Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 152
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(6)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38544279

RESUMO

Respiratory rate (fR) monitoring through wearable devices is crucial in several scenarios, providing insights into well-being and sports performance while minimizing interference with daily activities. Strain sensors embedded into garments stand out but require thorough investigation for optimal deployment. Optimal sensor positioning is often overlooked, and when addressed, the quality of the respiratory signal is neglected. Additionally, sensor metrological characterization after sensor integration is often omitted. In this study, we present the design, development, and feasibility assessment of a smart t-shirt embedded with two flexible sensors for fR monitoring. Guided by a motion capture system, optimal sensor design and position on the chest wall were defined, considering both signal magnitude and quality. The sensors were developed, embedded into the wearable system, and metrologically characterized, demonstrating a remarkable response to both static (sensitivity 9.4 Ω⋅%-1 and 9.1 Ω⋅%-1 for sensor A and sensor B, respectively) and cyclic loads (min. hysteresis span 20.4% at 36 bpm obtained for sensor A). The feasibility of the wearable system was assessed on healthy volunteers both under static and dynamic conditions (such as running, walking, and climbing stairs). A mean absolute error of 0.32 bpm was obtained by averaging all subjects and tests using the combination of the two sensors. This value was lower than that obtained using both sensor A (0.53 bpm) and sensor B (0.78 bpm) individually. Our study highlights the importance of signal amplitude and quality in optimal sensor placement evaluation, as well as the characterization of the embedded sensors for metrological assessment.


Assuntos
Corrida , Dispositivos Eletrônicos Vestíveis , Humanos , Monitorização Fisiológica , Taxa Respiratória , Têxteis
2.
Sensors (Basel) ; 24(9)2024 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-38733040

RESUMO

Shoulder pain represents the most frequently reported musculoskeletal disorder, often leading to significant functional impairment and pain, impacting quality of life. Home-based rehabilitation programs offer a more accessible and convenient solution for an effective shoulder disorder treatment, addressing logistical and financial constraints associated with traditional physiotherapy. The aim of this systematic review is to report the monitoring devices currently proposed and tested for shoulder rehabilitation in home settings. The research question was formulated using the PICO approach, and the PRISMA guidelines were applied to ensure a transparent methodology for the systematic review process. A comprehensive search of PubMed and Scopus was conducted, and the results were included from 2014 up to 2023. Three different tools (i.e., the Rob 2 version of the Cochrane risk-of-bias tool, the Joanna Briggs Institute (JBI) Critical Appraisal tool, and the ROBINS-I tool) were used to assess the risk of bias. Fifteen studies were included as they fulfilled the inclusion criteria. The results showed that wearable systems represent a promising solution as remote monitoring technologies, offering quantitative and clinically meaningful insights into the progress of individuals within a rehabilitation pathway. Recent trends indicate a growing use of low-cost, non-intrusive visual tracking devices, such as camera-based monitoring systems, within the domain of tele-rehabilitation. The integration of home-based monitoring devices alongside traditional rehabilitation methods is acquiring significant attention, offering broader access to high-quality care, and potentially reducing healthcare costs associated with in-person therapy.


Assuntos
Dor de Ombro , Humanos , Dor de Ombro/reabilitação , Telerreabilitação/métodos , Dispositivos Eletrônicos Vestíveis , Qualidade de Vida , Ombro , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Serviços de Assistência Domiciliar , Modalidades de Fisioterapia/instrumentação
3.
Sensors (Basel) ; 24(2)2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38257715

RESUMO

Accurately mapping the temperature during ablation is crucial for improving clinical outcomes. While various sensor configurations have been suggested in the literature, depending on the sensors' type, number, and size, a comprehensive understanding of optimizing these parameters for precise temperature reconstruction is still lacking. This study addresses this gap by introducing a tool based on a theoretical model to optimize the placement of fiber Bragg grating sensors (FBG) within the organ undergoing ablation. The theoretical model serves as a general framework, allowing for adaptation to various situations. In practical application, the model provides a foundational structure, with the flexibility to tailor specific optimal solutions by adjusting problem-specific data. We propose a nonlinear and nonconvex (and, thus, only solvable in an approximated manner) optimization formulation to determine the optimal distribution and three-dimensional placement of FBG arrays. The optimization aims to find a trade-off among two objectives: maximizing the variance of the expected temperatures measured by the sensors, which can be obtained from a predictive simulation that considers both the type of applicator used and the specific organ involved, and maximizing the squared sum of the distances between the sensor pairs. The proposed approach provides a trade-off between collecting diverse temperatures and not having all the sensors concentrated in a single area. We address the optimization problem through the utilization of approximation schemes in programming. We then substantiate the efficacy of this approach through simulations. This study tackles optimizing the FBGs' sensor placement for precise temperature monitoring during tumor ablation. Optimizing the FBG placement enhances temperature mapping, aiding in tumor cell eradication while minimizing damage to surrounding tissues.

4.
Sensors (Basel) ; 24(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38475147

RESUMO

The safeguarding of plant health is vital for optimizing crop growth practices, especially in the face of the biggest challenges of our generation, namely the environmental crisis and the dramatic changes in the climate. Among the many innovative tools developed to address these issues, wearable sensors have recently been proposed for monitoring plant growth and microclimates in a sustainable manner. These systems are composed of flexible matrices with embedded sensing elements, showing promise in revolutionizing plant monitoring without being intrusive. Despite their potential benefits, concerns arise regarding the effects of the long-term coexistence of these devices with the plant surface. Surprisingly, a systematic analysis of their influence on plant physiology is lacking. This study aims to investigate the effect of the color and geometric features of flexible matrices on two key plant physiological functions: photosynthesis and transpiration. Our findings indicate that the negative effects associated with colored substrates, as identified in recent research, can be minimized by holing the matrix surface with a percentage of voids of 15.7%. This approach mitigates interference with light absorption and reduces water loss to a negligible extent, making our work one of the first pioneering efforts in understanding the intricate relationship between plant wearables' features and plant health.


Assuntos
Transpiração Vegetal , Dispositivos Eletrônicos Vestíveis , Transpiração Vegetal/fisiologia , Fotossíntese/fisiologia , Fenômenos Fisiológicos Vegetais , Transporte Biológico , Água , Folhas de Planta/fisiologia
5.
BMC Musculoskelet Disord ; 24(1): 766, 2023 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-37770871

RESUMO

PURPOSE: Radiofrequency ablation is an increasingly used surgical option for ablation, resection and coagulation of soft tissues in joint arthroscopy. One of the major issues of thermal ablation is the temperature monitoring across the target areas, as cellular mortality is a direct consequence of thermal dosimetry. Temperatures from 45 °C to 50 °C are at risk of damage to chondrocytes. One of the most reliable tools for temperature monitoring is represented by fiber optic sensors, as they allow accurate and real-time temperature measurement via a minimally invasive approach. The aim of this study was to determine, by fiber Bragg grating sensors (FBGs), the safety of radiofrequency ablation in tissue heating applied to ex-vivo bovine hip joints. METHODS: Ex vivo bovine hips were subjected to radiofrequency ablation, specifically in the acetabular labrum, for a total of two experiments. The WEREWOLF System (Smith + Nephew, Watford, UK) was employed in high operating mode and in a controlled ablation way. One optical fiber embedding seven FBGs was used to record multipoint temperature variations. Each sensor was 1 mm in length with a distance from edge to edge with each other of 2 mm. RESULTS: The maximum variation was recorded in both the tests by the FBG1 (i.e., the closest one to the electrode tip) and was lower than to 2.8 °C. The other sensors (from FBG2 to FBG7) did not record a significant temperature change throughout the duration of the experiment (maximum up to 0.7 °C for FBG7). CONCLUSIONS: No significant increase in temperature was observed at any of the seven sites. The sensor nearest to the radiofrequency source exhibited the highest temperature rise, but the variation was only 3 °C. The minimal temperature increase registered at the measurement sites, according to existing literature, is not expected to be cytotoxic. FBGs demonstrate the potential to fulfil the strict requirements for temperature measurements during arthroscopic surgery.


Assuntos
Articulação do Quadril , Ablação por Radiofrequência , Humanos , Bovinos , Animais , Temperatura , Artroscopia , Condrócitos
6.
BMC Musculoskelet Disord ; 24(1): 859, 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37919702

RESUMO

BACKGROUND: Virtual Reality (VR) systems have been increasingly used across several medical fields. A crucial preliminary step for developing optimized VR-based applications for rehabilitation purposes is identifying potential interventions to meet the requirements necessary to satisfy end-users' needs. This study aims to assess the acceptability, usability, and appropriateness of a VR physical therapy program executed with Oculus Quest 2 by expert physiotherapists of shoulder musculoskeletal rehabilitation. METHODS: Eleven physiotherapists were enrolled to test a VR program for shoulder musculoskeletal rehabilitation. At the end of each session, physiotherapists completed three questionnaires about the acceptability, usability, and appropriateness of the VR system and application, investigating aspects such as wearability, safety, stability, ease of control, comfort, size, utility, playability, and use mode. RESULTS: The acceptability questionnaire revealed that all the physiotherapists found the VR system easy to wear and control, very confident, and safe. The usability questionnaire showed that most physiotherapists (73%) found the VR application entertaining, although only 45% said the system could be used independently by patients without the support of a therapist. Many physiotherapists found the use of the VR application appropriate for patients with rotator cuff tears treated conservatively (63.6%) or surgically (54.5%), for patients with shoulder osteoarthritis treated conservatively (72.7%), for patients with shoulder osteoarthritis after surgical treatment (63.6%). 91% of physiotherapists think it would be best for patients to use the VR system under the supervision of a therapist and not independently in a home setting. CONCLUSIONS: The use of VR in orthopaedic rehabilitation is encouraging, although further efforts are needed to increase the independent use of patients without the supervision of a physiotherapist. Moreover, future studies should strive to ensure the clinical effectiveness of VR rehabilitation in reaching therapeutic goal settings.


Assuntos
Osteoartrite , Realidade Virtual , Humanos , Ombro , Extremidade Superior , Modalidades de Fisioterapia
7.
Sensors (Basel) ; 23(15)2023 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-37571742

RESUMO

The identification of respiratory patterns based on the movement of the chest wall can assist in monitoring an individual's health status, particularly those with neuromuscular disorders, such as hemiplegia and Duchenne muscular dystrophy. Thoraco-abdominal asynchrony (TAA) refers to the lack of coordination between the rib cage and abdominal movements, characterized by a time delay in their expansion. Motion capture systems, like optoelectronic plethysmography (OEP), are commonly employed to assess these asynchronous movements. However, alternative technologies able to capture chest wall movements without physical contact, such as RGB digital cameras and time-of-flight digital cameras, can also be utilized due to their accessibility, affordability, and non-invasive nature. This study explores the possibility of using a single RGB digital camera to record the kinematics of the thoracic and abdominal regions by placing four non-reflective markers on the torso. In order to choose the positions of these markers, we previously investigated the movements of 89 chest wall landmarks using OEP. Laboratory tests and volunteer experiments were conducted to assess the viability of the proposed system in capturing the kinematics of the chest wall and estimating various time-related respiratory parameters (i.e., fR, Ti, Te, and Ttot) as well as TAA indexes. The results demonstrate a high level of agreement between the detected chest wall kinematics and the reference data. Furthermore, the system shows promising potential in estimating time-related respiratory parameters and identifying phase shifts indicative of TAA, thus suggesting its feasibility in detecting abnormal chest wall movements without physical contact with a single RGB camera.


Assuntos
Parede Torácica , Humanos , Estudos de Viabilidade , Fenômenos Biomecânicos , Mecânica Respiratória , Respiração , Pletismografia/métodos
8.
Sensors (Basel) ; 23(15)2023 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-37571723

RESUMO

Monitoring shoulder kinematics, including the scapular segment, is of great relevance in the orthopaedic field. Among wearable systems, magneto-inertial measurement units (M-IMUs) represent a valid alternative for applications in unstructured environments. The aim of this systematic literature review is to report and describe the existing methods to estimate 3D scapular movements through wearable systems integrating M-IMUs. A comprehensive search of PubMed, IEEE Xplore, and Web of Science was performed, and results were included up to May 2023. A total of 14 articles was included. The results showed high heterogeneity among studies regarding calibration procedures, tasks executed, and the population. Two different techniques were described, i.e., with the x-axis aligned with the cranial edge of the scapular spine or positioned on the flat surface of the acromion with the x-axis perpendicular to the scapular spine. Sensor placement affected the scapular motion and, also, the kinematic output. Further studies should be conducted to establish a universal protocol that reduces the variability among studies. Establishing a protocol that can be carried out without difficulty or pain by patients with shoulder musculoskeletal disorders could be of great clinical relevance for patients and clinicians to monitor 3D scapular kinematics in unstructured settings or during common clinical practice.


Assuntos
Articulação do Ombro , Dispositivos Eletrônicos Vestíveis , Humanos , Fenômenos Biomecânicos , Escápula , Ombro , Amplitude de Movimento Articular
9.
Sensors (Basel) ; 23(24)2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38139623

RESUMO

Nowadays, there is an ever-growing interest in assessing the collective intelligence (CI) of a team in a wide range of scenarios, thanks to its potential in enhancing teamwork and group performance. Recently, special attention has been devoted on the clinical setting, where breakdowns in teamwork, leadership, and communication can lead to adverse events, compromising patient safety. So far, researchers have mostly relied on surveys to study human behavior and group dynamics; however, this method is ineffective. In contrast, a promising solution to monitor behavioral and individual features that are reflective of CI is represented by wearable technologies. To date, the field of CI assessment still appears unstructured; therefore, the aim of this narrative review is to provide a detailed overview of the main group and individual parameters that can be monitored to evaluate CI in clinical settings, together with the wearables either already used to assess them or that have the potential to be applied in this scenario. The working principles, advantages, and disadvantages of each device are introduced in order to try to bring order in this field and provide a guide for future CI investigations in medical contexts.


Assuntos
Comunicação , Liderança , Humanos , Segurança do Paciente , Inteligência
10.
Sensors (Basel) ; 23(1)2023 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-36617147

RESUMO

Wearable devices are widely spreading in various scenarios for monitoring different parameters related to human and recently plant health. In the context of precision agriculture, wearables have proven to be a valuable alternative to traditional measurement methods for quantitatively monitoring plant development. This study proposed a multi-sensor wearable platform for monitoring the growth of plant organs (i.e., stem and fruit) and microclimate (i.e., environmental temperature-T and relative humidity-RH). The platform consists of a custom flexible strain sensor for monitoring growth when mounted on a plant and a commercial sensing unit for monitoring T and RH values of the plant surrounding. A different shape was conferred to the strain sensor according to the plant organs to be engineered. A dumbbell shape was chosen for the stem while a ring shape for the fruit. A metrological characterization was carried out to investigate the strain sensitivity of the proposed flexible sensors and then preliminary tests were performed in both indoor and outdoor scenarios to assess the platform performance. The promising results suggest that the proposed system can be considered one of the first attempts to design wearable and portable systems tailored to the specific plant organ with the potential to be used for future applications in the coming era of digital farms and precision agriculture.


Assuntos
Microclima , Dispositivos Eletrônicos Vestíveis , Humanos , Temperatura , Monitorização Fisiológica/métodos
11.
Sensors (Basel) ; 23(3)2023 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-36772656

RESUMO

Heart rate variability (HRV) indexes are becoming useful in various applications, from better diagnosis and prevention of diseases to predicting stress levels. Typically, HRV indexes are retrieved from the heart's electrical activity collected with an electrocardiographic signal (ECG). Heart-induced mechanical signals recorded from the body's surface can be utilized to record the mechanical activity of the heart and, in turn, extract HRV indexes from interbeat intervals (IBIs). Among others, accelerometers and gyroscopes can be used to register IBIs from precordial accelerations and chest wall angular velocities. However, unlike electrical signals, the morphology of mechanical ones is strongly affected by body posture. In this paper, we investigated the feasibility of estimating the most common linear and non-linear HRV indexes from accelerometer and gyroscope data collected with a wearable skin-interfaced Inertial Measurement Unit (IMU) positioned at the xiphoid level. Data were collected from 21 healthy volunteers assuming two common postures (i.e., seated and lying). Results show that using the gyroscope signal in the lying posture allows accurate results in estimating IBIs, thus allowing extracting of linear and non-linear HRV parameters that are not statistically significantly different from those extracted from reference ECG.


Assuntos
Coração , Parede Torácica , Humanos , Frequência Cardíaca/fisiologia , Eletrocardiografia , Postura
12.
Sensors (Basel) ; 22(7)2022 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-35408151

RESUMO

Heart rate (HR) and respiratory rate (fR) can be estimated by processing videos framing the upper body and face regions without any physical contact with the subject. This paper proposed a technique for continuously monitoring HR and fR via a multi-ROI approach based on the spectral analysis of RGB video frames recorded with a mobile device (i.e., a smartphone's camera). The respiratory signal was estimated by the motion of the chest, whereas the cardiac signal was retrieved from the pulsatile activity at the level of right and left cheeks and forehead. Videos were recorded from 18 healthy volunteers in four sessions with different user-camera distances (i.e., 0.5 m and 1.0 m) and illumination conditions (i.e., natural and artificial light). For HR estimation, three approaches were investigated based on single or multi-ROI approaches. A commercially available multiparametric device was used to record reference respiratory signals and electrocardiogram (ECG). The results demonstrated that the multi-ROI approach outperforms the single-ROI approach providing temporal trends of both the vital parameters comparable to those provided by the reference, with a mean absolute error (MAE) consistently below 1 breaths·min-1 for fR in all the scenarios, and a MAE between 0.7 bpm and 6 bpm for HR estimation, whose values increase at higher distances.


Assuntos
Eletrocardiografia , Taxa Respiratória , Computadores de Mão , Frequência Cardíaca , Humanos , Monitorização Fisiológica , Taxa Respiratória/fisiologia , Processamento de Sinais Assistido por Computador
13.
Sensors (Basel) ; 22(10)2022 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-35632361

RESUMO

In recent years, soft and flexible strain sensors have found application in wearable devices for monitoring human motion and physiological parameters. Conductive textile-based sensors are good candidates for developing these sensors. However, their robust electro-mechanical connection and susceptibility to environmental factors are still an open challenge to date. In this work, the manufacturing process of a silicone-textile composite resistive strain sensor based on a conductive resistive textile encapsulated into a dual-layer of silicone rubber is reported. In the working range typical of biomedical applications (up to 50%), the proposed flexible, skin-safe and moisture resistant strain sensor exhibited high sensitivity (gauge factor of -1.1), low hysteresis (maximum hysteresis error 3.2%) and ease of shaping in custom designs through a facile manufacturing process. To test the developed flexible sensor, two applicative scenarios covering the whole working range have been considered: the recording of the chest wall expansion during respiratory activity and the capture of the elbow flexion/extension movements.


Assuntos
Têxteis , Dispositivos Eletrônicos Vestíveis , Condutividade Elétrica , Humanos , Movimento (Física) , Elastômeros de Silicone
14.
Sensors (Basel) ; 22(6)2022 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-35336520

RESUMO

Music is an invaluable tool to improve affective valence during exercise, with the potential contribution of a mechanism called rhythmic entrainment. However, several methodological limitations impair our current understanding of the effect of music on relevant psychophysiological responses to exercise, including breathing variables. This study presents conceptual, methodological, and operational insight favoring the investigation of the effect of music on breathing during exercise. Three tools were developed for the quantification of the presence, degree, and magnitude of music-locomotor, locomotor-breathing, and music-breathing entrainment. The occurrence of entrainment was assessed during 30 min of moderate cycling exercise performed either when listening to music or not, and was complemented by the recording of relevant psychophysiological and mechanical variables. Respiratory frequency and expiratory time were among the physiological variables that were affected to a greater extent by music during exercise, and a significant (p < 0.05) music-breathing entrainment was found in all 12 participants. These findings suggest the importance of evaluating the effect of music on breathing responses to exercise, with potential implications for exercise prescription and adherence, and for the development of wearable devices simultaneously measuring music, locomotor, and breathing signals.


Assuntos
Música , Percepção Auditiva , Exercício Físico/fisiologia , Terapia por Exercício , Humanos , Música/psicologia , Respiração
15.
Sensors (Basel) ; 22(15)2022 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-35957358

RESUMO

Recently, the ever-growing interest in the continuous monitoring of heart function in out-of-laboratory settings for an early diagnosis of cardiovascular diseases has led to the investigation of innovative methods for cardiac monitoring. Among others, wearables recording seismic waves induced on the chest surface by the mechanical activity of the heart are becoming popular. For what concerns wearable-based methods, cardiac vibrations can be recorded from the thorax in the form of acceleration, angular velocity, and/or displacement by means of accelerometers, gyroscopes, and fiber optic sensors, respectively. The present paper reviews the currently available wearables for measuring precordial vibrations. The focus is on sensor technology and signal processing techniques for the extraction of the parameters of interest. Lastly, the explored application scenarios and experimental protocols with the relative influencing factors are discussed for each technique. The goal is to delve into these three fundamental aspects (i.e., wearable system, signal processing, and application scenario), which are mutually interrelated, to give a holistic view of the whole process, beyond the sensor aspect alone. The reader can gain a more complete picture of this context without disregarding any of these 3 aspects.


Assuntos
Vibração , Dispositivos Eletrônicos Vestíveis , Coração , Monitorização Fisiológica , Processamento de Sinais Assistido por Computador
16.
Sensors (Basel) ; 22(15)2022 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-35898015

RESUMO

Virtual reality (VR) systems are becoming increasingly attractive as joint kinematics monitoring systems during rehabilitation. This study aimed to evaluate the accuracy of the Oculus Quest 2 in measuring translational and rotational displacements. As the Oculus Quest 2 was chosen for future applications in shoulder rehabilitation, the translation range (minimum: ~200 mm, maximum: ~700 mm) corresponded to the forearm length of the 5th percentile female and the upper limb length of the 95th percentile male. The controller was moved on two structures designed to allow different translational displacements and rotations in the range 0-180°, to cover the range of motion of the upper limb. The controller measures were compared with those of a Qualisys optical capture system. The results showed a mean absolute error of 13.52 ± 6.57 mm at a distance of 500 mm from the head-mounted display along the x-direction. The maximum mean absolute error for rotational displacements was found to be 1.11 ± 0.37° for a rotation of 40° around the z-axis. Oculus Quest 2 is a promising VR tool for monitoring shoulder kinematics during rehabilitation. The inside-out movement tracking makes Oculus Quest 2 a viable alternative to traditional motion analysis systems.


Assuntos
Ombro , Realidade Virtual , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Movimento , Extremidade Superior
17.
Sensors (Basel) ; 22(4)2022 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-35214287

RESUMO

In this study, a novel wearable system for the identification of compensatory trunk movements (CTMs) in post-stroke hemiplegic patients is presented. The device is composed of seven soft sensing elements (SSEs) based on fiber Bragg grating (FBG) technology. Each SSE consists of a single FBG encapsulated into a flexible matrix to enhance the sensor's robustness and improve its compliance with the human body. The FBG's small size, light weight, multiplexing capability, and biocompatibility make the proposed wearable system suitable for multi-point measurements without any movement restriction. Firstly, its manufacturing process is presented, together with the SSEs' mechanical characterization to strain. Results of the metrological characterization showed a linear response of each SSE in the operating range. Then, the feasibility assessment of the proposed system is described. In particular, the device's capability of detecting CTMs was assessed on 10 healthy volunteers and eight hemiplegic patients while performing three tasks which are representative of typical everyday life actions. The wearable system showed good potential in detecting CTMs. This promising result may foster the use of the proposed device on post-stroke patients, aiming at assessing the proper course of the rehabilitation process both in clinical and domestic settings. Moreover, its use may aid in defining tailored strategies to improve post-stoke patients' motor recovery and quality of life.


Assuntos
Qualidade de Vida , Dispositivos Eletrônicos Vestíveis , Hemiplegia , Humanos , Movimento/fisiologia , Tronco/fisiologia
18.
Sensors (Basel) ; 22(17)2022 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-36081165

RESUMO

Quantitatively assessing personal health status is gaining increasing attention due to the improvement of diagnostic technology and the increasing occurrence of chronic pathologies. Monitoring physiological parameters allows for retrieving a general overview of the personal health status. Respiratory activity can provide relevant information, especially when pathologies affect the muscles and organs involved in breathing. Among many technologies, wearables may represent a valid solution for continuous and remote monitoring of respiratory activity, thus reducing healthcare costs. The most popular wearables used in this arena are based on detecting the breathing-induced movement of the chest wall. Therefore, their use in patients with impaired chest wall motion and abnormal respiratory kinematics can be challenging, but literature is still in its infancy. This study investigates the performance of a custom wearable device for respiratory monitoring in post-stroke patients. We tested the device on six hemiplegic patients under different respiratory regimes. The estimated respiratory parameters (i.e., respiratory frequency and the timing of the respiratory phase) demonstrated good agreement with the ones provided by a gold standard device. The promising results of this pilot study encourage the exploitation of wearables on these patients that may strongly impact the treatment of chronic diseases, such as hemiplegia.


Assuntos
Acidente Vascular Cerebral , Dispositivos Eletrônicos Vestíveis , Hemiplegia , Humanos , Projetos Piloto , Taxa Respiratória
19.
Sensors (Basel) ; 23(1)2022 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-36616959

RESUMO

Global climate change and exponential population growth pose a challenge to agricultural outputs. In this scenario, novel techniques have been proposed to improve plant growth and increase crop yields. Wearable sensors are emerging as promising tools for the non-invasive monitoring of plant physiological and microclimate parameters. Features of plant wearables, such as easy anchorage to different organs, compliance with natural surfaces, high flexibility, and biocompatibility, allow for the detection of growth without impacting the plant functions. This work proposed two wearable sensors based on fiber Bragg gratings (FBGs) within silicone matrices. The use of FBGs is motivated by their high sensitivity, multiplexing capacities, and chemical inertia. Firstly, we focused on the design and the fabrication of two plant wearables with different matrix shapes tailored to specific plant organs (i.e., tobacco stem and melon fruit). Then, we described the sensors' metrological properties to investigate the sensitivity to strain and the influence of environmental factors, such as temperature and humidity, on the sensors' performance. Finally, we performed experimental tests to preliminary assess the capability of the proposed sensors to monitor dimensional changes of plants in both laboratory and open field settings. The promising results will foster key actions to improve the use of this innovative technology in smart agriculture applications for increasing crop products quality, agricultural efficiency, and profits.


Assuntos
Tecnologia de Fibra Óptica , Dispositivos Eletrônicos Vestíveis , Estudos de Viabilidade , Desenvolvimento Vegetal , Agricultura
20.
Int J Hyperthermia ; 38(1): 1099-1110, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34315306

RESUMO

BACKGROUND: Photothermal therapy is currently under the spotlight to improve the efficacy of minimally invasive thermal treatment of solid tumors. The interplay of several factors including the radiation wavelengths and the nanoparticle characteristics underlie the thermal outcome. However, a quantitative thermal analysis in in vivo models embedding nanoparticles and under different near-infrared (NIR) wavelengths is missing. PURPOSE: We evaluate the thermal effects induced by different combinations of NIR laser wavelengths and gold nanorods (GNRs) in breast cancer tumor models in mice. MATERIALS AND METHODS: Four laser wavelengths within the therapeutic window, i.e., 808, 940, 975, and 1064 nm were employed, and corresponding GNRs were intratumorally injected. The tissue thermal response was evaluated in terms of temperature profile and time constants, considering the step response of a first-order system as a model. RESULTS: The 808 nm and 1064 nm lasers experienced the highest temperature enhancements (>24%) in presence of GNRs compared to controls; conversely, 975 nm and 940 nm lasers showed high temperatures in controls due to significant tissue absorption and the lowest temperature difference with and without GNRs (temperature enhancement <10%). The presence of GNRs resulted in small time constants, thus quicker laser-induced thermal response (from 67 s to 33 s at 808 nm). CONCLUSIONS: The thermal responses of different GNR-laser wavelength combinations quantitatively validate the widespread usage of 808 nm laser for nanoparticle-assisted photothermal procedures. Moreover, our results provide insights on other usable wavelengths, toward the identification of an effective photothermal treatment strategy for the removal of focal malignancies.


Assuntos
Neoplasias da Mama , Hipertermia Induzida , Nanotubos , Animais , Neoplasias da Mama/radioterapia , Feminino , Ouro/uso terapêutico , Humanos , Lasers , Camundongos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA