1.
Cytogenet Genome Res ; 163(3-4): 163-177, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37071978

RESUMO

In the case of a radiological or nuclear event, biological dosimetry can be an important tool to support clinical decision-making. During a nuclear event, individuals might be exposed to a mixed field of neutrons and photons. The composition of the field and the neutron energy spectrum influence the degree of damage to the chromosomes. During the transatlantic BALANCE project, an exposure similar to a Hiroshima-like device at a distance of 1.5 km from the epicenter was simulated, and biological dosimetry based on dicentric chromosomes was performed to evaluate the participants ability to discover unknown doses and to test the influence of differences in neutron spectra. In a first step, calibration curves were established by irradiating blood samples with 5 doses in the range of 0-4 Gy at two different facilities in Germany (Physikalisch-Technische Bundesanstalt [PTB]) and the USA (the Columbia IND Neutron Facility [CINF]). The samples were sent to eight participating laboratories from the RENEB network and dicentric chromosomes were scored by each participant. Next, blood samples were irradiated with 4 blind doses in each of the two facilities and sent to the participants to provide dose estimates based on the established calibration curves. Manual and semiautomatic scoring of dicentric chromosomes were evaluated for their applicability to neutron exposures. Moreover, the biological effectiveness of the neutrons from the two irradiation facilities was compared. The calibration curves from samples irradiated at CINF showed a 1.4 times higher biological effectiveness compared to samples irradiated at PTB. For manual scoring of dicentric chromosomes, the doses of the test samples were mostly successfully resolved based on the calibration curves established during the project. For semiautomatic scoring, the dose estimation for the test samples was less successful. Doses >2 Gy in the calibration curves revealed nonlinear associations between dose and dispersion index of the dicentric counts, especially for manual scoring. The differences in the biological effectiveness between the irradiation facilities suggested that the neutron energy spectrum can have a strong impact on the dicentric counts.


Assuntos
Nêutrons , Humanos , Alemanha
2.
Int J Radiat Biol ; 97(9): 1181-1198, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34138666

RESUMO

PURPOSE: Biological and/or physical assays for retrospective dosimetry are valuable tools to recover the exposure situation and to aid medical decision making. To further validate and improve such biological and physical assays, in 2019, EURADOS Working Group 10 and RENEB performed a field exercise in Lund, Sweden, to simulate various real-life exposure scenarios. MATERIALS AND METHODS: For the dicentric chromosome assay (DCA), blood tubes were located at anthropomorphic phantoms positioned in different geometries and were irradiated with a 1.36 TBq 192Ir-source. For each exposure condition, dose estimates were provided by at least one laboratory and for four conditions by 17 participating RENEB laboratories. Three radio-photoluminescence glass dosimeters were placed at each tube to assess reference doses. RESULTS: The DCA results were homogeneous between participants and matched well with the reference doses (≥95% of estimates within ±0.5 Gy of the reference). For samples close to the source systematic underestimation could be corrected by accounting for exposure time. Heterogeneity within and between tubes was detected for reference doses as well as for DCA doses estimates. CONCLUSIONS: The participants were able to successfully estimate the doses and to provide important information on the exposure scenarios under conditions closely resembling a real-life situation.


Assuntos
Cromossomos Humanos/genética , Cromossomos Humanos/efeitos da radiação , Radiometria , Aberrações Cromossômicas/efeitos da radiação , Humanos , Exposição à Radiação/análise , Estudos Retrospectivos
3.
Int J Radiat Biol ; 93(1): 99-109, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27437830

RESUMO

PURPOSE: RENEB, 'Realising the European Network of Biodosimetry and Physical Retrospective Dosimetry,' is a network for research and emergency response mutual assistance in biodosimetry within the EU. Within this extremely active network, a number of new dosimetry methods have recently been proposed or developed. There is a requirement to test and/or validate these candidate techniques and inter-comparison exercises are a well-established method for such validation. MATERIALS AND METHODS: The authors present details of inter-comparisons of four such new methods: dicentric chromosome analysis including telomere and centromere staining; the gene expression assay carried out in whole blood; Raman spectroscopy on blood lymphocytes, and detection of radiation-induced thermoluminescent signals in glass screens taken from mobile phones. RESULTS: In general the results show good agreement between the laboratories and methods within the expected levels of uncertainty, and thus demonstrate that there is a lot of potential for each of the candidate techniques. CONCLUSIONS: Further work is required before the new methods can be included within the suite of reliable dosimetry methods for use by RENEB partners and others in routine and emergency response scenarios.


Assuntos
Bioensaio/métodos , Planejamento em Desastres/métodos , Laboratórios , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Gestão da Segurança/métodos , União Europeia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Integração de Sistemas
4.
Int J Radiat Biol ; 93(1): 75-80, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27559844

RESUMO

PURPOSE: The RENEB accident exercise was carried out in order to train the RENEB participants in coordinating and managing potentially large data sets that would be generated in case of a major radiological event. MATERIALS AND METHODS: Each participant was offered the possibility to activate the network by sending an alerting email about a simulated radiation emergency. The same participant had to collect, compile and report capacity, triage categorization and exposure scenario results obtained from all other participants. The exercise was performed over 27 weeks and involved the network consisting of 28 institutes: 21 RENEB members, four candidates and three non-RENEB partners. RESULTS: The duration of a single exercise never exceeded 10 days, while the response from the assisting laboratories never came later than within half a day. During each week of the exercise, around 4500 samples were reported by all service laboratories (SL) to be examined and 54 scenarios were coherently estimated by all laboratories (the standard deviation from the mean of all SL answers for a given scenario category and a set of data was not larger than 3 patient codes). CONCLUSIONS: Each participant received training in both the role of a reference laboratory (activating the network) and of a service laboratory (responding to an activation request). The procedures in the case of radiological event were successfully established and tested.


Assuntos
Planejamento em Desastres/organização & administração , Monitoramento de Radiação/métodos , Liberação Nociva de Radioativos , Radiobiologia/educação , Gestão da Segurança/organização & administração , Triagem/organização & administração , Europa (Continente)
5.
Int J Radiat Biol ; 93(1): 36-47, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27673504

RESUMO

PURPOSE: In the framework of the 'Realizing the European Network of Biodosimetry' (RENEB) project, two intercomparison exercises were conducted to assess the suitability of an optimized version of the cytokinesis-block micronucleus assay, and to evaluate the capacity of a large laboratory network performing biodosimetry for radiation emergency triages. Twelve European institutions participated in the first exercise, and four non-RENEB labs were added in the second one. MATERIALS AND METHODS: Irradiated blood samples were shipped to participating labs, whose task was to culture these samples and provide a blind dose estimate. Micronucleus analysis was performed by automated, semi-automated and manual procedures. RESULTS: The dose estimates provided by network laboratories were in good agreement with true administered doses. The most accurate estimates were reported for low dose points (≤ 0.94 Gy). For higher dose points (≥ 2.7 Gy) a larger variation in estimates was observed, though in the second exercise the number of acceptable estimates increased satisfactorily. Higher accuracy was achieved with the semi-automated method. CONCLUSION: The results of the two exercises performed by our network demonstrate that the micronucleus assay is a useful tool for large-scale radiation emergencies, and can be successfully implemented within a large network of laboratories.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas/efeitos da radiação , Testes para Micronúcleos/métodos , Garantia da Qualidade dos Cuidados de Saúde , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Bioensaio/normas , Europa (Continente) , Humanos , Linfócitos/efeitos da radiação , Monitoramento de Radiação/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Int J Radiat Biol ; 93(1): 58-64, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27686523

RESUMO

PURPOSE: Within the EU RENEB project, seven laboratories have taken part in training and harmonisation activities to strengthen triage gamma-H2AX-based radiation exposure assessment. This has culminated in a second triage biodosimetry exercise. MATERIALS AND METHODS: Whole blood and separated lymphocyte samples were homogenously irradiated with 60Co gamma rays at 0.5, 2.5 (blind samples), 0 and 2 Gy (reference samples). Following post-exposure incubations of 4 and 24 h, 16 samples were shipped on ice packs to each partner. The samples were stained and scored for gamma-H2AX foci, using manual and/or automated fluorescence microscope scoring strategies. Dose estimates were obtained and used to assign triage categories to the samples. RESULTS: Average dose estimates across all the laboratories correlated well with true doses. The most accurate assignment of triage category was achieved by manual scoring of the 4-h blood and lymphocyte samples. Only three samples out of a total of 46 were miscategorized in a way that could have adversely effected the clinical management of a radiation casualty. CONCLUSIONS: This inter-comparison exercise has demonstrated that following a recent acute radiation exposure, the gamma-H2AX assay could be a useful triage tool that can be successfully applied across a network of laboratories.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas/efeitos da radiação , Dano ao DNA/genética , Raios gama , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Bioensaio/normas , Europa (Continente) , Histonas/genética , Humanos , Linfócitos/fisiologia , Linfócitos/efeitos da radiação , Garantia da Qualidade dos Cuidados de Saúde , Monitoramento de Radiação/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Int J Radiat Biol ; 93(1): 30-35, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27705052

RESUMO

PURPOSE: In the framework of RENEB, several biodosimetry exercises were conducted analyzing different endpoints. Among them, the analysis of translocations is considered the most useful method for retrospective biodosimetry due to the relative stability of their frequency with post irradiation time. The aim of this study was to harmonize the accuracy of translocation-based biodosimetry within the RENEB consortium. MATERIALS AND METHODS: An initial telescoring exercise analyzing FISH metaphase images was done to harmonize chromosome aberration descriptions. Then two blind intercomparison exercises (IE) were performed, by sending irradiated blood samples to each partner. Samples were cultured and stained by each partner using their standard protocol and translocation frequency was used to produce dose estimates. RESULTS: The coefficient of variation in the 1st IE (CV = 0.34) was higher than in the 2nd IE (CV = 0.16 and 0.23 in the two samples analyzed), for the genomic frequency of total translocations. Z-score analysis revealed that eight out of 10 and 17 out of 20 dose estimates were satisfactory in the 1st and 2nd IE, respectively. CONCLUSIONS: The results obtained indicate that, despite the problems identified in few partners, which can be corrected, the RENEB consortium is able to carry out retrospective biodosimetry analyzing the frequency of translocations by FISH.


Assuntos
Bioensaio/métodos , Hibridização in Situ Fluorescente/métodos , Garantia da Qualidade dos Cuidados de Saúde , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Translocação Genética/efeitos da radiação , Bioensaio/normas , Europa (Continente) , Humanos , Hibridização in Situ Fluorescente/normas , Linfócitos/efeitos da radiação , Monitoramento de Radiação/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Translocação Genética/genética
8.
Int J Radiat Biol ; 93(1): 2-14, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27707245

RESUMO

PURPOSE: A European network was initiated in 2012 by 23 partners from 16 European countries with the aim to significantly increase individualized dose reconstruction in case of large-scale radiological emergency scenarios. RESULTS: The network was built on three complementary pillars: (1) an operational basis with seven biological and physical dosimetric assays in ready-to-use mode, (2) a basis for education, training and quality assurance, and (3) a basis for further network development regarding new techniques and members. Techniques for individual dose estimation based on biological samples and/or inert personalized devices as mobile phones or smart phones were optimized to support rapid categorization of many potential victims according to the received dose to the blood or personal devices. Communication and cross-border collaboration were also standardized. To assure long-term sustainability of the network, cooperation with national and international emergency preparedness organizations was initiated and links to radiation protection and research platforms have been developed. A legal framework, based on a Memorandum of Understanding, was established and signed by 27 organizations by the end of 2015. CONCLUSIONS: RENEB is a European Network of biological and physical-retrospective dosimetry, with the capacity and capability to perform large-scale rapid individualized dose estimation. Specialized to handle large numbers of samples, RENEB is able to contribute to radiological emergency preparedness and wider large-scale research projects.


Assuntos
Bioensaio/métodos , Planejamento em Desastres/organização & administração , Lesões por Radiação/prevenção & controle , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Gestão da Segurança/organização & administração , Emergências , Europa (Continente) , Humanos , Objetivos Organizacionais , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Liberação Nociva de Radioativos/prevenção & controle
9.
Int J Radiat Biol ; 93(1): 20-29, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27766931

RESUMO

PURPOSE: Two quality controlled inter-laboratory exercises were organized within the EU project 'Realizing the European Network of Biodosimetry (RENEB)' to further optimize the dicentric chromosome assay (DCA) and to identify needs for training and harmonization activities within the RENEB network. MATERIALS AND METHODS: The general study design included blood shipment, sample processing, analysis of chromosome aberrations and radiation dose assessment. After manual scoring of dicentric chromosomes in different cell numbers dose estimations and corresponding 95% confidence intervals were submitted by the participants. RESULTS: The shipment of blood samples to the partners in the European Community (EU) were performed successfully. Outside the EU unacceptable delays occurred. The results of the dose estimation demonstrate a very successful classification of the blood samples in medically relevant groups. In comparison to the 1st exercise the 2nd intercomparison showed an improvement in the accuracy of dose estimations especially for the high dose point. CONCLUSIONS: In case of a large-scale radiological incident, the pooling of ressources by networks can enhance the rapid classification of individuals in medically relevant treatment groups based on the DCA. The performance of the RENEB network as a whole has clearly benefited from harmonization processes and specific training activities for the network partners.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas/efeitos da radiação , Testes para Micronúcleos/métodos , Garantia da Qualidade dos Cuidados de Saúde , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Bioensaio/normas , Europa (Continente) , Humanos , Linfócitos/efeitos da radiação , Monitoramento de Radiação/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade