a seizure detector has been underutilized so far, which is possibly due to its susceptibility to motion artifacts. We investigated 62 focal seizures from 28 patients with electrocardiography-based evidence of ictal tachycardia (IT). Seizures were divided into subgroups: those without epileptic movements and those with epileptic movements not affecting and affecting the extremities. PPG-based heart rate (HR) derived from a wrist-worn device was calculated for sections with high signal quality, which were identified using spectral entropy. Overall, IT based on PPG was identified in 37 of 62 (60%) seizures (9/19, 7/8, and 21/35 in the three groups, respectively) and could be found prior to the onset of epileptic movements affecting the extremities in 14/21 seizures. In 30/37 seizures, PPG-based IT was in good temporal agreement (<10 s) with ECG-based IT, with an average delay of 5.0 s relative to EEG onset. In summary, we observed that the identification of IT by means of a wearable PPG sensor is possible not only for non-motor seizures but also in motor seizures, which is due to the early manifestation of IT in a relevant subset of focal seizures. However, both spontaneous and epileptic movements can impair PPG-based seizure detection.


Assuntos
Fotopletismografia , Dispositivos Eletrônicos Vestíveis , Eletrocardiografia , Eletroencefalografia , Frequência Cardíaca , Humanos , Convulsões/diagnóstico , Processamento de Sinais Assistido por Computador , Taquicardia