1.
Genet Med ; 26(2): 101023, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37947183

RESUMO

PURPOSE: We sought to delineate a multisystem disorder caused by recessive cysteine-rich with epidermal growth factor-like domains 1 (CRELD1) gene variants. METHODS: The impact of CRELD1 variants was characterized through an international collaboration utilizing next-generation DNA sequencing, gene knockdown, and protein overexpression in Xenopus tropicalis, and in vitro analysis of patient immune cells. RESULTS: Biallelic variants in CRELD1 were found in 18 participants from 14 families. Affected individuals displayed an array of phenotypes involving developmental delay, early-onset epilepsy, and hypotonia, with about half demonstrating cardiac arrhythmias and some experiencing recurrent infections. Most harbored a frameshift in trans with a missense allele, with 1 recurrent variant, p.(Cys192Tyr), identified in 10 families. X tropicalis tadpoles with creld1 knockdown displayed developmental defects along with increased susceptibility to induced seizures compared with controls. Additionally, human CRELD1 harboring missense variants from affected individuals had reduced protein function, indicated by a diminished ability to induce craniofacial defects when overexpressed in X tropicalis. Finally, baseline analyses of peripheral blood mononuclear cells showed similar proportions of immune cell subtypes in patients compared with healthy donors. CONCLUSION: This patient cohort, combined with experimental data, provide evidence of a multisystem clinical syndrome mediated by recessive variants in CRELD1.


Assuntos
Transtornos do Neurodesenvolvimento , Reinfecção , Humanos , Leucócitos Mononucleares , Síndrome , Fenótipo , Arritmias Cardíacas/genética , Transtornos do Neurodesenvolvimento/genética , Moléculas de Adesão Celular/genética , Proteínas da Matriz Extracelular/genética
2.
Artigo em Inglês | MEDLINE | ID: mdl-38894503

RESUMO

INTRODUCTION: We aimed to study whether KardiaMobile 6L 30-second capture technology could shorten ECG collection time compared to standard 12L ECG without compromising data usability. METHODS: A single-center, non-randomized trial was performed on patients presenting for follow-up visits to the electrophysiology (EP) clinic. Providers in the KardiaMobile 6L group were allowed to request a standard 12L if the 6L was deemed insufficient for clinical care. Room utilization times, defined as the time from medical assistant room entry to exit, were compared for each group. RESULTS: There were 100 patients in the study, with 50 in each arm. Average room utilization time for the 12L group and 6L groups were 10.33 ± 2.2 and 7.27 ± 1.93 min, respectively (p < .001). In 8 (16%) visits for the 6L group, an additional 12L was requested. CONCLUSION: For EP follow-up visits, clinic utilization time was significantly reduced with the KardiaMobile 6L compared to the 12L ECG with infrequent need for an additional 12L.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38967399

RESUMO

BACKGROUND: The annual incidence of sudden cardiac death is over 300,000 in the United States (US). Historically, inpatient implantation of secondary prevention implantable cardioverter defibrillator (ICD) has been variable and subject to healthcare disparities. OBJECTIVE: To evaluate contemporary practice trends of inpatient secondary prevention ICD implants within the US on the basis of race, sex, and socioeconomic status (SES). METHODS: The study is a retrospective analysis of the National Inpatient Sample from 2016 to 2020 of adult discharges with a primary diagnosis of ventricular tachycardia (VT), ventricular flutter, and fibrillation (VF). Adjusted ICD implantation rates based on race, sex, and SES and associated temporal trends were calculated using multivariate regression. RESULTS: A total of 193,600 primary VT/VF discharges in the NIS were included in the cohort, of which 57,895 (29.9%) had ICD placement. There was a significant racial and ethnic disparity in ICD placement for Black, Hispanic, Asian, and Native American patients as compared to White patients; adjusted odds ratio (aOR): 0.86 [p < .01], 0.90 [p  =  .03], 0.81[p < .01], 0.45 [p < .01], respectively. Female patients were also less likely to receive an ICD compared to male patients (aOR: 0.75, p < .01). Disparities in ICD placement remained stable over the study period (ptrend ≥ .05 in all races, both sexes and income categories). CONCLUSION: Racial, sex, and SES disparities persisted for secondary prevention ICD implants in the US. An investigation into contributing factors and subsequent approaches are needed to address the modifiable causes of disparities in ICD implantation as these trends have not improved compared to historic data.

4.
Attach Hum Dev ; 26(3): 253-271, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38989772

RESUMO

This study examined the significance of a novel coding system for evaluating hyperactivation, deactivation, and anomalous content in the Attachment Script Assessment for romantic relationship functioning. In a sample of 208 couples (69% White, Mage 28.7 years), we tested whether ASA hyperactivation and deactivation were associated with theoretically relevant correlates, including observed behavior, parasympathetic reactivity, self-reported affective reactivity to conflict, and relationship satisfaction. Exploratory analyses examined associations of secure base script knowledge (SBSK) and anomalous content with these outcomes. ASA hyperactivation and deactivation were associated with behavioral, physiological, and self-reported functioning in theory-consistent ways. Anomalous content was not associated with romantic functioning. SBSK was associated with satisfaction, but this was not robust to covariates. Findings support the predictive validity of the hyperactivation and deactivation dimensions and suggest that these scales complement SBSK, enabling researchers to assess a wider range of behavioral and physiological indicators associated with distinctive forms of attachment insecurity.


Assuntos
Relações Interpessoais , Apego ao Objeto , Satisfação Pessoal , Humanos , Masculino , Feminino , Adulto , Adulto Jovem
5.
Psychother Res ; : 1-15, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38285175

RESUMO

OBJECTIVE: We evaluated whether respiratory sinus arrhythmia (RSA) reactivity and resting RSA-physiological markers reflecting the increase in heart rate with inspiration and decrease during expiration related to parasympathetic influence on the heart-are modifiable and predict symptom change during youth psychotherapy. Methods: Diverse youth (N = 158; ages 7-15; 48.1% female) received the Modular Approach to Therapy for Children and completed pre-treatment (pre), post-treatment (post), and 18-months postbaseline (18Mo) assessments. We measured resting RSA, RSA reactivity during stress induction, and psychopathology symptoms. Results: Pre-to-post and pre-to-18Mo, reactivity decreased, and resting RSA increased. Changes in reactivity and resting RSA, separately, did not predict reduced psychopathology. Yet, decreased reactivity combined with increased resting RSA predicted reduced psychopathology over time, suggesting that observed RSA changes were beneficial for some. Higher dosage of a module utilizing slow-breathing, muscle-relaxation, and imagery predicted greater pre-to-18Mo changes in reactivity and resting RSA, whereas a similar module with less emphasis on slow-breathing did not. Conclusions: Findings raise the possibility that youth reactivity and resting RSA could be modifiable during cognitive behavioral therapy and contribute to the amelioration of psychopathology. More studies are needed to determine whether resting RSA and RSA reactivity are modifiable indices of symptom change in slow-breathing practices and psychotherapy. CLINICALTRIALS.GOV IDENTIFIER: NCT03153904, registered May 15, 2017.

6.
Medicina (Kaunas) ; 60(2)2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38399551

RESUMO

Background and Objectives: Atrial fibrillation (AF), a prevalent cardiac arrhythmia, significantly impacts the quality of life of those affected. The preferred treatment for symptomatic AF, particularly when pharmacological methods fall short, is catheter ablation with pulmonary vein isolation (PVI). While common pulmonary vein (PV) anatomical variants, such as the right accessory pulmonary vein and the common ostium of left pulmonary veins (LCPV), have been studied extensively, their impact on the long-term outcome of PVI is known to be minimal. However, data on less common anomalies, like the common ostium of the left and right inferior pulmonary vein (CIPV), remain scarce in the medical literature. This report aims to shed light on the challenges and outcomes of catheter ablation in a patient with a rare CIPV anomaly. By presenting this case, we contribute to the limited knowledge about the management of such unique anatomical variations in AF treatment and discuss the importance of individualized treatment approaches. Case Presentation: We present a case involving a 56-year-old male diagnosed with AF in 2018. Initial PVI treatment was successful, but the patient experienced symptom recurrence after three years. A preprocedural CT scan before the second ablation revealed a CIPV anomaly. During the repeat procedure, a right superior pulmonary vein (RSPV) reisolation was performed due to identified gaps in the previous ablation line. Post-procedure, the patient maintained a sinus rhythm and reported no further symptoms. Conclusions: This case highlights the importance of recognizing rare PV anatomies like CIPV in the effective management of AF. Tailored ablation strategies, accounting for unique anatomical conditions, can lead to successful long-term outcomes, reinforcing the need for personalized approaches in AF treatment, especially in cases involving complex anatomical variations.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Masculino , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Qualidade de Vida , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
7.
Biochem Biophys Res Commun ; 649: 55-61, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36745970

