1.
J Am Chem Soc ; 135(30): 11125-30, 2013 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-23802735

RESUMO

For the development of a rechargeable metal-air battery, which is expected to become one of the most widely used batteries in the future, slow kinetics of discharging and charging reactions at the air electrode, i.e., oxygen reduction reaction (ORR) and oxygen evolution reaction (OER), respectively, are the most critical problems. Here we report that Ruddlesden-Popper-type layered perovskite, RP-LaSr3Fe3O10 (n = 3), functions as a reversible air electrode catalyst for both ORR and OER at an equilibrium potential of 1.23 V with almost no overpotentials. The function of RP-LaSr3Fe3O10 as an ORR catalyst was confirmed by using an alkaline fuel cell composed of Pd/LaSr3Fe3O10-2x(OH)2x·H2O/RP-LaSr3Fe3O10 as an open circuit voltage (OCV) of 1.23 V was obtained. RP-LaSr3Fe3O10 also catalyzed OER at an equilibrium potential of 1.23 V with almost no overpotentials. Reversible ORR and OER are achieved because of the easily removable oxygen present in RP-LaSr3Fe3O10. Thus, RP-LaSr3Fe3O10 minimizes efficiency losses caused by reactions during charging and discharging at the air electrode and can be considered to be the ORR/OER electrocatalyst for rechargeable metal-air batteries.

2.
Radiat Prot Dosimetry ; 184(3-4): 418-421, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31038709

RESUMO

Focusing on the scalability of Two-Filter Method, we started to develop a monitor for the concentration of radon and its progeny. In this study, we investigated the influence of a high-humidity environment on measuring radon concentration, and the influence of the decay chamber of the monitor on the measurement. In the high-humidity test, the conversion factor of (Bqm-3)/(cpm) tends to raise with increasing humidity. On the measurement of radon progeny, existence of the decay chamber of the monitor makes measurement sensitivity lower under environments of little aerosols. Radon concentration measurement by the developed monitor could be influenced by environmental humidity, and that counting loss could occur due to deposition of radon progeny inside of the decay chamber. Correction relating these would be needed based on the data of calibration tests.


Assuntos
Aerossóis/análise , Poluentes Radioativos do Ar/análise , Monitoramento de Radiação/métodos , Produtos de Decaimento de Radônio/análise , Radônio/análise
3.
Appl Radiat Isot ; 126: 79-82, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28111091

RESUMO

In the present study, a continuous radioactive aerosol measurement system (CRAMS) was developed for measurements of radioactive plume (e.g. 131I, 134Cs and 137Cs) under the emergency situation, and measurements of radon/thoron progeny under the existing situation. As a result, it is suggested that the CRAMS could follow the variation of radon concentration, and the detection limit of the CRAMS under ambient dose equivalent rate of 20µSvh-1, where the temporary evacuation is required within one week in the Japanese regulation, was evaluated to be 129Bqm-3 in the manner of ISO11929.