1.
Radiat Environ Biophys ; 59(3): 357-387, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32372284

RESUMEN

This work presents an overview of the applications of retrospective dosimetry techniques in case of incorporation of radionuclides. The fact that internal exposures are characterized by a spatially inhomogeneous irradiation of the body, which is potentially prolonged over large periods and variable over time, is particularly problematic for biological and electron paramagnetic resonance (EPR) dosimetry methods when compared with external exposures. The paper gives initially specific information about internal dosimetry methods, the most common cytogenetic techniques used in biological dosimetry and EPR dosimetry applied to tooth enamel. Based on real-case scenarios, dose estimates obtained from bioassay data as well as with biological and/or EPR dosimetry are compared and critically discussed. In most of the scenarios presented, concomitant external exposures were responsible for the greater portion of the received dose. As no assay is available which can discriminate between radiation of different types and different LETs on the basis of the type of damage induced, it is not possible to infer from these studies specific conclusions valid for incorporated radionuclides alone. The biological dosimetry assays and EPR techniques proved to be most applicable in cases when the radionuclides are almost homogeneously distributed in the body. No compelling evidence was obtained in other cases of extremely inhomogeneous distribution. Retrospective dosimetry needs to be optimized and further developed in order to be able to deal with real exposure cases, where a mixture of both external and internal exposures will be encountered most of the times.


Asunto(s)
Radiación Ionizante , Radiometría/métodos , Animales , Espectroscopía de Resonancia por Spin del Electrón , Humanos , Radioisótopos/farmacocinética
2.
Clin Radiol ; 74(10): 816.e9-816.e17, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31375261

RESUMEN

AIM: To determine cumulative scan frequencies and estimate lens dose for paediatric computed tomography (CT) head examinations in the context of potential cataract risk. MATERIALS AND METHODS: The cumulative number of head-region CT examinations among a cohort of 410,997 children and young adults who underwent CT in the UK between 1985 and 2014 was calculated. Images from a sample of these head examinations (n=668) were reviewed to determine the level of eye inclusion. Lens dose per scan was estimated using the computer program, NCICT V1.0, for different levels of eye inclusion and exposure settings typical of past and present clinical practice. RESULTS: In total 284,878 patients underwent 448,108 head-region CT examinations. The majority of patients (72%) had a single recorded head-region examination. A small subset (∼1%, n=2,494) underwent ≥10 examinations, while 0.1% (n=387) underwent ≥20. The lens was included within the imaged region for 57% of reviewed routine head examinations. In many cases, this appeared to be intentional, i.e. protocol driven. In others, there appeared to have been an attempt to exclude the eyes through gantry angulation. Estimated lens doses were 20-75 mGy (mean: 47 mGy) where the eye was fully included within the examination range and 2-7 mGy (mean: 3.1 mGy) where the lens was fully excluded. Potential cumulative lens doses ranged from ∼3 mGy to ∼4,700 mGy, with 2,335 patients potentially receiving >500 mGy. CONCLUSION: The majority of young people will receive cumulative lens doses well below 500 mGy, meaning the risk of cataract induction is likely to be very small.


Asunto(s)
Cabeza/diagnóstico por imagen , Cristalino/efectos de la radiación , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Adolescente , Catarata/etiología , Catarata/prevención & control , Niño , Preescolar , Estudios de Cohortes , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Posicionamiento del Paciente , Exposición a la Radiación/efectos adversos , Adulto Joven
3.
Radiat Environ Biophys ; 54(4): 433-44, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26205380

RESUMEN

Waterborne radioactive releases into the Techa River from the Mayak Production Association in Russia during 1949-1956 resulted in significant doses to about 30,000 persons who lived in downstream settlements. The residents were exposed to internal and external radiation. Two methods for reconstruction of the external dose are considered in this paper, electron paramagnetic resonance (EPR) measurements of teeth, and fluorescence in situ hybridization (FISH) measurements of chromosome translocations in circulating lymphocytes. The main issue in the application of the EPR and FISH methods for reconstruction of the external dose for the Techa Riverside residents was strontium radioisotopes incorporated in teeth and bones that act as a source of confounding local exposures. In order to estimate and subtract doses from incorporated (89,90)Sr, the EPR and FISH assays were supported by measurements of (90)Sr-body burdens and estimates of (90)Sr concentrations in dental tissues by the luminescence method. The resulting dose estimates derived from EPR to FISH measurements for residents of the upper Techa River were found to be consistent: The mean values vary from 510 to 550 mGy for the villages located close to the site of radioactive release to 130-160 mGy for the more distant villages. The upper bound of individual estimates for both methods is equal to 2.2-2.3 Gy. The EPR- and FISH-based dose estimates were compared with the doses calculated for the donors using the most recent Techa River Dosimetry System (TRDS). The TRDS external dose assessments are based on the data on contamination of the Techa River floodplain, simulation of air kerma above the contaminated soil, age-dependent lifestyles and individual residence histories. For correct comparison, TRDS-based doses were calculated from two sources: external exposure from the contaminated environment and internal exposure from (137)Cs incorporated in donors' soft tissues. It is shown here that the TRDS-based absorbed doses in tooth enamel and muscle are in agreement with EPR- and FISH-based estimates within uncertainty bounds. Basically, this agreement between the estimates has confirmed the validity of external doses calculated with the TRDS.