RESUMO

Brugada syndrome is an inherited cardiac arrythmia causes sudden death usually associated with loss-of-function mutations of SCN5A, a gene encodes α subunit of cardiac sodium channel Nav1.5 which plays key role in cardiac function. SCN5A mutation screen is often applied to diagnosis of Brugada syndrome, while its genetic etiology remains not fully understood. In present study, we performed sequence analysis of SCN5A gene in a Chinese Han family with Brugada syndrome, and found a novel heterozygous mutation (c.4969 C > T, p.Leu1657Phe). Functional electrophysiological study showed that the mutation reduced ∼60% sodium current density and largely reduced Nav1.5 activation (positively shifted activation curve by 13.93 mV), which are the key features for the pathogenesis of Brugada syndrome. However, the mutation enhanced Nav1.5 function as it slightly decreased inactivation (positively shifted inactivation curve by 7.4 mV) and accelerated recovery (decreased fast recovery by 1.39 ms). In addition, the mutation acts in a dominant negatively manner as it reduced ∼49% sodium current densities in heterozygous state. In conclusion, the study describes a novel SCN5A mutation of p.Leu1657Phe associated with Brugada syndrome, the mutation reduced current density in a dominant negative manner and altered gating kinetics, which will benefit early clinical diagnosis of Brugada syndrome.


Assuntos
Síndrome de Brugada , Canal de Sódio Disparado por Voltagem NAV1.5 , Humanos , Síndrome de Brugada/genética , População do Leste Asiático , Mutação , Mutação de Sentido Incorreto , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Sódio/metabolismo
8.
Mol Genet Metab ; 140(4): 107733, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37979236

RESUMO

BACKGROUND: Systemic primary carnitine deficiency (PCD) is characterized by cardiomyopathy and arrhythmia. Without carnitine supplementation, progression is usually towards fatal cardiac decompensation. While the cardiomyopathy is most likely secondary to energy deficiency, the mechanism of arrhythmia is unclear, and may be related to a short QT interval. OBJECTIVE: We aim to describe rhythmic manifestations at diagnosis and with carnitine supplementation. METHODS: French patients diagnosed for PCD were retrospectively included. Clinical and para clinical data at diagnosis and during follow-up were collected. Electrocardiograms with QT interval measurements were blinded reviewed by two paediatric cardiologists. RESULTS: Nineteen patients (median age at diagnosis 2.3 years (extremes 0.3-28.9)) followed in 8 French centres were included. At diagnosis, 21% of patients (4/19) had arrhythmia (2 ventricular fibrillations, 1 ventricular tachycardia and 1 sudden death), and 84% (16/19) had cardiomyopathy. Six electrocardiograms before treatment out of 11 available displayed a short QT (QTc < 340 ms). Median corrected QTc after carnitine supplementation was 404 ms (extremes 341-447) versus 350 ms (extremes 282-421) before treatment (p < 0.001). The whole QTc was prolonged, and no patient reached the criterion of short QT syndrome with carnitine supplementation. Three patients died, probably from rhythmic cause without carnitine supplementation (two extra-hospital sudden deaths and one non-recoverable rhythmic storm before carnitine supplementation), whereas no rhythmic complication occurred in patients with carnitine supplementation. CONCLUSION: PCD is associated with shortening of the QT interval inducing severe arrhythmia. A potential explanation would be a toxic effect of accumulated fatty acid and metabolites on ionic channels embedded in the cell membrane. Carnitine supplementation normalizes the QTc and prevents arrhythmia. Newborn screening of primary carnitine deficiency would prevent avoidable deaths.


Assuntos
Cardiomiopatias , Síndrome do QT Longo , Recém-Nascido , Criança , Humanos , Pré-Escolar , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Estudos Retrospectivos , Arritmias Cardíacas/complicações , Cardiomiopatias/complicações , Carnitina/metabolismo , Eletrocardiografia/efeitos adversos
9.
J Cardiovasc Electrophysiol ; 34(8): 1622-1629, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37393602

RESUMO

INTRODUCTION: Posterior wall isolation (PWI) combined with pulmonary vein isolation (PVI) has proven effective for persistent atrial fibrillation (AF). However, when performing PWI, creating transmural lesions with subendocardial ablation is sometimes difficult. Endocardial unipolar voltage amplitude had a higher sensitivity than bipolar voltage mapping for identifying intramural viable myocardium in the atria. In this study, we aimed to retrospectively investigate the correlation between the residual potential in the posterior wall (PW) following PWI for persistent AF and atrial arrhythmia recurrence using endocardial unipolar voltage. METHODS: This was a single-center observational study. Patients who underwent PVI and PWI for persistent AF in the first procedure between March 2018 and December 2021 at the Tokyo Metropolitan Hiroo Hospital were included in this study. The patients were divided into two groups based on the presence of residual unipolar PW potentials after PWI with a cutoff of 1.08 mV and the recurrence of atrial arrhythmias was compared. RESULTS: In total, 109 patients were included in the analysis. Forty-three patients had residual unipolar potentials after PWI and 66 patients had no residual unipolar potentials. The atrial arrhythmia recurrence rate was significantly higher in the group with residual unipolar potential (41.8% vs. 17.9%, p = 0.003). The residual unipolar potential was an independent predictor of recurrence (odds ratio: 4.53; confidence interval: 1.67-12.3, p = 0.003). CONCLUSION: Residual unipolar potential after PWI for persistent AF is associated with recurrent atrial arrhythmias.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva , Átrios do Coração/cirurgia , Veias Pulmonares/cirurgia
10.
Strahlenther Onkol ; 199(7): 621-630, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37285038

RESUMO

BACKGROUND: Single-session cardiac stereotactic radiation therapy (SBRT) has demonstrated promising results for patients with refractory ventricular tachycardia (VT). However, the full safety profile of this novel treatment remains unknown and very limited data from prospective clinical multicenter trials are available. METHODS: The prospective multicenter multiplatform RAVENTA (radiosurgery for ventricular tachycardia) study assesses high-precision image-guided cardiac SBRT with 25 Gy delivered to the VT substrate determined by high-definition endocardial and/or epicardial electrophysiological mapping in patients with refractory VT ineligible for catheter ablation and an implanted cardioverter defibrillator (ICD). Primary endpoint is the feasibility of full-dose application and procedural safety (defined as an incidence of serious [grade ≥ 3] treatment-related complications ≤ 5% within 30 days after therapy). Secondary endpoints comprise VT burden, ICD interventions, treatment-related toxicity, and quality of life. We present the results of a protocol-defined interim analysis. RESULTS: Between 10/2019 and 12/2021, a total of five patients were included at three university medical centers. In all cases, the treatment was carried out without complications. There were no serious potentially treatment-related adverse events and no deterioration of left ventricular ejection fraction upon echocardiography. Three patients had a decrease in VT episodes during follow-up. One patient underwent subsequent catheter ablation for a new VT with different morphology. One patient with local VT recurrence died 6 weeks after treatment in cardiogenic shock. CONCLUSION: The interim analysis of the RAVENTA trial demonstrates early initial feasibility of this new treatment without serious complications within 30 days after treatment in five patients. Recruitment will continue as planned and the study has been expanded to further university medical centers. TRIAL REGISTRATION NUMBER: NCT03867747 (clinicaltrials.gov). Registered March 8, 2019. Study start: October 1, 2019.


Assuntos
Radiocirurgia , Taquicardia Ventricular , Humanos , Radiocirurgia/métodos , Volume Sistólico , Estudos Prospectivos , Qualidade de Vida , Estudos de Viabilidade , Função Ventricular Esquerda , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
11.
Pacing Clin Electrophysiol ; 46(2): 161-168, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36588339

RESUMO

BACKGROUND: Catheter ablation is an effective treatment for atrial fibrillation (AF,) but arrhythmia recurrence occurs in a relevant number of patients. Mechanisms of late occurring arrhythmias after ablation procedures are not fully understood. We analyzed electrophysiological mechanisms of early and late arrhythmia recurrences in patients who underwent radiofrequency-based catheter ablation of AF. METHODS AND RESULTS: Consecutive patients who underwent repeat ablation procedures after initial pulmonary vein isolation (PVI) for symptomatic arrhythmia recurrence were analyzed. A total of 110 consecutive patients who underwent catheter ablation for paroxysmal (79%) or persistent AF (21%) were included. Forty-seven patients suffered from early arrhythmia recurrence (group #1: 3-24 months), 29 patients from mid-term arrhythmia recurrences (group #2: 2-5 years), and 34 patients from late arrhythmia recurrences (group #3: > 5 years). Electrical PV reconnection was found in 98% in group #1, 72% in group #2 and 56% in group #3 (p < .001). Mode of arrhythmia recurrence was organized tachycardia in 25%, 28%, and 65% of patients in groups #1, #2, and #3 (p = .001), respectively. Patients with late arrhythmia recurrence had more pronounced left atrial low voltage as compared to patients with early arrhythmia recurrence based on two published scoring system. CONCLUSION: Electrical PV reconnection was found in the majority of patients with early AF recurrence after PVI. In patients with late arrhythmia recurrences this mechanism may play an inferior role, with many patients presenting without PV reconnection, but with LA structural alterations. Thus, early and late occurring arrhythmia recurrence after catheter ablation may be the same symptom of different diseases.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Recidiva , Átrios do Coração , Resultado do Tratamento , Ablação por Cateter/métodos
12.
Heart Vessels ; 38(5): 731-739, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36443457

RESUMO

Syncope prognosis is related to both its etiology and comorbidities, with cardiac syncope (CS) having higher risks for mortality and cardiovascular events than syncope of non-cardiac causes. Although a novel insertable cardiac monitor (ICM) is an effective diagnostic tool for unexplained syncope, decision regarding ICM implantation with a high pre-test likelihood of CS should contribute to economic cost reduction and avoidance of unnecessary complications. This study aimed to investigate clinical factors associated with CS after ICM implantation in patients with unexplained syncope. This retrospective observational study included 31 consecutive patients with ICM implantation for syncope between September 2016 and August 2021. The initial examinations for syncope included a detailed history, physical examination, blood tests, 12-lead electrocardiograms, and transthoracic echocardiography. Of the 31 patients, 13 (41.9%) experienced recurrent CS during follow-up (676 ± 469 days). Among several clinical factors, syncope-related minor injuries (p = 0.017) and higher brain natriuretic peptide (BNP; p = 0.043) levels were significantly associated with CS. Moreover, multivariable analysis showed that both syncope-related minor injuries (odds ratio, 11.2; 95% confidence interval, 1.4-88.4; p = 0.022) and BNP higher than 64.0 pg/mL (odds ratio, 7.0; 95% confidence interval, 1.1-44.2; p = 0.038) were independent predictors of CS after ICM implantation. In conclusion, a history of minor injury secondary to syncope and higher BNP levels were independent CS predictors in patients receiving ICM for syncope. These results emphasized the utility of ICM implantation early in the diagnostic journey of patients presenting with CS predictors requiring specific treatments.


Assuntos
Eletrocardiografia , Síncope , Humanos , Prognóstico , Estudos Retrospectivos , Síncope/diagnóstico , Síncope/epidemiologia , Síncope/etiologia , Eletrocardiografia Ambulatorial
13.
Acta Anaesthesiol Scand ; 67(3): 284-292, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36508160

RESUMO

BACKGROUND: Prolonged corrected QT interval (QTc) has been linked to risk of arrhythmias and mortality in the general population. Pre-operative electrocardiography is often obtained for patient-and procedural cardiovascular risk assessment. The aim of this study was to investigate the association of pre-operative QTc and all-cause mortality in a non-cardiac surgical cohort. METHODS: A retrospective study of all patients over 18 years undergoing non-cardiac surgery at Landspitali-the National University Hospital in Iceland between 2 January 2005 to 31 December 2015, with follow-up through 20 May 2016. Patients were separated into five categories according to their pre-operative QTc interval ≤ 379, 380-439 (reference group), 440-479, 480-519 and ≥520 ms. Primary outcome was long-term mortality and secondary outcome was 30-day mortality. RESULTS: A total of 10,209 surgeries for 10,209 individuals were included. The median follow-up for mortality was 2691 days (interquartile range [IQR] 1620-3705 days). Patients with longer QTc interval had a higher comorbidity burden, were more likely to undergo emergency surgery and were often prescribed cardiac medications. After adjustment for confounding variables, the hazard ratio (HR) for long-term mortality compared with reference (QTc 380-439 ms) was 0.85 [CI: 0.66-1.09] for QTc ≤379, 1.08 [CI: 0.99-1.17] for QTc 440-479 ms, 1.26 [CI: 1.10-1.43] for QTc between 480 and 519 ms and 0.97 [CI: 0.78-1.21] for QTc ≥520 ms. When compared with reference, only patients with QTc interval between 480 and 519 ms had higher odds ratio for 30-day mortality as odds ratio for other groups were following; 1.12 [CI: 0.18-3.8] for ≤379 ms, 1.03 [CI: 0.70-1.51] for QTc 440-479 ms, 1.64 [CI: 1.02-2.60] for QTc 480-519 ms and 0.98 [0.44-2.06] for QTc ≥520 ms. CONCLUSION: Pre-operative QTc between 480 and 519 ms is associated with both higher long-term and 30-day mortality after non-cardiac surgery. The results suggest that this could reflect an underlying cardiovascular risk.


Assuntos
Síndrome do QT Longo , Humanos , Fatores de Risco , Estudos Retrospectivos , Arritmias Cardíacas , Comorbidade , Eletrocardiografia
14.
Dev Psychobiol ; 65(7): e22428, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37860903

RESUMO

Porges' polyvagal theory (1991) proposes that the activity of the vagal nerve modulates moment-by-moment changes in adaptive behavior during stress. However, most work, including research with infants, has only examined vagal changes at low temporal resolutions, averaging 30+ s across phases of structured stressor paradigms. Thus, the true timescale of vagal regulation-and the extent to which it can be observed during unprompted crying-is unknown. The current study utilized a recently validated method to calculate respiratory sinus arrhythmia (RSA) dynamically at a high resolution of 5 Hz (updated every 200 ms) in a home-based infant study. Using an event-related analysis, we calculated the relative change in RSA around the onset of naturally occurring unprompted instances of n = 41 infants' 180 crying events. As predicted, RSA significantly decreased after the onset of crying compared to non-crying chance changes in RSA. Decreasing trends in RSA were driven by infants with higher pre-cry RSA values, infants rated lower in Negative Affectivity, and those rated both high and low in Orienting by their mothers. Our results display the timescale of RSA in spontaneous and naturalistic episodes of infant crying and that these dynamic RSA patterns are aligned with real-time levels of RSA and also caregiver-reported temperament.


Assuntos
Choro , Arritmia Sinusal Respiratória , Feminino , Humanos , Lactente , Choro/fisiologia , Nervo Vago/fisiologia , Mães , Arritmia Sinusal Respiratória/fisiologia , Arritmia Sinusal
15.
Sensors (Basel) ; 23(20)2023 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-37896557

RESUMO

BACKGROUND: The hospital-at-home (HAH) model is a viable alternative for conventional in-hospital stays worldwide. Serum electrolyte abnormalities are common in acute patients, especially in those with many comorbidities. Pathologic changes in cardiac electrophysiology pose a potential risk during HAH stays. Periodical electrocardiogram (ECG) tracing is therefore advised, but few studies have evaluated the accuracy and efficiency of compact, self-activated ECG devices in HAH settings. This study aimed to evaluate the reliability of such a device in comparison with a standard 12-lead ECG. METHODS: We prospectively recruited consecutive patients admitted to the Sheba Beyond Virtual Hospital, in the HAH department, during a 3-month duration. Each patient underwent a 12-lead ECG recording using the legacy device and a consecutive recording by a compact six-lead device. Baseline patient characteristics during hospitalization were collected. The level of agreement between devices was measured by Cohen's kappa coefficient for inter-rater reliability (Ϗ). RESULTS: Fifty patients were included in the study (median age 80 years, IQR 14). In total, 26 (52%) had electrolyte disturbances. Abnormal D-dimer values were observed in 33 (66%) patients, and 12 (24%) patients had elevated troponin values. We found a level of 94.5% raw agreement between devices with regards to nine of the options included in the automatic read-out of the legacy device. The calculated Ϗ was 0.72, classified as a substantial consensus. The rate of raw consensus regarding the ECG intervals' measurement (PR, RR, and QT) was 78.5%, and the calculated Ϗ was 0.42, corresponding to a moderate level of agreement. CONCLUSION: This is the first report to our knowledge regarding the feasibility of using a compact, six-lead ECG device in the setting of an HAH to be safe and bearing satisfying agreement level with a legacy, 12-lead ECG device, enabling quick, accessible arrythmia detection in this setting. Our findings bear a promise to the future development of telemedicine-based hospital-at-home methodology.


Assuntos
Eletrocardiografia , Telemedicina , Humanos , Idoso de 80 Anos ou mais , Reprodutibilidade dos Testes , Eletrocardiografia/métodos , Telemedicina/métodos , Hospitais , Eletrólitos
16.
Z Gerontol Geriatr ; 56(2): 146-152, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35091801

RESUMO

BACKGROUND: Atrial fibrillation (AF) is the most frequent cardiac arrhythmia with an impact on morbidity and mortality found in the geriatric population. OBJECTIVE: This retrospective study is the first to investigate the prevalence, treatment and comorbidities of AF in a large cohort of older adults. MATERIAL AND METHODS: Older adults with AF hospitalized between 2010 and 2018. The mean age of the 10,700 AF patients in 2018 was 83.2 ± 6.4 years. The frequency of anticoagulation in older adults with AF between 2010 and 2018 was analyzed. The relationship between comorbidities and anticoagulation in 2018 was examined. Logistic regression analysis was used to identify possible predictive factors for anticoagulation. RESULTS: The prevalence of AF in 35,887 hospitalized older adults was 29.8% in 2018. The mean CHA2DS2VASc score was 4.4 ± 1.3 (male 3.8 ± 1.3, female 4.7 ± 1.2). From 2010 to 2018, the frequency of anticoagulation for patients with AF rose from 32.1% to 64.2%. Statistically significant differences in the examined characteristics between anticoagulated and not anticoagulated patients were found. Furthermore, there were no predictive factors for anticoagulation in multivariate logistic analysis. CONCLUSION: Hospitalized older adults have an increased prevalence of AF compared to the general population. Despite the higher risk of bleeding, older adults were more frequently anticoagulated in the observation period, preferably with direct oral anticoagulants (DOACs). Patients without anticoagulation had more diagnoses and were worse in functional tests. This study suggests that the decision to give anticoagulants to older adults should be personalized.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Prevalência , Estudos Retrospectivos , Fatores de Risco , Anticoagulantes/uso terapêutico
17.
J Cardiovasc Electrophysiol ; 33(7): 1405-1411, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35441420

RESUMO

INTRODUCTION: Areas displaying reduced bipolar voltage are defined as low-voltage areas (LVAs). Moreover, left atrial (LA) LVAs after pulmonary vein isolation (PVI) have been reported as a predictor of recurrent atrial fibrillation (AF). In this study, we compared grid mapping catheter (GMC) with PentaRay catheter (PC) for LA voltage mapping on Ensite Precision mapping system. METHODS: Twenty-six consecutive patients with LVAs and border zone within the LA were enrolled. After achieving PVI, voltage mapping under high right atrial pacing for 600 ms was performed twice using each catheter type (GMC first, PC next). Furthermore, LVA was defined as a region with a bipolar voltage of <0.50, and border zone was defined as a region with a bipolar voltage of <1.0, or <1.5 mV. RESULTS: Compared with PC, using GMC, voltage mapping contained more mapping points (20 242 [15 859, 26 013] vs. 5589 [4088, 7649]; p < .0001), and more mapping points per minute(1428 [1275, 1803] vs. 558 [372, 783]; p < .0001). In addition, LVA and border zone size using GMC was significantly less than that reported using PC: <1.0 mV (5.9 cm2 [2.9, 20.2] vs. 13.9 cm2 [6.3, 24.1], p = .018) and <1.5 mV voltage cutoff (10.6 cm2 [6.6, 27.2] vs. 21.6 cm2 [12.6, 35.0], p = .005). CONCLUSION: Bipolar voltage amplitude estimated by GMC was significantly larger than that estimated by PC on Ensite Precision mapping system. GMC may be able to find highly selective identification of LVAs with lower prevalence and smaller LVA and border zone size.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Potenciais de Ação , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Veias Pulmonares/cirurgia
18.
Europace ; 24(3): 362-374, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-34516616

RESUMO

Patients with cardiac implantable electronic devices (CIED) undergoing radiotherapy (RT) are more common due to the ageing of the population. With newer CIEDs' implementing the complementary metal-oxide semiconductor (CMOS) technology which allows the miniaturization of CIED, it is also more susceptible to RT. Effects of RT on CIED ranges from device interference, device operational/memory errors of permanent damage. These malfunctions can cause life-threatening clinical effects. Cumulative dose is not the only component of RT that causes CIED malfunction, as neutron use and dose rate effect also affects CIEDs. The management of this patient cohort in clinical practice is inconsistent due to the lack of a consistent guideline from manufacturers and physician specialty societies. Our review will focus on the current clinical practice and the recently updated guidelines of managing patients with CIED undergoing RT. We aim to simplify the evidence and provide a simple and easy to use guide based on the recent guidelines.


Assuntos
Desfibriladores Implantáveis , Neoplasias , Marca-Passo Artificial , Eletrônica , Humanos , Neoplasias/radioterapia , Radioterapia/efeitos adversos , Estudos Retrospectivos
19.
BMC Cardiovasc Disord ; 22(1): 252, 2022 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-35658897

RESUMO

BACKGROUND: Commotio cordis is an event in which a blunt, non-penetrating blow to the chest occurs, triggering a life-threatening arrhythmia and often sudden death. This phenomenon is often seen in young, male athletes and has become increasingly well-known over the past few decades. We present a unique case in which ventricular fibrillation occurs in an older male athlete after blunt trauma. CASE PRESENTATION: Patient with no known medical history was brought to the ER after being found unconscious after a soccer ball kick to the chest. He was found to be in ventricular fibrillation and successfully resuscitated on the soccer field. Patient was admitted to the hospital and lab workup and initial imaging were unremarkable, except elevated troponin and lactate, which returned to normal levels. An echocardiogram showed global left ventricular systolic dysfunction with a visually estimated ejection fraction of 45-50%. Coronary showed angiographically nonobstructive coronary arteries. The patient was diagnosed with commotio cordis and discharged from the hospital in stable condition. Follow-up echocardiogram continued to show low ejection fraction and event monitor demonstrated frequent polymorphic ventricular tachycardia with periods of asystole. CONCLUSION: This case is unique in that blunt trauma to the chest from a soccer ball immediately triggered ventricular fibrillation in a patient with a possible cardiomyopathy. It is possible that the blunt trauma caused primary commotio cordis that led to cardiomyopathy in a previous healthy man, or that an underlying cardiomyopathy made it more likely for this to occur. Overall, increased awareness and prevention efforts of blunt chest trauma are required to reduce the high mortality associated life-threatening arrhythmias. There is limited data regarding the interplay between these two entities.


Assuntos
Commotio Cordis , Traumatismos Torácicos , Ferimentos não Penetrantes , Adulto , Arritmias Cardíacas/complicações , Commotio Cordis/complicações , Commotio Cordis/etiologia , Morte Súbita Cardíaca/etiologia , Humanos , Masculino , Traumatismos Torácicos/complicações , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/terapia , Ferimentos não Penetrantes/complicações , Ferimentos não Penetrantes/diagnóstico por imagem
20.
Pacing Clin Electrophysiol ; 45(11): 1306-1309, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35579193

RESUMO

BACKGROUND: Complications using internal cardiac monitors (ICM) have been reported at a low rate. Targeted analyses of complications have not been well described in the literature. OBJECTIVE: To investigate and describe complications associated with ICM events reported to the FDA's Manufacturer and User Facility Device Experience (MAUDE) database. METHODS: Our team reviewed all reported events for the Reveal LINQ loop recorder submitted to the MAUDE database over 7 years (1/1/2013-12/31/2019). A 5% random selection of reports was audited by two researchers to ensure report validity. Two cardiologists manually reviewed death and incongruent events for final interpretation. RESULTS: 12,652 records were obtained during the observed time period. A total of 15,587 device complications were reported. Of this, undersensing (n = 4509, 28.93%), premature discharge of battery (n = 3262, 20.93%), oversensing (n = 2788, 17.89%), and other sensing issues (n = 1532, 9.83%) were most commonly reported. Patient adverse events were reported 1,030 times. Pain or discomfort (n = 275, 26.70%), site infection (n = 213, 20.68%), erosion (n = 138, 13.40%), and impaired healing (n = 49, 4.76%) were most commonly reported to affect patients. Death was reported four times; after expert review, no reports justified the device or procedure as a reasonable cause. CONCLUSION: Several non-life-threatening ICM complications were commonly noted from the analysis. This study supports the safe use of ICMs. A better understanding of the complication profile will help providers select patients, provide informed consent, and expected management.


Assuntos
Cardiopatias , Estados Unidos , Humanos , Bases de Dados Factuais , United States Food and Drug Administration