Asunto(s)
Esmalte Dental/química , Espectroscopía de Resonancia por Spin del Electrón , Hibridación Fluorescente in Situ , Músculo Esquelético/química , Exposición a la Radiación/análisis , Monitoreo de Radiación , Radioisótopos de Estroncio/análisis , Absorción de Radiación , Anciano , Anciano de 80 o más Años , Bioensayo , Femenino , Humanos , Masculino , Liberación de Radiactividad Peligrosa , Residuos Radiactivos/análisis , Reproducibilidad de los Resultados , Federación de Rusia , Sensibilidad y Especificidad , Contaminantes Radiactivos del Agua/análisis , Recuento Corporal Total
4.
Radiat Environ Biophys ; 53(2): 241-54, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24557539

RESUMEN

In the case of a large scale radiation accident high throughput methods of biological dosimetry for population triage are needed to identify individuals requiring clinical treatment. The dicentric assay performed in web-based scoring mode may be a very suitable technique. Within the MULTIBIODOSE EU FP7 project a network is being established of 8 laboratories with expertise in dose estimations based on the dicentric assay. Here, the manual dicentric assay was tested in a web-based scoring mode. More than 23,000 high resolution images of metaphase spreads (only first mitosis) were captured by four laboratories and established as image galleries on the internet (cloud). The galleries included images of a complete dose effect curve (0-5.0 Gy) and three types of irradiation scenarios simulating acute whole body, partial body and protracted exposure. The blood samples had been irradiated in vitro with gamma rays at the University of Ghent, Belgium. Two laboratories provided image galleries from Fluorescence plus Giemsa stained slides (3 h colcemid) and the image galleries from the other two laboratories contained images from Giemsa stained preparations (24 h colcemid). Each of the 8 participating laboratories analysed 3 dose points of the dose effect curve (scoring 100 cells for each point) and 3 unknown dose points (50 cells) for each of the 3 simulated irradiation scenarios. At first all analyses were performed in a QuickScan Mode without scoring individual chromosomes, followed by conventional scoring (only complete cells, 46 centromeres). The calibration curves obtained using these two scoring methods were very similar, with no significant difference in the linear-quadratic curve coefficients. Analysis of variance showed a significant effect of dose on the yield of dicentrics, but no significant effect of the laboratories, different methods of slide preparation or different incubation times used for colcemid. The results obtained to date within the MULTIBIODOSE project by a network of 8 collaborating laboratories throughout Europe are very promising. The dicentric assay in the web based scoring mode as a high throughput scoring strategy is a useful application for biodosimetry in the case of a large scale radiation accident.


Asunto(s)
Cromosomas Humanos/genética , Cromosomas Humanos/efectos de la radiación , Conducta Cooperativa , Internet , Liberación de Radiactividad Peligrosa , Radiometría/métodos , Triaje , Aberraciones Cromosómicas/efectos de la radiación , Humanos , Dosis de Radiación , Factores de Tiempo
5.
J Radiol Prot ; 34(1): 15-29, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24270156

RESUMEN

The ICRP has recently recommended that the occupational exposure limit for the lens of the eye be reduced to 20 mSv in a year, averaged over defined periods of 5 years, with no single year exceeding 50 mSv. There has been concern amongst some groups of individuals, particularly interventional cardiologists and radiologists as well as relevant professional bodies, that implementation of these recommendations into UK law will adversely affect working patterns. However, despite a number of informative European studies, there is currently little UK dosimetry data available upon which judgements can effectively be based. In order to address this knowledge gap, Public Health England has carried out a small, targeted survey of UK lens doses to medical staff undertaking procedures likely to involve the highest levels of radiation exposure. Two out of a total of 61 individuals surveyed had projected annual doses which could be close to 20 mSv, measured outside lead glasses. Use of protective equipment was generally good; however, lead glasses were only used by 9 participants. The results of this survey suggest that compliance with the ICRP recommendations is likely to be possible for most individuals in the UK medical sector.


Asunto(s)
Personal de Salud , Cristalino/efectos de la radiación , Exposición Profesional/estadística & datos numéricos , Salud Pública , Dosis de Radiación , Salud Radiológica , Humanos , Reino Unido
6.
Int J Radiat Biol ; : 1-13, 2024 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-38190433

RESUMEN

PURPOSE: The purpose of this paper is to provide an overview of the methodology used to estimate radiation genetic risks and quantify the risk of hereditary effects as outlined in the ICRP Publication 103. It aims to highlight the historical background and development of the doubling dose method for estimating radiation-related genetic risks and its continued use in radiological protection frameworks. RESULTS: This article emphasizes the complexity associated with quantifying the risk of hereditary effects caused by radiation exposure and highlights the need for further clarification and explanation of the calculation method. As scientific knowledge in radiation sciences and human genetics continues to advance in relation to a number of factors including stability of disease frequency, selection pressures, and epigenetic changes, the characterization and quantification of genetic effects still remains a major issue for the radiological protection system of the International Commission on Radiological Protection. CONCLUSION: Further research and advancements in this field are crucial for enhancing our understanding and addressing the complexities involved in assessing and managing the risks associated with hereditary effects of radiation.

7.
Mutat Res ; 756(1-2): 174-83, 2013 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-23707243

RESUMEN

Mass casualty scenarios of radiation exposure require high throughput biological dosimetry techniques for population triage in order to rapidly identify individuals who require clinical treatment. The manual dicentric assay is a highly suitable technique, but it is also very time consuming and requires well trained scorers. In the framework of the MULTIBIODOSE EU FP7 project, semi-automated dicentric scoring has been established in six European biodosimetry laboratories. Whole blood was irradiated with a Co-60 gamma source resulting in 8 different doses between 0 and 4.5Gy and then shipped to the six participating laboratories. To investigate two different scoring strategies, cell cultures were set up with short term (2-3h) or long term (24h) colcemid treatment. Three classifiers for automatic dicentric detection were applied, two of which were developed specifically for these two different culture techniques. The automation procedure included metaphase finding, capture of cells at high resolution and detection of dicentric candidates. The automatically detected dicentric candidates were then evaluated by a trained human scorer, which led to the term 'semi-automated' being applied to the analysis. The six participating laboratories established at least one semi-automated calibration curve each, using the appropriate classifier for their colcemid treatment time. There was no significant difference between the calibration curves established, regardless of the classifier used. The ratio of false positive to true positive dicentric candidates was dose dependent. The total staff effort required for analysing 150 metaphases using the semi-automated approach was 2 min as opposed to 60 min for manual scoring of 50 metaphases. Semi-automated dicentric scoring is a useful tool in a large scale radiation accident as it enables high throughput screening of samples for fast triage of potentially exposed individuals. Furthermore, the results from the participating laboratories were comparable which supports networking between laboratories for this assay.


Asunto(s)
Aberraciones Cromosómicas/efectos de la radiación , Cromosomas Humanos/efectos de la radiación , Rayos gamma/efectos adversos , Laboratorios/normas , Linfocitos/efectos de la radiación , Monitoreo de Radiación/métodos , Liberación de Radiactividad Peligrosa/prevención & control , Automatización , Radioisótopos de Cobalto , Relación Dosis-Respuesta en la Radiación , Europa (Continente) , Humanos
8.
Hong Kong Med J ; 19(2): 168-73, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23535678

RESUMEN

Dicentric assay is the international gold standard for cytogenetic biodosimetry after radiation exposure, despite being very labour-intensive, time-consuming, and highly expertise-dependent. It involves the identification of centromeres and structure of solid-stained chromosomes and the enumeration of dicentric chromosomes in a large number of first-division metaphases of cultured T lymphocytes. The dicentric yield is used to estimate the radiation exposure dosage according to a statistically derived and predetermined dose-response curve. It can be used for population triage after large-scale accidental over-exposure to ionising radiation or with a view to making clinical decisions for individual patients receiving substantial radiation. In this report, we describe our experience in the establishment of a cytogenetic biodosimetry laboratory in Queen Elizabeth Hospital, Hong Kong. This was part of the contingency plan for emergency measures against radiation accidents at nuclear power stations.


Asunto(s)
Relación Dosis-Respuesta en la Radiación , Dosis de Radiación , Monitoreo de Radiación/métodos , Liberación de Radiactividad Peligrosa/prevención & control , Bioensayo , Cromosomas Humanos/efectos de la radiación , Análisis Citogenético , Femenino , Hong Kong , Humanos , Masculino , Plantas de Energía Nuclear , Radiación Ionizante , Radiometría , Medición de Riesgo
9.
Int J Radiat Biol ; : 1-11, 2023 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-37947483

RESUMEN

PURPOSE: Over the last decade or so, ethical and societal aspects of radiological protection have received increasing attention. This is also reflected in the publications of the International Commission on Radiological Protection (ICRP). The current paper aims at identifying relevant ethical and societal topics which should receive attention in the context of radiological protection for offspring and next generations. MATERIALS AND METHODS: We present a non-comprehensive review of the subject, based on presentation made at an ICRP workshop in Budapest in 2022. We first discuss the ethical values promoted by ICRP, and the application of these values in cases of (potential) pre-conceptual and prenatal radiation exposures. We then consider experience gained after the Fukushima accident indicating particular societal concerns about the health effects of such exposures. RESULTS AND CONCLUSIONS: Beneficence/non-maleficence, prudence, justice and dignity, the "core values" of the system of radiological protection have special roles to play when heritable and/or in utero effects are to be considered. Prudence, in particular, must be taken account of in view of the fact that solid scientific data in humans are largely lacking in this area, and it is necessary to rely on insights from animal experiments as well as theoretical considerations. As regards societal considerations, the perception of risk among (potentially) affected populations needs to be taken seriously. Accountability, transparency, and inclusivity, the "procedural values" promoted by ICRP for the practical implementation of the system of radiological protection play a central role in overcoming skepticism and creating trust. Stakeholder involvement should emphasize cooperation and dialogue, which allows for the joint evaluation of an exposure situation by experts and affected people.

10.
Radiat Res ; 199(6): 556-570, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37018160

RESUMEN

After large-scale radiation accidents where many individuals are suspected to be exposed to ionizing radiation, biological and physical retrospective dosimetry assays are important tools to aid clinical decision making by categorizing individuals into unexposed/minimally, moderately or highly exposed groups. Quality-controlled inter-laboratory comparisons of simulated accident scenarios are regularly performed in the frame of the European legal association RENEB (Running the European Network of Biological and Physical retrospective Dosimetry) to optimize international networking and emergency readiness in case of large-scale radiation events. In total 33 laboratories from 22 countries around the world participated in the current RENEB inter-laboratory comparison 2021 for the dicentric chromosome assay. Blood was irradiated in vitro with X rays (240 kVp, 13 mA, ∼75 keV, 1 Gy/min) to simulate an acute, homogeneous whole-body exposure. Three blood samples (no. 1: 0 Gy, no. 2: 1.2 Gy, no. 3: 3.5 Gy) were sent to each participant and the task was to culture samples, to prepare slides and to assess radiation doses based on the observed dicentric yields from 50 manually or 150 semi-automatically scored metaphases (triage mode scoring). Approximately two-thirds of the participants applied calibration curves from irradiations with γ rays and about 1/3 from irradiations with X rays with varying energies. The categorization of the samples in clinically relevant groups corresponding to individuals that were unexposed/minimally (0-1 Gy), moderately (1-2 Gy) or highly exposed (>2 Gy) was successfully performed by all participants for sample no. 1 and no. 3 and by ≥74% for sample no. 2. However, while most participants estimated a dose of exactly 0 Gy for the sham-irradiated sample, the precise dose estimates of the samples irradiated with doses >0 Gy were systematically higher than the corresponding reference doses and showed a median deviation of 0.5 Gy (sample no. 2) and 0.95 Gy (sample no. 3) for manual scoring. By converting doses estimated based on γ-ray calibration curves to X-ray doses of a comparable mean photon energy as used in this exercise, the median deviation decreased to 0.27 Gy (sample no. 2) and 0.6 Gy (sample no. 3). The main aim of biological dosimetry in the case of a large-scale event is the categorization of individuals into clinically relevant groups, to aid clinical decision making. This task was successfully performed by all participants for the 0 Gy and 3.5 Gy samples and by 74% (manual scoring) and 80% (semiautomatic scoring) for the 1.2 Gy sample. Due to the accuracy of the dicentric chromosome assay and the high number of participating laboratories, a systematic shift of the dose estimates could be revealed. Differences in radiation quality (X ray vs. γ ray) between the test samples and the applied dose effect curves can partly explain the systematic shift. There might be several additional reasons for the observed bias (e.g., donor effects, transport, experimental conditions or the irradiation setup) and the analysis of these reasons provides great opportunities for future research. The participation of laboratories from countries around the world gave the opportunity to compare the results on an international level.


Asunto(s)
Aberraciones Cromosómicas , Liberación de Radiactividad Peligrosa , Humanos , Estudios Retrospectivos , Radiometría/métodos , Bioensayo/métodos , Cromosomas , Relación Dosis-Respuesta en la Radiación
11.
Radiat Res ; 197(1): 92-99, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-33984857

RESUMEN

Lens epithelial cell proliferation and differentiation are naturally well regulated and controlled, a characteristic essential for lens structure, symmetry and function. The effect of ionizing radiation on lens epithelial cell proliferation has been demonstrated in previous studies at high acute doses, but the effect of dose and dose rate on proliferation has not yet been considered. In this work, mice received single acute doses of 0.5, 1 and 2 Gy of radiation, at dose rates of 0.063 and 0.3 Gy/min. Eye lenses were isolated postirradiation at 30 min up until 14 days and flat-mounted. Then, cell proliferation rates were determined using biomarker Ki67. As expected, radiation increased cell proliferation 2 and 24 h postirradiation transiently (undetectable 14 days postirradiation) and was dose dependent (changes were very significant at 2 Gy; P = 0.008). A dose-rate effect did not reach significance in this study (P = 0.054). However, dose rate and lens epithelial cell region showed significant interactions (P < 0.001). These observations further our mechanistic understanding of how the lens responds to radiation.


Asunto(s)
Cristalino/efectos de la radiación , Animales , Diferenciación Celular/efectos de la radiación , Proliferación Celular/efectos de la radiación , Relación Dosis-Respuesta en la Radiación , Células Epiteliales , Femenino , Humanos , Ratones Endogámicos C57BL , Dosis de Radiación , Exposición a la Radiación , Radiación Ionizante
12.
Radiat Res ; 197(1): 36-42, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-33652474

RESUMEN

Epidemiological studies suggest an increased incidence and risk of cataract after low-dose (<2 Gy) ionizing radiation exposures. However, the biological mechanism(s) of this process are not fully understood. DNA damage and repair are thought to have a contributing role in radiation-induced cataractogenesis. Recently we have reported an inverse dose-rate effect, as well as the low-dose response, of DNA damage and repair in lens epithelial cells (LECs). Here, we present further initial findings from two mutated strains (Ercc2+/- and Ptch1+/-) of mice, both reportedly susceptible to radiation-induced cataract, and their DNA damage and repair response to low-dose and low-dose-rate gamma rays. Our results support the hypothesis that the lens epithelium responds differently to radiation than other tissues, with reported radiation susceptibility to DNA damage not necessarily translating to the LECs. Genetic predisposition and strain(s) of mice have a significant role in radiation-induced cataract susceptibility.


Asunto(s)
Catarata/etiología , Daño del ADN/efectos de la radiación , Cristalino/efectos de los fármacos , Animales , Células Epiteliales , Rayos gamma , Humanos , Ratones , Receptor Patched-1/metabolismo , Exposición a la Radiación , Proteína de la Xerodermia Pigmentosa del Grupo D/metabolismo
13.
Radiat Res ; 197(1): 57-66, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-33984859

RESUMEN

Recent epidemiological findings and reanalysis of historical data suggest lens opacities resulting from ionizing radiation exposures are likely induced at lower doses than previously thought. These observations have led to ICRP recommendations for a reduction in the occupational dose limits for the eye lens, as well as subsequent implementation in EU member states. The EU CONCERT LDLensRad project was initiated to further understand the effects of ionizing radiation on the lens and identify the mechanism(s) involved in radiation-induced cataract, as well as the impact of dose and dose-rate. Here, we present the results of a long-term study of changes to lens opacity in male and female adult mice from a variety of different genetic (radiosensitive or radioresistant) backgrounds, including mutant strains Ercc2 and Ptch1, which were assumed to be susceptible to radiation-induced lens opacities. Mice received 0.5, 1 and 2 Gy 60Co gamma-ray irradiation at dose rates of 0.063 and 0.3 Gy min-1. Scheimpflug imaging was used to quantify lens opacification as an early indicator of cataract, with monthly observations taken postirradiation for an 18-month period in all strains apart from 129S2, which were observed for 12 months. Opacification of the lens was found to increase with time postirradiation (with age) for most mouse models, with ionizing radiation exposure increasing opacities further. Sex, dose, dose rate and genetic background were all found to be significant contributors to opacification; however, significant interactions were identified, which meant that the impact of these factors was strain dependent. Mean lens density increased with higher dose and dose rate in the presence of Ercc2 and Ptch1 mutations. This project was the first to focus on low (<1 Gy) dose, multiple dose rate, sex and strain effects in lens opacification, and clearly demonstrates the importance of these experimental factors in radiobiological investigations on the lens. The results provide insight into the effects of ionizing radiation on the lens as well as the need for further work in this area to underpin appropriate radiation protection legislation and guidance.


Asunto(s)
Catarata/etiología , Animales , Femenino , Antecedentes Genéticos , Humanos , Cristalino/efectos de la radiación , Masculino , Ratones , Ratones Endogámicos BALB C , Ratones Endogámicos C57BL , Exposición Profesional , Receptor Patched-1/metabolismo , Dosis de Radiación , Exposición a la Radiación , Radiación Ionizante , Proteína de la Xerodermia Pigmentosa del Grupo D/metabolismo
14.
Radiat Res ; 195(3): 253-264, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33347576

RESUMEN

With the use of ionizing radiation comes the risk of accidents and malevolent misuse. When unplanned exposures occur, there are several methods which can be used to retrospectively reconstruct individual radiation exposures; biological methods include analysis of aberrations and damage of chromosomes and DNA, while physical methods rely on luminescence (TL/OSL) or EPR signals. To ensure the quality and dependability of these methods, they should be evaluated under realistic exposure conditions. In 2019, EURADOS Working Group 10 and RENEB organized a field test with the purpose of evaluating retrospective dosimetry methods as carried out in potential real-life exposure scenarios. A 1.36 TBq 192Ir source was used to irradiate anthropomorphic phantoms in different geometries at doses of several Gy in an outdoor open-air geometry. Materials intended for accident dosimetry (including mobile phones and blood) were placed on the phantoms together with reference dosimeters (LiF, NaCl, glass). The objective was to estimate radiation exposures received by individuals as measured using blood and fortuitous materials, and to evaluate these methods by comparing the estimated doses to reference measurements and Monte Carlo simulations. Herein we describe the overall planning, goals, execution and preliminary outcomes of the 2019 field test. Such field tests are essential for the development of new and existing methods. The outputs from this field test include useful experience in terms of planning and execution of future exercises, with respect to time management, radiation protection, and reference dosimetry to be considered to obtain relevant data for analysis.


Asunto(s)
Dosis de Radiación , Monitoreo de Radiación/métodos , Radiación Ionizante , Humanos , Radioisótopos de Iridio/efectos adversos , Método de Montecarlo , Fantasmas de Imagen , Exposición a la Radiación/efectos adversos , Protección Radiológica , Radiometría/métodos
15.
Radiat Prot Dosimetry ; 194(1): 42-56, 2021 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-33989429

RESUMEN

Since 2012, the European Radiation Dosimetry Group (EURADOS) has developed its Strategic Research Agenda (SRA), which contributes to the identification of future research needs in radiation dosimetry in Europe. Continued scientific developments in this field necessitate regular updates and, consequently, this paper summarises the latest revision of the SRA, with input regarding the state of the art and vision for the future contributed by EURADOS Working Groups and through a stakeholder workshop. Five visions define key issues in dosimetry research that are considered important over at least the next decade. They include scientific objectives and developments in (i) updated fundamental dose concepts and quantities, (ii) improved radiation risk estimates deduced from epidemiological cohorts, (iii) efficient dose assessment for radiological emergencies, (iv) integrated personalised dosimetry in medical applications and (v) improved radiation protection of workers and the public. This SRA will be used as a guideline for future activities of EURADOS Working Groups but can also be used as guidance for research in radiation dosimetry by the wider community. It will also be used as input for a general European research roadmap for radiation protection, following similar previous contributions to the European Joint Programme for the Integration of Radiation Protection Research, under the Horizon 2020 programme (CONCERT). The full version of the SRA is available as a EURADOS report (www.eurados.org).


Asunto(s)
Monitoreo de Radiación , Protección Radiológica , Europa (Continente) , Humanos , Dosis de Radiación , Radiación Ionizante , Radiometría
16.
Sci Rep ; 11(1): 9756, 2021 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-33963206

RESUMEN

Large-scale radiation emergency scenarios involving protracted low dose rate radiation exposure (e.g. a hidden radioactive source in a train) necessitate the development of high throughput methods for providing rapid individual dose estimates. During the RENEB (Running the European Network of Biodosimetry) 2019 exercise, four EDTA-blood samples were exposed to an Iridium-192 source (1.36 TBq, Tech-Ops 880 Sentinal) at varying distances and geometries. This resulted in protracted doses ranging between 0.2 and 2.4 Gy using dose rates of 1.5-40 mGy/min and exposure times of 1 or 2.5 h. Blood samples were exposed in thermo bottles that maintained temperatures between 39 and 27.7 °C. After exposure, EDTA-blood samples were transferred into PAXGene tubes to preserve RNA. RNA was isolated in one laboratory and aliquots of four blinded RNA were sent to another five teams for dose estimation based on gene expression changes. Using an X-ray machine, samples for two calibration curves (first: constant dose rate of 8.3 mGy/min and 0.5-8 h varying exposure times; second: varying dose rates of 0.5-8.3 mGy/min and 4 h exposure time) were generated for distribution. Assays were run in each laboratory according to locally established protocols using either a microarray platform (one team) or quantitative real-time PCR (qRT-PCR, five teams). The qRT-PCR measurements were highly reproducible with coefficient of variation below 15% in ≥ 75% of measurements resulting in reported dose estimates ranging between 0 and 0.5 Gy in all samples and in all laboratories. Up to twofold reductions in RNA copy numbers per degree Celsius relative to 37 °C were observed. However, when irradiating independent samples equivalent to the blinded samples but increasing the combined exposure and incubation time to 4 h at 37 °C, expected gene expression changes corresponding to the absorbed doses were observed. Clearly, time and an optimal temperature of 37 °C must be allowed for the biological response to manifest as gene expression changes prior to running the gene expression assay. In conclusion, dose reconstructions based on gene expression measurements are highly reproducible across different techniques, protocols and laboratories. Even a radiation dose of 0.25 Gy protracted over 4 h (1 mGy/min) can be identified. These results demonstrate the importance of the incubation conditions and time span between radiation exposure and measurements of gene expression changes when using this method in a field exercise or real emergency situation.


Asunto(s)
Células Sanguíneas/metabolismo , Rayos gamma/efectos adversos , Regulación de la Expresión Génica/efectos de la radiación , Laboratorios , Dosis de Radiación , Exposición a la Radiación , Rayos X/efectos adversos , Relación Dosis-Respuesta en la Radiación , Humanos , Reproducibilidad de los Resultados
17.
Ann ICRP ; 49(1_suppl): 32-44, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32907341

RESUMEN

Medical exposures form the largest manmade contributor to total ionising radiation exposure of the UK population. In recent years, new technologies have been developed to improve treatment and prognosis of individuals treated with radiation for diseases such as cancer. However, there is evidence of public, patient, and medical professional concern that radiation protection regulations and practices, as well as understanding of potential long-term adverse health effects of radiation exposure (in the context of other health risks), have not always 'kept pace' with technological developments in this field. This is a truly complex, multi-disciplinary problem for the modern world.The 'Radiation Theme' of the Public Health England and Newcastle University Health Protection Research Unit on 'Chemical and Radiation Threats and Hazards' is addressing this need, with a key focus on a genuinely interdisciplinary approach bringing together world-leading epidemiologists, radiation biologists, clinicians, statisticians, and artists. In addition, the project has a strong grounding in public, patient, and medical professional involvement in research. Similarly, the EU-CONCERT-funded LDLensRad project seeks to understand the mechanisms of action of low-dose ionising radiation in the lens of the eye, and the potential contribution to the development of cataract - in contemporary research, such projects will only be considered successful when they make use of expertise from a variety of fields and when they are able to demonstrate that the outputs are not only of benefit to society, but that society understands and welcomes the benefits. Finally, successful engagement, training, and retention of early career scientists within this field is crucial for sustainability of the research. Herein, the contribution of embedded interdisciplinary working, stakeholder involvement, and training of early career scientists to recent advancements in the field of medical (and wider) radiation protection research is discussed and considered.


Asunto(s)
Investigación Interdisciplinaria/estadística & datos numéricos , Protección Radiológica/métodos , Radiación Ionizante , Participación de los Interesados , Humanos , Protección Radiológica/normas
18.
Radiat Res ; 172(1): 1-9, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19580502

RESUMEN

The lens of the eye is recognized as one of the most radiosensitive tissues in the human body, and it is known that cataracts can be induced by acute doses of less than 2 Gy of low-LET ionizing radiation and less than 5 Gy of protracted radiation. Although much work has been carried out in this area, the exact mechanisms of radiation cataractogenesis are still not fully understood. In particular, the question of the threshold dose for cataract development is not resolved. Cataracts have been classified as a deterministic effect of radiation exposure with a threshold of approximately 2 Gy. Here we review the combined results of recent mechanistic and human studies regarding induction of cataracts by ionizing radiation. These studies indicate that the threshold for cataract development is certainly less than was previously estimated, of the order of 0.5 Gy, or that radiation cataractogenesis may in fact be more accurately described by a linear, no-threshold model.


Asunto(s)
Catarata/etiología , Traumatismos por Radiación/etiología , Factores de Edad , Animales , Aviación , Catarata/epidemiología , Accidente Nuclear de Chernóbil , Humanos , Cristalino/efectos de la radiación , Armas Nucleares , Exposición Profesional , Dosis de Radiación , Traumatismos por Radiación/epidemiología , Radioterapia/efectos adversos , Factores de Riesgo , Sobrevivientes
19.
Cytogenet Genome Res ; 122(3-4): 292-6, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-19188698

RESUMEN

Telomeres are specialised structures at the ends of mammalian chromosomes with many unique properties. Recombinational events at telomeres are more frequent than in the remainder of the genome by several orders of magnitude. This study examined the influence of telomerase status and telomere length on genome-wide recombination assessed by genomic sister chromatid exchange (G-SCE). Telomerase deficiency per se appears to increase G-SCE frequencies in splenocytes but as telomeres shorten through subsequent generations of mTerc(-/-) mice this increase is progressively lost. Telomerase status and telomere length also influences the induction of G-SCE by UV light. Even when mitotic recombination is affected by PARP deficiency, mTerc and telomere length interact to further affect G-SCE frequencies. Taken together the data presented here demonstrate that telomerase status and telomere length can affect recombination frequencies genome-wide.


Asunto(s)
Mitosis/genética , ARN/genética , Recombinación Genética , Intercambio de Cromátides Hermanas/genética , Telomerasa/genética , Telómero/genética , Análisis de Varianza , Animales , Ciclo Celular , Regulación Enzimológica de la Expresión Génica , Frecuencia de los Genes , Genotipo , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Poli(ADP-Ribosa) Polimerasas/deficiencia , Poli(ADP-Ribosa) Polimerasas/genética , Bazo/citología , Bazo/enzimología , Telomerasa/deficiencia , Telómero/ultraestructura
20.
Radiat Prot Dosimetry ; 131(3): 287-96, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18550513

RESUMEN

The aim of this study was to investigate whether radiofrequency (RF) fields characteristic of mobile phones at non-thermal levels can induce apoptosis in murine neuroblastoma (N2a) cells in both proliferating and differentiated states. Cells were exposed continuously for 24 h to one of the three 935-MHz RF signals: global system for mobile communication (GSM) basic, GSM talk and a continuous wave, unmodulated signal; all at a specific energy absorption rate of 2 W kg(-1). The measured increase in temperature of the cells due to the RF fields was around 0.06 degrees C. At a number of time points between 0 and 48 h post-exposure, the cells were assessed for apoptosis under a fluorescence microscope using three independent assays: Annexin V, caspase activation and in situ end-labelling. No statistically significant differences in apoptosis levels were observed between the exposed and sham-exposed cells using the three assays at any time point post-exposure. These data suggest that RF exposures, characteristic of GSM mobile phones, do not significantly affect the apoptosis levels in proliferating and differentiated murine neuroblastoma cell line N2a.


Asunto(s)
Apoptosis/efectos de la radiación , Diferenciación Celular/efectos de la radiación , Proliferación Celular/efectos de la radiación , Neuroblastoma/patología , Ondas de Radio , Animales , Anexina A5/metabolismo , Caspasas/metabolismo , Línea Celular Tumoral , Teléfono Celular , Relación Dosis-Respuesta en la Radiación , Activación Enzimática/efectos de la radiación , Ratones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA